You are on page 1of 7

Procedure of Re-install MDU Vent Duct

1. Re-install the MDU Ventilation Duct

1) Cut off and disconnect the piping and the electrical wiring
2) Remove the MDU VENT DUCT
3) Remove the existing radiator.

Remove the existing radiator.


4)  Assemble the duct as shown in paragraph 2.
5) Connect duct to duct as shown in paragraph 3.
6) Assemble the duct support as shown in paragraph 4.
7) Re-assemble the radiator and the mdu as shown below.

(Refer to the dwg no. BRF3-002-P0023)

 
2. Assembling of Duct
(1) Formation and Assembling of Duct
Panels of duct are formation of a female panel and a male panel.

male panel

Figure 1 

female panel

Figure 2 

Work 1 Insert a wing part of a male panel with a male part like
 
 
 
 
  Wing of male panel
 
 
 
 
 
 
 
 
  Figure 3 
 
 
   

 
 
Work 2 Strke a wing of male panel for fixing panel like figure 3

 
 
 
 
 
 
 
Figure 4 
 
 
Duct set is completed to repeat work 1 and work2
 
(2)Finishing of Duct 
 
 
 
 
 
 
 
 
  Figure 5 
 
 
          Duct is finishing by figure 5 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Figure 6 
 
 
Put a parts(figure 5) on end of duct. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
  Figure 7 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
  Figure 8 
 
 
 
 
Work 3 Bending plate make use of penchi. And than flatten out by hummer.
 
 
 
 
 
 
 
 
3. Connection Duct to Duct
 
Please follow the procedure below to connect to the existing duct.
 
 
 
 
  Figure 9
 
 
 
 
The joint clips shown in Figure 9
are used for duct connections.
 
 
 
 
 
 
 
 
  SPECIAL TOOL
 
 
  Figure 10
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
  Figure 11  Figure 12 
 
 
 
 
         
1. Insert the sponge gasket between the flange of the existing duct and the flange of the new duct.
2. Take Clip by special tool - figure10
and push the tool for fixing duct like figure11,12
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
  Figure 13 
 
 
 
 
 
3. Secure the duct by clip and then fix the corner with M10 bolts.
(refer to figure 13)

 
Vent Duct Support
 
 
 
4. Assembling of Duct Support  
(1) Formation and Assembling of Duct Support  
   
   
Assemble the duct support as shown below.  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Figure 12 
 
 
 
 
 
 
 
 
 
 
1 . As shown in Figure 12, assemble the parts and make them.
Use M12*40L (B/N/2PW/SW) for assembly bolts of Duct Support.
 
 
2. As shown in the following Duct & Support Drawings, each support can be
assembled according to its designated location.
Use M12*40L (B/N/2PW/SW) for the assembly bolts of Support
and Equipment.
 
 
 
 
 

 
(

BRF3-002-P0023 1/1