You are on page 1of 13

Best Practice / Tips / and

Processes

Copyright © Ciena Corporation 2016. All rights reserved. Confidential & Proprietary. 11
Fiber cut verification and safety procedure


Copyright © Ciena Corporation 2017. All rights reserved. Confidential & Proprietary.
12
Fiber cut verification and safety procedure… cont’d

Copyright © Ciena Corporation 2017. All rights reserved. Confidential & Proprietary.
13
Bi-directional fiber break

Optical Line Fail

Automatic
Shutoff MPB OSC LOS

Tone 1
Tone 2

Laser State
Off Laser State
Off

Tone 2
Optical Line Fail Tone 1

Automatic
MPB OSC LOS Shutoff

Copyright © Ciena Corporation 2017. All rights reserved. Confidential & Proprietary.
14
Uni-directional fiber break

Optical Line Fail

Automatic
Shutoff MPB OSC LOS

Tone 2

Laser State
Off Laser State
Off

Tone 2
Tone 1
Optical Line Fail Tone 1

Automatic
Shutoff

Copyright © Ciena Corporation 2017. All rights reserved. Confidential & Proprietary.
15
Locating Fault

Copyright © Ciena Corporation 2017. All rights reserved. Confidential & Proprietary.
16
Locating fault… Cont’d.

Copyright © Ciena Corporation 2017. All rights reserved. Confidential & Proprietary.
17
Fiber Cleaning and Inspection

1.Lint free cleaning tool, Mfg: Cletop, P/N: 14100500


or equivalent
2.Lint free blue tape replacement reel, Mfg: Cletop,
P/N: 14100700 or equivalent
3.Handheld fiber viewer, Mfg: JDSU, P/N: FBP-HD1
or equivalent
4.High-magnification kit (x400), Mfg: JDSU, P/N:
FBP-S002 or equivalent
5.E-2000 service adapter, Mfg: Diamond, P/N:
1019034
6.OneClick Fiber optic cleaner

Copyright © Ciena Corporation 2017. All rights reserved. Confidential & Proprietary.
18
Cleanliness Criteria

• The following pictures show examples of good and bad connector surfaces.
• Connectors
. with scratches on the core (dark area) should be rejected. Scratches on
the white area are acceptable

ACCEPTED REJECTED DIRTY


REJECTED BURNED

Copyright © Ciena Corporation 2017. All rights reserved. Confidential & Proprietary.
19
Restoring the Fiber

Copyright © Ciena Corporation 2017. All rights reserved. Confidential & Proprietary.
20
Restoring the Fiber…. Cont’d.

Copyright © Ciena Corporation 2017. All rights reserved. Confidential & Proprietary.
21
Verification of the first 25 km

Copyright © Ciena Corporation 2017. All rights reserved. Confidential & Proprietary.
22
Wavelength grid

OSC
1574n
m

C-band
1530n 1565nm
m

SRP
1276nm 1426n 1454n
m m
Main Seed Main
pump Pump pump

Copyright © Ciena Corporation 2017. All rights reserved. Confidential & Proprietary.
23

You might also like