Professional Documents
Culture Documents
Wika - Electrical Thermometers - 2003
Wika - Electrical Thermometers - 2003
Temperature Measurement
Applications
Special Features
T Robust
T Media temperature up to 850 °C with thermocouples,
up to 600 °C with resistance thermometers
T DNV, GL and LR approval with thermocouples,
DNV approval with resistance thermometers
Basic values and limiting errors Available as simplex thermocouple. The hot junction of the
Basic values and limiting errors for the platinum measuring probe is supplied ungrounded.
resistors are laid down in DIN EN 60 751.
The nominal value of Pt 100 sensors is 100 Ω at 0 °C. The
temperature coefficient α can be stated simply to be
between 0 °C and 100 °C with:
The limiting errror is defined for two classes: Type K DIN EN 60 584 part 2
Ω
2.0 B in 1.0
ss Limiting error with selected temperatures in °C
cla
Error in Ω
Error in °C
Neck
Process connection
Thermowell
3376 139.01
Legend:
E Thread
M H Neck length
U 1 Insertion length
Model TR293
3160 629.05
red red
red red red
Model TC293
3166 822.02
When connecting to
the terminals, please
refer to the colour
coding on table below.
2 2 wire
3 3 wire
2 4 4 wire
Process connection
GE G 3/4 B
3 ?? other please state as additional text
Neck length
B 50 mm
C 100 mm
4 ? other please state as additional text
Insertion length
0202 202 mm
0100 100 mm
0150 150 mm
0250 250 mm
5 length in mm, e.g. 0850 for 850 mm
Connection head
O model BS (aluminium, epoxy coated)
P model BSZ (aluminium, epoxy coated)
Q model BSZ-H (aluminium, epoxy coated)
R model KNE (aluminium, epoxy coated)
6 model BSK (plastic)
6 8 model BVA (stainless steel)
Order code:
1 2 3 4 5 6 7
TR293 - Z - - - ZZ -
Additional text:
Order code:
1 2 3 4 5 6
TC293 - Z - - - ZZ -
Additional text:
Specifications and dimensions given in this leaflet represent the state of engineering at the time of printing.
Modifications may take place and materials specified may be replaced by others without prior notice.
9066837 08/2003 GB