testRNC> h
1 How do you print the list of available commands in OSE shell of the
current board?
testRNC> ?
3 How do you print the user variables? What is the path to the java
software used by this moshell installation? What is the value of the
setting “corba_class”?
testRNC> uv
bldebset_confirmation = 1
credential = C:/cygwin/home/eniaosh/moshell/commonjars/host.p12
corba_class = 2
corba_debug = 0
corba_timeout = 240
corba_connection_timeout = 90
csnotiflist = availabilitystatus
custom_param_file =
decoder = /vobs/iov/rnc/bin/decoder.pl
default_mom = /home/eniaosh/moshell/jarxml/MGW_R2.xml
…..
ip_database = /home/eniaosh/moshell/sitefiles/ipdatabase
ip_inactivity_timeout = 45
java = /cygdrive/c/Windows/system32/java
jarxmldir = /home/eniaosh/moshell/jarxml
…….
testRNC> pv moshell
$moshelldir = /home/eniaosh/moshell
$moshell_version = 8.0h
5 How do you print the release history for this version of AMOS?
testRNC> h 0
###################################################################################
#########
Revision History
###################################################################################
#########
////////////////////////////////////////////////
CHANGES IN v8.0h (2010-06-25)
////////////////////////////////////////////////
……
6 How can you see the relation between the MOM version and the node’s
SW release?
testRNC> upid
7 How do you print the syntax information for the command "mom"?
testRNC> h mom
*******************************************************
mom[aptcdbrflou] [<moclass/struct/enum>] [<attribute/action>] [<attr-type>] [<attr-
flags>] [<description>]
*******************************************************
Print description of MO classes, CM/FM attributes, actions, enums and structs.
Options:
- "a" : show only the definitions relating to application MOs
- "p" : show only the definitions relating to platform MOs (CPP)
- "c" : show all the MO classes specified in the filter as well as their
children/grandchildren/etc classes.
- "t" : show the whole MO tree with parent-children relationships and cardinality.
The options o and u can be used to show only
the MOs over or under.
- "d" : gives a shorter printout, without the description part.
- "b" : shows the default attribute values.
- "r" : shows the valid attribute value range.
##################################################################################
Enum Values
##################################################################################
LedStatus 0:NOT_APPLICABLE, 1:NOT_AVAILABLE, 2:OUT,
3:STEADY_LIGHT, 4:SLOW_BLINK,
5:FAST_BLINK, 6:FLICKERING
Enter a second argument in the mom command for more detailed description (or type
"h mom" for help).
##################################################################################
Enum Values
##################################################################################
LedStatus 0:NOT_APPLICABLE, 1:NOT_AVAILABLE, 2:OUT,
3:STEADY_LIGHT, 4:SLOW_BLINK,
5:FAST_BLINK, 6:FLICKERING
----------------------------------------------------------------------------------
Possible states for green, yellow and red LEDs.
- NOT_APPLICABLE: This MO does not support LED states.
- NOT_AVAILABLE: The LED state is not available at the moment.
- OUT: Depends on the color of the LED. See the description of the corresponding
LED status attribute.
- STEADY_LIGHT: Depends on the color of the LED. See the description of the
corresponding LED status attribute.
- SLOW_BLINK: Depends on the color of the LED. See the description of the
corresponding LED status attribute.
- FAST_BLINK: Load or test in progress.
- FLICKERING: Busy. See the description of the corresponding LED status attribute.
###################################################################################
#####################
############################
MO Class Attribute Type
Flags
###################################################################################
#####################
############################
OspfInterface helloInterval long
-----------------------------------------------------------------------------------
-------------------------------------------------
The time between sending OSPF Hello-packets over the interface.
This attribute must have a positive value.
Unit: 1 s
Default=10
***********************************************************************************
*********************
****************************
SwitchStp bridgeHelloTime long
-----------------------------------------------------------------------------------
-------------------------------------------------
Interval between periodic transmissions of configuration messages by designated
ports.
###################################################################################
#####################
############################
MO Class Attribute Type
Flags
###################################################################################
#####################
############################
AtmTrafficDescriptor egressAtmPcr long
restricted,noNotification
-----------------------------------------------------------------------------------
-------------------------------------------------
Egress ATM Peak cell rate (cells/s).
Only non-negative values are allowed. This attribute is only mandatory when
serviceCategory is CBR.
When serviceCategory is set to UBR+, egressAtmPcr < egressAtmMcr disables shaping.
egressAtmPcr >= egressAtmMcr
enables shaping to the rate specified.
Default=0
***********************************************************************************
*********************
****************************
AtmTrafficDescriptor ingressAtmPcr long
restricted,noNotification
-----------------------------------------------------------------------------------
-------------------------------------------------
Ingress ATM Peak cell rate (cells/s).
Only non-negative values are allowed. The attribute is only mandatory when
serviceCategory is CBR.
Default=0
***********************************************************************************
**
***************************
11 View the attributes and action list, without description, for all
descriptions containing the word “restart”.
###################################################################################
#####################
############################
MO Class Attribute Type
Flags
###################################################################################
#####################
############################
Mtp3bSpChina restartType
enumRef:RestartType
PiuType defAllowedSeqRestarts
enumRef:SeqRestarts
restricted,noNotification,mandatory
PlugInUnit allowedSeqRestarts
enumRef:SeqRestarts
Program restartCounterLimit long
Program restartTimer long
…..
12 Determine from the MOM the list of MO classes that can be defined
underneath the MO class SccpScrc.
--------------------------------
MO classes over SccpScrc
--------------------------------
TransportNetwork[1],SccpSp[0-24],SccpScrc[1]
--------------------------------
MO classes under SccpScrc
--------------------------------
SccpAccountingCriteria[0-100]
SccpApLocal[0-7]
SccpApRemote[0-200]
SccpEntitySet[0-2048]
SccpGlobalTitle[0-2048]
SccpPolicing[0-1024]
###################################################################################
#####################
############################
MO Class Attribute Type
Flags
###################################################################################
#####################
############################
UpgradePackage state
enumRef:UpgradePackageState readOnly
-----------------------------------------------------------------------------------
-------------------------------------------------
Specifies the state of this upgrade package.
This attribute is used to accept, reject or modify behavior of actions. For
example, the action, upgrade, is not allowed in the state
NOT_INSTALLED.
The action, confirmUpgrade, is called to continue and conclude the upgrade sequence
when state =
AWITING_CONFIRMATION. Then the attribute, confirmationDeadline, is used to check
the time left before automatic rollback
is done.
Upgrade Package MOs that are stored on disk but do not have an MO in the current
CV, are in the state ONLY_DELETEABLE.
An MO in this state only accepts action, updateFTPServerData. If any other type of
action is invoked, the
ActionNotAllowedException is thrown.
Default=NOT_INSTALLED
***********************************************************************************
*********************
****************************
##################################################################################
Enum Values
##################################################################################
Then
===================================================================================
=========
=====================
MO admActiveSlot replication
===================================================================================
=========
=====================
ReliableProgramUniter=12021241491751 Subrack=MS,Slot=17 4
(APPL_CONTROLLED)
ReliableProgramUniter=rnc_cen_agps_central Subrack=MS,Slot=17 4
(APPL_CONTROLLED)
ReliableProgramUniter=rnc_cen_rnh_central Subrack=MS,Slot=17 4
(APPL_CONTROLLED)
ReliableProgramUniter=rnc_cen_mbms_ranap_rnsap Subrack=MS,Slot=17 4
(APPL_CONTROLLED)
===================================================================================
=========
=====================
Total: 4 MOs
===================================================================================
=========
================
Id MO userLabel
Result
===================================================================================
=========
================
312 Equipment=1 RNC195
>>> Set.
===================================================================================
=========
================
Total: 1 MOs attempted, 1 MOs set
22 Generate two moshell scripts that will allow to delete and recreate the
MO Aal2RoutingCase=Iub-10.
testRNC> u+s
Getting Attributes...
===================================================================================
===================================================================================
=========
=====================
MO Attribute Value
===================================================================================
=========
=====================
TransportNetwork=1,Aal2RoutingCase=rbs152 Aal2RoutingCaseId rbs152
TransportNetwork=1,Aal2RoutingCase=rbs152 numberDirection
353000110438152
TransportNetwork=1,Aal2RoutingCase=rbs152 routeList [1] =
>>> routeList = TransportNetwork=1,Aal2Sp=1,Aal2Ap=rbs152
TransportNetwork=1,Aal2RoutingCase=rbs152 routePriorityList i[1] = 1
TransportNetwork=1,Aal2RoutingCase=rbs152 userLabel
===================================================================================
=========
=====================
Total: 1 MOs
Deleting ...
===================================================================================
250 TransportNetwork=1,Aal2RoutingCase=rbs152
>>> Simulated MO deletion
===================================================================================
Total: 1 MOs attempted, 1 MOs deleted
testRNC> u-
Note: to convert command files from moshell format to trun/emas format, execute the
command: u! <commandfile
===================================================================================
=========
=====================
Proxy MO Action
Nr of Params
===================================================================================
=========
=====================
4696 Ip=1,IpRoutingTable=1 listRoutes
0
>>> Return value = 3
destinationIpAddr destinationNetMask nextHopIpAddr routeMetric routeType
interface redistribute active
0.0.0.0 0.0.0.0 159.107.186.129 100 2:LOCAL le0
FALSE active
127.0.0.1 255.255.255.255 127.0.0.1 0 2:LOCAL lo0
FALSE active
159.107.186.128 255.255.255.128 0.0.0.2 0 2:LOCAL le0
FALSE active
===================================================================================
=========
=====================
===================================================================================
=========
=====================
Proxy MO Action
Nr of Params
===================================================================================
=========
=====================
4012 UpgradePackage=CXP9012995_R6EB/24 cancelInstall
0
4012 UpgradePackage=CXP9012995_R6EB/24 cancelUpgrade
0
4012 UpgradePackage=CXP9012995_R6EB/24
clearUpgradeLogFile 0
4012 UpgradePackage=CXP9012995_R6EB/24
confirmUpgrade 0
4012 UpgradePackage=CXP9012995_R6EB/24 forcedInstall
0
4012 UpgradePackage=CXP9012995_R6EB/24 install
0
4012 UpgradePackage=CXP9012995_R6EB/24
nonBlockingForcedInstall 0
4012 UpgradePackage=CXP9012995_R6EB/24
nonBlockingInstall 0
4012 UpgradePackage=CXP9012995_R6EB/24
nonBlockingSelectiveForcedInstall 0
4012 UpgradePackage=CXP9012995_R6EB/24
nonBlockingSelectiveInstall 0
4012 UpgradePackage=CXP9012995_R6EB/24
piuTypeForcedInstall 1
4012 UpgradePackage=CXP9012995_R6EB/24
piuTypeInstall 1
4012 UpgradePackage=CXP9012995_R6EB/24
readSupportedUpgradeTypesStatus 0
4012 UpgradePackage=CXP9012995_R6EB/24
rebootNodeUpgrade 0
4012 UpgradePackage=CXP9012995_R6EB/24
setRequestedTypeOfUP 1
4012 UpgradePackage=CXP9012995_R6EB/24 update
0
4012 UpgradePackage=CXP9012995_R6EB/24
updateFTPServerData 4
4012 UpgradePackage=CXP9012995_R6EB/24 upgrade
0
4012 UpgradePackage=CXP9012995_R6EB/24 verifyUpgrade
0
===================================================================================
======
1 TELNET commands to access CPP node should MOSHELL not be available to GPB :
telnet <Ipaddr of NE>
A) Check the Configuration Versions:
cv cu
cv ls
cv mk
cv set
B) In RXI:
pr .<rbs ID> eg. pr .0095
lk <proxy>
st atmport=ms-x-y
bl
lget ms-2-2 (then check iub number with STR printout – see tally or not)
reservedBy Aal2PathVccTp=b0001a2 <----- iub # = 0001
In RBS (when port is ready but E1 not pull through yet – so that no alarm)
pr atmport
get <proxy> ie. get 1345
lget Subrack=1,Slot=2,PlugInUnit=1,Etm1=1,E1PhysPathTerm=pp2
set <proxy> administrativeState 0 (to lock the 2nd physical port)
set 194 administrativeState 0 (to lock the 2nd physical port)
13 To check RBS MO
A)In RBS
st plug (AuxPlugInUnit=2 is the RET, AuxPlugInUnit=1 is the ASC)
cabx
cab (without the external parts)
15 To lock/unlock cells
In RNC
st utrancell=<cell name>
lst sunw
lbl sunw (to lock cell & channels)
bl sunw (to lock cell only)
deb sunw (to unlock)
20 To autocreateCV
In RNC & RBS
get config
Cv ls (2 CVs will be used for the autocreate CV function)
set “proxy” autoCreatedCVIsTurnedOn true/false
set timeForAutoCreatedCV (UTC time)
set timeForAutoCreatedCV 13:00 (cv autocreated at 9pm)
21 To restart Node
In RNC,RXI & RBS
acc 0 restart
poll (to wait 20seconds until node comes up again)
22 To create CV
In RNC,RXI & RBS
cvms <CV name> YourUserName change_ntpserver_ip
cvms <CV name> followed by comments for the CV
cvset <CV name> -- to set the CV startable
23 To restart node
In RNC & node B
acc 0 restart
poll - to get moshell connected once node has restarted
st plugin 1 0
st plugin 0 1
lst plug 0
29 To check E1 state
In RBS
st atmport
Check port lock state
st pp st pp2 st pp3 st pp4
36 maxDlPowerCapability /maxDl
In RBS
get local xdl
In RBS
get SOGXBU_1 maximumtransmissionpower
37 RBSID
In node RBS
pr iub
get the proxy NodeBFunction=1,Iub=POT3UU
RBSID seen
In node RNC
get iublink userlabel
38 To continuously ping
ping –s 10.78.1.1101
45 To check external Open Door alarm in RBS is set to which probable cause
In node RBS
pr almdevice
get proxy (either 2 / 1 or 9)
Usually 9 for RBS door and 2 for BBU door
Some put 1 for BBU door
get proxy for parameter check
Lock proxy to change probableCause
bl 54
probableCause 522 à power supply
probableCause 118 à enclosure_door_open_m3100
set 54 probableCause 118
then unlock back proxy
deb 54
General Problem’.