Separator sizing
Considerations in separator sizes is important during design. The liquid capacity of most separators is sized to provide enough retention time to allow gas bubbles to form and
separate out.

Contents
Separator design basics
Settling theory
Horizontal separators
Vertical vessels
Drop/bubble sizes
Retention time
Horizontal vessels
Vertical vessels
Demister sizing
Seam to seam length
Horizontal Vessels
Vertical vessels
Nozzle sizing
Examples of separator sizing
Example 1: vertical two-phase separator with a mesh pad demister given values
Example 2: Horizontal two phase separator
Example 3: Vertical three phase separator
Drag coefficients
Nomenclature
Subscripts
References
Noteworthy papers in OnePetro
External links

https://petrowiki.spe.org/Separator_sizing#Retention_time 1/21
17/04/2021 Separator sizing - PetroWiki

See also
Category

Separator design basics


Separators are typically sized by the droplet settling theory or retention time for the liquid phase. For illustration purpose, a general procedure based on retention time
appraoch is as follows

1. Estimate overall volume based on the retention time and expected separation performance for each phase, and the major factors needed to be considered include:

Expected perforamance
Overall through put
Composition of incoming fluids
Intensity of emulsion
Retention time of each individal phase
Types of vessel and internals
levels and alarms
2. Determination of gas cross-sectional area based on settling theory or empirical correlations, and the other factors include

Expected liquid carry-over rate


Avialable mist eliminator
Mean velocity of gas flow
3. Determine oil cross-sectional area based on settling theory or empirical correlations by following similar procedure in Steps 1 and 2.

4. Determine water cross-sectional area based on settling theory or empirical correlations by following similar procedure in Steps 1 and 2.

5. Determine vessel diameter based on cross-sectional area for each phase

6. Determine vessel length to meet the required retention time for all phases

7. Select inlet device and iterate.

8. Evaluation of separation performance for a specific applocation. .

Settling theory

https://petrowiki.spe.org/Separator_sizing#Retention_time 2/21
17/04/2021 Separator sizing - PetroWiki

In gravity settling, the dispersed drops/bubbles will settle at a velocity determined by equating the gravity force on the drop/bubble with the drag force caused by its motion
relative to the continuous phase.

In horizontal vessels, a simple ballistic model can be used to determine a relationship between vessel length and diameter. In vertical vessels, settling theory results in a
relation for the vessel diameter.

Horizontal separators
Droplet settling theory, using a ballistic model, results in the relationship shown in Eq. 1. For liquid drops in gas phase

................(1)

where

d = vessel internal diameter, in.


dm = drop diameter, μm
hg = gas-phase space height, in.
Fg = fractional gas cross-sectional area
Leff = effective length of the vessel where separation occurs, ft
T = operating temperature, °R
Qg = gas flow rate, MMscf/D
P = operating pressure, psia
Z = gas compressibility
ρl = liquid density, lbm/ft3
ρg = gas density, lbm/ft3
CD = drag coefficient. (See below for calculation)

For bubbles or liquid drops in liquid phase:

................(2)

where

dm = bubble or drop diameter, μm

https://petrowiki.spe.org/Separator_sizing#Retention_time 3/21
17/04/2021 Separator sizing - PetroWiki

hc = continuous liquid-phase space height, in.


Fc = fractional continuous-phase cross-sectional area
ρd = dispersed liquid-phase density, lbm/ft3
ρc = continuous liquid-phase density, lbm/ft3
Qc = continuous liquid-phase flow rate, B/D.

For low Reynolds number flow, Eq. 3 can be further reduced to

................(3)

where

trc = continuous-phase retention time, minutes


μc = continuous-phase dynamic viscosity, cp
Δγ = specific gravity difference (heavy/light) of continuous and dispersed phases.

Vertical vessels
Settling theory results in the following relationship. For liquid drops in gas phase,

................(4)

For bubbles or liquid drops in liquid phase,

................(5)

Assuming low Reynolds number flow, Eq. 5 can be further reduced to

................(6)

Drop/bubble sizes
https://petrowiki.spe.org/Separator_sizing#Retention_time 4/21
17/04/2021 Separator sizing - PetroWiki

If drop or bubble removal is being used for sizing, consult Table 1 for guidelines. Sizing the water phase by oil-drop removal is usually not effective. The water effluent quality
is more likely dictated by the added chemicals. Hence, the water-phase volume is typically determined by a retention time, based on experience.

Table 1

The oil drops to be removed from the gas stream also depend upon the downstream equipment. Flare scrubbers are typically designed for removal of drops that are a few
hundred microns in size.

Retention time

Horizontal vessels
The relationship of vessel diameter and length is given by Eq. 7.

................(7)

where

tro = oil retention time, minutes


trw = water-retention time, minutes
Qo = oil flow rate, B/D

https://petrowiki.spe.org/Separator_sizing#Retention_time 5/21
17/04/2021 Separator sizing - PetroWiki

Qw = water flow rate, B/D


Fl = fraction of vessel cross-sectional area filled by liquid.

Vertical vessels
Similarly for vertical vessels, the relationship of vessel diameter and liquid pad heights is given by Eq. 8.

................(8)

where

ho = oil pad height, in.


hw = water pad height, in.

Demister sizing
As discussed previously, many types of demisters are limited by a maximum velocity given by

................(9)

where

Kd = demister capacity factor, ft/sec and depends upon the demister type
Vm = maximum velocity, ft/sec
ρL = liquid density, lbm/ft3
ρg = gas density, lbm/ft3

For horizontal vessels, the required demister area (Ad) is given by

................(10)

https://petrowiki.spe.org/Separator_sizing#Retention_time 6/21
17/04/2021 Separator sizing - PetroWiki

................(11)

For vertical vessels, Eq. 11 is also valid. The vessel diameter is then obtained as

................(12)

For demisters (horizontal or vertical vessels) sealed in a gas box, in addition to the demister area, some height must be maintained between the bottom of the demister and the
highest liquid level for the demister to drain. A pressure drop exists across the demister. If the liquid level is too high, the demister will not drain, and liquid siphoning can
occur. A small hole is sometimes drilled into the drainpipe as a siphon breaker.

When using settling theory or demister sizing in horizontal vessels, one should also consider the gas velocity for re-entrainment. Too high of a gas velocity will result in liquid
re-entrainment from the liquid surface, which may flood the demister and cause carryover. Typical gas velocities for re-entrainment are shown in Table 2.

Table 2

Seam to seam length

https://petrowiki.spe.org/Separator_sizing#Retention_time 7/21
17/04/2021 Separator sizing - PetroWiki

Horizontal Vessels
The seam-to-seam length, Lss, for the horizontal vessel should be determined from the geometry once a diameter and effective length have been determined. Length must be
allotted for inlet devices, gas demisters, and coalescers. For screening purposes, the following approximations can be used.

................(13)

The ratio of length to diameter is typically in the 3 to 5 range.

Vertical vessels
The seam-to-seam length of the vertical vessel should be determined from the geometry, once a diameter and height of liquid volume are known. Allowance must be made for:

the inlet nozzle


space above the liquid level
gas separation section
mist extractor
for any space below the water outlet as shown in Fig. 1

https://petrowiki.spe.org/Separator_sizing#Retention_time 8/21
17/04/2021 Separator sizing - PetroWiki

Fig. 1—Approximate shell length for vertical


vessels (courtesy of CDS Separation Technologies
Inc.).

For screening purposes, the following approximations can be used, where d is the vessel diameter).

................(14)

The ratio of height to diameter is typically in the 3 to 5 range for two-phase separators. For three-phase separators, the ratio is in the 1.5 to 3 range.

Additional consideration should be given for installation of the internals as well as man-way access. In glycol dehydration towers, a man-way is typically installed above the
packing/trays and the demister. Access space must be allotted for installation of the equipment.

Nozzle sizing
Nozzles are generally sized by momentum or velocities. Table 3 gives guidelines that can be used for sizing nozzles, where ρm is the bulk density and Vm the bulk velocity.

https://petrowiki.spe.org/Separator_sizing#Retention_time 9/21
17/04/2021 Separator sizing - PetroWiki

Table 3

In addition, the API RP14E[1] on erosion velocity should be included. This relationship is also given by an inlet momentum criterion as ρmVm2 = C2, where C is given as 100
for continuous service and 125 for intermittent service. The value of C can also vary with pipe material, solids loading, and service. See the chapter on Piping and Pipelines in
this section of the Handbook. Vortex breakers are generally required on the liquid outlets. These are typically perpendicular plates, as shown in Fig. 2.

Fig. 2—Typical vortex breaker (courtesy of CDS


Separation Technologies Inc.).

https://petrowiki.spe.org/Separator_sizing#Retention_time 10/21
17/04/2021 Separator sizing - PetroWiki

Examples of separator sizing

Example 1: vertical two-phase separator with a mesh pad demister given values
The given values for Example 1 are listed next.

Gas rate 10 MMscf/D


Gas specific gravity 0.6
Gas z-factor 0.84
Gas density 3.7 lbm/ft3
Oil rate 2,000 B/D
Oil density 50 lbm/ft3
Operating pressure 1,000 psia
Operating temperature 60°F
OperMesh pad K-factor 0.35 ft/sec
Mesh pad thickness 6 in.
Liquid-retention time 1 minute
Inlet nozzle 4 in.

Step 1. Calculate the required mesh-pad area with Eq. 10. This mesh area will result in a vessel internal diameter of 15 in.

Step 2. Calculate the height for liquid retention time with Eq. 2.13. ho = 74 in.

Step 3. Compute seam-to-seam length with Eq. 9.

The Leff/D (D = d/12) is 9.2 and is larger than the typical 3 to 5 range. Therefore, the internal diameter must be increased to reduce the Leff/D ratio. Table 4 shows Leff/D for
three different vessel IDs. A 24-in. ID vessel has the appropriate Leff/D ratio. The selected vessel would then be 24 in. × 8 ft SS tall (after rounding up the height).

https://petrowiki.spe.org/Separator_sizing#Retention_time 11/21
17/04/2021 Separator sizing - PetroWiki

Table 4

The mesh pad can be installed in two ways, if the 1.15 ft 2 is to be maintained. One, a full-diameter mesh pad can be installed with a blanking annular plate on top. Two, a
cylindrical box with a 15-in. diameter can be installed around the gas outlet.

Example 2: Horizontal two phase separator


Size a horizontal separator to remove 100 μm drops in the gas phase.

Given Values. The given values for Example 2 are listed next:

https://petrowiki.spe.org/Separator_sizing#Retention_time 12/21
17/04/2021 Separator sizing - PetroWiki

Gas rate 10 MMscf/D


Gas specific gravity 0.6
Gas z-factor 0.84

Gas density 3.7 lbm/ft3


Gas viscosity 0.012 cp
Oil rate 2,000 B/D

Oil density 50 lbm/ft3


Operating pressure 1,000 psia
Operating temperature 60°F
Mesh pad K-factor 0.35 ft/sec
Mesh pad thickness 6 in.
Liquid retention time 1 minute
Inlet nozzle 4 in.
Vessel fill 50% (Therefore, Fg = 0.5 and hg = 0.5d.)

Step 1. Calculate vessel diameter and length with Eq. 1 for gas capacity.

................(15)

Assume hg = 0.5 d so that Fg = 0.5.

................(16)

From Appendix A, using a gas viscosity of 0.012 cp, CD = 1.42.

................(17)

https://petrowiki.spe.org/Separator_sizing#Retention_time 13/21
17/04/2021 Separator sizing - PetroWiki

................(18)

Step 2. Calculate Leff and Lss = Leff + d/12 for different values of d.

Step 3. Calculate the vessel diameter and length for liquid retention time with Eq. 7.

Step 4. Calculate Leff and Lss = Leff + d/12 for different values of d.

Step 5. Select vessel that satisfies both gas and liquid capacity.

A comparison of Tables 5 and 6 shows that the liquid capacity is the dominant parameter. Hence, a 24-in. × 6.6-ft vessel is sufficient, as it has a slenderness ratio within the
typical 3 to 5 range. This size should be rounded up to 24 in. × 7 ft.

Table 5 Table 6

Example 3: Vertical three phase separator


Given values. The given values for Example 3 are listed next:

https://petrowiki.spe.org/Separator_sizing#Retention_time 14/21
17/04/2021 Separator sizing - PetroWiki

Gas rate 5 MMscf/D


Gas specific gravity 0.6
Gas z-factor 0.84

Gas density 3.7 lbm/ft3


Oil rate 5,000 B/D

Oil density 50 lbm/ft3


Oil viscosity 10 cp
Water rate 3,000 B/D

Water density 66.8 lbm/ft3


Operating pressure 1,000 psia
Operating temperature 60°F
Liquid-retention time 10 minutes each phase
Inlet nozzle 12 in.
Drop removal from gas 100 μm

Step 1. Calculate vessel diameter based on gas capacity from Eq. 4.

................(19)

From the previous example:

................(20)

................(21)

................(22)

Step 2. Calculate the vessel diameter based on water drop removal from Eq. 6 for a 500-μm drop.

https://petrowiki.spe.org/Separator_sizing#Retention_time 15/21
17/04/2021 Separator sizing - PetroWiki

................(23)

................(24)

At this point, we know that the water-drop removal is the dominant sizing parameter in comparison to the gas capacity.

Step 3. Calculate liquid levels for retention time based on Eq. 8.

................(25)

Table 7 shows liquid levels for different vessel diameters.

Table 7

Step 4. Calculate vessel height from Eq. 13. Vales for Lss are given in Table 8. Values for 12 Lss /d should be in the 1.5 to 3 range.

https://petrowiki.spe.org/Separator_sizing#Retention_time 16/21
17/04/2021 Separator sizing - PetroWiki

Table 8

Step 5. Select a vessel size that satisfies gas capacity, water-drop removal, and liquid-retention time requirements. An 84-in. × 13.4-ft separator satisfies the requirements, so
you would round up to an 84-in. × 13.5-ft vessel. Similarly, a 90-in. × 12.5-ft separator would also be satisfactory.

Drag coefficients
The balance of drag and buoyancy is given as

................(26)

where

VT = terminal velocity, cm/sec;


CD = drag coefficient of drop/bubble;
ρc = continuous phase density, g/cm3;
ρd = dispersed phase density, g/cm3;
g = gravitational constant, 981 cm/sec2;
and
dv = dispersed phase drop/bubble size, cm.

https://petrowiki.spe.org/Separator_sizing#Retention_time 17/21
17/04/2021 Separator sizing - PetroWiki

Eq.26 can be rewritten as

................(27)

where

μc = continuous phase viscosity, g/(cm/sec) = poise,


Re = Reynolds number, VT   dv   ρc /μc,
and
Ar = Archimedes number.
The drag coefficient is a function of the Reynolds number, Re, and is given by a curve-fit of data (up to a Reynolds number of 5,000) from Perry’s Chemical Engineers’
Handbook. [2]

................(28)

The form of Eq. 28 was chosen to allow for an easy solution of Eq. 28 for the Reynolds number as outlined by Darby in Darby[3].

................(29)

The procedure then to calculate the drag coefficient is to calculate the Archimedes number, Ar, as defined in Eq. 27; solve Eq. 29 for the Reynolds number, Re; and solve Eq.
28 for the drag coefficient, CD.

Nomenclature
Ad = required demister area
C = API RP14E erosion constant, (lbm/ft-sec2)1/2
CD = drag coefficient (see Appendix A for calculation)
d = vessel internal diameter, in.
dh = hydraulic diameter, in. (or consistent units for Eq. 11)
dm = bubble or drop diameter, μm
dpp = perpendicular spacing of plates, m
D = vessel diameter, ft
https://petrowiki.spe.org/Separator_sizing#Retention_time 18/21
17/04/2021 Separator sizing - PetroWiki

Fc = fractional continuous-phase cross-sectional area


Fg = fractional gas cross-sectional area
Fl = fraction of vessel cross-sectional area filled by liquid
h = liquid height, in.
hc = continuous liquid-phase space height, in.
hg = gas-phase space height, in.
ho = oil pad height, in.
hw = water pad height, in.
K = mesh capacity factor, m/s or ft/sec
Leff = effective length of the vessel where separation occurs, ft
Lss = seam-to-seam vessel length, ft
P = operating pressure, psia
Qc = continuous liquid-phase flow rate, B/D
Qg = gas flow rate, MMscf/D
Qo = oil flow rate, B/D
Qw = water flow rate, B/D
Re = Reynolds number
T = operating temperature, °R
trc = continuous-phase retention time, minutes
tro = oil-retention time, minutes
trw= water-retention time, minutes
V = bulk velocity, m/sec
Vc = continuous-phase velocity, m/s (or consistent units for Eq. 11 )
Z = gas compressibility
α = inclination angle, degrees
Δγ = specific gravity difference (heavy/light) of continuous and dispersed phases
μc = continuous phase dynamic viscosity, cp
π = constant, 3.14159
ρ = density, kg/m3 or lbm/ft3
ρm = bulk density, kg/m3 or lbm/ft3

https://petrowiki.spe.org/Separator_sizing#Retention_time 19/21
17/04/2021 Separator sizing - PetroWiki

ρc = continuous liquid-phase density, kg/m3 or lbm/ft3


ρd = dispersed liquid-phase density, kg/m3 or lbm/ft3
ρg = gas density, kg/m3 or lbm/ft3
ρl = liquid density, kg/m3 or lbm/ft3
ρo = oil density, kg/m3 or lbm/ft3
ρw = water density, kg/m3 or lbm/ft3
Ar = Archimedes number
CD = drag coefficient of drop/bubble
dv = dispersed phase drop/bubble size, cm
g = gravitational constant, 981 cm/sec2
Re = Reynolds number, VTdvρc/μc
VT = terminal velocity, cm/sec
μc = continuous phase viscosity, g/(cm/sec) = poise
ρc = continuous phase density, g/cm3
ρd = dispersed phase density, g/cm3

Subscripts
m = bulk properties

References
1. API RP14E, Recommended Practice for Design and Installation of Offshore Production Platform Piping Systems, fifth edition. 1991. Washington, DC: API.
2. Perry, R.H. and Green, D.W. 1984. Perry’s Chemical Engineers’ Handbook, fifth edition, 5-66. New York City: McGraw-Hill Book Co.
3. Darby, R. 1996. Determining Settling Rates of Particles. Chemical Engineering (December): 109.

Noteworthy papers in OnePetro


Olotu, C.O. and Osisanya, S. 2013. Development of a User Friendly Computer Program for Designing Conventional Oilfield Separators. SPE-167578-MS Presented at the SPE
Nigeria Annual International Conference and Exhibition, Lagos, Nigeria, 5-7 August. http://dx.doi.org/10.2118/167578-MS (http://dx.doi.org/10.2118/167578-MS).

https://petrowiki.spe.org/Separator_sizing#Retention_time 20/21
17/04/2021 Separator sizing - PetroWiki

Laleh, A.P., Svrcek, W.Y. and Monnery, W. 2013. Computational Fluid Dynamics-Based Study of an Oilfield Separator--Part II: An Optimum Design. Oil and Gas Fac. 2 (1):
52-59. SPE-161036-PA. http://dx.doi.org/10.2118/161036-PA (http://dx.doi.org/10.2118/161036-PA).

External links
Use this section to provide links to relevant material on websites other than PetroWiki and OnePetro

See also
PEH:Oil_and_Gas_Separators

Oil and gas separators

Category
Retrieved from "https://petrowiki.spe.org/index.php?title=Separator_sizing&oldid=48504"

This page was last edited on 6 July 2015, at 10:43.

Copyright 2012-2021, Society of Petroleum Engineers

https://petrowiki.spe.org/Separator_sizing#Retention_time 21/21