GE AMX IV Plus Portable

X-Ray System
GE AMX IV Plus Portable X-Ray System
The AMX-4 Plus X-Ray unit is a completely self-
contained battery driven, mobile radiographic
system which operates from a rechargeable
battery pack. Mobility and ease of use make
the AMX-4 Plus ideally suited for all routine
radiographic procedures, within intensive care
units, cardiac care units, emergency and
operating rooms, pediatrics, neonatal units,
orthopedics, and clinics.

Contact Us: (918) 440-2025 Sales@SoonerRadiology.com


www.SoonerRadiology.com
GE AMX 4 Plus Portable X-Ray System Specifications

Specifications
Refurbished GE AMX IV Plus systems include a Features:
DR Panel Retrofit Package: Vertical Column Positioning of Xray Tube
through 270-Degree Column Rotation
• 14×17 Portable GadOx or Cesium DR Panel: • 100 mA Constant
• Detection Area: 14×17 inch (35cm x 43 cm) • kVp 50-125, mAs 0.4-320, 24 kVp Stations
• Dimensions: W: 15 x L: 18.1 x D: .59 in. • 30 mAs Stations
(38x46x1.5cm) • X-Ray Tube MX-75 275k HU
• Weight: 6lbs, 8oz (3.1kg) • Focal Spot .75mm
Features: • Dual Motor Drive (Forward and Reverse)
• Preview Image displays in 2 seconds, • Variable Speed Drive
Processed Image in 6 seconds. AMX-4 Plus original manufacturer
• Automatic Exposure Detection (AED) specifications: Control, Microprocessor, High-
eliminates Interface to Generator. Tension Transformer, High-Voltage Cables,
• Same size as normal film cassette for Rotating Anode X-Ray Tube, Collimator,
simple, fast retrofit. Base and Cabinet, Tube Stand, Motor Drive,
• Dramatically reduced X-ray dose increases Batteries, Battery Charging System,
safety to patient and user. Operational and Diagnostic Software

Warranty: 5 Year Manufacturer’s Warranty on Detector, 1 Year MirAssist Managed support

Contact Us: (918) 440-2025 Sales@SoonerRadiology.com www.SoonerRadiology.com


GE AMX 4 Plus Portable X-Ray System Specifications

Technical control: Generator:


• kVp: 50 to 76 in 2 kVp steps • Frequency: 1,000 Hz
• kvP: 80 to 125 in 5 KVp steps • Voltage: 50 to 125 kVp
• mAs: 50-90 kVP, 4 to 320 mAs • Power: 12.5 kW nominal
• 95-105 kVp, 4 to 250mAs • Cables: Vinyl covered, rated to 75 kVp
• 110-125 kVp, 4 to 200 mAs each or 150 kVp for pair. Federal type
• All in 25% increments, 20% decrements connectors.
• mA: 100 mA nominal Batteries:
• Digital readouts, blue vacuum Type: Sealed lead acid. “Minimal liquid” or film
fluorescent. electrolyte technology classifies batteries as
• Top: 1.9 cm (3/4 in) kVp and mAs dry. Cannot leak if punctured. Pack: Nine 12-
• Message: 0.95 cm (3/8 in) all message volt packs connected in series (108 V nominal).
• Battery Status: 0.95 cm (3/8 in) bar graph Runs both motor drive and X-Ray from same
• Switches are dome-type push buttons pack. Unit is shipped with batteries fully
under mylar cover. On/Off Two position charged.
switch: Off/Remove Key, Off, On
• The drive system and X-Ray work only in
ON position. Charger works in either
position. Hand switch controls the rotor
prep, exposure, and remote field light.
• Audible tone: X-Ray On.

Contact Us: (918) 440-2025 Sales@SoonerRadiology.com www.SoonerRadiology.com


GE AMX 4 Plus Portable X-Ray System Specifications

Battery Charging System: Mechanical Dimensions:


• Automatic battery status sensing with • Overall Width 63.9 cm /25 in (Includes front
programmed overcharging protocol for bumper)
maximizing battery life. • Width at Midpoint 60.2/23.8
• Charger cord provided with retraction into • Overall Height 193/76
base. Hospital grade line plug fits standard • Tube Height in 131.8/51.9 (Transport lock
wall receptacle. over)
• Maximum line draw 5A, 110V: 2.5A, 220V • Overall Length 114.8/45.2 (includes handle)
• Unit designed to be charged in any corridor • Length, Base 103.5/40.8
or room space with normal ventilation. Unit • Length, Full Horizontal 212.9/83.8 Arm
should not be charged in closets, etc., or in Extension
areas using isolated power, e.g., surgery. • Tube Positioning:
• Charger operates in any keyswitch position • Maximum Focal Spot 201.2/79.2 Height
as charger mode has precedence over all (standard)
other modes (transport exposure). The • Maximum Focal Spot 186.2/73.3 Height
system can neither be moved, nor used for (short)
X-ray if it is recharging. Charger status • Minimum Focal Spot 62.4/24.6 Height
displayed on message readout. • Vertical Travel 138.4/54.5
110 and 220V, 50/60 Hz operation built in; • Maximum Horizontal 107.6/42.4 Extension
conversion requires no parts except for wall • Minimum Horizontal 67.0/26.4 Extension
plug. • Horizontal Travel 40.6/16.4

Contact Us: (918) 440-2025 Sales@SoonerRadiology.com www.SoonerRadiology.com


GE AMX 4 Plus Portable X-Ray System Specifications

Performance:
• Maximum Speed: 4.8 kph/ Forward or reverse 3.0
mph
• Speed, arm Out of 2.4 kph/ Transport Position 1.5
mph
• Maximum Incline 5° degrees
• Weight: 499 kg/ 1,100 lbs
Power Requirements
• 110V nominal 5A maximum for recharging.
• 220V nominal 2.5A maximum for recharging.
• Weight: Shipping (w/battery) 590 kg