Professional Documents
Culture Documents
If bored pile is selected then, following types of bored pile is suitable to support
structural foundation. Bored pile can be different sizes to reduce number of pile
and smaller pile cap (single or double pile)
At least 1 load test is required for maximum size uses to twice the working load
Project : CADANGAN MEMBINA BLOK TAMBAHAN JABATAN KIMIA MALAYSIA
CAWANGAN BINTULU, SARAWAK
1 Basic Data:
2 Structural Capacity :
3.2 Bond between concrete and hard soil (N>50) n/mm2 0.3
3.3 Bond between grout and soil (N<50) 0.01N
3.4 Ultimate pile capacity per meter penetration into rock KN 566
3.5 Ultimate unit End Bearing , Hard soil (N>50) KN/m2 9000
D BUILDING
Remarks
40
490.9375
297.54524
600-150
>2000 OK
provide 6.0m
refer to BH log
Project : CADANGAN MEMBINA BLOK TAMBAHAN JABATAN KIMIA MALAYSIA
CAWANGAN BINTULU, SARAWAK
1 Basic Data:
2 Structural Capacity :
3.2 Bond between concrete and hard soil (N>50) n/mm2 0.3
3.3 Bond between grout and soil (N<50) 0.01N
3.4 Ultimate pile capacity per meter penetration into rock KN 707
3.5 Ultimate unit End Bearing , Hard soil (N>50) KN/m2 9000
D BUILDING
Remarks
40
490.9375
297.54524
750-150
>3000 OK
provide 7.0m
refer to BH log
Project : CADANGAN MEMBINA BLOK TAMBAHAN JABATAN KIMIA MALAYSIA
CAWANGAN BINTULU, SARAWAK
1 Basic Data:
2 Structural Capacity :
3.2 Bond between concrete and hard soil (N>50) n/mm2 0.3
3.3 Bond between grout and soil (N<50) 0.01N
3.4 Ultimate pile capacity per meter penetration into rock KN 189
3.5 Ultimate unit End Bearing , Hard soil (N>50) KN/m2 9000
D BUILDING
Remarks
40
490.9375
297.54524
600-150
>1500 OK
provide 5.0m
refer to BH log