You are on page 1of 2

9RLFH3RUWŒ0RGXODU ,QVHUWLQJWKH0$; &RQQHFWLQJWKHJURXQGLQJZLUH

$FFHVV 0$; 
,QVWDOODWLRQ,QVWUXFWLRQV
:DOO0RXQW
$569' 5HOHDVH  6WDQGDUG 
6HSWHPEHU 

DANGER
Risk of disrupting net-
work power and personal
injury  6HFXUHWKH0$;LQWKHPRXQWLQJ
When using composite EUDFNHWE\DWWDFKLQJWKHVFUHZV
power, disconnect power at WKURXJKWKHWRSRIWKHPRGXOH7RUTXH
ground lug dome ground
the tap before performing VFUHZVWRLQOEVPD[LPXP assembly nut wire
these tasks. 6HFXULQJWKH0$;

 'ULOOKROHVIRUWKHPRXQWLQJEUDFNHW  5HPRYHGRPHQXWDQGSOXJIURP5)
LQLQGLDPHWHUDQGLQGHHS ZLUHFDEOHILWWLQJLQVHUW5)FRD[DQG
$WWDFKEUDFNHWWRZDOOXVLQJVHOI VHFXUHWR)FRQQHFWRUDVVKRZQ
WDSSLQJVFUHZV 7LJKWHQGRPHQXWRQWRFDEOHILWWLQJ
QXWWRHQYLURQPHQWDOO\VHDO5)FRD[
$WWDFKLQJWKHPRXQWLQJEUDFNHW
&RQQHFWLQJWKH5)FDEOH

 5HPRYHGRPHQXWDQGSOXJIURP
JURXQGLQJZLUHFDEOHILWWLQJ,QVHUW
JURXQGZLUHDQGVHFXUHLQWRJURXQG
OXJDVVHPEO\7LJKWHQGRPHQXWRQWR
FDEOHILWWLQJWRHQYLURQPHQWDOO\VHDO
WKHJURXQGZLUH
 ,QVWDOOWKH0$;E\LQVHUWLQJWKH
F-connector
ERWWRPKRRNVRIWKHXQLWLQWRWKH
EUDFNHWJURRYHV5RWDWHWKH0$;
XQWLOLWLVIOXVKZLWKWKHEUDFNHW dome nut RF cable
 5HPRYHGRPHQXWDQGSOXJIURPSRZHU  7KH0$;LVVKLSSHGZLWKDOOWHOHPH  &ORVHWKHFRYHUDQGVHFXUHZLWKD
ZLUHFDEOHILWWLQJDQGLQVHUWSRZHUZLUH WU\SRLQWVJURXQGHGXVLQJDGDLV\ LQVRFNHWRUIODWEODGHVFUHZ
5HPRYHWKHQXWIURPWKHSURWHFWRU FKDLQWHFKQLTXH GULYHU,QVWDOODVHFXULW\VFUHZLI
FRYHUDWWDFKSRZHUZLUHVEHWZHHQWKH GHVLUHG
WRSWZRZDVKHUVDQGUHSODFHWKHFRYHU Table 1: Telemetry status
6HFXULQJWKHFRYHUVFUHZV
7LJKWHQGRPHQXWRQWRFDEOHILWWLQJWR
HQYLURQPHQWDOO\VHDOWKHSRZHUZLUH Telemetry
Telemetry Input
1RWH3RODULW\RISRZHUZLUHVLVQRWFULW Points
LFDOIRUFRQQHFWLRQWRVWDWLRQSURWHFWRU Open Grounded
&RQQHFWLQJWKHSRZHUFDEOH Battery Battery AC
security
Door Open Closed screw

GTP1 User defined

GTP2 User defined standard


lock

5HIHUWRWKH0RGXODU$FFHVV 0$; 
,QVWDOODWLRQ*XLGH$569'IRU
IXUWKHUWHOHPHWU\LQIRUPDWLRQ
7HOHPHWU\SRLQWV
Dome Cover GTP2
Nut Nut
 5HPRYHGRPHQXWDQGSOXJIURP9) &RUQHUVWRQHŠ9RLFH
signal ground
FDEOHILWWLQJ6WULSDQGLQVHUW9)FDEOH door switch
9RLFH3RUW0RGXODU$FFHVV 0$; 
LQVXODWLRQDOORZLQJDGHTXDWHVHUYLFH
,QVWDOODWLRQ6KHHW :DOO0RXQW
ORRSIRUWZLVWHGSDLUZLUHV2SHQ9)FRQ
© 2001 ARRIS. All rights reserved.
QHFWRUZLWKWRRO&RQQHFW7LSDQG5LQJ
All information contained in this document is subject to
SDLUV&ORVHWRSRIWKH9)FRQQHFWRU5H
change without notice. Arris Interactive reserves the right to
DWWDFKGRPHQXWWRHQYLURQPHQWDOO\VHDO make changes to equipment design or program compo-
WKH9)FDEOH nents, as progress in engineering, manufacturing methods,
&RQQHFWLQJWKH9)FDEOH or other circumstances may warrant.
Cornerstone is a registered trademark of ARRIS Licensing
service Company. Voice Port is a trademark of ARRIS Licensing
loop Company. All other trademarks are the property of their
switch respective holders.
twisted battery Document number: ARSVD00416
pair GTP1
Release 8.1 Standard 1.0
September 2001
VF cable
fitting  7RGLVDEOHWKHGRRUVZLWFKUHPRYHWKH
VZLWFKZLUHVIURPWKHWHOHPHWU\SRLQWV
dome nut DQGSODFHDMXPSHUEHWZHHQWKH
VF cable VZLWFKDQGJURXQGSRLQWV