More than 1,675 SGT-A05 gas turbines have been sold Designed for use in power generation and oil & gas
for industrial use to more than 500 customers in 53 applications, features of the SGT-A05 gas turbine include:
countries, accumulating an impressive 120 million
• Lightweight modular construction
operating hours since its introduction in 1963.
• Ease of field repair
Today, these engines are delivered to our customers
• Virtually unlimited cycle capability
through a network of distributors who incorporate the
engine into complete generator sets, both stationary and • black start capability
mobile.
• hot start capability
All Siemens distributors are carefully chosen for their • full power available within 60 seconds
engineering and manufacturing capabilities and
• load following
commitment to adhere to Siemens standards for quality
and delivery. • Wide range of fuels in any environmental condition
• High electrical efficiency
Industrialized Aeroderivative Gas Turbine
2
SGT-A05 Aeroderivative Gas Turbine
The SGT-A05 gas turbine variants produce electrical power More than 75 DLE systems have entered service
output between 4 and 6 MW for applications such as base since its introduction in 1994. This system is also
load, co-generation, combined heat and power, mobile available for upgrade during routine overhaul of
power and emergency power. the SGT-A05.
SGT-A05 variants are fulfilling the requirements of a wide SGT-A05 gas turbine variants produce low
spectrum of applications in terms of efficiency, reliability, emission levels that meet and exceed customers
flexibility and environmental compatibility. requirements as well as emission standards around
the world.
SGT-A05 gas turbine variants offer low life-cycle costs and
an excellent return on investment.
Industrial
Offshore fixed
Application power generation
Base load
Grid support
Combined cycle
Chemical / Rubber & Plastics
Power producers
Buildings & Infrastructure
Manufacturing industries /
Industrial parks Utility Municipality Independent
power producers
3
SGT-A05 Aeroderivative Gas Turbine
Our current offering includes variants of the proven KB5 and KB7 engines:
SGT-A05 KB5S, SGT-A05 KB7S and SGT-A05 variants based on trusted New High Efficiency (HE)
KB7HE technology Compressor Hardware Upgrades
Provide Opportunity to Increase
• Added value to our customers – • Includes latest DLE fuel system Power and Fuel Economy:
Leveraging proven technology and improvements
reputation • 50% turndown capability • Vanes – abradable inner bands
• Improved electrical efficiency • Increased durability through liner • Case – blade track radius for
reduces fuel usage improvements reduced tip clearance
• Increased power output increases • Improved interstage sealing
revenue from the sale of • Includes new generation DLE
electricity or reduce cost of buying liners
additional electricity off of the
grid
• Increased exhaust temperature
and flow increases usable exhaust
for steam production or direct
heat processes
Natural gas, liquid fuel, dual fuel; other fuels on request; automatic
Fuel
changeover from primary to secondary fuel at any load
Exhaust Temperature 560 °C (1,040 °F) 494 °C (921 °F) 522 °C (972 °F)
4
SGT-A05 Aeroderivative Gas Turbine
5
SGT-A05 Aeroderivative Gas Turbine
32.3%
customers with a global network of support.
electrical efficiency
Engine Power and Heat Rate vs. Amb. Temp Exhaust Flow and Temp vs. Amb. Temp
7000 25 550
(9387) 12000 (1022)
(55.1)
540
6500 Engine Power 23 (1004)
(8717)
(50.7)
Exhuast Flow, kg/sec (lb/sec)
6000 (986)
Exh Temp, °C (°F)
Heat Rate kJ/Kw-hr
(8046)
21
(46.3) 520
(968)
5500 11000
(7376)
510
19 (950)
5000 (41.9)
(6705) 500
(932)
10500 Exh Temp
Heat Rate 17
4500 (37.5)
(6035) 490
(914)
15
4000 (33.1) 480
(5364) 10000 (896)
-30 -15 0 15 30 45 -30 -15 0 15 30 45
(-22) (5) (32) (59) (86) (113) (-22) (5) (32) (59) (86) (113)
Amb. Temp, °C (°F) Amb. Temp, °C (°F)
6
SGT-A05 Aeroderivative Gas Turbine
33.2%
electrical efficiency
Engine Power and Heat Rate vs. Amb. Temp Exhaust Flow and Temp vs. Amb. Temp
8000 25 560
12000 (1040)
(10728) (55.1)
7500
(10058) Engine Power
23 Exh Flow 548
7000 (50.7) (1018)
Exhuast Flow, kg/sec (lb/sec)
(9387) 11500
Engine Power, kW (hp)
6500 21 536
(8717) (997)
(46.3)
6000 11000
(8046)
19 524
5500
(7376) (41.9) (975)
5000
(6705) 10500 Exh Temp
17 512
(37.5) (954)
4500
(6035) Heat Rate
15
4000 (33.1) 500
(5364) 10000 (932)
-30 -15 0 15 30 45 -30 -15 0 15 30 45
(-22) (5) (32) (59) (86) (113) (-22) (5) (32) (59) (86) (113)
Amb. Temp, °C (°F) Amb. Temp, °C (°F)
7
SGT-A05 Aeroderivative Gas Turbine
Engine Power and Heat Rate vs. Amb. Temp Exhaust Flow and Temp vs. Amb. Temp
19 610
(41.9) (1130)
13500
5000
(6705) Engine Power
18 600
(39.7) Exh Flow (1112)
Exhuast Flow, kg/sec (lb/sec)
13000
Engine Power, kW (hp)
4500
Exh Temp, °C (°F)
Heat Rate kJ/Kw-hr
(6035) 17 590
(37.5) (1094)
4000 12500
16 580
(5364) (1076)
(35.2)
3500
(4694) 12000 15 Exh Temp 570
Heat Rate (33.1) (1058)
14
3000 (30.9) 560
(4023) 11500 (1040)
-30 -15 0 15 30 45 -30 -15 0 15 30 45
(-22) (5) (32) (59) (86) (113) (-22) (5) (32) (59) (86) (113)
Amb. Temp, °C (°F) Amb. Temp, °C (°F)
8
SGT-A05 Aeroderivative Gas Turbine
Reference Case:
HERA Cogeneration The company operates in the
distribution of gas, water, energy and
Location
Bologna, Italy
Commissioning Date
Autumn 2017
Packager
Centrax Gas Turbines, Ltd.
Application
Cogeneration
Electricity Generated
7.8 MW
Customer Benefits
The new equipment helps to achieve an annual reduction of around 21,000 kg of NOx and 2500 tonnes of CO2
9
SGT-A05 Aeroderivative Gas Turbine
The SGT-A05 is known for its high fuel flexibility, Low Emissions Options
which will accommodate a wide variety of possible
application scenarios and requirements. Three combustion systems are available, based on customer
need:
Fuels include, but are not limited to natural gas,
liquid fuel (or both) and mid to low BTU gas fuels. • Standard combustion system can operate on liquid or
Fuel system options include dual fuel, steam and gas fuel
water injection.
• Wet Low Emissions combustion system utilizes nozzle
Dry Low Emissions (DLE) technology is also available. steam or water
• Dry Low Emissions combustion system achieves better
In addition to the fuel flexibility, SGT-A05 accommodates a
than 25vppm NOx and 50vppm CO (gas fuel only)
wide variety of customer requirements. The compact design
of the engine permits application versatility and ease of
Reliable, Easy Installation and Maintenance
removal and replacement. The SGT-A05 measures less than
2.7 meters (8 feet) long and weighs less than 766 Kg (1,690
Our comprehensive portfolio of services provides low life
pounds).
cycle cost and optimum performance throughout the
turbine’s life cycle: Long Term Programs (LTP), Overhaul
The SGT-A05 is proven to operate in various challenging
service, field service, spare parts, service exchange, remote
conditions and locations around the world including the
diagnostic service and modernization and upgrades.
North Sea, West Africa, Siberia, Brazil, Alaska, South East
Asia and the desert regions of the Middle East.
The modular, compact design of the SGT-A05 facilitates
onsite maintenance, since the modules can be quickly
The SGT-A05 engine has been shock qualified to Mil-S-901C,
replaced. A direct core engine exchange is possible and can
which makes it particularly suitable for areas with frequent
be executed in as little as 12 hours. The proven lightweight
or severe seismic activity.
industrial design allows an easy and economical transport.
Advanced Engineering
• Simple, inexpensive to maintain
Core engine commonality of all SGT-A05 variants • Rugged, reliable performance with up to seven years
baseload duty between full overhaul
• Highest power density in weight class
• Over 98% demonstrated availability/reliability
• Advanced materials including leading edge additive
• Lightweight, aeroderivative, industrial design is easy
manufacturing.
• All SGT-A05 engines are built to meet stringent
industry standards including ISO 9001 and AS9100
• Full power available within 60 seconds from all
conditions, including hot restarts, with no need to go
to an idle condition
• Black Start capability
• Modular gas turbine configuration optimizes spares
requirements, minimizes cost of ownership and
simplifies engine maintenance
10
SGT-A05 Aeroderivative Gas Turbine
Lubricating Oil System • Includes filter assembly, silencer and flow direction
geometry
• Common synthetic lube oil system for both engine and • Site-specific design minimizes disruption of inlet air
package
• Filtration systems are available to handle extreme
• Main “engine” lube and scavenge oil pump is driven off environments – arctic cold, salt water spray, severe
the engine accessory gearbox for normal operation and heat and dust
shutdown
• Single to multiple stages handle offshore, coastal and
• Oil system components are skid-mounted and designed inland sites
to industry standards
• Optional heaters/coolers to meet the climate needs of Gas Turbine Enclosure
the application
• Acoustic enclosures meet a wide range of requirements
Fuel System and environments
• Factory-completed enclosure can house all auxiliary
• On-skid fuel system includes all components needed to equipment on engine skid, with piping and wiring
control fuel during start up and operation completed and tested at the factory
• Operates on natural gas, liquid, dual fuel, and low BTU • Completed enclosures shipped with connections intact
gas with steam and water injection for simplified installation and commissioning
Dry Low Emissions (DLE) system available on: SGT-A05 KB7S • Maintains performance by preventing build-up of
and SGT-A05 KB7HE / SGT-A05 KB5S contaminants in the engine compressor
11
SGT-A05 Aeroderivative Gas Turbine
Engine Lease
12
SGT-A05 Aeroderivative Gas Turbine
e Compressor
Turbine Section
Combustion Section
13
SGT-A05 Aeroderivative Gas Turbine
A Global Network
SGT-A05 packagers and Siemens maintenance,
repair and overhaul centers
Our customers may be located in diverse regions around the world, but they all have one
thing in common. They all require timely and accurate support to purchase, install and
maintain their SGT-A05 gas turbines and equipment. That’s why we continually invest in our
global infrastructure from distributors to repair and overhaul facilities.
SGT-A05 Packagers
Maintenance, Repair
and Overhaul Centers
(MROC)
Aeroderivative
Business Locations &
Service Centers
General SGT-A05 and Aftermarket Hitachi Zosen Corporation (Japan) Standard Aero Ltd.
Inquiries ene-siemensgt@mml.is.hi-tachizosen.co.jp jeff.sansome@standardaero.com
+81 6 6569 0209 +1 204 775 9711
Siemens Energy Inc.
Small Engine Business
Kobelco Hindustan Aeronautical Ltd. (HAL)
201 S. Capitol Ave Suite 910
http://www.kobelco.co.jp/english/ mktg.imgt@hal-india.com
Indianapolis, In 46225 USA
machinery/inquiry/index.html +91 80 2232 6803
Phone: +1 (317) 677-1340
+81-3-5739-6772
Fax: +1 (317) 677-1341
Spare Parts Distributor
Packagers and Heavy Maintenance Packagers
Centers (HMC) Tominaga & Co., Ltd. (Japan)
OnPower, Inc. (North America)
general-affairs@mail.tomco.co.jp
Centrax Limited, Gas Turbine info@onpowerinc.com
+81 3 3639 5360
Division (Europe) +1 513 228 2100
info@centraxgt.com
+44 1626 358 000 Maintenance, Repair and Overhaul
Centers
IHI Jet Service (Japan)
ijs_eigyoubu@ijs.ihi.co.jp RWG Inc.
+81 3 6204 7718 501sales@rwgroup.com
+1 713 538 9700
14
SGT-A05 Aeroderivative Gas Turbine
15
Published by and copyright © 2018:
Siemens AG
Power and Gas
Freyeslebenstrasse 1
91058 Erlangen, Germany
For more information, please contact our Customer
Support Center.
Phone: +49 180 524 70 00
Fax: +49 180 524 24 71
(Charges depending on provider)
E–mail: support.energy@siemens.com
All rights reserved. Trademarks mentioned in this
document are the property of Siemens AG, its affiliates, or
their respective owners. Product Mark 501 is a trademark
of and used under license from Rolls-Royce plc.
Subject to change without prior notice. The information in
this document contains general descriptions of the
technical options available, which may not apply in all
cases. The required technical options should therefore be
specified in the contract.