Professional Documents
Culture Documents
T POWER (P) O-
Y CONTROLN
CONDUIT
P (C); GROUND
NUMBER
SERVICE D
CABLE /
FROM TO E (G) -
INSTRUMEN U
NO.T &
(I)
SIZECT
ARAMCO O
RS
PC-0201 Ju'aymah NGL EXISTING MCC R83-P- R83-DSW(D)-017 P 1-3/C x 50 mm²
861M
480V MAIN CONTROL DISCONNECT SWITCH G
CENTER
PC-0202 Ju'aymah NGL R83-DSW(D)-017 R83-XFR(T)-003 P 1-3/C x 50 mm²
PC-0215 SPARE
PC-0216 SPARE
PC-0217 SPARE
PC-0218 SPARE
PC-0219 SPARE
PC-0220 SPARE
PC-0341 Khursaniyah Plant PANEL-03 2 UVIS SCANNER (LOOP) P/G 1-3/C-10 mm2
PC-0343 SPARE
PC-0344 SPARE
PC-0345 SPARE
PC-0346 SPARE
PC-0347 SPARE
PC-0348 SPARE
PC-0349 SPARE
PC-0350 SPARE
PC-0351 SPARE
PC-0352 SPARE
PC-0353 SPARE
PC-0354 SPARE
PC-0355 SPARE
PC-0356 SPARE
PC-0357 SPARE
PC-0358 SPARE
PC-0359 SPARE
PC-0360 SPARE
PC-0361 Qatif Bulk Plant X16-SG302-MCC-001 X17-DSW(D)-001 P 1-3/C x 95 mm²
PC-0372 SPARE
PC-0373 SPARE
PC-0374 SPARE
PC-0375 SPARE
PC-0376 SPARE
PC-0377 SPARE
PC-0378 SPARE
PC-0379 SPARE
PC-0380 SPARE
PC-0401 QATIF LPG X17-001-PP-011 2 UVIS SCANNER (LOOP) P/G 1-3/C-4 mm2
PC-0403 SPARE
PC-0404 SPARE
PC-0405 SPARE
PC-0406 SPARE
PC-0407 SPARE
PC-0408 SPARE
PC-0409 SPARE
PC-0410 SPARE
PC-0411 SPARE
PC-0412 SPARE
PC-0413 SPARE
PC-0414 SPARE
PC-0415 SPARE
PC-0416 SPARE
PC-0417 SPARE
PC-0418 SPARE
PC-0419 SPARE
PC-0420 SPARE
PC-0441 RT Refinery (Gate #25) LPG 3 UVIS SCANNER P/G 1-3/C-25 mm2
EXISTING LIGHTING
PANEL
PC-0442 RT Refinery (Gate #25) LPG 2 PTZ CAMERA P/G 1-3/C-4 mm2
EXISTING LIGHTING
PANEL
PC-0443 SPARE
PC-0444 SPARE
PC-0445 SPARE
PC-0446 SPARE
PC-0447 SPARE
PC-0448 SPARE
PC-0449 SPARE
PC-0450 SPARE
PC-0451 SPARE
PC-0452 SPARE
PC-0453 SPARE
PC-0454 SPARE
PC-0455 SPARE
PC-0456 SPARE
PC-0457 SPARE
PC-0458 SPARE
PC-0459 SPARE
PC-0460 SPARE
PC-0461 RT Terminal North LP-3 UVIS SCANNER P/G 1-3/C-6 mm2
EXISTING LIGHTING
PANEL
PC-0462 RT Terminal North LP-3 PTZ CAMERA P/G 1-3/C-4 mm2
EXISTING LIGHTING
PANEL
PC-0463 SPARE
PC-0464 SPARE
PC-0465 SPARE
PC-0466 SPARE
PC-0467 SPARE
PC-0468 SPARE
PC-0469 SPARE
PC-0470 SPARE
PC-0471 SPARE
PC-0472 SPARE
PC-0473 SPARE
PC-0474 SPARE
PC-0475 SPARE
PC-0476 SPARE
PC-0477 SPARE
PC-0478 SPARE
PC-0479 SPARE
PC-0480 SPARE
PC-0481 RT Terminal South LP-3 2 UVIS SCANNER (LOOP) P/G 1-3/C-6 mm2
EXISTING LIGHTING
PANEL
PC-0482 RT Terminal South LP-3 PTZ CAMERA P/G 1-3/C-4 mm2
EXISTING LIGHTING
PANEL
PC-0483 RT Terminal South LP-3 PTZ CAMERA P/G 1-3/C-4 mm2
EXISTING LIGHTING
PANEL
PC-0484 SPARE
PC-0485 SPARE
PC-0486 SPARE
PC-0487 SPARE
PC-0488 SPARE
PC-0489 SPARE
PC-0490 SPARE
PC-0491 SPARE
PC-0492 SPARE
PC-0493 SPARE
PC-0494 SPARE
PC-0495 SPARE
PC-0496 SPARE
PC-0497 SPARE
PC-0498 SPARE
PC-0499 SPARE
PC-0500 SPARE
PC-0501 RT West Pier - X-Ray PB-1S1A 056-DSW(D)-008 P 1-4/C-50 mm2
Building
DISCONNECT SWITCH G
PC-0508 SPARE
PC-0509 SPARE
PC-0510 SPARE
PC-0511 SPARE
PC-0512 SPARE
PC-0513 SPARE
PC-0514 SPARE
PC-0515 SPARE
PC-0516 SPARE
PC-0517 SPARE
PC-0518 SPARE
PC-0519 SPARE
PC-0520 SPARE
PC-0761 Safaniyah Communications 480V SWITCHBOARD X18-DSW(D)-006 P 1-4/C-35 mm2
DCO
PC-0768 SPARE
PC-0769 SPARE
PC-0770 SPARE
PC-0771 SPARE
PC-0772 SPARE
PC-0773 SPARE
PC-0774 SPARE
PC-0775 SPARE
PC-0776 SPARE
PC-0777 SPARE
PC-0778 SPARE
PC-0779 SPARE
PC-0780 SPARE
PC-0821 Tanajib Plant LP-1 2 UVIS SCANNER (LOOP) P/G 1-3/C-16 mm2
EXISTING LIGHTING
PANEL
PC-0822 Tanajib Plant LP-1 2 PTZ CAMERA P/G 1-3/C-4 mm2
EXISTING LIGHTING
PANEL
PC-0823 SPARE
PC-0824 SPARE
PC-0825 SPARE
PC-0826 SPARE
PC-0827 SPARE
PC-0828 SPARE
PC-0829 SPARE
PC-0830 SPARE
PC-0831 SPARE
PC-0832 SPARE
PC-0833 SPARE
PC-0834 SPARE
PC-0835 SPARE
PC-0836 SPARE
PC-0837 SPARE
PC-0838 SPARE
PC-0839 SPARE
PC-0840 SPARE
PC-0861 Berri Gas Plant T-201, 750KVA LOOP FEED M90-XFR(T)-001 P/G 1-3/C-120 mm2
TRANSFORMER
NEAR PIPELINE BUILDING 480V-400/230V TRANSFORMER
PC-0862 Berri Gas Plant M90-XFR(T)-001 M90-ECB-001 P 1-4/C-95 mm2
DISCONNECT SWITCH G
PC-0873 Berri Gas Plant M90-EDG-001 M90-ATS-001 P 1-4/C-95 mm2
EXISTING LIGHTING G
PANEL
PC-0876 Berri Gas Plant LPG 2 PTZ CAMERA P 1-3/C-10 mm2
EXISTING LIGHTING G
PANEL
PC-0877 SPARE
PC-0878 SPARE
PC-0879 SPARE
PC-0880 SPARE
PC-0921 MANIFA PLANT Q43-002-PP-0113 2 UVIS SCANNER (LOOP) P/G 1-3/C-6 mm2
PC-0923 SPARE
PC-0924 SPARE
PC-0925 SPARE
PC-0926 SPARE
PC-0927 SPARE
PC-0928 SPARE
PC-0929 SPARE
PC-0930 SPARE
PC-0931 SPARE
PC-0932 SPARE
PC-0933 SPARE
PC-0934 SPARE
PC-0935 SPARE
PC-0936 SPARE
PC-0937 SPARE
PC-0938 SPARE
PC-0939 SPARE
PC-0940 SPARE
PC-0941 Wasit Gas Plant Q75-240-PP-079 2 UVIS SCANNER (LOOP) P/G 1-3/C-4 mm2
PC-0942 Wasit Gas Plant Q75-240-PP-079 2 PTZ CAMERA P/G 1-3/C-4 mm2
PC-0943 SPARE
PC-0944 SPARE
PC-0945 SPARE
PC-0946 SPARE
PC-0947 SPARE
PC-0948 SPARE
PC-0949 SPARE
PC-0950 SPARE
PC-0951 SPARE
PC-0952 SPARE
PC-0953 SPARE
PC-0954 SPARE
PC-0955 SPARE
PC-0956 SPARE
PC-0957 SPARE
PC-0958 SPARE
PC-0959 SPARE
PC-0960 SPARE
TOTAL QTY
REMARKS
CRCC ARAMCO Aramco CU/XLPE/PVC
CRCC ARAMCO
CU/XLPE/P CU/XLPE/PVC GRD
CU/XLPE/PVC GROUNDIN SIZE
VC GRD
15 1/C-35 mm² 15 30 30
15 1/C-16 mm² 15 5 5
10 1/C-16 mm² 10 5 5
15 1/C-10 mm² 15 10 10
15 1/C-25 mm² 15 10 10
37 1/C-16 mm² 37 25 25
8 1/C-16 mm² 8 5 5
98 1/C-16 mm² 98 85 85
30 1/C-16 mm² 30 20 20
8 1/C-16 mm² 8 5 5
20 1/C-16 mm² 20 20 20
50 1-3/C-10 mm2 50 50 50 DIRECT BURIED
(ARMORED)
15 1/C-35 mm2 15 15 15
12 1/C-16 mm2 12 10 10
12 1/C-6 mm2 12 10 10
20 1/C-16 mm2 20 30 30
15 1/C-6 mm2 15 15 15
30 1/C-16 mm2 30 25 25
7 1/C-16 mm2 7 5 5
25 1/C-16 mm2 25 20 20
7 1/C-16 mm2 7 5 5
35 30 DIRECT BURIED
(ARMORED)
35 35 DIRECT BURIED
(ARMORED)
80 70 DIRECT BURIED
(ARMORED)
35 45 DIRECT BURIED
(ARMORED)
74 70 DIRECT BURIED
(ARMORED)
65 60 DIRECT BURIED
(ARMORED)
40 37 DIRECT BURIED
(ARMORED)
35 30 DIRECT BURIED
(ARMORED)
30 30 DIRECT BURIED
(ARMORED)
122 122 DIRECT BURIED
122 1/C-25 mm2 122 (ARMORED)
8 5
9 1/C-25 mm2 8
5 5
7 1/C-16 mm2 7
10 10
10 1/C- 6 mm2 10
2 2
7 1/C- 6 mm2 7
10 10
12 1/C- 4 mm2 12
5 5
10 1/C- 4 mm2 10
100 100 DIRECT BURIED
103 1/C-16 mm2 103 (ARMORED)
10 10 DIRECT BURIED
10 1/C-16 mm2 10 (ARMORED)
10 10
10 1/C-16 mm2 10
10 10 DIRECT BURIED
10 1/C-10 mm2 10 (ARMORED)
2 2 DIRECT BURIED
5 1/C-10 mm2 5 (ARMORED)
10 10
10 1/C-10 mm2 10
2 2
5 1/C-4 mm2 5
65 60 DIRECT BURIED
(ARMORED)
50 45 DIRECT BURIED
(ARMORED)
500 1C-120 mm2 500 500 500 DIRECT BURIED
(ARMORED)
10 1/C-50 mm2 10 5 5
10 1/C-16 mm2 10 10 10
10 1/C-16 mm2 10 5 5
12 1/C-16 mm2 12 10 10
15 1/C-6 mm2 15 10 10
7 1/C-6 mm2 7 5 5
35 1/C-6 mm2 35 10 10
7 1/C-6 mm2 7 5 5
17 1/C-6 mm2 17 10 10
7 1/C-6 mm2 7 5 5
50 50 50 50 DIRECT BURIED
(ARMORED)
45 34 DIRECT BURIED
(ARMORED)
30 25 DIRECT BURIED
(ARMORED)
44 40 DIRECT BURIED
(ARMORED)
35 30 DIRECT BURIED
(ARMORED)
LOAD GLAND TYPE
HP "FROM"
OR END
CONDUIT
NUMBER
SERVICE
CABLE /
KVA VOLTS
PC-0343 SPARE
PC-0344 SPARE
PC-0345 SPARE
PC-0346 SPARE
PC-0347 SPARE
PC-0348 SPARE
PC-0349 SPARE
PC-0350 SPARE
PC-0351 SPARE
PC-0352 SPARE
PC-0353 SPARE
PC-0354 SPARE
PC-0355 SPARE
PC-0356 SPARE
PC-0357 SPARE
PC-0358 SPARE
PC-0359 SPARE
PC-0360 SPARE
LEGEND : NOTE
C - Conduit (Per SAES-P-104)
CC - Electrical Control (Per SAES-P-104) PC - Power Cable (Per SAES-P-104)
IC - Instrument Cable (Per SAES-J-902)
REFERENCE DRAWING
DWG. CONTROL FOR J.O.10-00965-0001
PANELBOARD SCHEDULE
GLAND TYPE RUN CONDUITS
" TO " TY FIBER (F) ; STEEL (S) STL P
PE (SP)
END
PVC (P)
FROM TO
SIZE
REFERENCE DRAWING
965-0001 PD-00ADCL
PA-10P102 REV. NO. DATE REVISION DESCRIPTION
B 12/05/2019 ISSUED FOR 100% PROJECT PROPOSAL
JOB ORDER / EWO NO. THIS REVISION IS NOT TO BE USED FOR CONSTRUCTION
10-00965-0001 AND DATED
CONDUITS CONDUCTORS TOTAL
FIBER (F) ; STEEL (S) STL PVC COATED T POWER (P) - CONTROL (C); GROUND (G) QTY
(SP) Y - INSTRUMENT (I)
PVC (P) P REMARKS
E
LENGTH
Ft / m
NO. & SIZE INSULATION FEET
BENDS
TYPE VOLTS METER
P/G 1-3/C-10 mm2 CU/XLPE 600V 50 DIRECT BURIED (ARMORED)
/PVC
KHURSANIYAH
SAUDI ARABIA
OPOSAL
PLANT NO. INDEX DRAWING NUMBER SHEET NO.
TO BE USED FOR CONSTRUCTION UNTIL CERTIFIED
K44 P PD-10P103 001
REMARKS
CT BURIED (ARMORED)
CT BURIED (ARMORED)
ANY
DWG. TYPE
CCS
REV. NO.
B
LOAD GLAND TYPE
HP "FROM"
OR END
CONDUIT
NUMBER
SERVICE
CABLE /
KVA VOLTS
PC-0372 SPARE
PC-0373 SPARE
PC-0374 SPARE
PC-0375 SPARE
PC-0376 SPARE
PC-0377 SPARE
PC-0378 SPARE
PC-0379 SPARE
PC-0380 SPARE
LEGEND : NOTE
C - Conduit (Per SAES-P-104)
CC - Electrical Control (Per SAES-P-104) PC - Power Cable (Per SAES-P-104)
IC - Instrument Cable (Per SAES-J-902)
REFERENCE DRAWING
DWG. CONTROL FOR J.O.10-00965-0001
ELECTRICAL ONE LINE DIAGRAM
CABLE ROUTING LAYOUT
GLAND TYPE RUN CONDUITS
" TO " TY FIBER (F) ; STEEL (S) STL P
PE (SP)
END
PVC (P)
FROM TO
SIZE
X16-SG302-MCC-001 X17-DSW(D)-001
REFERENCE DRAWING
965-0001 PD-00ADCL
AM PA-11P311 REV. NO. DATE REVISION DESCRIPTION
B 12/05/2019 ISSUED FOR 100% PROJECT PROPOSAL
PA-11O262
JOB ORDER / EWO NO. THIS REVISION IS NOT TO BE USED FOR CONSTRUCTION
10-00965-0001 AND DATED
CONDUITS CONDUCTORS TOTAL
FIBER (F) ; STEEL (S) STL PVC COATED T POWER (P) - CONTROL (C); GROUND (G) QTY
(SP) Y - INSTRUMENT (I)
PVC (P) P REMARKS
E
LENGTH
Ft / m
NO. & SIZE INSULATION FEET
BENDS
TYPE VOLTS METER
P 1-3/C x 95 mm² CU/XLPE 600V 200 DIRECT BURIED (ARMORED)
/PVC
G 1/C-50 mm2 CU/PVC 600V 200
P 1-3/C x 50 mm² CU/XLPE 600V 5 DIRECT BURIED (ARMORED)
/PVC
G 1/C-25 mm2 CU/PVC 600V 5
P 1-3/C x 70 mm² CU/XLPE 600V 15
/PVC
G 1/C-35 mm2 CU/PVC 600V 15
P 1-3/C x 35 mm² CU/XLPE 600V 10
/PVC
G 1/C-16 mm2 CU/PVC 600V 10
P 1-3/C-10 mm2 CU/XLPE 600V 10
/PVC
G 1/C-6 mm2 CU/PVC 600V 10
P 1-4/C-35 mm2 CU/XLPE 600V 30
/PVC
G 1/C-16 mm2 CU/PVC 600V 30
P 1-3/C-10 mm2 CU/XLPE 600V 15
/PVC
G 1/C-6 mm2 CU/PVC 600V 15
P 1-4/C-35 mm2 CU/XLPE 600V 25
/PVC
G 1/C-16 mm2 CU/PVC 600V 25
P 1-4/C-35 mm2 CU/XLPE 600V 5
/PVC
G 1/C-16 mm2 CU/PVC 600V 5
P 1-4/C-35 mm2 CU/XLPE 600V 20
/PVC
G 1/C-16 mm2 CU/PVC 600V 20
P 1-4/C-35 mm2 CU/XLPE 600V 5
/PVC
G 1/C-16 mm2 CU/PVC 600V 5
TION SAUDI ARABIAN OIL COMPANY
RTIFICATION REQUIREMENTS, PER SAEP-334,
CERTIFICATE NO: DWG. TYPE
01
CCS
CABLE & CONDUIT SCHEDULE
QATIF
SAUDI ARABIA
OPOSAL
PLANT NO. INDEX DRAWING NUMBER SHEET NO.
TO BE USED FOR CONSTRUCTION UNTIL CERTIFIED
X17 O PD-11P316 001
REMARKS
CT BURIED (ARMORED)
CT BURIED (ARMORED)
ANY
DWG. TYPE
CCS
REV. NO.
B
LOAD GLAND TYPE
HP "FROM"
OR END
CONDUIT
NUMBER
SERVICE
CABLE /
KVA VOLTS
PC-0403 SPARE
PC-0404 SPARE
PC-0405 SPARE
PC-0406 SPARE
PC-0407 SPARE
PC-0408 SPARE
PC-0409 SPARE
PC-0410 SPARE
PC-0411 SPARE
PC-0412 SPARE
PC-0413 SPARE
PC-0414 SPARE
PC-0415 SPARE
PC-0416 SPARE
PC-0417 SPARE
PC-0418 SPARE
PC-0419 SPARE
PC-0420 SPARE
LEGEND : NOTE
C - Conduit (Per SAES-P-104)
CC - Electrical Control (Per SAES-P-104) PC - Power Cable (Per SAES-P-104)
IC - Instrument Cable (Per SAES-J-902)
REFERENCE DRAWING
DWG. CONTROL FOR J.O.10-00965-0001
PANELBOARD SCHEDULE
GLAND TYPE RUN CONDUITS
" TO " TY FIBER (F) ; STEEL (S) STL P
PE (SP)
END
PVC (P)
FROM TO
SIZE
REFERENCE DRAWING
965-0001 PD-00ADCL
PA-12P103 REV. NO. DATE REVISION DESCRIPTION
B 12/05/2019 ISSUED FOR 100% PROJECT PROPOSAL
JOB ORDER / EWO NO. THIS REVISION IS NOT TO BE USED FOR CONSTRUCTION
10-00965-0001 AND DATED
CONDUITS CONDUCTORS TOTAL
FIBER (F) ; STEEL (S) STL PVC COATED T POWER (P) - CONTROL (C); GROUND (G) QTY
(SP) Y - INSTRUMENT (I)
PVC (P) P REMARKS
E
LENGTH
Ft / m
NO. & SIZE INSULATION FEET
BENDS
TYPE VOLTS METER
P/G 1-3/C-4 mm2 CU/XLPE 600V 30 DIRECT BURIED (ARMORED)
/PVC
QATIF
SAUDI ARABIA
OPOSAL
PLANT NO. INDEX DRAWING NUMBER SHEET NO.
TO BE USED FOR CONSTRUCTION UNTIL CERTIFIED
X17 P PD-12P104 001
REMARKS
CT BURIED (ARMORED)
CT BURIED (ARMORED)
ANY
DWG. TYPE
CCS
REV. NO.
B
LOAD GLAND TYPE
HP "FROM"
OR END
CONDUIT
NUMBER
SERVICE
CABLE /
KVA VOLTS
PC-0443 SPARE
PC-0444 SPARE
PC-0445 SPARE
PC-0446 SPARE
PC-0447 SPARE
PC-0448 SPARE
PC-0449 SPARE
PC-0450 SPARE
PC-0451 SPARE
PC-0452 SPARE
PC-0453 SPARE
PC-0454 SPARE
PC-0455 SPARE
PC-0456 SPARE
PC-0457 SPARE
PC-0458 SPARE
PC-0459 SPARE
PC-0460 SPARE
LEGEND : NOTE
C - Conduit (Per SAES-P-104)
CC - Electrical Control (Per SAES-P-104) PC - Power Cable (Per SAES-P-104)
IC - Instrument Cable (Per SAES-J-902)
REFERENCE DRAWING
DWG. CONTROL FOR J.O.10-00965-0001
PANELBOARD SCHEDULE
GLAND TYPE RUN CONDUITS
" TO " TY FIBER (F) ; STEEL (S) STL P
PE (SP)
END
PVC (P)
FROM TO
SIZE
REFERENCE DRAWING
965-0001 PD-00ADCL
PA-13P103 REV. NO. DATE REVISION DESCRIPTION
B 12/05/2019 ISSUED FOR 100% PROJECT PROPOSAL
JOB ORDER / EWO NO. THIS REVISION IS NOT TO BE USED FOR CONSTRUCTION
10-00965-0001 AND DATED
CONDUITS CONDUCTORS TOTAL
FIBER (F) ; STEEL (S) STL PVC COATED T POWER (P) - CONTROL (C); GROUND (G) QTY
(SP) Y - INSTRUMENT (I)
PVC (P) P REMARKS
E
LENGTH
Ft / m
NO. & SIZE INSULATION FEET
BENDS
TYPE VOLTS METER
P/G 1-3/C-25 mm2 CU/XLPE 600V 70 DIRECT BURIED (ARMORED)
/PVC
RAS TANURA
SAUDI ARABIA
OPOSAL
PLANT NO. INDEX DRAWING NUMBER SHEET NO.
TO BE USED FOR CONSTRUCTION UNTIL CERTIFIED
M90 P PD-13P104 001
REMARKS
CT BURIED (ARMORED)
CT BURIED (ARMORED)
ANY
DWG. TYPE
CCS
REV. NO.
B
LOAD GLAND TYPE
HP "FROM"
OR END
CONDUIT
NUMBER
SERVICE
CABLE /
KVA VOLTS
PC-0463 SPARE
PC-0464 SPARE
PC-0465 SPARE
PC-0466 SPARE
PC-0467 SPARE
PC-0468 SPARE
PC-0469 SPARE
PC-0470 SPARE
PC-0471 SPARE
PC-0472 SPARE
PC-0473 SPARE
PC-0474 SPARE
PC-0475 SPARE
PC-0476 SPARE
PC-0477 SPARE
PC-0478 SPARE
PC-0479 SPARE
PC-0480 SPARE
LEGEND : NOTE
C - Conduit (Per SAES-P-104)
CC - Electrical Control (Per SAES-P-104) PC - Power Cable (Per SAES-P-104)
IC - Instrument Cable (Per SAES-J-902)
REFERENCE DRAWING
DWG. CONTROL FOR J.O.10-00965-0001
PANELBOARD SCHEDULE
GLAND TYPE RUN CONDUITS
" TO " TY FIBER (F) ; STEEL (S) STL P
PE (SP)
END
PVC (P)
FROM TO
SIZE
REFERENCE DRAWING
965-0001 PD-00ADCL
PA-14P103 REV. NO. DATE REVISION DESCRIPTION
B 12/05/2019 ISSUED FOR 100% PROJECT PROPOSAL
JOB ORDER / EWO NO. THIS REVISION IS NOT TO BE USED FOR CONSTRUCTION
10-00965-0001 AND DATED
CONDUITS CONDUCTORS TOTAL
FIBER (F) ; STEEL (S) STL PVC COATED T POWER (P) - CONTROL (C); GROUND (G) QTY
(SP) Y - INSTRUMENT (I)
PVC (P) P REMARKS
E
LENGTH
Ft / m
NO. & SIZE INSULATION FEET
BENDS
TYPE VOLTS METER
P/G 1-3/C-6 mm2 CU/XLPE 600V 70 DIRECT BURIED (ARMORED)
/PVC
RAS TANURA
SAUDI ARABIA
OPOSAL
PLANT NO. INDEX DRAWING NUMBER SHEET NO.
TO BE USED FOR CONSTRUCTION UNTIL CERTIFIED
M90 P PD-14P104 001
REMARKS
CT BURIED (ARMORED)
CT BURIED (ARMORED)
ANY
DWG. TYPE
CCS
REV. NO.
B
LOAD GLAND TYPE
HP "FROM"
OR END
CONDUIT
NUMBER
SERVICE
CABLE /
KVA VOLTS
PC-0484 SPARE
PC-0485 SPARE
PC-0486 SPARE
PC-0487 SPARE
PC-0488 SPARE
PC-0489 SPARE
PC-0490 SPARE
PC-0491 SPARE
PC-0492 SPARE
PC-0493 SPARE
PC-0494 SPARE
PC-0495 SPARE
PC-0496 SPARE
PC-0497 SPARE
PC-0498 SPARE
PC-0499 SPARE
PC-0500 SPARE
LEGEND : NOTE
C - Conduit (Per SAES-P-104)
CC - Electrical Control (Per SAES-P-104) PC - Power Cable (Per SAES-P-104)
IC - Instrument Cable (Per SAES-J-902)
REFERENCE DRAWING
DWG. CONTROL FOR J.O.10-00965-0001
PANELBOARD SCHEDULE
GLAND TYPE RUN CONDUITS
" TO " TY FIBER (F) ; STEEL (S) STL P
PE (SP)
END
PVC (P)
FROM TO
SIZE
REFERENCE DRAWING
965-0001 PD-00ADCL
PA-15P103 REV. NO. DATE REVISION DESCRIPTION
B 12/'05/2019 ISSUED FOR 100% PROJ. PROPOSAL
JOB ORDER / EWO NO. THIS REVISION IS NOT TO BE USED FOR CONSTRUCTION
10-00965-0001 AND DATED
CONDUITS CONDUCTORS TOTAL
FIBER (F) ; STEEL (S) STL PVC COATED T POWER (P) - CONTROL (C); GROUND (G) QTY
(SP) Y - INSTRUMENT (I)
PVC (P) P REMARKS
E
LENGTH
Ft / m
NO. & SIZE INSULATION FEET
BENDS
TYPE VOLTS METER
P/G 1-3/C-6 mm2 CU/XLPE 600V 37 DIRECT BURIED (ARMORED)
/PVC
RAS TANURA
SAUDI ARABIA
OSAL
PLANT NO. INDEX DRAWING NUMBER SHEET NO.
TO BE USED FOR CONSTRUCTION UNTIL CERTIFIED
M90 P PD-15P104 001
REMARKS
CT BURIED (ARMORED)
CT BURIED (ARMORED)
CT BURIED (ARMORED)
ANY
DWG. TYPE
CCS
REV. NO.
B
LOAD GLAND TYPE
HP "FROM"
OR END
CONDUIT
NUMBER
SERVICE
CABLE /
KVA VOLTS
PC-0508 SPARE
PC-0509 SPARE
PC-0510 SPARE
PC-0511 SPARE
PC-0512 SPARE
PC-0513 SPARE
PC-0514 SPARE
PC-0515 SPARE
PC-0516 SPARE
PC-0517 SPARE
PC-0518 SPARE
PC-0519 SPARE
PC-0520 SPARE
LEGEND : NOTE
C - Conduit (Per SAES-P-104)
CC - Electrical Control (Per SAES-P-104) PC - Power Cable (Per SAES-P-104)
IC - Instrument Cable (Per SAES-J-902)
REFERENCE DRAWING
DWG. CONTROL FOR J.O.10-00965-0001
ELECTRICAL ONE LINE DIAGRAM
CABLE ROUTING LAYOUT
GLAND TYPE RUN CONDUITS
" TO " TY FIBER (F) ; STEEL (S) STL P
PE (SP)
END
PVC (P)
FROM TO
SIZE
PB-1S1A 056-DSW(D)-008
056-PP-004 056-DSW(D)-010
DISCONNECT SWITCH
REVISION VALIDATION
THIS REVISION NO. B
IS COVERED, FOR ALL APPROVAL AND CERTIFICATION REQUIREMENTS
UNDER DRAWING COMPLETION CERTIFICATE NO:
10-00965-0001-001
REFERENCE DRAWING
965-0001 PD-00ADCL
AM PA-16P402 REV. NO. DATE REVISION DESCRIPTION
B 12/05/2019 ISSUED FOR 100% PROJECT PROPOSAL
PA-16P401
JOB ORDER / EWO NO. THIS REVISION IS NOT TO BE USED FOR CONSTRUCTION
10-00965-0001 AND DATED
CONDUITS CONDUCTORS TOTAL
FIBER (F) ; STEEL (S) STL PVC COATED T POWER (P) - CONTROL (C); GROUND (G) QTY
(SP) Y - INSTRUMENT (I)
PVC (P) P REMARKS
E
LENGTH
Ft / m
NO. & SIZE INSULATION FEET
BENDS
TYPE VOLTS METER
P 1-4/C-50 mm2 CU/XLPE 600V 122 DIRECT BURIED (ARMORED)
/PVC
G 1/C-25 mm2 CU/PVC 600V 122
P 1-4/C-50 mm2 CU/XLPE 600V 5
/PVC
G 1/C-25 mm2 CU/PVC 600V 5
P 1-4/C-35 mm2 CU/XLPE 600V 5
/PVC
G 1/C-16 mm2 CU/PVC 600V 5
P 1-3/C- 6 mm2 CU/XLPE 600V 10
/PVC
G 1/C- 6 mm2 CU/PVC 600V 10
P 1-3/C- 6 mm2 CU/XLPE 600V 2
/PVC
G 1/C- 6 mm2 CU/PVC 600V 2
P 1-3/C-4 mm2 CU/XLPE 600V 10
/PVC
G 1/C- 4 mm2 CU/PVC 600V 10
P 1-3/C-4 mm2 CU/XLPE 600V 5
/PVC
G 1/C- 4 mm2 CU/PVC 600V 5
TION SAUDI ARABIAN OIL COMPANY
RTIFICATION REQUIREMENTS, PER SAEP-334,
CERTIFICATE NO: DWG. TYPE
01
CCS
CABLE & CONDUIT SCHEDULE
RAS TANURA
SAUDI ARABIA
OPOSAL
PLANT NO. INDEX DRAWING NUMBER SHEET NO.
TO BE USED FOR CONSTRUCTION UNTIL CERTIFIED
056 P PD-16P407 001
REMARKS
CT BURIED (ARMORED)
ANY
DWG. TYPE
CCS
REV. NO.
B
LOAD GLAND TYPE
HP "FROM"
OR END
CONDUIT
NUMBER
SERVICE
CABLE /
KVA VOLTS
PC-0768 SPARE
PC-0769 SPARE
PC-0770 SPARE
PC-0771 SPARE
PC-0772 SPARE
PC-0773 SPARE
PC-0774 SPARE
PC-0775 SPARE
PC-0776 SPARE
PC-0777 SPARE
PC-0778 SPARE
PC-0779 SPARE
PC-0780 SPARE
LEGEND : NOTE
C - Conduit (Per SAES-P-104)
CC - Electrical Control (Per SAES-P-104) PC - Power Cable (Per SAES-P-104)
IC - Instrument Cable (Per SAES-J-902)
REFERENCE DRAWING
DWG. CONTROL FOR J.O.10-00965-0001
PANELBOARD SCHEDULE
CABLE ROUTING LAYOUT
GLAND TYPE RUN CONDUITS
" TO " TY FIBER (F) ; STEEL (S) STL P
PE (SP)
END
PVC (P)
FROM TO
SIZE
X18-PP-001 X18-DSW(D)-003
REFERENCE DRAWING
965-0001 PD-00ADCL
PA-20P334 REV. NO. DATE REVISION DESCRIPTION
B 12/5/2019 ISSUED FOR 100% PROJECT PROPOSAL
PA-20P337
JOB ORDER / EWO NO. THIS REVISION IS NOT TO BE USED FOR CONSTRUCTION
10-00965-0001 AND DATED
CONDUITS CONDUCTORS TOTAL
FIBER (F) ; STEEL (S) STL PVC COATED T POWER (P) - CONTROL (C); GROUND (G) QTY
(SP) Y - INSTRUMENT (I)
PVC (P) P REMARKS
E
LENGTH
Ft / m
NO. & SIZE INSULATION FEET
BENDS
TYPE VOLTS METER
P 1-4/C-35 mm2 CU/XLPE 600V 100 DIRECT BURIED (ARMORED)
/PVC
G 1/C-16 mm2 CU/PVC 600V 100
P 1-4/C-35 mm2 CU/XLPE 600V 10 DIRECT BURIED (ARMORED)
/PVC
G 1/C-16 mm2 CU/PVC 600V 10
P 1-4/C-35 mm2 CU/XLPE 600V 10
/PVC
G 1/C-16 mm2 CU/PVC 600V 10
P 1-3/C-10 mm2 CU/XLPE 600V 10 DIRECT BURIED (ARMORED)
/PVC
G 1/C-10 mm2 CU/PVC 600V 10
P 1-3/C-10 mm2 CU/XLPE 600V 2 DIRECT BURIED (ARMORED)
/PVC
G 1/C-10 mm2 CU/PVC 600V 2
P 1-3/C-10 mm2 CU/XLPE 600V 10
/PVC
G 1/C-10 mm2 CU/PVC 600V 10
P 1-3/C-6 mm2 CU/XLPE 600V 2
/PVC
G 1/C-4 mm2 CU/PVC 600V 2
TION SAUDI ARABIAN OIL COMPANY
RTIFICATION REQUIREMENTS, PER SAEP-334,
CERTIFICATE NO: DWG. TYPE
01
CCS
CABLE & CONDUIT SCHEDULE
RAS TANURA
SAUDI ARABIA
OPOSAL
PLANT NO. INDEX DRAWING NUMBER SHEET NO.
TO BE USED FOR CONSTRUCTION UNTIL CERTIFIED
X18 O PD-20P336 001
REMARKS
CT BURIED (ARMORED)
CT BURIED (ARMORED)
CT BURIED (ARMORED)
CT BURIED (ARMORED)
ANY
DWG. TYPE
CCS
REV. NO.
B
LOAD GLAND TYPE
HP "FROM"
OR END
CONDUIT
NUMBER
SERVICE
CABLE /
KVA VOLTS
PC-0823 SPARE
PC-0824 SPARE
PC-0825 SPARE
PC-0826 SPARE
PC-0827 SPARE
PC-0828 SPARE
PC-0829 SPARE
PC-0830 SPARE
PC-0831 SPARE
PC-0832 SPARE
PC-0833 SPARE
PC-0834 SPARE
PC-0835 SPARE
PC-0836 SPARE
PC-0837 SPARE
PC-0838 SPARE
PC-0839 SPARE
PC-0840 SPARE
LEGEND : NOTE
C - Conduit (Per SAES-P-104)
CC - Electrical Control (Per SAES-P-104) PC - Power Cable (Per SAES-P-104)
IC - Instrument Cable (Per SAES-J-902)
REFERENCE DRAWING
DWG. CONTROL FOR J.O.10-00965-0001
PANELBOARD SCHEDULE
GLAND TYPE RUN CONDUITS
" TO " TY FIBER (F) ; STEEL (S) STL P
PE (SP)
END
PVC (P)
FROM TO
SIZE
REFERENCE DRAWING
965-0001 PD-00ADCL
PA-22P102 REV. NO. DATE REVISION DESCRIPTION
B 12/5/2019 ISSUED FOR 100% PROJECT PROPOSAL
JOB ORDER / EWO NO. THIS REVISION IS NOT TO BE USED FOR CONSTRUCTION
10-00965-0001 AND DATED
CONDUITS CONDUCTORS TOTAL
FIBER (F) ; STEEL (S) STL PVC COATED T POWER (P) - CONTROL (C); GROUND (G) QTY
(SP) Y - INSTRUMENT (I)
PVC (P) P REMARKS
E
LENGTH
Ft / m
NO. & SIZE INSULATION FEET
BENDS
TYPE VOLTS METER
P/G 1-3/C-16 mm2 CU/XLPE 600V 60 DIRECT BURIED (ARMORED)
/PVC
TANAJIB
SAUDI ARABIA
OPOSAL
PLANT NO. INDEX DRAWING NUMBER SHEET NO.
TO BE USED FOR CONSTRUCTION UNTIL CERTIFIED
M90 P PD-22P103 001
REMARKS
CT BURIED (ARMORED)
CT BURIED (ARMORED)
ANY
DWG. TYPE
CCS
REV. NO.
B
LOAD GLAND TYPE
HP OR "FROM" " TO "
KVA END END
CONDUIT
NUMBER
SERVICE
CABLE /
VOLTS FROM
NEAR PIPELI
PC-0862 POWER 103 KVA 400 V M90-
480V-400/230V TR
PC-0863 POWER 89.53 KVA 400 V M90-ATS-
AUTO TRANS
PC-0864 POWER 4.32 KVA 400 V M90-PP-0
POW
POW
PC-0866 POWER 11.26 KVA 230 V M90-PP-0
POW
PC-0867 POWER 6.0 KW 400 V M90-PP-0
POW
PC-0868 POWER 6.0 KW 400 V M90-
DISCONN
POW
PC-0870 POWER 30 KW 400 V M90-
DISCONN
PC-0871 POWER 6.0 KW 400 V M90-PP-0
POW
PC-0872 POWER 6.0 KW 400 V M90-
DISCONN
EMERGENCY DIESEL
PC-0874 POWER 103 KVA 400 V M90-ECB-
ENCLOSED CIRC
PC-0875 POWER 1.6 KVA 120 V LPG
EXISTING LIG
PC-0876 POWER 0.12 KVA 120 V LPG
EXISTING LIG
PC-0877 SPARE
PC-0878 SPARE
PC-0879 SPARE
PC-0880 SPARE
LEGEND : NOTE
C - Conduit (Per SAES-P-104)
CC - Electrical Control (Per SAES-P-104) PC - Power Cable (Per SAES-P-104)
IC - Instrument Cable (Per SAES-J-902)
REFERENCE DRAWING
DWG. CONTROL FOR J.O.10-00965-0001
ELECTRICAL ONE LINE DIAGRAM
CABLE ROUTING LAYOUT
RUN CONDUITS COND
TY FIBER (F) ; STEEL (S) STL PVC COATED TYP
PE (SP) E
PVC (P)
FROM TO
LENGTH
SIZE Ft / m BENDS
M90-PP-001 M90-PP-002 P
M90-PP-001 M90-DSW(D)-003 P
DISCONNECT SWITCH G
M90-EDG-001 M90-ATS-001 P
REVISION VALIDATION
THIS REVISION NO. C
IS COVERED, FOR ALL APPROVAL AND CERTIFICATION REQUIREMENTS, PER SAEP-334,
UNDER DRAWING COMPLETION CERTIFICATE NO:
10-00965-0001-001
E DRAWING
PD-00ADCL
PA-24P502 REV. NO. DATE REVISION DESCRIPTION
C 1/7/2020 ISSUED FOR 100% PROJECT. PROPOSAL
PA-24P501
JOB ORDER / EWO NO. THIS REVISION IS NOT TO BE USED FOR CONSTRUCTION UNTIL CERTIFIED
10-00965-0001 AND DATED
CONDUCTORS TOTAL
POWER (P) - CONTROL (C); GROUND (G) QTY
- INSTRUMENT (I)
REMARKS
NO. & SIZE INSULATION FEET
TYPE VOLTS METER
1-3/C-120 mm2 CU/XLPE 6KV 500 DIRECT BURIED (ARMORED)
SWA/PVC
CCS
CABLE & CONDUIT SCHEDULE
PC-0861 PC-0880
NUMBER THROUGH
KVA VOLTS
PC-0923 SPARE
PC-0924 SPARE
PC-0925 SPARE
PC-0926 SPARE
PC-0927 SPARE
PC-0928 SPARE
PC-0929 SPARE
PC-0930 SPARE
PC-0931 SPARE
PC-0932 SPARE
PC-0933 SPARE
PC-0934 SPARE
PC-0935 SPARE
PC-0936 SPARE
PC-0937 SPARE
PC-0938 SPARE
PC-0939 SPARE
PC-0940 SPARE
LEGEND : NOTE
C - Conduit (Per SAES-P-104)
CC - Electrical Control (Per SAES-P-104) PC - Power Cable (Per SAES-P-104)
IC - Instrument Cable (Per SAES-J-902)
REFERENCE DRAWING
DWG. CONTROL FOR J.O.10-00965-0001
PANELBOARD SCHEDULE
GLAND TYPE RUN CONDUITS
" TO " TY FIBER (F) ; STEEL (S) STL P
PE (SP)
END
PVC (P)
FROM TO
SIZE
REFERENCE DRAWING
965-0001 PD-00ADCL
PA-26P102 REV. NO. DATE REVISION DESCRIPTION
B 12/05/2019 ISSUED FOR 100% PROJECT PROPOSAL
JOB ORDER / EWO NO. THIS REVISION IS NOT TO BE USED FOR CONSTRUCTION
10-00965-0001 AND DATED
CONDUITS CONDUCTORS TOTAL
FIBER (F) ; STEEL (S) STL PVC COATED T POWER (P) - CONTROL (C); GROUND (G) QTY
(SP) Y - INSTRUMENT (I)
PVC (P) P REMARKS
E
LENGTH
Ft / m
NO. & SIZE INSULATION FEET
BENDS
TYPE VOLTS METER
P/G 1-3/C-6 mm2 CU/XLPE 600V 34 DIRECT BURIED (ARMORED)
/PVC
MANIFA
SAUDI ARABIA
OPOSAL
PLANT NO. INDEX DRAWING NUMBER SHEET NO.
TO BE USED FOR CONSTRUCTION UNTIL CERTIFIED
Q42 P PD-26P103 001
REMARKS
CT BURIED (ARMORED)
CT BURIED (ARMORED)
ANY
DWG. TYPE
CCS
REV. NO.
B
LOAD GLAND TYPE
HP "FROM"
OR END
CONDUIT
NUMBER
SERVICE
CABLE /
KVA VOLTS
PC-0943 SPARE
PC-0944 SPARE
PC-0945 SPARE
PC-0946 SPARE
PC-0947 SPARE
PC-0948 SPARE
PC-0949 SPARE
PC-0950 SPARE
PC-0951 SPARE
PC-0952 SPARE
PC-0953 SPARE
PC-0954 SPARE
PC-0955 SPARE
PC-0956 SPARE
PC-0957 SPARE
PC-0958 SPARE
PC-0959 SPARE
PC-0960 SPARE
LEGEND : NOTE
C - Conduit (Per SAES-P-104)
CC - Electrical Control (Per SAES-P-104) PC - Power Cable (Per SAES-P-104)
IC - Instrument Cable (Per SAES-J-902)
REFERENCE DRAWING
DWG. CONTROL FOR J.O.10-00965-0001
PANELBOARD SCHEDULE
GLAND TYPE RUN CONDUITS
" TO " TY FIBER (F) ; STEEL (S) STL P
PE (SP)
END
PVC (P)
FROM TO
SIZE
REFERENCE DRAWING
965-0001 PD-00ADCL
PA-27P102 REV. NO. DATE REVISION DESCRIPTION
B 12/05/2019 ISSUED FOR 100% PROJECT PROPOSAL
JOB ORDER / EWO NO. THIS REVISION IS NOT TO BE USED FOR CONSTRUCTION
10-00965-0001 AND DATED
CONDUITS CONDUCTORS TOTAL
FIBER (F) ; STEEL (S) STL PVC COATED T POWER (P) - CONTROL (C); GROUND (G) QTY
(SP) Y - INSTRUMENT (I)
PVC (P) P REMARKS
E
LENGTH
Ft / m
NO. & SIZE INSULATION FEET
BENDS
TYPE VOLTS METER
P/G 1-3/C-4 mm2 CU/XLPE 600V 40 DIRECT BURIED (ARMORED)
/PVC
WASIT
SAUDI ARABIA
OPOSAL
PLANT NO. INDEX DRAWING NUMBER SHEET NO.
TO BE USED FOR CONSTRUCTION UNTIL CERTIFIED
M90 P PD-27P103 001
REMARKS
CT BURIED (ARMORED)
CT BURIED (ARMORED)
ANY
DWG. TYPE
CCS
REV. NO.