Professional Documents
Culture Documents
/HYHO )ODUHWRROIRU55$
6FDOH *DXJHPDQLIROGIRU55$
Model names are indicated in 1-3. 8WLOLW\NQLIHRUVFLVVRUV 9DFXXPSXPSIRU55$
63/,77<3($,5&21',7,21(56 PPKROHVDZ &KDUJHKRVHIRU55$
7RUTXHZUHQFK 3LSHFXWWHUZLWKUHDPHU
INSTALLATION MANUAL :UHQFKRUVSDQQHU
$SSURSULDWHSHUVRQDOSURWHFWLYHHTXLSPHQW
7KHLQVWDOOHUVVKRXOGHQVXUHWKH\FKHFNWKHUHVSHFWLYH:RUN+HDOWK
DQG6DIHW\:+6$FWZLWKLQWKHLUMXULVGLFWLRQDVWKHUHTXLUHPHQWV
DQGREOLJDWLRQVPD\GLIIHU
1. BEFORE INSTALLATION
MEANINGS OF SYMBOLS DISPLAYED ON INDOOR UNIT AND/OR OUTDOOR UNIT
WARNING 7KLVXQLWXVHVDÀDPPDEOHUHIULJHUDQW
5LVNRI¿UH ,IUHIULJHUDQWOHDNVDQGFRPHVLQFRQWDFWZLWK¿UHRUKHDWLQJSDUWLWZLOOFUHDWHKDUPIXOJDVDQGWKHUHLVULVNRI¿UH
5HDGWKH23(5$7,1*,16758&7,216FDUHIXOO\EHIRUHRSHUDWLRQ
6HUYLFHSHUVRQQHODUHUHTXLUHGWRFDUHIXOO\UHDGWKH23(5$7,1*,16758&7,216DQG,167$//$7,210$18$/EHIRUHRSHUDWLRQ
)XUWKHULQIRUPDWLRQLVDYDLODEOHLQWKH23(5$7,1*,16758&7,216,167$//$7,210$18$/DQGWKHOLNH
WARNING &RXOGOHDGWRGHDWKVHULRXVLQMXU\HWF
■ Do not install the unit by yourself (user). ■ Be sure to use the parts provided or speci¿ed parts ■ When installing the unit, securely connect the refriger-
,QFRPSOHWH LQVWDOODWLRQ FRXOG FDXVH ¿UH HOHFWULF VKRFN for the installation work. ant pipes before starting the compressor.
LQMXU\GXHWRWKHXQLWIDOOLQJRUOHDNDJHRIZDWHU&RQVXOW 7KHXVHRIGHIHFWLYHSDUWVFRXOGFDXVHDQLQMXU\RUOHDNDJH ,IWKHFRPSUHVVRULVVWDUWHGEHIRUHWKHUHIULJHUDQWSLSHVDUH
WKHGHDOHUIURPZKRP\RXSXUFKDVHGWKHXQLWRUDTXDOL¿HG RIZDWHUGXHWRD¿UHDQHOHFWULFVKRFNWKHXQLWIDOOLQJ FRQQHFWHGDQGZKHQWKHVWRSYDOYHLVRSHQDLUFRXOGEH
LQVWDOOHU HWF GUDZQLQDQGWKHSUHVVXUHLQWKHUHIULJHUDWLRQF\FOHFRXOG
■ Perform the installation securely referring to the ■ When plugging the power supply plug into the outlet, EHFRPHDEQRUPDOO\KLJK7KLVFRXOGFDXVHWKHSLSHVWR
installation manual. make sure that there is no dust, clogging, or loose EXUVWRULQMXU\
,QFRPSOHWH LQVWDOODWLRQ FRXOG FDXVH ¿UH HOHFWULF VKRFN parts in both the outlet and the plug. Make sure that ■ Fasten a Àare nut with a torque wrench as speci¿ed
LQMXU\GXHWRWKHXQLWIDOOLQJRUOHDNDJHRIZDWHU the power supply plug is pushed completely into the in this manual.
■ When installing the unit, use appropriate protective outlet. ,IIDVWHQHGWRRWLJKWDÀDUHQXWPD\EUHDNDIWHUDORQJ
equipment and tools for safety. ,I WKHUH LV GXVW FORJJLQJ RU ORRVH SDUWV RQ WKH SRZHU SHULRGDQGFDXVHUHIULJHUDQWOHDNDJH
)DLOXUHWRGRVRFRXOGFDXVHLQMXU\ VXSSO\SOXJRUWKHRXWOHWLWFRXOGFDXVHHOHFWULFVKRFNRU ■ The unit shall be installed in accordance with national
■ Install the unit securely in a place which can bear the ¿UH,IORRVHSDUWVDUHIRXQGRQWKHSRZHUVXSSO\SOXJ wiring regulations.
weight of the unit. UHSODFHLW ■ When using a gas burner or other Àame-producing
,IWKHLQVWDOODWLRQORFDWLRQFDQQRWEHDUWKHZHLJKWRIWKH ■ Attach the electrical cover to the indoor unit and the equipment, completely remove all of the refrigerant
XQLWWKHXQLWFRXOGIDOOFDXVLQJLQMXU\ service panel to the outdoor unit securely. from the air conditioner and ensure that the area is
■ Electrical work should be performed by a quali¿ed, ,IWKHHOHFWULFDOFRYHURIWKHLQGRRUXQLWDQGRUWKHVHUYLFH well-ventilated.
e[perienced electrician, according to the installation SDQHORIWKHRXWGRRUXQLWDUHQRWDWWDFKHGVHFXUHO\LWFRXOG ,I WKH UHIULJHUDQW OHDNV DQG FRPHV LQ FRQWDFW LQ ¿UH RU
manual. Be sure to use an e[clusive circuit. Do not UHVXOWLQD¿UHRUDQHOHFWULFVKRFNGXHWRGXVWZDWHUHWF KHDWLQJSDUWLWZLOOFUHDWHKDUPIXOJDVDQGWKHUHLVULVNRI
connect other electrical appliances to the circuit. ■ When installing, relocating, or servicing the unit, ¿UH
,IWKHFDSDFLW\RIWKHSRZHUFLUFXLWLVLQVXI¿FLHQWRUWKHUH make sure that no substance other than the speci¿ed
LVLQFRPSOHWHHOHFWULFDOZRUNLWFRXOGUHVXOWLQD¿UHRUDQ refrigerant (R32) enters the refrigerant circuit. ■ Do not use means to accelerate the defrosting process
HOHFWULFVKRFN $Q\SUHVHQFHRIIRUHLJQVXEVWDQFHVXFKDVDLUFDQFDXVH or to clean, other than those recommended by the
■ Earth the unit correctly. DEQRUPDO SUHVVXUH ULVH DQG PD\ UHVXOW LQ H[SORVLRQ RU manufacturer.
'RQRWFRQQHFWWKHHDUWKWRDJDVSLSHZDWHUSLSHOLJKW- LQMXU\7KHXVHRIDQ\UHIULJHUDQWRWKHUWKDQWKDWVSHFL- ■ The appliance shall be stored in a room without
QLQJ URG RU WHOHSKRQH HDUWK 'HIHFWLYH HDUWKLQJ FRXOG ¿HGIRUWKHV\VWHPZLOOFDXVHPHFKDQLFDOIDLOXUHV\VWHP continuously operating ignition sources (for e[am-
FDXVHHOHFWULFVKRFN PDOIXQFWLRQ RU XQLW EUHDNGRZQ ,Q WKH ZRUVW FDVH WKLV ple: open Àames, an operating gas appliance or an
■ Do not damage the wires by applying e[cessive pres- FRXOGOHDGWRDVHULRXVLPSHGLPHQWWRVHFXULQJSURGXFW operating electric heater.
sure with parts or screws. VDIHW\ ■ Do not pierce or burn.
'DPDJHGZLUHVFRXOGFDXVH¿UHRUHOHFWULFVKRFN ■ Do not discharge the refrigerant into the atmosphere. ■ Be aware that refrigerants may not contain an odour.
■ Be sure to cut off the main power in case of setting If refrigerant leaks during installation, ventilate the ■ Pipe-work shall be protected from physical damage.
up the indoor P.C. board or wiring works. room. Check that the refrigerant does not leak after ■ The installation of pipe-work shall be kept to a mini-
)DLOXUHWRGRVRFRXOGFDXVHHOHFWULFVKRFN installation has been completed. mum.
■ Use the speci¿ed wires to connect the indoor and ,IUHIULJHUDQWOHDNVDQGFRPHVLQFRQWDFWZLWK¿UHRUKHDW- ■ Compliance with national gas regulations shall be
outdoor units securely and attach the wires ¿rmly to LQJSDUWRIVXFKDIDQKHDWHUNHURVHQHKHDWHURUFRRNLQJ observed.
the terminal block connecting sections so the stress VWRYHLWZLOOFUHDWHKDUPIXOJDV ■ Keep any required ventilation openings clear of ob-
of the wires is not applied to the sections. Do not ■ Use appropriate tools and piping materials for instal- struction.
e[tend the wires, or use intermediate connection. lation. ■ In Australia, only technicians that possess the appro-
,QFRPSOHWHFRQQHFWLQJDQGVHFXULQJFRXOGFDXVH¿UH 7KHSUHVVXUHRI5LVWLPHVPRUHWKDQ51RWXVLQJ priate license issued by the Australian Refrigeration
■ Do not install the unit in a place where inÀammable DSSURSULDWHWRROVRUPDWHULDOVDQGLQFRPSOHWHLQVWDOODWLRQ Council (ARC) should install this product.
gas may leak. FRXOGFDXVHWKHSLSHVWREXUVWRULQMXU\
,IJDVOHDNVDQGDFFXPXODWHVLQWKHDUHDDURXQGWKHXQLW ■ When pumping down the refrigerant, stop the com-
LWFRXOGFDXVHDQH[SORVLRQ pressor before disconnecting the refrigerant pipes.
■ Do not use intermediate connection of the power ,IWKHUHIULJHUDQWSLSHVDUHGLVFRQQHFWHGZKLOHWKHFRP-
cord or the e[tension cord and do not connect many SUHVVRULVUXQQLQJDQGWKHVWRSYDOYHLVRSHQDLUFRXOGEH
devices to one AC outlet. GUDZQLQDQGWKHSUHVVXUHLQWKHUHIULJHUDWLRQF\FOHFRXOG
,WFRXOGFDXVHD¿UHRUDQHOHFWULFVKRFNGXHWRGHIHFWLYH EHFRPHDEQRUPDOO\KLJK7KLVFRXOGFDXVHWKHSLSHVWR
FRQWDFWGHIHFWLYHLQVXODWLRQH[FHHGLQJWKHSHUPLVVLEOH EXUVWRULQMXU\
FXUUHQWHWF
CAUTION &RXOGOHDGWRVHULRXVLQMXU\LQSDUWLFXODUHQYLURQPHQWVZKHQRSHUDWHGLQFRUUHFWO\
■ Install an earth leakage breaker depending on the ■ Do not touch the air inlet or the aluminum ¿ns of the ■ Do not operate the air conditioner during interior
installation place. outdoor unit. construction and ¿nishing work, or while wa[ing the
,IDQHDUWKOHDNDJHEUHDNHULVQRWLQVWDOOHGLWFRXOGFDXVH 7KLVFRXOGFDXVHLQMXU\ Àoor.
HOHFWULFVKRFN ■ Do not install the outdoor unit where small animals %HIRUHRSHUDWLQJWKHDLUFRQGLWLRQHUYHQWLODWHWKHURRPZHOO
■ Perform the drainage/piping work securely according may live. DIWHUVXFKZRUNLVSHUIRUPHG2WKHUZLVHLWPD\FDXVHYROD-
to the installation manual. ,IVPDOODQLPDOVHQWHUDQGWRXFKWKHHOHFWULFSDUWVLQVLGHWKH WLOHHOHPHQWVWRDGKHUHLQVLGHWKHDLUFRQGLWLRQHUUHVXOWLQJ
,IWKHUHLVGHIHFWLQWKHGUDLQDJHSLSLQJZRUNZDWHUFRXOG XQLWLWFRXOGFDXVHDPDOIXQFWLRQVPRNHHPLVVLRQRU¿UH LQZDWHUOHDNDJHRUVFDWWHULQJRIGHZ
GURSIURPWKHXQLWVRDNLQJDQGGDPDJLQJKRXVHKROGJRRGV $OVRDGYLVHXVHUWRNHHSWKHDUHDDURXQGWKHXQLWFOHDQ
1-2. SELECTING THE INSTALLATION LOCATION
INDOOR UNIT OUTDOOR UNIT
:KHUHLWLVQRWH[SRVHGWRVWURQJZLQG,IWKHRXWGRRUXQLWLVH[SRVHGWRDZLQGGXULQJ
WARNING GHIURVWLQJWKHGHIURVWLQJWLPHZLOOEHORQJHU
:KHUHDLUÀRZLVJRRGDQGGXVWOHVV
This unit should be installed in rooms which e[ceed the Àoor space
speci¿ed below. :KHUHUDLQRUGLUHFWVXQOLJKWFDQEHDYRLGHGDVPXFKDVSRVVLEOH
GN50: 1.7 m2 :KHUHQHLJKERXUVDUHQRWDQQR\HGE\RSHUDWLRQVRXQGRUKRWDLU
GN60: 2.5 m2 :KHUH ULJLG ZDOO RU VXSSRUW LV DYDLODEOH WR SUHYHQW WKH LQFUHDVH RI RSHUDWLRQ VRXQG RU
YLEUDWLRQ
:KHUHDLUÀRZLVQRWEORFNHG :KHUHWKHUHLVQRULVNRIFRPEXVWLEOHJDVOHDNDJH
:KHUHFRRODLUVSUHDGVRYHUWKHHQWLUHURRP :KHQLQVWDOOLQJWKHXQLWDWDKLJKOHYHOEHVXUHWRVHFXUHWKHXQLWOHJV
5LJLGZDOOZLWKRXWYLEUDWLRQ
:KHUHLWLVDWOHDVWPDZD\IURPWKHDQWHQQDRI79VHWRUUDGLR2SHUDWLRQRIWKHDLU
:KHUHLWLVQRWH[SRVHGWRGLUHFWVXQVKLQH'RQRWH[SRVHWRGLUHFWVXQVKLQHDOVRGXULQJ
WKHSHULRGIROORZLQJXQSDFNLQJWREHIRUHXVH FRQGLWLRQHUPD\LQWHUIHUHZLWKUDGLRRU79UHFHSWLRQLQDUHDVZKHUHUHFHSWLRQLVZHDN$Q
:KHUHHDVLO\GUDLQHG DPSOL¿HUPD\EHUHTXLUHGIRUWKHDIIHFWHGGHYLFH
$WDGLVWDQFHPRUPRUHDZD\IURP\RXU79DQGUDGLR2SHUDWLRQRIWKHDLUFRQGLWLRQHU ,QVWDOOWKHXQLWKRUL]RQWDOO\
PD\LQWHUIHUHZLWKUDGLRRU79UHFHSWLRQ$QDPSOL¿HUPD\EHUHTXLUHGIRUWKHDIIHFWHG 3OHDVHLQVWDOOLWLQDQDUHDQRWDIIHFWHGE\VQRZIDOORUEORZLQJVQRZ,QDUHDVZLWKKHDY\
GHYLFH VQRZSOHDVHLQVWDOODFDQRS\DSHGHVWDODQGRUVRPHEDIÀHERDUGV
,QDSODFHDVIDUDZD\DVSRVVLEOHIURPÀXRUHVFHQWDQGLQFDQGHVFHQWOLJKWV,QRUGHUWR
PDNHWKHLQIUDUHGUHPRWHFRQWUROFDQRSHUDWHWKHDLUFRQGLWLRQHUQRUPDOO\7KHKHDWIURP Note:
WKHOLJKWVPD\FDXVHGHIRUPDWLRQRUWKHXOWUDYLROHWPD\FDXVHGHWHULRUDWLRQ
,WLVDGYLVDEOHWRPDNHDSLSLQJORRSQHDURXWGRRUXQLWVRDVWRUHGXFHYLEUDWLRQWUDQVPLW-
:KHUHWKHDLU¿OWHUFDQEHUHPRYHGDQGUHSODFHGHDVLO\
:KHUHLWLVDZD\IURPWKHRWKHUKHDWRUVWHDPVRXUFH WHGIURPWKHUH
REMOTE CONTROLLER
:KHUHLWLVHDV\WRRSHUDWHDQGHDVLO\YLVLEOH Note:
:KHUHFKLOGUHQFDQQRWWRXFKLW :KHQRSHUDWLQJWKHDLUFRQGLWLRQHULQORZRXWVLGHWHPSHUDWXUHEHVXUHWRIROORZWKHLQVWUXF-
6HOHFWDSRVLWLRQDERXWPDERYHWKHÀRRUDQGFKHFNWKDWVLJQDOVIURPWKHUHPRWH WLRQVGHVFULEHGEHORZ
FRQWUROOHUDUHVXUHO\UHFHLYHGE\WKHLQGRRUXQLWIURPWKDWSRVLWLRQµEHHS¶RUµEHHSEHHS¶
1HYHULQVWDOOWKHRXWGRRUXQLWLQDSODFHZKHUHLWVDLULQOHWRXWOHWVLGHPD\EHH[SRVHG
UHFHLYLQJWRQHVRXQGV$IWHUWKDWDWWDFKUHPRWHFRQWUROOHUKROGHUWRDSLOODURUZDOODQG GLUHFWO\WRZLQG
LQVWDOOZLUHOHVVUHPRWHFRQWUROOHU 7RSUHYHQWH[SRVXUHWRZLQGLQVWDOOWKHRXWGRRUXQLWZLWKLWVDLULQOHWVLGHIDFLQJWKHZDOO
7RSUHYHQWH[SRVXUHWRZLQGLWLVUHFRPPHQGHGWRLQVWDOODEDIÀHERDUGRQWKHDLURXWOHW
Note:
,QURRPVZKHUHLQYHUWHUW\SHÀXRUHVFHQWODPSVDUHXVHGWKHVLJQDOIURPWKHZLUHOHVVUHPRWH VLGHRIWKHRXWGRRUXQLW
FRQWUROOHUPD\QRWEHUHFHLYHG $YRLGWKHIROORZLQJSODFHVIRULQVWDOODWLRQZKHUHDLUFRQGLWLRQHUWURXEOHLVOLDEOHWRRFFXU
:KHUHÀDPPDEOHJDVFRXOGOHDN
:KHUHWKHUHLVPXFKPDFKLQHRLO
:KHUHRLOLVVSODVKHGRUZKHUHWKHDUHDLV¿OOHGZLWKRLO\VPRNHVXFKDVFRRNLQJDUHDV
DQGIDFWRULHVLQZKLFKWKHSURSHUWLHVRISODVWLFFRXOGEHFKDQJHGDQGGDPDJHG
6DOW\SODFHVVXFKDVWKHVHDVLGH
:KHUHVXO¿GHJDVLVJHQHUDWHGVXFKDVKRWVSULQJVHZDJHZDVWHZDWHU
:KHUHWKHUHLVKLJKIUHTXHQF\RUZLUHOHVVHTXLSPHQW
:KHUHWKHUHLVHPLVVLRQRIKLJKOHYHOVRI92&VLQFOXGLQJSKWKDODWHFRPSRXQGVIRU-
PDOGHK\GHHWFZKLFKPD\FDXVHFKHPLFDOFUDFNLQJ
7KHDSSOLDQFHVKDOOEHVWRUHGVRDVWRSUHYHQWPHFKDQLFDOGDPDJHIURPRFFXUULQJ
1-3. SPECIFICATIONS
3LSHVL]H
0RGHO 3RZHUVXSSO\
:LUHVSHFL¿FDWLRQV
WKLFNQHVV
0D[LPXPDPRXQWRI
,QGRRURXWGRRU UHIULJHUDQWFKDUJH
,QGRRUXQLW 2XWGRRUXQLW 5DWHGYROWDJH )UHTXHQF\ %UHDNHUFDSDFLW\ 3RZHUVXSSO\
*DV/LTXLG
FRQQHFWLQJZLUH
FRUH
06<*19) 08<*19) $ J
PP FRUH ¡PP
9 +]
FRUH PP PP
06<*19) 08<*19) $ J
PP
&RQQHFWWRWKHSRZHUVZLWFKZKLFKKDVDJDSRIPPRUPRUHZKHQRSHQWRLQWHUUXSWWKH
3LSHOHQJWKDQGKHLJKWGLIIHUHQFH
VRXUFHSRZHUSKDVH:KHQWKHSRZHUVZLWFKLVVKXWRIILWPXVWLQWHUUXSWDOOSKDVHV
0D[SLSHOHQJWK P
8VHZLUHVLQFRQIRUPLW\ZLWKGHVLJQ,(&
1HYHUXVHSLSHVZLWKWKLFNQHVVOHVVWKDQVSHFL¿HG7KHSUHVVXUHUHVLVWDQFHZLOOEHLQVXI- 0D[KHLJKWGLIIHUHQFH P
¿FLHQW 0D[QXPEHURIEHQGV
8VHDFRSSHUSLSHRUDFRSSHUDOOR\VHDPOHVVSLSH 5HIULJHUDQWDGMXVWPHQW$
JP
%HFDUHIXOQRWWRFUXVKRUEHQGWKHSLSHGXULQJSLSHEHQGLQJ ,QVXODWLRQWKLFNQHVV
PP
5HIULJHUDQWSLSHEHQGLQJUDGLXVPXVWEHPPRUPRUH
,ISLSHOHQJWKH[FHHGVPDGGLWLRQDOUHIULJHUDQW5FKDUJHLVUHTXLUHG
1RDGGLWLRQDOFKDUJHLVUHTXLUHGIRUSLSHOHQJWKOHVVWKDQP
$GGLWLRQDOUHIULJHUDQW $îSLSHOHQJWKP
,QVXODWLRQPDWHULDO+HDWUHVLVWLQJIRDPSODVWLFVSHFL¿FJUDYLW\
%HVXUHWRXVHWKHLQVXODWLRQRIVSHFL¿HGWKLFNQHVV([FHVVLYHWKLFNQHVVPD\FDXVHLQFRU-
UHFWLQVWDOODWLRQRIWKHLQGRRUXQLWDQGLQVXI¿FLHQWWKLFNQHVVPD\FDXVHGHZGULSSDJH
1-4. INSTALLATION DIAGRAM
ACCESSORIES PARTS TO BE PROVIDED AT YOUR SITE
&KHFNWKHIROORZLQJSDUWVEHIRUHLQVWDOODWLRQ
,QGRRUXQLW!
,QVWDOODWLRQSODWH ,QGRRURXWGRRUXQLWFRQQHFWLQJZLUH
Note:
$
3ODFHLQGRRURXWGRRUXQLWFRQQHFWLQJZLUH$
,QVWDOODWLRQSODWH¿[LQJVFUHZ % ([WHQVLRQSLSH DQGSRZHUVXSSO\FRUG.DWOHDVWPDZD\
îPP & :DOOKROHVOHHYH IURPWKH79DQWHQQDZLUH
:LUHOHVVUHPRWHFRQWUROOHU ' :DOOKROHFRYHU
)HOWWDSH ( 3LSH¿[LQJEDQG WR
)RUOHIWRUOHIWUHDUSLSLQJ
) )L[LQJVFUHZIRU(îPP WR
5HPRWHFRQWUROOHUKROGHU
* 3LSLQJWDSH
)L[LQJVFUHZIRUîPP
+ 3XWW\
%ODFN
'UDLQKRVH
%DWWHU\$$$IRU
, RUVRIW39&KRVHPPLQQHU RU
GLDPHWHURUKDUG39&SLSH93
- 5HIULJHUDWLRQRLO
. 3RZHUVXSSO\FRUG
PRUHIRUOHIWDQGOHIW
PRUHPPRU
EDFNSLSLQJXVLQJ
PPRU
)L[LQJVFUHZ)
WARNING
7RDYRLGULVNRI¿UHÀDUHFRQQHFWLRQVKRXOGEHLQVWDOOHGRXWGRRUV
5HXVDEOHPHFKDQLFDOFRQQHFWRUVDQGÀDUHGMRLQWVDUHQRWDOORZHG
LQGRRUV
PWRPIURPWKH
ÀRRULVUHFRPPHQGHG
$IWHUWKHOHDNWHVWDSSO\LQVXODWLQJPDWHULDOWLJKWO\VR
(D) WKDWWKHUHLVQRJDS
(4) (C)
(G)
(E)
:KHQWKHSLSLQJLVWREHDWWDFKHGWRDZDOOFRQWDLQLQJPHWDOVWLQSODWHG
(3) (5) (F)
RUPHWDOQHWWLQJXVHDFKHPLFDOO\WUHDWHGZRRGHQSLHFHPPRUWKLFNHU
EHWZHHQWKHZDOODQGWKHSLSLQJRUZUDSWRWXUQVRILQVXODWLRQYLQ\OWDSH
(7)
(6) DURXQGWKHSLSLQJ
7RXVHH[LVWLQJSLSLQJSHUIRUP&22/RSHUDWLRQIRUPLQXWHVDQGSXPS
GRZQEHIRUHUHPRYLQJWKHROGDLUFRQGLWLRQHU5HPDNHÀDUHDFFRUGLQJWR
WKHGLPHQVLRQIRUQHZUHIULJHUDQW
FOHDU
PPRUPRUHZKHQIURQWDQG
VLGHVRIXQLWDUHFOHDU
WARNING
P 7RDYRLGULVNRI¿UHHPEHGRUSURWHFWWKHUHIULJHUDQWSLSLQJ
P H
PRU ([WHUQDOGDPDJHRQWKHUHIULJHUDQWSLSLQJFDQEHFDXVHRI¿UH
U
RUPPP R
RUH
Outdoor unit installation
PP
(K) (I) PP PP
$LULQOHW
PP
PP
PP
(A) (B)
$LULQOHW
PP UH
UPR
R RUPPP
RUH
$LURXWOHW
:KHQDQ\VLGHVRIOHIWULJKWDQG PPîPPVORW PP
UHDURIXQLWDUHFOHDU
$SSHDUDQFHRIWKHRXWGRRUXQLWPD\GLIIHUIURPVRPHPRGHOV
IMPORTANT NOTES
8QLWVVKRXOGEHLQVWDOOHGE\OLFHQVHGFRQWUDFWRUDFFRUGLQJWRORFDOFRGH
UHTXLUHPHQWV
7RFRPSO\ZLWKWKHUHTXLUHPHQWVRI$XVWUDOLDQVWDQGDUG$61=6
HOHFWULFDOLQVWDOODWLRQVZLULQJUXOHVWKHHOHFWULFDOZLULQJUHTXLUHGEHWZHHQ
WKHLQGRRUDQGRXWGRRUXQLWVPXVWEHLQVWDOOHGE\DOLFHQFHGHOHFWULFDO
FRQWUDFWRU.
&KHFNWKDWFDEOLQJZLOOQRWEHVXEMHFWWRZHDUFRUURVLRQH[FHVVLYHSUHV-
VXUHYLEUDWLRQVKDUSHGJHVRUDQ\RWKHUDGYHUVHHQYLURQPHQWDOHIIHFWV
7KHFKHFNVKDOODOVRWDNHLQWRDFFRXQWWKHHIIHFWVRIDJLQJRUFRQWLQXDO
YLEUDWLRQIURPVRXUFHVVXFKDVFRPSUHVVRUVRUIDQV
2. INDOOR UNIT INSTALLATION
2-1. FIXING OF INSTALLATION PLATE 2-4. PIPE FORMING AND DRAIN PIPING
)LQGDVWUXFWXUDOPDWHULDOVXFKDVDVWXGLQWKHZDOODQG¿[LQVWDOODWLRQSODWHKRUL- Pipe Forming )HOWWDSH
]RQWDOO\E\WLJKWHQLQJWKH¿[LQJVFUHZV¿UPO\ 3ODFHWKHGUDLQKRVHEHORZWKHUHIULJHUDQWSLSLQJ 3LSLQJWDSH*
7RSUHYHQWLQVWDOODWLRQSODWHIURPYLEUDWLQJEHVXUHWRLQVWDOOWKH¿[LQJVFUHZVLQWKH 0DNHVXUHWKDWWKHGUDLQKRVHLVQRWKHDYHGRUVQDNHG /LTXLGSLSH
KROHVLQGLFDWHGLQWKHLOOXVWUDWLRQ)RUDGGHGVXSSRUW¿[LQJVFUHZVPD\DOVREHLQVWDOOHG 'RQRWSXOOWKHKRVHZKHQDSSO\LQJWKHWDSH
*DVSLSH
LQRWKHUKROHV :KHQWKHGUDLQKRVHSDVVHVWKHURRPEHVXUHWRZUDSLQVXOD-
:KHQWKHNQRFNRXWLVUHPRYHGDSSO\YLQ\OWDSHWRWKHNQRFNRXWHGJHVWRSUHYHQWGDPDJ- WLRQPDWHULDOREWDLQDEOHDWDVWRUHDURXQGLW ,QGRRURXWGRRUXQLW
LQJWKHZLUHV FRQQHFWLQJZLUH$
:KHQEROWVUHFHVVHGLQWKHFRQFUHWHZDOODUHWREHXWLOL]HGVHFXUHLQVWDOODWLRQSODWH
XVLQJîāîRYDOKROHPPSLWFK Rear, right, or downward piping &XWRIILQFDVHRI
,IWKHUHFHVVHGEROWLVWRRORQJFKDQJHLWIRUDVKRUWHURQHDYDLODEOHLQWKHPDUNHW 3XW WKH UHIULJHUDQW SLSLQJ DQG WKH GUDLQ KRVH ULJKWSLSLQJ
WRJHWKHUWKHQ¿UPO\DSSO\SLSLQJWDSH*IURP
WKHHQG
2-2. WALL HOLE DRILLING ,QVHUWWKHSLSLQJDQGWKHGUDLQKRVHLQWRWKHZDOO &XWRIILQFDVHRI
'HWHUPLQHWKHZDOOKROHSRVLWLRQ GRZQZDUGSLSLQJ
:DOO KROHVOHHYH&DQGKRRNWKHXSSHUSDUWRIWKH
'ULOOD¡PPKROH7KHRXWGRRUVLGHVKRXOGEHWR LQGRRUXQLWRQWKHLQVWDOODWLRQSODWH
PPORZHUWKDQWKHLQGRRUVLGH ¡PP &KHFNLIWKHLQGRRUXQLWLVKRRNHGVHFXUHO\RQWKHLQVWDOODWLRQSODWHE\PRYLQJ
,QVHUWZDOOKROHVOHHYH& PP
WKHXQLWWROHIWDQGULJKW
7KUXVWWKHORZHUSDUWRIWKHLQGRRUXQLWLQWRWKHLQVWDOODWLRQSODWH
2XWGRRU
VLGH
Drain Piping
&HLOLQJ PPRUPRUH ,IWKHH[WHQVLRQGUDLQKRVHKDVWRSDVVWKURXJKDURRPEHVXUHWRZUDSLWZLWKFRPPHU-
PPRUPRUHIRUOHIWDQGOHIW FLDOO\VROGLQVXODWLRQ
EDFNSLSLQJXVLQJVSDFHU 7KHGUDLQKRVHVKRXOGSRLQWGRZQZDUGIRUHDV\GUDLQÀRZ)LJ
/HYHO
,QVWDOODWLRQSODWH ,IWKHGUDLQKRVHSURYLGHGZLWKWKHLQGRRUXQLWLVWRRVKRUWFRQQHFWLWZLWKGUDLQKRVH,
WKDWVKRXOGEHSURYLGHGDW\RXUVLWH)LJ
:KHQFRQQHFWLQJWKHGUDLQKRVHWRWKHKDUGYLQ\OFKORULGHSLSHEHVXUHWRLQVHUWLWVHFXUHO\
PPRU PPRU LQWRWKHSLSH)LJ
PRUH PRUH
PP 'UDLQKRVH
:DOO :DOO 'UDLQ
KRVH +DUGYLQ\OFKORULGH
FP SLSH,'PP
'RZQZDUG RUPRUH
)L[LQJ VORSH
VFUHZ
6RIWKRVH ,QVHUW
,'PP VHFXUHO\
7KHXQLRQMRLQWVRIWKHLQGRRU ,QVHUWWKH $OLJQWKHVFDOH &HQWHURI 'LIIHUHQW
XQLWDUHPPWRWKHOHIWRI VFDOH
ZLWKWKHOLQH
¡PPKROH GLDPHWHUMRLQW
WKHVHSXQFKPDUNV )LJ )LJ )LJ
6DPHIRUOHIWKROH
'RQRWPDNHGUDLQSLSLQJDVVKRZQEHORZ
%XUU &RSSHUSLSH
6SDUHUHDPHU
3LSHFXWWHU
&OXWFKW\SH :LQJQXWW\SH
)LJ )LJ
,QVLGHLVVKLQ-
6PRRWKDOO LQJZLWKRXWDQ\
DURXQG VFUDWFKHV
&RSSHUSLSH
'LH
(YHQOHQJWK
)ODUHQXW )LJ DOODURXQG )LJ
$PP 7LJKWHQLQJWRUTXH
3LSHGLDPHWHU 1XW &OXWFKW\SH :LQJQXW
PP PP WRROIRU5 &OXWFKW\SH W\SHWRRO 1P NJIFP
WRROIRU5
5$ IRU5
¡´ WR WR
WR
¡´ WR WR
WR WR
¡´ WR WR
WR
¡´ WR WR
4. PURGING PROCEDURES, LEAK TEST, AND TEST RUN
4-1. PURGING PROCEDURES AND LEAK TEST 4-2. TEST RUN
5HPRYHVHUYLFHSRUWFDSRIVWRSYDOYHRQWKHVLGHRIWKHRXWGRRUXQLWJDVSLSH7KHVWRS ,QVHUWSRZHUVXSSO\SOXJLQWRWKHSRZHURXWOHWDQGRUWXUQ
YDOYHVDUHIXOO\FORVHGDQGFRYHUHGLQFDSVLQLQLWLDOVWDWH RQWKHEUHDNHU
&RQQHFWJDXJHPDQLIROGYDOYHDQGYDFXXPSXPSWRVHUYLFHSRUWRIVWRSYDOYHRQWKH 3UHVVWKH(26:7HVWUXQZLOOEHSHUIRUPHGIRUPLQ-
JDVSLSHVLGHRIWKHRXWGRRUXQLW XWHV,IWKHXSSHUODPSRIWKHRSHUDWLRQLQGLFDWRUEOLQNVHYHU\
VHFRQGVLQVSHFWWKHLQGRRURXWGRRUXQLWFRQQHFWLQJZLUH
–03D &RPSRXQGSUHVVXUHJDXJH $IRUPLVZLULQJ$IWHUWKHWHVWUXQHPHUJHQF\PRGHVHW
WRWXUQV 6WRSYDOYHFDS IRU55$
–PP+J WHPSHUDWXUH&ZLOOVWDUW
7RUTXHWR 3UHVVXUHJDXJH
&ORVH 1P 7RVWRSRSHUDWLRQSUHVVWKH(26:VHYHUDOWLPHVXQWLO
6WRSYDOYH IRU55$
2SHQ WRNJIFP
IRU/,48,' DOO/('ODPSVWXUQRII5HIHUWRRSHUDWLQJLQVWUXFWLRQVIRU (PHUJHQF\
*DXJHPDQLIROGYDOYH RSHUDWLRQVZLWFK
IRU55$ GHWDLOV
(26:
+DQGOH +DQGOH+LJK
+H[DJRQDOZUHQFK /RZ
&KDUJHKRVH Checking the remote (infrared) signal reception
6WRSYDOYHIRU IRU55$ 3UHVVWKH2))21EXWWRQRQWKHUHPRWHFRQWUROOHUDQGFKHFNWKDWDQHOHFWURQLFVRXQG
*$6
LVKHDUGIURPWKHLQGRRUXQLW3UHVVWKH2))21EXWWRQDJDLQWRWXUQWKHDLUFRQGLWLRQHURII
6HUYLFHSRUWFDS
7RUTXHWR 2QFHWKHFRPSUHVVRUVWRSVWKHUHVWDUWSUHYHQWLYHGHYLFHRSHUDWHVVRWKHFRPSUHVVRU
$GDSWHUIRU
1PWR SUHYHQWLQJWKH
ZLOOQRWRSHUDWHIRUPLQXWHVWRSURWHFWWKHDLUFRQGLWLRQHU
NJIFP EDFNÀRZ 9DFXXPSXPSRUWKHYDFXXP
SXPSZLWKWKHIXQFWLRQWR
SUHYHQWWKHEDFNÀRZ 4-3. AUTO RESTART FUNCTION
7KLVSURGXFWLVHTXLSSHGZLWKDQDXWRUHVWDUWIXQFWLRQ:KHQWKHSRZHUVXSSO\LVVWRSSHG
GXULQJRSHUDWLRQVXFKDVGXULQJEODFNRXWVWKHIXQFWLRQDXWRPDWLFDOO\VWDUWVRSHUDWLRQLQ
:KHQ DWWDFKLQJ WKH FRQWURO YDOYH WKHSUHYLRXVVHWWLQJRQFHWKHSRZHUVXSSO\LVUHVXPHG5HIHUWRWKHRSHUDWLQJLQVWUXFWLRQV
3UHFDXWLRQVZKHQXVLQJWKHFRQWUROYDOYH
WRWKHVHUYLFHSRUWYDOYHFRUHPD\ IRUGHWDLOV
<R32>
GHIRUPRUORRVHQLIH[FHVVSUHVVXUH
LVDSSOLHG7KLVPD\FDXVHJDVOHDN
Caution:
:KHQDWWDFKLQJWKHFRQWUROYDOYHWR $IWHUWHVWUXQRUUHPRWHVLJQDOUHFHSWLRQFKHFNWXUQRIIWKHXQLWZLWKWKH(26:RU
6HUYLFH WKHVHUYLFHSRUWPDNHVXUHWKDWWKH
SRUW WKHUHPRWHFRQWUROOHUEHIRUHWXUQLQJRIIWKHSRZHUVXSSO\1RWGRLQJVRZLOOFDXVHWKH
$ YDOYHFRUHLVLQFORVHGSRVLWLRQDQG
WKHQ WLJKWHQ SDUW$ 'R QRW WLJKWHQ XQLWWRVWDUWRSHUDWLRQDXWRPDWLFDOO\ZKHQSRZHUVXSSO\LVUHVXPHG
2SHQ %RG\ SDUW$RUWXUQWKHERG\ZKHQYDOYH To the user
0DNHVXUHWR &ORVH &KDUJH
UHSODFHWKHFDSDIWHU &RQWURO FRUHLVLQRSHQSRVLWLRQ $IWHULQVWDOOLQJWKHXQLWPDNHVXUHWRH[SODLQWKHXVHUDERXWDXWRUHVWDUWIXQFWLRQ
YDOYH KRVH
WKHRSHUDWLRQ ,I DXWR UHVWDUW IXQFWLRQ LV XQQHFHVVDU\ LW FDQ EH GHDFWLYDWHG &RQVXOW WKH VHUYLFH
UHSUHVHQWDWLYHWRGHDFWLYDWHWKHIXQFWLRQ5HIHUWRWKHVHUYLFHPDQXDOIRUGHWDLOV
5XQWKHYDFXXPSXPS9DFXXPL]HXQWLOPLFURQVLVDFKLHYHG
&KHFNWKHYDFXXPZLWKJDXJHPDQLIROGYDOYHWKHQFORVHJDXJHPDQLIROGYDOYHDQGVWRS
WKHYDFXXPSXPS 4-4. EXPLANATION TO THE USER
/HDYHDVLWLVIRURQHRUWZRPLQXWHV0DNHVXUHSRLQWHUJDXJHPDQLIROGYDOYHUHPDLQV 8VLQJWKH23(5$7,1*,16758&7,216H[SODLQWRWKHXVHUKRZWRXVHWKHDLUFRQGL-
LQWKHVDPHSRVLWLRQ&RQ¿UPWKDWSUHVVXUHJDXJHVKRZV±03D>*DXJH@± WLRQHUKRZWRXVHWKHUHPRWHFRQWUROOHUKRZWRUHPRYHWKHDLU¿OWHUVKRZWRUHPRYHRU
PP+J SXWWKHUHPRWHFRQWUROOHULQWKHUHPRWHFRQWUROOHUKROGHUKRZWRFOHDQSUHFDXWLRQVIRU
5HPRYHJDXJHPDQLIROGYDOYHTXLFNO\IURPVHUYLFHSRUWRIVWRSYDOYH RSHUDWLRQHWF
5HFRPPHQGWKHXVHUWRUHDGWKH23(5$7,1*,16758&7,216FDUHIXOO\
WARNING
To avoid risk of ¿re, make sure that there are no Àammable ha]ards or ignition
risks before opening the stop valves.
$IWHUUHIULJHUDQWSLSHVDUHFRQQHFWHGDQGHYDFXDWHGIXOO\RSHQDOOVWRSYDOYHVRQERWK
VLGHVRIJDVSLSHDQGOLTXLGSLSH2SHUDWLQJZLWKRXWIXOO\RSHQLQJORZHUVWKHSHUIRUPDQFH
DQGWKLVFDXVHVWURXEOH
5HIHUWRDQGFKDUJHWKHSUHVFULEHGDPRXQWRIUHIULJHUDQWLIQHHGHG%HVXUHWRFKDUJH
VORZO\ZLWKOLTXLGUHIULJHUDQW2WKHUZLVHFRPSRVLWLRQRIWKHUHIULJHUDQWLQWKHV\VWHPPD\
EHFKDQJHGDQGDIIHFWSHUIRUPDQFHRIWKHDLUFRQGLWLRQHU
7LJKWHQFDSRIVHUYLFHSRUWWRREWDLQWKHLQLWLDOVWDWXV
/HDNWHVW
5. RELOCATION AND MAINTENANCE
5-1. REMOVING AND INSTALLING THE PANEL ASSEMBLY 5-3. PUMPING DOWN
:KHQ UHORFDWLQJ RU GLVSRVLQJ RI WKH DLU FRQGLWLRQHU SXPS GRZQ WKH V\VWHP IROORZLQJ WKH
Removal procedure SURFHGXUHEHORZVRWKDWQRUHIULJHUDQWLVUHOHDVHGLQWRWKHDWPRVSKHUH
2SHQWKHIURQWSDQHO &RQQHFWWKHJDXJHPDQLIROGYDOYHWRWKHVHUYLFHSRUWRIWKHVWRSYDOYHRQWKHJDVSLSHVLGH
5HPRYHWKHVFUHZVZKLFK¿[WKHSDQHODVVHPEO\ 1
RIWKHRXWGRRUXQLW
&ORVHWKHIURQWSDQHO 3 )XOO\FORVHWKHVWRSYDOYHRQWKHOLTXLGSLSHVLGHRIWKHRXWGRRUXQLW
5HPRYHWKHSDQHODVVHPEO\%HVXUHWRUHPRYH 4
LWVERWWRPHQG¿UVW &ORVHWKHVWRSYDOYHRQWKHJDVSLSHVLGHRIWKHRXWGRRUXQLWDOPRVWFRPSOHWHO\VRWKDWLW
4 2 2 2
FDQEHHDVLO\FORVHGIXOO\ZKHQWKHSUHVVXUHJDXJHVKRZV03D>*DXJH@NJIFP
6WDUWWKHHPHUJHQF\&22/RSHUDWLRQ
7RVWDUWWKHHPHUJHQF\RSHUDWLRQLQ&22/PRGHGLVFRQQHFWWKHSRZHUVXSSO\SOXJDQG
Installation procedure RUWXUQRIIWKHEUHDNHU$IWHUVHFRQGVFRQQHFWWKHSRZHUVXSSO\SOXJDQGRUWXUQRQ
,QVWDOO WKH SDQHO DVVHPEO\ IROORZLQJ WKH UHPRYDO WKHEUHDNHUDQGWKHQSUHVVWKH(26:RQFH7KHHPHUJHQF\&22/RSHUDWLRQFDQEH
SURFHGXUHLQUHYHUVH SHUIRUPHGFRQWLQXRXVO\IRUXSWRPLQXWHV
%HVXUHWRSUHVVWKHSRVLWLRQVDVLQGLFDWHGE\WKH
)XOO\FORVHWKHVWRSYDOYHRQWKHJDVSLSHVLGHRIWKHRXWGRRUXQLWZKHQWKHSUHVVXUHJDXJH
DUURZVLQRUGHUWRDWWDFKWKHDVVHPEO\FRPSOHWHO\
WRWKHXQLW VKRZVWR03D>*DXJH@DSSUR[WRNJIFP
6WRSWKHHPHUJHQF\&22/RSHUDWLRQ
3UHVVWKH(26:VHYHUDOWLPHVXQWLODOO/('ODPSVWXUQRII5HIHUWRRSHUDWLQJLQVWUXFWLRQV
IRUGHWDLOV
5-2. REMOVING THE INDOOR UNIT
WARNING
5HPRYHWKHERWWRPRIWKHLQGRRUXQLWIURPWKHLQVWDO-
ODWLRQSODWH When pumping down the refrigerant, stop the compressor before disconnecting the
:KHQUHOHDVLQJWKHFRUQHUSDUWUHOHDVHERWKOHIWDQG refrigerant pipes. The compressor may burst if air etc. get into it.
ULJKWERWWRPFRUQHUSDUWRILQGRRUXQLWDQGSXOOLWGRZQ-
ZDUGDQGIRUZDUGDVVKRZQLQWKH¿JXUHRQWKHULJKW
+($'2)),&(72.<2%8,/',1*0$58128&+,&+,<2'$.8
72.<2-$3$1