You are on page 1of 5

CENG321 , Sem 1 2020/2021 , Dr.

Fuad Musleh

Name:
Section:
Student No:

CENG321 HYDRAULICS
PROJECT
Sem. I 2020-2021
Project (sem. I 2020-2021)
Find the water flow in all the pipe branches of the network shown, and the pressure at all the
joints of pipes . (e = 0.20 mm).

Diameter Length Suggested final Q Power


Pipe (mm)
Area
(m)
e/D f K Q (m3/s) (m3/s)
hf (m)
(watt)
1 1580 360
2 1670 300
3 1670 490
4 1670 180
2+4 1670 480
5 1450 410
6 1450 200
7 1450 280
8 1450 350
9 1450 695
10 1450 660
11 1450 600
12 1450 290
13 1450 275
14 1450 250
15 1450 690
16 1450 650
Pressure Drop through different paths = (………………..), (………………..), (………………..) Pascal
Project (sem. I 2020-2021)
Iteration 1 Iteration 2 Iteration 3
3 2 3
l Pipe Q (m /s) K KQ KQ Qnew Q (m /s) K KQ KQ2 Qnew 3
Q (m /s) K KQ KQ2 Qnew
o
1
o
p
2 +4
3
1 5
correction ∆Q= ∆Q= ∆Q=
3 2 3 2
Pipe Q (m /s) K KQ KQ Qnew Q (m /s) K KQ KQ Qnew Q (m3/s) K KQ KQ2 Qnew
l 5
o
6
o
p
8
7
2 10
∆Q= ∆Q= ∆Q=
l
o
Pipe Q (m3/s) K KQ 2
KQ Qnew 3
Q (m /s) K KQ KQ 2
Qnew Q (m3/s) K KQ KQ2 Qnew
o 8
p
9
3 11
correction ∆ Q = ∆Q= ∆Q=
l
o
Pipe Q (m3/s) K KQ 2
KQ Qnew 3
Q (m /s) K KQ KQ 2
Qnew Q (m3/s) K KQ KQ2 Qnew
o 10
p
12
4 13
15
correction ∆ Q = ∆Q= ∆Q=
Pipe Q (m3/s) K KQ 2
KQ Qnew 3
Q (m /s) K KQ KQ 2
Qnew Q (m3/s) K KQ KQ2 Qnew
l 11
o 13
o
p
14
5 16
correction ∆ Q = ∆Q= ∆Q=

Check Nodes Check Nodes Check Nodes


1,(2+4) 1,(2+4) 1,(2+4)
1,3 1,3 1,3
3,5,6 3,5,6 3,5,6
4, 5,7 4, 5,7 4, 5,7
6,8,9 6,8,9 6,8,9
7,10,12 7,10,12 7,10,12
8,10,11,13 8,10,11,13 8,10,11,13
9,11.14 9,11.14 9,11.14
12,15 12,15 12,15
13, 15,16 13, 15,16 13, 15,16
14,16 14,16 14,16
Project (sem. I 2020-2021)
Iteration 4 Iteration 5 Iteration 6
3 2 3
l Pipe Q (m /s) K KQ KQ Qnew Q (m /s) K KQ KQ2 Qnew 3
Q (m /s) K KQ KQ2 Qnew
o
1
o
p
2 +4
3
1 5
correction ∆Q= ∆Q= ∆Q=
3 2 3 2
Pipe Q (m /s) K KQ KQ Qnew Q (m /s) K KQ KQ Qnew Q (m3/s) K KQ KQ2 Qnew
l 5
o
6
o
p
8
7
2 10
∆Q= ∆Q= ∆Q=
l
o
Pipe Q (m3/s) K KQ KQ2 Qnew Q (m3/s) K KQ KQ2 Qnew Q (m3/s) K KQ KQ2 Qnew
o 8
p
9
3 11
correction ∆ Q = ∆Q= ∆Q=
l
o
Pipe Q (m3/s) K KQ KQ2 Qnew Q (m3/s) K KQ KQ2 Qnew Q (m3/s) K KQ KQ2 Qnew
o 10
p
12
4 13
15
correction ∆ Q = ∆Q= ∆Q=
Pipe Q (m3/s) K KQ KQ2
Qnew 3
Q (m /s) K KQ KQ 2
Qnew Q (m3/s) K KQ KQ2 Qnew
l 11
o 13
o
p
14
5 16
correction ∆ Q = ∆Q= ∆Q=

Check Nodes Check Nodes Check Nodes


1,(2+4) 1,(2+4) 1,(2+4)
1,3 1,3 1,3
3,5,6 3,5,6 3,5,6
4, 5,7 4, 5,7 4, 5,7
6,8,9 6,8,9 6,8,9
7,10,12 7,10,12 7,10,12
8,10,11,13 8,10,11,13 8,10,11,13
9,11.14 9,11.14 9,11.14
12,15 12,15 12,15
13, 15,16 13, 15,16 13, 15,16
14,16 14,16 14,16
Project (sem. I 2020-2021)