Professional Documents
Culture Documents
Lubricating Oil System: Instalação Propulsora Do Navio Ro-Ro Pax Ferry
Lubricating Oil System: Instalação Propulsora Do Navio Ro-Ro Pax Ferry
1
Extracto de: ERS_5000_2xMAN_BW_8L32-40_RoPax_Ferry_Trainee_Manual
ERS_5000_2xMAN_BW_8L32-40_RoPax_Ferry
SYSTEM CONTENTS
• Click the menu item ME Port Lube Oil System (or ME Stbd Lube Oil System) of
the page SYS to open the display for local control of the ME lubricating system.
SIMULADOR DE MÁQUINAS MARÍTIMAS
INSTITUTO DE ENGENHARIA E CIÊNCIAS DO MAR
UNIVERSIDADE TÉCNICA DO ATLÂNTICO
2
Extracto de: ERS_5000_2xMAN_BW_8L32-40_RoPax_Ferry_Trainee_Manual
• ME Port LO Stand-by Pump (3): electrical, 120 m3\h x4.5 bar before ME;
• ME Port LO Automatic Filter (4): clogging is presented by increasing red sections
on the indicator body;
• Bunker Station PORT and STBD;
• LO Transfer pump (5): 2 m3/h x 2 bar;
• LO Storage Tank ;
• ME Port LO Service Tank ;
• Leakage Oil Collecting Tank ;
• LO Purifier unit (1650 L/hour) with Purifiers Operating water tank;
• LO Purifier Feed Pump (6): 2 m3/h x 2 bar;
• ME Port LO cooler .
• Pipelines with valves, filters, measuring gauges.
Prof. Manuel E. Fortes T. Almeida 1-5
circuit breaker;
UNIVERSIDADE TÉCNICA DO ATLÂNTICO
ME Stbd Cylinder Pump on No.2 AC440V FEEDER PANEL (use menu item MSB
Feeder Panel 440V of the page MSB) by ME STBD CYL LO PUMP STARTER
circuit breaker.
CONNECTIONS CONTROLS ON DIAGRAM
• Make Up • ME PS Pressure Control Valve (7);
• To HFO Purifiers
• To MDO Purifiers • Two Change Over Filters Valve (4)
• To LO Purifier 2 (for Stbd system, to Purifier 1) in Duplex Filter unit.
• To Sludge Tank • Temp Set controller for the heater
• Thermal Oil Inlet unit in the LO and Sludge tanks; use
• Thermal Oil Outlet small arrow buttons to set required
• To ME Port LO Service Tank content temperature in the tank.
• To Sludge Pump
• To/From LT Cooling Water System
Prof. Manuel E. Fortes T. Almeida 1-6
3
Extracto de: ERS_5000_2xMAN_BW_8L32-40_RoPax_Ferry_Trainee_Manual
in MSB position;
From CMS mimic – selector switch on GSP is in
CMS position.
• Click the menu item LO, Sludge Pump LOP of the page
MER1 to open the LO PUMP LOCAL CONTROL PANEL.
• Click the menu item MSB PS GSP Panel 1 of the page MSB to
open the ME PORT ST-BY LO PUMP panel.
• Click the menu item MSB SB GSP Panel 1 of the page MSB to
open the ME STBD ST-BY LO PUMP panel.
• Switch the power supply 440 V for LO TRANSFER PUMP on
No.2 AC440V FEEDER PANEL (use menu item MSB Feeder
Panel 440V of the page MSB) by LO TRANSFER PUMP
STARTER circuit breaker.
LO PURIFIERS OPERATION
• Click the menu item LO Purifiers LOP of the page MER1 to open the
display with identical LO PURIFIER № 1 and LO PURIFIER № 2
panels.
SIMULADOR DE MÁQUINAS MARÍTIMAS
4
Extracto de: ERS_5000_2xMAN_BW_8L32-40_RoPax_Ferry_Trainee_Manual
LO PURIFIERS OPERATION
• The separator separates water and solid particles from LO located in
LO service tanks and transfers the separated LO back to service
tanks.
operation.
5
Extracto de: ERS_5000_2xMAN_BW_8L32-40_RoPax_Ferry_Trainee_Manual
LO SEPARATORS OPERATION
• Separators 1 and 2 in the simulator are intended for the LO purification or
clarification, if necessary.
• Separator 3 in the simulator is intended for the clarification of the
LO SEPARATORS OPERATION
• Click the START FEED PUMP button
on the separator panel.
• When the separator is filled with fuel, the
SIMULADOR DE MÁQUINAS MARÍTIMAS
6
Extracto de: ERS_5000_2xMAN_BW_8L32-40_RoPax_Ferry_Trainee_Manual
LO SEPARATORS OPERATION
• Click the Process START button on the controller display. When the
separator runs, the RUN LED indicator to the left of the display
illuminates; the process is Displayed on the screen:
• The Separator Time timer displays the
in the simulator. The F1, F2, F3, F4 menu control buttons, and the
UNIVERSIDADE TÉCNICA DO ATLÂNTICO
7
Extracto de: ERS_5000_2xMAN_BW_8L32-40_RoPax_Ferry_Trainee_Manual
9. Turn on the heating (“HEATING” button) and set the required product
temperature (“SET POINT, oC” controller).
SIMULADOR DE MÁQUINAS MARÍTIMAS
10. Supply the operating water for water lock – “OPER. WATER” button and the
INSTITUTO DE ENGENHARIA E CIÊNCIAS DO MAR
UNIVERSIDADE TÉCNICA DO ATLÂNTICO
bowl is filled with water until the water appears in the indicator (peep-hole) in the
water drain line.
11. The separator bowl is filled with fuel - “FLOW” valve opens slowly to supply the
product to the separator (check the required fuel temperature before).
12. The product pressure at the separator outlet (“BACK RESSURE”) is controlled
with the aid of “SET POINT, bar” controller.
13. If the waterlock is broken because of the high back pressure, it is necessary to
reduce the back pressure by 0,5-1 bars and/or to decrease the fuel feed. Safety
solenoid valve is opened if back pressure more than 1 bar and closed if back
pressure less then 0,8 bar or in emergency, if sludge or water will appeared in
separator outlet (product discharge line).
8
Extracto de: ERS_5000_2xMAN_BW_8L32-40_RoPax_Ferry_Trainee_Manual
17. Set the time of removing the sludge from the separator bowl – the time is
set by using “TIME, min” controller (in “AUTO” mode).
18. Check the separation quality – water content in the product before/after
the separator or the content of solid particles. It’s simulated by “WATER
CONTENTS, % – INLET/OUTLET” and “IMPURITY, ppm –
INLET/OUTLET” displays.
19. Check the separator operating parameters by using the indicators on the
control panels.
5. Supply operating water – “OPER. WATER” button. The bowl is filled with
water and is washed.
6. Empty the bowl. Operations can be repeated several times depending on how
dirty the separator is.
STOPPING THE SEPARATOR
1. The separator operates in “AUTO” mode.
2. Empty the bowl (“DISCHARGE” button).
3. Switch the separator to “MANUAL” mode.
4. Cut the water supply to the separator.
5. Stop the separator drive electric motor (“STOP” button).
6. Brake the separator (“BRAKE” button).
7. In emergencies, use “EMERGENCY STOP” button.
Prof. Manuel E. Fortes T. Almeida 1 - 18