You are on page 1of 4

FRAME 6114F / 6124F WINDING 6

MODELS LL6114F / LL6124F / LL6134F REF: F6104FW6-3 JULY 2010

WINDING DETAILS MECHANICAL DETAILS


Code 6 Insulation class H Standard protection IP23
Phase 3 Leads 12 Overspeed rpm 2250
Pole number 4 Pitch 2/3 Air flow 50Hz/60Hz m3/s 0.9 / 1.1

EXCITATION DETAILS WAVEFORM


Excitation system SHUNT AREP/PMG Line voltage on no load or balanced linear rated load
AVR model R450M R450M Total harmonic content THC <4%
Sustained short-circuit current - 300%:10s Telephone influence factor TIF (NEMA) <50
Steady state voltage regulation ±0.5% ±0.5% Telephone harmonic factor THF (IEC) <2%

LINE VOLTAGE No overvoltage tolerance for 440V 50Hz excitation level


Frequency / speed 50Hz / 1500rpm 60Hz / 1800rpm
Series star V 380 400 415 440 380 400 416 440 460 480
Series delta V 220 230 240 220 230 240
Parallel star V 200 208 220 200 208 220 230 240
1 2 3 4 6 7 8 9 10 11
RATING Power factor 0.8, Altitude <=1000m
Class H rise BR 125/40 kVA 510 510 510 460 580 610 615 630 640 640
kW 408 408 408 368 464 488 492 504 512 512
Class H rise PR 150/40 kVA 541 541 541 488 615 647 652 668 678 678
kW 432 432 432 390 492 517 522 534 543 543
Class H rise PR 163/27 kVA 561 561 561 506 638 671 677 693 704 704
kW 449 449 449 405 510 537 541 554 563 563
Class F rise BR 105/40 kVA 464 464 464 419 528 555 560 573 582 582
kW 371 371 371 335 422 444 448 459 466 466

EFFICIENCIES Power factor 0.8


110% Class H BR % 94.0 94.2 94.3 94.3 93.2 93.5 93.7 94.0 94.2 94.3
100% Class H BR % 94.3 94.5 94.5 94.4 93.5 93.8 94.0 94.2 94.4 94.5
75% Class H BR % 94.8 94.8 94.8 94.4 94.1 94.3 94.5 94.6 94.7 94.7
50% Class H BR % 94.9 94.8 94.6 93.8 94.2 94.4 94.4 94.5 94.5 94.4
25% Class H BR % 93.2 92.9 92.4 90.7 92.4 92.5 92.4 92.3 92.2 91.8

CHARACTERISTIC PARAMETERS Reactance base class H BR rating


Kc Short-circuit ratio 0.34 0.40 0.47 0.69 0.22 0.24 0.26 0.30 0.33 0.39
Xd D-Axis synchronous reactance (unsaturated) pu 3.47 3.13 2.91 2.33 4.73 4.49 4.19 3.83 3.56 3.27
X'd D-Axis transient reactance (saturated) pu 0.18 0.16 0.15 0.12 0.24 0.23 0.22 0.20 0.18 0.17
X''d D-Axis sub-transient reactance (saturated) pu 0.125 0.113 0.105 0.084 0.171 0.162 0.151 0.138 0.128 0.118
Xq Q-Axis synchronous reactance (unsaturated) pu 2.08 1.88 1.74 1.40 2.84 2.69 2.51 2.30 2.14 1.96
X''q Q-Axis sub-transient reactance (saturated) pu 0.166 0.150 0.139 0.112 0.227 0.215 0.201 0.184 0.171 0.157
X2 Negative-sequence reactance (saturated) pu 0.145 0.131 0.122 0.098 0.198 0.188 0.175 0.160 0.149 0.137
X0 Zero-sequence reactance (independent) pu 0.011 0.010 0.009 0.007 0.015 0.014 0.013 0.012 0.011 0.010
T'd D-Axis transient time constant ms 100 100
T''d D-Axis sub-transient time constant ms 10 10
T'do D-Axis open-circuit time constant ms 1930 1930
Ta Armature time constant ms 15 15
Tr Voltage recovery time ms < 500 < 500

EXCITATION VOLTAGE AND CURRENT

No load excitation voltage V 8.9 10.2 11.3 14.2 6.6 7.0 7.5 8.3 9.1 10.2
No load excitation current A 0.87 1.00 1.11 1.39 0.65 0.69 0.74 0.81 0.89 1.00
Class H BR excitation voltage V 37.0 37.3 38.1 38.1 37.5 38.1 37.6 37.6 37.8 38.1
Class H BR excitation current A 3.63 3.66 3.74 3.74 3.68 3.74 3.69 3.69 3.71 3.74

WINDING RESISTANCE At 20 o C
Stator line-to-line (series star) Ω 0.0091 Exciter field Ω 10.20
Main field Ω 0.98

According to: IEC 60034, UTE NFC51.111, VDE 0530, BS 4999/5000, NEMA MG 1-33
Values quoted are typical. In line with our policy of continuous improvement, we reserve the right to change specification without notice.
FRAME 6114F / 6124F WINDING 6

MODELS LL6114F / LL6124F / LL6134F REF: F6104FW6-3 JULY 2010

LOCKED ROTOR MOTOR STARTING CURVES Power factor 0.6

50 Hz SHUNT

380V

400V
415V

440V
35

30

25
voltage dip %

20

15

10

0
0 500 1000 1500 2000 2500
kVA

50 Hz AREP / PMG
380V

400V

415V

440V

35

30

25
voltage dip %

20

15

10

0
0 500 1000 1500 2000 2500
kVA

According to: IEC 60034, UTE NFC51.111, VDE 0530, BS 4999/5000, NEMA MG 1-33
Values quoted are typical. In line with our policy of continuous improvement, we reserve the right to change specification without notice.
FRAME 6114F / 6124F WINDING 6

MODELS LL6114F / LL6124F / LL6134F REF: F6104FW6-3 JULY 2010

LOCKED ROTOR MOTOR STARTING CURVES Power factor 0.6

60 Hz SHUNT

380V

400V
416V

440V

460V

480V
35

30

25
voltage dip %

20

15

10

0
0 500 1000 1500 2000 2500
kVA

60 Hz AREP / PMG
380V

400V
416V

440V

460V

480V

35

30

25
voltage dip %

20

15

10

0
0 500 1000 1500 2000 2500
kVA

According to: IEC 60034, UTE NFC51.111, VDE 0530, BS 4999/5000, NEMA MG 1-33
Values quoted are typical. In line with our policy of continuous improvement, we reserve the right to change specification without notice.
FRAME 6114F / 6124F WINDING 6

MODELS LL6114F / LL6124F / LL6134F REF: F6104FW6-3 JULY 2010

THREE-PHASE SHORT-CIRCUIT DECREMENT CURVES No-load excitation at rated speed

400V 50Hz, 480V 60Hz Series Star

100000
RMS current (A)

asymmetrical
10000

symmetrical
AREP/PMG

SHUNT
1000
1 10 100 1000 10000
time (ms)

Multiplication Factors

50Hz Voltages 380 400 415 440

Multiplication Factor 0.95 1.00 1.04 1.10

Apply factor up to 2xT'd, remainder of curve unchanged

60Hz Voltages 380 400 416 440 460 480

Multiplication Factor 0.79 0.83 0.87 0.92 0.96 1.00

Apply factor up to 2xT'd, remainder of curve unchanged

Winding Connection Series Star Parallel Star Series Delta

Multiplication Factor 1.00 2.00 1.73

Apply factor to the complete curve

According to: IEC 60034, UTE NFC51.111, VDE 0530, BS 4999/5000, NEMA MG 1-33
Values quoted are typical. In line with our policy of continuous improvement, we reserve the right to change specification without notice.