GUIDELINE FOR STRUCTURE ANALYSIS

1
Rev Date Description Prepared By Approved By
00 6/12/19 Design parameters for structure Nik Fairuz Nik Kamarul
analysis using TIA-222-G
01 25/2/20 Guideline for strengthening Nik Fairuz Nik Kamarul
proposal

2
DESIGN PARAMETERS FOR STRUCTURAL ANALYSIS

Design Wind Speed 120 km/h (33.33 m/s)


Operational Wind Speed 108 km/h (30 m/s)
Design Code TIA-222-G
should be as per site actual data
Exposure Category (cl 2.6.5)
analysis and visual information as at
Topographic Category (cl 2.6.6.2) site
Classification of Structure (Table 2-1) Fixed to Class II
Load Combination (cl 2.3.2) 1.2DL + 1.6WL and 0.9DL + 1.6WL
Deflection Limits < 0.5 for tower / 1.0 degree for pole
Analysis Software MS Tower V6.2 (Latest version)

3
Exposure Category (cl 2.6.5)

4
Exposure Category - Exposure B

5
Exposure Category - Exposure C

6
Exposure Category - Exposure D

7
Topographic Category (cl 2.6.6.2)

8
Topographic Categories

9
Topographic Features

10
STRENGTHENING PROPOSAL

➢ Strengthening proposal to propose minimum member thickness = 4mm

➢ Strengthening proposal to add strut members instead of adding/replace


guy wire for rooftop sites