You are on page 1of 384

Pioneering for You

Catalogue Water Management 2014/2015

Drainage and Sewage –


Wastewater Transport and Dewatering

6XEPHUVLEOHSXPSVD[LDOSXPSVDQGDFFHVVRULHV RUGHUVSHFLÞFSURGXFWLRQ
´&RPLQJXSZLWKWKH
EHVWVROXWLRQLQFORVH
SDUWQHUVKLS
WKDW·VZKDW,FDOO
3LRQHHULQJIRU<RXµ
'DQLHO%XVXLRF,QWHUQDWLRQDO3URMHFWV&RRUGLQDWRU*URXS
&RPSHWHQFH7HDP:,/26(+RI*HUPDQ\

$W:LORZHNQRZDERXW\RXUORFDOFKDOOHQJHVLQZDWHUPDQDJHPHQW7KDW·VZK\ZHSURYLGH
DQHIÀFLHQWQHWZRUNRIVXEVLGLDULHVUHSUHVHQWDWLYHVDQGH[SHUWVZKRGHYHORSFXVWRPL]HG
VROXWLRQVRQWKHVSRW7KHVHSURIHVVLRQDOWHDPVLQYHVWDOOWKHLUSDVVLRQDQGNQRZKRZPDNLQJ
\RXVXFFHVVIXOLQ\RXUPDUNHW+RZFDQZHVXSSRUW\RXLQ\RXUORFDOEXVLQHVV"

ZZZZLORFRP

:LOR(08)$ :LOR(080HJDSURS :LOR6&3 :LOR(08.0


Contents

General notes and abbreviations 8

Wastewater transport 12

Submersible pumps for untreated sewage

Wastewater transport
Submersible pumps for sewage

Dewatering 304

Axial submersible pumps

Dewatering
Industrial processes 322

Submersible pumps in stainless steel casting

Industrial processes
Accessories 337

Mechanical accessories
Electrical accessories

Accessories

Consulting guide 352


Consulting guide

Wilo water management catalogue – 50 Hz – Drainage and sewage - Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 3
Drainage and sewage – Wastewater transport and dewatering
Contents

Wastewater transport

Submersible pumps for untreated sewage Series overview 12


Wilo-EMU FA SOLID 14

Submersible pumps for sewage Series overview 12


Wilo-Rexa PRO 37
Wilo-EMU FA 08...15 64
Wilo-EMU FA 20...25 207
Wilo-EMU FA 30...60 254

Dewatering

Axial submersible pumps Series overview 304


Wilo-EMU KPR 340 305
Wilo-EMU KPR 500 313
Wilo-EMU KPR 760 319

Industrial processes

Submersible pumps in stainless steel casting Series overview 322


Wilo-EMU FA 05.23 RFW 323
Wilo-EMU FA 05.32 RFE 328
Wilo-EMU FA 08.34 RFE 334

4 Wilo water management catalogue – 50 Hz – Drainage and sewage - Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Drainage and sewage – Wastewater transport and dewatering
Contents

Accessories

Mechanical accessories Set of chains 337

Wastewater transport
Suspension units 337
Coatings 338

Electrical accessories Switchgears 339


Level control 341
Control and relay 342
Switch cabinets 342

Consulting guide

Basic hydraulic principles 352


Pressure losses 354

Dewatering
Installation types 357
Pumped fluids and impeller shapes 359
Basic electric principles 362
Motors 364
Operating modes 367
Level measuring systems 369
Explosion protection 372
Materials 374

Industrial processes
Ceram coating 376

Accessories

Wilo water management catalogue – 50 Hz – Drainage and sewage - Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 5
Programme overview and fields of applications

Catalogue Water Supply

Glanded in-line pumps


Glanded monobloc pumps
Glanded norm pumps
Water Supply / Heating, Air-conditioning, Cooling Axially split case pumps
Condensate lifting units
High-pressure multistage centrifugal pumps
Pumps for fire extinguishing and sprinkler systems
Single-pump systems
Boosting
Multi-pump systems
Submersible pumps
Raw Water Intake Polder pumps (Bottom intake pumps)
Vertical turbine pumps

Catalogue Drainage and Sewage

Sewage lifting unit


Pumps stations
Wastewater Collection and Transport
Submersible sewage pumps with macerator
Solids separation systems (EMUport)
Submersible drainage pumps
Wastewater Transport and Dewatering
Self-priming drainage pumps
(Stock pumps)
Submersible sewage pumps

Wastewater Transport and Dewatering Submersible sewage pumps


(Order-specific production) Axial submersible pumps (pipe sump pumps)
Submersible mixer
Solids diffuser
Ventilation systems
Wastewater Treatment Submersible mixers for special and industrial applications (MUD mixers)
Recirculation pumps
Axial submersible pumps (pipe sump pumps)
Jet cleaner

Three other catalogues are available for building services applications.

Key: Fields of application:


• Applicable
- Not applicable Heating Rainwater utilisation
1)Local prescriptions and directives must be observed
Secondary hot water Water distribution/boosting

Air-conditioning Fire fighting1)

Cooling/Air-conditioning Clean water treatment

6 Wilo water management catalogue – 50 Hz – Drainage and sewage - Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Programme overview and fields of applications

Main field of application

• – • • – – – – – – – – – – – •

Trockenläuferpumpen
– – • • – – – – – – – – – – – •
• – • • – • • 1) • • – • – – – – •
– – • • – • – – – – – – – – – •
• – • • – – – – – – – – – – – –
– – – – – • – – – – • – – – – –
– – – – – – • 1) – – – – – – – – –
– – – – – • – – – – – – – – – –
– – – – – • • 1) – – – – – – – – –
• – – – • • – • • • • • – – – •
– – – – – • – • • • – – – – • •
– – – – – – – – • – • – – – – •

Blockpumpen
– – – – – – – – – – – – • – – –
– – – – – – – – – – – – • – – –
– – – – – – – – – – – – • – – –
– – – – – – – – – – – – • – – –
– – – – – – – – – – – – – – • •
– – – – – • – – – – • – – – • –
– – – – – – – – – – • • • • • •

Normpumpen
– – – – – – – – – – – • • • • •
– – – – – – – – • – – • – • • –
– – – – – – – – – – – • – • – –
– – – – – – – – – – – – – • – •
– – – – – – – – – – – – – • – –
– – – – – – – – – – – • – – – •
– – – – – – – – – – – • – • – –

Pumpen mit axial geteiltem


– – – – – – – – • – • • – • • –
– – – – – – – – – – – – – • – –

Gehäuse

Fields of application:
Mehrstufige Hochdruck-

Raw water intake Wastewater collection and transport


Kreiselpumpen

Desalination Wastewater treatment

Professional irrigation/agriculture Dewatering (incl. Flood Control)


Energy/Leisure/Service
Special applications Industrial process

Wilo water management catalogue – 50 Hz – Drainage and sewage - Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 7
General notes and abbreviations

Abbreviation Meaning Abbreviation Meaning


1~ 1-phase current Number of poles of electric motors:

3~ 3-phase current 4-pole motor = approx. 1450 rpm at 50 Hz
-A Float switch attached Number of poles of electric motors:

6-pole motor = approx. 950 rpm at 50 Hz
D Direct activation
DI Leakage detection
Di Inside diameter
Di min. Minimum inside diameter
DM Three-phase motor, 3~
DN Nominal diameter of the flange connection
EBM Individual run signal
EM Single-phase motor, 1~
ESM Individual fault signal
GRD/GLRD Mechanical seal
F Thrust in newtons (N) (for submersible mixers)
H, Hmax Delivery head
HA Suction head; inlet floor to ground level
HB Installation depth to inlet floor
HN Site altitude above MSL (mean sea level)
HG Groundwater level to MSL (mean sea level)
IA Starting current
IN Nominal current; current at P2
Inst. Installation: H = horizontal, V = vertical
Supply availability (L = stock article, C = available in
@ 2 weeks, K = available in 4 weeks, A = available on
request)
Power consumption (power supplied from the net-
P1
work)
P1.1 Power consumption at the duty point
P2 (PN) Nominal motor power
Pressure class in bar
PN
(e.g. PN10 = suitable up to 10 bar)
Positive temperature coefficient
PTC
(PTC thermistor sensor)
Platinum temperature sensor with a resistance value
PT 100
of 100 ũ at 0 °C
Q (=Ǵ) Volume flow
-S Float switch attached
SBM Run signal or collective run signal
SSM Fault signal or collective fault signal
Thermal winding contacts (in motor for monitoring
WSK the winding temperature, full motor protection
through additional tripping unit)
Y/ŕ Star-delta switching
Operating mode of double pumps:
;
Individual operation of the respective duty pump
Operating mode of double pumps:
<
Parallel operation of both pumps
Number of poles of electric motors:

2-pole motor = approx. 2900 rpm at 50 Hz

8 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
General notes and abbreviations

Material Meaning AISI Material Meaning AISI


1.0570 Steel S355J2G3 A106 Cast iron with spheroidal graphite, also
1.4021 Chromium steel X20Cr13 420 referred to as spheroidal cast iron. The
use of spheroidal cast iron in domestic
1.4057 Chromium steel X17CrNi16-2 431 EN-GJS water systems is governed by the
1.4112 Chromium steel X90CrMoV18 440B Drinking Water Directive 98/83/EC and
1.4122 Chromium steel X39CrMo17-1 applicable recognised technical rules
and standards!
1.4301 Chromium-nickel steel X5CrNi18-10 304
G-Al Si12 Die-cast aluminium
1.4305 Chromium-nickel steel X8CrNiS18-9 303
GfK Fibreglass plastic
1.4306 Chromium-nickel steel X2CrNi19-11 304L
GG See EN-GJL
1.4308 Chromium-nickel steel GX5CrNi19-10 304 CF8
GGG See EN-GJS
Chromium-nickel-molybdenum steel
1.4401 316 Inox Stainless steel
X5CrNiMo17-12-2
Chromium-nickel-molybdenum steel ABS Acrylic butadiene styrene
1.4404 316L
X2CrNiMo17-12-2 PA 30GF See Composite
Chromium-nickel-molybdenum steel PE-HD High-density polyethylene
1.4408 316
GX5CrNiMo19-11-2 Polypropylene, reinforced with
PP-GF30
Chromium-nickel-molybdenum steel 30 % fibreglass
1.4460 329
X3CrNiMoN 27-5-2 PUR Polyurethane
Chromium-nickel-molybdenum steel 329 SiC Silicon carbide
1.4462
X2CrNiMoN22-5-3 (2205)
St Steel
Chromium-nickel-molybdenum steel
1.4470 329 St.vz. Galvanised steel
GX2CrNiMoN22-5-3
Chromium-nickel-molybdenum steel V2A Material group, e.g. 1.4301, 1.4306 304
1.4517 with copper addition V4A Material group, e.g. 1.4404, 1.4571 316
GX2CrNiMoCuN25-6-3-3
1.4528 Blade steel X105CrCoMo182 440B+Co Wear and tear
Chromium-nickel steel with titanium Pumps or parts of pumps are subject to wear in accordance with the
1.4541 321
addition X6CrNiTi18-10 current technical standards (DIN 31051/DIN-EN 13306). This wear
Chromium-nickel steel with copper may vary depending on the operating parameters (temperature,
1.4542 and niobium additions 630 pressure, speed, water conditions) and the installation/usage situa-
X5CrNiCuNb16-4 tion and may result in the failure of the above products/components,
including their electrical/electronic circuits, at different times.
Chromium-nickel steel with titanium Wear or wearing parts are all components subject to rotary or dynam-
1.4571 316Ti
addition X6CrNiMoTi17-12-2 ic stress, including electronic components to which voltage is ap-
Chromium-nickel-molybdenum steel plied, including in particular:
316 /
1.4581 with niobium addition
316Nb • Gaskets (including mechanical seals), seal rings.
GX5CrNiMoNb19-11-2
• Stuffing boxes.
Chilled cast iron material for use in
Abrasite • Bearings and shafts.
strongly abrasive fluids
• Impellers and pump components.
Al Light metal material (aluminium) • Thrust rings and wear rings.
Al-oxide Aluminium oxide • Wear rings / wear plates.
• Macerators.
C Carbon
• Condensers.
Coating with very high adhesive • Relays/contactors/switches.
Ceram strength for long-lasting corrosion • Electronic circuits, semiconductor components etc.
protection
Composite High-strength plastic material Pumps and continuous-flow machines (such as submersible mixers
and recirculation pumps) and their coated components (cataphoretic,
Cr Chromium
2K or Ceram coating) are subject to constant wear due to the abrasive
Cast iron with lamellar graphite, also content of the fluids. For this reason the coating of these units is also
referred to as grey cast iron. The use of counted as a wearing part!
grey cast iron in domestic water sys-
EN-GJL
tems is governed by the Drinking Water We do not accept any liability for faults or defects arising from natu-
Directive 98/83/EC and applicable rec- ral wear and tear.
ognised technical rules and standards!
EN-GJL 200 Grey cast iron GG20 Wilo – General Terms of Delivery and Service
EN-GJL 250 Grey cast iron GG25 The latest version of our General Terms of Delivery and Service can be
found on the Internet at
EN-GJS-500-7 Spheroidal cast iron GGG50 www.wilo.com

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 9
General notes
Information for the pump curve graph

Wilo-EMU FA (example)

Pump curves, Wilo-EMU FA 20.78D - 50 Hz - 950 rpm Hydraulic type, rated frequency, rated speed
Closed multi-channel impeller - free ball passage: 76 mm Impeller shape, free ball passage

H/ m

16

30%
Delivery head 40%
14 50%
in meters. 60%
64%
68% H/Q pump curve in
12 70%
72% accordance with
74% ISO 9906, Appendix A

10

8
70%
68% Ø 320
6
Ø 310
64% Ø 300
4 Ø 290
Ø 280
Hydraulic Ø 270 Impeller diameter
efficiency in %. in mm.
2

0
0 100 200 300 400 500 Q/ m³/h Flow rate in m³/h.

0 20 40 60 80 100 120 140 Q/ l/s

Required P2 / kW
shaft power Ø 320
in kW
12 Ø 310
Ø 300
8 Ø 290
Ø 280
Ø 270
4
Limit range
(Operation only on Pump power curve
request) 0 (required shaft power)
0 100 200 300 400 500 Q/ m³/h

0 20 40 60 80 100 120 140 Q/ l/s Flow rate in l/s.

10 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
General notes

Equipment/function
Wilo-EMU Wilo-Rexa Wilo-EMU Wilo-EMU Wilo-EMU Wilo-EMU Wilo-EMU
FA…T PRO FA 08... - FA 20... - FA 30... - KPR FA...RF
15... 25... 60...
Design
Submersible • • • • • • •
Vortex impeller – • • – – – •
Single-channel impeller – – • • – – •
Two-channel impeller – – • • • – –
Three-/four-channel impeller – – • • • – –
SOLID impeller, closed • – – – – – –
Sealing chamber • • • • • • •
Leakage chamber • - • • • - -
Sealing for mechanical seal on motor side • • • • • • •
Sealing for rotary shaft seal on motor side • – • • • – –
Sealing for mechanical seal on fluid side • • • • • • •
Single-phase AC motor – • – – – – –
Three-phase motor • • • • • • •
Direct activation • • • • • • •
Star-delta activation • – • • • • •
FC operation • • • • • • •
Dry motor • • • • • • •
Motor with oil cooling • - • • • - -
Dry motor with closed-circuit cooling • - • • • - -
Sheath current cooling – – – – – – –
Application
Wet well installation, stationary • • • • • • •
Wet well installation, portable • • • • – – •
Dry well installation, stationary • • • • • – –
Dry well installation, portable • – • • – – –
Equipment/function
Motor leakage monitoring • • • • • • •
Sealing chamber monitoring ǽ ǽ ǽ ǽ ǽ ǽ ǽ
Leakage chamber monitoring • - • • • - -
Motor temperature monitoring, bimetal ǽ • ǽ ǽ ǽ ǽ •
Motor temperature monitoring, PTC ǽ ǽ ǽ ǽ ǽ ǽ ǽ
Explosion protection ǽ • ǽ ǽ ǽ ǽ ǽ
Float switch – – – – – – –
Capacitor box for 1~230 V – • – – – – –
Ready-to-plug – ǽ – – – – –
• = available, - = not available; ǽ = optional

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 11
Wastewater transport

Series overview
Series Wilo-EMU FA…T Wilo-Rexa PRO

Product photo
H/m

Wilo-EMU FA...T Wilo-Rexa PRO...

H/m
(SOLID)
45
40 24
35 20
30
16
Duty chart 25
20 12
15 8
10
4
5
0 0
0 400 800 1200 1600 2000 Q/m³/h 0 10 20 30 40 50 60 70 80 Q/m³/h

• Pumping of untreated sewage with solid constituents in For pumping in permanent operation of:
wastewater treatment plants and pumping stations • Wastewater and sewage
• Local drainage, water control and process water extraction • Wastewater containing faeces
• Applications in construction and industry • Sludges up to maximum 8% dry matter (depending on the
Application selected hydraulics)
out of sumps and vessels in municipal and industrial applica-
tions as well as to domestic and site drainage in accordance
with EN 12050 (observing regional-specific regulations and
instructions).
Submersible sewage pump for untreated sewage with SOLID
Submersible sewage pump for permanent operation, com-
Design impeller as a submersible monobloc unit for stationary and
pletely of cast iron
portable wet well and dry well installation
Qmax 2300 m3/h 75 m3/h
Hmax 50 m 29 m
• Impeller design non-susceptible to clogging • Submersible
• Very smooth operation • Vortex impeller non-susceptible to clogging
• Operation in wet and dry well installation • Seal by two mechanical seals
• Simple installation via suspension unit or pump base • Ex-rated in accordance with ATEX as standard
• Longitudinally watertight cable inlet (for FKT-, HC- and dry • Operation with frequency converter
Special fea-
motor) • IE3 motors available
tures/product
• Special materials (Abrasit) and Ceram coatings against • Optionally with installed external sealing chamber control
advantages
abrasion and corrosion for the oil barrier chamber
• Adaptation of the duty point by milling the impeller • Longitudinally watertight cable inlet
• Very smooth operation
• Easy installation via suspension unit or pump base
• Adaptation of the duty point by adapting the impeller
Further
Series information from page 14 Series information from page 37
information

12 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport

Series overview
Series Wilo-EMU FA 08... - 15... Wilo-EMU FA 20... - 25... Wilo-EMU FA 30... - 60...

Wastewater transport
Product photo
H/m

H/m

H/m
Wilo-EMU FA... Wilo-EMU FA... Wilo-EMU FA...
DN80 ... DN150 DN200 ... DN250 DN300 ... DN600
70 80
50 50
40
30
20
Duty chart 10 10 10

2
1 1 1
1 10 100 500 Q/l/s 1 10 100 500 Q/l/s 1 10 100 1000 Q/l/s

• Pumping of sewage with solid constit- • Pumping of sewage with solid constit- • Pumping of sewage with solid constit-
uents in water treatment systems and uents in water treatment systems and uents in water treatment systems and
pumping stations pumping stations pumping stations
Application • Local drainage, water control and • Local drainage, water control and • Local drainage and water control
process water extraction process water extraction • Industrial applications
• Applications in construction and • Applications in construction and
industry industry
Submersible sewage pump with dry Submersible sewage pump with various Submersible sewage pump with various
Design
motors or self-cooling motors cooling systems cooling systems
Qmax 690 m3/h 1680 m3/h 7950 m3/h
Hmax 95 m 83 m 87 m
• Operation in stationary and portable • Operation in stationary and portable • Operation in stationary wet well and
wet well and dry well installation wet well and dry well installation dry well installation
• Submersible • Submersible • Submersible
• Easy installation due to suspension • Easy installation due to suspension • Easy installation due to suspension
Special fea- unit or pump base unit or pump base unit or pump base
tures/product • Special materials and coatings against • Special materials and coatings against • Special materials and coatings against
advantages abrasion and corrosion abrasion and corrosion abrasion and corrosion
• Longitudinally watertight cable lead- • Longitudinally watertight cable lead- • Longitudinally watertight cable lead-
in (depending on motor) in (depending on motor) in (depending on motor)
• Adjustment of duty point by trimming • Adjustment of duty point by trimming • Adjustment of duty point by trimming
the impeller the impeller the impeller
Further
Series information from page 64 Series information from page 207 Series information from page 254
information

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 13
Wastewater transport
Sewage pumps with SOLID impeller

Series description Wilo-EMU FA…T

Wilo-EMU FA…T

y}Z
Design Technical data
Submersible sewage pump for untreated sewage with SOLID impeller • Mains connection: 3~400 V, 50 Hz
as a submersible monobloc unit for stationary and portable wet well • Immersed operating mode: S1
and dry well installation • Surfaced operating mode with self-cooling motor: S1
• Non-immersed operating mode with glanded motor: S2-15 min
Type key (depending on type)
• Protection class: IP 68
Example: Wilo-EMU FA 20.54T + FKT 27.1-4/28K Ex • Fluid temperature: 3 - 40°C; higher temperatures on request
Hydraulics: FA 20.54T • Sealing: With rotary shaft seal and mechanical seal, two mechanical
seals or one block seal cartridge, depending on the motor
FA Submersible sewage pump
• Free passage: 78x105 - 150x150 mm.
20 x10 = nominal diameter of the pressure port, e.g. • Permanently lubricated roller bearings
DN200 • Max. immersion depth: 20 m
54 Performance indicator
T SOLID impeller Materials
• Housing parts: EN-GJL or EN-GJS
• Impeller: EN-GJL or EN-GJS
Motor: FKT 27.1-4/28K Ex • Static seals: NBR
• Sealing on pump side: SiC/SiC
FKT Motor version
• Sealing on motor side: NBR or SiC/SiC
27 Size • Shaft: Stainless steel 1.4021, as of size 49: High-grade steel 1.7225
1 Distinctive number
4 Number of poles
Equipment/function
• Heavy-duty version made of cast iron
28 x10 = package length [mm] • Self-cooling motors with 1- or 2-chamber system
K Sealing version • Simple installation via suspension unit or pump base
Ex Ex-rated
Description/design
Submersible sewage pump as submersible monobloc unit for station-
Application ary and portable wet well and dry well installation. Portable installa-
• Pumping of untreated sewage with solid constituents in wastewater tion is possible, depending on type.
treatment plants and pumping stations
• Local drainage, water control and process water extraction Hydraulics
• Applications in construction and industry The outlet on the pressure side is designed as horizontal flange con-
nection. The maximum possible dry matter is 8 %. The new "SOLID"
Special features/product advantages impeller design is used as the impeller shape, which is characterised
• Impeller design non-susceptible to clogging by very smooth operation and a low susceptibility to blocking. De-
• Very smooth operation pending on the type of hydraulics, each hydraulic unit is equipped
• Operation in wet and dry well installation with a mobile and stationary wear ring. These contribute long-term
• Simple installation via suspension unit or pump base to ensuring the uniform efficiency of the unit.
• Longitudinally watertight cable inlet (for FKT-, HC- and dry motor)
• Special materials (Abrasit) and Ceram coatings against abrasion and Motor
corrosion Dry motors emit their heat directly to the surrounding fluid via the
• Adaptation of the duty point by milling the impeller housing part. For this reason, these motors can operated immersed in

14 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Sewage pumps with SOLID impeller

Series description Wilo-EMU FA…T

permanent operation (S1) and non-immersed in short-term opera- Scope of delivery


tion (S2). • Submersible sewage pump
• Cable length and accessories in accordance with customer require-
The self-cooling motors (FK, FKT, HC motors) transfer their waste ments
heat to the fluid being pumped by means of an integrated heat ex-

Wastewater transport
• Operating and maintenance manual
changer. As a result, these motors are suitable for permanent opera-
tion either in immersed or non-immersed state. Accessories
• Chains
All motors have a sealing chamber that protects the motor from fluid
• Suspension unit or pump base
ingress. It can be accessed from the outside and can be monitored
• Fixation sets with anchor bolts
with an optionally sealing chamber electrode.
• Switchgears, relays and plugs
All filling fluids used are potentially biodegradable and environmen-
tally safe. Commissioning
Operation in wet well installation with non-immersed motor:
The cable inlet on FKT, HC and dry motors is longitudinally water- The surfacing of self-cooling motors (FK, FKT, HC motors) is permit-
tight. Cable lengths can be individually configured. ted.

Sealing In dry motors (T-motor), it is possible to have the motor non-im-


Fluid-side and motor-side sealing is possible in the following ver- mersed for short periods if equipped with motor temperature moni-
sions depending on the motor type: toring with a temperature circuit, or with two temperature circuits
• Version H: Mechanical seal for the fluid side, rotary shaft seal for the when used in potentially explosive areas. The maximum running time
motor side with non-immersed motor depends on the medium and ambient
• Version G: Two independently operating mechanical seals temperatures. The exact specifications concerning the operating
• Version K: Block seal cartridge with two independently operating me- mode and time (e.g.. S2-15) can be found in the motor data for the
chanical seals respective hydraulic system.

Dry-running protection system:


Options The hydraulics housing must always be immersed. In the case of fluc-
• Special voltages e.g. 380 V, 415 V, 440 V tuating fluid levels, the system should shut down automatically once
• PTC thermistor sensor the minimum water submersion is reached. Please refer to the di-
• External sealing chamber monitoring mension drawings for this.
• Monitoring units for leakage and bearing temperature
• Ceram C0 coating against corrosion and Ceram C1-, C2-, C3 coatings Horizontal installation:
against abrasion (depending on size) Horizontal installation is not possible with these units!
• Ex-rated to ATEX or FM

H/m
Wilo-EMU FA...T
50 (SOLID)
45

40

DN 350
35
DN 150
30

25
DN 200
20

15

10
DN 250
5

0
0 400 800 1200 1600 2000 2400 Q/m³/h
0 100 200 300 400 500 600 700 Q/l/s

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 15
Wastewater transport
Sewage pumps with SOLID impeller

Pump curves, technical data Wilo-EMU FA 15.77T (1450 rpm)

Pump curves Wilo-EMU FA 15.77T - 50 Hz - 1450 rpm


SOLID impeller - Free passage: 80x120 mm

H[m]
56%
58% 60%
62% 64%
66%
45 68%
Ø 390
40
70%

35 Ø 370

30
64%
62% 60%
25
Ø 350
20
Ø 330

15
Ø 310
10

0
0 100 200 300 400 500 600 700 800 Q[m³/h]

0 40 80 120 160 200 Q[l/s]

P2 [kW]
Ø 350
Ø 390 Ø 370
60 Ø 330
Ø 310
40

20

0
0 100 200 300 400 500 600 700 800 Q[m³/h]

0 40 80 120 160 200 Q[l/s]

Hydraulic data

Wilo-EMU... Free passage Type of impeller Weight of hydraulic unit


BxH
mm kg
FA 15.77T 80x120 SOLID impeller 186
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

16 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Sewage pumps with SOLID impeller

Pump curves, technical data Wilo-EMU FA 15.77T (1450 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-

Wastewater transport
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 34.1-4/29 108 580 190 55.0 64.0 S1/S1 635 1252 998
FK 34.1-4/33 129 690 230 65.0 76.0 S1/S1 667 1252 998
FK 34.1-4/42 160 840 280 80.0 92.0 S1/S1 715 1372 1118
FKT 27.1-4/28 (Ex) 71 375 124 35.0 40.0 S1/S1 390 1246 820
FKT 27.2-4/32 (Ex) 77 470 160 39.0 44.0 S1/S1 470 1413 985
FKT 27.2-4/40 (Ex) 97 670 220 50.0 56.0 S1/S1 500 1413 985
T 24-4/36 (Ex) 68 480 159 34.0 39.0 S1/– 260 1001 748
T 30-4/29 (Ex) 78 440 146 40.0 45.5 S1/– 422 1035 781
T 30-4/35 (Ex) 96 540 179 50.0 57.0 S1/– 456 1095 841
T 30-4/44 (Ex) 116 680 225 62.0 69.0 S1/– 506 1185 931
T 30-4/55 (Ex) 146 820 275 78.0 87.0 S1/– 567 1295 1041
T 34-4/43 (Ex) 150 970 320 80.0 87.0 S1/– 596 1189 935
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 34.1... NBR - - SiC/SiC, SiC/SiC
FKT 27.1... NBR - - SiC/SiC, SiC/SiC
FKT 27.2... NBR - - SiC/SiC, SiC/SiC
T 24... NBR - - SiC/SiC, SiC/SiC
T 30... NBR - - SiC/SiC, SiC/SiC
T 34... NBR - - SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 34.1... - - • • • – ǽ -
FKT 27.1... ǽ ǽ • • ǽ • - •
FKT 27.2... ǽ ǽ • • ǽ • - •
T 24... ǽ ǽ • ǽ ǽ – ǽ ǽ
T 30... ǽ ǽ • ǽ ǽ – ǽ ǽ
T 34... ǽ ǽ • ǽ ǽ – ǽ ǽ
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 17
Wastewater transport
Sewage pumps with SOLID impeller

Dimensions Wilo-EMU FA 15.77T (1450 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

DN150L/ 2RK 530


210
1000 1000 149
90 90
120
DN150L/ 2RK 842 95 DN150S/ 2RK

19
842

560
110

240
ø42,4x2

50

50
ø60,3x3,65
220
740
88 89 241 DN150S/ 2RK 18

AW
AW

38 291
62
120
1 1

100
91

220
230

140
660

280
140
465

540
191
191

320
320
481

490

420
70
70

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

318
Ø 603

450
753
453
743

2
3

190

710

Dimension drawing Wilo-EMU FA - stationary dry well installation

22

2
570
1000
920

490
493

747

4
5

710

1 = DN150 PN10 / ANSI B16.1, Class 125, Size 6; 2 = DN200 PN10 / ANSI B16.1, Class 125, Size 8; 3 = DN200 PN10; 4 = DN250 PN10 / ANSI B16.1, Class 125, Size 10;
5 = DN250 PN10

18 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Sewage pumps with SOLID impeller

Pump curves, technical data Wilo-EMU FA 15.95T (1450 rpm)

Pump curves Wilo-EMU FA 15.95T - 50 Hz - 1450 rpm


SOLID impeller - Free passage: 78x105 mm

H[m]

Wastewater transport
36

32
55% 59%
62% 65%
28 68%
71%
73%
74,5%
24
74,5%
73%
20
75,5%
76,5%
Ø 310
16
Ø 300

12 Ø 290
Ø 280
Ø 270
8

0
0 100 200 300 400 500 600 Q[m³/h]

0 20 40 60 80 100 120 140 160 180 Q[l/s]

P2 [kW]
Ø 310
Ø 300
30 Ø 290
Ø 280
20 Ø 270

10

0
0 100 200 300 400 500 600 Q[m³/h]

0 20 40 60 80 100 120 140 160 180 Q[l/s]

Hydraulic data

Wilo-EMU... Free passage Type of impeller Weight of hydraulic unit


BxH
mm kg
FA 15.95T 78x105 SOLID impeller 161
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 19
Wastewater transport
Sewage pumps with SOLID impeller

Pump curves, technical data Wilo-EMU FA 15.95T (1450 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 202-4/27 37.5 148 49 18.5 23.0 S1/S1 155 871 764
FKT 27.1-4/22 (Ex) 53 295 98 26.0 30.0 S1/S1 370 1246 820
FKT 27.1-4/28 (Ex) 71 375 124 35.0 40.0 S1/S1 390 1246 820
HC 20.1-4/30 (Ex) 41 220 74 20.0 24.0 S1/S1 204 935 830
T 20.1-4/30 (Ex) 41 220 73 20.0 24.0 S1/S2-15 min 182 764 674
T 24-4/29 (Ex) 49.5 320 106 25.0 28.5 S1/– 233 931 678
T 24-4/36 (Ex) 68 480 159 34.0 39.0 S1/– 260 1001 748
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 202... NBR - - SiC/SiC, SiC/SiC
FKT 27.1... NBR - - SiC/SiC, SiC/SiC
HC 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC
T 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC
T 24... NBR - - SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 202... - - • ǽ ǽ – - -
FKT 27.1... ǽ ǽ • • ǽ • - •
HC 20.1... ǽ ǽ • • ǽ • - •
T 20.1... ǽ ǽ • • ǽ • - •
T 24... ǽ ǽ • ǽ ǽ – ǽ ǽ
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

20 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Sewage pumps with SOLID impeller

Dimensions Wilo-EMU FA 15.95T (1450 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

1000

Wastewater transport
861

90/ 95

210
ø42,4x2
90 149
AW

220

110

240
19
88

50

50
38
1
99

465
170
419

320

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

375
660

450
773
433
722

2
3

190

710

Dimension drawing Wilo-EMU FA - portable installation


375
660

450
773
459

360
190

Ø 500

1 = DN150 PN10 / ANSI B16.1, Class 125, Size 6; 2 = DN200 PN10 / ANSI B16.1, Class 125, Size 8; 3 = DN200 PN10

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 21
Wastewater transport
Sewage pumps with SOLID impeller

Pump curves, technical data Wilo-EMU FA 20.54T (1450 rpm)

Pump curves Wilo-EMU FA 20.54T - 50 Hz - 1450 rpm


SOLID impeller - Free passage: 78x105 mm

H[m]
36

32
40%
50%
60%
28 66%
70%
73%
75%
24
Ø 310
76%
75%
20
77%
73%
16
70%
66%
12
Ø 300
60% Ø 290
8
Ø 280
4
Ø 270

0
0 100 200 300 400 500 600 700 Q[m³/h]

0 40 80 120 160 200 Q[l/s]

P2 [kW] Ø 300
Ø 310
30
Ø 290
Ø 280
20
Ø 270

10

0
0 100 200 300 400 500 600 700 Q[m³/h]

0 40 80 120 160 200 Q[l/s]

Hydraulic data

Wilo-EMU... Free passage Type of impeller Weight of hydraulic unit


BxH
mm kg
FA 20.54T 78x105 SOLID impeller 135
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

22 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Sewage pumps with SOLID impeller

Pump curves, technical data Wilo-EMU FA 20.54T (1450 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-

Wastewater transport
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 202-4/27 37.5 148 49 18.5 23.0 S1/S1 155 871 764
FKT 27.1-4/22 (Ex) 53 295 98 26.0 30.0 S1/S1 370 1246 820
FKT 27.1-4/28 (Ex) 71 375 124 35.0 40.0 S1/S1 390 1246 820
HC 20.1-4/30 (Ex) 41 220 74 20.0 24.0 S1/S1 204 935 830
T 20.1-4/30 (Ex) 41 220 73 20.0 24.0 S1/S2-15 min 182 764 674
T 24-4/29 (Ex) 49.5 320 106 25.0 28.5 S1/– 233 931 678
T 24-4/36 (Ex) 68 480 159 34.0 39.0 S1/– 260 1001 748
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 202... NBR - - SiC/SiC, SiC/SiC
FKT 27.1... NBR - - SiC/SiC, SiC/SiC
HC 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC
T 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC
T 24... NBR - - SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 202... - - • ǽ ǽ – - -
FKT 27.1... ǽ ǽ • • ǽ • - •
HC 20.1... ǽ ǽ • • ǽ • - •
T 20.1... ǽ ǽ • • ǽ • - •
T 24... ǽ ǽ • ǽ ǽ – ǽ ǽ
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 23
Wastewater transport
Sewage pumps with SOLID impeller

Dimensions Wilo-EMU FA 20.54T (1450 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

1000
105
115

785 105
ø42,4x2

120

270

600
290
120
AW

92 285
56 2

25
97

250
560

550
172
477

300
80

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

358
605

1
435

400
722

1
693
2

190

660

Dimension drawing Wilo-EMU FA - portable installation


358
605

400
459

362

693
190

Ø 500

1 = DN200 PN10 / ANSI B16.1, Class 125, Size 8; 2 = DN200 PN10

24 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Sewage pumps with SOLID impeller

Pump curves, technical data Wilo-EMU FA 25.93T (950 rpm)

Pump curves Wilo-EMU FA 25.93T - 50 Hz - 950 rpm


SOLID impeller - Free passage: 105x120 mm

H[m]

Wastewater transport
28

24 55%
61%
64%
67%
70%
73%
20
76%

16

12 70%
67%
64%
61%
8
55%

Ø 450
4 Ø 440
Ø 400 Ø 420
Ø 380

0
0 200 400 600 800 1000 1200 1400 Q[m³/h]

0 50 100 150 200 250 300 350 400 Q[l/s]

P2[kW]

40 Ø 450
Ø 440
30 Ø 420
Ø 400
20 Ø 380

10

0
0 200 400 600 800 1000 1200 1400 Q[m³/h]

0 50 100 150 200 250 300 350 400 Q[l/s]

Hydraulic data

Wilo-EMU... Free passage Type of impeller Weight of hydraulic unit


BxH
mm kg
FA 25.93T 105x120 SOLID impeller 350
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 25
Wastewater transport
Sewage pumps with SOLID impeller

Pump curves, technical data Wilo-EMU FA 25.93T (950 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 34.1-6/29 95 450 149 47.5 56.0 S1/S1 635 1252 998
FK 34.1-6/33 109 495 164 55.0 64.0 S1/S1 667 1252 998
FK 34.1-6/42 129 610 205 65.0 75.0 S1/S1 715 1372 1118
FKT 27.2-6/32 (Ex) 61 440 150 30.0 35.5 S1/S1 470 1413 985
FKT 27.2-6/40 (Ex) 74 520 175 36.5 42.0 S1/S1 500 1413 985
T 30-6/28 (Ex) 60 330 109 30.0 34.0 S1/– 416 1035 781
T 30-6/35 (Ex) 75 410 136 37.5 42.5 S1/– 456 1095 841
T 30-6/41 (Ex) 88 480 159 44.0 49.5 S1/– 471 1185 931
T 30-6/48 (Ex) 102 580 192 52.0 58.0 S1/– 531 1295 1041
T 34-6/41 (Ex) 124 670 225 65.0 70.0 S1/– 581 1189 935
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 34.1... NBR - - SiC/SiC, SiC/SiC
FKT 27.2... NBR - - SiC/SiC, SiC/SiC
T 30... NBR - - SiC/SiC, SiC/SiC
T 34... NBR - - SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 34.1... - - • • • – ǽ -
FKT 27.2... ǽ ǽ • • ǽ • - •
T 30... ǽ ǽ • ǽ ǽ – ǽ ǽ
T 34... ǽ ǽ • ǽ ǽ – ǽ ǽ
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

26 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Sewage pumps with SOLID impeller

Dimensions Wilo-EMU FA 25.93T (950 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

Wastewater transport
1400 x 1200
105
1172
ø42,4x2 135

378 105

120
60

640
340
270
99 2
AW

120
137

25
300
600
250

600
567

3
178

180

Dimension drawing Wilo-EMU FA - stationary dry well installation

22
> 420
M20
A

523
930

1100
680

600

1200
1

> 420

630
420
1073
587

470
735

1100
1200
> 1520
4

1184
1 = DN250 PN10 / ANSI B16.1, Class 125, Size 10; 2 = DN250 PN10; 3 = DN300 PN10 / ANSI B16.1, Class 125, Size 12; 4 = DN300 PN10

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 27
Wastewater transport
Sewage pumps with SOLID impeller

Pump curves, technical data Wilo-EMU FA 25.93T (1450 rpm)

Pump curves Wilo-EMU FA 25.93T - 50 Hz - 1450 rpm


SOLID impeller - Free passage: 95x125 mm

H[m]

40

35 56%
60%
64%
66%
68%
30 70%
72%
74%
76%
25

20

70%
68%
15 66%
64%
60%
56%
10 Ø 370
Ø 360

5 Ø 350

0
0 200 400 600 800 1000 1200 1400 Q[m³/h]

0 50 100 150 200 250 300 350 400 Q[l/s]

P2[kW]

Ø 370
60 Ø 360
Ø 350
40

20

0
0 200 400 600 800 1000 1200 1400 Q[m³/h]

0 50 100 150 200 250 300 350 400 Q[l/s]

Hydraulic data

Wilo-EMU... Free passage Type of impeller Weight of hydraulic unit


BxH
mm kg
FA 25.93T 95x125 SOLID impeller 350
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

28 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Sewage pumps with SOLID impeller

Pump curves, technical data Wilo-EMU FA 25.93T (1450 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-

Wastewater transport
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 34.1-4/33 129 690 230 65.0 76.0 S1/S1 667 1252 998
FK 34.1-4/42 160 840 280 80.0 92.0 S1/S1 715 1372 1118
T 30-4/44 (Ex) 116 680 225 62.0 69.0 S1/– 506 1185 931
T 30-4/55 (Ex) 146 820 275 78.0 87.0 S1/– 567 1295 1041
T 34-4/43 (Ex) 150 970 320 80.0 87.0 S1/– 596 1189 935
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 34.1... NBR - - SiC/SiC, SiC/SiC
T 30... NBR - - SiC/SiC, SiC/SiC
T 34... NBR - - SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 34.1... - - • • • – ǽ -
T 30... ǽ ǽ • ǽ ǽ – ǽ ǽ
T 34... ǽ ǽ • ǽ ǽ – ǽ ǽ
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 29
Wastewater transport
Sewage pumps with SOLID impeller

Dimensions Wilo-EMU FA 25.93T (1450 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

1400 x 1200
105
1172
ø42,4x2 135

378 105

120
60

640
340
270
99 2
AW

120
137

25
300
600
250

600
567

3
178

180

Dimension drawing Wilo-EMU FA - stationary dry well installation

22
> 420

M20
A

523
930

1100
680

600

1200
1

> 420

630
420
1073
587

470
735

1100
1200
> 1520
4

1184
1 = DN250 PN10 / ANSI B16.1, Class 125, Size 10; 2 = DN250 PN10; 3 = DN300 PN10 / ANSI B16.1, Class 125, Size 12; 4 = DN300 PN10

30 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Sewage pumps with SOLID impeller

Pump curves, technical data Wilo-EMU FA 35.54T (950 rpm)

Pump curves Wilo-EMU FA 35.54T - 50 Hz - 950 rpm


SOLID impeller - Free passage: 150x150 mm

H[m]

Wastewater transport
40

35
55%
60%
65%
70%
30
73%
76%

80%
25

20

15 73%
70%

10 ø 535
ø 510

5
ø 478

0
0 400 800 1200 1600 2000 2400 Q[m³/h]

0 100 200 300 400 500 600 700 Q[l/s]

P2[kW]

120
ø 535
ø 510
80

40
ø 478

0
0 400 800 1200 1600 2000 2400 Q[m³/h]

0 100 200 300 400 500 600 700 Q[l/s]

Hydraulic data

Wilo-EMU... Free passage Type of impeller Weight of hydraulic unit


BxH
mm kg
FA 35.54T 150x150 SOLID impeller 830
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 31
Wastewater transport
Sewage pumps with SOLID impeller

Pump curves, technical data Wilo-EMU FA 35.54T (950 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 34.1-6/42 129 610 205 65.0 75.0 S1/S1 715 1372 1118
FK 34.1-6/50 151 720 240 75.0 86.0 S1/S1 780 1452 1198
FK 34.1-6/60 181 860 285 90.0 103.0 S1/S1 860 1547 1293
FK 42.1-6/46 235 1270 420 110.0 125.0 S1/S1 1300 1512 1195
FK 42.1-6/50 280 1490 495 132.0 149.0 S1/S1 1345 1667 1350
FKT 50.1-6/50 245 1510 500 135.0 143.0 S1/S1 2397 2317 1433
T 34-6/41 (Ex) 124 670 225 65.0 70.0 S1/– 581 1189 935
T 34-6/50 (Ex) 136 790 265 70.0 78.0 S1/– 647 1259 1005
T 42-6/36 182 910 305 90.0 98.0 S1/– 1020 1607 1107
T 42-6/46 220 1100 365 110.0 120.0 S1/– 1120 1707 1207
T 42-6/52 270 1330 445 132.0 144.0 S1/– 1180 1757 1257
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 34.1... NBR - - SiC/SiC, SiC/SiC
FK 42.1... NBR - SiC/SiC, SiC/SiC -
FKT 50.1… NBR - SiC/SiC, SiC/SiC -
T 34... NBR - - SiC/SiC, SiC/SiC
T 42... NBR - SiC/SiC, SiC/SiC -

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 34.1... - - • • • – ǽ -
FK 42.1... - - • • • – ǽ -
FKT 50.1… ǽ ǽ • • – • ǽ •
T 34... ǽ ǽ • ǽ ǽ – ǽ ǽ
T 42... ǽ - • ǽ ǽ – ǽ ǽ
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

32 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Sewage pumps with SOLID impeller

Dimensions Wilo-EMU FA 35.54T (950 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

2000 x 1500

Wastewater transport
160
486

Ø26
ø60,3x3,65
1461 160

107 386

1020
400
AW

200

500
300

200
61
1
225

650
750

1100
380

350
955

380

Dimension drawing Wilo-EMU FA - stationary dry well installation

700
620
716
1229
588

1170
1090

1
866

2
780
22
3

1354

1280

1 = DN350 PN10 / ANSI B16.1, Class 125, Size 14; 2 = DN400 PN10 / ANSI B16.1, Class 125, Size 16; 3 = DN400 PN10

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 33
Wastewater transport
Sewage pumps with SOLID impeller

Pump curves, technical data Wilo-EMU FA 35.67T (1450 rpm)

Pump curves Wilo-EMU FA 35.67T - 50 Hz - 1450 rpm


SOLID impeller - Free passage: 150x120 mm

H[m]

50
70% 76%
45
79%
40

35
70%
30

25
Ø 485
20
Ø 460
15 Ø 440

Ø 420
10

0
800 1200 1600 2000 2400 Q[ m³/h]

300 400 500 600 700 Q [l/s]

P2[kW]
Ø 485
200
Ø 460
150 Ø 440
Ø 420
100

50

0
800 1200 1600 2000 2400 Q[ m³/h]

300 400 500 600 700 Q [l/s]

Hydraulic data

Wilo-EMU... Free passage Type of impeller Weight of hydraulic unit


BxH
mm kg
FA 35.67T 150x120 SOLID impeller 830
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

34 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Sewage pumps with SOLID impeller

Pump curves, technical data Wilo-EMU FA 35.67T (1450 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-

Wastewater transport
immersed)
IN IA P2 P1 A AW
A kW kg mm
FKT 50.1-4/42 240 1570 525 140.0 148.0 S1/S1 2242 2217 1333
FKT 50.1-4/50 285 2040 680 165.0 173.0 S1/S1 2384 2317 1433
FKT 50.1-4/57 340 2480 830 200.0 210.0 S1/S1 2536 2407 1523
FKT 50.1-4/59 395 2740 920 230.0 245.0 S1/S1 2536 2407 1523
T 50.1-4/42 300 2050 690 170.0 178.0 S1/– 1906 2217 1333
T 50.1-4/50 355 2090 700 205.0 215.0 S1/– 2040 2317 1433
T 50.1-4/57 420 3010 1000 245.0 260.0 S1/– 2183 2407 1523
T 50.1-4/59 445 2990 1000 260.0 275.0 S1/– 2183 2407 1523
T 56-4/49 520 3230 1080 290.0 305.0 S1/– 2160 2196 1386
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FKT 50.1… NBR - SiC/SiC, SiC/SiC -
T 50.1… NBR - SiC/SiC, SiC/SiC -
T 56... NBR - SiC/SiC, SiC/SiC -

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FKT 50.1… ǽ ǽ • • – • ǽ •
T 50.1… ǽ ǽ • • • • ǽ •
T 56... - - • • • – ǽ ǽ
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 35
Wastewater transport
Sewage pumps with SOLID impeller

Dimensions Wilo-EMU FA 35.67T (1450 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

2000 x 1500
160
486

Ø26
ø60,3x3,65
1461 160

107 386

1020
400
AW

200

500
300

200
61
1
225

650
750

1100
380

350
955

380

Dimension drawing Wilo-EMU FA - stationary dry well installation

700
620
716
1229
588

1170
1090

1
866

2
780
22
3

1354

1280

1 = DN350 PN10 / ANSI B16.1, Class 125, Size 14; 2 = DN400 PN10 / ANSI B16.1, Class 125, Size 16; 3 = DN400 PN10

36 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 50 to DN 80

Series description Wilo-Rexa PRO

Wilo-Rexa PRO

Wastewater transport
y{}
Design Example:
Submersible sewage pump for permanent operation, completely of Wilo-Rexa PRO V06PA-110/EAD1X2-T0015-540-O
cast iron O Additional electrical equipment
O = with bare cable end
Type key F = float switch with bare cable end
Example: A = float switch with plug
Wilo-Rexa PRO V06PA-110/EAD1X2-T0015-540-O P = with plug
PRO Series name
Application
V Vortex impeller For pumping in permanent operation of:
06 Nominal diameter of pressure connection e.g. DN 65 • Wastewater and sewage
P Hydraulic version
• Wastewater containing faeces
P = for wet well installation, suction side not drilled
• Sludges up to maximum 8% dry matter (depending on the selected
hydraulics)
D = suction side drilled in accordance with DIN
out of sumps and vessels in municipal and industrial applications as
N = suction side drilled in accordance with ANSI (North
well as to domestic and site drainage in accordance with EN 12050
American Standard)
(observing regional-specific regulations and instructions).
A Material version, hydraulics
110 Hydraulics intended use Special features/product advantages
E Motor version • Submersible
E = glanded motor • Vortex impeller non-susceptible to clogging
R = reduced-power motor • Seal by two mechanical seals
A Material version, motor
• Ex-rated in accordance with ATEX as standard
• Operation with frequency converter
D Sealing version • IE3 motors available
D = with two independent mechanical seals • Optionally with installed external sealing chamber control for the oil
1 IE efficiency class, e.g. 1 = IE1 (derived from IEC 60034-30) barrier chamber
• Longitudinally watertight cable inlet
X Ex-rated
• Very smooth operation
X = ATEX
• Easy installation via suspension unit or pump base
F = FM
• Adaptation of the duty point by adapting the impeller
C = CSA
2 Number of poles
Technical data
T Mains connection version: • Mains connection: 1~230 V, 50 Hz or 3~400 V, 50 Hz
M = 1~ • Immersed operating mode: S1
T = 3~ • Non-immersed operating mode: S2-30 min; S3 25%
0015 Value/10 = rated motor power P2 in kW • Protection class: IP 68
• Insulation class: F
5 Frequency (5 = 50 Hz, 6 = 60 Hz)
• Fluid temperature: 3 - 40°C, max. 60°C for 3 min
40 Key for rated voltage • Free passage: 50 / 65 / 80 mm
• Max. immersion depth: 20 m

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 37
Wastewater transport
Submersible pumps for sewage DN 50 to DN 80

Series description Wilo-Rexa PRO

Materials Options
• Motor housing: EN-GJL-250 • PTC temperature sensor for winding monitoring
• Hydraulic housing: EN-GJL250 • Motor windings to insulation class "H“
• Impeller: EN-GJL250 • Special voltages
• Static seals: NBR • Static seals of Viton
• Sealing on pump side: SiC/SiC • Motor-side seal in SiC/SiC
• Sealing on motor side: C/MgSiO4 • Coating Ceram C0 for housing and impeller
• Shaft end: Stainless steel 1.4021 • Adaptation of the duty point by adapting the impeller
• Customer-specific versions
Equipment/function • Accessories fitted
• Leakage detection for the motor compartment
• Winding temperature monitoring with bimetal sensor as standard or Scope of delivery
PTC sensor as an option • Submersible sewage pump with attached accessories (e.g. pump
• Optionally with installed external sealing chamber control for the oil base, plug, switchgear, sealing chamber monitoring)
barrier chamber • Cable type and length as requested
• Operating and maintenance manual
Description/design
Submersible sewage pump as submersible monobloc unit for station- Accessories
ary and portable wet well installation in permanent operation. • Suspension unit or pump base
• External sealing chamber monitoring for monitoring the oil barrier
Hydraulics chamber
The outlet on the pressure side is designed as horizontal flange con- • Ceram coating
nection. The maximum possible dry matter is 8 % (depending on the • Chains
hydraulics) Vortex impellers are used as the impeller shape. • Switchgears, relays and plugs
• Fixation sets with anchor bolts
Motor
The motors available are glanded motors in single-phase version Commissioning
(with built-in operation capacitor in external switchgear) and three- Operation in wet well installation with non-immersed motor:
phase version for the direct starting. The waste heat is given off di- The motor can be run non-immersed. The operating times here are
rectly to the surrounding fluid via the motor housing. These motors dependent on the rated motor power and are defined by the informa-
can operated immersed in permanent operation (S1) and non-im- tion in the "Operating mode for non-immersed operation". This in-
mersed in short-term operation (S2) or intermittent operation (S3). formation must be strictly observed!
• Note for intermittent operation S3: By default, the maximum operat-
Furthermore the motors are equipped with the following monitoring ing time is 2.5 minutes in S3 operation (S3 25%). If the motor is com-
devices: pletely immersed for 1 minute before a re-start and the necessary
• Leakage detection motor compartment cooling of the motor has thus taken place, the maximum running
The leakage detection signals water ingress into the motor compart- time in S3 operation can be 5 minutes (S3 50%)!
ment. • The maximum fluid temperature is 40 °C.
• Thermal motor monitoring
The thermal motor monitoring protects the motor windings against Dry-running protection:
overheating. Bimetal sensors are used for this as standard. Optionally The hydraulics housing must always be immersed. In the case of fluc-
PTC sensors can be fitted. tuating fluid levels, the system should shut down automatically once
the minimum water submersion is reached. Please refer to the di-
In addition the motor can be equipped with an external sealing cham- mension drawings for this.
ber electrode for monitoring the oil barrier chamber. This signals if
there is water ingress into the oil barrier chamber through the me- Horizontal installation:
chanical seal on the fluid side.
Horizontal installation is not possible!
The connecting cable has bare cable ends as standard and is cast as
Dry well installation:
longitudinally watertight. The cable length is made in fixed lengths
Dry well installation is possible. The operating times here are de-
up to 50 metres; from 50 metres as per customer request.
pendent on the rated motor power and are defined by the informa-
tion in the "Operating mode for non-immersed operation". This in-
Seal
formation must be strictly observed!
There is an oil barrier chamber between the motor and hydraulics.
• The maximum fluid temperature is 40 °C.
This is filled with medicinal white oil. The fluid-side and motor-side
• The maximum ambient temperature is 40 °C (in accordance with
seals are provided by two mechanical seals which rotate independ-
EN 60335-1). Higher ambient temperatures are possible on request.
ently of each other.

38 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 50 to DN 80

Series description Wilo-Rexa PRO


H/m

Wilo-Rexa PRO...
28

Wastewater transport
24

DN 50
20

16

DN 65
12

8
DN 80

0
0 10 20 30 40 50 60 70 80 90 Q/m³/h

0 2 4 6 8 10 12 14 16 18 20 22 24 26 Q/l/s

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 39
Wastewater transport
Submersible pumps for sewage DN 50 to DN 80

Pump curves, technical data Wilo-Rexa PRO V05..-12.. (2900 rpm)

Pump curves Wilo-Rexa PRO V05..-12.. - 50 Hz - 2900 rpm


Vortex impeller - Free ball passage: 50 mm

H[m]

12
25%
30%
35%
10
38%
40%

2
V05..-126
V05..-124
V05..-122

0
0 5 10 15 20 25 30 35 40 Q[m³/h]

0 2 4 6 8 10 Q[l/s]

P2[kW]

1,2
V05..-126

0,8
V05..-124

0,4 V05..-122

0
0 5 10 15 20 25 30 35 40 Q[m³/h]

0 2 4 6 8 10 Q[l/s]

Hydraulic data

Wilo-Rexa... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
PRO V05..-12.. 50 Vortex impeller 13
Pump curves apply to 1~230 V, 50 Hz or 3~400 V, 50 Hz, at nominal speed and a density of 1 kg/dm3. Pump curves according to ISO 9906, appendix A. The specified
degrees of efficiency correspond to the hydraulic efficiency.

40 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 50 to DN 80

Pump curves, technical data Wilo-Rexa PRO V05..-12.. (2900 rpm)

Motor data

Nominal Starting cur- Starting cur- Nominal Power Operating Motor Dimen-
current rent - direct rent - star- motor pow- consump- mode (im- weight sions
delta er tion mersed/non-

Wastewater transport
immersed)
IN IA P2 P1 A
A kW kg mm
S1/S2-30 min
P 13.1-08/EAD0X2-M 7.2 29 – 1.10 1.59 32 373
S3-25%
S1/S2-30 min
P 13.1-08/EAD1X2-T 2.55 20 – 1.10 1.45 32 373
S3-25%
S1/S2-30 min
P 13.1-08/EAD0X2-M 9.3 29 – 1.50 2.10 32 373
S3-25%
S1/S2-30 min
P 13.1-08/EAD1X2-T 3.3 20 – 1.50 1.97 32 373
S3-25%
S1/S2-30 min
P 13.1-09/EAD3X2-T 2.55 20 – 1.10 1.34 32 373
S3-25%
P 13.1-09/EAD3X2-T 2.65 20 – 1.20 1.45 S1/S1 32 373
S1/S2-30 min
P 13.1-09/EAD3X2-T 3.15 20 – 1.50 1.81 32 373
S3-25%
P1 refers to the maximum power consumption. All of the data applies to 1~230 V, 50 Hz or 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Mechanical seal Sealing on motor side


P 13… NBR SiC/SiC Carbon/steatite

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
P 13… • - • • ǽ – - -
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 41
Wastewater transport
Submersible pumps for sewage DN 50 to DN 80

Dimensions Wilo-Rexa PRO V05..-12.. (2900 rpm)

Dimension drawing Wilo-Rexa PRO V05 - stationary wet well installation

Ø26,9 x 2,0
150 54 148 > 250
173
102 57
15
165

202
125

150
175
DN50

308
510
33
19

123
S1 577
A

S2, S3
300

>50
209

160
82

>85

33

Dimension drawing Wilo-Rexa PRO V05 - stationary dry well installation

300
A

200
126

150
480

250
330
~235
95

Dimension drawing Wilo-Rexa PRO V05 - transportable wet well installation

S1

150
A

DN 50/ Rp 2
S2, S3
300

PN 16
251
196

148
70

300

Ø 300

42 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 50 to DN 80

Pump curves, technical data Wilo-Rexa PRO V05..-22.. (2900 rpm)

Pump curves Wilo-Rexa PRO V05..-22.. - 50 Hz - 2900 rpm


Vortex impeller - Free ball passage: 50 mm

H[m]

Wastewater transport
28

35%
40%
24
43%
45%
20
47%
V05..-228

16

12 V05..-226
43%
40%
8
35% V05..-224

4
V05..-222

0
0 10 20 30 40 50 Q[m³/h]

0 2 4 6 8 10 12 14 Q[l/s]

P2[kW]
V05..-228
V05..-226
3
V05..-224
V05..-222
2

0
0 10 20 30 40 50 Q[m³/h]

0 2 4 6 8 10 12 14 Q[l/s]

Hydraulic data

Wilo-Rexa... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
PRO V05..-22.. 50 Vortex impeller 14
Pump curves apply to 1~230 V, 50 Hz or 3~400 V, 50 Hz, at nominal speed and a density of 1 kg/dm3. Pump curves according to ISO 9906, appendix A. The specified
degrees of efficiency correspond to the hydraulic efficiency.

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 43
Wastewater transport
Submersible pumps for sewage DN 50 to DN 80

Pump curves, technical data Wilo-Rexa PRO V05..-22.. (2900 rpm)

Motor data

Nominal Starting cur- Starting cur- Nominal Power Operating Motor Dimen-
current rent - direct rent - star- motor pow- consump- mode (im- weight sions
delta er tion mersed/non-
immersed)
IN IA P2 P1 A
A kW kg mm
S1/S2-30 min
P 13.1-08/EAD0X2-M 7.2 29 – 1.10 1.59 32 373
S3-25%
S1/S2-30 min
P 13.1-08/EAD1X2-T 2.55 20 – 1.10 1.45 32 373
S3-25%
S1/S2-30 min
P 13.1-08/EAD0X2-M 9.3 29 – 1.50 2.10 32 373
S3-25%
S1/S2-30 min
P 13.1-08/EAD1X2-T 3.3 20 – 1.50 1.97 32 373
S3-25%
S1/S2-30 min
P 13.1-09/EAD3X2-T 2.55 20 – 1.10 1.34 32 373
S3-25%
S1/S2-30 min
P 13.1-09/EAD3X2-T 3.15 20 – 1.50 1.81 32 373
S3-25%
S1/S2-30 min
P 13.1-10/EAD1X2-T 5.2 31 – 2.50 3.15 36 458
S3-25%
S1/S2-30 min
P 13.1-11/EAD3X2-T 5.1 31 – 2.50 3.05 36 458
S3-25%
S1/S2-30 min
P 13.1-15/EAD1X2-T 7.8 66 – 3.90 4.75 40 458
S3-25%
S1/S2-30 min
P 13.1-16/EAD3X2-T 7.8 66 – 3.90 4.60 40 458
S3-25%
P 13.1-16/EAD3X2-T 4.3 66 – 1.65 1.95 S1/S1 40 458
P1 refers to the maximum power consumption. All of the data applies to 1~230 V, 50 Hz or 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Mechanical seal Sealing on motor side


P 13… NBR SiC/SiC Carbon/steatite

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
P 13… • - • • ǽ – - -
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

44 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 50 to DN 80

Dimensions Wilo-Rexa PRO V05..-22.. (2900 rpm)

Dimension drawing Wilo-Rexa PRO V05 - stationary wet well installation

Ø26,9 x 2,0

Wastewater transport
15054 148 > 250
173
102 57
15
165

202
125

175
150
DN50 33

308
510
19

123
S1 577
A

S2, S3
>50
300
209

160
75

>85

33

Dimension drawing Wilo-Rexa PRO V05 - stationary dry well installation

300
A

202
133

150
480

252
330
~235
95

Dimension drawing Wilo-Rexa PRO V05 - transportable wet well installation

S1

150
A

DN 50/ Rp 2
S2, S3
300

PN 16
258
203

155
70

300

Ø 300

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 45
Wastewater transport
Submersible pumps for sewage DN 50 to DN 80

Pump curves, technical data Wilo-Rexa PRO V06..-21.. (2900 rpm)

Pump curves Wilo-Rexa PRO V06..-21.. - 50 Hz - 2900 rpm


Vortex impeller - Free ball passage: 65 mm

H[m]

16

29%
34%
14
39%
42%
44%
12

10

29%
4

2 V06..-216
V06..-212 V06..-214

0
0 10 20 30 40 50 60 Q[m³/h]

0 2 4 6 8 10 12 14 16 18 Q[l/s]

P2[kW]

V06..-216
1,5
V06..-214
1,0
V06..-212
0,5

0
0 10 20 30 40 50 60 Q[m³/h]

0 2 4 6 8 10 12 14 16 18 Q[l/s]

Hydraulic data

Wilo-Rexa... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
PRO V06..-21.. 65 Vortex impeller 14
Pump curves apply to 1~230 V, 50 Hz or 3~400 V, 50 Hz, at nominal speed and a density of 1 kg/dm3. Pump curves according to ISO 9906, appendix A. The specified
degrees of efficiency correspond to the hydraulic efficiency.

46 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 50 to DN 80

Pump curves, technical data Wilo-Rexa PRO V06..-21.. (2900 rpm)

Motor data

Nominal Starting cur- Starting cur- Nominal Power Operating Motor Dimen-
current rent - direct rent - star- motor pow- consump- mode (im- weight sions
delta er tion mersed/non-

Wastewater transport
immersed)
IN IA P2 P1 A
A kW kg mm
S1/S2-30 min
P 13.1-08/EAD0X2-M 7.2 29 – 1.10 1.59 32 373
S3-25%
S1/S2-30 min
P 13.1-08/EAD1X2-T 2.55 20 – 1.10 1.45 32 373
S3-25%
S1/S2-30 min
P 13.1-08/EAD0X2-M 9.3 29 – 1.50 2.10 32 373
S3-25%
S1/S2-30 min
P 13.1-08/EAD1X2-T 3.3 20 – 1.50 1.97 32 373
S3-25%
S1/S2-30 min
P 13.1-09/EAD3X2-T 2.55 20 – 1.10 1.34 32 373
S3-25%
P 13.1-09/EAD3X2-T 2.65 20 – 1.20 1.45 S1/S1 32 373
S1/S2-30 min
P 13.1-09/EAD3X2-T 3.15 20 – 1.50 1.81 32 373
S3-25%
S1/S2-30 min
P 13.1-10/EAD1X2-T 5.2 31 – 2.50 3.15 36 458
S3-25%
P 13.1-11/EAD3X2-T 3.2 31 – 1.35 1.65 S1/S1 36 458
S1/S2-30 min
P 13.1-11/EAD3X2-T 5.1 31 – 2.50 3.05 36 458
S3-25%
P 13.1-16/EAD3X2-T 4.3 66 – 1.65 1.95 S1/S1 40 458
P1 refers to the maximum power consumption. All of the data applies to 1~230 V, 50 Hz or 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Mechanical seal Sealing on motor side


P 13… NBR SiC/SiC Carbon/steatite

Equipment/function
Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
P 13… • - • • ǽ – - -
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 47
Wastewater transport
Submersible pumps for sewage DN 50 to DN 80

Dimensions Wilo-Rexa PRO V06..-21.. (2900 rpm)

Dimension drawing Wilo-Rexa PRO V06 - stationary wet well installation for DN 65

Ø26,9 x 2,0
172
150 54 148 > 325
57
100
15
185
145

175
150
200
DN65 32

585

385
19

S1 143
595
A

S2, S3
300

>65
206

160
75

>85

32

Dimension drawing Wilo-Rexa PRO V06 - stationary wet well installation for DN 80

Ø 42.4x2,0
100 120 97
150 59 166 > 325

200
170
220
200

152
DN80
15

51
815
615
19

S1
A

167
S2, S3 642

>65
300
256

210
125

>110

51

Dimension drawing Wilo-Rexa PRO V06 - stationary dry well installation

345
A

200
141

150
525

250
360
~260
100

48 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 50 to DN 80

Dimensions Wilo-Rexa PRO V06..-21.. (2900 rpm)

Dimension drawing Wilo-Rexa PRO V06 - transportable wet well installation


S1

Wastewater transport
A

150

S2, S3 DN 65/80
PN 16
266
211

300
155
70

330
Ø 300

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 49
Wastewater transport
Submersible pumps for sewage DN 50 to DN 80

Pump curves, technical data Wilo-Rexa PRO V06..-22.. (2900 rpm)

Pump curves Wilo-Rexa PRO V06..-22.. - 50 Hz - 2900 rpm


Vortex impeller - Free ball passage: 65 mm

H[m]

20
35%
37% 39%
18 41%
43%
45%
16

14 V06..-224

12

10 41%

39%
8
V06..-222
6

0
0 10 20 30 40 50 60 70 Q[m³/h]

0 4 8 12 16 20 Q[l/s]

P2[kW]
V06..-224 V06..-222

0
0 10 20 30 40 50 60 70 Q[m³/h]

0 4 8 12 16 20 Q[l/s]

Hydraulic data

Wilo-Rexa... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
PRO V06..-22.. 65 Vortex impeller 14
Pump curves apply to 1~230 V, 50 Hz or 3~400 V, 50 Hz, at nominal speed and a density of 1 kg/dm3. Pump curves according to ISO 9906, appendix A. The specified
degrees of efficiency correspond to the hydraulic efficiency.

50 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 50 to DN 80

Pump curves, technical data Wilo-Rexa PRO V06..-22.. (2900 rpm)

Motor data

Nominal Starting cur- Starting cur- Nominal Power Operating Motor Dimen-
current rent - direct rent - star- motor pow- consump- mode (im- weight sions
delta er tion mersed/non-

Wastewater transport
immersed)
IN IA P2 P1 A
A kW kg mm
S1/S2-30 min
P 13.1-10/EAD1X2-T 5.2 31 – 2.50 3.15 36 458
S3-25%
S1/S2-30 min
P 13.1-11/EAD3X2-T 5.1 31 – 2.50 3.05 36 458
S3-25%
S1/S2-30 min
P 13.1-15/EAD1X2-T 7.8 66 – 3.90 4.75 40 458
S3-25%
S1/S2-30 min
P 13.1-16/EAD3X2-T 7.8 66 – 3.90 4.60 40 458
S3-25%
P1 refers to the maximum power consumption. All of the data applies to 1~230 V, 50 Hz or 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Mechanical seal Sealing on motor side


P 13… NBR SiC/SiC Carbon/steatite

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
P 13… • - • • ǽ – - -
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 51
Wastewater transport
Submersible pumps for sewage DN 50 to DN 80

Dimensions Wilo-Rexa PRO V06..-22.. (2900 rpm)

Dimension drawing Wilo-Rexa PRO V06 - stationary wet well installation for DN 65

Ø26,9 x 2,0
172
150 54 148 > 325
57
100
15
185
145

175
150
200
DN65 32

585

385
19

S1 143
595
A

S2, S3
300

>65
206

160
75

>85

32

Dimension drawing Wilo-Rexa PRO V06 - stationary wet well installation for DN 80

Ø 42.4x2,0
100 120 97
150 59 166 > 325

200
170
220
200

152
DN80
15

51
815
615
19

S1
A

167
S2, S3 642

>65
300
256

210
125

>110

51

Dimension drawing Wilo-Rexa PRO V06 - stationary dry well installation

345
A

200
141

150
525

250
360
~260
100

52 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 50 to DN 80

Dimensions Wilo-Rexa PRO V06..-22.. (2900 rpm)

Dimension drawing Wilo-Rexa PRO V06 - transportable wet well installation


S1

Wastewater transport
A

150

S2, S3 DN 65/80
PN 16
266
211

300
155
70

330
Ø 300

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 53
Wastewater transport
Submersible pumps for sewage DN 50 to DN 80

Pump curves, technical data Wilo-Rexa PRO V06..-62.. (1450 rpm)

Pump curves Wilo-Rexa PRO V06..-62.. - 50 Hz - 1450 rpm


Vortex impeller - Free ball passage: 65 mm

H[m]

12
34%
40%
45%
48%
10
50%

4 34%
V06..-628
V06..-626
V06..-625
2

V06..-623
V06..-622
0
0 10 20 30 40 50 60 70 80 Q[m³/h]

0 4 8 12 16 20 Q[l/s]

P2[kW] V06..-628

2,0 V06..-626
1,5 V06..-625

V06..-623
1,0
V06..-622
0,5

0
0 10 20 30 40 50 60 70 80 Q[m³/h]

0 4 8 12 16 20 Q[l/s]

Hydraulic data

Wilo-Rexa... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
PRO V06..-62.. 65 Vortex impeller 20
Pump curves apply to 1~230 V, 50 Hz or 3~400 V, 50 Hz, at nominal speed and a density of 1 kg/dm3. Pump curves according to ISO 9906, appendix A. The specified
degrees of efficiency correspond to the hydraulic efficiency.

54 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 50 to DN 80

Pump curves, technical data Wilo-Rexa PRO V06..-62.. (1450 rpm)

Motor data

Nominal Starting cur- Starting cur- Nominal Power Operating Motor Dimen-
current rent - direct rent - star- motor pow- consump- mode (im- weight sions
delta er tion mersed/non-

Wastewater transport
immersed)
IN IA P2 P1 A
A kW kg mm
S1/S2-30 min
P 13.2-10/EAD1X4-T 3.05 24.5 – 1.10 1.46 40 460
S3-25%
S1/S2-30 min
P 13.2-10/EAD1X4-T 3.7 24.5 – 1.50 1.97 40 460
S3-25%
S1/S2-30 min
P 13.2-11/EAD0X4-M 7.3 25 – 1.10 1.57 41 460
S3-25%
S1/S2-30 min
P 13.2-11/EAD0X4-M 9.4 25 – 1.50 2.15 41 460
S3-25%
S1/S2-30 min
P 13.2-13/EAD1X4-T 5.8 35.5 – 2.50 3.25 42 460
S3-25%
S1/S2-30 min
P 13.2-16/EAD3X4-T 3.2 51 – 1.10 1.40 44 460
S3-25%
P 13.2-16/EAD3X4-T 3.3 51 – 1.25 1.55 S1/S1 44 460
S1/S2-30 min
P 13.2-16/EAD3X4-T 3.7 51 – 1.50 1.85 44 460
S3-25%
S1/S2-30 min
P 13.2-16/EAD0X4-T 8.1 51 – 3.45 4.45 44 460
S3-25%
P1 refers to the maximum power consumption. All of the data applies to 1~230 V, 50 Hz or 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Mechanical seal Sealing on motor side


P 13… NBR SiC/SiC Carbon/steatite

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
P 13… • - • • ǽ – - -
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 55
Wastewater transport
Submersible pumps for sewage DN 50 to DN 80

Dimensions Wilo-Rexa PRO V06..-62.. (1450 rpm)

Dimension drawing Wilo-Rexa PRO V06 - stationary wet well installation for DN 65

Ø26,9 x 2,0
180 54 148 > 325
172
147 57
15
185
145

175
263

150
DN65

385
648
32
19

143
S1 672
A

S2, S3
300

>65
225

160
65

>85

32

Dimension drawing Wilo-Rexa PRO V06 - stationary wet well installation for DN 80

Ø 42.4x2,0
147 120 97
180 59 166 > 325

200
170
220
263

152
DN80
15

51
878
615
19

S1
A

167
S2, S3 719

>65
300
275

210
115

>110

51

Dimension drawing Wilo-Rexa PRO V06 - stationary dry well installation

370
A

312
185

205
550

358
385
~275
110

56 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 50 to DN 80

Dimensions Wilo-Rexa PRO V06..-62.. (1450 rpm)

Dimension drawing Wilo-Rexa PRO V06 - transportable wet well installation


S1

Wastewater transport
A

150

S2, S3 DN 65/80
PN 16
287
230

300
165
70

330
Ø 300

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 57
Wastewater transport
Submersible pumps for sewage DN 50 to DN 80

Pump curves, technical data Wilo-Rexa PRO V08..-42.. (1450 rpm)

Pump curves Wilo-Rexa PRO V08..-42.. - 50 Hz - 1450 rpm


Vortex impeller - Free ball passage: 80 mm

H[m]

10
35%
40%
9 45%
49%
51%
8
53%

4 40%
V08..-428
3
V08..-426
V08..-423 V08..-424
2

0
0 10 20 30 40 50 60 70 80 90 Q[m³/h]

0 4 8 12 16 20 24 Q[l/s]

P2[kW]
V08..-428

1,5 V08..-426

1,0 V08..-423
V08..-424

0,5

0
0 10 20 30 40 50 60 70 80 90 Q[m³/h]

0 4 8 12 16 20 24 Q[l/s]

Hydraulic data

Wilo-Rexa... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
PRO V08..-42.. 80 Vortex impeller 28
Pump curves apply to 1~230 V, 50 Hz or 3~400 V, 50 Hz, at nominal speed and a density of 1 kg/dm3. Pump curves according to ISO 9906, appendix A. The specified
degrees of efficiency correspond to the hydraulic efficiency.

58 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 50 to DN 80

Pump curves, technical data Wilo-Rexa PRO V08..-42.. (1450 rpm)

Motor data

Nominal Starting cur- Starting cur- Nominal Power Operating Motor Dimen-
current rent - direct rent - star- motor pow- consump- mode (im- weight sions
delta er tion mersed/non-

Wastewater transport
immersed)
IN IA P2 P1 A
A kW kg mm
S1/S2-30 min
P 13.2-10/EAD1X4-T 3.05 24.5 – 1.10 1.46 40 460
S3-25%
S1/S2-30 min
P 13.2-10/EAD1X4-T 3.7 24.5 – 1.50 1.97 40 460
S3-25%
S1/S2-30 min
P 13.2-11/EAD0X4-M 7.3 25 – 1.10 1.57 41 460
S3-25%
S1/S2-30 min
P 13.2-11/EAD0X4-M 9.4 25 – 1.50 2.15 41 460
S3-25%
S1/S2-30 min
P 13.2-13/EAD1X4-T 5.8 35.5 – 2.50 3.25 42 460
S3-25%
S1/S2-30 min
P 13.2-16/EAD3X4-T 3.2 51 – 1.10 1.40 44 460
S3-25%
P 13.2-16/EAD3X4-T 3.3 51 – 1.25 1.55 S1/S1 44 460
S1/S2-30 min
P 13.2-16/EAD3X4-T 3.7 51 – 1.50 1.85 44 460
S3-25%
P1 refers to the maximum power consumption. All of the data applies to 1~230 V, 50 Hz or 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Mechanical seal Sealing on motor side


P 13… NBR SiC/SiC Carbon/steatite

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
P 13… • - • • ǽ – - -
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 59
Wastewater transport
Submersible pumps for sewage DN 50 to DN 80

Dimensions Wilo-Rexa PRO V08..-42.. (1450 rpm)

Dimension drawing Wilo-Rexa PRO V08 - stationary wet well installation

Ø 42.4x2,0
195 59 166 > 325 148 120 97

220
170
200

288
152
DN80

15
51

903
615
19

S1
A

167
S2, S3
642
>80
285

300
210
105

>110

51

Dimension drawing Wilo-Rexa PRO V08 - stationary dry well installation

370
A

288
180

195
550

343
385
~275
110

Dimension drawing Wilo-Rexa PRO V08 - transportable wet well installation

S1
A

195
S2, S3
361
304

288
229
124

343
ø 344

60 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 50 to DN 80

Pump curves, technical data Wilo-Rexa PRO V08..-52.. (1450 rpm)

Pump curves Wilo-Rexa PRO V08..-52.. - 50 Hz - 1450 rpm


Vortex impeller - Free ball passage: 80 mm

H[m]

Wastewater transport
40%
12
45%
49%
52%
54%
10

V08..-526
52%
8
49%

45%
6
V08..-524

4
V08..-522

0
0 20 40 60 80 100 Q[m³/h]

0 4 8 12 16 20 24 28 Q[l/s]
V08..-526
P2[kW] V08..-524
3

V08..-522
2

0
0 20 40 60 80 100 Q[m³/h]

0 4 8 12 16 20 24 28 Q[l/s]

Hydraulic data

Wilo-Rexa... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
PRO V08..-52.. 80 Vortex impeller 29
Pump curves apply to 1~230 V, 50 Hz or 3~400 V, 50 Hz, at nominal speed and a density of 1 kg/dm3. Pump curves according to ISO 9906, appendix A. The specified
degrees of efficiency correspond to the hydraulic efficiency.

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 61
Wastewater transport
Submersible pumps for sewage DN 50 to DN 80

Pump curves, technical data Wilo-Rexa PRO V08..-52.. (1450 rpm)

Motor data

Nominal Starting cur- Starting cur- Nominal Power Operating Motor Dimen-
current rent - direct rent - star- motor pow- consump- mode (im- weight sions
delta er tion mersed/non-
immersed)
IN IA P2 P1 A
A kW kg mm
S1/S2-30 min
P 13.2-13/EAD1X4-T 5.8 35.5 – 2.50 3.25 42 460
S3-25%
S1/S2-30 min
P 13.2-16/EAD0X4-T 8.1 51 – 3.45 4.45 44 460
S3-25%
P1 refers to the maximum power consumption. All of the data applies to 1~230 V, 50 Hz or 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Mechanical seal Sealing on motor side


P 13… NBR SiC/SiC Carbon/steatite

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
P 13… • - • • ǽ – - -
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

62 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 50 to DN 80

Dimensions Wilo-Rexa PRO V08..-52.. (1450 rpm)

Dimension drawing Wilo-Rexa PRO V08 - stationary wet well installation

Ø 42.4x2,0
153 120 97

Wastewater transport
205 59 166 > 325

200

312

220
170
152
DN80

15
927
51

615
19

S1
A

167
S2, S3 719
>80
285

300
210
100

>110

51

Dimension drawing Wilo-Rexa PRO V08 - stationary dry well installation

370
A

312
185

205
550

358
385
~275
110

Dimension drawing Wilo-Rexa PRO V08 - transportable wet well installation

S1
A

205
S2, S3
366
309

312
234
124

358
ø 344

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 63
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Series description Wilo-EMU FA 08... - 15...

Wilo-EMU FA 08... - 15...

y{}
Design • Surfaced operating mode with self-cooling motor: S1
Submersible sewage pump with dry motors or self-cooling motors • Protection class: IP 68
• Max. fluid temperature: 3 - 40 °C, higher temperatures on request
Type key • Sealing: With rotary shaft seal and mechanical seal, two mechanical
seals or one block seal cartridge, depending on the motor
Example Wilo-EMU FA 08.34E + T 17.2-4/24K Ex • Free ball passage: 45 - 130 mm.
Hydraulics: FA 08.34E • Permanently lubricated roller bearings
• Max. immersion depth: 20 m
FA Submersible sewage pump
08 x10 = nominal diameter of the pressure port, e.g. DN80 Materials
34 Performance indicator • Housing parts: EN-GJL or EN-GJS
• Impeller: EN-GJL or EN-GJS
E Type of impeller
• Static seals: NBR or FKM
• Sealing on pump side: SiC/SiC
Motor: T 17.2-4/24K Ex • Sealing on motor side: NBR or SiC/SiC
• Shaft: Stainless steel 1.4021
T Motor version
17 Size Equipment/function
2 Distinctive number • Heavy-duty version made of grey cast iron
• Self-cooling motors with 1- or 2-chamber system
4 Number of poles • Simple installation via suspension unit or pump base
24 x10 = package length [mm]
K Sealing version Description/design
Submersible sewage pump as submersible monobloc unit for station-
Ex Ex-rated ary and portable wet well and dry well installation. Portable installa-
tion is possible, depending on type.
Application
• Pumping of sewage with solid constituents in water treatment sys- Hydraulics
tems and pumping stations The outlet on the pressure side is designed as horizontal flange con-
• Local drainage, water control and process water extraction nection. The maximum possible dry matter content is 8%, depending
• Applications in construction and industry on the hydraulics and impeller type.

Special features/product advantages The following impeller shapes are used:


• Operation in stationary and portable wet well and dry well installation • Vortex impeller (W)
• Submersible • Single-channel impeller (E)
• Easy installation due to suspension unit or pump base • Two-channel impeller (Z)
• Special materials and coatings against abrasion and corrosion • Three-channel impeller (D)
• Longitudinally watertight cable lead-in (depending on motor)
• Adjustment of duty point by trimming the impeller The single and multi-channel hydraulics (Z, D) are equipped with a
mobile and stationary wear ring (depending on type). These contrib-
ute long-term to ensuring the uniform efficiency of the unit.
Technical data
• Mains connection: 3~400 V, 50 Hz
• Immersed operating mode: S1

64 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Series description Wilo-EMU FA 08... - 15...

Motor • Monitoring units for leakage and bearing temperature


Dry motors (T motors) give off their heat directly to the surrounding • Special materials, e.g. Abrasite
fluid via the housing components and can be used in immersed state • Ceram coating C0, C1, C2, C3
for permanent operation. Depending on the size, they can also be • Ex-rated to ATEX or FM

Wastewater transport
used in non-immersed state for short-term or permanent operation.
Scope of delivery
The oil-filled motors (FK motors) and self-cooling dry motors (FKT, • Submersible sewage pump
HC motors) give off their heat to the pumped fluid via a built-in heat • Cable length up to motor size 17 available in increments of 10 m,
exchanger. Therefore, these motors are suitable for permanent oper- from motor size 20 and higher according to customer request
ation in immersed and non-immersed condition or for dry well instal- • Accessories according to customer request
lation. • Operating and maintenance manual
All motors have a sealing chamber that protects the motor from fluid
Accessories
ingress. It can be accessed from the outside and can be monitored
with an optional sealing chamber electrode.
• Suspension unit or pump base
• Various pressure outlets and Storz couplings
All filling fluids used are potentially biodegradable and environmen-
• Chains
tally safe.
• Fixation sets with anchor bolts
• Switchgears, relays and plugs
The cable inlet on T, HC and FKT motors is longitudinally watertight.
Up to motor size 17, cable lengths are available in fixed lengths Commissioning
measured in 10 m intervals. Starting from motor size 20, the cable Operation in wet well installation with non-immersed motor
length can be individually configured. The surfacing of self-cooling motors (FK, FKT, HC motors) is permit-
ted.
Sealing
Fluid-side and motor-side sealing is possible in the following ver- In dry motors (T-motor), it is possible to have the motor non-im-
sions depending on the motor type: mersed for short periods if equipped with motor temperature moni-
• Version H: Mechanical seal for the fluid side, rotary shaft seal for the toring with a temperature circuit, or with two temperature circuits
motor side when used in potentially explosive areas. The maximum running time
• Version G: Two independently operating mechanical seals with non-immersed motor depends on the medium and ambient
• Version K: Block seal cartridge with two independently operating me- temperatures. Therefore, it is not possible to provide exact informa-
chanical seals tion about the operating mode and time (e.g. S2-15)!

Dry-running protection
Options
The hydraulic housing must always be immersed to prevent air from
• Special voltages being drawn in. In the case of fluctuating fluid levels, the system
• PTC thermistor sensor should shut down automatically once the minimum water submer-
• Internal or external sealing chamber control sion is reached.

H/m Wilo-EMU FA...


DN80 ... DN150
100

70
60 DN 100
50
40
30

20
DN 80 DN 150

10

1
1 10 100 200 300 500 1000 Q/l/s

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 65
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 08.34E (2900 rpm)

Pump curves Wilo-EMU FA 08.34E - 50 Hz - 2900 rpm


Single-channel impeller - Free ball passage: 45 mm

H[m]

28 40%
50%
58%
24
64%
68%

20
Ø 150

16
Ø 145

12 Ø 140
Ø 135

8 Ø 130

40% Ø 125
4
Ø 120
Ø 105 Ø 110 Ø 115
0
0 10 20 30 40 50 60 70 80 90 Q[m³/h]

0 4 8 12 16 20 24 Q[l/s]

P2[kW]

4 Ø 150 Ø 145
Ø 140
3 Ø 135 Ø 130
Ø 125
2 Ø 120
Ø 115
Ø 105 Ø 110
1

0
0 10 20 30 40 50 60 70 80 90 Q[m³/h]

0 4 8 12 16 20 24 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 08.34E 45 Single-channel impeller 16
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

66 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 08.34E (2900 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-

Wastewater transport
immersed)
IN IA P2 P1 A AW
A kW kg mm
T 13-2/9 (Ex) 3.8 25 9 1.60 2.05 S1/S1 37 394 319
T 13-2/9 (Ex) 5.3 25 9 2.40 3.00 S1/S2-15 min 37 394 319
T 13-2/12 (Ex) 5 37 13 2.20 2.80 S1/S2-15 min 39 394 319
T 13-2/12 (Ex) 7.6 37 13 3.75 4.70 S1/S2-15 min 39 394 319
T 13-2/16 (Ex) 9.7 64 22 5.00 5.90 S1/S2-15 min 42.5 449 374
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
T 13... FPM FPM, SiC/SiC - SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
T 13... ǽ ǽ • • ǽ – - -
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 67
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Dimensions Wilo-EMU FA 08.34E (2900 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

625
324

90/98

ø42,4x2
120
90 69
AW

166
59

110

170
15
50
40

50
1
77 39

300
249

210

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

125
230

1
3

150
265
245

1
394
2

110

315

Dimension drawing Wilo-EMU FA - portable installation

165
2

555
75
125
230

1
3

437
366

453
150
411

100
265
388
240

201
124

Ø 344

1 = DN80 PN10 / ANSI B16.1, Class 125, Size 3; 2 = DN80 PN10; 3 = DN65 PN10 / ANSI B16.1, Class 125, Size 2,5

68 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 08.41E (1450 rpm)

Pump curves Wilo-EMU FA 08.41E - 50 Hz - 1450 rpm


Single-channel impeller - Free ball passage: 65 mm

H[m]

Wastewater transport
7

3
Ø 144

2
Ø 130

0
0 10 20 30 40 50 60 70 Q[m³/h]

0 4 8 12 16 20 Q[l/s]

P2[kW] Ø 144

0,8
Ø 130
0,6

0,4

0,2

0
0 10 20 30 40 50 60 70 Q[m³/h]

0 4 8 12 16 20 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 08.41E 65 Single-channel impeller 13
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 69
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 08.41E (1450 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-
immersed)
IN IA P2 P1 A AW
A kW kg mm
T 12-4/11 (Ex) 3.3 16 6 1.30 1.74 S1/S2-15 min 25 379 319
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
T 12... FPM - SiC/SiC, SiC/SiC -

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
T 12... ǽ ǽ • • ǽ – - -
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

70 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Dimensions Wilo-EMU FA 08.41E (1450 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

625
329

Wastewater transport
90/98

ø42,4x2
120
90 69
AW

166
59

110

170
15
50
40

50
1
76 53

300
263

210

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

126
239

150
244

2 270
407
2

110

315

Dimension drawing Wilo-EMU FA - portable installation

165
2

555
75
126
239

437
362

453
150
407

100
270
384
250

197
124

Ø 344

1 = DN80 PN10 / ANSI B16.1, Class 125, Size 3; 2 = DN80 PN10

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 71
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 08.41E (2900 rpm)

Pump curves Wilo-EMU FA 08.41E - 50 Hz - 0.0 rpm


Single-channel impeller - Free ball passage: 65 mm

H[m]

16

14
30%
40%
50%
12
56%
60%
10

Ø 114
50%
4
Ø 110
Ø 106
Ø 102
2

0
0 20 40 60 80 100 Q[m³/h]

0 4 8 12 16 20 24 28 Q[l/s]

P2[kW]

Ø 114
2,0
Ø 110
1,5 Ø 106
Ø 102
1,0

0,5

0
0 20 40 60 80 100 Q[m³/h]

0 4 8 12 16 20 24 28 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 08.41E 65 Single-channel impeller 13
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

72 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 08.41E (2900 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-

Wastewater transport
immersed)
IN IA P2 P1 A AW
A kW kg mm
T 12-2/11 (Ex) 3.65 25 9 1.50 2.00 S1/S2-30 min 25 379 319
T 12-2/11 (Ex) 4.45 25 9 2.00 2.60 S1/S2-15 min 25 379 319
T 12-2/11 (Ex) 4.8 25 9 2.25 2.90 S1/– 25 379 319
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
T 12... FPM - SiC/SiC, SiC/SiC -

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
T 12... ǽ ǽ • • ǽ – - -
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 73
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Dimensions Wilo-EMU FA 08.41E (2900 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

625
329

90/98

ø42,4x2
120
90 69
AW

166
59

110

170
15
50
40

50
1
76 53

300
263

210

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

126
239

150
244

2 270
407
2

110

315

Dimension drawing Wilo-EMU FA - portable installation

165
2

555
75
126
239

437
362

453
150
407

100
270
384
250

197
124

Ø 344

1 = DN80 PN10 / ANSI B16.1, Class 125, Size 3; 2 = DN80 PN10

74 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 08.43E (2900 rpm)

Pump curves Wilo-EMU FA 08.43E - 50 Hz - 2900 rpm


Single-channel impeller - Free ball passage: 70 mm

H[m]

Wastewater transport
32
20%

40%
28
50%
60%
65%
24
Ø 150
70%
20
Ø 145

16
Ø 140

12 Ø 135

Ø 130
8
50%
Ø 125
4 40%
Ø 120
Ø 110 Ø 115

0
0 20 40 60 80 100 120 Q[m³/h]

0 5 10 15 20 25 30 35 Q[l/s]

P2[kW] Ø 150
Ø 145
Ø 140 Ø 135
4
Ø 130
3 Ø 125
Ø 120
2 Ø 115
Ø 110
1

0
0 20 40 60 80 100 120 Q[m³/h]

0 5 10 15 20 25 30 35 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 08.43E 70 Single-channel impeller 17
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 75
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 08.43E (2900 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-
immersed)
IN IA P2 P1 A AW
A kW kg mm
T 13-2/9 (Ex) 3.8 25 9 1.60 2.05 S1/S1 37 394 319
T 13-2/9 (Ex) 5.3 25 9 2.40 3.00 S1/S2-15 min 37 394 319
T 13-2/12 (Ex) 5 37 13 2.20 2.80 S1/S2-15 min 39 394 319
T 13-2/12 (Ex) 7.6 37 13 3.75 4.70 S1/S2-15 min 39 394 319
T 13-2/16 (Ex) 9.7 64 22 5.00 5.90 S1/S2-15 min 42.5 449 374
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
T 13... FPM FPM, SiC/SiC - SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
T 13... ǽ ǽ • • ǽ – - -
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

76 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Dimensions Wilo-EMU FA 08.43E (2900 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

625
329

Wastewater transport
90/98

ø42,4x2 120
90 69
AW

166

110

170
15
50
59

50
40
1
91 54

300
264

210

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

126
239

150
259

1 269
423
2

110

315

Dimension drawing Wilo-EMU FA - portable installation

165
2

555
75
126
239

437
2
380

453
425

100 150
269
402
269

215
124

Ø 344

1 = DN80 PN10 / ANSI B16.1, Class 125, Size 3; 2 = DN80 PN10

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 77
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 08.52W (1450 rpm)

Pump curves Wilo-EMU FA 08.52W - 50 Hz - 1450 rpm


Vortex impeller - Free ball passage: 80 mm

H[m]
18
30%
40%
16
45%

14

12

10

8
40%

6
Ø 200 30%

4
Ø 260
Ø 215
2 Ø 170 Ø 185 Ø 230

0
0 20 40 60 80 100 120 140 Q[m³/h]

0 5 10 15 20 25 30 35 40 Q[l/s]

P2[kW]

6
Ø 260

4
Ø 200 Ø 230
Ø 215
2 Ø 170 Ø 185

0
0 20 40 60 80 100 120 140 Q[m³/h]

0 5 10 15 20 25 30 35 40 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 08.52W 80 Vortex impeller 33
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

78 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 08.52W (1450 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-

Wastewater transport
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 17.1-4/8 (Ex) 5.7 36.5 12 2.20 3.05 S1/S1 85 640 430
FK 17.1-4/8 (Ex) 9.5 36 12 4.00 5.50 S1/S1 85 640 430
FK 17.1-4/12 (Ex) 10.8 43 14 5.00 6.50 S1/S1 92 640 430
FK 17.1-4/16 (Ex) 14.1 69 23 6.60 8.40 S1/S1 107 760 550
T 17-4/8 (Ex) 7.9 37 13 3.50 4.50 S1/– 43 410 338
T 17-4/12 (Ex) 9.4 47 16 4.50 5.80 S1/– 51 445 373
T 17-4/16 (Ex) 13.5 68 23 6.50 8.20 S1/– 62 483 411
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 17.1... FPM - - SiC/SiC, SiC/SiC
T 17... FPM FPM, SiC/SiC - SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 17.1... ǽ ǽ • – ǽ – - -
T 17... ǽ ǽ • • • – - -
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 79
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Dimensions Wilo-EMU FA 08.52W (1450 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

625
433

90/98

120
ø42,4x2
90 69
AW

166

110

170
15
50
59

50
40
1
100 90

300
300

210

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

170
340

200
374
268

2
468
2

110

365

Dimension drawing Wilo-EMU FA - portable installation

165
2

642
75
170
340

524
389

540
200
434

100
374
411
314

224
124

Ø 344

1 = DN80 PN10 / ANSI B16.1, Class 125, Size 3; 2 = DN80 PN10

80 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 08.53E (1450 rpm)

Pump curves Wilo-EMU FA 08.53E - 50 Hz - 1450 rpm


Single-channel impeller - Free ball passage: 70 mm

H[m]

Wastewater transport
16 30%
40%
50%
14
58%
62%
12

10

8
Ø 215
6
Ø 200
50%

4 Ø 185

Ø 170
2

0
0 20 40 60 80 100 120 Q[m³/h]

0 5 10 15 20 25 30 35 Q[l/s]

P2[kW]
Ø 215

3 Ø 200

Ø 185
2
Ø 170
1

0
0 20 40 60 80 100 120 Q[m³/h]

0 5 10 15 20 25 30 35 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 08.53E 70 Single-channel impeller 30
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 81
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 08.53E (1450 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 17.1-4/8 (Ex) 5.7 36.5 12 2.20 3.05 S1/S1 85 640 430
FK 17.1-4/8 (Ex) 9.5 36 12 4.00 5.50 S1/S1 85 640 430
FK 17.1-4/12 (Ex) 10.8 43 14 5.00 6.50 S1/S1 92 640 430
T 13-4/9 (Ex) 4.2 16 6 1.75 2.50 S1/S2-15 min 37 394 319
T 13-4/12 (Ex) 5.1 20 7 2.25 3.00 S1/S2-15 min 39 394 319
T 13-4/18 (Ex) 9.2 32 11 4.00 5.00 S1/S2-15 min 43.5 449 374
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 17.1... FPM - - SiC/SiC, SiC/SiC
T 13... FPM FPM, SiC/SiC - SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 17.1... ǽ ǽ • – ǽ – - -
T 13... ǽ ǽ • • ǽ – - -
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

82 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Dimensions Wilo-EMU FA 08.53E (1450 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

625
490

Wastewater transport
90/98

ø42,4x2 120
90 69
AW

166

110

170
15
50
59

50
40
1
95 62

300
272

210

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

206
381

240
431
262

2
434
2

110

405

Dimension drawing Wilo-EMU FA - portable installation

165
2

699
75
206
381

581
384

597
240
429

100
431
406
281

219
126

Ø 344

1 = DN80 PN10 / ANSI B16.1, Class 125, Size 3; 2 = DN80 PN10

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 83
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 08.64E (1450 rpm)

Pump curves Wilo-EMU FA 08.64E - 50 Hz - 1450 rpm


Single-channel impeller - Free ball passage: 80 mm

H[m]

28
50%
60% 64%
24
66%

20

Ø 278
64%
16

60% Ø 270
12
Ø 258
Ø 246
8
Ø 234

0
0 20 40 60 80 100 120 140 160 180 Q[m³/h]

0 10 20 30 40 50 Q[l/s]

P2[kW]

Ø 278 Ø 270
8 Ø 258
Ø 246
6 Ø 234

0
0 20 40 60 80 100 120 140 160 180 Q[m³/h]

0 10 20 30 40 50 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 08.64E 80 Single-channel impeller 47
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

84 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 08.64E (1450 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-

Wastewater transport
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 17.1-4/8 (Ex) 9.5 36 12 4.00 5.50 S1/S1 85 640 430
FK 17.1-4/12 (Ex) 10.8 43 14 5.00 6.50 S1/S1 92 640 430
FK 17.1-4/16 (Ex) 14.1 69 23 6.60 8.40 S1/S1 107 760 550
FK 202-4/12 16.6 67 23 7.80 9.90 S1/S1 106 726 619
FK 202-4/17 24.5 98 33 11.50 14.60 S1/S1 119 771 664
HC 20.1-4/17 (Ex) 21 99 33 10.00 12.10 S1/S1 172 835 730
T 17-4/8 (Ex) 7.9 37 13 3.50 4.50 S1/– 43 410 338
T 17-4/12 (Ex) 9.4 47 16 4.50 5.80 S1/– 51 445 373
T 17-4/16 (Ex) 13.5 68 23 6.50 8.20 S1/– 62 483 411
T 17.2-4/24 (Ex) 21 123 41 10.00 12.20 S1/– 91 582 510
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 17.1... FPM - - SiC/SiC, SiC/SiC
FK 202... NBR - - SiC/SiC, SiC/SiC
HC 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC
T 17... FPM FPM, SiC/SiC - SiC/SiC, SiC/SiC
T 17.2... NBR NBR, SiC/SiC - SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 17.1... ǽ ǽ • – ǽ – - -
FK 202... - - • ǽ ǽ – - -
HC 20.1... ǽ ǽ • • ǽ • - •
T 17... ǽ ǽ • • • – - -
T 17.2... ǽ ǽ • • • – - -
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 85
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Dimensions Wilo-EMU FA 08.64E (1450 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

625
504

90/98

ø42,4x2 120
90 69
AW

166

110

170
15
50
59
40

50
1
100 76

300
286

210

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

211
407

245
282

3
483

445
4

125

425

Dimension drawing Wilo-EMU FA - portable installation

165
2

713
75
211
407

595
389

611
245
434

100
445
411
300

224
124

Ø 344

1 = DN80 PN10 / ANSI B16.1, Class 125, Size 3; 2 = DN80 PN10; 3 = DN100 PN10 / ANSI B16.1, Class 125, Size 4; 4 = DN100 PN10

86 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 08.66W (2900 rpm)

Pump curves Wilo-EMU FA 08.66W - 50 Hz - 2900 rpm


Vortex impeller - Free ball passage: 50 mm

Wastewater transport
H[m]

20%
60
30%
35%
Ø 240

50 40%

Ø 225
40
42%

30
Ø 210

20 Ø 195

Ø 180

10 Ø 165

Ø 150

0
0 20 40 60 80 100 120 140 Q[m³/h]

0 5 10 15 20 25 30 35 40 Q[l/s]

P2[kW]
Ø 240
Ø 225 Ø 210
15 Ø 195
Ø 180
10 Ø 165
Ø 150
5

0
0 20 40 60 80 100 120 140 Q[m³/h]

0 5 10 15 20 25 30 35 40 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 08.66W 50 Vortex impeller 27
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 87
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 08.66W (2900 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 202-2/17 25 115 38 11.50 15.20 S1/S1 119 771 664
FK 202-2/22 34.5 160 53 17.00 21.00 S1/S1 138 821 714
HC 20.1-2/17 (Ex) 22.5 115 38 11.00 13.80 S1/S1 172 835 730
HC 20.1-2/22 (Ex) 30 160 54 15.50 18.60 S1/S1 188 935 830
HC 20.1-2/30 (Ex) 44.5 220 74 23.00 27.50 S1/S1 204 935 830
T 17-2/22 (Ex) 20.5 171 57 10.50 12.30 S1/– 91 563 491
T 20.1-2/22 (Ex) 30 215 71 15.50 18.60 S1/S2-15 min 168 764 674
T 20.1-2/30 (Ex) 45.5 325 52 23.00 28.00 S1/S2-15 min 182 764 674
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 202... NBR - - SiC/SiC, SiC/SiC
HC 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC
T 17... FPM FPM, SiC/SiC - SiC/SiC, SiC/SiC
T 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 202... - - • ǽ ǽ – - -
HC 20.1... ǽ ǽ • • ǽ • - •
T 17... ǽ ǽ • • • – - -
T 20.1... ǽ ǽ • • ǽ • - •
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

88 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Dimensions Wilo-EMU FA 08.66W (2900 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

625

Wastewater transport
464

90/98

ø42,4x2 120
90 69
AW

166

110

170
15
50
59

50
40
1
85 62

300
272

210

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

175
350

230
405
253

1
425
2

110

395

Dimension drawing Wilo-EMU FA - portable installation

165
2

673
75
175
350

555
374

571
419

100 230
405
396
271

209
124

Ø 344

1 = DN80 PN10 / ANSI B16.1, Class 125, Size 3; 2 = DN80 PN10

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 89
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 08.73W (1450 rpm)

Pump curves Wilo-EMU FA 08.73W - 50 Hz - 1450 rpm


Vortex impeller - Free ball passage: 80 mm

H[m]

20%
20
30%

18
40%

16

14 43%

43% 40%
12

10 Ø 260
Ø 250
8

6
Ø 225
4

0
0 20 40 60 80 100 120 Q[m³/h]

0 5 10 15 20 25 30 35 Q[l/s]

P2[kW]
Ø 260
8 Ø 250

6 Ø 225

0
0 20 40 60 80 100 120 Q[m³/h]

0 5 10 15 20 25 30 35 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 08.73W 80 Vortex impeller 33
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

90 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 08.73W (1450 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-

Wastewater transport
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 17.1-4/8 (Ex) 9.5 36 12 4.00 5.50 S1/S1 85 640 430
FK 17.1-4/12 (Ex) 10.8 43 14 5.00 6.50 S1/S1 92 640 430
FK 17.1-4/16 (Ex) 14.1 69 23 6.60 8.40 S1/S1 107 760 550
FK 202-4/12 16.6 67 23 7.80 9.90 S1/S1 106 726 619
FK 202-4/17 24.5 98 33 11.50 14.60 S1/S1 119 771 664
HC 20.1-4/17 (Ex) 21 99 33 10.00 12.10 S1/S1 172 835 730
HC 20.1-4/22 (Ex) 31 126 42 15.00 18.10 S1/S1 188 935 830
T 17-4/12 (Ex) 9.4 47 16 4.50 5.80 S1/– 51 445 373
T 17-4/16 (Ex) 13.5 68 23 6.50 8.20 S1/– 62 483 411
T 17-4/24 (Ex) 21 123 41 10.00 12.20 S1/– 91 563 491
T 20.1-4/22 (Ex) 30.5 156 52 15.00 18.10 S1/S2-15 min 168 764 674
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 17.1... FPM - - SiC/SiC, SiC/SiC
FK 202... NBR - - SiC/SiC, SiC/SiC
HC 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC
T 17... FPM FPM, SiC/SiC - SiC/SiC, SiC/SiC
T 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 17.1... ǽ ǽ • – ǽ – - -
FK 202... - - • ǽ ǽ – - -
HC 20.1... ǽ ǽ • • ǽ • - •
T 17... ǽ ǽ • • • – - -
T 20.1... ǽ ǽ • • ǽ • - •
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 91
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Dimensions Wilo-EMU FA 08.73W (1450 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

625
433

90/98

ø42,4x2 120
90 69
AW

166

110

170
15
50
59

50
40
1
101 90

300
300

210

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

170
340

200
268

2 374
468
2

110

374

Dimension drawing Wilo-EMU FA - portable installation

165
2

642
75
170
340

524
389

540
434

100 200
374
411
314

224
124

Ø 344

1 = DN80 PN10 / ANSI B16.1, Class 125, Size 3; 2 = DN80 PN10

92 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 08.73W (2900 rpm)

Pump curves Wilo-EMU FA 08.73W - 50 Hz - 2900 rpm


Vortex impeller - Free ball passage: 80 mm

H[m]

Wastewater transport
50
30%
35%
40%
45

Ø 200
40
Ø 190
45%
35
Ø 180
30

25
Ø 170
20 40%

Ø 160
15 35%

10
Ø 150
5

0
0 20 40 60 80 100 120 140 Q[m³/h]

0 5 10 15 20 25 30 35 40 Q[l/s]

P2[kW]

Ø 200
Ø 190 Ø 180 Ø 170 Ø 160 Ø 150
15

10

0
0 20 40 60 80 100 120 140 Q[m³/h]

0 5 10 15 20 25 30 35 40 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 08.73W 80 Vortex impeller 33
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 93
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 08.73W (2900 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 202-2/17 25 115 38 11.50 15.20 S1/S1 119 771 664
FK 202-2/22 34.5 160 53 17.00 21.00 S1/S1 138 821 714
HC 20.1-2/17 (Ex) 22.5 115 38 11.00 13.80 S1/S1 172 835 730
HC 20.1-2/22 (Ex) 30 160 54 15.50 18.60 S1/S1 188 935 830
HC 20.1-2/30 (Ex) 44.5 220 74 23.00 27.50 S1/S1 204 935 830
T 17-2/22 (Ex) 20.5 171 57 10.50 12.30 S1/– 91 563 491
T 20.1-2/22 (Ex) 30 215 71 15.50 18.60 S1/S2-15 min 168 764 674
T 20.1-2/30 (Ex) 45.5 325 52 23.00 28.00 S1/S2-15 min 182 764 674
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 202... NBR - - SiC/SiC, SiC/SiC
HC 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC
T 17... FPM FPM, SiC/SiC - SiC/SiC, SiC/SiC
T 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 202... - - • ǽ ǽ – - -
HC 20.1... ǽ ǽ • • ǽ • - •
T 17... ǽ ǽ • • • – - -
T 20.1... ǽ ǽ • • ǽ • - •
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

94 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Dimensions Wilo-EMU FA 08.73W (2900 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

625
433

Wastewater transport
90/98

ø42,4x2 120
90 69
AW

166

110

170
15
50
59

50
40
1
101 90

300
300

210

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

170
340

200
268

2 374
468
2

110

374

Dimension drawing Wilo-EMU FA - portable installation

165
2

642
75
170
340

524
389

540
434

100 200
374
411
314

224
124

Ø 344

1 = DN80 PN10 / ANSI B16.1, Class 125, Size 3; 2 = DN80 PN10

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 95
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 10.22W (950 rpm)

Pump curves Wilo-EMU FA 10.22W - 50 Hz - 950 rpm


Vortex impeller - Free ball passage: 100 mm

H[m]

30%
40%
7
45%

6 49%

3
40%

2
Ø 185 Ø 200 Ø 260
Ø 170
Ø 230
1

0
0 20 40 60 80 100 Q[m³/h]

0 4 8 12 16 20 24 28 Q[l/s]

P2[kW]

Ø 260
1,2

Ø 200 Ø 230
0,8
Ø 185
Ø 170
0,4

0
0 20 40 60 80 100 Q[m³/h]

0 4 8 12 16 20 24 28 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 10.22W 100 Vortex impeller 35
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

96 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 10.22W (950 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-

Wastewater transport
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 17.1-6/8 (Ex) 5.2 17 6 1.80 2.80 S1/S1 85 640 430
FK 17.1-6/12 (Ex) 7.5 29 10 3.10 4.20 S1/S1 92 640 430
T 17-6/8 (Ex) 4.45 17 6 1.75 2.50 S1/– 43 410 338
T 17-6/12 (Ex) 6.2 31 11 2.50 3.45 S1/– 51 445 373
T 17-6/16 (Ex) 9.1 39 13 3.70 5.20 S1/– 62 483 411
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 17.1... FPM - - SiC/SiC, SiC/SiC
T 17... FPM FPM, SiC/SiC - SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 17.1... ǽ ǽ • – ǽ – - -
T 17... ǽ ǽ • • • – - -
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 97
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Dimensions Wilo-EMU FA 10.22W (950 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

800
439

90/ 96

160
ø42,4x2 90 109
AW

110

190
176

15
65

50

50
44
1
92

325
117
317

225

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

170
340

200
298
515

1 374
2

125

380

Dimension drawing Wilo-EMU FA - portable installation

180
2

667
100
170

553
419
489

340

588
120
200
374
440
329

239
124

Ø 344

1 = DN100 PN10 / ANSI B16.1, Class 125, Size 4; 2 = DN100 PN10

98 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 10.22W (1450 rpm)

Pump curves Wilo-EMU FA 10.22W - 50 Hz - 1450 rpm


Vortex impeller - Free ball passage: 100 mm

H[m]

Wastewater transport
18
30%
39% 43%
16

48%
14

12
Ø 260

10

Ø 230
6
Ø 200
4
Ø 170 Ø 185

0
0 10 20 30 40 50 60 70 80 90 Q[m³/h]

0 4 8 12 16 20 24 Q[l/s]

P2[kW]

6 Ø 260

4
Ø 230
Ø 200
2 Ø 185
Ø 170

0
0 10 20 30 40 50 60 70 80 90 Q[m³/h]

0 4 8 12 16 20 24 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 10.22W 100 Vortex impeller 35
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 99
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 10.22W (1450 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 17.1-4/8 (Ex) 5.7 36.5 12 2.20 3.05 S1/S1 85 640 430
FK 17.1-4/8 (Ex) 9.5 36 12 4.00 5.50 S1/S1 85 640 430
FK 17.1-4/12 (Ex) 10.8 43 14 5.00 6.50 S1/S1 92 640 430
FK 17.1-4/16 (Ex) 14.1 69 23 6.60 8.40 S1/S1 107 760 550
T 17-4/8 (Ex) 7.9 37 13 3.50 4.50 S1/– 43 410 338
T 17-4/12 (Ex) 9.4 47 16 4.50 5.80 S1/– 51 445 373
T 17-4/16 (Ex) 13.5 68 23 6.50 8.20 S1/– 62 483 411
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 17.1... FPM - - SiC/SiC, SiC/SiC
T 17... FPM FPM, SiC/SiC - SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 17.1... ǽ ǽ • – ǽ – - -
T 17... ǽ ǽ • • • – - -
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

100 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Dimensions Wilo-EMU FA 10.22W (1450 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

800
439

Wastewater transport
90/ 96

160
ø42,4x2 90 109
AW

110

190
176

15
65

50

50
44
1
92

325
117
317

225

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

170
340

200
298
515

1 374
2

125

380

Dimension drawing Wilo-EMU FA - portable installation

180
2

667
100
170

553
419
489

340

588
120
200
374
440
329

239
124

Ø 344

1 = DN100 PN10 / ANSI B16.1, Class 125, Size 4; 2 = DN100 PN10

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 101
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 10.26W (1450 rpm)

Pump curves Wilo-EMU FA 10.26W - 50 Hz - 1450 rpm


Vortex impeller - Free ball passage: 80 mm

H[m]
10% 15% 20% 25% 30%
40
34% 38% 42% 45% 47%
Ø 318
35
Ø 306
Ø 294
30
49% Ø 282

25 Ø 270
Ø 258
Ø 246
20
Ø 234

15

10

0
0 10 20 30 40 50 60 70 80 Q[m³/h]

0 4 8 12 16 20 Q[l/s]

P2[kW]
Ø 318
Ø 306
Ø 294
12 Ø 282
Ø 270
Ø 258
8 Ø 246
Ø 234
4

0
0 10 20 30 40 50 60 70 80 Q[m³/h]

0 4 8 12 16 20 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 10.26W 80 Vortex impeller 72
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

102 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 10.26W (1450 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-

Wastewater transport
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 202-4/12 16.6 67 23 7.80 9.90 S1/S1 106 726 619
FK 202-4/17 24.5 98 33 11.50 14.60 S1/S1 119 771 664
FK 202-4/22 31.5 125 42 15.00 18.30 S1/S1 138 821 714
FK 202-4/27 37.5 148 49 18.50 23.00 S1/S1 155 871 764
HC 20.1-4/17 (Ex) 21 99 33 10.00 12.10 S1/S1 172 835 730
HC 20.1-4/22 (Ex) 31 126 42 15.00 18.10 S1/S1 188 935 830
HC 20.1-4/30 (Ex) 41 220 74 20.00 24.00 S1/S1 204 935 830
T 17-4/24 (Ex) 21 123 41 10.00 12.20 S1/– 91 563 491
T 20.1-4/22 (Ex) 30.5 156 52 15.00 18.10 S1/S2-15 min 168 764 674
T 20.1-4/30 (Ex) 41 220 73 20.00 24.00 S1/S2-15 min 182 764 674
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 202... NBR - - SiC/SiC, SiC/SiC
HC 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC
T 17... FPM FPM, SiC/SiC - SiC/SiC, SiC/SiC
T 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 202... - - • ǽ ǽ – - -
HC 20.1... ǽ ǽ • • ǽ • - •
T 17... ǽ ǽ • • • – - -
T 20.1... ǽ ǽ • • ǽ • - •
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 103
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Dimensions Wilo-EMU FA 10.26W (1450 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

800
571

90/ 96

160
ø42,4x2
90 109
AW

176

110

190
15
65

50

50
44
1
76

325
101
301

225

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

258
474

280
506
284
485

1
2

125

460

Dimension drawing Wilo-EMU FA - portable installation

180
2

799
100
258

685
405
475

474

720
120
280
506
426
301

225
124

Ø 344

1 = DN100 PN10 / ANSI B16.1, Class 125, Size 4; 2 = DN100 PN10

104 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 10.28W (2900 rpm)

Pump curves Wilo-EMU FA 10.28W - 50 Hz - 2900 rpm


Vortex impeller - Free ball passage: 100 mm

H[m]

Wastewater transport
60
10% 20%
30%
36%
50 Ø 200

Ø 190

40 Ø 180

Ø 170

30
Ø 160

20 Ø 150

10

0
0 20 40 60 80 100 120 140 Q[m³/h]

0 5 10 15 20 25 30 35 40 Q[l/s]

P2[kW]

Ø 200
Ø 190
20 Ø 180
Ø 170 Ø 160 Ø 150
15

10

0
0 20 40 60 80 100 120 140 Q[m³/h]

0 5 10 15 20 25 30 35 40 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 10.28W 100 Vortex impeller 32
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 105
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 10.28W (2900 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 202-2/17 25 115 38 11.50 15.20 S1/S1 119 771 664
FK 202-2/22 34.5 160 53 17.00 21.00 S1/S1 138 821 714
HC 20.1-2/17 (Ex) 22.5 115 38 11.00 13.80 S1/S1 172 835 730
HC 20.1-2/22 (Ex) 30 160 54 15.50 18.60 S1/S1 188 935 830
HC 20.1-2/30 (Ex) 44.5 220 74 23.00 27.50 S1/S1 204 935 830
T 17-2/22 (Ex) 20.5 171 57 10.50 12.30 S1/– 91 563 491
T 20.1-2/22 (Ex) 30 215 71 15.50 18.60 S1/S2-15 min 168 764 674
T 20.1-2/30 (Ex) 45.5 325 52 23.00 28.00 S1/S2-15 min 182 764 674
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 202... NBR - - SiC/SiC, SiC/SiC
HC 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC
T 17... FPM FPM, SiC/SiC - SiC/SiC, SiC/SiC
T 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 202... - - • ǽ ǽ – - -
HC 20.1... ǽ ǽ • • ǽ • - •
T 17... ǽ ǽ • • • – - -
T 20.1... ǽ ǽ • • ǽ • - •
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

106 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Dimensions Wilo-EMU FA 10.28W (2900 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

800

Wastewater transport
443

90/ 96

160
ø42,4x2 90 109
AW

110
176

190
15
65

50

50
44
1
92

325
115
317

225

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

170
340

200
374
298
515

1
2

125

380

Dimension drawing Wilo-EMU FA - portable installation

180
2

667
100
170

553
419
489

340

588
120
200
374
440
329

239
124

Ø 344

1 = DN100 PN10 / ANSI B16.1, Class 125, Size 4; 2 = DN100 PN10

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 107
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 10.33E (1450 rpm)

Pump curves Wilo-EMU FA 10.33E - 50 Hz - 1450 rpm


Single-channel impeller - Free ball passage: 80 mm

H[m]

24

20 50%
60%
65%
70%
73%
75%
16

Ø 249

12
65%

60% Ø 238
8

50% Ø 223

4 Ø 208
Ø 194

0
0 20 40 60 80 100 120 140 Q[m³/h]

0 5 10 15 20 25 30 35 40 Q[l/s]

P2[kW]
Ø 249
6 Ø 238

Ø 223
4
Ø 208
Ø 194
2

0
0 20 40 60 80 100 120 140 Q[m³/h]

0 5 10 15 20 25 30 35 40 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 10.33E 80 Single-channel impeller 31
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

108 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 10.33E (1450 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-

Wastewater transport
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 17.1-4/8 (Ex) 5.7 36.5 12 2.20 3.05 S1/S1 85 640 430
FK 17.1-4/8 (Ex) 9.5 36 12 4.00 5.50 S1/S1 85 640 430
FK 17.1-4/12 (Ex) 10.8 43 14 5.00 6.50 S1/S1 92 640 430
FK 17.1-4/16 (Ex) 14.1 69 23 6.60 8.40 S1/S1 107 760 550
T 17-4/8 (Ex) 7.9 37 13 3.50 4.50 S1/– 43 410 338
T 17-4/12 (Ex) 9.4 47 16 4.50 5.80 S1/– 51 445 373
T 17-4/16 (Ex) 13.5 68 23 6.50 8.20 S1/– 62 483 411
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 17.1... FPM - - SiC/SiC, SiC/SiC
T 17... FPM FPM, SiC/SiC - SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 17.1... ǽ ǽ • – ǽ – - -
T 17... ǽ ǽ • • • – - -
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 109
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Dimensions Wilo-EMU FA 10.33E (1450 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

800
527

90/ 96

160
ø42,4x2 90 109
AW

176

110

190
15
65

50

50
44
1
69

325
294
95

225

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

197
374

269
462
262
441

3
3

110

434

Dimension drawing Wilo-EMU FA - portable installation

180
2

755
100
197
398

642
468

374

676
120
269
462
419
287

218
124

Ø 344

1 = DN100 PN10 / ANSI B16.1, Class 125, Size 4; 2 = DN100 PN10; 3 = DN80 PN10

110 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 10.34E (1450 rpm)

Pump curves Wilo-EMU FA 10.34E - 50 Hz - 1450 rpm


Single-channel impeller - Free ball passage: 80 mm

H[m]

Wastewater transport
28
20%
40%
50%
24 60%
64%
67%
69%
20

16
64%
60%

12 Ø 278

Ø 270

8 Ø 258
50%

Ø 246
4 Ø 234

0
0 40 80 120 160 200 240 Q[m³/h]

0 10 20 30 40 50 60 70 Q[l/s]

P2[kW]
Ø 278
12 Ø 270

Ø 258
8 Ø 246
Ø 234

0
0 40 80 120 160 200 240 Q[m³/h]

0 10 20 30 40 50 60 70 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 10.34E 80 Single-channel impeller 48
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 111
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 10.34E (1450 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 17.1-4/12 (Ex) 10.8 43 14 5.00 6.50 S1/S1 92 640 430
FK 17.1-4/16 (Ex) 14.1 69 23 6.60 8.40 S1/S1 107 760 550
FK 202-4/12 16.6 67 23 7.80 9.90 S1/S1 106 726 619
FK 202-4/17 24.5 98 33 11.50 14.60 S1/S1 119 771 664
FK 202-4/22 31.5 125 42 15.00 18.30 S1/S1 138 821 714
HC 20.1-4/17 (Ex) 21 99 33 10.00 12.10 S1/S1 172 835 730
HC 20.1-4/22 (Ex) 31 126 42 15.00 18.10 S1/S1 188 935 830
T 17-4/12 (Ex) 9.4 47 16 4.50 5.80 S1/– 51 445 373
T 17-4/16 (Ex) 13.5 68 23 6.50 8.20 S1/– 62 483 411
T 17.2-4/24 (Ex) 21 123 41 10.00 12.20 S1/– 91 582 510
T 20.1-4/22 (Ex) 30.5 156 52 15.00 18.10 S1/S2-15 min 168 764 674
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 17.1... FPM - - SiC/SiC, SiC/SiC
FK 202... NBR - - SiC/SiC, SiC/SiC
HC 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC
T 17... FPM FPM, SiC/SiC - SiC/SiC, SiC/SiC
T 17.2... NBR NBR, SiC/SiC - SiC/SiC, SiC/SiC
T 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 17.1... ǽ ǽ • – ǽ – - -
FK 202... - - • ǽ ǽ – - -
HC 20.1... ǽ ǽ • • ǽ • - •
T 17... ǽ ǽ • • • – - -
T 17.2... ǽ ǽ • • • – - -
T 20.1... ǽ ǽ • • ǽ • - •
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

112 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Dimensions Wilo-EMU FA 10.34E (1450 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

800
513

Wastewater transport
90/ 96

160
ø42,4x2 90 109
AW

110
176

190
15
65

50

50
44
1
76

325
105
301

225

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

210
404

245
448
288
489

1
2

125

425

Dimension drawing Wilo-EMU FA - portable installation

180
2

741
100
210

627
409
479

404

662
1

120
245
448
430
304

229
124

Ø 344

1 = DN100 PN10 / ANSI B16.1, Class 125, Size 4; 2 = DN100 PN10

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 113
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 10.41E (1450 rpm)

Pump curves Wilo-EMU FA 10.41E - 50 Hz - 1450 rpm


Single-channel impeller - Free ball passage: 80 mm

H[m]

14

12
34%
44%
54%
10 62%
67%

4
44%
Ø 203
Ø 183
Ø 163 Ø 173 Ø 193
2
Ø 153

0
0 20 40 60 80 100 120 140 160 Q[m³/h]

0 5 10 15 20 25 30 35 40 45 Q[l/s]

P2[kW]

3 Ø 203

Ø 193
2 Ø 183
Ø 173
Ø 163
Ø 153
1

0
0 20 40 60 80 100 120 140 160 Q[m³/h]

0 5 10 15 20 25 30 35 40 45 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 10.41E 80 Single-channel impeller 27.5
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

114 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 10.41E (1450 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-

Wastewater transport
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 17.1-4/8 (Ex) 5.7 36.5 12 2.20 3.05 S1/S1 85 640 430
FK 17.1-4/8 (Ex) 9.5 36 12 4.00 5.50 S1/S1 85 640 430
T 17-4/8 (Ex) 7.9 37 13 3.50 4.50 S1/– 43 410 338
T 17-4/12 (Ex) 9.4 47 16 4.50 5.80 S1/– 51 445 373
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 17.1... FPM - - SiC/SiC, SiC/SiC
T 17... FPM FPM, SiC/SiC - SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 17.1... ǽ ǽ • – ǽ – - -
T 17... ǽ ǽ • • • – - -
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 115
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Dimensions Wilo-EMU FA 10.41E (1450 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

800
527

90/ 96

160
ø42,4x2 90 109
AW

110

190
176

15
65

50

50
44
1
75

325
300
94

225

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

203
364

270
277
477

1 462
2

125

450

Dimension drawing Wilo-EMU FA - portable installation

180
2

755
100
203

641
398
468

364

676
120
270
462
419
293

218
124

Ø 344

1 = DN100 PN10 / ANSI B16.1, Class 125, Size 4; 2 = DN100 PN10

116 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 10.43W (1450 rpm)

Pump curves Wilo-EMU FA 10.43W - 50 Hz - 1450 rpm


Vortex impeller - Free ball passage: 100 mm

H[m]

Wastewater transport
20
30%
40%
45%
18
49%
52%
16

14
52%

12 Ø 260

10 Ø 250
49%

8
Ø 225
6

0
0 20 40 60 80 100 120 140 Q[m³/h]

0 5 10 15 20 25 30 35 40 Q[l/s]

P2[kW]

Ø 260
8 Ø 250

6 Ø 225

0
0 20 40 60 80 100 120 140 Q[m³/h]

0 5 10 15 20 25 30 35 40 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 10.43W 100 Vortex impeller 35
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 117
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 10.43W (1450 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 17.1-4/8 (Ex) 9.5 36 12 4.00 5.50 S1/S1 85 640 430
FK 17.1-4/12 (Ex) 10.8 43 14 5.00 6.50 S1/S1 92 640 430
FK 17.1-4/16 (Ex) 14.1 69 23 6.60 8.40 S1/S1 107 760 550
FK 202-4/12 16.6 67 23 7.80 9.90 S1/S1 106 726 619
FK 202-4/17 24.5 98 33 11.50 14.60 S1/S1 119 771 664
HC 20.1-4/17 (Ex) 21 99 33 10.00 12.10 S1/S1 172 835 730
HC 20.1-4/22 (Ex) 31 126 42 15.00 18.10 S1/S1 188 935 830
T 17-4/16 (Ex) 13.5 68 23 6.50 8.20 S1/– 62 483 411
T 17-4/24 (Ex) 21 123 41 10.00 12.20 S1/– 91 563 491
T 20.1-4/22 (Ex) 30.5 156 52 15.00 18.10 S1/S2-15 min 168 764 674
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 17.1... FPM - - SiC/SiC, SiC/SiC
FK 202... NBR - - SiC/SiC, SiC/SiC
HC 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC
T 17... FPM FPM, SiC/SiC - SiC/SiC, SiC/SiC
T 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 17.1... ǽ ǽ • – ǽ – - -
FK 202... - - • ǽ ǽ – - -
HC 20.1... ǽ ǽ • • ǽ • - •
T 17... ǽ ǽ • • • – - -
T 20.1... ǽ ǽ • • ǽ • - •
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

118 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Dimensions Wilo-EMU FA 10.43W (1450 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

800
439

Wastewater transport
90/ 96

160
ø42,4x2 90 109
AW

176

110

190
15
65

50

50
44
1
92

325
117
317

225

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

170
340

200
374
298
513

1
2

125

380

Dimension drawing Wilo-EMU FA - portable installation

180
2

667
100
170

553
419
489

340

588
120
200
374
440
329

239
124

Ø 344

1 = DN100 PN10 / ANSI B16.1, Class 125, Size 4; 2 = DN100 PN10

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 119
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 10.44W (950 rpm)

Pump curves Wilo-EMU FA 10.44W - 50 Hz - 950 rpm


Vortex impeller - Free ball passage: 100 mm

H[m]

16

30%
40% 45%
14
49%

12
51%

10
45%

8
40%

6 Ø 330

Ø 310
4
30% Ø 290

Ø 250 Ø 278
2
Ø 225
Ø 200
0
0 40 80 120 160 200 240 Q[m³/h]

0 10 20 30 40 50 60 70 Q[l/s]

P2[kW] Ø 330

8 Ø 310

6 Ø 290
Ø 278
4
Ø 250
2 Ø 225
Ø 200
0
0 40 80 120 160 200 240 Q[m³/h]

0 10 20 30 40 50 60 70 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 10.44W 100 Vortex impeller 67
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

120 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 10.44W (950 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-

Wastewater transport
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 17.1-6/16 (Ex) 9.3 40 14 4.00 5.40 S1/S1 107 760 550
FK 202-6/12 10.9 44 15 4.50 5.90 S1/S1 106 726 619
FK 202-6/17 15.3 61 21 6.50 8.30 S1/S1 119 771 664
FK 202-6/22 19.3 82 27 9.00 11.00 S1/S1 138 821 714
FK 202-6/27 24 99 33 11.00 13.80 S1/S1 155 871 764
HC 20.1-6/17 (Ex) 15.3 61 21 7.00 9.00 S1/S1 172 835 730
HC 20.1-6/22 (Ex) 20 82 28 9.00 11.70 S1/S1 188 935 830
HC 20.1-6/32 (Ex) 27.5 99 33 13.00 16.10 S1/S1 207 935 830
T 17-6/16 (Ex) 9.1 39 13 3.70 5.20 S1/– 62 483 411
T 17-6/24 (Ex) 13.6 65 22 6.00 7.70 S1/– 91 563 491
T 20.1-6/22 (Ex) 20 97 33 9.00 11.60 S1/S2-15 min 168 764 674
T 20.1-6/32 (Ex) 27.5 140 47 13.00 16.10 S1/S2-15 min 185 764 674
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 17.1... FPM - - SiC/SiC, SiC/SiC
FK 202... NBR - - SiC/SiC, SiC/SiC
HC 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC
T 17... FPM FPM, SiC/SiC - SiC/SiC, SiC/SiC
T 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 17.1... ǽ ǽ • – ǽ – - -
FK 202... - - • ǽ ǽ – - -
HC 20.1... ǽ ǽ • • ǽ • - •
T 17... ǽ ǽ • • • – - -
T 20.1... ǽ ǽ • • ǽ • - •
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 121
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Dimensions Wilo-EMU FA 10.44W (950 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

800
559

90/ 96

160
ø42,4x2 90 109
AW

110
176

190
15
65

50

50
44
1
107

325
125
332

225

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

210
420

280
494
308
538

1
2

125

460

Dimension drawing Wilo-EMU FA - portable installation

180
2

787
100
210

673
429
499

420

708
1

120
280
494
450
354

249
124

Ø 344

1 = DN100 PN10 / ANSI B16.1, Class 125, Size 4; 2 = DN100 PN10

122 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 10.44W (1450 rpm)

Pump curves Wilo-EMU FA 10.44W - 50 Hz - 1450 rpm


Vortex impeller - Free ball passage: 100 mm

H[m]

Wastewater transport
36
20%
30%
40%
32 45%
Ø 330
49%
28

24 Ø 310
50,9%

20
Ø 290
16
45%

12 40%
Ø 278

8
30%
Ø 250
4
Ø 225
Ø 200
0
0 40 80 120 160 200 240 Q[m³/h]

0 10 20 30 40 50 60 70 Q[l/s]

P2[kW]
Ø 330 Ø 310 Ø 290 Ø 278

15
Ø 250

10
Ø 225
5 Ø 200

0
0 40 80 120 160 200 240 Q[m³/h]

0 10 20 30 40 50 60 70 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 10.44W 100 Vortex impeller 67
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 123
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 10.44W (1450 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 202-4/12 16.6 67 23 7.80 9.90 S1/S1 106 726 619
FK 202-4/17 24.5 98 33 11.50 14.60 S1/S1 119 771 664
FK 202-4/22 31.5 125 42 15.00 18.30 S1/S1 138 821 714
FK 202-4/27 37.5 148 49 18.50 23.00 S1/S1 155 871 764
HC 20.1-4/17 (Ex) 21 99 33 10.00 12.10 S1/S1 172 835 730
HC 20.1-4/22 (Ex) 31 126 42 15.00 18.10 S1/S1 188 935 830
HC 20.1-4/30 (Ex) 41 220 74 20.00 24.00 S1/S1 204 935 830
T 17-4/24 (Ex) 21 123 41 10.00 12.20 S1/– 91 563 491
T 20.1-4/22 (Ex) 30.5 156 52 15.00 18.10 S1/S2-15 min 168 764 674
T 20.1-4/30 (Ex) 41 220 73 20.00 24.00 S1/S2-15 min 182 764 674
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 202... NBR - - SiC/SiC, SiC/SiC
HC 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC
T 17... FPM FPM, SiC/SiC - SiC/SiC, SiC/SiC
T 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 202... - - • ǽ ǽ – - -
HC 20.1... ǽ ǽ • • ǽ • - •
T 17... ǽ ǽ • • • – - -
T 20.1... ǽ ǽ • • ǽ • - •
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

124 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Dimensions Wilo-EMU FA 10.44W (1450 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

800
559

Wastewater transport
90/ 96

160
ø42,4x2 90 109
AW

110
176

190
15
65

50

50
44
1
107

325
125
332

225

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

210
420

280
494
308
538

1
2

125

460

Dimension drawing Wilo-EMU FA - portable installation

180
2

787
100
210

673
429
499

420

708
1

120
280
494
450
354

249
124

Ø 344

1 = DN100 PN10 / ANSI B16.1, Class 125, Size 4; 2 = DN100 PN10

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 125
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 10.51E (1450 rpm)

Pump curves Wilo-EMU FA 10.51E - 50 Hz - 1450 rpm


Single-channel impeller - Free ball passage: 100 mm

H[m]

20%
12
40%
50%
60%
10
68%
72%

Ø 195
4
Ø 187
Ø 179
50% Ø 171
2
40% Ø 163
Ø 155
Ø 147
0
0 40 80 120 160 200 240 Q[m³/h]

0 10 20 30 40 50 60 70 Q[l/s]

P2[kW]
Ø 195

4 Ø 187

3 Ø 179
Ø 171
2 Ø 163
Ø 155
1 Ø 147

0
0 40 80 120 160 200 240 Q[m³/h]

0 10 20 30 40 50 60 70 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 10.51E 100 Single-channel impeller 26
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

126 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 10.51E (1450 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-

Wastewater transport
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 17.1-4/8 (Ex) 5.7 36.5 12 2.20 3.05 S1/S1 85 640 430
FK 17.1-4/8 (Ex) 9.5 36 12 4.00 5.50 S1/S1 85 640 430
FK 17.1-4/12 (Ex) 10.8 43 14 5.00 6.50 S1/S1 92 640 430
FK 17.1-4/16 (Ex) 14.1 69 23 6.60 8.40 S1/S1 107 760 550
T 17-4/8 (Ex) 7.9 37 13 3.50 4.50 S1/– 43 410 338
T 17-4/12 (Ex) 9.4 47 16 4.50 5.80 S1/– 51 445 373
T 17-4/16 (Ex) 13.5 68 23 6.50 8.20 S1/– 62 483 411
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 17.1... FPM - - SiC/SiC, SiC/SiC
T 17... FPM FPM, SiC/SiC - SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 17.1... ǽ ǽ • – ǽ – - -
T 17... ǽ ǽ • • • – - -
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 127
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Dimensions Wilo-EMU FA 10.51E (1450 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

800
438

90/ 96

160
ø42,4x2 90 109
AW

176

110

190
15
65

50

50
44
1
85

325
115
310

225

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

178
345

200
373
298
508

1
2

125

380

Dimension drawing Wilo-EMU FA - portable installation

180
2

666
100
178

552
419
489

345

587
120
200
373
440
324

239
124

Ø 344

1 = DN100 PN10 / ANSI B16.1, Class 125, Size 4; 2 = DN100 PN10

128 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 10.53W (1450 rpm)

Pump curves Wilo-EMU FA 10.53W - 50 Hz - 1450 rpm


Vortex impeller - Free ball passage: 100 mm

H[m]

Wastewater transport
20%
20 30%
40%
18 45%

16

14
Ø 242
12

10 Ø 222

8
Ø 200
6 30%

4 Ø 180
Ø 160
2

0
0 40 80 120 160 200 240 Q[m³/h]

0 10 20 30 40 50 60 70 Q[l/s]

P2[kW] Ø 242
Ø 222

12 Ø 200
Ø 180
8
Ø 160
4

0
0 40 80 120 160 200 240 Q[m³/h]

0 10 20 30 40 50 60 70 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 10.53W 100 Vortex impeller 34
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 129
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 10.53W (1450 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 17.1-4/12 (Ex) 10.8 43 14 5.00 6.50 S1/S1 92 640 430
FK 17.1-4/16 (Ex) 14.1 69 23 6.60 8.40 S1/S1 107 760 550
FK 202-4/12 16.6 67 23 7.80 9.90 S1/S1 106 726 619
FK 202-4/17 24.5 98 33 11.50 14.60 S1/S1 119 771 664
FK 202-4/22 31.5 125 42 15.00 18.30 S1/S1 138 821 714
FK 202-4/27 37.5 148 49 18.50 23.00 S1/S1 155 871 764
HC 20.1-4/17 (Ex) 21 99 33 10.00 12.10 S1/S1 172 835 730
HC 20.1-4/22 (Ex) 31 126 42 15.00 18.10 S1/S1 188 935 830
HC 20.1-4/30 (Ex) 41 220 74 20.00 24.00 S1/S1 204 935 830
T 17-4/12 (Ex) 9.4 47 16 4.50 5.80 S1/– 51 445 373
T 17-4/16 (Ex) 13.5 68 23 6.50 8.20 S1/– 62 483 411
T 17-4/24 (Ex) 21 123 41 10.00 12.20 S1/– 91 563 491
T 20.1-4/22 (Ex) 30.5 156 52 15.00 18.10 S1/S2-15 min 168 764 674
T 20.1-4/30 (Ex) 41 220 73 20.00 24.00 S1/S2-15 min 182 764 674
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 17.1... FPM - - SiC/SiC, SiC/SiC
FK 202... NBR - - SiC/SiC, SiC/SiC
HC 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC
T 17... FPM FPM, SiC/SiC - SiC/SiC, SiC/SiC
T 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 17.1... ǽ ǽ • – ǽ – - -
FK 202... - - • ǽ ǽ – - -
HC 20.1... ǽ ǽ • • ǽ • - •
T 17... ǽ ǽ • • • – - -
T 20.1... ǽ ǽ • • ǽ • - •
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

130 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Dimensions Wilo-EMU FA 10.53W (1450 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

800
439

Wastewater transport
90/ 96

160
ø42,4x2 90 109
AW

110

190
176

15
65

50

50
44
1
92

325
117
317

225

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

170
340

200
374
298
515

1
2

125

380

Dimension drawing Wilo-EMU FA - portable installation

180
2

667
100
170

553
419
489

340

588
120
200
374
440
329

239
124

Ø 344

1 = DN100 PN10 / ANSI B16.1, Class 125, Size 4; 2 = DN100 PN10

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 131
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 10.62E (1450 rpm)

Pump curves Wilo-EMU FA 10.62E - 50 Hz - 1450 rpm


Single-channel impeller - Free ball passage: 80 mm

H[m]

18

45%
16
58%
65% 70%
14

12

10

65%
8
58%
6
Ø 240
4 45% Ø 230
Ø 220
2 Ø 210

0
0 40 80 120 160 200 Q[m³/h]

0 10 20 30 40 50 60 Q[l/s]

P2[kW]

6 Ø 240
Ø 230
Ø 220
4 Ø 210

0
0 40 80 120 160 200 Q[m³/h]

0 10 20 30 40 50 60 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 10.62E 80 Single-channel impeller 33
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

132 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 10.62E (1450 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-

Wastewater transport
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 17.1-4/8 (Ex) 9.5 36 12 4.00 5.50 S1/S1 85 640 430
FK 17.1-4/12 (Ex) 10.8 43 14 5.00 6.50 S1/S1 92 640 430
FK 17.1-4/16 (Ex) 14.1 69 23 6.60 8.40 S1/S1 107 760 550
T 17-4/8 (Ex) 7.9 37 13 3.50 4.50 S1/– 43 410 338
T 17-4/12 (Ex) 9.4 47 16 4.50 5.80 S1/– 51 445 373
T 17-4/16 (Ex) 13.5 68 23 6.50 8.20 S1/– 62 483 411
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 17.1... FPM - - SiC/SiC, SiC/SiC
T 17... FPM FPM, SiC/SiC - SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 17.1... ǽ ǽ • – ǽ – - -
T 17... ǽ ǽ • • • – - -
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 133
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Dimensions Wilo-EMU FA 10.62E (1450 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

800
563

90/ 96

160
ø42,4x2 90 109
AW

110

190
176

15
65

50

50
44
1
68

325
101
293

225

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

231
415

280
498
283
476

1
2

125

460

Dimension drawing Wilo-EMU FA - portable installation

180
2

791
100
231

677
404
474

415

712
1

120
280
498
425
292

224
124

Ø 344

1 = DN100 PN10 / ANSI B16.1, Class 125, Size 4; 2 = DN100 PN10

134 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 10.65E (1450 rpm)

Pump curves Wilo-EMU FA 10.65E - 50 Hz - 1450 rpm


Single-channel impeller - Free ball passage: 80 mm

H[m]

Wastewater transport
40

35 40%
50%
60%
66%
30
70%

25 Ø 318

Ø 306
20 Ø 294

Ø 282
15
66% Ø 270
60%
10
50% Ø 258

5 Ø 246

Ø 234
0
0 40 80 120 160 200 240 Q[m³/h]

0 10 20 30 40 50 60 70 Q[l/s]

P2[kW]
Ø 318
Ø 306
Ø 294
12 Ø 282
Ø 270
Ø 258
8 Ø 246
Ø 234
4

0
0 40 80 120 160 200 240 Q[m³/h]

0 10 20 30 40 50 60 70 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 10.65E 80 Single-channel impeller 77
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 135
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 10.65E (1450 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 17.1-4/16 (Ex) 14.1 69 23 6.60 8.40 S1/S1 107 760 550
FK 202-4/12 16.6 67 23 7.80 9.90 S1/S1 106 726 619
FK 202-4/17 24.5 98 33 11.50 14.60 S1/S1 119 771 664
FK 202-4/22 31.5 125 42 15.00 18.30 S1/S1 138 821 714
FK 202-4/27 37.5 148 49 18.50 23.00 S1/S1 155 871 764
HC 20.1-4/17 (Ex) 21 99 33 10.00 12.10 S1/S1 172 835 730
HC 20.1-4/22 (Ex) 31 126 42 15.00 18.10 S1/S1 188 935 830
HC 20.1-4/30 (Ex) 41 220 74 20.00 24.00 S1/S1 204 935 830
T 17-4/16 (Ex) 13.5 68 23 6.50 8.20 S1/– 62 483 411
T 17.2-4/24 (Ex) 21 123 41 10.00 12.20 S1/– 91 582 510
T 20.1-4/22 (Ex) 30.5 156 52 15.00 18.10 S1/S2-15 min 168 764 674
T 20.1-4/30 (Ex) 41 220 73 20.00 24.00 S1/S2-15 min 182 764 674
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 17.1... FPM - - SiC/SiC, SiC/SiC
FK 202... NBR - - SiC/SiC, SiC/SiC
HC 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC
T 17... FPM FPM, SiC/SiC - SiC/SiC, SiC/SiC
T 17.2... NBR NBR, SiC/SiC - SiC/SiC, SiC/SiC
T 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 17.1... ǽ ǽ • – ǽ – - -
FK 202... - - • ǽ ǽ – - -
HC 20.1... ǽ ǽ • • ǽ • - •
T 17... ǽ ǽ • • • – - -
T 17.2... ǽ ǽ • • • – - -
T 20.1... ǽ ǽ • • ǽ • - •
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

136 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Dimensions Wilo-EMU FA 10.65E (1450 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

800
571

Wastewater transport
90/ 96

160
ø42,4x2 90 109
AW

110

190
176

15
65

50

50
44
1
76

325
100
301

225

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

258
474

280
283
484

1 506
2

125

460

Dimension drawing Wilo-EMU FA - portable installation

180
2

799
100
258

685
401
472

474

720
1

120
280
506
425
300

224
124

Ø 344

1 = DN100 PN10 / ANSI B16.1, Class 125, Size 4; 2 = DN100 PN10

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 137
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 10.68W (1450 rpm)

Pump curves Wilo-EMU FA 10.68W - 50 Hz - 1450 rpm


Vortex impeller - Free ball passage: 100 mm

H[m]

20% 30% 40% 45%


60
50%
54%
Ø 410

50 Ø 390

Ø 370
40
Ø 350

Ø 330
30
Ø 310

20 Ø 290

Ø 270

10

0
0 40 80 120 160 200 240 280 Q[m³/h]

0 10 20 30 40 50 60 70 80 Q[l/s]

P2[kW] Ø 410
60 Ø 390
Ø 370
Ø 350
40 Ø 330
Ø 310
Ø 290
Ø 270
20

0
0 40 80 120 160 200 240 280 Q[m³/h]

0 10 20 30 40 50 60 70 80 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 10.68W 100 Vortex impeller 103
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

138 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 10.68W (1450 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-

Wastewater transport
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 34.1-4/29 108 580 190 55.00 64.00 S1/S1 635 1252 998
FK 34.1-4/33 129 690 230 65.00 76.00 S1/S1 667 1252 998
FK 34.1-4/42 160 840 280 80.00 92.00 S1/S1 715 1372 1118
FKT 27.1-4/22 (Ex) 53 295 98 26.00 30.00 S1/S1 370 1246 820
FKT 27.1-4/28 (Ex) 71 375 124 35.00 40.00 S1/S1 390 1246 820
FKT 27.2-4/32 (Ex) 77 470 160 39.00 44.00 S1/S1 470 1413 985
FKT 27.2-4/40 (Ex) 97 670 220 50.00 56.00 S1/S1 500 1413 985
T 24-4/29 (Ex) 49.5 320 106 25.00 28.50 S1/– 233 931 678
T 24-4/36 (Ex) 68 480 159 34.00 39.00 S1/– 260 1001 748
T 30-4/29 (Ex) 78 440 146 40.00 45.50 S1/– 422 1035 781
T 30-4/35 (Ex) 96 540 179 50.00 57.00 S1/– 456 1095 841
T 30-4/44 (Ex) 116 680 225 62.00 69.00 S1/– 506 1185 931
T 30-4/55 (Ex) 146 820 275 78.00 87.00 S1/– 567 1295 1041
T 34-4/29 (Ex) 106 640 215 55.00 62.00 S1/– 494 1109 855
T 34-4/43 (Ex) 150 970 320 80.00 87.00 S1/– 596 1189 935
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 34.1... NBR - - SiC/SiC, SiC/SiC
FKT 27.1... NBR - - SiC/SiC, SiC/SiC
FKT 27.2... NBR - - SiC/SiC, SiC/SiC
T 24... NBR - - SiC/SiC, SiC/SiC
T 30... NBR - - SiC/SiC, SiC/SiC
T 34... NBR - - SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 34.1... - - • • • – ǽ -
FKT 27.1... ǽ ǽ • • ǽ • - •
FKT 27.2... ǽ ǽ • • ǽ • - •
T 24... ǽ ǽ • ǽ ǽ – ǽ ǽ
T 30... ǽ ǽ • ǽ ǽ – ǽ ǽ
T 34... ǽ ǽ • ǽ ǽ – ǽ ǽ
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 139
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Dimensions Wilo-EMU FA 10.68W (1450 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

DN150 L/ 2RK 210


1000 90 149
1000
DN150 L/ 2RK 90/ 95 DN150 S/ 2RK 120

240
110
50

19

50
875
799
ø42,4x2 DN150 S/ 2RK 291
ø 60,3x3,65 ø18
120
AW

220 241

220

280
140
140

230
AW
95 109
38 62
1 420
1
88

88

540
465
408

210
210

408
320

320
Dimension drawing Wilo-EMU FA - stationary dry well installation
A

290
Ø 580

400
433

690
681

1
2

160

620

Dimension drawing Wilo-EMU FA - portable installation


290
Ø 580

400

690
478

390
180

Ø 500

1 = DN150 PN10 / ANSI B16.1, Class 125, Size 6; 2 = DN150 PN10; 3 = DN100 PN10 / ANSI B16.1, Class 125, Size 4

140 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 10.78Z (1450 rpm)

Pump curves Wilo-EMU FA 10.78Z - 50 Hz - 1450 rpm


Multi-channel impeller - Free ball passage: 80 mm

H[m]

Wastewater transport
60 20%
40% 50%
60%
65%
68%
50 Ø 410

Ø 390
40
70% Ø 370
70%

Ø 350
30
Ø 330

20

10

0
0 40 80 120 160 200 240 Q[m³/h]

0 10 20 30 40 50 60 70 Q[l/s]

P2[kW]

Ø 410 Ø 390
30 Ø 370
Ø 350
20 Ø 330

10

0
0 40 80 120 160 200 240 Q[m³/h]

0 10 20 30 40 50 60 70 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 10.78Z 80 Multi-channel impeller 171
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 141
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 10.78Z (1450 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 202-4/27 37.5 148 49 18.50 23.00 S1/S1 155 871 764
FKT 27.1-4/22 (Ex) 53 295 98 26.00 30.00 S1/S1 370 1246 820
FKT 27.1-4/28 (Ex) 71 375 124 35.00 40.00 S1/S1 390 1246 820
HC 20.1-4/30 (Ex) 41 220 74 20.00 24.00 S1/S1 204 935 830
T 20.1-4/30 (Ex) 41 220 73 20.00 24.00 S1/S2-15 min 182 764 674
T 24-4/29 (Ex) 49.5 320 106 25.00 28.50 S1/– 233 931 678
T 24-4/36 (Ex) 68 480 159 34.00 39.00 S1/– 260 1001 748
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 202... NBR - - SiC/SiC, SiC/SiC
FKT 27.1... NBR - - SiC/SiC, SiC/SiC
HC 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC
T 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC
T 24... NBR - - SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 202... - - • ǽ ǽ – - -
FKT 27.1... ǽ ǽ • • ǽ • - •
HC 20.1... ǽ ǽ • • ǽ • - •
T 20.1... ǽ ǽ • • ǽ • - •
T 24... ǽ ǽ • ǽ ǽ – ǽ ǽ
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

142 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Dimensions Wilo-EMU FA 10.78Z (1450 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

DN100/ 2RK 160


1000 1000 90 109
700 823

Wastewater transport
DN100/ 2RK DN150L/ 2RK

110

190
15
90/ 95 90/ 95

50

50
ø42,4x2 ø42,4x2 DN150L/ 2RK 210
90 149
AW

AW
176 220

110

240
65 95

19
44 38

50

50
1 3
73

73
325

465
137

137
318

393
225

320
Dimension drawing Wilo-EMU FA - stationary dry well installation
A

295
563

350
320
518

1
635
2

125

530

Dimension drawing Wilo-EMU FA - portable installation

180
2

928
100
295
494

815
564

563

849
1

120
350
635
515
387

314
180

Ø 500

1 = DN100 PN10 / ANSI B16.1, Class 125, Size 4; 2 = DN100 PN10; 3 = DN150 PN10 / ANSI B16.1, Class 125, Size 6

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 143
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 10.82E (1450 rpm)

Pump curves Wilo-EMU FA 10.82E - 50 Hz - 1450 rpm


Single-channel impeller - Free ball passage: 100 mm

H[m]

18
40%
50%
16 60%

70%
14 75%

12

10

8 Ø 245

6 Ø 230

Ø 215
4

0
0 50 100 150 200 250 300 350 Q[m³/h]

0 20 40 60 80 100 Q[l/s]

P2[kW]
Ø 245

8 Ø 230

6 Ø 215

0
0 50 100 150 200 250 300 350 Q[m³/h]

0 20 40 60 80 100 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 10.82E 100 Single-channel impeller 57
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

144 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 10.82E (1450 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-

Wastewater transport
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 17.1-4/12 (Ex) 10.8 43 14 5.00 6.50 S1/S1 92 640 430
FK 17.1-4/16 (Ex) 14.1 69 23 6.60 8.40 S1/S1 107 760 550
FK 202-4/12 16.6 67 23 7.80 9.90 S1/S1 106 726 619
FK 202-4/17 24.5 98 33 11.50 14.60 S1/S1 119 771 664
FK 202-4/22 31.5 125 42 15.00 18.30 S1/S1 138 821 714
HC 20.1-4/17 (Ex) 21 99 33 10.00 12.10 S1/S1 172 835 730
HC 20.1-4/22 (Ex) 31 126 42 15.00 18.10 S1/S1 188 935 830
T 17-4/16 (Ex) 13.5 68 23 6.50 8.20 S1/– 62 483 411
T 17.2-4/24 (Ex) 21 123 41 10.00 12.20 S1/– 91 582 510
T 20.1-4/22 (Ex) 30.5 156 52 15.00 18.10 S1/S2-15 min 168 764 674
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 17.1... FPM - - SiC/SiC, SiC/SiC
FK 202... NBR - - SiC/SiC, SiC/SiC
HC 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC
T 17... FPM FPM, SiC/SiC - SiC/SiC, SiC/SiC
T 17.2... NBR NBR, SiC/SiC - SiC/SiC, SiC/SiC
T 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 17.1... ǽ ǽ • – ǽ – - -
FK 202... - - • ǽ ǽ – - -
HC 20.1... ǽ ǽ • • ǽ • - •
T 17... ǽ ǽ • • • – - -
T 17.2... ǽ ǽ • • • – - -
T 20.1... ǽ ǽ • • ǽ • - •
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 145
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Dimensions Wilo-EMU FA 10.82E (1450 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

800
561

90/ 96

160
ø42,4x2 90 109
AW

110

190
176

15
65
50

50
44
1
84

325
117
309

225

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

240
433

280
496
340
584

3
4

160

500

Dimension drawing Wilo-EMU FA - portable installation

180
2

789
100
240
477

676
547

433

710
1

120

280
496
498
381

297
180

Ø 500

1 = DN100 PN10 / ANSI B16.1, Class 125, Size 4; 2 = DN100 PN10; 3 = DN150 PN10 / ANSI B16.1, Class 125, Size 6; 4 = DN150 PN10

146 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 10.84D (1450 rpm)

Pump curves Wilo-EMU FA 10.84D - 50 Hz - 1450 rpm


Multi-channel impeller - Free ball passage: 65 mm

H[m]

Wastewater transport
20% 40%
28 60%
70%

78%
24

20
Ø 278

16

12
Ø 263

Ø 248
8
Ø 233
Ø 218
Ø 203
4

0
0 50 100 150 200 250 300 350 Q[m³/h]

0 20 40 60 80 100 Q[l/s]

P2[kW] Ø 278 Ø 263

Ø 248
12 Ø 233
Ø 218
8 Ø 203

0
0 50 100 150 200 250 300 350 Q[m³/h]

0 20 40 60 80 100 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 10.84D 65 Multi-channel impeller 56
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 147
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 10.84D (1450 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 17.1-4/16 (Ex) 14.1 69 23 6.60 8.40 S1/S1 107 760 550
FK 202-4/12 16.6 67 23 7.80 9.90 S1/S1 106 726 619
FK 202-4/17 24.5 98 33 11.50 14.60 S1/S1 119 771 664
FK 202-4/22 31.5 125 42 15.00 18.30 S1/S1 138 821 714
FK 202-4/27 37.5 148 49 18.50 23.00 S1/S1 155 871 764
HC 20.1-4/17 (Ex) 21 99 33 10.00 12.10 S1/S1 172 835 730
HC 20.1-4/22 (Ex) 31 126 42 15.00 18.10 S1/S1 188 935 830
HC 20.1-4/30 (Ex) 41 220 74 20.00 24.00 S1/S1 204 935 830
T 17-4/16 (Ex) 13.5 68 23 6.50 8.20 S1/– 62 483 411
T 17.2-4/24 (Ex) 21 123 41 10.00 12.20 S1/– 91 582 510
T 20.1-4/22 (Ex) 30.5 156 52 15.00 18.10 S1/S2-15 min 168 764 674
T 20.1-4/30 (Ex) 41 220 73 20.00 24.00 S1/S2-15 min 182 764 674
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 17.1... FPM - - SiC/SiC, SiC/SiC
FK 202... NBR - - SiC/SiC, SiC/SiC
HC 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC
T 17... FPM FPM, SiC/SiC - SiC/SiC, SiC/SiC
T 17.2... NBR NBR, SiC/SiC - SiC/SiC, SiC/SiC
T 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 17.1... ǽ ǽ • – ǽ – - -
FK 202... - - • ǽ ǽ – - -
HC 20.1... ǽ ǽ • • ǽ • - •
T 17... ǽ ǽ • • • – - -
T 17.2... ǽ ǽ • • • – - -
T 20.1... ǽ ǽ • • ǽ • - •
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

148 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Dimensions Wilo-EMU FA 10.84D (1450 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

800
561

Wastewater transport
90/ 96

160
ø42,4x2 90 109
AW

110

190
176

15
65

50

50
44
1
84

325
117
309

225

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

240
433

280
496
340
584

3
4

160

500

Dimension drawing Wilo-EMU FA - portable installation

180
2

789
100
240
477

676
547

433

710
1

120

280
496
498
381

297
180

Ø 500

1 = DN100 PN10 / ANSI B16.1, Class 125, Size 4; 2 = DN100 PN10; 3 = DN150 PN10 / ANSI B16.1, Class 125, Size 6; 4 = DN150 PN10

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 149
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 10.94E (950 rpm)

Pump curves Wilo-EMU FA 10.94E - 50 Hz - 950 rpm


Single-channel impeller - Free ball passage: 100 mm

H[m]
18

16

40%
14 50%
60%

12 68%
73%
76%
10

6
60%

50%
4
40%

2 Ø 318
Ø 306
Ø 270 Ø 282 Ø 294
Ø 246 Ø 258
0
0 40 80 120 160 200 240 280 320 Q[m³/h]

0 10 20 30 40 50 60 70 80 90 Q[l/s]

P2[kW]

6 Ø 318
Ø 306
Ø 294
4
Ø 282
Ø 270
2 Ø 258
Ø 246

0
0 40 80 120 160 200 240 280 320 Q[m³/h]

0 10 20 30 40 50 60 70 80 90 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 10.94E 100 Single-channel impeller 80
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

150 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 10.94E (950 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-

Wastewater transport
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 17.1-6/16 (Ex) 9.3 40 14 4.00 5.40 S1/S1 107 760 550
FK 202-6/12 10.9 44 15 4.50 5.90 S1/S1 106 726 619
FK 202-6/17 15.3 61 21 6.50 8.30 S1/S1 119 771 664
FK 202-6/22 19.3 82 27 9.00 11.00 S1/S1 138 821 714
HC 20.1-6/17 (Ex) 15.3 61 21 7.00 9.00 S1/S1 172 835 730
HC 20.1-6/22 (Ex) 20 82 28 9.00 11.70 S1/S1 188 935 830
T 17-6/16 (Ex) 9.1 39 13 3.70 5.20 S1/– 62 483 411
T 17.2-6/24 (Ex) 13.6 65 22 6.00 7.70 S1/– 91 582 510
T 20.1-6/22 (Ex) 20 97 33 9.00 11.60 S1/S2-15 min 168 764 674
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 17.1... FPM - - SiC/SiC, SiC/SiC
FK 202... NBR - - SiC/SiC, SiC/SiC
HC 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC
T 17... FPM FPM, SiC/SiC - SiC/SiC, SiC/SiC
T 17.2... NBR NBR, SiC/SiC - SiC/SiC, SiC/SiC
T 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 17.1... ǽ ǽ • – ǽ – - -
FK 202... - - • ǽ ǽ – - -
HC 20.1... ǽ ǽ • • ǽ • - •
T 17... ǽ ǽ • • • – - -
T 17.2... ǽ ǽ • • • – - -
T 20.1... ǽ ǽ • • ǽ • - •
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 151
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Dimensions Wilo-EMU FA 10.94E (950 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

800
561

90/ 96

160
ø42,4x2 90 109
AW

110

190
176

15
65
50

50
44
1
84

325
117
309

225

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

240
433

280
496
340
584

3
4

160

500

Dimension drawing Wilo-EMU FA - portable installation

180
2

789
100
240
477

676
547

433

710
1

120

280
496
498
381

297
180

Ø 500

1 = DN100 PN10 / ANSI B16.1, Class 125, Size 4; 2 = DN100 PN10; 3 = DN150 PN10 / ANSI B16.1, Class 125, Size 6; 4 = DN150 PN10

152 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 10.94E (1450 rpm)

Pump curves Wilo-EMU FA 10.94E - 50 Hz - 0.0 rpm


Single-channel impeller - Free ball passage: 100 mm

H[m]

Wastewater transport
40

35
40%
50%
30 60%
66%
70%
74%
25

20
Ø 318

15
Ø 306
Ø 294
66%
10
60%
Ø 282
50% Ø 270
5
40% Ø 258
Ø 246
0
0 40 80 120 160 200 240 280 320 Q[m³/h]

0 10 20 30 40 50 60 70 80 90 Q[l/s]

P2[kW]
Ø 318
Ø 306
15
Ø 294
Ø 282
10 Ø 270
Ø 258
5 Ø 246

0
0 40 80 120 160 200 240 280 320 Q[m³/h]

0 10 20 30 40 50 60 70 80 90 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 10.94E 100 Single-channel impeller 80
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 153
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 10.94E (1450 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 17.1-4/16 (Ex) 14.1 69 23 6.60 8.40 S1/S1 107 760 550
FK 202-4/12 16.6 67 23 7.80 9.90 S1/S1 106 726 619
FK 202-4/17 24.5 98 33 11.50 14.60 S1/S1 119 771 664
FK 202-4/22 31.5 125 42 15.00 18.30 S1/S1 138 821 714
FK 202-4/27 37.5 148 49 18.50 23.00 S1/S1 155 871 764
HC 20.1-4/17 (Ex) 21 99 33 10.00 12.10 S1/S1 172 835 730
HC 20.1-4/22 (Ex) 31 126 42 15.00 18.10 S1/S1 188 935 830
HC 20.1-4/30 (Ex) 41 220 74 20.00 24.00 S1/S1 204 935 830
T 17-4/16 (Ex) 13.5 68 23 6.50 8.20 S1/– 62 483 411
T 17.2-4/24 (Ex) 21 123 41 10.00 12.20 S1/– 91 582 510
T 20.1-4/22 (Ex) 30.5 156 52 15.00 18.10 S1/S2-15 min 168 764 674
T 20.1-4/30 (Ex) 41 220 73 20.00 24.00 S1/S2-15 min 182 764 674
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 17.1... FPM - - SiC/SiC, SiC/SiC
FK 202... NBR - - SiC/SiC, SiC/SiC
HC 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC
T 17... FPM FPM, SiC/SiC - SiC/SiC, SiC/SiC
T 17.2... NBR NBR, SiC/SiC - SiC/SiC, SiC/SiC
T 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 17.1... ǽ ǽ • – ǽ – - -
FK 202... - - • ǽ ǽ – - -
HC 20.1... ǽ ǽ • • ǽ • - •
T 17... ǽ ǽ • • • – - -
T 17.2... ǽ ǽ • • • – - -
T 20.1... ǽ ǽ • • ǽ • - •
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

154 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Dimensions Wilo-EMU FA 10.94E (1450 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

800
561

Wastewater transport
90/ 96

160
ø42,4x2 90 109
AW

110

190
176

15
65

50

50
44
1
84

325
117
309

225

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

240
433

280
496
340
584

3
4

160

500

Dimension drawing Wilo-EMU FA - portable installation

180
2

789
100
240
477

676
547

433

710
1

120

280
496
498
381

297
180

Ø 500

1 = DN100 PN10 / ANSI B16.1, Class 125, Size 4; 2 = DN100 PN10; 3 = DN150 PN10 / ANSI B16.1, Class 125, Size 6; 4 = DN150 PN10

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 155
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 15.20Z (950 rpm)

Pump curves Wilo-EMU FA 15.20Z - 50 Hz - 950 rpm


Multi-channel impeller - Free ball passage: 100 mm

H[m]

40%
5
50%
60%

68%
4

2
50%

Ø 197
Ø 182 Ø 211
1

0
0 40 80 120 160 200 240 280 320 Q[m³/h]

0 10 20 30 40 50 60 70 80 90 Q[l/s]

P2[kW]

Ø 211
2,0
Ø 197
1,5

1,0 Ø 182

0,5

0
0 40 80 120 160 200 240 280 320 Q[m³/h]

0 10 20 30 40 50 60 70 80 90 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 15.20Z 100 Multi-channel impeller 85
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

156 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 15.20Z (950 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-

Wastewater transport
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 17.1-6/8 (Ex) 5.2 17 6 1.80 2.80 S1/S1 85 640 430
FK 17.1-6/12 (Ex) 7.5 29 10 3.10 4.20 S1/S1 92 640 430
T 17-6/8 (Ex) 4.45 17 6 1.75 2.50 S1/– 43 410 338
T 17-6/12 (Ex) 6.2 31 11 2.50 3.45 S1/– 51 445 373
T 17-6/16 (Ex) 9.1 39 13 3.70 5.20 S1/– 62 483 411
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 17.1... FPM - - SiC/SiC, SiC/SiC
T 17... FPM FPM, SiC/SiC - SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 17.1... ǽ ǽ • – ǽ – - -
T 17... ǽ ǽ • • • – - -
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 157
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Dimensions Wilo-EMU FA 15.20Z (950 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

1000
684

90/ 95

210
ø42,4x2 90 149
AW

110
220

240
19
88

50

50
38
1
87

465
121
407

320

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

301
508

350
344
591

1
596
2

160

570

Dimension drawing Wilo-EMU FA - portable installation


301
508

350
596
388

301
180

Ø 500

1 = DN150 PN10 / ANSI B16.1, Class 125, Size 6; 2 = DN150 PN10

158 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 15.21W (950 rpm)

Pump curves Wilo-EMU FA 15.21W - 50 Hz - 950 rpm


Vortex impeller - Free ball passage: 90 mm

H[m]

Wastewater transport
20% 30%
7 35%
40%

3 Ø 242

2 20%

Ø 222
1
Ø 200
Ø 180
Ø 160
0
0 50 100 150 200 250 300 350 400 450 Q[m³/h]

0 20 40 60 80 100 120 Q[l/s]

P2[kW] Ø 242
Ø 222

8
Ø 200
6

4 Ø 180

Ø 160
2

0
0 50 100 150 200 250 300 350 400 450 Q[m³/h]

0 20 40 60 80 100 120 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 15.21W 90 Vortex impeller 71
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 159
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 15.21W (950 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 17.1-6/16 (Ex) 9.3 40 14 4.00 5.40 S1/S1 107 760 550
FK 202-6/12 10.9 44 15 4.50 5.90 S1/S1 106 726 619
FK 202-6/17 15.3 61 21 6.50 8.30 S1/S1 119 771 664
FK 202-6/22 19.3 82 27 9.00 11.00 S1/S1 138 821 714
FK 202-6/27 24 99 33 11.00 13.80 S1/S1 155 871 764
HC 20.1-6/17 (Ex) 15.3 61 21 7.00 9.00 S1/S1 172 835 730
HC 20.1-6/22 (Ex) 20 82 28 9.00 11.70 S1/S1 188 935 830
HC 20.1-6/32 (Ex) 27.5 99 33 13.00 16.10 S1/S1 207 935 830
T 17-6/16 (Ex) 9.1 39 13 3.70 5.20 S1/– 62 483 411
T 17-6/24 (Ex) 13.6 65 22 6.00 7.70 S1/– 91 563 491
T 20.1-6/22 (Ex) 20 97 33 9.00 11.60 S1/S2-15 min 168 764 674
T 20.1-6/32 (Ex) 27.5 140 47 13.00 16.10 S1/S2-15 min 185 764 674
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 17.1... FPM - - SiC/SiC, SiC/SiC
FK 202... NBR - - SiC/SiC, SiC/SiC
HC 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC
T 17... FPM FPM, SiC/SiC - SiC/SiC, SiC/SiC
T 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 17.1... ǽ ǽ • – ǽ – - -
FK 202... - - • ǽ ǽ – - -
HC 20.1... ǽ ǽ • • ǽ • - •
T 17... ǽ ǽ • • • – - -
T 20.1... ǽ ǽ • • ǽ • - •
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

160 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Dimensions Wilo-EMU FA 15.21W (950 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

1000

Wastewater transport
684

90/ 95

210
ø42,4x2 90 149
AW

110
220

240
19
88

50

50
38
1
87

465
121
407

320

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

301
508

350
344
591

1
596
2

160

570

Dimension drawing Wilo-EMU FA - portable installation


301
508

350
596
388

301
180

Ø 500

1 = DN150 PN10 / ANSI B16.1, Class 125, Size 6; 2 = DN150 PN10

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 161
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 15.44W (1450 rpm)

Pump curves Wilo-EMU FA 15.44W - 50 Hz - 1450 rpm


Vortex impeller - Free ball passage: 130 mm

H[m]

32

20%
28
30%
35%
38%
24
40%

20

16

35%
12
30%

8
20% Ø 363
4 Ø 345

Ø 310 Ø 330
Ø 290
0
0 50 100 150 200 250 300 350 400 450 Q[m³/h]

0 20 40 60 80 100 120 Q[l/s]

P2[kW]

Ø 363
30
Ø 345
Ø 330
20 Ø 310
Ø 290
10

0
0 50 100 150 200 250 300 350 400 450 Q[m³/h]

0 20 40 60 80 100 120 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 15.44W 130 Vortex impeller 95
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

162 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 15.44W (1450 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-

Wastewater transport
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 202-4/22 31.5 125 42 15.00 18.30 S1/S1 138 821 714
FK 202-4/27 37.5 148 49 18.50 23.00 S1/S1 155 871 764
FKT 27.1-4/22 (Ex) 53 295 98 26.00 30.00 S1/S1 370 1246 820
FKT 27.1-4/28 (Ex) 71 375 124 35.00 40.00 S1/S1 390 1246 820
HC 20.1-4/22 (Ex) 31 126 42 15.00 18.10 S1/S1 188 935 830
HC 20.1-4/30 (Ex) 41 220 74 20.00 24.00 S1/S1 204 935 830
T 20.1-4/22 (Ex) 30.5 156 52 15.00 18.10 S1/S2-15 min 168 764 674
T 20.1-4/30 (Ex) 41 220 73 20.00 24.00 S1/S2-15 min 182 764 674
T 24-4/29 (Ex) 49.5 320 106 25.00 28.50 S1/– 233 931 678
T 24-4/36 (Ex) 68 480 159 34.00 39.00 S1/– 260 1001 748
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 202... NBR - - SiC/SiC, SiC/SiC
FKT 27.1... NBR - - SiC/SiC, SiC/SiC
HC 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC
T 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC
T 24... NBR - - SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 202... - - • ǽ ǽ – - -
FKT 27.1... ǽ ǽ • • ǽ • - •
HC 20.1... ǽ ǽ • • ǽ • - •
T 20.1... ǽ ǽ • • ǽ • - •
T 24... ǽ ǽ • ǽ ǽ – ǽ ǽ
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 163
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Dimensions Wilo-EMU FA 15.44W (1450 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

1000
736

90/ 95

210
ø42,4x2 90 149
AW

220

110

240
19
88

50

50
38
1
140

465
143
460

320

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

290
579

350
648
366
666

1
2

160

570

Dimension drawing Wilo-EMU FA - portable installation


290
579

350
648
461

322
180

Ø 500

1 = DN150 PN10 / ANSI B16.1, Class 125, Size 6; 2 = DN150 PN10

164 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 15.52E (950 rpm)

Pump curves Wilo-EMU FA 15.52E - 50 Hz - 950 rpm


Single-channel impeller - Free ball passage: 100 mm

H[m]

Wastewater transport
12

10
40%
50%
60%
8 70%
75%

6
Ø 275

4
60%

Ø 260
2 Ø 245
Ø 230
Ø 215
0
0 40 80 120 160 200 240 280 Q[m³/h]

0 10 20 30 40 50 60 70 80 Q[l/s]

P2[kW] Ø 275
Ø 260

3
Ø 245

2 Ø 230
Ø 215
1

0
0 40 80 120 160 200 240 280 Q[m³/h]

0 10 20 30 40 50 60 70 80 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 15.52E 100 Single-channel impeller 82
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 165
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 15.52E (950 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 17.1-6/16 (Ex) 9.3 40 14 4.00 5.40 S1/S1 107 760 550
FK 202-6/12 10.9 44 15 4.50 5.90 S1/S1 106 726 619
FK 202-6/17 15.3 61 21 6.50 8.30 S1/S1 119 771 664
HC 20.1-6/17 (Ex) 15.3 61 21 7.00 9.00 S1/S1 172 835 730
T 17-6/16 (Ex) 9.1 39 13 3.70 5.20 S1/– 62 483 411
T 17.2-6/24 (Ex) 13.6 65 22 6.00 7.70 S1/– 91 582 510
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 17.1... FPM - - SiC/SiC, SiC/SiC
FK 202... NBR - - SiC/SiC, SiC/SiC
HC 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC
T 17... FPM FPM, SiC/SiC - SiC/SiC, SiC/SiC
T 17.2... NBR NBR, SiC/SiC - SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 17.1... ǽ ǽ • – ǽ – - -
FK 202... - - • ǽ ǽ – - -
HC 20.1... ǽ ǽ • • ǽ • - •
T 17... ǽ ǽ • • • – - -
T 17.2... ǽ ǽ • • • – - -
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

166 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Dimensions Wilo-EMU FA 15.52E (950 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

1000

Wastewater transport
684

90/ 95

210
ø42,4x2 90 149
AW

110
220

240
19
88

50

50
38
1
87

465
121
407

320

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

301
508

350
344
591

1
596
2

160

570

Dimension drawing Wilo-EMU FA - portable installation


301
508

350
596
388

301
180

Ø 500

1 = DN150 PN10 / ANSI B16.1, Class 125, Size 6; 2 = DN150 PN10

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 167
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 15.52E (1450 rpm)

Pump curves Wilo-EMU FA 15.52E - 50 Hz - 1450 rpm


Single-channel impeller - Free ball passage: 100 mm

H[m]

24

20
40%
50%
60%
16 70%
74%

12

8
Ø 260
60% Ø 245
4 Ø 230

Ø 215

0
0 50 100 150 200 250 300 350 400 Q[m³/h]

0 20 40 60 80 100 Q[l/s]

P2[kW]
Ø 260
12
Ø 245
8
Ø 230
Ø 215
4

0
0 50 100 150 200 250 300 350 400 Q[m³/h]

0 20 40 60 80 100 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 15.52E 100 Single-channel impeller 82
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

168 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 15.52E (1450 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-

Wastewater transport
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 17.1-4/16 (Ex) 14.1 69 23 6.60 8.40 S1/S1 107 760 550
FK 202-4/12 16.6 67 23 7.80 9.90 S1/S1 106 726 619
FK 202-4/17 24.5 98 33 11.50 14.60 S1/S1 119 771 664
FK 202-4/22 31.5 125 42 15.00 18.30 S1/S1 138 821 714
HC 20.1-4/17 (Ex) 21 99 33 10.00 12.10 S1/S1 172 835 730
HC 20.1-4/22 (Ex) 31 126 42 15.00 18.10 S1/S1 188 935 830
T 17-4/16 (Ex) 13.5 68 23 6.50 8.20 S1/– 62 483 411
T 17.2-4/24 (Ex) 21 123 41 10.00 12.20 S1/– 91 582 510
T 20.1-4/22 (Ex) 30.5 156 52 15.00 18.10 S1/S2-15 min 168 764 674
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 17.1... FPM - - SiC/SiC, SiC/SiC
FK 202... NBR - - SiC/SiC, SiC/SiC
HC 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC
T 17... FPM FPM, SiC/SiC - SiC/SiC, SiC/SiC
T 17.2... NBR NBR, SiC/SiC - SiC/SiC, SiC/SiC
T 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 17.1... ǽ ǽ • – ǽ – - -
FK 202... - - • ǽ ǽ – - -
HC 20.1... ǽ ǽ • • ǽ • - •
T 17... ǽ ǽ • • • – - -
T 17.2... ǽ ǽ • • • – - -
T 20.1... ǽ ǽ • • ǽ • - •
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 169
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Dimensions Wilo-EMU FA 15.52E (1450 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

1000
684

90/ 95

210
ø42,4x2 90 149
AW

110
220

240
19
88

50

50
38
1
87

465
121
407

320

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

301
508

350
344
591

1
596
2

160

570

Dimension drawing Wilo-EMU FA - portable installation


301
508

350
596
388

301
180

Ø 500

1 = DN150 PN10 / ANSI B16.1, Class 125, Size 6; 2 = DN150 PN10

170 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 15.66E (950 rpm)

Pump curves Wilo-EMU FA 15.66E - 50 Hz - 950 rpm


Single-channel impeller - Free ball passage: 80 mm

H[m]

Wastewater transport
16
30%
40%
14
50%

60%
12
65%

10

6
50%

4
40%
30%
2
Ø 320 Ø 340
Ø 280 Ø 300
0
0 40 80 120 160 200 240 280 Q[m³/h]

0 10 20 30 40 50 60 70 80 Q[l/s]

P2[kW]

6
Ø 340

4 Ø 320
Ø 300
Ø 280
2

0
0 40 80 120 160 200 240 280 Q[m³/h]

0 10 20 30 40 50 60 70 80 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 15.66E 80 Single-channel impeller 146
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 171
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 15.66E (950 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 202-6/12 10.9 44 15 4.50 5.90 S1/S1 106 726 619
FK 202-6/17 15.3 61 21 6.50 8.30 S1/S1 119 771 664
FK 202-6/22 19.3 82 27 9.00 11.00 S1/S1 138 821 714
HC 20.1-6/17 (Ex) 15.3 61 21 7.00 9.00 S1/S1 172 835 730
HC 20.1-6/22 (Ex) 20 82 28 9.00 11.70 S1/S1 188 935 830
T 17.2-6/24 (Ex) 13.6 65 22 6.00 7.70 S1/– 91 582 510
T 20.1-6/22 (Ex) 20 97 33 9.00 11.60 S1/S2-15 min 168 764 674
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 202... NBR - - SiC/SiC, SiC/SiC
HC 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC
T 17.2... NBR NBR, SiC/SiC - SiC/SiC, SiC/SiC
T 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 202... - - • ǽ ǽ – - -
HC 20.1... ǽ ǽ • • ǽ • - •
T 17.2... ǽ ǽ • • • – - -
T 20.1... ǽ ǽ • • ǽ • - •
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

172 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Dimensions Wilo-EMU FA 15.66E (950 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

1000

Wastewater transport
754

90/ 95

210
ø42,4x2 90 149
AW

220

110

240
19
88

50

50
38
1
82

465
183
402

320

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

289
533

400
666
406
648

1
2

160

620

Dimension drawing Wilo-EMU FA - portable installation


289
533

400
666
445

363
180

Ø 500

1 = DN150 PN10 / ANSI B16.1, Class 125, Size 6; 2 = DN150 PN10

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 173
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 15.66E (1450 rpm)

Pump curves Wilo-EMU FA 15.66E - 50 Hz - 1450 rpm


Single-channel impeller - Free ball passage: 80 mm

H[m]

40

20%
35
40%
50%
30
60%
65%
25

20

15
50%
10
40% Ø 340

5 Ø 320
Ø 300
Ø 280
Ø 260
0
0 50 100 150 200 250 300 350 400 Q[m³/h]

0 20 40 60 80 100 Q[l/s]

P2[kW]
Ø 340

15 Ø 320

10 Ø 300
Ø 280
Ø 260
5

0
0 50 100 150 200 250 300 350 400 Q[m³/h]

0 20 40 60 80 100 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 15.66E 80 Single-channel impeller 146
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

174 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 15.66E (1450 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-

Wastewater transport
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 202-4/12 16.6 67 23 7.80 9.90 S1/S1 106 726 619
FK 202-4/17 24.5 98 33 11.50 14.60 S1/S1 119 771 664
FK 202-4/22 31.5 125 42 15.00 18.30 S1/S1 138 821 714
FK 202-4/27 37.5 148 49 18.50 23.00 S1/S1 155 871 764
FKT 27.1-4/22 (Ex) 53 295 98 26.00 30.00 S1/S1 370 1246 820
HC 20.1-4/17 (Ex) 21 99 33 10.00 12.10 S1/S1 172 835 730
HC 20.1-4/22 (Ex) 31 126 42 15.00 18.10 S1/S1 188 935 830
HC 20.1-4/30 (Ex) 41 220 74 20.00 24.00 S1/S1 204 935 830
T 17.2-4/24 (Ex) 21 123 41 10.00 12.20 S1/– 91 582 510
T 20.1-4/22 (Ex) 30.5 156 52 15.00 18.10 S1/S2-15 min 168 764 674
T 20.1-4/30 (Ex) 41 220 73 20.00 24.00 S1/S2-15 min 182 764 674
T 24-4/29 (Ex) 49.5 320 106 25.00 28.50 S1/– 233 931 678
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 202... NBR - - SiC/SiC, SiC/SiC
FKT 27.1... NBR - - SiC/SiC, SiC/SiC
HC 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC
T 17.2... NBR NBR, SiC/SiC - SiC/SiC, SiC/SiC
T 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC
T 24... NBR - - SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 202... - - • ǽ ǽ – - -
FKT 27.1... ǽ ǽ • • ǽ • - •
HC 20.1... ǽ ǽ • • ǽ • - •
T 17.2... ǽ ǽ • • • – - -
T 20.1... ǽ ǽ • • ǽ • - •
T 24... ǽ ǽ • ǽ ǽ – ǽ ǽ
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 175
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Dimensions Wilo-EMU FA 15.66E (1450 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

1000
754

90/ 95

210
ø42,4x2 90 149
AW

220

110

240
19
88

50

50
38
1
82

465
183
402

320

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

289
533

400
666
406
648

1
2

160

620

Dimension drawing Wilo-EMU FA - portable installation


289
533

400
666
445

363
180

Ø 500

1 = DN150 PN10 / ANSI B16.1, Class 125, Size 6; 2 = DN150 PN10

176 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 15.77Z (950 rpm)

Pump curves Wilo-EMU FA 15.77Z - 50 Hz - 950 rpm


Multi-channel impeller - Free ball passage: 80 mm

H[m]

Wastewater transport
28

40%
24
60%
65%

20 70%

70%
16
65%

12 60%

40%

4 Ø 410
Ø 350 Ø 370 Ø 390
Ø 330
Ø 310
0
0 100 200 300 400 500 600 Q[m³/h]

0 20 40 60 80 100 120 140 160 180 Q[l/s]

P2[kW]

Ø 410
20
Ø 390
15 Ø 370

10 Ø 350
Ø 330
5 Ø 310

0
0 100 200 300 400 500 600 Q[m³/h]

0 20 40 60 80 100 120 140 160 180 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 15.77Z 80 Multi-channel impeller 186
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 177
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 15.77Z (950 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 202-6/27 24 99 33 11.00 13.80 S1/S1 155 871 764
FKT 27.1-6/22 (Ex) 44.5 210 70 21.00 24.50 S1/S1 370 1246 820
FKT 27.1-6/28 (Ex) 52 260 87 25.00 29.00 S1/S1 390 1246 820
FKT 27.2-6/32 (Ex) 61 440 150 30.00 35.50 S1/S1 470 1413 985
FKT 27.2-6/40 (Ex) 74 520 175 36.50 42.00 S1/S1 500 1413 985
HC 20.1-6/32 (Ex) 27.5 99 33 13.00 16.10 S1/S1 207 935 830
T 20.1-6/32 (Ex) 27.5 140 47 13.00 16.10 S1/S2-15 min 185 764 674
T 24-6/22 (Ex) 33.5 200 66 16.50 19.90 S1/– 211 866 613
T 24-6/28 (Ex) 43 260 86 21.50 26.00 S1/– 233 931 678
T 30-6/28 (Ex) 60 330 109 30.00 34.00 S1/– 416 1035 781
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 202... NBR - - SiC/SiC, SiC/SiC
FKT 27.1... NBR - - SiC/SiC, SiC/SiC
FKT 27.2... NBR - - SiC/SiC, SiC/SiC
HC 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC
T 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC
T 24... NBR - - SiC/SiC, SiC/SiC
T 30... NBR - - SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 202... - - • ǽ ǽ – - -
FKT 27.1... ǽ ǽ • • ǽ • - •
FKT 27.2... ǽ ǽ • • ǽ • - •
HC 20.1... ǽ ǽ • • ǽ • - •
T 20.1... ǽ ǽ • • ǽ • - •
T 24... ǽ ǽ • ǽ ǽ – ǽ ǽ
T 30... ǽ ǽ • ǽ ǽ – ǽ ǽ
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

178 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Dimensions Wilo-EMU FA 15.77Z (950 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

DN150L/ 2RK 530


210
1000 1000 149

Wastewater transport
90 90
120
DN150L/ 2RK 842 95 DN150S/ 2RK

19
842

560
110

240
ø42,4x2

50

50
ø60,3x3,65
220
740
88 89 241 DN150S/ 2RK 18

AW
AW

38 291
62
120
1 1

100
91

220
230

140
660

280
140
465

540
191
191

320
320
481

490
420

70
70

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

318
Ø 603

450
753
453
743

2
3

190

710

Dimension drawing Wilo-EMU FA - stationary dry well installation

22

2
570
1000
920

490
493

747

4
5

710

1 = DN150 PN10 / ANSI B16.1, Class 125, Size 6; 2 = DN200 PN10 / ANSI B16.1, Class 125, Size 8; 3 = DN200 PN10; 4 = DN250 PN10 / ANSI B16.1, Class 125, Size 10;
5 = DN250 PN10

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 179
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 15.77Z (1450 rpm)

Pump curves Wilo-EMU FA 15.77Z - 50 Hz - 1450 rpm


Multi-channel impeller - Free ball passage: 80 mm

H[m]

60
40%
50%
60%
65%
50
70%

40
70%
Ø 410
30
65%

60%
20
Ø 390
Ø 370
50% Ø 350
10
Ø 330
Ø 310
0
0 200 400 600 800 1000 Q[m³/h]

0 40 80 120 160 200 240 280 Q[l/s]

P2[kW]
Ø 410
Ø 390

60 Ø 370

Ø 350
40
Ø 330
Ø 310
20

0
0 200 400 600 800 1000 Q[m³/h]

0 40 80 120 160 200 240 280 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 15.77Z 80 Multi-channel impeller 186
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

180 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 15.77Z (1450 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-

Wastewater transport
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 34.1-4/29 108 580 190 55.00 64.00 S1/S1 635 1252 998
FK 34.1-4/33 129 690 230 65.00 76.00 S1/S1 667 1252 998
FK 34.1-4/42 160 840 280 80.00 92.00 S1/S1 715 1372 1118
FKT 27.1-4/28 (Ex) 71 375 124 35.00 40.00 S1/S1 390 1246 820
FKT 27.2-4/32 (Ex) 77 470 160 39.00 44.00 S1/S1 470 1413 985
FKT 27.2-4/40 (Ex) 97 670 220 50.00 56.00 S1/S1 500 1413 985
T 24-4/36 (Ex) 68 480 159 34.00 39.00 S1/– 260 1001 748
T 30-4/29 (Ex) 78 440 146 40.00 45.50 S1/– 422 1035 781
T 30-4/35 (Ex) 96 540 179 50.00 57.00 S1/– 456 1095 841
T 30-4/44 (Ex) 116 680 225 62.00 69.00 S1/– 506 1185 931
T 30-4/55 (Ex) 146 820 275 78.00 87.00 S1/– 567 1295 1041
T 34-4/29 (Ex) 106 640 215 55.00 62.00 S1/– 494 1109 855
T 34-4/43 (Ex) 150 970 320 80.00 87.00 S1/– 596 1189 935
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 34.1... NBR - - SiC/SiC, SiC/SiC
FKT 27.1... NBR - - SiC/SiC, SiC/SiC
FKT 27.2... NBR - - SiC/SiC, SiC/SiC
T 24... NBR - - SiC/SiC, SiC/SiC
T 30... NBR - - SiC/SiC, SiC/SiC
T 34... NBR - - SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 34.1... - - • • • – ǽ -
FKT 27.1... ǽ ǽ • • ǽ • - •
FKT 27.2... ǽ ǽ • • ǽ • - •
T 24... ǽ ǽ • ǽ ǽ – ǽ ǽ
T 30... ǽ ǽ • ǽ ǽ – ǽ ǽ
T 34... ǽ ǽ • ǽ ǽ – ǽ ǽ
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 181
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Dimensions Wilo-EMU FA 15.77Z (1450 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

DN150L/ 2RK 530


210
1000 1000 149
90 90
120
DN150L/ 2RK 842 95 DN150S/ 2RK

19
842

560
110

240
ø42,4x2

50

50
ø60,3x3,65
220
740
88 89 241 DN150S/ 2RK 18

AW
AW

38 291
62
120
1 1

100
91

220
230

140
660

280
140
465

540
191
191

320
320
481

490

420
70
70

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

318
Ø 603

450
753
453
743

2
3

190

710

Dimension drawing Wilo-EMU FA - stationary dry well installation

22

2
570
1000
920

490
493

747

4
5

710

1 = DN150 PN10 / ANSI B16.1, Class 125, Size 6; 2 = DN200 PN10 / ANSI B16.1, Class 125, Size 8; 3 = DN200 PN10; 4 = DN250 PN10 / ANSI B16.1, Class 125, Size 10;
5 = DN250 PN10

182 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 15.84D (950 rpm)

Pump curves Wilo-EMU FA 15.84D - 50 Hz - 950 rpm


Multi-channel impeller - Free ball passage: 65 mm

H[m]

Wastewater transport
12
40%
60%
10
70%
76%
79%
8

60%
4

Ø 278
40% Ø 263
2
Ø 248
Ø 233
Ø 203 Ø 218

0
0 100 200 300 400 500 Q[m³/h]

0 20 40 60 80 100 120 140 Q[l/s]

P2[kW]
Ø 278
6
Ø 263

Ø 248
4
Ø 233
Ø 218
2 Ø 203

0
0 100 200 300 400 500 Q[m³/h]

0 20 40 60 80 100 120 140 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 15.84D 65 Multi-channel impeller 82
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 183
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 15.84D (950 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 17.1-6/16 (Ex) 9.3 40 14 4.00 5.40 S1/S1 107 760 550
FK 202-6/12 10.9 44 15 4.50 5.90 S1/S1 106 726 619
FK 202-6/17 15.3 61 21 6.50 8.30 S1/S1 119 771 664
FK 202-6/22 19.3 82 27 9.00 11.00 S1/S1 138 821 714
HC 20.1-6/17 (Ex) 15.3 61 21 7.00 9.00 S1/S1 172 835 730
HC 20.1-6/22 (Ex) 20 82 28 9.00 11.70 S1/S1 188 935 830
T 17-6/12 (Ex) 6.2 31 11 2.50 3.45 S1/– 51 445 373
T 17-6/16 (Ex) 9.1 39 13 3.70 5.20 S1/– 62 483 411
T 17.2-6/24 (Ex) 13.6 65 22 6.00 7.70 S1/– 91 582 510
T 20.1-6/22 (Ex) 20 97 33 9.00 11.60 S1/S2-15 min 168 764 674
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 17.1... FPM - - SiC/SiC, SiC/SiC
FK 202... NBR - - SiC/SiC, SiC/SiC
HC 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC
T 17... FPM FPM, SiC/SiC - SiC/SiC, SiC/SiC
T 17.2... NBR NBR, SiC/SiC - SiC/SiC, SiC/SiC
T 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 17.1... ǽ ǽ • – ǽ – - -
FK 202... - - • ǽ ǽ – - -
HC 20.1... ǽ ǽ • • ǽ • - •
T 17... ǽ ǽ • • • – - -
T 17.2... ǽ ǽ • • • – - -
T 20.1... ǽ ǽ • • ǽ • - •
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

184 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Dimensions Wilo-EMU FA 15.84D (950 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

1000

Wastewater transport
684

90/ 95

210
ø42,4x2 90 149
AW

110
220

240
19
88

50

50
38
1
87

465
121
407

320

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

301
508

350
344
591

1
596
2

160

570

Dimension drawing Wilo-EMU FA - portable installation


301
508

350
596
388

301
180

Ø 500

1 = DN150 PN10 / ANSI B16.1, Class 125, Size 6; 2 = DN150 PN10

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 185
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 15.84D (1450 rpm)

Pump curves Wilo-EMU FA 15.84D - 50 Hz - 1450 rpm


Multi-channel impeller - Free ball passage: 65 mm

H[m]

28
40%

24 60%
70%
76%
20
79%
Ø 278
16
Ø 263

12

8 60%

4 Ø 248
Ø 218 Ø 233
Ø 203

0
0 100 200 300 400 500 600 Q[m³/h]

0 20 40 60 80 100 120 140 160 180 Q[l/s]

P2[kW]

20 Ø 278
Ø 263
15 Ø 248
Ø 233
10 Ø 218
Ø 203
5

0
0 100 200 300 400 500 600 Q[m³/h]

0 20 40 60 80 100 120 140 160 180 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 15.84D 65 Multi-channel impeller 82
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

186 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 15.84D (1450 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-

Wastewater transport
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 202-4/17 24.5 98 33 11.50 14.60 S1/S1 119 771 664
FK 202-4/22 31.5 125 42 15.00 18.30 S1/S1 138 821 714
FK 202-4/27 37.5 148 49 18.50 23.00 S1/S1 155 871 764
HC 20.1-4/17 (Ex) 21 99 33 10.00 12.10 S1/S1 172 835 730
HC 20.1-4/22 (Ex) 31 126 42 15.00 18.10 S1/S1 188 935 830
HC 20.1-4/30 (Ex) 41 220 74 20.00 24.00 S1/S1 204 935 830
T 17.2-4/24 (Ex) 21 123 41 10.00 12.20 S1/– 91 582 510
T 20.1-4/22 (Ex) 30.5 156 52 15.00 18.10 S1/S2-15 min 168 764 674
T 20.1-4/30 (Ex) 41 220 73 20.00 24.00 S1/S2-15 min 182 764 674
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 202... NBR - - SiC/SiC, SiC/SiC
HC 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC
T 17.2... NBR NBR, SiC/SiC - SiC/SiC, SiC/SiC
T 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 202... - - • ǽ ǽ – - -
HC 20.1... ǽ ǽ • • ǽ • - •
T 17.2... ǽ ǽ • • • – - -
T 20.1... ǽ ǽ • • ǽ • - •
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 187
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Dimensions Wilo-EMU FA 15.84D (1450 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

1000
684

90/ 95

210
ø42,4x2 90 149
AW

110
220

240
19
88

50

50
38
1
87

465
121
407

320

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

301
508

350
344
591

1
596
2

160

570

Dimension drawing Wilo-EMU FA - portable installation


301
508

350
596
388

301
180

Ø 500

1 = DN150 PN10 / ANSI B16.1, Class 125, Size 6; 2 = DN150 PN10

188 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 15.93E (1450 rpm)

Pump curves Wilo-EMU FA 15.93E - 50 Hz - 1450 rpm


Single-channel impeller - Free ball passage: 125 mm

H[m]

Wastewater transport
40

35

30

25

20 Ø 336

15 Ø 310

10

0
0 100 200 300 400 500 600 700 Q[m³/h]

0 40 80 120 160 200 Q[l/s]

P2[kW]
Ø 336
30

Ø 310
20

10

0
0 100 200 300 400 500 600 700 Q[m³/h]

0 40 80 120 160 200 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 15.93E 125 Single-channel impeller 102
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 189
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 15.93E (1450 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-
immersed)
IN IA P2 P1 A AW
A kW kg mm
FKT 27.1-4/22 (Ex) 53 295 98 26.00 30.00 S1/S1 370 1246 820
FKT 27.1-4/28 (Ex) 71 375 124 35.00 40.00 S1/S1 390 1246 820
T 24-4/29 (Ex) 49.5 320 106 25.00 28.50 S1/– 233 931 678
T 24-4/36 (Ex) 68 480 159 34.00 39.00 S1/– 260 1001 748
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FKT 27.1... NBR - - SiC/SiC, SiC/SiC
T 24... NBR - - SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FKT 27.1... ǽ ǽ • • ǽ • - •
T 24... ǽ ǽ • ǽ ǽ – ǽ ǽ
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

190 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Dimensions Wilo-EMU FA 15.93E (1450 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

1000

Wastewater transport
714

90/ 95

210
ø42,4x2 90 149
AW

220

110

240
19
88

50

50
38
1
99

465
144
419

320

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

320
573

350
407
696

2
626
3

190

610

Dimension drawing Wilo-EMU FA - portable installation


320
573

350
626
433

334
190

Ø 500

1 = DN150 PN10 / ANSI B16.1, Class 125, Size 6; 2 = DN200 PN10 / ANSI B16.1, Class 125, Size 8; 3 = DN200 PN10

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 191
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 15.95E (950 rpm)

Pump curves Wilo-EMU FA 15.95E - 50 Hz - 950 rpm


Single-channel impeller - Free ball passage: 110 mm

H[m]

18
38%
16
48%
58%
14
63%

12
68%

10

4
48%
38%
2
Ø 362
Ø 317 Ø 332 Ø 347
Ø 302
0
0 100 200 300 400 500 Q[m³/h]

0 20 40 60 80 100 120 140 Q[l/s]

P2[kW]

6 Ø 362
Ø 347
4 Ø 332
Ø 317
Ø 302
2

0
0 100 200 300 400 500 Q[m³/h]

0 20 40 60 80 100 120 140 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 15.95E 110 Single-channel impeller 161
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

192 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 15.95E (950 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-

Wastewater transport
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 202-6/12 10.9 44 15 4.50 5.90 S1/S1 106 726 619
FK 202-6/17 15.3 61 21 6.50 8.30 S1/S1 119 771 664
FK 202-6/22 19.3 82 27 9.00 11.00 S1/S1 138 821 714
FK 202-6/27 24 99 33 11.00 13.80 S1/S1 155 871 764
HC 20.1-6/17 (Ex) 15.3 61 21 7.00 9.00 S1/S1 172 835 730
HC 20.1-6/22 (Ex) 20 82 28 9.00 11.70 S1/S1 188 935 830
HC 20.1-6/32 (Ex) 27.5 99 33 13.00 16.10 S1/S1 207 935 830
T 17.2-6/24 (Ex) 13.6 65 22 6.00 7.70 S1/– 91 582 510
T 20.1-6/22 (Ex) 20 97 33 9.00 11.60 S1/S2-15 min 168 764 674
T 20.1-6/32 (Ex) 27.5 140 47 13.00 16.10 S1/S2-15 min 185 764 674
T 24-6/22 (Ex) 33.5 200 66 16.50 19.90 S1/– 211 866 613
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 202... NBR - - SiC/SiC, SiC/SiC
HC 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC
T 17.2... NBR NBR, SiC/SiC - SiC/SiC, SiC/SiC
T 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC
T 24... NBR - - SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 202... - - • ǽ ǽ – - -
HC 20.1... ǽ ǽ • • ǽ • - •
T 17.2... ǽ ǽ • • • – - -
T 20.1... ǽ ǽ • • ǽ • - •
T 24... ǽ ǽ • ǽ ǽ – ǽ ǽ
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 193
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Dimensions Wilo-EMU FA 15.95E (950 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

1000
861

90/ 95

210
ø42,4x2
90 149
AW

220

110

240
19
88

50

50
38
1
99

465
170
419

320

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

375
660

450
773
433
722

2
3

190

710

Dimension drawing Wilo-EMU FA - portable installation


375
660

450
773
459

360
190

Ø 500

1 = DN150 PN10 / ANSI B16.1, Class 125, Size 6; 2 = DN200 PN10 / ANSI B16.1, Class 125, Size 8; 3 = DN200 PN10

194 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 15.95E (1450 rpm)

Pump curves Wilo-EMU FA 15.95E - 50 Hz - 1450 rpm


Single-channel impeller - Free ball passage: 110 mm

H[m]

Wastewater transport
45

40
40%
35
48%
54%
60%
30
65%
25

20

15

Ø 355
10
Ø 347
48%
40% Ø 332
5
Ø 317
Ø 302
0
0 100 200 300 400 500 Q[m³/h]

0 20 40 60 80 100 120 140 Q[l/s]

P2[kW]

30
Ø 355
Ø 347
20
Ø 332
Ø 317
10 Ø 302

0
0 100 200 300 400 500 Q[m³/h]

0 20 40 60 80 100 120 140 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 15.95E 110 Single-channel impeller 161
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 195
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 15.95E (1450 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 202-4/22 31.5 125 42 15.00 18.30 S1/S1 138 821 714
FK 202-4/27 37.5 148 49 18.50 23.00 S1/S1 155 871 764
FKT 27.1-4/22 (Ex) 53 295 98 26.00 30.00 S1/S1 370 1246 820
FKT 27.1-4/28 (Ex) 71 375 124 35.00 40.00 S1/S1 390 1246 820
HC 20.1-4/30 (Ex) 41 220 74 20.00 24.00 S1/S1 204 935 830
T 20.1-4/22 (Ex) 30.5 156 52 15.00 18.10 S1/S2-15 min 168 764 674
T 20.1-4/30 (Ex) 41 220 73 20.00 24.00 S1/S2-15 min 182 764 674
T 24-4/21 (Ex) 35.5 230 76 17.50 20.50 S1/– 207 866 613
T 24-4/29 (Ex) 49.5 320 106 25.00 28.50 S1/– 233 931 678
T 24-4/36 (Ex) 68 480 159 34.00 39.00 S1/– 260 1001 748
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 202... NBR - - SiC/SiC, SiC/SiC
FKT 27.1... NBR - - SiC/SiC, SiC/SiC
HC 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC
T 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC
T 24... NBR - - SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 202... - - • ǽ ǽ – - -
FKT 27.1... ǽ ǽ • • ǽ • - •
HC 20.1... ǽ ǽ • • ǽ • - •
T 20.1... ǽ ǽ • • ǽ • - •
T 24... ǽ ǽ • ǽ ǽ – ǽ ǽ
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

196 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Dimensions Wilo-EMU FA 15.95E (1450 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

1000

Wastewater transport
861

90/ 95

210
ø42,4x2
90 149
AW

220

110

240
19
88

50

50
38
1
99

465
170
419

320

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

375
660

450
773
433
722

2
3

190

710

Dimension drawing Wilo-EMU FA - portable installation


375
660

450
773
459

360
190

Ø 500

1 = DN150 PN10 / ANSI B16.1, Class 125, Size 6; 2 = DN200 PN10 / ANSI B16.1, Class 125, Size 8; 3 = DN200 PN10

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 197
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 15.96Z (1450 rpm)

Pump curves Wilo-EMU FA 15.96Z - 50 Hz - 1450 rpm


Multi-channel impeller - Free ball passage: 80 mm

H[m]
36

32
40%
50%
28
60%
66%
70%
24
73%

20

16
66%

12 Ø 320

Ø 300
8
Ø 280

0
0 100 200 300 400 500 600 700 Q[m³/h]

0 40 80 120 160 200 Q[l/s]

P2[kW]
Ø 320
30
Ø 300

20 Ø 280

10

0
0 100 200 300 400 500 600 700 Q[m³/h]

0 40 80 120 160 200 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 15.96Z 80 Multi-channel impeller 158
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

198 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 15.96Z (1450 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-

Wastewater transport
immersed)
IN IA P2 P1 A AW
A kW kg mm
FKT 27.1-4/22 (Ex) 53 295 98 26.00 30.00 S1/S1 370 1246 820
FKT 27.1-4/28 (Ex) 71 375 124 35.00 40.00 S1/S1 390 1246 820
T 24-4/29 (Ex) 49.5 320 106 25.00 28.50 S1/– 233 931 678
T 24-4/36 (Ex) 68 480 159 34.00 39.00 S1/– 260 1001 748
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FKT 27.1... NBR - - SiC/SiC, SiC/SiC
T 24... NBR - - SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FKT 27.1... ǽ ǽ • • ǽ • - •
T 24... ǽ ǽ • ǽ ǽ – ǽ ǽ
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 199
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Dimensions Wilo-EMU FA 15.96Z (1450 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

1000
861

90/ 95

210
ø42,4x2
90 149
AW

220

110

240
19
88

50

50
38
1
99

465
170
419

320

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

375
660

450
773
433
722

2
3

190

710

Dimension drawing Wilo-EMU FA - portable installation


375
660

450
773
459

360
190

Ø 500

1 = DN150 PN10 / ANSI B16.1, Class 125, Size 6; 2 = DN200 PN10 / ANSI B16.1, Class 125, Size 8; 3 = DN200 PN10

200 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 15.99D (950 rpm)

Pump curves Wilo-EMU FA 15.99D - 50 Hz - 950 rpm


Multi-channel impeller - Free ball passage: 50 mm

H[m]

Wastewater transport
45
50%
60%
40 65%
70%

35 Ø 520

30
70%

25

65% Ø 490
20

Ø 460
15 60%

Ø 430
10

Ø 400
5

0
0 100 200 300 400 500 Q[m³/h]

0 20 40 60 80 100 120 140 Q[l/s]

P2[kW] Ø 490
Ø 520
Ø 460
30 Ø 430
Ø 400
20

10

0
0 100 200 300 400 500 Q[m³/h]

0 20 40 60 80 100 120 140 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 15.99D 50 Multi-channel impeller 280
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 201
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 15.99D (950 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 34.1-6/24 72 340 112 35.00 41.00 S1/S1 595 1252 998
FK 34.1-6/29 95 450 149 47.50 56.00 S1/S1 635 1252 998
FK 34.1-6/33 109 495 164 55.00 64.00 S1/S1 667 1252 998
T 30-6/28 (Ex) 60 330 109 30.00 34.00 S1/– 416 1035 781
T 30-6/35 (Ex) 75 410 136 37.50 42.50 S1/– 456 1095 841
T 30-6/41 (Ex) 88 480 159 44.00 49.50 S1/– 471 1185 931
T 30-6/48 (Ex) 102 580 192 52.00 58.00 S1/– 531 1295 1041
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 34.1... NBR - - SiC/SiC, SiC/SiC
T 30... NBR - - SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 34.1... - - • • • – ǽ -
T 30... ǽ ǽ • ǽ ǽ – ǽ ǽ
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

202 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Dimensions Wilo-EMU FA 15.99D (950 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

Wastewater transport
1200 x 800
949
18
120
291
ø60,3x3,65 120
241

220
140
AW

280
230
140
89
62

1 420
126
446

540
144

320

Dimension drawing Wilo-EMU FA - stationary dry well installation

420
160
19
A

376
Ø 721

740
320

407

2 500
860
3

760

1 = DN150 PN10 / ANSI B16.1, Class 125, Size 6; 2 = DN200 PN10 / ANSI B16.1, Class 125, Size 8; 3 = DN200 PN10

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 203
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 15.99D (1450 rpm)

Pump curves Wilo-EMU FA 15.99D - 50 Hz - 1450 rpm


Multi-channel impeller - Free ball passage: 50 mm

H[m]
40% 50%
60%
65%
70%
90
Ø 520
80

70

Ø 490
60

50
Ø 460
65%
40
Ø 430
30
Ø 400
20

10

0
0 100 200 300 400 500 600 700 Q[m³/h]

0 40 80 120 160 200 Q[l/s]

P2[kW]

Ø 520 Ø 490
120 Ø 460
Ø 430
80 Ø 400

40

0
0 100 200 300 400 500 600 700 Q[m³/h]

0 40 80 120 160 200 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 15.99D 50 Multi-channel impeller 280
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

204 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Pump curves, technical data Wilo-EMU FA 15.99D (1450 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-

Wastewater transport
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 34.1-4/33 129 690 230 65.00 76.00 S1/S1 667 1252 998
FK 34.1-4/42 160 840 280 80.00 92.00 S1/S1 715 1372 1118
FK 34.1-4/29 108 580 190 55.00 64.00 S1/S1 635 1252 998
FK 42.1-4/36 235 1410 470 110.00 131.00 S1/S1 1190 1512 1195
FKT 50.1-4/42 240 1570 525 140.00 148.00 S1/S1 2242 2217 1333
FKT 50.1-4/50 285 2040 680 165.00 173.00 S1/S1 2384 2317 1433
T 30-4/44 (Ex) 116 680 225 62.00 69.00 S1/– 506 1185 931
T 30-4/55 (Ex) 146 820 275 78.00 87.00 S1/– 567 1295 1041
T 34-4/43 (Ex) 150 970 320 80.00 87.00 S1/– 596 1189 935
T 42-4/36 205 1060 350 110.00 120.00 S1/– 1020 1607 1107
T 42-4/42 235 1250 415 125.00 138.00 S1/– 1090 1707 1207
T 42-4/51 265 1510 500 145.00 156.00 S1/– 1160 1757 1257
T 50.1-4/42 300 2050 690 170.00 178.00 S1/– 1906 2217 1333
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 34.1... NBR - - SiC/SiC, SiC/SiC
FK 42.1... NBR - SiC/SiC, SiC/SiC -
FKT 50.1… NBR - SiC/SiC, SiC/SiC -
T 30... NBR - - SiC/SiC, SiC/SiC
T 34... NBR - - SiC/SiC, SiC/SiC
T 42... NBR - SiC/SiC, SiC/SiC -
T 50.1… NBR - SiC/SiC, SiC/SiC -

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 34.1... - - • • • – ǽ -
FK 42.1... - - • • • – ǽ -
FKT 50.1… ǽ ǽ • • – • ǽ •
T 30... ǽ ǽ • ǽ ǽ – ǽ ǽ
T 34... ǽ ǽ • ǽ ǽ – ǽ ǽ
T 42... ǽ - • ǽ ǽ – ǽ ǽ
T 50.1… ǽ ǽ • • • • ǽ •
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 205
Wastewater transport
Submersible pumps for sewage DN 80 to DN 150

Dimensions Wilo-EMU FA 15.99D (1450 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

1200 x 800
949
18
120
291
ø60,3x3,65 120
241

220
140
AW

280
230
140
89
62

1 420
126
446

540
144

320

Dimension drawing Wilo-EMU FA - stationary dry well installation

420
160
19
A

376
Ø 721

740
320

407

2 500
860
3

760

1 = DN150 PN10 / ANSI B16.1, Class 125, Size 6; 2 = DN200 PN10 / ANSI B16.1, Class 125, Size 8; 3 = DN200 PN10

206 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps DN 200 to DN 250

Series description Wilo-EMU FA 20... - 25...

Wilo-EMU FA 20... - 25...

Wastewater transport
y}
Design Technical data
Submersible sewage pump with various cooling systems • Mains connection: 3~400 V, 50 Hz
• Immersed operating mode: S1
Type key • Surfaced operating mode with self-cooling motor: S1
• Protection class: IP 68
Example: Wilo-EMU FA 20.54E + FK 17.1-6/16K Ex • Max. fluid temperature: 3 - 40 °C, higher temperatures on request
Hydraulics: FA 20.54E • Sealing: With rotary shaft seal and mechanical seal, two mechanical
seals or one block seal cartridge, depending on the motor
FA Submersible sewage pump
• Free ball passage: 80 - 200 mm.
20 x10 = nominal diameter of the pressure port, e.g. DN200 • Permanently lubricated roller bearings
54 Performance indicator • Max. immersion depth: 20 m
E Type of impeller
Materials
• Housing parts: EN-GJL or EN-GJS
Motor: FK 17.1-6/16K Ex • Impeller: EN-GJL or EN-GJS
• Static seals: NBR
FK Motor version • Sealing on pump side: SiC/SiC
17 Size • Sealing on motor side: NBR or SiC/SiC
• Shaft: Stainless steel 1.4021
1 Distinctive number
6 Number of poles Equipment/function
16 x10 = package length [mm] • Heavy-duty version made of grey cast iron
K Sealing version • Self-cooling motors with 1- or 2-chamber system
• Simple installation via suspension unit or pump base
Ex Ex-rated
Description/design
Application Submersible sewage pump as submersible monobloc unit for station-
• Pumping of sewage with solid constituents in water treatment sys- ary and portable wet well and dry well installation. Portable installa-
tems and pumping stations tion is possible, depending on type.
• Local drainage, water control and process water extraction
• Applications in construction and industry Hydraulics
The outlet on the pressure side is designed as horizontal flange con-
Special features/product advantages nection. The maximum possible dry matter content is 8%, depending
• Operation in stationary and portable wet well and dry well installation on the hydraulics and impeller type.
• Submersible
• Easy installation due to suspension unit or pump base The following impeller shapes are used:
• Special materials and coatings against abrasion and corrosion • Single-channel impeller (E)
• Longitudinally watertight cable lead-in (depending on motor) • Two-channel impeller (Z)
• Adjustment of duty point by trimming the impeller • Three-channel impeller (D)

Each single and multi-channel hydraulic unit (Z, D) is equipped with a


mobile and stationary wear ring. These contribute long-term to en-
suring the uniform efficiency of the unit.

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 207
Wastewater transport
Submersible pumps DN 200 to DN 250

Series description Wilo-EMU FA 20... - 25...

Motor • Special materials, e.g. Abrasite


Dry motors (T motors) give off their heat directly to the surrounding • Ceram coating C0, C1, C2, C3
fluid via the housing components and can be used in immersed state • Ex-rated according to ATEX or FM
for permanent operation. Depending on the size, they can also be
used in non-immersed state for short-term or permanent operation. Scope of delivery
• Submersible sewage pump
The oil-filled motors (FK motors) and self-cooling dry motors (FKT, • Up to motor size 17, cable lengths are available in fixed lengths
HC motors) give off their heat to the pumped fluid via a built-in heat measured in 10 m intervals; starting from motor size 20, per customer
exchanger. Therefore, these motors are suitable for permanent oper- request
ation in immersed and non-immersed condition or for dry well instal- • Accessories per customer request
lation. • Operating and maintenance manual
All motors have a sealing chamber that protects the motor from fluid
Accessories
ingress. It can be accessed from the outside and can be monitored
with an optional sealing chamber electrode.
• Suspension unit or pump base
• Various pressure outlets and Storz couplings
All filling fluids used are potentially biodegradable and environmen-
• Chains
tally safe.
• Fixation sets with anchor bolts
• Switchgears, relays and plugs
The cable inlet on T, HC and FKT motors is longitudinally watertight.
Up to motor size 17, cable lengths are available in fixed lengths Commissioning
measured in 10 m intervals. Starting from motor size 20, the cable Operation in wet well installation with non-immersed motor
length can be individually configured. The surfacing of self-cooling motors (FK, FKT, HC motors) is permit-
ted.
Sealing
Fluid-side and motor-side sealing is possible in the following ver- In dry motors (T-motor), it is possible to have the motor non-im-
sions depending on the motor type: mersed for short periods if equipped with motor temperature moni-
• Version H: Mechanical seal for the fluid side, rotary shaft seal for the toring with a temperature circuit, or with two temperature circuits
motor side when used in potentially explosive areas. The maximum running time
• Version G: Two independently operating mechanical seals with non-immersed motor depends on the medium and ambient
• Version K: Block seal cartridge with two independently operating me- temperatures. Therefore, it is not possible to provide exact informa-
chanical seals tion about the operating mode and time (e.g. S2-15)!

Dry-running protection
Options
The hydraulic housing must always be immersed to prevent air from
• Special voltages being drawn in. In the case of fluctuating fluid levels, the system
• PTC thermistor sensor should shut down automatically once the minimum water submer-
• Internal or external sealing chamber control sion is reached.
• Monitoring units for leakage and bearing temperature

H/m
Wilo-EMU FA... DN200 ... DN250
100

70
60
50 DN200
40
30

20

10

DN250
2

1
1 10 100 200 300 500 1000 Q/l/s

208 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps DN 200 to DN 250

Pump curves, technical data Wilo-EMU FA 20.34E (950 rpm)

Pump curves Wilo-EMU FA 20.34E - 50 Hz - 950 rpm


Single-channel impeller - Free ball passage: 200 mm

H[m]

Wastewater transport
18 40%
50%
16
60%
65%
14

12

60%
10

50%
8

6
Ø 355
Ø 325 Ø 340
Ø 310
4

0
0 100 200 300 400 500 600 700 Q[m³/h]

0 40 80 120 160 200 Q[l/s]

P2[kW]

30 Ø 355
Ø 340
20 Ø 325
Ø 310

10

0
0 100 200 300 400 500 600 700 Q[m³/h]

0 40 80 120 160 200 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 20.34E 200 Single-channel impeller 266
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 209
Wastewater transport
Submersible pumps DN 200 to DN 250

Pump curves, technical data Wilo-EMU FA 20.34E (950 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 34.1-6/29 95 450 149 47.50 56.00 S1/S1 635 1252 998
FKT 27.1-6/22 (Ex) 44.5 210 70 21.00 24.50 S1/S1 370 1246 820
FKT 27.1-6/28 (Ex) 52 260 87 25.00 29.00 S1/S1 390 1246 820
FKT 27.2-6/32 (Ex) 61 440 150 30.00 35.50 S1/S1 470 1413 985
FKT 27.2-6/40 (Ex) 74 520 175 36.50 42.00 S1/S1 500 1413 985
T 24-6/22 (Ex) 33.5 200 66 16.50 19.90 S1/– 211 866 613
T 24-6/28 (Ex) 43 260 86 21.50 26.00 S1/– 233 931 678
T 30-6/28 (Ex) 60 330 109 30.00 34.00 S1/– 416 1035 781
T 30-6/35 (Ex) 75 410 136 37.50 42.50 S1/– 456 1095 841
T 30-6/41 (Ex) 88 480 159 44.00 49.50 S1/– 471 1185 931
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 34.1... NBR - - SiC/SiC, SiC/SiC
FKT 27.1... NBR - - SiC/SiC, SiC/SiC
FKT 27.2... NBR - - SiC/SiC, SiC/SiC
T 24... NBR - - SiC/SiC, SiC/SiC
T 30... NBR - - SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 34.1... - - • • • – ǽ -
FKT 27.1... ǽ ǽ • • ǽ • - •
FKT 27.2... ǽ ǽ • • ǽ • - •
T 24... ǽ ǽ • ǽ ǽ – ǽ ǽ
T 30... ǽ ǽ • ǽ ǽ – ǽ ǽ
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

210 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps DN 200 to DN 250

Dimensions Wilo-EMU FA 20.34E (950 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

Wastewater transport
1200 x 1000
105
115
956
105
ø42,4x2
AW

120

270

600
290
120
92 285
56 2

25
147

250
560

550
207
557

300
110

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

449
772

1
470
807

500
1
864
2

190

760

Dimension drawing Wilo-EMU FA - portable installation


449
772

500
610

463
300

864

Ø 500

1 = DN200 PN10 / ANSI B16.1, Class 125, Size 8; 2 = DN200 PN10

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 211
Wastewater transport
Submersible pumps DN 200 to DN 250

Pump curves, technical data Wilo-EMU FA 20.54E (950 rpm)

Pump curves Wilo-EMU FA 20.54E - 50 Hz - 950 rpm


Single-channel impeller - Free ball passage: 125 mm

H[m]

14

20%
12
40%
50%
60%
10 70%

75%

6
Ø 309
Ø 297
4 Ø 288
60%
Ø 277
Ø 263
2 Ø 253
Ø 240

0
0 100 200 300 400 500 Q[m³/h]

0 20 40 60 80 100 120 140 Q[l/s]

P2[kW]

12
Ø 309
Ø 297
8
Ø 288
Ø 277
4 Ø 263
Ø 253
Ø 240
0
0 100 200 300 400 500 Q[m³/h]

0 20 40 60 80 100 120 140 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 20.54E 125 Single-channel impeller 135
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

212 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps DN 200 to DN 250

Pump curves, technical data Wilo-EMU FA 20.54E (950 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-

Wastewater transport
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 17.1-6/12 (Ex) 7.5 29 10 3.10 4.20 S1/S1 92 640 430
FK 17.1-6/16 (Ex) 9.3 40 14 4.00 5.40 S1/S1 107 760 550
FK 202-6/12 10.9 44 15 4.50 5.90 S1/S1 106 726 619
FK 202-6/17 15.3 61 21 6.50 8.30 S1/S1 119 771 664
FK 202-6/22 19.3 82 27 9.00 11.00 S1/S1 138 821 714
FK 202-6/27 24 99 33 11.00 13.80 S1/S1 155 871 764
HC 20.1-6/17 (Ex) 15.3 61 21 7.00 9.00 S1/S1 172 835 730
HC 20.1-6/22 (Ex) 20 82 28 9.00 11.70 S1/S1 188 935 830
HC 20.1-6/32 (Ex) 27.5 99 33 13.00 16.10 S1/S1 207 935 830
T 17.2-6/24 (Ex) 13.6 65 22 6.00 7.70 S1/– 91 582 510
T 17-6/16 (Ex) 9.1 39 13 3.70 5.20 S1/– 62 483 411
T 20.1-6/22 (Ex) 20 97 33 9.00 11.60 S1/S2-15 min 168 764 674
T 20.1-6/32 (Ex) 27.5 140 47 13.00 16.10 S1/S2-15 min 185 764 674
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 17.1... FPM - - SiC/SiC, SiC/SiC
FK 202... NBR - - SiC/SiC, SiC/SiC
HC 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC
T 17.2... NBR NBR, SiC/SiC - SiC/SiC, SiC/SiC
T 17... FPM FPM, SiC/SiC - SiC/SiC, SiC/SiC
T 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 17.1... ǽ ǽ • – ǽ – - -
FK 202... - - • ǽ ǽ – - -
HC 20.1... ǽ ǽ • • ǽ • - •
T 17.2... ǽ ǽ • • • – - -
T 17... ǽ ǽ • • • – - -
T 20.1... ǽ ǽ • • ǽ • - •
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 213
Wastewater transport
Submersible pumps DN 200 to DN 250

Dimensions Wilo-EMU FA 20.54E (950 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

1000
105
115

785 105
ø42,4x2

120

270

600
290
120
AW

92 285
56 2

25
97

250
560

550
172
477

300
80

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

358
605

1
435

400
722

1
693
2

190

660

Dimension drawing Wilo-EMU FA - portable installation


358
605

400
459

362

693
190

Ø 500

1 = DN200 PN10 / ANSI B16.1, Class 125, Size 8; 2 = DN200 PN10

214 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps DN 200 to DN 250

Pump curves, technical data Wilo-EMU FA 20.54E (1450 rpm)

Pump curves Wilo-EMU FA 20.54E - 50 Hz - 1450 rpm


Single-channel impeller - Free ball passage: 125 mm

H[m]

Wastewater transport
32

28 30%

50%
60%
24 70%

20

16

Ø 309
12
60% Ø 297

8 Ø 288
Ø 277
Ø 263
50% Ø 253
4
Ø 240
0
0 100 200 300 400 500 600 700 Q[m³/h]

0 40 80 120 160 200 Q[l/s]

P2[kW]

Ø 309

30 Ø 297
Ø 288
20 Ø 277
Ø 263
Ø 253
10
Ø 240
0
0 100 200 300 400 500 600 700 Q[m³/h]

0 40 80 120 160 200 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 20.54E 125 Single-channel impeller 135
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 215
Wastewater transport
Submersible pumps DN 200 to DN 250

Pump curves, technical data Wilo-EMU FA 20.54E (1450 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 202-4/17 24.5 98 33 11.50 14.60 S1/S1 119 771 664
FK 202-4/22 31.5 125 42 15.00 18.30 S1/S1 138 821 714
FK 202-4/27 37.5 148 49 18.50 23.00 S1/S1 155 871 764
FKT 27.1-4/22 (Ex) 53 295 98 26.00 30.00 S1/S1 370 1246 820
FKT 27.1-4/28 (Ex) 71 375 124 35.00 40.00 S1/S1 390 1246 820
HC 20.1-4/22 (Ex) 31 126 42 15.00 18.10 S1/S1 188 935 830
HC 20.1-4/30 (Ex) 41 220 74 20.00 24.00 S1/S1 204 935 830
T 17.2-4/24 (Ex) 21 123 41 10.00 12.20 S1/– 91 582 510
T 20.1-4/22 (Ex) 30.5 156 52 15.00 18.10 S1/S2-15 min 168 764 674
T 20.1-4/30 (Ex) 41 220 73 20.00 24.00 S1/S2-15 min 182 764 674
T 24-4/21 (Ex) 35.5 230 76 17.50 20.50 S1/– 207 866 613
T 24-4/29 (Ex) 49.5 320 106 25.00 28.50 S1/– 233 931 678
T 24-4/36 (Ex) 68 480 159 34.00 39.00 S1/– 260 1001 748
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 202... NBR - - SiC/SiC, SiC/SiC
FKT 27.1... NBR - - SiC/SiC, SiC/SiC
HC 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC
T 17.2... NBR NBR, SiC/SiC - SiC/SiC, SiC/SiC
T 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC
T 24... NBR - - SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 202... - - • ǽ ǽ – - -
FKT 27.1... ǽ ǽ • • ǽ • - •
HC 20.1... ǽ ǽ • • ǽ • - •
T 17.2... ǽ ǽ • • • – - -
T 20.1... ǽ ǽ • • ǽ • - •
T 24... ǽ ǽ • ǽ ǽ – ǽ ǽ
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

216 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps DN 200 to DN 250

Dimensions Wilo-EMU FA 20.54E (1450 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

Wastewater transport
1000
105
115

785 105
ø42,4x2

120

270

600
290
120
AW

92 285
56 2

25
97

250
560

550
172
477

300
80

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

358
605

1
435

400
722

1
693
2

190

660

Dimension drawing Wilo-EMU FA - portable installation


358
605

400
459

362

693
190

Ø 500

1 = DN200 PN10 / ANSI B16.1, Class 125, Size 8; 2 = DN200 PN10

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 217
Wastewater transport
Submersible pumps DN 200 to DN 250

Pump curves, technical data Wilo-EMU FA 20.73D (950 rpm)

Pump curves Wilo-EMU FA 20.73D - 50 Hz - 950 rpm


Multi-channel impeller - Free ball passage: 80 mm

H[m]

12
20%
40%
50%
60%
10
70%

75%
8

4 Ø 278
Ø 268
60%
Ø 258
2 Ø 228 Ø 238 Ø 248

0
0 50 100 150 200 250 300 350 400 450 Q[m³/h]

0 20 40 60 80 100 120 Q[l/s]

P2[kW]
Ø 278
6 Ø 268

Ø 258
Ø 248
4 Ø 238
Ø 228
2

0
0 50 100 150 200 250 300 350 400 450 Q[m³/h]

0 20 40 60 80 100 120 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 20.73D 80 Multi-channel impeller 121
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

218 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps DN 200 to DN 250

Pump curves, technical data Wilo-EMU FA 20.73D (950 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-

Wastewater transport
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 17.1-6/16 (Ex) 9.3 40 14 4.00 5.40 S1/S1 107 760 550
FK 202-6/12 10.9 44 15 4.50 5.90 S1/S1 106 726 619
FK 202-6/17 15.3 61 21 6.50 8.30 S1/S1 119 771 664
FK 202-6/22 19.3 82 27 9.00 11.00 S1/S1 138 821 714
HC 20.1-6/17 (Ex) 15.3 61 21 7.00 9.00 S1/S1 172 835 730
HC 20.1-6/22 (Ex) 20 82 28 9.00 11.70 S1/S1 188 935 830
T 17-6/16 (Ex) 9.1 39 13 3.70 5.20 S1/– 62 483 411
T 17.2-6/24 (Ex) 13.6 65 22 6.00 7.70 S1/– 91 582 510
T 20.1-6/22 (Ex) 20 97 33 9.00 11.60 S1/S2-15 min 168 764 674
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 17.1... FPM - - SiC/SiC, SiC/SiC
FK 202... NBR - - SiC/SiC, SiC/SiC
HC 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC
T 17.2... NBR NBR, SiC/SiC - SiC/SiC, SiC/SiC
T 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 17.1... ǽ ǽ • – ǽ – - -
FK 202... - - • ǽ ǽ – - -
HC 20.1... ǽ ǽ • • ǽ • - •
T 17.2... ǽ ǽ • • • – - -
T 20.1... ǽ ǽ • • ǽ • - •
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 219
Wastewater transport
Submersible pumps DN 200 to DN 250

Dimensions Wilo-EMU FA 20.73D (950 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

1000
105
115

785 105
ø42,4x2

120

270

600
290
120
AW

92 285
56 2

25
97

250
560

550
172
477

300
80

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

358
605

1
435

400
722

1
693
2

190

660

Dimension drawing Wilo-EMU FA - portable installation


358
605

400
459

362

693
190

Ø 500

1 = DN200 PN10 / ANSI B16.1, Class 125, Size 8; 2 = DN200 PN10

220 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps DN 200 to DN 250

Pump curves, technical data Wilo-EMU FA 20.73D (1450 rpm)

Pump curves Wilo-EMU FA 20.73D - 50 Hz - 1450 rpm


Multi-channel impeller - Free ball passage: 80 mm

H[m]

Wastewater transport
28
20%
40%
50%
24 60%

70%
20
75%

16

Ø 278
12
Ø 268

8 Ø 248 Ø 258
Ø 238
Ø 228
4 Ø 210

0
0 100 200 300 400 500 Q[m³/h]

0 20 40 60 80 100 120 140 Q[l/s]

P2[kW]
Ø 278
Ø 268
20
Ø 258
15 Ø 248
Ø 238
Ø 228
10 Ø 210

0
0 100 200 300 400 500 Q[m³/h]

0 20 40 60 80 100 120 140 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 20.73D 80 Multi-channel impeller 121
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 221
Wastewater transport
Submersible pumps DN 200 to DN 250

Pump curves, technical data Wilo-EMU FA 20.73D (1450 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 202-4/17 24.5 98 33 11.50 14.60 S1/S1 119 771 664
FK 202-4/22 31.5 125 42 15.00 18.30 S1/S1 138 821 714
FK 202-4/27 37.5 148 49 18.50 23.00 S1/S1 155 871 764
FKT 27.1-4/22 (Ex) 53 295 98 26.00 30.00 S1/S1 370 1246 820
FKT 27.1-4/28 (Ex) 71 375 124 35.00 40.00 S1/S1 390 1246 820
HC 20.1-4/22 (Ex) 31 126 42 15.00 18.10 S1/S1 188 935 830
HC 20.1-4/30 (Ex) 41 220 74 20.00 24.00 S1/S1 204 935 830
T 17.2-4/24 (Ex) 21 123 41 10.00 12.20 S1/– 91 582 510
T 20.1-4/22 (Ex) 30.5 156 52 15.00 18.10 S1/S2-15 min 168 764 674
T 20.1-4/30 (Ex) 41 220 73 20.00 24.00 S1/S2-15 min 182 764 674
T 24-4/29 (Ex) 49.5 320 106 25.00 28.50 S1/– 233 931 678
T 24-4/36 (Ex) 68 480 159 34.00 39.00 S1/– 260 1001 748
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 202... NBR - - SiC/SiC, SiC/SiC
FKT 27.1... NBR - - SiC/SiC, SiC/SiC
HC 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC
T 17.2... NBR NBR, SiC/SiC - SiC/SiC, SiC/SiC
T 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC
T 24... NBR - - SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 202... - - • ǽ ǽ – - -
FKT 27.1... ǽ ǽ • • ǽ • - •
HC 20.1... ǽ ǽ • • ǽ • - •
T 17.2... ǽ ǽ • • • – - -
T 20.1... ǽ ǽ • • ǽ • - •
T 24... ǽ ǽ • ǽ ǽ – ǽ ǽ
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

222 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps DN 200 to DN 250

Dimensions Wilo-EMU FA 20.73D (1450 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

Wastewater transport
1000
105
115

785 105
ø42,4x2

120

270

600
290
120
AW

92 285
56 2

25
97

250
560

550
172
477

300
80

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

358
605

1
435

400
722

1
693
2

190

660

Dimension drawing Wilo-EMU FA - portable installation


358
605

400
459

362

693
190

Ø 500

1 = DN200 PN10 / ANSI B16.1, Class 125, Size 8; 2 = DN200 PN10

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 223
Wastewater transport
Submersible pumps DN 200 to DN 250

Pump curves, technical data Wilo-EMU FA 20.78D (950 rpm)

Pump curves Wilo-EMU FA 20.78D - 50 Hz - 950 rpm


Multi-channel impeller - Free ball passage: 76 mm

H[m]

40
40%
50%
35 60%
70%
74%
30
77%

25

20
Ø 490
Ø 470
15

Ø 450
10
60% Ø 425

Ø 400
5
Ø 380

0
0 100 200 300 400 500 600 700 800 900 Q[m³/h]

0 40 80 120 160 200 240 Q[l/s]

P2[kW]

60 Ø 490
Ø 470
Ø 450
40
Ø 425
Ø 400
20 Ø 380

0
0 100 200 300 400 500 600 700 800 900 Q[m³/h]

0 40 80 120 160 200 240 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 20.78D 76 Multi-channel impeller 385
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

224 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps DN 200 to DN 250

Pump curves, technical data Wilo-EMU FA 20.78D (950 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-

Wastewater transport
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 34.1-6/24 72 340 112 35.00 41.00 S1/S1 595 1252 998
FK 34.1-6/29 95 450 149 47.50 56.00 S1/S1 635 1252 998
FK 34.1-6/33 109 495 164 55.00 64.00 S1/S1 667 1252 998
FK 34.1-6/42 129 610 205 65.00 75.00 S1/S1 715 1372 1118
FK 34.1-6/50 151 720 240 75.00 86.00 S1/S1 780 1452 1198
FK 34.1-6/60 181 860 285 90.00 103.00 S1/S1 860 1547 1293
T 30-6/28 (Ex) 60 330 109 30.00 34.00 S1/– 416 1035 781
T 30-6/35 (Ex) 75 410 136 37.50 42.50 S1/– 456 1095 841
T 30-6/41 (Ex) 88 480 159 44.00 49.50 S1/– 471 1185 931
T 30-6/48 (Ex) 102 580 192 52.00 58.00 S1/– 531 1295 1041
T 34-6/41 (Ex) 124 670 225 65.00 70.00 S1/– 581 1189 935
T 34-6/50 (Ex) 136 790 265 70.00 78.00 S1/– 647 1259 1005
T 42-6/36 182 910 305 90.00 98.00 S1/– 1020 1607 1107
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 34.1... NBR - - SiC/SiC, SiC/SiC
T 30... NBR - - SiC/SiC, SiC/SiC
T 34... NBR - - SiC/SiC, SiC/SiC
T 42... NBR - SiC/SiC, SiC/SiC -

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 34.1... - - • • • – ǽ -
T 30... ǽ ǽ • ǽ ǽ – ǽ ǽ
T 34... ǽ ǽ • ǽ ǽ – ǽ ǽ
T 42... ǽ - • ǽ ǽ – ǽ ǽ
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 225
Wastewater transport
Submersible pumps DN 200 to DN 250

Dimensions Wilo-EMU FA 20.78D (950 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

160
1400
583
22
160

200
ø60,3x3,65

1054 463

300
200

335

420
106
AW

2
73

1
149

800
797
561
162

412

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

22
430
795

800
720
1
447

149

648

548
2 520
948
3

600

898

1 = DN200 PN10 / ANSI B16.1, Class 125, Size 8; 2 = DN250 PN10 / ANSI B16.1, Class 125, Size 10; 3 = DN250 PN10

226 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps DN 200 to DN 250

Pump curves, technical data Wilo-EMU FA 20.78D (1450 rpm)

Pump curves Wilo-EMU FA 20.78D - 50 Hz - 1450 rpm


Multi-channel impeller - Free ball passage: 76 mm

H[m]

Wastewater transport
90
40%
50%
60%
80
70%

70 75%

60

50
Ø 490
40
Ø 470

30
Ø 450
60% Ø 425
20

Ø 400
10
Ø 380
0
0 200 400 600 800 1000 1200 1400 Q[m³/h]

0 50 100 150 200 250 300 350 400 Q[l/s]

P2[kW] Ø 490
Ø 470

Ø 450
150
Ø 425
100 Ø 400
Ø 380
50

0
0 200 400 600 800 1000 1200 1400 Q[m³/h]

0 50 100 150 200 250 300 350 400 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 20.78D 76 Multi-channel impeller 385
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 227
Wastewater transport
Submersible pumps DN 200 to DN 250

Pump curves, technical data Wilo-EMU FA 20.78D (1450 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 42.1-4/36 235 1410 470 110.00 131.00 S1/S1 1190 1512 1195
FKT 50.1-4/42 240 1570 525 140.00 148.00 S1/S1 2242 2217 1333
FKT 50.1-4/50 285 2040 680 165.00 173.00 S1/S1 2384 2317 1433
FKT 50.1-4/57 340 2480 830 200.00 210.00 S1/S1 2536 2407 1523
FKT 50.1-4/59 395 2740 920 230.00 245.00 S1/S1 2536 2407 1523
T 30-4/55 (Ex) 146 820 275 78.00 87.00 S1/– 567 1295 1041
T 34-4/43 (Ex) 150 970 320 80.00 87.00 S1/– 596 1189 935
T 42-4/36 205 1060 350 110.00 120.00 S1/– 1020 1607 1107
T 42-4/42 235 1250 415 125.00 138.00 S1/– 1090 1707 1207
T 42-4/51 265 1510 500 145.00 156.00 S1/– 1160 1757 1257
T 50.1-4/42 300 2050 690 170.00 178.00 S1/– 1906 2217 1333
T 50.1-4/50 355 2090 700 205.00 215.00 S1/– 2040 2317 1433
T 50.1-4/57 420 3010 1000 245.00 260.00 S1/– 2183 2407 1523
T 50.1-4/59 445 2990 1000 260.00 275.00 S1/– 2183 2407 1523
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 42.1... NBR - SiC/SiC, SiC/SiC -
FKT 50.1… NBR - SiC/SiC, SiC/SiC -
T 30... NBR - - SiC/SiC, SiC/SiC
T 34... NBR - - SiC/SiC, SiC/SiC
T 42... NBR - SiC/SiC, SiC/SiC -
T 50.1… NBR - SiC/SiC, SiC/SiC -

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 42.1... - - • • • – ǽ -
FKT 50.1… ǽ ǽ • • – • ǽ •
T 30... ǽ ǽ • ǽ ǽ – ǽ ǽ
T 34... ǽ ǽ • ǽ ǽ – ǽ ǽ
T 42... ǽ - • ǽ ǽ – ǽ ǽ
T 50.1… ǽ ǽ • • • • ǽ •
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

228 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps DN 200 to DN 250

Dimensions Wilo-EMU FA 20.78D (1450 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

160

Wastewater transport
1400
583
22
160

200
ø60,3x3,65

1054 463

300
200

335

420
106
AW

2
73

1
149

800
797
561
162

412

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

22
430
795

800
720
1
447

149

648

548
2 520
948
3

600

898

1 = DN200 PN10 / ANSI B16.1, Class 125, Size 8; 2 = DN250 PN10 / ANSI B16.1, Class 125, Size 10; 3 = DN250 PN10

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 229
Wastewater transport
Submersible pumps DN 200 to DN 250

Pump curves, technical data Wilo-EMU FA 25.31Z (950 rpm)

Pump curves Wilo-EMU FA 25.31Z - 50 Hz - 950 rpm


Multi-channel impeller - Free ball passage: 125 mm

H[m]

20%
10

40%
9
60%
8
70%
76%
7

6
80%

5
76%

4 70%

60%
3

Ø 278
2
Ø 245 Ø 267
Ø 257
1

0
0 100 200 300 400 500 600 700 800 900 Q[m³/h]

0 40 80 120 160 200 240 Q[l/s]

P2[kW]
Ø 278

8
Ø 267
6
Ø 257
4 Ø 245

0
0 100 200 300 400 500 600 700 800 900 Q[m³/h]

0 40 80 120 160 200 240 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 25.31Z 125 Multi-channel impeller 120
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

230 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps DN 200 to DN 250

Pump curves, technical data Wilo-EMU FA 25.31Z (950 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-

Wastewater transport
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 202-6/12 10.9 44 15 4.50 5.90 S1/S1 106 726 619
FK 202-6/17 15.3 61 21 6.50 8.30 S1/S1 119 771 664
FK 202-6/22 19.3 82 27 9.00 11.00 S1/S1 138 821 714
FK 202-6/27 24 99 33 11.00 13.80 S1/S1 155 871 764
HC 20.1-6/17 (Ex) 15.3 61 21 7.00 9.00 S1/S1 172 835 730
HC 20.1-6/22 (Ex) 20 82 28 9.00 11.70 S1/S1 188 935 830
HC 20.1-6/32 (Ex) 27.5 99 33 13.00 16.10 S1/S1 207 935 830
T 17.2-6/24 (Ex) 13.6 65 22 6.00 7.70 S1/– 91 582 510
T 20.1-6/22 (Ex) 20 97 33 9.00 11.60 S1/S2-15 min 168 764 674
T 20.1-6/32 (Ex) 27.5 140 47 13.00 16.10 S1/S2-15 min 185 764 674
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 202... NBR - - SiC/SiC, SiC/SiC
HC 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC
T 17.2... NBR NBR, SiC/SiC - SiC/SiC, SiC/SiC
T 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 202... - - • ǽ ǽ – - -
HC 20.1... ǽ ǽ • • ǽ • - •
T 17.2... ǽ ǽ • • • – - -
T 20.1... ǽ ǽ • • ǽ • - •
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 231
Wastewater transport
Submersible pumps DN 200 to DN 250

Dimensions Wilo-EMU FA 25.31Z (950 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

1000
105
135

812 105
ø42,4x2

120

270

640
340
AW

120
99 378
60
2

25
95

300
600

600
140
485

250
140

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

400
655

1
403
688

400
3
713
4

190

660

Dimension drawing Wilo-EMU FA - portable installation


400
655

400
425

330

713
190

Ø 500

1 = DN250 PN10 / ANSI B16.1, Class 125, Size 10; 2 = DN250 PN10; 3 = DN200 PN10 / ANSI B16.1, Class 125, Size 8; 4 = DN200 PN10

232 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps DN 200 to DN 250

Pump curves, technical data Wilo-EMU FA 25.32D (950 rpm)

Pump curves Wilo-EMU FA 25.32D - 50 Hz - 950 rpm


Multi-channel impeller - Free ball passage: 80 mm

H[m]

Wastewater transport
12

20%
40%
10 50%

60%

70%
8

80%

Ø 268
Ø 278
2 60%
50% Ø 258
Ø 228 Ø 238 Ø 248

0
0 100 200 300 400 500 600 Q[m³/h]

0 20 40 60 80 100 120 140 160 180 Q[l/s]

P2[kW]

Ø 278
4 Ø 268
Ø 258
Ø 228 Ø 238Ø 248
2

0
0 100 200 300 400 500 600 Q[m³/h]

0 20 40 60 80 100 120 140 160 180 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 25.32D 80 Multi-channel impeller 120
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 233
Wastewater transport
Submersible pumps DN 200 to DN 250

Pump curves, technical data Wilo-EMU FA 25.32D (950 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 17.1-6/16 (Ex) 9.3 40 14 4.00 5.40 S1/S1 107 760 550
FK 202-6/12 10.9 44 15 4.50 5.90 S1/S1 106 726 619
FK 202-6/17 15.3 61 21 6.50 8.30 S1/S1 119 771 664
FK 202-6/22 19.3 82 27 9.00 11.00 S1/S1 138 821 714
HC 20.1-6/17 (Ex) 15.3 61 21 7.00 9.00 S1/S1 172 835 730
HC 20.1-6/22 (Ex) 20 82 28 9.00 11.70 S1/S1 188 935 830
T 17.2-6/24 (Ex) 13.6 65 22 6.00 7.70 S1/– 91 582 510
T 20.1-6/22 (Ex) 20 97 33 9.00 11.60 S1/S2-15 min 168 764 674
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 17.1... FPM - - SiC/SiC, SiC/SiC
FK 202... NBR - - SiC/SiC, SiC/SiC
HC 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC
T 17.2... NBR NBR, SiC/SiC - SiC/SiC, SiC/SiC
T 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 17.1... ǽ ǽ • – ǽ – - -
FK 202... - - • ǽ ǽ – - -
HC 20.1... ǽ ǽ • • ǽ • - •
T 17.2... ǽ ǽ • • • – - -
T 20.1... ǽ ǽ • • ǽ • - •
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

234 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps DN 200 to DN 250

Dimensions Wilo-EMU FA 25.32D (950 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

Wastewater transport
1000
105
135

812 105
ø42,4x2

120

270

640
340
AW

120
99 378
60
2

25
95

300
600

600
140
485

250
140

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

400
655

1
403
688

400
3
713
4

190

660

Dimension drawing Wilo-EMU FA - portable installation


400
655

400
425

330

713
190

Ø 500

1 = DN250 PN10 / ANSI B16.1, Class 125, Size 10; 2 = DN250 PN10; 3 = DN200 PN10 / ANSI B16.1, Class 125, Size 8; 4 = DN200 PN10

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 235
Wastewater transport
Submersible pumps DN 200 to DN 250

Pump curves, technical data Wilo-EMU FA 25.32D (1450 rpm)

Pump curves Wilo-EMU FA 25.32D - 50 Hz - 1450 rpm


Multi-channel impeller - Free ball passage: 80 mm

H[m]

24

20%

40%
20
50%

60%
16
70%

75%
12

60%
4
50%
Ø 258
Ø 248
Ø 228 Ø 238

0
0 100 200 300 400 500 600 700 800 Q[m³/h]

0 40 80 120 160 200 Q[l/s]

P2[kW]

15 Ø 258
Ø 248
10 Ø 228 Ø 238

0
0 100 200 300 400 500 600 700 800 Q[m³/h]

0 40 80 120 160 200 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 25.32D 80 Multi-channel impeller 120
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

236 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps DN 200 to DN 250

Pump curves, technical data Wilo-EMU FA 25.32D (1450 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-

Wastewater transport
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 202-4/22 31.5 125 42 15.00 18.30 S1/S1 138 821 714
FK 202-4/27 37.5 148 49 18.50 23.00 S1/S1 155 871 764
HC 20.1-4/22 (Ex) 31 126 42 15.00 18.10 S1/S1 188 935 830
HC 20.1-4/30 (Ex) 41 220 74 20.00 24.00 S1/S1 204 935 830
T 20.1-4/22 (Ex) 30.5 156 52 15.00 18.10 S1/S2-15 min 168 764 674
T 20.1-4/30 (Ex) 41 220 73 20.00 24.00 S1/S2-15 min 182 764 674
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 202... NBR - - SiC/SiC, SiC/SiC
HC 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC
T 20.1... NBR - C/ceramic, SiC/SiC SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 202... - - • ǽ ǽ – - -
HC 20.1... ǽ ǽ • • ǽ • - •
T 20.1... ǽ ǽ • • ǽ • - •
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 237
Wastewater transport
Submersible pumps DN 200 to DN 250

Dimensions Wilo-EMU FA 25.32D (1450 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

1000
105
135

812 105
ø42,4x2

120

270

640
340
AW

120
99 378
60
2

25
95

300
600

600
140
485

250
140

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

400
655

1
403
688

400
3
713
4

190

660

Dimension drawing Wilo-EMU FA - portable installation


400
655

400
425

330

713
190

Ø 500

1 = DN250 PN10 / ANSI B16.1, Class 125, Size 10; 2 = DN250 PN10; 3 = DN200 PN10 / ANSI B16.1, Class 125, Size 8; 4 = DN200 PN10

238 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps DN 200 to DN 250

Pump curves, technical data Wilo-EMU FA 25.36E (1450 rpm)

Pump curves Wilo-EMU FA 25.36E - 50 Hz - 1450 rpm


Single-channel impeller - Free ball passage: 150 mm

H[m]

Wastewater transport
45
20%
40%
40
50%
60%
35
70%
30
70%

25
60%

20
Ø 360
15
Ø 338
10
Ø 316

0
0 100 200 300 400 500 600 700 800 900 Q[m³/h]

0 40 80 120 160 200 240 Q[l/s]

P2[kW]
Ø 360

60 Ø 338

40 Ø 316

20

0
0 100 200 300 400 500 600 700 800 900 Q[m³/h]

0 40 80 120 160 200 240 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 25.36E 150 Single-channel impeller 247
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 239
Wastewater transport
Submersible pumps DN 200 to DN 250

Pump curves, technical data Wilo-EMU FA 25.36E (1450 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 34.1-4/29 108 580 190 55.00 64.00 S1/S1 635 1252 998
FK 34.1-4/33 129 690 230 65.00 76.00 S1/S1 667 1252 998
FK 34.1-4/42 160 840 280 80.00 92.00 S1/S1 715 1372 1118
FKT 27.2-4/32 (Ex) 77 470 160 39.00 44.00 S1/S1 470 1413 985
FKT 27.2-4/40 (Ex) 97 670 220 50.00 56.00 S1/S1 500 1413 985
T 30-4/29 (Ex) 78 440 146 40.00 45.50 S1/– 422 1035 781
T 30-4/35 (Ex) 96 540 179 50.00 57.00 S1/– 456 1095 841
T 30-4/44 (Ex) 116 680 225 62.00 69.00 S1/– 506 1185 931
T 30-4/55 (Ex) 146 820 275 78.00 87.00 S1/– 567 1295 1041
T 34-4/29 (Ex) 106 640 215 55.00 62.00 S1/– 494 1109 855
T 34-4/43 (Ex) 150 970 320 80.00 87.00 S1/– 596 1189 935
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 34.1... NBR - - SiC/SiC, SiC/SiC
FKT 27.2... NBR - - SiC/SiC, SiC/SiC
T 30... NBR - - SiC/SiC, SiC/SiC
T 34... NBR - - SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 34.1... - - • • • – ǽ -
FKT 27.2... ǽ ǽ • • ǽ • - •
T 30... ǽ ǽ • ǽ ǽ – ǽ ǽ
T 34... ǽ ǽ • ǽ ǽ – ǽ ǽ
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

240 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps DN 200 to DN 250

Dimensions Wilo-EMU FA 25.36E (1450 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

1200 x 1000

Wastewater transport
105
1013 135
105

ø42,4x2

120
120

270

640
340
99
378

25
60 300
2 600
AW

147

600
200
597

250

3
200

Dimension drawing Wilo-EMU FA - stationary dry well installation

22

> 420
M20
A

450
775

1100
680

600

1200
1

550 420
> 420

914
645

498
744

1100
1200
> 1520
2

917

1 = DN250 PN10 / ANSI B16.1, Class 125, Size 10; 2 = DN250 PN10; 3 = DN200 PN10 / ANSI B16.1, Class 125, Size 8; 4 = DN200 PN10

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 241
Wastewater transport
Submersible pumps DN 200 to DN 250

Pump curves, technical data Wilo-EMU FA 25.74E (950 rpm)

Pump curves Wilo-EMU FA 25.74E - 50 Hz - 950 rpm


Single-channel impeller - Free ball passage: 140 mm

H[m]
36
20%

32
40%
28
50%

24
60%

20
70%

16
60%
12
Ø 480
8 Ø 460
Ø 440
4 Ø 420

0
0 200 400 600 800 1000 1200 Q[m³/h]

0 50 100 150 200 250 300 350 Q[l/s]

P2[kW]

60 Ø 480

Ø 460
40
Ø 440
Ø 420
20

0
0 200 400 600 800 1000 1200 Q[m³/h]

0 50 100 150 200 250 300 350 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 25.74E 140 Single-channel impeller 310
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

242 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps DN 200 to DN 250

Pump curves, technical data Wilo-EMU FA 25.74E (950 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-

Wastewater transport
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 34.1-6/29 95 450 149 47.50 56.00 S1/S1 635 1252 998
FK 34.1-6/33 109 495 164 55.00 64.00 S1/S1 667 1252 998
FK 34.1-6/42 129 610 205 65.00 75.00 S1/S1 715 1372 1118
FK 34.1-6/50 151 720 240 75.00 86.00 S1/S1 780 1452 1198
FKT 27.1-6/28 (Ex) 52 260 87 25.00 29.00 S1/S1 390 1246 820
FKT 27.2-6/32 (Ex) 61 440 150 30.00 35.50 S1/S1 470 1413 985
FKT 27.2-6/40 (Ex) 74 520 175 36.50 42.00 S1/S1 500 1413 985
T 30-6/28 (Ex) 60 330 109 30.00 34.00 S1/– 416 1035 781
T 30-6/35 (Ex) 75 410 136 37.50 42.50 S1/– 456 1095 841
T 30-6/41 (Ex) 88 480 159 44.00 49.50 S1/– 471 1185 931
T 30-6/48 (Ex) 102 580 192 52.00 58.00 S1/– 531 1295 1041
T 34-6/29 (Ex) 85 490 162 45.00 49.00 S1/– 494 1109 855
T 34-6/41 (Ex) 124 670 225 65.00 70.00 S1/– 581 1189 935
T 34-6/50 (Ex) 136 790 265 70.00 78.00 S1/– 647 1259 1005
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 34.1... NBR - - SiC/SiC, SiC/SiC
FKT 27.1... NBR - - SiC/SiC, SiC/SiC
FKT 27.2... NBR - - SiC/SiC, SiC/SiC
T 30... NBR - - SiC/SiC, SiC/SiC
T 34... NBR - - SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 34.1... - - • • • – ǽ -
FKT 27.1... ǽ ǽ • • ǽ • - •
FKT 27.2... ǽ ǽ • • ǽ • - •
T 30... ǽ ǽ • ǽ ǽ – ǽ ǽ
T 34... ǽ ǽ • ǽ ǽ – ǽ ǽ
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 243
Wastewater transport
Submersible pumps DN 200 to DN 250

Dimensions Wilo-EMU FA 25.74E (950 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

1400 x 1200
105
1172 135
105

ø42,4x2

120
120

270

640
340
99
378

25
60 300
2 600
AW

117

600
198
567

250

2
200

Dimension drawing Wilo-EMU FA - stationary dry well installation

22
> 420

M20
523
930

1100
680

600

1200
A

630
> 420

420
1073
470
587

710

1100
1200
2

> 1520
1079

1 = DN250 PN10 / ANSI B16.1, Class 125, Size 10; 2 = DN250 PN10

244 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps DN 200 to DN 250

Pump curves, technical data Wilo-EMU FA 25.82Z (740 rpm)

Pump curves Wilo-EMU FA 25.82Z - 50 Hz - 740 rpm


Multi-channel impeller - Free ball passage: 110 mm

H[m]

Wastewater transport
20
20%
18 40%
50%
60%
16
70%
75%
14

12
80%

10

8
70%

6 60%

4 50% Ø 475

Ø 405 Ø 440
2

0
0 200 400 600 800 1000 1200 1400 1600 Q[m³/h]

0 50 100 150 200 250 300 350 400 450 Q[l/s]

P2[kW]

Ø 475
30

Ø 440
20
Ø 405
10

0
0 200 400 600 800 1000 1200 1400 1600 Q[m³/h]

0 50 100 150 200 250 300 350 400 450 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 25.82Z 110 Multi-channel impeller 317
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 245
Wastewater transport
Submersible pumps DN 200 to DN 250

Pump curves, technical data Wilo-EMU FA 25.82Z (740 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 34.1-8/29 64 335 111 30.00 34.50 S1/S1 635 1252 998
FK 34.1-8/33 74 390 129 35.00 40.00 S1/S1 667 1252 998
FK 34.1-8/42 94 500 165 45.00 51.00 S1/S1 715 1372 1118
FK 34.1-8/50 115 600 198 55.00 62.00 S1/S1 780 1452 1198
FKT 27.1-8/28 (Ex) 38.5 175 59 18.00 21.50 S1/S1 390 1246 820
FKT 27.2-8/32 (Ex) 50 300 100 23.50 27.50 S1/S1 470 1413 985
FKT 27.2-8/40 (Ex) 60 410 135 28.00 32.00 S1/S1 500 1413 985
T 30-8/29 (Ex) 42.5 220 73 20.00 23.00 S1/– 422 1035 781
T 30-8/35 (Ex) 48.5 270 90 24.00 27.50 S1/– 456 1095 841
T 30-8/45 (Ex) 67 360 119 31.50 36.00 S1/– 510 1185 931
T 30-8/57 (Ex) 85 450 149 40.00 45.50 S1/– 570 1295 1041
T 34-8/41 (Ex) 93 510 170 45.00 52.00 S1/– 581 1189 935
T 34-8/50 (Ex) 111 630 210 55.00 62.00 S1/– 647 1259 1005
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 34.1... NBR - - SiC/SiC, SiC/SiC
FKT 27.1... NBR - - SiC/SiC, SiC/SiC
FKT 27.2... NBR - - SiC/SiC, SiC/SiC
T 30... NBR - - SiC/SiC, SiC/SiC
T 34... NBR - - SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 34.1... - - • • • – ǽ -
FKT 27.1... ǽ ǽ • • ǽ • - •
FKT 27.2... ǽ ǽ • • ǽ • - •
T 30... ǽ ǽ • ǽ ǽ – ǽ ǽ
T 34... ǽ ǽ • ǽ ǽ – ǽ ǽ
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

246 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps DN 200 to DN 250

Dimensions Wilo-EMU FA 25.82Z (740 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

1400 x 1200

Wastewater transport
105
1172

105 135
ø42,4x2

99

120
120

270

640
340
378
60

25
2 300
AW

600
117

600
300
667

250

3
300

Dimension drawing Wilo-EMU FA - stationary dry well installation

22
> 420
M20
A

523
930

1100
600

1200
680
1

630
420
> 420

1073
585

468
857

1100
1200
> 1520
4

1184
1 = DN250 PN10 / ANSI B16.1, Class 125, Size 10; 2 = DN250 PN10; 3 = DN300 PN10 / ANSI B16.1, Class 125, Size 12; 4 = DN300 PN10

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 247
Wastewater transport
Submersible pumps DN 200 to DN 250

Pump curves, technical data Wilo-EMU FA 25.93D (740 rpm)

Pump curves Wilo-EMU FA 25.93D - 50 Hz - 740 rpm


Multi-channel impeller - Free ball passage: 80 mm
H/m

20
20%
40%
50%
18
60%

70%
16 75%

14 80%

12

10

8
70%

6
Ø 451
Ø 430
Ø 400 60%
4 Ø 380
Ø 365
4 Ø 336 Ø 350

0
0 200 400 600 800 1000 1200 Q/m³/h
0 50 100 150 200 250 300 350 Q/l/s
P2/kW

Ø 451
30
Ø 430
Ø 400
20
Ø 380
Ø 365
Ø 350
Ø 336
10

0
0 200 400 600 800 1000 1200 Q/m³/h
0 50 100 150 200 250 300 350 Q/l/s

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 25.93D 80 Multi-channel impeller 350
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

248 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps DN 200 to DN 250

Pump curves, technical data Wilo-EMU FA 25.93D (740 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-

Wastewater transport
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 34.1-8/29 64 335 111 30.00 34.50 S1/S1 635 1252 998
FK 34.1-8/33 74 390 129 35.00 40.00 S1/S1 667 1252 998
FKT 27.1-8/22 (Ex) 30 135 45 14.00 16.70 S1/S1 370 1246 820
FKT 27.1-8/28 (Ex) 38.5 175 59 18.00 21.50 S1/S1 390 1246 820
FKT 27.2-8/32 (Ex) 50 300 100 23.50 27.50 S1/S1 470 1413 985
FKT 27.2-8/40 (Ex) 60 410 135 28.00 32.00 S1/S1 500 1413 985
T 30-8/29 (Ex) 42.5 220 73 20.00 23.00 S1/– 422 1035 781
T 30-8/35 (Ex) 48.5 270 90 24.00 27.50 S1/– 456 1095 841
T 30-8/45 (Ex) 67 360 119 31.50 36.00 S1/– 510 1185 931
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 34.1... NBR - - SiC/SiC, SiC/SiC
FKT 27.1... NBR - - SiC/SiC, SiC/SiC
FKT 27.2... NBR - - SiC/SiC, SiC/SiC
T 30... NBR - - SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 34.1... - - • • • – ǽ -
FKT 27.1... ǽ ǽ • • ǽ • - •
FKT 27.2... ǽ ǽ • • ǽ • - •
T 30... ǽ ǽ • ǽ ǽ – ǽ ǽ
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 249
Wastewater transport
Submersible pumps DN 200 to DN 250

Dimensions Wilo-EMU FA 25.93D (740 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

1400 x 1200
105
1172
ø42,4x2 135

378 105

120
60

640
340
270
99 2
AW

120
137

25
300
600
250

600
567

3
178

180

Dimension drawing Wilo-EMU FA - stationary dry well installation

22
> 420

M20
A

523
930

1100
680

600

1200
1

> 420

630
420
1073
587

470
750

1100
1200
> 1520
4

1155
1 = DN250 PN10 / ANSI B16.1, Class 125, Size 10; 2 = DN250 PN10; 3 = DN300 PN10 / ANSI B16.1, Class 125, Size 12; 4 = DN300 PN10

250 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps DN 200 to DN 250

Pump curves, technical data Wilo-EMU FA 25.93D (950 rpm)

Pump curves Wilo-EMU FA 25.93D - 50 Hz - 950 rpm


Multi-channel impeller - Free ball passage: 80 mm
H/m

Wastewater transport
32
40%
50%
60%
28
70%

78%
24
82%

20

16

12
70%

Ø 451
8
60% Ø 430
Ø 380 Ø 400
4 Ø 365
Ø 350
Ø 336

0
0 200 400 600 800 1000 1200 1400 1600 Q/m³/h
0 50 100 150 200 250 300 350 400 450 Q/l/s
P2/kW

Ø 451
60

Ø 400 Ø 430
40 Ø 380
Ø 365
Ø 350
20 Ø 336

0
0 200 400 600 800 1000 1200 1400 1600 Q/m³/h
0 50 100 150 200 250 300 350 400 450 Q/l/s

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 25.93D 80 Multi-channel impeller 350
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 251
Wastewater transport
Submersible pumps DN 200 to DN 250

Pump curves, technical data Wilo-EMU FA 25.93D (950 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 34.1-6/29 95 450 149 47.50 56.00 S1/S1 635 1252 998
FK 34.1-6/33 109 495 164 55.00 64.00 S1/S1 667 1252 998
FK 34.1-6/42 129 610 205 65.00 75.00 S1/S1 715 1372 1118
FK 34.1-6/50 151 720 240 75.00 86.00 S1/S1 780 1452 1198
FK 34.1-6/60 181 860 285 90.00 103.00 S1/S1 860 1547 1293
FKT 27.2-6/32 (Ex) 61 440 150 30.00 35.50 S1/S1 470 1413 985
FKT 27.2-6/40 (Ex) 74 520 175 36.50 42.00 S1/S1 500 1413 985
T 30-6/28 (Ex) 60 330 109 30.00 34.00 S1/– 416 1035 781
T 30-6/35 (Ex) 75 410 136 37.50 42.50 S1/– 456 1095 841
T 30-6/41 (Ex) 88 480 159 44.00 49.50 S1/– 471 1185 931
T 30-6/48 (Ex) 102 580 192 52.00 58.00 S1/– 531 1295 1041
T 34-6/41 (Ex) 124 670 225 65.00 70.00 S1/– 581 1189 935
T 34-6/50 (Ex) 136 790 265 70.00 78.00 S1/– 647 1259 1005
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 34.1... NBR - - SiC/SiC, SiC/SiC
FKT 27.2... NBR - - SiC/SiC, SiC/SiC
T 30... NBR - - SiC/SiC, SiC/SiC
T 34... NBR - - SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 34.1... - - • • • – ǽ -
FKT 27.2... ǽ ǽ • • ǽ • - •
T 30... ǽ ǽ • ǽ ǽ – ǽ ǽ
T 34... ǽ ǽ • ǽ ǽ – ǽ ǽ
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

252 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps DN 200 to DN 250

Dimensions Wilo-EMU FA 25.93D (950 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

Wastewater transport
1400 x 1200
105
1172
ø42,4x2 135

378 105

120
60

640
340
270
99 2
AW

120
137

25
300
600
250

600
567

3
178

180

Dimension drawing Wilo-EMU FA - stationary dry well installation

22
> 420
M20
A

523
930

1100
680

600

1200
1

> 420

630
420
1073
587

470
735

1100
1200
> 1520
4

1184
1 = DN250 PN10 / ANSI B16.1, Class 125, Size 10; 2 = DN250 PN10; 3 = DN300 PN10 / ANSI B16.1, Class 125, Size 12; 4 = DN300 PN10

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 253
Wastewater transport
Submersible pumps DN 300 to DN 600

Series description Wilo-EMU FA 30... - 60...

Wilo-EMU FA 30... - 60...

y}Z
Design Technical data
Submersible sewage pump with various cooling systems • Mains connection: 3~400 V, 50 Hz
• Immersed operating mode: S1
Type key • Surfaced operating mode with self-cooling motor: S1
• Protection class: IP 68
Example: Wilo-EMU FA 60.83V + T 56-8/70G Ex • Max. fluid temperature: 3 - 40 °C, higher temperatures on request
Hydraulics: FA 60.83V • Sealing: With two mechanical seals or one block seal cartridge, de-
pending on the motor
FA Submersible sewage pump
• Free ball passage: 80 - 170 mm.
60 x10 = nominal diameter of the pressure port, e.g. • Permanently lubricated roller bearings
DN600 • Max. immersion depth: 20 m
83 Performance indicator
V Type of impeller Materials
• Housing parts: EN-GJL or EN-GJS
• Impeller: EN-GJL or EN-GJS
Motor: T 56-8/70G Ex • Static seals: NBR
• Sealing on pump side: SiC/SiC
T Motor version
• Sealing on motor side: NBR or SiC/SiC
56 Size • Shaft: Stainless steel 1.4021
8 Number of poles
70 x10 = package length [mm]
Equipment/function
• Heavy-duty version made of grey cast iron
G Sealing version • Self-cooling motors with 1- or 2-chamber system
Ex Ex-rated • Simple installation via suspension unit or pump base

Application Description/design
• Pumping of sewage with solid constituents in water treatment sys- Submersible sewage pump as submersible monobloc unit for station-
tems and pumping stations ary wet well and dry well installation.
• Local drainage and water control
• Industrial applications Hydraulics
The outlet on the pressure side is designed as horizontal flange con-
nection. The maximum possible dry matter content is 8%, depending
Special features/product advantages
on the hydraulics and impeller type.
• Operation in stationary wet well and dry well installation
• Submersible The following impeller shapes are used:
• Easy installation due to suspension unit or pump base • Two-channel impeller (Z)
• Special materials and coatings against abrasion and corrosion • Three-channel impeller (D)
• Longitudinally watertight cable lead-in (depending on motor) • Four-channel impeller (V)
• Adjustment of duty point by trimming the impeller
Each multi-channel hydraulic unit (Z, D, V) is equipped with a mobile
and stationary wear ring. These contribute long-term to ensuring the
uniform efficiency of the unit.

254 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps DN 300 to DN 600

Series description Wilo-EMU FA 30... - 60...

Motor • Special materials, e.g. Abrasite


Dry motors (T motors) give off their heat directly to the surrounding • Ceram coating C0, C1, C2, C3
fluid via the housing components and can be used in immersed state • Ex-rated to ATEX or FM
for permanent operation. Depending on the size, they can also be

Wastewater transport
used in non-immersed state for short-term or permanent operation. Scope of delivery
• Submersible sewage pump
The oil-filled motors (FK motors) and self-cooling dry motors (FKT • Cable length per customer request
motors) give off their heat to the pumped fluid via a built-in heat ex- • Accessories per customer request
changer. Therefore, these motors are suitable for permanent opera- • Operating and maintenance manual
tion in immersed and non-immersed condition or for dry well instal-
lation.
Accessories
All motors have a sealing chamber that protects the motor from fluid
• Suspension unit or pump base
ingress. It can be accessed from the outside and can be monitored
• Various pressure outlets
with an optional sealing chamber electrode.
• Chains
• Fixation sets with anchor bolts
All filling fluids used are potentially biodegradable and environmen-
• Switchgears, relays and plugs
tally safe.
Commissioning
The cable inlet on the T and FKT motors is longitudinally watertight. Operation with non-immersed motor
Cable lengths can be individually configured. The surfacing of self-cooling motors (FK, FKT motors) is permitted.

Sealing In dry motors (T-motor), it is possible to have the motor non-im-


Fluid-side and motor-side sealing is possible in the following ver- mersed for short periods if equipped with motor temperature moni-
sions depending on the motor type: toring with a temperature circuit, or with two temperature circuits
• Version G: Two independently operating mechanical seals when used in potentially explosive areas. The maximum running time
• Version K: Block seal cartridge with two independently operating me- with non-immersed motor depends on the medium and ambient
chanical seals temperatures. Therefore, it is not possible to provide exact informa-
tion about the operating mode and time (e.g. S2-15)!
Options
Dry-running protection
• Special voltages The hydraulic housing must always be immersed to prevent air from
• PTC thermistor sensor being drawn in. In the case of fluctuating fluid levels, the system
• Internal or external sealing chamber control should shut down automatically once the minimum water submer-
• Monitoring units for leakage and bearing temperature sion is reached.

H/m
Wilo-EMU FA... DN300 ... DN600
100

70 DN300
60
50
40
30
DN350
20 DN400

DN600

10
DN500

1
1 10 100 200 300 500 1000 2000 Q/l/s

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 255
Wastewater transport
Submersible pumps DN 300 to DN 600

Pump curves, technical data Wilo-EMU FA 30.78D (740 rpm)

Pump curves Wilo-EMU FA 30.78D - 50 Hz - 740 rpm


Multi-channel impeller - Free ball passage: 100 mm

H[m]

50
40%
50%
60%
45
68%
72%
75%
40 77%
79%
80%
35

30
Ø 740
25
Ø 720
20 Ø 705
72% Ø 691
68%
Ø 675
15 Ø 660
Ø 645
60% Ø 615
10
Ø 585
5

0
0 200 400 600 800 1000 1200 1400 1600 1800 Q[m³/h]

0 100 200 300 400 500 Q[l/s]

P2[kW]

Ø 740
Ø 720
Ø 705
120 Ø 691
Ø 675
Ø 645 Ø 660
80 Ø 615
Ø 585
40

0
0 200 400 600 800 1000 1200 1400 1600 1800 Q[m³/h]

0 100 200 300 400 500 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 30.78D 100 Multi-channel impeller 640
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

256 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps DN 300 to DN 600

Pump curves, technical data Wilo-EMU FA 30.78D (740 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-

Wastewater transport
immersed)
IN IA P2 P1 A AW
A kW kg mm
FKT 56-8/53 (Ex) 375 2200 740 195.0 205.0 S1/S1 2450 2241 1431
FKT 50.1-8/38 185 970 320 90.0 98.0 S1/S1 2201 2217 1333
FKT 50.1-8/45 225 1160 390 110.0 119.0 S1/S1 2325 2317 1433
FKT 50.1-8/54 270 1440 480 132.0 142.0 S1/S1 2484 2407 1523
FKT 50.1-8/62 335 1720 580 165.0 177.0 S1/S1 2590 2407 1523
T 50.1-8/38 220 980 325 110.0 119.0 S1/– 1866 2217 1333
T 50.1-8/45 260 1170 390 132.0 142.0 S1/– 1980 2317 1433
T 50.1-8/54 325 1600 540 165.0 177.0 S1/– 2131 2407 1523
T 50.1-8/62 390 1740 580 195.0 210.0 S1/– 2237 2407 1523
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FKT 56... NBR - SiC/SiC, SiC/SiC -
FKT 50.1… NBR - SiC/SiC, SiC/SiC -
T 50.1… NBR - SiC/SiC, SiC/SiC -

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FKT 56... ǽ • • • ǽ • ǽ •
FKT 50.1… ǽ ǽ • • – • ǽ •
T 50.1… ǽ ǽ • • • • ǽ •
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 257
Wastewater transport
Submersible pumps DN 300 to DN 600

Dimensions Wilo-EMU FA 30.78D (740 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

1700 x
1300 150

ø88,9x4,05 434
26
1472
150
112 359

200

920
400
410
200
114
AW

1
600
153

1060
675
748
286

325
270

Dimension drawing Wilo-EMU FA - stationary dry well installation

22
A

> 420

595
1113

1
1170
670

1090

800
> 420
439

1360
620
789

2
700
> 1040
3

1300

1 = DN300 PN10 / ANSI B16.1, Class 125, Size 12; 2 = DN400 PN10 / ANSI B16.1, Class 125, Size 16; 3 = DN400 PN10

258 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps DN 300 to DN 600

Pump curves, technical data Wilo-EMU FA 30.78D (950 rpm)

Pump curves Wilo-EMU FA 30.78D - 50 Hz - 950 rpm


Multi-channel impeller - Free ball passage: 100 mm

H[m]

Wastewater transport
90

80 40%
50%
60%
70%
70
74%
77%
79%
60

50
Ø 740
Ø 720
40
Ø 705
Ø 691
Ø 675
30
70% Ø 660
Ø 645
20
60%
Ø 615
10
Ø 585

0
0 400 800 1200 1600 2000 Q[m³/h]

0 100 200 300 400 500 600 Q[l/s]

P2[kW]
Ø 740
300 Ø 720
Ø 705
Ø 691
Ø 675
Ø 660
200 Ø 645
Ø 615
Ø 585
100

0
0 400 800 1200 1600 2000 Q[m³/h]

0 100 200 300 400 500 600 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 30.78D 100 Multi-channel impeller 640
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 259
Wastewater transport
Submersible pumps DN 300 to DN 600

Pump curves, technical data Wilo-EMU FA 30.78D (950 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-
immersed)
IN IA P2 P1 A AW
A kW kg mm
T 50.1-6/50 315 1960 660 170.0 180.0 S1/– 2053 2317 1433
T 50.1-6/55 380 2280 760 205.0 220.0 S1/– 2144 2406 1523
T 50.1-6/59 410 2560 860 225.0 240.0 S1/– 2197 2407 1523
T 50.1-6/62 460 2670 890 250.0 265.0 S1/– 2237 2407 1523
T 56-6/53 (Ex) 510 2800 930 285.0 300.0 S1/– 2190 2196 1386
T 56-6/58 (Ex) 550 3100 1030 310.0 325.0 S1/– 2370 2196 1386
T 56-6/64 (Ex) 610 3600 1200 340.0 355.0 S1/– 2580 2316 1506
T 56-6/70 (Ex) 660 4050 1360 375.0 390.0 S1/– 2860 2316 1506
T 56-6/78 (Ex) 740 3880 1270 420.0 435.0 S1/– 3080 2416 1606
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
T 50.1… NBR - SiC/SiC, SiC/SiC -
T 56... NBR - SiC/SiC, SiC/SiC -

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
T 50.1… ǽ ǽ • • • • ǽ •
T 56... ǽ ǽ • • • – ǽ ǽ
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

260 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps DN 300 to DN 600

Dimensions Wilo-EMU FA 30.78D (950 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

1700 x

Wastewater transport
1300 150

ø88,9x4,05 434
26
1472
150
112 359

200

800
400
410
200
114
AW

1
600
153

1000
675
748
286

325
270

1 = DN300 PN10 / ANSI B16.1, Class 125, Size 12; 2 = DN400 PN10 / ANSI B16.1, Class 125, Size 16; 3 = DN400 PN10

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 261
Wastewater transport
Submersible pumps DN 300 to DN 600

Pump curves, technical data Wilo-EMU FA 30.78D (950 rpm)

Pump curves Wilo-EMU FA 30.78D - 50 Hz - 950 rpm


Multi-channel impeller - Free ball passage: 100 mm

H[m]
90

40%
80
50%
60%
70%
70
74%
77%
79%
60

50
Ø 740
Ø 720
40
Ø 705
Ø 691
Ø 675
30
70% Ø 660
Ø 645
20
60%
Ø 615

10
Ø 585

0
0 400 800 1200 1600 2000 Q[m³/h]

0 100 200 300 400 500 600 Q[l/s]

P2[kW]
Ø 740
300 Ø 720
Ø 705
Ø 691
Ø 675
Ø 660
200 Ø 645
Ø 615
Ø 585
100

0
0 400 800 1200 1600 2000 Q[m³/h]

0 100 200 300 400 500 600 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 30.78D 100 Multi-channel impeller 640
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

262 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps DN 300 to DN 600

Pump curves, technical data Wilo-EMU FA 30.78D (950 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-

Wastewater transport
immersed)
IN IA P2 P1 A AW
A kW kg mm
FKT 50.1-6/55 310 1860 620 170.0 180.0 S1/S1 2497 2407 1523
FKT 50.1-6/59 340 2060 690 185.0 196.0 S1/S1 2550 2407 1523
FKT 50.1-6/62 370 2360 790 205.0 220.0 S1/S1 2590 2407 1523
FKT 56-6/53 (Ex) 410 2800 940 225.0 245.0 S1/S1 2450 2241 1431
FKT 56-6/58 (Ex) 455 3100 1040 250.0 270.0 S1/S1 2630 2241 1431
FKT 56-6/64 (Ex) 520 3400 1140 285.0 305.0 S1/S1 2840 2361 1551
FKT 56-6/70 (Ex) 560 4000 1340 310.0 325.0 S1/S1 3120 2361 1551
FKT 56-6/78 (Ex) 640 4540 1520 340.0 370.0 S1/S1 3340 2441 1631
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FKT 50.1… NBR - SiC/SiC, SiC/SiC -
FKT 56... NBR - SiC/SiC, SiC/SiC -

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FKT 50.1… ǽ ǽ • • – • ǽ •
FKT 56... ǽ • • • ǽ • ǽ •
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 263
Wastewater transport
Submersible pumps DN 300 to DN 600

Dimensions Wilo-EMU FA 30.78D (950 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

1700 x
1300 150

ø88,9x4,05 434
26
1472
150
112 359

200

800
400
410
200
114
AW

1
600
153

1000
675
748
286

325
270

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

595
1113
22

1170
1090

620 800
439

700 1360
789

2
3

1300

1 = DN300 PN10 / ANSI B16.1, Class 125, Size 12; 2 = DN400 PN10 / ANSI B16.1, Class 125, Size 16; 3 = DN400 PN10

264 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps DN 300 to DN 600

Pump curves, technical data Wilo-EMU FA 30.93D (950 rpm)

Pump curves Wilo-EMU FA 30.93D - 50 Hz - 950 rpm


Multi-channel impeller - Free ball passage: 80 mm

H[m]

Wastewater transport
32
40%
60%
28
70%
75%

24 80%

20

16

12
70%

8 60%

4 Ø 400 Ø 451
Ø 380 Ø 430
Ø 336 Ø 350 Ø 365

0
0 400 800 1200 1600 2000 Q[m³/h]

0 100 200 300 400 500 600 Q[l/s]

P2[kW]

60
Ø 451
Ø 430
40 Ø 400
Ø 380
Ø 365
Ø 350
20 Ø 336

0
0 400 800 1200 1600 2000 Q[m³/h]

0 100 200 300 400 500 600 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 30.93D 80 Multi-channel impeller 340
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 265
Wastewater transport
Submersible pumps DN 300 to DN 600

Pump curves, technical data Wilo-EMU FA 30.93D (950 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 34.1-6/29 95 450 149 47.5 56.0 S1/S1 635 1252 998
FK 34.1-6/33 109 495 164 55.0 64.0 S1/S1 667 1252 998
FK 34.1-6/42 129 610 205 65.0 75.0 S1/S1 715 1372 1118
FK 34.1-6/50 151 720 240 75.0 86.0 S1/S1 780 1452 1198
FK 34.1-6/60 181 860 285 90.0 103.0 S1/S1 860 1547 1293
FKT 27.2-6/32 (Ex) 61 440 150 30.0 35.5 S1/S1 470 1413 985
FKT 27.2-6/40 (Ex) 74 520 175 36.5 42.0 S1/S1 500 1413 985
T 30-6/28 (Ex) 60 330 109 30.0 34.0 S1/– 416 1035 781
T 30-6/35 (Ex) 75 410 136 37.5 42.5 S1/– 456 1095 841
T 30-6/41 (Ex) 88 480 159 44.0 49.5 S1/– 471 1185 931
T 30-6/48 (Ex) 102 580 192 52.0 58.0 S1/– 531 1295 1041
T 34-6/29 (Ex) 85 490 162 45.0 49.0 S1/– 494 1109 855
T 34-6/32 (Ex) 94 540 179 50.0 55.0 S1/– 537 1109 855
T 34-6/41 (Ex) 124 670 225 65.0 70.0 S1/– 581 1189 935
T 34-6/50 (Ex) 136 790 265 70.0 78.0 S1/– 647 1259 1005
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 34.1... NBR - - SiC/SiC, SiC/SiC
FKT 27.2... NBR - - SiC/SiC, SiC/SiC
T 30... NBR - - SiC/SiC, SiC/SiC
T 34... NBR - - SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 34.1... - - • • • – ǽ -
FKT 27.2... ǽ ǽ • • ǽ • - •
T 30... ǽ ǽ • ǽ ǽ – ǽ ǽ
T 34... ǽ ǽ • ǽ ǽ – ǽ ǽ
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

266 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps DN 300 to DN 600

Dimensions Wilo-EMU FA 30.93D (950 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

Wastewater transport
1500 x 1200
150
1222
434
26
ø88,9x4,05
150

200

800
400
410
200
112 359
114
AW

1 600
117

1000
675
602

325
178

1
160

Dimension drawing Wilo-EMU FA - stationary dry well installation

> 420 22

M20

1100
523

680

600

1200
930
A

> 420

420

680 1100
1123 1200
587

> 1520
470
750
2

1205
1 = DN300 PN10 / ANSI B16.1, Class 125, Size 12; 2 = DN300PN10

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 267
Wastewater transport
Submersible pumps DN 300 to DN 600

Pump curves, technical data Wilo-EMU FA 40.75Z (740 rpm)

Pump curves Wilo-EMU FA 40.75Z - 50 Hz - 740 rpm


Multi-channel impeller - Free ball passage: 170 mm

H[m]

20%
24
40%
50%

20 60%

70%

16

12

76%

8
70%

Ø 560
Ø 500 Ø 530
4

0
0 400 800 1200 1600 2000 Q[m³/h]

0 100 200 300 400 500 600 Q[l/s]

P2[kW]

60
Ø 560
40
Ø 530
Ø 500
20

0
0 400 800 1200 1600 2000 Q[m³/h]

0 100 200 300 400 500 600 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 40.75Z 170 Multi-channel impeller 1025
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

268 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps DN 300 to DN 600

Pump curves, technical data Wilo-EMU FA 40.75Z (740 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-

Wastewater transport
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 34.1-8/42 94 500 165 45.0 51.0 S1/S1 715 1372 1118
FK 34.1-8/50 115 600 198 55.0 62.0 S1/S1 780 1452 1198
FK 34.1-8/60 134 700 235 65.0 73.0 S1/S1 860 1547 1293
FK 42.1-8/40 151 790 265 75.0 86.0 S1/S1 1235 1512 1195
T 30-8/57 (Ex) 85 450 149 40.0 45.5 S1/– 570 1295 1041
T 34-8/41 (Ex) 93 510 170 45.0 52.0 S1/– 581 1189 935
T 34-8/50 (Ex) 111 630 210 55.0 62.0 S1/– 647 1259 1005
T 42-8/34 131 680 225 65.0 73.0 S1/– 1010 1607 1107
T 42-8/40 151 780 260 75.0 84.0 S1/– 1060 1707 1207
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 34.1... NBR - - SiC/SiC, SiC/SiC
FK 42.1... NBR - SiC/SiC, SiC/SiC -
T 34... NBR - - SiC/SiC, SiC/SiC
T 42... NBR - SiC/SiC, SiC/SiC -

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 34.1... - - • • • – ǽ -
FK 42.1... - - • • • – ǽ -
T 34... ǽ ǽ • ǽ ǽ – ǽ ǽ
T 42... ǽ - • ǽ ǽ – ǽ ǽ
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 269
Wastewater transport
Submersible pumps DN 300 to DN 600

Dimensions Wilo-EMU FA 40.75Z (740 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

2000 x 1800
160
499

26
ø60,3x3,65
1709 160

144 426

1000
AW

200

520

620
300

200
90
1
297

730
810

1100
1097

380
400

420

Dimension drawing Wilo-EMU FA - stationary dry well installation

900
780
812
1400
673

1100
980

1
1026

2
900
27
1565
3

1500

1 = DN400 PN10 / ANSI B16.1, Class 125, Size 16; 2 = DN500 PN10 / ANSI B16.1, Class 125, Size 20; 3 = DN500 PN10

270 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps DN 300 to DN 600

Pump curves, technical data Wilo-EMU FA 40.75Z (950 rpm)

Pump curves Wilo-EMU FA 40.75Z - 50 Hz - 950 rpm


Multi-channel impeller - Free ball passage: 170 mm

H[m]

Wastewater transport
40
20%

35 40%
50%
60%

30
70%
75%
25

20

15

70%
10
Ø 548
Ø 530
Ø 500
5

0
0 400 800 1200 1600 2000 2400 2800 Q[m³/h]

0 100 200 300 400 500 600 700 800 Q[l/s]

P2[kW]

120
Ø 548
80
Ø 530
Ø 500
40

0
0 400 800 1200 1600 2000 2400 2800 Q[m³/h]

0 100 200 300 400 500 600 700 800 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 40.75Z 170 Multi-channel impeller 1025
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 271
Wastewater transport
Submersible pumps DN 300 to DN 600

Pump curves, technical data Wilo-EMU FA 40.75Z (950 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 34.1-6/60 181 860 285 90.0 103.0 S1/S1 860 1547 1293
FK 42.1-6/46 235 1270 420 110.0 125.0 S1/S1 1300 1512 1195
FK 42.1-6/50 280 1490 495 132.0 149.0 S1/S1 1345 1667 1350
FK 42.1-6/60 320 1680 560 150.0 169.0 S1/S1 1540 1667 1350
FKT 50.1-6/50 245 1510 500 135.0 143.0 S1/S1 2397 2317 1433
FKT 50.1-6/55 310 1860 620 170.0 180.0 S1/S1 2497 2407 1523
T 42-6/36 182 910 305 90.0 98.0 S1/– 1020 1607 1107
T 42-6/46 220 1100 365 110.0 120.0 S1/– 1120 1707 1207
T 42-6/52 270 1330 445 132.0 144.0 S1/– 1180 1757 1257
T 50.1-6/50 315 1960 660 170.0 180.0 S1/– 2053 2317 1433
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 34.1... NBR - - SiC/SiC, SiC/SiC
FK 42.1... NBR - SiC/SiC, SiC/SiC -
FKT 50.1… NBR - SiC/SiC, SiC/SiC -
T 42... NBR - SiC/SiC, SiC/SiC -
T 50.1… NBR - SiC/SiC, SiC/SiC -

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 34.1... - - • • • – ǽ -
FK 42.1... - - • • • – ǽ -
FKT 50.1… ǽ ǽ • • – • ǽ •
T 42... ǽ - • ǽ ǽ – ǽ ǽ
T 50.1… ǽ ǽ • • • • ǽ •
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

272 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps DN 300 to DN 600

Dimensions Wilo-EMU FA 40.75Z (950 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

2000 x 1800

Wastewater transport
160
499

26
ø60,3x3,65
1709 160

144 426

1000
AW

200

520

620
300

200
90
1
250

810

730
1100
1050

400

380
420

Dimension drawing Wilo-EMU FA - stationary dry well installation

900
780
812
1400
673

1100
980

1
1026

2
900
27
1565
3

1500

1 = DN400 PN10 / ANSI B16.1, Class 125, Size 16; 2 = DN500 PN10 / ANSI B16.1, Class 125, Size 20; 3 = DN500 PN10

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 273
Wastewater transport
Submersible pumps DN 300 to DN 600

Pump curves, technical data Wilo-EMU FA 50.21D (585 rpm)

Pump curves Wilo-EMU FA 50.21D - 50 Hz - 585 rpm


Multi-channel impeller - Free ball passage: 130 mm

H[m]

14

12

10

2 Ø 430 Ø 486

0
0 400 800 1200 1600 2000 2400 2800 Q[m³/h]

0 100 200 300 400 500 600 700 800 Q[l/s]

P2[kW]

60

40
Ø 486

20 Ø 430

0
0 400 800 1200 1600 2000 2400 2800 Q[m³/h]

0 100 200 300 400 500 600 700 800 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 50.21D 130 Multi-channel impeller 1237
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

274 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps DN 300 to DN 600

Pump curves, technical data Wilo-EMU FA 50.21D (585 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-

Wastewater transport
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 34.1-10/29 64 375 124 27.5 32.5 S1/S1 635 1252 998
FK 34.1-10/33 79 475 157 35.0 41.0 S1/S1 667 1252 998
FK 34.1-10/50 111 660 220 50.0 58.0 S1/S1 780 1452 1198
T 34-10/29 (Ex) 64 350 116 27.5 32.5 S1/– 494 1109 855
T 34-10/35 (Ex) 87 450 149 38.0 43.5 S1/– 537 1109 855
T 34-10/49 (Ex) 116 580 192 50.0 58.0 S1/– 647 1259 1005
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 34.1... NBR - - SiC/SiC, SiC/SiC
T 34... NBR - - SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 34.1... - - • • • – ǽ -
T 34... ǽ ǽ • ǽ ǽ – ǽ ǽ
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 275
Wastewater transport
Submersible pumps DN 300 to DN 600

Dimensions Wilo-EMU FA 50.21D (585 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

2000 x
1800 *

* *
*
*
*
* *

*
*

*
*
AW

1
*
278

*
1000
1228
450

450
500

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

807
18

1345
1300
1180

1
786

830
1200 950
1211

2 1595
3

1650

1 = DN500 PN10 / ANSI B16.1, Class 125, Size 20; 2 = DN600 PN10 / ANSI B16.1, Class 125, Size 24; 3 = DN600 PN10; * = on request

276 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps DN 300 to DN 600

Pump curves, technical data Wilo-EMU FA 50.21D (740 rpm)

Pump curves Wilo-EMU FA 50.21D - 50 Hz - 740 rpm


Multi-channel impeller - Free ball passage: 130 mm

H[m]

Wastewater transport
20

18

16

14

12

10

4
Ø 486
Ø 430
2

0
0 500 1000 1500 2000 2500 3000 3500 Q[m³/h]

0 200 400 600 800 1000 Q[l/s]

P2[kW]

120

80

Ø 486
Ø 430
40

0
0 500 1000 1500 2000 2500 3000 3500 Q[m³/h]

0 200 400 600 800 1000 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 50.21D 130 Multi-channel impeller 1237
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 277
Wastewater transport
Submersible pumps DN 300 to DN 600

Pump curves, technical data Wilo-EMU FA 50.21D (740 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-
immersed)
IN IA P2 P1 A AW
A kW kg mm
FK 34.1-8/50 115 600 198 55.0 62.0 S1/S1 780 1452 1198
FK 34.1-8/60 134 700 235 65.0 73.0 S1/S1 860 1547 1293
FK 42.1-8/40 151 790 265 75.0 86.0 S1/S1 1235 1512 1195
FK 42.1-8/50 181 950 315 90.0 103.0 S1/S1 1345 1667 1350
T 34-8/50 (Ex) 111 630 210 55.0 62.0 S1/– 647 1259 1005
T 42-8/34 131 680 225 65.0 73.0 S1/– 1010 1607 1107
T 42-8/40 151 780 260 75.0 84.0 S1/– 1060 1707 1207
T 42-8/50 179 920 305 90.0 99.0 S1/– 1160 1757 1257
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FK 34.1... NBR - - SiC/SiC, SiC/SiC
FK 42.1... NBR - SiC/SiC, SiC/SiC -
T 34... NBR - - SiC/SiC, SiC/SiC
T 42... NBR - SiC/SiC, SiC/SiC -

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FK 34.1... - - • • • – ǽ -
FK 42.1... - - • • • – ǽ -
T 34... ǽ ǽ • ǽ ǽ – ǽ ǽ
T 42... ǽ - • ǽ ǽ – ǽ ǽ
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

278 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps DN 300 to DN 600

Dimensions Wilo-EMU FA 50.21D (740 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

2000 x

Wastewater transport
1800 *

* *
*
*
*
* *

*
*

*
*
AW

1
*
278

*
1000
1228
450

450
500

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

807
18

1345
1300
1180

1
786

830
1200 950
1211

2 1595
3

1650

1 = DN500 PN10 / ANSI B16.1, Class 125, Size 20; 2 = DN600 PN10 / ANSI B16.1, Class 125, Size 24; 3 = DN600 PN10; * = on request

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 279
Wastewater transport
Submersible pumps DN 300 to DN 600

Pump curves, technical data Wilo-EMU FA 50.98V (585 rpm)

Pump curves Wilo-EMU FA 50.98V - 50 Hz - 585 rpm


Multi-channel impeller - Free ball passage: 100 mm

H[m]

24

50%
60%
20
70%

16
80%

84%
12

8
84%
80%
Ø 690
4
Ø 635

Ø 580
0
0 500 1000 1500 2000 2500 3000 3500 Q[m³/h]

0 200 400 600 800 1000 Q[l/s]

P2[kW]

120

80
Ø 690
40 Ø 635

Ø 580
0
0 500 1000 1500 2000 2500 3000 3500 Q[m³/h]

0 200 400 600 800 1000 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 50.98V 100 Multi-channel impeller 1940
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

280 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps DN 300 to DN 600

Pump curves, technical data Wilo-EMU FA 50.98V (585 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-

Wastewater transport
immersed)
IN IA P2 P1 A AW
A kW kg mm
FKT 50.1-10/37 162 760 251 75.0 82.0 S1/S1 2184 2217 1333
FKT 50.1-10/46 215 970 320 100.0 109.0 S1/S1 2339 2317 1433
FKT 50.1-10/58 255 1220 410 120.0 130.0 S1/S1 2530 2406 1523
FKT 50.1-10/62 280 1300 440 132.0 143.0 S1/S1 2582 2406 1523
T 50.1-10/37 197 760 260 95.0 104.0 S1/– 1849 2217 1333
T 50.1-10/46 250 980 330 120.0 131.0 S1/– 1994 2317 1433
T 50.1-10/58 300 1240 420 145.0 157.0 S1/– 2176 2407 1523
T 50.1-10/62 330 1320 440 160.0 173.0 S1/– 2229 2407 1523
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FKT 50.1… NBR - SiC/SiC, SiC/SiC -
T 50.1… NBR - SiC/SiC, SiC/SiC -

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FKT 50.1… ǽ ǽ • • – • ǽ •
T 50.1… ǽ ǽ • • • • ǽ •
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 281
Wastewater transport
Submersible pumps DN 300 to DN 600

Dimensions Wilo-EMU FA 50.98V (585 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

2200 x
2000 *

*
* *
*
*
* *

*
*

*
*
AW

1
*
230

*
1000
573
1310

450
630

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

868
26

1600
1480

1530

1060 1050
730

1200 1806
1203

2
3

1750

1 = DN500 PN10 / ANSI B16.1, Class 125, Size 20; 2 = DN600 PN10 / ANSI B16.1, Class 125, Size 24; 3 = DN600 PN10; * = on request

282 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps DN 300 to DN 600

Pump curves, technical data Wilo-EMU FA 50.98V (740 rpm)

Pump curves Wilo-EMU FA 50.98V - 50 Hz - 740 rpm


Multi-channel impeller - Free ball passage: 100 mm

H[m]

Wastewater transport
40
20%
40%
50%
35
60%
70%
30
80%

25

20

80%
15

70%
10
Ø 690

Ø 635
5
Ø 580

0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 Q[m³/h]

0 200 400 600 800 1000 1200 Q[l/s]

P2[kW]

150 Ø 690
Ø 635
100

50 Ø 580

0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 Q[m³/h]

0 200 400 600 800 1000 1200 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 50.98V 100 Multi-channel impeller 1940
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 283
Wastewater transport
Submersible pumps DN 300 to DN 600

Pump curves, technical data Wilo-EMU FA 50.98V (740 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-
immersed)
IN IA P2 P1 A AW
A kW kg mm
FKT 50.1-8/54 270 1440 480 132.0 142.0 S1/S1 2484 2407 1523
FKT 50.1-8/62 335 1720 580 165.0 177.0 S1/S1 2590 2407 1523
FKT 56-8/53 (Ex) 375 2200 740 195.0 205.0 S1/S1 2450 2241 1431
FKT 56-8/58 (Ex) 405 2450 820 210.0 230.0 S1/S1 2630 2241 1431
FKT 56-8/64 (Ex) 445 2700 900 230.0 250.0 S1/S1 2840 2361 1551
FKT 56-8/70 (Ex) 490 2950 990 255.0 275.0 S1/S1 3120 2361 1551
T 50.1-8/45 260 1170 390 132.0 142.0 S1/– 1980 2317 1433
T 50.1-8/54 325 1600 540 165.0 177.0 S1/– 2131 2407 1523
T 50.1-8/62 390 1740 580 195.0 210.0 S1/– 2237 2407 1523
T 56-8/53 (Ex) 435 2200 730 230.0 245.0 S1/– 2190 2196 1386
T 56-8/58 (Ex) 480 2450 820 255.0 270.0 S1/– 2370 2196 1386
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FKT 50.1… NBR - SiC/SiC, SiC/SiC -
FKT 56... NBR - SiC/SiC, SiC/SiC -
T 50.1… NBR - SiC/SiC, SiC/SiC -
T 56... NBR - SiC/SiC, SiC/SiC -

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FKT 50.1… ǽ ǽ • • – • ǽ •
FKT 56... ǽ • • • ǽ • ǽ •
T 50.1… ǽ ǽ • • • • ǽ •
T 56... ǽ ǽ • • • – ǽ ǽ
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

284 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps DN 300 to DN 600

Dimensions Wilo-EMU FA 50.98V (740 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

2200 x

Wastewater transport
2000 *

*
* *
*
*
* *

*
*

*
*
AW

1
*
230

*
1000
573
1310

450
630

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

868
26

1600
1480

1530

1060 1050
730

1200 1806
1203

2
3

1750

1 = DN500 PN10 / ANSI B16.1, Class 125, Size 20; 2 = DN600 PN10 / ANSI B16.1, Class 125, Size 24; 3 = DN600 PN10; * = on request

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 285
Wastewater transport
Submersible pumps DN 300 to DN 600

Pump curves, technical data Wilo-EMU FA 50.98V (950 rpm)

Pump curves Wilo-EMU FA 50.98V - 50 Hz - 950 rpm


Multi-channel impeller - Free ball passage: 100 mm

H[m]

70
30%
40%
60 50%

60%

50
70%

75%
40

30
70%

20 60%

Ø 690
Ø 635
10 Ø 580

0
0 1000 2000 3000 4000 5000 6000 Q[m³/h]

0 200 400 600 800 1000 1200 1400 1600 1800 Q[l/s]

P2[kW]

Ø 690
400
Ø 635
300 Ø 580

200

100

0
0 1000 2000 3000 4000 5000 6000 Q[m³/h]

0 200 400 600 800 1000 1200 1400 1600 1800 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 50.98V 100 Multi-channel impeller 1940
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

286 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps DN 300 to DN 600

Pump curves, technical data Wilo-EMU FA 50.98V (950 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-

Wastewater transport
immersed)
IN IA P2 P1 A AW
A kW kg mm
FKT 56-6/70 (Ex) 560 4000 1340 310.0 325.0 S1/S1 3120 2361 1551
FKT 56-6/78 (Ex) 640 4540 1520 340.0 370.0 S1/S1 3340 2441 1631
FKT 72-6/54 760 5300 1740 420.0 450.0 S1/S1 5220 2323 1707
FKT 72-6/60 820 5700 1890 450.0 480.0 S1/S1 5560 2383 1767
FKT 72-6/66 910 6400 2140 500.0 540.0 S1/S1 5850 2523 1907
FKT 72-6/73 980 7100 2350 540.0 580.0 S1/S1 6180 2523 1907
FKT 72-6/80 1100 7700 2550 610.0 650.0 S1/S1 6520 2593 1977
T 56-6/58 (Ex) 550 3100 1030 310.0 325.0 S1/– 2370 2196 1386
T 56-6/64 (Ex) 610 3600 1200 340.0 355.0 S1/– 2580 2316 1506
T 56-6/70 (Ex) 660 4050 1360 375.0 390.0 S1/– 2860 2316 1506
T 56-6/78 (Ex) 740 3880 1270 420.0 435.0 S1/– 3080 2416 1606
T 72-6/54 880 5300 1740 500.0 520.0 S1/– 4210 2615 1790
T 72-6/66 1080 6400 2150 610.0 640.0 S1/– 4595 2755 1930
T 72-6/73 1180 7120 2380 670.0 700.0 S1/– 4820 2755 1930
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FKT 56... NBR - SiC/SiC, SiC/SiC -
FKT 72... NBR - SiC/SiC, SiC/SiC -
T 56... NBR - SiC/SiC, SiC/SiC -
T 72... NBR - SiC/SiC, SiC/SiC -

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FKT 56... ǽ • • • ǽ • ǽ •
FKT 72... - - • • ǽ • • •
T 56... ǽ ǽ • • • – ǽ ǽ
T 72... - - • • • – • ǽ
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 287
Wastewater transport
Submersible pumps DN 300 to DN 600

Dimensions Wilo-EMU FA 50.98V (950 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

2200 x
2000 *

*
* *
*
*
* *

*
*

*
*
AW

1
*
230

*
1000
573
1310

450
630

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

868
26

1600
1480

1530

1060 1050
730

1200 1806
1203

2
3

1750

1 = DN500 PN10 / ANSI B16.1, Class 125, Size 20; 2 = DN600 PN10 / ANSI B16.1, Class 125, Size 24; 3 = DN600 PN10; * = on request

288 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps DN 300 to DN 600

Pump curves, technical data Wilo-EMU FA 50.98D (585 rpm)

Pump curves Wilo-EMU FA 50.98D - 50 Hz - 585 rpm


Multi-channel impeller - Free ball passage: 100 mm

H/m

Wastewater transport
24

70%
75%
20
80%

85%

16

85%
12
80%
75%
8 70%

4 Ø 700
Ø 680
Ø 640 Ø 660
Ø 600 Ø 620

0
0 500 1000 1500 2000 2500 3000 3500 4000 Q/m³/h
0 200 400 600 800 1000 Q/l/s

P2/kW
120

Ø 700
80 Ø 680
Ø 660
Ø 640
Ø 620
40 Ø 600

0
0 500 1000 1500 2000 2500 3000 3500 4000 Q/m³/h

0 200 400 600 800 1000 Q/l/s

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 50.98D 120 Multi-channel impeller 2350
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 289
Wastewater transport
Submersible pumps DN 300 to DN 600

Pump curves, technical data Wilo-EMU FA 50.98D (585 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-
immersed)
IN IA P2 P1 A AW
A kW kg mm
FKT 50.1-10/37 162 760 251 75.0 82.0 S1/S1 2184 2217 1333
FKT 50.1-10/46 215 970 320 100.0 109.0 S1/S1 2339 2317 1433
FKT 50.1-10/58 255 1220 410 120.0 130.0 S1/S1 2530 2406 1523
FKT 50.1-10/62 280 1300 440 132.0 143.0 S1/S1 2582 2406 1523
T 50.1-10/37 197 760 260 95.0 104.0 S1/– 1849 2217 1333
T 50.1-10/46 250 980 330 120.0 131.0 S1/– 1994 2317 1433
T 50.1-10/58 300 1240 420 145.0 157.0 S1/– 2176 2407 1523
T 50.1-10/62 330 1320 440 160.0 173.0 S1/– 2229 2407 1523
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FKT 50.1… NBR - SiC/SiC, SiC/SiC -
T 50.1… NBR - SiC/SiC, SiC/SiC -

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FKT 50.1… ǽ ǽ • • – • ǽ •
T 50.1… ǽ ǽ • • • • ǽ •
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

290 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps DN 300 to DN 600

Dimensions Wilo-EMU FA 50.98D (585 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

2200 x

Wastewater transport
2000 *

*
* *
*
*
* *

*
*

*
*
AW

1
*
230

*
1000
573
1310

450
630

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

868
26

1600
1480

1530

1060 1050
730

1200 1806
1203

2
3

1750

1 = DN500 PN10 / ANSI B16.1, Class 125, Size 20; 2 = DN600 PN10 / ANSI B16.1, Class 125, Size 24; 3 = DN600 PN10; * = on request

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 291
Wastewater transport
Submersible pumps DN 300 to DN 600

Pump curves, technical data Wilo-EMU FA 50.98D (740 rpm)

Pump curves Wilo-EMU FA 50.98D - 50 Hz - 740 rpm


Multi-channel impeller - Free ball passage: 100 mm

H/m

40

60%
35 70%
75%
80%
30 85%

25

85%
20
80%

15 75%

70%
Ø 700
10
Ø 680
Ø 660
5 Ø 640
Ø 620
Ø 600
0
0 1000 2000 3000 4000 5000 Q/m³/h

0 200 400 600 800 1000 1200 1400 Q/l/s


P2/kW

Ø 700
200
Ø 680
150 Ø 660
Ø 640
100 Ø 620
Ø 600
50

0
0 1000 2000 3000 4000 5000 Q/m³/h

0 200 400 600 800 1000 1200 1400 Q/l/s

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 50.98D 120 Multi-channel impeller 2350
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

292 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps DN 300 to DN 600

Pump curves, technical data Wilo-EMU FA 50.98D (740 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-

Wastewater transport
immersed)
IN IA P2 P1 A AW
A kW kg mm
FKT 50.1-8/54 270 1440 480 132.0 142.0 S1/S1 2484 2407 1523
FKT 50.1-8/62 335 1720 580 165.0 177.0 S1/S1 2590 2407 1523
FKT 56-8/53 (Ex) 375 2200 740 195.0 205.0 S1/S1 2450 2241 1431
FKT 56-8/58 (Ex) 405 2450 820 210.0 230.0 S1/S1 2630 2241 1431
FKT 56-8/64 (Ex) 445 2700 900 230.0 250.0 S1/S1 2840 2361 1551
FKT 56-8/70 (Ex) 490 2950 990 255.0 275.0 S1/S1 3120 2361 1551
FKT 56-8/78 (Ex) 550 3450 1150 285.0 305.0 S1/S1 3340 2441 1631
T 50.1-8/45 260 1170 390 132.0 142.0 S1/– 1980 2317 1433
T 50.1-8/54 325 1600 540 165.0 177.0 S1/– 2131 2407 1523
T 50.1-8/62 390 1740 580 195.0 210.0 S1/– 2237 2407 1523
T 56-8/53 (Ex) 435 2200 730 230.0 245.0 S1/– 2190 2196 1386
T 56-8/58 (Ex) 480 2450 820 255.0 270.0 S1/– 2370 2196 1386
T 56-8/64 (Ex) 520 2700 900 275.0 290.0 S1/– 2580 2316 1506
T 56-8/70 (Ex) 570 2960 980 305.0 320.0 S1/– 2860 2316 1506
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FKT 50.1… NBR - SiC/SiC, SiC/SiC -
FKT 56... NBR - SiC/SiC, SiC/SiC -
T 50.1… NBR - SiC/SiC, SiC/SiC -
T 56... NBR - SiC/SiC, SiC/SiC -

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FKT 50.1… ǽ ǽ • • – • ǽ •
FKT 56... ǽ • • • ǽ • ǽ •
T 50.1… ǽ ǽ • • • • ǽ •
T 56... ǽ ǽ • • • – ǽ ǽ
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 293
Wastewater transport
Submersible pumps DN 300 to DN 600

Dimensions Wilo-EMU FA 50.98D (740 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

2200 x
2000 *

*
* *
*
*
* *

*
*

*
*
AW

1
*
230

*
1000
573
1310

450
630

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

868
26

1600
1480

1530

1060 1050
730

1200 1806
1203

2
3

1750

1 = DN500 PN10 / ANSI B16.1, Class 125, Size 20; 2 = DN600 PN10 / ANSI B16.1, Class 125, Size 24; 3 = DN600 PN10; * = on request

294 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps DN 300 to DN 600

Pump curves, technical data Wilo-EMU FA 50.98D (950 rpm)

Pump curves Wilo-EMU FA 50.98D - 50 Hz - 950 rpm


Multi-channel impeller - Free ball passage: 100 mm

H/m

Wastewater transport
60
70%
75%
50 80%
85%

40
85%

30 80%
75%
Ø 700
Ø 680
20
Ø 660
Ø 640
Ø 620
10 Ø 600

0
0 1000 2000 3000 4000 5000 6000 Q/m³/h

0 200 400 600 800 1000 1200 1400 1600 1800 Q/l/s
P2/kW

600
Ø 700
Ø 680
400
Ø 660
Ø 640
Ø 620
Ø 600
200

0
0 1000 2000 3000 4000 5000 6000 Q/m³/h

0 200 400 600 800 1000 1200 1400 1600 1800 Q/l/s

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 50.98D 120 Multi-channel impeller 2350
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 295
Wastewater transport
Submersible pumps DN 300 to DN 600

Pump curves, technical data Wilo-EMU FA 50.98D (950 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-
immersed)
IN IA P2 P1 A AW
A kW kg mm
FKT 56-6/70 (Ex) 560 4000 1340 310.0 325.0 S1/S1 3120 2361 1551
FKT 56-6/78 (Ex) 640 4540 1520 340.0 370.0 S1/S1 3340 2441 1631
FKT 72-6/54 760 5300 1740 420.0 450.0 S1/S1 5220 2323 1707
FKT 72-6/60 820 5700 1890 450.0 480.0 S1/S1 5560 2383 1767
FKT 72-6/66 910 6400 2140 500.0 540.0 S1/S1 5850 2523 1907
FKT 72-6/73 980 7100 2350 540.0 580.0 S1/S1 6180 2523 1907
FKT 72-6/80 1100 7700 2550 610.0 650.0 S1/S1 6520 2593 1977
T 56-6/58 (Ex) 550 3100 1030 310.0 325.0 S1/– 2370 2196 1386
T 56-6/64 (Ex) 610 3600 1200 340.0 355.0 S1/– 2580 2316 1506
T 56-6/70 (Ex) 660 4050 1360 375.0 390.0 S1/– 2860 2316 1506
T 56-6/78 (Ex) 740 3880 1270 420.0 435.0 S1/– 3080 2416 1606
T 72-6/54 880 5300 1740 500.0 520.0 S1/– 4210 2615 1790
T 72-6/66 1080 6400 2150 610.0 640.0 S1/– 4595 2755 1930
T 72-6/73 1180 7120 2380 670.0 700.0 S1/– 4820 2755 1930
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FKT 56... NBR - SiC/SiC, SiC/SiC -
FKT 72... NBR - SiC/SiC, SiC/SiC -
T 56... NBR - SiC/SiC, SiC/SiC -
T 72... NBR - SiC/SiC, SiC/SiC -

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FKT 56... ǽ • • • ǽ • ǽ •
FKT 72... - - • • ǽ • • •
T 56... ǽ ǽ • • • – ǽ ǽ
T 72... - - • • • – • ǽ
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

296 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps DN 300 to DN 600

Dimensions Wilo-EMU FA 50.98D (950 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

2200 x

Wastewater transport
2000 *

*
* *
*
*
* *

*
*

*
*
AW

1
*
230

*
1000
573
1310

450
630

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

868
26

1600
1480

1530

1060 1050
730

1200 1806
1203

2
3

1750

1 = DN500 PN10 / ANSI B16.1, Class 125, Size 20; 2 = DN600 PN10 / ANSI B16.1, Class 125, Size 24; 3 = DN600 PN10; * = on request

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 297
Wastewater transport
Submersible pumps DN 300 to DN 600

Pump curves, technical data Wilo-EMU FA 60.83V (585 rpm)

Pump curves Wilo-EMU FA 60.83V - 50 Hz - 585 rpm


Multi-channel impeller - Free ball passage: 125 mm

H[m]
18
20%
40%
16 50%
60%
70%
14

80%
12

10
80%
8
Ø 605
6
Ø 545
Ø 485
4

0
0 1000 2000 3000 4000 5000 Q[m³/h]

0 200 400 600 800 1000 1200 1400 Q[l/s]

P2[kW]
Ø 605
120
Ø 545
Ø 485
80

40

0
0 1000 2000 3000 4000 5000 Q[m³/h]

0 200 400 600 800 1000 1200 1400 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 60.83V 125 Multi-channel impeller 2040
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

298 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps DN 300 to DN 600

Pump curves, technical data Wilo-EMU FA 60.83V (585 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-

Wastewater transport
immersed)
IN IA P2 P1 A AW
A kW kg mm
FKT 50.1-10/58 255 1220 410 120.0 130.0 S1/S1 2530 2406 1523
FKT 50.1-10/62 280 1300 440 132.0 143.0 S1/S1 2582 2406 1523
FKT 56-10/53 (Ex) 310 1800 600 160.0 174.0 S1/S1 2450 2241 1431
T 50.1-10/46 250 980 330 120.0 131.0 S1/– 1994 2317 1433
T 50.1-10/58 300 1240 420 145.0 157.0 S1/– 2176 2407 1523
T 50.1-10/62 330 1320 440 160.0 173.0 S1/– 2229 2407 1523
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FKT 50.1… NBR - SiC/SiC, SiC/SiC -
FKT 56... NBR - SiC/SiC, SiC/SiC -
T 50.1… NBR - SiC/SiC, SiC/SiC -

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FKT 50.1… ǽ ǽ • • – • ǽ •
FKT 56... ǽ • • • ǽ • ǽ •
T 50.1… ǽ ǽ • • • • ǽ •
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 299
Wastewater transport
Submersible pumps DN 300 to DN 600

Dimensions Wilo-EMU FA 60.83V (585 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

2500 x 2000
*
*
*
*
* *
* *

*
*
AW

*
1
550 375

* * *
1000

*
500
1575

700

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

26
944
1652
1700
1580
940

1500
1353

1360
2 1150
1982
3

1950

1 = DN600 PN10 / ANSI B16.1, Class 125, Size 24; 2 = DN700 PN10 / ANSI B16.1, Class 125, Size 30; 3 = DN700 PN10; * = on request

300 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps DN 300 to DN 600

Pump curves, technical data Wilo-EMU FA 60.83V (740 rpm)

Pump curves Wilo-EMU FA 60.83V - 50 Hz - 740 rpm


Multi-channel impeller - Free ball passage: 125 mm

H[m]

Wastewater transport
28

70%
24
74%
77%

79%
20
79%

77%
16 80%
74%
80% 70%

12

Ø 560 Ø 615
Ø 540
4
Ø 485

0
0 1000 2000 3000 4000 5000 6000 7000 8000 Q[m³/h]

0 400 800 1200 1600 2000 Q[l/s]

P2[kW]

300 Ø 615
Ø 560
200 Ø 540
Ø 485
100

0
0 1000 2000 3000 4000 5000 6000 7000 8000 Q[m³/h]

0 400 800 1200 1600 2000 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 60.83V 125 Multi-channel impeller 2040
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 301
Wastewater transport
Submersible pumps DN 300 to DN 600

Pump curves, technical data Wilo-EMU FA 60.83V (740 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting current Nominal Power Operating Motor Dimensions
current rent - direct - star-delta motor consump- mode (im- weight
power tion mersed/non-
immersed)
IN IA P2 P1 A AW
A kW kg mm
FKT 56-8/64 (Ex) 445 2700 900 230.0 250.0 S1/S1 2840 2361 1551
FKT 56-8/70 (Ex) 490 2950 990 255.0 275.0 S1/S1 3120 2361 1551
FKT 56-8/78 (Ex) 550 3450 1150 285.0 305.0 S1/S1 3340 2441 1631
FKT 72-8/53 610 3700 1230 320.0 345.0 S1/S1 5220 2323 1707
FKT 72-8/60 670 4150 1390 350.0 375.0 S1/S1 5560 2383 1767
FKT 72-8/66 760 4700 1560 400.0 430.0 S1/S1 5850 2523 1907
T 56-8/53 (Ex) 435 2200 730 230.0 245.0 S1/– 2190 2196 1386
T 56-8/58 (Ex) 480 2450 820 255.0 270.0 S1/– 2370 2196 1386
T 56-8/64 (Ex) 520 2700 900 275.0 290.0 S1/– 2580 2316 1506
T 56-8/70 (Ex) 570 2960 980 305.0 320.0 S1/– 2860 2316 1506
T 56-8/78 (Ex) 640 3450 1140 340.0 360.0 S1/– 3080 2416 1606
T 72-8/53 740 3700 1230 395.0 415.0 S1/– 4180 2615 1790
T 72-8/60 820 4150 1370 440.0 460.0 S1/– 4400 2588 1763
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
FKT 56... NBR - SiC/SiC, SiC/SiC -
FKT 72... NBR - SiC/SiC, SiC/SiC -
T 56... NBR - SiC/SiC, SiC/SiC -
T 72... NBR - SiC/SiC, SiC/SiC -

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
FKT 56... ǽ • • • ǽ • ǽ •
FKT 72... - - • • ǽ • • •
T 56... ǽ ǽ • • • – ǽ ǽ
T 72... - - • • • – • ǽ
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

302 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Wastewater transport
Submersible pumps DN 300 to DN 600

Dimensions Wilo-EMU FA 60.83V (740 rpm)

Dimension drawing Wilo-EMU FA - stationary wet well installation

2500 x 2000

Wastewater transport
*
*
*
*
* *
* *

*
*
AW

*
1
550 375

* * *
1000

*
500
1575

700

Dimension drawing Wilo-EMU FA - stationary dry well installation


A

26
944
1652
1700
1580
940

1
1500
1353

1360
2 1150
1982
3

1950

1 = DN600 PN10 / ANSI B16.1, Class 125, Size 24; 2 = DN700 PN10 / ANSI B16.1, Class 125, Size 30; 3 = DN700 PN10; * = on request

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 303
Dewatering

Series overview
Series Wilo-EMU KPR

Product photo
H/m

Wilo-EMU KPR...

Duty chart 4

0
0 500 1000 1500 2000 Q/l/s

• For pumping cooling water or rainwater


Application • Pumping of purified sewage
• For irrigation and pumping sludge.
Design Axial submersible pump with dry motor for use in pipe sumps
Qmax 9500 m3/h
Hmax 8.4 m
• Submersible
Special fea-
• Special materials and coatings against abrasion and corrosion
tures/product
• Longitudinally watertight cable inlet
advantages
• Angle of propeller blades adjustable by hand
Further
Series information from page 305
information

304 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Dewatering
Axial submersible water pumps

Series description Wilo-EMU KPR

Wilo-EMU KPR

|x{}

Dewatering
Design • Permanently lubricated roller bearings
Axial submersible pump with dry motor for use in pipe sumps • Max. immersion depth: 20 m

Type key Materials


Example: Wilo-EMU KPR 760-16° + T 49-10/53P Ex
• Housing components: EN-GJL
• Propeller: Stainless steel
Hydraulics: KPR 760-16° • Sealing on pump side: SiC/SiC
KPR Axial pump • Sealing on motor side: SiC/SiC
• Static seals: NBR
760 Propeller diameter • Shaft: Stainless steel 1.4021
16° Angular position of the propeller blades
Equipment/function
• Heavy-duty version in cast iron
Motor: T 49-10/53P Ex
T Motor version Description/design
49 Size Axial submersible pump as submersible monobloc unit for stationary
wet installation
10 Number of poles
53 x10 = package length [mm] Hydraulics
P Motor for axial pump The angle of the propeller/impeller blades can be adjusted by hand.
This makes it possible to adapt the unit to use in different conditions.
Ex Ex-rated
Motor
Application Dry motors (T motors) give off their heat directly to the surrounding
• For pumping cooling water or rainwater fluid via the housing components and can be used in immersed state
• Pumping of purified sewage for permanent operation.
• For irrigation and pumping sludge.
A sealing chamber protects the motor from fluid ingress. It can be ac-
Special features/product advantages cessed from the outside and can be monitored with an optional seal-
• Submersible ing chamber electrode.
• Special materials and coatings against abrasion and corrosion
• Longitudinally watertight cable inlet All filling fluids used are potentially biodegradable and environmen-
• Angle of propeller blades adjustable by hand tally safe.

The cable inlet of the T motors is longitudinally watertight. Cable


Technical data lengths can be individually configured.
• Mains connection: 3~400 V, 50 Hz
• Immersed operating mode: S1 Sealing
• Protection class: IP 68 Fluid-side and motor-side sealing is possible in the following ver-
• Max. fluid temperature: 3 - 40°C, higher temperatures on request sions depending on the motor type:
• Sealing: With two mechanical seals or one block seal cartridge, de- • Version G: Two independently operating mechanical seals
pending on the motor
• Version K: Block seal cartridge with two independently operating me-
• Free ball passage: 85 - 130 mm. chanical seals
• Short common pump/motor shaft

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 305
Dewatering
Axial submersible water pumps

Series description Wilo-EMU KPR

Options Accessories
• Special voltages • Switchgears, relays and plugs
• PTC thermistor sensor
• Internal or external sealing chamber control Commissioning
• Monitoring units for leakage and bearing temperature Operation with surfaced motor:
• Ceram coating C0, C1 Dry motors (T motors) can be surfaced only if there is an operating
• Ex-rated according to ATEX or FM mode for surfaced operation.

Scope of delivery Dry-running protection system:


• Axial submersible pump The hydraulics housing must always be immersed to prevent air from
• Cable length per customer request being drawn in. In the case of fluctuating fluid levels, the system
• Accessories per customer request should switch off automatically once the minimum water submersion
• Operating and maintenance manual is reached.

H/m
Wilo-EMU KPR...
8

7
KPR500
950min-1
6
KPR340 KPR760
1450min-1 585min-1
5

3
KPR500
740min-1
2
KPR340
950min-1
1

0
0 500 1000 1500 2000 2500 Q/l/s

306 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Dewatering
Axial submersible water pumps

Pump curves, technical data Wilo-EMU KPR 340 (950 rpm)

Pump curves Wilo-EMU KPR 340 - 50 Hz - 950 rpm


Axial impeller - Free ball passage: 85 mm

H[m]
3,6

3,2

2,8
59%

2,4
62%
67% 65%
2,0

1,6 62%

59%
1,2
14° 16°
8° 10° 12°

Dewatering
0,8

5° 6°

0,4

0
0 200 400 600 800 1000 1200 Q[m³/h]

0 50 100 150 200 250 300 350 Q[l/s]

P2[kW]

12

16°
14°
4
8° 10° 12°
4° 5° 6° 7°
0
0 200 400 600 800 1000 1200 Q[m³/h]

0 50 100 150 200 250 300 350 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
KPR 340 85 Axial impeller 160
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 307
Dewatering
Axial submersible water pumps

Pump curves, technical data Wilo-EMU KPR 340 (950 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting cur- Nominal Power Operating Motor Dimen-
current rent - direct rent - star- motor consump- mode (im- weight sions
delta power tion mersed/non-
immersed)
IN IA P2 P1 A
A kW kg mm
T 24-6/16P (Ex) 21 125 42 10.0 12.2 S1/– 140 893
T 24-6/22P (Ex) 33.5 200 66 16.5 19.9 S1/– 155 893
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
T 24...P NBR - - SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
T 24...P ǽ • • • • – ǽ •
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

308 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Dewatering
Axial submersible water pumps

Dimensions Wilo-EMU KPR 340 (950 rpm)

Dimension drawing Wilo-EMU KPR - stationary wet well installation

Dewatering
Ø711

Ø697
A

Ø630

Ø560

Ø 328
52x45°
10

70
507

188

Ø514

Ø550
270

Ø760

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 309
Dewatering
Axial submersible water pumps

Pump curves, technical data Wilo-EMU KPR 340 (1450 rpm)

Pump curves Wilo-EMU KPR 340 - 50 Hz - 1450 rpm


Axial impeller - Free ball passage: 85 mm

H[m]

60%
6

64%

5
70% 69%

4 66%

64%

3
60%

16°
2 14°
10° 12°





1

0
0 200 400 600 800 1000 1200 1400 1600 1800 Q[m³/h]

0 100 200 300 400 500 Q[l/s]

P2[kW]

30

20
16°
14°
10 12°
10°
4° 5° 6° 7° 8°
0
0 200 400 600 800 1000 1200 1400 1600 1800 Q[m³/h]

0 100 200 300 400 500 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
KPR 340 85 Axial impeller 160
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A

310 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Dewatering
Axial submersible water pumps

Pump curves, technical data Wilo-EMU KPR 340 (1450 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting cur- Nominal Power Operating Motor Dimen-
current rent - direct rent - star- motor consump- mode (im- weight sions
delta power tion mersed/non-
immersed)
IN IA P2 P1 A
A kW kg mm
T 24-4/21P (Ex) 35.5 230 76 17.5 20.5 S1/– 155 893
T 24-4/29P (Ex) 49.5 320 106 25.0 28.5 S1/– 190 958
T 24-4/36P (Ex) 68 480 159 34.0 39.0 S1/– 217 1028
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K

Dewatering
T 24...P NBR - - SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
T 24...P ǽ • • • • – ǽ •
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 311
Dewatering
Axial submersible water pumps

Dimensions Wilo-EMU KPR 340 (1450 rpm)

Dimension drawing Wilo-EMU KPR - stationary wet well installation

Ø711

Ø697
A

Ø630

Ø560

Ø 328
52x45°
10

70
507

188

Ø514

Ø550
270

Ø760

312 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Dewatering
Axial submersible water pumps

Pump curves, technical data Wilo-EMU KPR 500 (740 rpm)

Pump curves Wilo-EMU KPR 500 - 50 Hz - 740 rpm


Axial impeller - Free ball passage: 110 mm

H[m]

62% 68%
4,5 72%

4,0

76%
3,5
74%

3,0
72%

2,5 68%

62%
2,0

1,5

Dewatering
1,0
12° 14° 16°
10°
0,5
4° 6° 8°

0
0 500 1000 1500 2000 2500 3000 3500 Q[m³/h]

0 200 400 600 800 1000 Q[l/s]

P2[kW]

30

20
14° 16°
10° 12°
10
6° 8°

0
0 500 1000 1500 2000 2500 3000 3500 Q[m³/h]

0 200 400 600 800 1000 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
KPR 500 110 Axial impeller 385
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 313
Dewatering
Axial submersible water pumps

Pump curves, technical data Wilo-EMU KPR 500 (740 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting cur- Nominal Power Operating Motor Dimen-
current rent - direct rent - star- motor consump- mode (im- weight sions
delta power tion mersed/non-
immersed)
IN IA P2 P1 A
A kW kg mm
T 30-8/29P (Ex) 42.5 220 73 20.0 23.0 S1/– 330 1022
T 30-8/35P (Ex) 51 270 90 24.0 27.5 S1/– 364 1082
T 30-8/45P (Ex) 67 360 119 31.5 36.0 S1/– 415 1172
T 30-8/57P (Ex) 85 450 149 40.0 45.5 S1/– 487 1281
T 34-8/29P (Ex) 66 360 119 32.5 37.5 S1/– 391 1076
T 34-8/32P (Ex) 73 400 132 35.0 40.0 S1/– 420 1076
T 34-8/41P (Ex) 93 510 169 45.0 52.0 S1/– 478 1156
T 34-8/50P (Ex) 111 630 210 55.0 62.0 S1/– 544 1226
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
T 30...P NBR - - SiC/SiC, SiC/SiC
T 34...P NBR - - SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
T 30...P ǽ ǽ • • • – ǽ •
T 34...P ǽ ǽ • ǽ ǽ – ǽ •
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

314 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Dewatering
Axial submersible water pumps

Dimensions Wilo-EMU KPR 500 (740 rpm)

Dimension drawing Wilo-EMU KPR - stationary wet well installation

Ø813

Ø797

Dewatering
Ø775
A

Ø680

Ø456
42x45°
41

70
707

250

660

Ø680
320

Ø950

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 315
Dewatering
Axial submersible water pumps

Pump curves, technical data Wilo-EMU KPR 500 (950 rpm)

Pump curves Wilo-EMU KPR 500 - 50 Hz - 950 rpm


Axial impeller - Free ball passage: 110 mm

H[m]
9

8
66%
72%
76%
7

6
80%
79%
5
76%

4 72%

66%
3
58%

16°
12° 14°
1
4° 6° 8° 10°

0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 Q[m³/h]

0 200 400 600 800 1000 1200 Q[l/s]

P2[kW]

60

40 16°
14°
10° 12°
20
6° 8°

0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 Q[m³/h]

0 200 400 600 800 1000 1200 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
KPR 500 110 Axial impeller 385
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A

316 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Dewatering
Axial submersible water pumps

Pump curves, technical data Wilo-EMU KPR 500 (950 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting cur- Nominal Power Operating Motor Dimen-
current rent - direct rent - star- motor consump- mode (im- weight sions
delta power tion mersed/non-
immersed)
IN IA P2 P1 A
A kW kg mm
T 30-6/28P (Ex) 60 330 109 30.0 34.0 S1/– 324 1022
T 30-6/35P (Ex) 75 410 136 37.5 42.5 S1/– 364 1082
T 30-6/41P (Ex) 88 480 159 44.0 49.5 S1/– 395 1172
T 30-6/48P (Ex) 102 580 192 51.5 58.0 S1/– 506 1281
T 34-6/29P (Ex) 85 490 162 45.0 49.0 S1/– 391 1076
T 34-6/32P (Ex) 94 540 179 50.0 55.0 S1/– 420 1076
T 34-6/41P (Ex) 124 670 225 65.0 70.0 S1/– 478 1156
T 34-6/50P (Ex) 136 790 265 70.0 78.0 S1/– 544 1226
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.

Dewatering
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
T 30...P NBR - - SiC/SiC, SiC/SiC
T 34...P NBR - - SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
T 30...P ǽ ǽ • • • – ǽ •
T 34...P ǽ ǽ • ǽ ǽ – ǽ •
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 317
Dewatering
Axial submersible water pumps

Dimensions Wilo-EMU KPR 500 (950 rpm)

Dimension drawing Wilo-EMU KPR - stationary wet well installation

Ø813

Ø797

Ø775
A

Ø680

Ø456
42x45°
41

70
707

250

660

Ø680
320

Ø950

318 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Dewatering
Axial submersible water pumps

Pump curves, technical data Wilo-EMU KPR 760 (585 rpm)

Pump curves Wilo-EMU KPR 760 - 50 Hz - 585 rpm


Axial impeller - Free ball passage: 130 mm

H[m]

8
61% 64%
67% 70%
7

75%
6

73%
5
70%

4 67%

64%
61%
3
56%

Dewatering
18° 20°
1 14° 16°
10° 12°
6° 8°

0
0 2000 4000 6000 8000 10000 Q[m³/h]

0 400 800 1200 1600 2000 2400 2800 Q[l/s]

P2[kW]

150

100
18° 20°
16°
50 14°
6° 8° 10° 12°
0
0 2000 4000 6000 8000 10000 Q[m³/h]

0 400 800 1200 1600 2000 2400 2800 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
KPR 760 130 Axial impeller 1050
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 319
Dewatering
Axial submersible water pumps

Pump curves, technical data Wilo-EMU KPR 760 (585 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting cur- Nominal Power Operating Motor Dimen-
current rent - direct rent - star- motor consump- mode (im- weight sions
delta power tion mersed/non-
immersed)
IN IA P2 P1 A
A kW kg mm
T 49-10/36P (Ex) 188 830 275 95.0 103.0 S1/– 1485 1906
T 49-10/43P (Ex) 240 1020 340 120.0 130.0 S1/– 1600 1906
T 49-10/53P (Ex) 285 1260 420 145.0 156.0 S1/– 1765 2056
T 49-10/58P (Ex) 315 1450 480 160.0 171.0 S1/– 1850 2056
T 56-10/53P 380 1800 600 200.0 215.0 S1/– 2160 2051
T 56-10/58P 405 1950 650 215.0 230.0 S1/– 2260 2051
T 56-10/64P 445 2150 710 235.0 250.0 S1/– 2375 2171
T 56-10/70P 480 2400 800 255.0 270.0 S1/– 2490 2171
T 56-10/78P 540 2700 900 285.0 305.0 S1/– 2235 2251
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
T 49...P NBR - SiC/SiC, SiC/SiC -
T 56...P NBR - SiC/SiC, SiC/SiC -

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
T 49...P - ǽ • • • – ǽ •
T 56...P - - • • • – ǽ ǽ
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

320 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Dewatering
Axial submersible water pumps

Dimensions Wilo-EMU KPR 760 (585 rpm)

Dimension drawing Wilo-EMU KPR - stationary wet well installation

Ø1100

Dewatering
A

Ø1058

Ø990

Ø670

30°
80
1057

Ø975
10
365

Ø990
520

Ø1200

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 321
Industrial processes

Series overview
Series Wilo-EMU FA...RF

Product photo
H/m

Wilo-EMU FA...RF

40
30
20

Duty chart 10

1
1 2 3 4 5 10 20 Q/l/s

Application • In water treatment applications or industrial applications


Design Submersible sewage pump made of cast stainless steel
Qmax 70 m3/h
Hmax 30 m
• Operation in stationary and portable wet well installation
• Submersible
Special fea-
• Version made completely of cast stainless steel 1.4581
tures/product
• Easy installation due to suspension unit or pump base
advantages
• Longitudinally watertight cable lead-in
• Adapt the duty point by trimming the impeller (for FA 08…RF)
Further
Series information from page 323
information

322 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Industrial processes
Submersible pumps made of cast stainless steel

Series description Wilo-EMU FA...RF

Wilo-EMU FA...RF

yZ
Design Technical data
Submersible sewage pump made of cast stainless steel • Mains connection: 3~400 V, 50 Hz
• Immersed operating mode: S1
Type key • Protection class: IP 68
• Max. fluid temperature: 3 - 40 °C, higher temperatures on request
Example: Wilo-EMU FA 05.23RFW + T 12-2/11G Ex • Sealing: With two mechanical seals or one block seal cartridge, de-
Hydraulics: FA 05.23RFW pending on the motor
• Free ball passage: 35 - 45 mm.
FA Submersible sewage pump
• Permanently lubricated roller bearings
05 x10 = nominal diameter of the pressure port, e.g. • Max. immersion depth: 20 m
DN50

Industrial processes
23 Performance indicator Materials
RF Special cast stainless steel material • Housing parts: Cast stainless steel 1.4581
• Impeller: Cast stainless steel 1.4581
W Type of impeller • Sealing on pump side: SiC/SiC
• Sealing on motor side: Viton or SiC/SiC
• Static seals: Viton
Motor: T 12-2/11G Ex
• Shaft: Stainless steel 1.4462
T Motor version
12 Size Equipment/function
2 Number of poles • Heavy-duty version made of cast stainless steel (1.4581)
• Simple installation through the use of suspension unit or pump base
11 x10 = package length [mm]
G Sealing version Description/design
Ex Ex-rated Submersible sewage pump as submersible monobloc unit for station-
ary and portable wet well installation.

Application Hydraulics
• In water treatment applications or industrial applications The outlet on the pressure side is designed as horizontal flange con-
nection. The maximum possible dry matter content is 8%, depending
Special features/product advantages on the hydraulics and impeller type.
• Operation in stationary and portable wet well installation
• Submersible The following impeller shapes are used:
• Version made completely of cast stainless steel 1.4581 • Vortex impeller (W)
• Easy installation due to suspension unit or pump base • Single-channel impeller (E)
• Longitudinally watertight cable lead-in
• Adapt the duty point by trimming the impeller (for FA 08…RF) Depending on type, single-channel hydraulic systems can be
equipped with a counter ring and/or a stationary wear ring made of
hardened material. These contribute long-term to ensuring the uni-
form efficiency of the unit.

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 323
Industrial processes
Submersible pumps made of cast stainless steel

Series description Wilo-EMU FA...RF

Motor Scope of delivery


Dry motors (T motors) give off their heat directly to the surrounding • Submersible sewage pump made of cast stainless steel
fluid via the housing components and can be used in immersed state • Cable length per customer request
for permanent operation. • Accessories per customer request
• Operating and maintenance manual
A sealing chamber protects the motor from fluid ingress. It can be ac-
cessed from the outside and can be monitored with an optional seal- Accessories
ing chamber electrode. • Suspension unit or pump base
• Various pressure outlets and Storz couplings
All filling fluids used are potentially biodegradable and environmen- • Chains
tally safe. • Fixation sets with anchor bolts
• Switchgears, relays and plugs
The cable inlet on the T motors is longitudinally watertight, cable
lengths can be individually configured.
Commissioning
Sealing Operation with non-immersed motor:
Dry motors (T motors) can be surfaced only if there is an operating
Fluid-side and motor-side sealing is possible in the following ver-
mode for surfaced operation.
sions depending on the motor type:
• Version G: Two independently operating mechanical seals
Dry-running protection system:
• Version K: Block seal cartridge with two independently operating me-
The hydraulics housing must always be immersed to prevent air from
chanical seals
being drawn in. In the case of fluctuating fluid levels, the system
should switch off automatically once the minimum water submersion
Options is reached.
• Special voltages
• PTC thermistor sensor
• Internal or external sealing chamber control
• Monitoring units for leakage and bearing temperature
• Ex-rated to ATEX or FM

H/m
Wilo-EMU FA...RF...

50
40

30

20

FA05.32RFE (2900 1/min)


FA08.34RFE
10

FA05.23RFW
5
4
3 FA05.32RFE (1450 1/min)

1
1 2 3 4 5 10 20 Q/l/s

324 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Industrial processes
Submersible pumps made of cast stainless steel

Pump curves, technical data Wilo-EMU FA 05.23RFW (2900 rpm)

Pump curves Wilo-EMU FA 05.23RFW - 50 Hz - 2900 rpm


Vortex impeller - Free ball passage: 35 mm

H[m]

16

20%
14 30%
40%
45%
12

10

40%
6

30%
4

20%
2 Ø 133
Ø 116 Ø 127
Ø 108
Ø 100
0
0 10 20 30 40 50 Q[m³/h]

0 2 4 6 8 10 12 14 Q[l/s]

P2[kW] Ø 133

Ø 127

Industrial processes
1,2
Ø 116
0,8 Ø 108
Ø 100
0,4

0
0 10 20 30 40 50 Q[m³/h]

0 2 4 6 8 10 12 14 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 05.23RFW 35 Vortex impeller 11
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 325
Industrial processes
Submersible pumps made of cast stainless steel

Pump curves, technical data Wilo-EMU FA 05.23RFW (2900 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting cur- Nominal Power Operating Motor Dimen-
current rent - direct rent - star- motor consump- mode (im- weight sions
delta power tion mersed/non-
immersed)
IN IA P2 P1 A
A kW kg mm
T 12-2/11RF (Ex) 4.45 26 8.8 2.0 2.6 S1/S2-15 min 29 379
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
T 12... FPM - SiC/SiC, SiC/SiC -

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
T 12... ǽ ǽ • • ǽ – - -
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

326 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Industrial processes
Submersible pumps made of cast stainless steel

Dimensions Wilo-EMU FA 05.23RFW (2900 rpm)

Dimension drawing Wilo-EMU FA...RF - stationary wet well installation

625
90, 95
320

DN 32 33
109 90
55
G4

120
80

18
43 3
AW

80
61 42

260
162

120

Dimension drawing Wilo-EMU FA...RF - portable installation

511
150
2

50

Industrial processes
128
271

Ø233

389
1

407
80
281

150
265
273
163

121
64

Ø250

1 = DN50 PN10 / ANSI B16.1, Class 125, Size 2; 2 = DN50 PN10; 3 = G2

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 327
Industrial processes
Submersible pumps made of cast stainless steel

Pump curves, technical data Wilo-EMU FA 05.32RFE (1450 rpm)

Pump curves Wilo-EMU FA 05.32RFE - 50 Hz - 1450 rpm


Single-channel impeller - Free ball passage: 45 mm

H[m]

Ø 144
4

Ø 125
2

0
0 5 10 15 20 25 30 35 40 Q[m³/h]

0 2 4 6 8 10 Q[l/s]

P2[kW]

0,6

Ø 144
0,4

0,2 Ø 125

0
0 5 10 15 20 25 30 35 40 Q[m³/h]

0 2 4 6 8 10 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 05.32RFE 45 Single-channel impeller 13
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

328 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Industrial processes
Submersible pumps made of cast stainless steel

Pump curves, technical data Wilo-EMU FA 05.32RFE (1450 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting cur- Nominal Power Operating Motor Dimen-
current rent - direct rent - star- motor consump- mode (im- weight sions
delta power tion mersed/non-
immersed)
IN IA P2 P1 A
A kW kg mm
T 12-4/11RF (Ex) 3.25 16 6 1.3 1.7 S1/S2-15 min 29 379
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
T 12... FPM - SiC/SiC, SiC/SiC -

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
T 12... ǽ ǽ • • ǽ – - -
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.

Industrial processes
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 329
Industrial processes
Submersible pumps made of cast stainless steel

Dimensions Wilo-EMU FA 05.32RFE (1450 rpm)

Dimension drawing Wilo-EMU FA...RF - stationary wet well installation

625
90, 95
320

DN 32 33
109 90
55
G4

120
80

18
43
AW

3
80
61 42

260
162

120

Dimension drawing Wilo-EMU FA...RF - portable installation

511
150
2

50
128
Ø233
271

389
1

407
80 150
281

265
273
163

121
64

Ø250

1 = DN50 PN10 / ANSI B16.1, Class 125, Size 2; 2 = DN50 PN10; 3 = G2

330 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Industrial processes
Submersible pumps made of cast stainless steel

Pump curves, technical data Wilo-EMU FA 05.32RFE (2900 rpm)

Pump curves Wilo-EMU FA 05.32RFE - 50 Hz - 2900 rpm


Single-channel impeller - Free ball passage: 45 mm

H[m]

24

20%
20 30%
40%
50%
58%
16 62%

12

Ø 125
8
50%

Ø 112
4
Ø 100

0
0 10 20 30 40 50 Q[m³/h]

0 2 4 6 8 10 12 14 Q[l/s]

P2[kW]

Ø 125

Industrial processes
1,5
Ø 112
1,0
Ø 100
0,5

0
0 10 20 30 40 50 Q[m³/h]

0 2 4 6 8 10 12 14 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 05.32RFE 45 Single-channel impeller 13
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 331
Industrial processes
Submersible pumps made of cast stainless steel

Pump curves, technical data Wilo-EMU FA 05.32RFE (2900 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting cur- Nominal Power Operating Motor Dimen-
current rent - direct rent - star- motor consump- mode (im- weight sions
delta power tion mersed/non-
immersed)
IN IA P2 P1 A
A kW kg mm
T 12-2/11RF (Ex) 4.45 26 8.8 2.0 2.6 S1/S2-15 min 29 379
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
T 12... FPM - SiC/SiC, SiC/SiC -

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
T 12... ǽ ǽ • • ǽ – - -
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

332 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Industrial processes
Submersible pumps made of cast stainless steel

Dimensions Wilo-EMU FA 05.32RFE (2900 rpm)

Dimension drawing Wilo-EMU FA...RF - stationary wet well installation

625
90, 95
320

DN 32 33
109 90
55
G4

120
80

18
43
AW

3
80
61 42

260
162

120

Dimension drawing Wilo-EMU FA...RF - portable installation

511
150
2

50

Industrial processes
128
Ø233
271

389
1

407
80 150
281

265
273
163

121
64

Ø250

1 = DN50 PN10 / ANSI B16.1, Class 125, Size 2; 2 = DN50 PN10; 3 = G2

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 333
Industrial processes
Submersible pumps made of cast stainless steel

Pump curves, technical data Wilo-EMU FA 08.34RFE (2900 rpm)

Pump curves Wilo-EMU FA 08.34RFE - 50 Hz - 2900 rpm


Single-channel impeller - Free ball passage: 45 mm

H[m]

32

20%
28
40%
50%
24 58%
64%
68%
20
Ø 150
16
Ø 145

12
Ø 140
Ø 135
8
Ø 130
40%
4 Ø 125

20% Ø 115 Ø 120


Ø 110
0 Ø 105
0 20 40 60 80 100 Q[m³/h]

0 4 8 12 16 20 24 28 Q[l/s]

P2[kW]

4 Ø 150
Ø 145
Ø 140
3 Ø 135
Ø 130
Ø 125
2 Ø 120
Ø 115
Ø 110
1 Ø 105

0
0 20 40 60 80 100 Q[m³/h]

0 4 8 12 16 20 24 28 Q[l/s]

Hydraulic data

Wilo-EMU... Free ball passage Type of impeller Weight of hydraulic unit


mm kg
FA 08.34RFE 45 Single-channel impeller 18
Pump curves apply to 3~400 V, 50 Hz at standard speed and a density of 1 kg/dm3. Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of
efficiency correspond to the hydraulic efficiency.

334 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Industrial processes
Submersible pumps made of cast stainless steel

Pump curves, technical data Wilo-EMU FA 08.34RFE (2900 rpm)

Motor data for 3~400 V, 50 Hz

Nominal Starting cur- Starting cur- Nominal Power Operating Motor Dimen-
current rent - direct rent - star- motor consump- mode (im- weight sions
delta power tion mersed/non-
immersed)
IN IA P2 P1 A
A kW kg mm
T 13-2/12RF Ex 5.3 37 13 2.2 3.0 S1/S2-15 min 37 394
T 13-2/12RF Ex 7.1 37 13 3.5 4.4 S1/S2-15 min 37 394
T 13-2/16RF Ex 9.7 64 22 5.0 5.9 S1/S2-15 min 40 449
P1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm3.
Voltage tolerance +/- 10 % (specifications according to DIN EN 60034)

Materials: Seals

Static seal Sealing


Version H Version G Version K
T 13... FPM FPM, SiC/SiC - SiC/SiC, SiC/SiC

Equipment/function

Explosion Motor tem- Motor leak- Sealing cham- Leakage Bearing tem- Terminal
protection ac- perature age detection ber leakage chamber perature chamber
cording to monitoring detection leakage de- monitoring leakage de-
tection tection
ATEX FM
T 13... ǽ ǽ • • ǽ – - -

Industrial processes
Evaluation relays for PTC or PT100 sensors must be fitted as required for the connection of monitoring devices. These relays must be ordered separately as accesso-
ries. Note: the specifications may vary in the case of motors with ex-protection.
Customised configurations are available on request.
• = available; - = not available; ǽ = optional

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 335
Industrial processes
Submersible pumps made of cast stainless steel

Dimensions Wilo-EMU FA 08.34RFE (2900 rpm)

Dimension drawing Wilo-EMU FA...RF - stationary wet well installation

625
324

90/98

DN 32
120
90 69
AW

166
59

110

170
15
50
40

50
1
77 39

300
249

210

Dimension drawing Wilo-EMU FA...RF - portable installation

165
2

555
75
125
230

1
3

437
366

453
150
411

100
265
388
240

201
124

Ø 344

1 = DN80 PN10 / ANSI B16.1, Class 125, Size 3; 2 = DN80 PN10; 3 = DN65 PN10 / ANSI B16.1, Class 125, Size 2,5

336 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Accessories

Mechanical accessories

Mechanical accessories – set of chains

Type Description Art no.


3m 6063139
5m 6063140
As chain sling with 2 shackles in galvanised steel. Bearing capacity: 400 kg
6m 6063141
10 m 6063142
3m 6063147
5m 6063148
As chain sling with 2 shackles in galvanised steel. Bearing capacity: 800 kg
6m 6063149
10 m 6063150
As chain sling with 2 shackles in galvanised steel. Bearing capacity: 2000 kg 10 m 6063152
As chain sling with 2 shackles in galvanised steel. Bearing capacity: 5000 kg 10 m 6063154
As chain sling with 2 shackles in galvanised steel. Bearing capacity: 7000 kg 10 m 6063156
Chain set PCS-CE As chain sling with 2 shackles in galvanised steel. Bearing capacity: 9000 kg 10 m 6063518
3m 6063135
5m 6063136
As chain sling with 2 shackles in 1.4401 stainless steel. Bearing capacity: 400 kg
6m 6063137
10 m 6063138
3m 6063143
5m 6063144
As chain sling with 2 shackles in 1.4401 stainless steel. Bearing capacity: 800 kg
6m 6063145
10 m 6063146
As chain sling with 2 shackles in 1.4401 stainless steel. Bearing capacity: 2000 kg 10 m 6063151
As chain sling with 2 shackles in 1.4401 stainless steel. Bearing capacity: 5000 kg 10 m 6063153
As chain sling with 2 shackles in 1.4401 stainless steel. Bearing capacity: 7000 kg 10 m 6063155
Accessories without item number are manufactured according to customer specification. More information on request.

Mechanical accessories – suspension units

Type Description Art no.


Made of EN-GJL-250, painted, with free passage in DN 50, coupling connection and
Suspension unit
foot without 90° pipe elbow, including profile joint, installation and floor fixation ac- FA 05.11 6036886
G2/1R
cessories and single-pipe guide pipe bracket (42.4x2 mm) without guide pipe.
For 2-pipe guide of EN-GJL-250, powder-coated, with free passage in DN 50, cou-
Suspension unit pling foot with 90° pipe elbow, including coupling connection, guide pipe bracket of
DN 50 6070146
DN50/2RK stainless steel for sump fixation, profile joint and mounting accessories; two guide
pipes (26.9 x 2 mm) are to be provided by the customer! Accessories
For 2-pipe guide of EN-GJL-250, powder-coated, with free passage in DN 65, cou-
Suspension unit pling foot with 90° pipe elbow, including coupling connection, guide pipe bracket of
DN 65 6070150
DN65/2RK stainless steel for sump fixation, profile joint and mounting accessories; two guide
pipes (26.9 x 2 mm) are to be provided by the customer!
Made of EN-GJL-250, painted, with free passage in DN 80, foot elbow including
Suspension unit
pump holder, profile joint, installation and floor fixation accessories and double-pipe DN 80 6036888
DN 80/2RK
guide pipe bracket (42.4x2 mm) without guide pipes.
Made of EN-GJL-250, painted, with free passage in DN 100, foot elbow including
Suspension unit EHV
pump holder, profile joint, installation and floor fixation accessories and double-pipe FA 10... 6036889
DN100/2RK
guide pipe bracket (42.4x2 mm) without guide pipes.
Made of EN-GJL-250, painted, with free passage in DN 150, foot elbow including
Suspension unit EHV
pump holder, profile joint, installation and floor fixation accessories and double-pipe FA 15... 6036890
DN150L/2RK
guide pipe bracket (42.4x2 mm) without guide pipes.

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 337
Accessories

Mechanical accessories

Mechanical accessories – suspension units

Type Description Art no.


Made of EN-GJL-250, painted, with free passage in DN 150, foot elbow including
Suspension unit EHV
pump holder, profile joint, installation and floor fixation accessories and double-pipe – –
DN150S/2RK
guide pipe bracket (60.3x3.6 mm) without guide pipes.
Made of EN-GJL-250, painted, with free passage in DN 200, foot without 90° pipe el-
Suspension unit EHV
bow, incl. pump holder, profile joint, installation and floor fixation accessories and – –
DN200/2R
single-pipe guide pipe bracket (42.4x2 mm), without guide pipes.
Made of EN-GJL-250, painted, with free passage in DN 250, foot elbow including
Suspension unit EHV
pump holder, profile joint, installation and floor fixation accessories and single-pipe – –
DN250/2R
guide pipe bracket (60.3x3.6 mm) without guide pipe.
Made of EN-GJL-250, painted, with free passage in DN 300, foot elbow including
Suspension unit EHV
pump holder, profile joint, installation and floor fixation accessories and double-pipe – –
DN300/2RK
guide pipe bracket (88.9x4.05 mm) without guide pipes.
Made of EN-GJL-250, painted, with free passage in DN 350, foot elbow including
Suspension unit EHV
pump holder, profile joint, installation and floor fixation accessories and double-pipe – –
DN350/2RK
guide pipe bracket (60.3x3.6 mm) without guide pipes.
Made of EN-GJL-250, painted, with free passage in DN 400, foot elbow including
Suspension unit EHV
pump holder, profile joint, installation and floor fixation accessories and double-pipe – –
DN400/2RK
guide pipe bracket (60.3x3.6 mm) without guide pipes.
Made of EN-GJL-250, painted, with free passage in DN 500, foot elbow including
Suspension unit EHV
pump holder, profile joint, installation and floor fixation accessories and double-pipe – –
DN500/2RK
guide pipe bracket (88.9x4.05 mm) without guide pipes.
Made of EN-GJL-250, painted, with free passage in DN 600, foot elbow including
Suspension unit EHV
pump holder, profile joint, installation and floor fixation accessories and double-pipe – –
DN600/2RK
guide pipe bracket (88.9x4.05 mm) without guide pipes.
Base frame for sus- as an optional base carrier for suspension units from DN 300. When the base is cast,
– –
pension units the base frame is incorporated directly into the base.
for 2-pipe guide, of stainless steel, for pipe attachment on a cast-iron pipe, including
DN 50 6066851
mounting accessories
Guide pipe bracket
for 2-pipe guide, of stainless steel, for pipe attachment on a steel pipe, including
DN 50 6061084
mounting accessories
for 2-pipe guide, of stainless steel, for pipe attachment on a cast-iron pipe, including
DN 50 6066852
Bracket for guide mounting accessories
pipe extension for 2-pipe guide, of stainless steel, for pipe attachment on a steel pipe, including
DN 50 6066846
mounting accessories
for 2-pipe guide, of stainless steel, for pipe attachment on a cast-iron pipe, including
DN 65 6066847
mounting accessories
Guide pipe bracket
for 2-pipe guide, of stainless steel, for pipe attachment on a steel pipe, including
DN 65 6066848
mounting accessories
for 2-pipe guide, of stainless steel, for pipe attachment on a cast-iron pipe, including
DN 65 6066849
Bracket for guide mounting accessories
pipe extension for 2-pipe guide, of stainless steel, for pipe attachment on a steel pipe, including
DN 65 6066850
mounting accessories
Accessories without item number are manufactured according to customer specification. More information on request.

Mechanical accessories – coatings

Type Description Art no.


Ceram coating C0 External coating for corrosion protection on motors, hydraulics, impellers and accessories –
Ceram coating C1 Internal coating for corrosion protection and light abrasion protection for hydraulics and impellers. –
Ceram coating C2 Internal coating for corrosion protection and moderate abrasion protection for hydraulics and impellers. –
Ceram coating C3 Internal coating for corrosion protection and heavy abrasion protection for hydraulics and impellers. –
Accessories without item number are manufactured according to customer specification. More information on request.

338 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Accessories

Electrical accessories

Electrical accessories – switchgears

Type Description Art no.


EC-Drain PD 1 (1~230 V/50 Hz) Single-pump switchgear for controlling 1 submersible motor pump with dynamic pressure 2533842
EC-Drain PD 1 (3~400 V/50 Hz) system or 2 float switches of type WA 65, WA 95 or MS 1. 2533843
Microprocessor-controlled switchgear for level-dependent control of 1 submersible pump
in direct-on-line starting by means of float switches. Motor protection by means of inte-
MS-L-1x4kW-DOL 2539741
grated motor current and winding temperature monitoring. Not approved for controlling
pumps in potentially explosive areas!
Microprocessor-controlled switchgear for level-dependent control of 2 submersible
pumps in direct-on-line starting by means of float switches. Motor protection by means of
MS-L-2x4kW-DOL 2539745
integrated motor current and winding temperature monitoring. Not approved for control-
ling pumps in potentially explosive areas!
Single-pump switchgear for control of 1 submersible pump with dynamic pressure or bub-
DrainControl PL 1 (0.3-12 A) bling-through system, float switch or level sensor. Factory setting: level sensor 0-1 mWS 2522619
(4-20 mA). Level sensors from 0-1 mWS to 0-5 mWS can also be used.
Double-pump switchgear for control of 2 submersible pumps with dynamic pressure or
DrainControl PL 2 (0.3-12 A) bubbling-through system, float switch or level sensor. Factory setting: level sensor 2519069
0-2.5 mWS (4-20 mA). Level sensors from 0-1 mWS to 0-5 mWS can also be used.
SC-L-1x6A-M-DOL-WM 2538900
SC-L-1x9A-M-DOL-WM 2538904
SC-L-1x12A-M-DOL-WM 2538908
SC-L-1x2A-T4-DOL-WM 2538912
SC-L-1x4A-T4-DOL-WM 2538916
SC-L-1x6A-T4-DOL-WM 2538920
SC-L-1x9A-T4-DOL-WM 2538924
SC-L-1x12A-T4-DOL-WM 2538928
SC-L-1x16A-T4-DOL-WM Microprocessor-controlled switchgear in a steel enclosure (IP 54) with LC display and main 2538932
SC-L-1x20A-T4-DOL-WM switch for level-dependent control of 1 pump outside potentially explosive areas with level 2538936
SC-L-1x25A-T4-DOL-WM sensors or float switches 2538940
SC-L-1x32A-T4-DOL-WM 2538944
SC-L-1x12A-T4-SD-WM 2538948
SC-L-1x18A-T4-SD-WM 2538952
SC-L-1x24A-T4-SD-WM 2538956
SC-L-1x32A-T4-SD-WM 2538960
SC-L-1x42A-T4-SD-WM 2538964
SC-L-1x55A-T4-SD-WM 2538968
SC-L-1x72A-T4-SD-WM 2538972

Accessories

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 339
Accessories

Electrical accessories

Electrical accessories – switchgears

Type Description Art no.


SC-L-2x6A-M-DOL-WM 2538901
SC-L-2x9A-M-DOL-WM 2538905
SC-L-2x12A-M-DOL-WM 2538909
SC-L-2x2A-T4-DOL-WM 2538913
SC-L-2x4A-T4-DOL-WM 2538917
SC-L-2x6A-T4-DOL-WM 2538921
SC-L-2x9A-T4-DOL-WM 2538925
SC-L-2x12A-T4-DOL-WM 2538929
SC-L-2x16A-T4-DOL-WM Microprocessor-controlled switchgear in a steel enclosure (IP 54) with LC display and main 2538933
SC-L-2x20A-T4-DOL-WM switch for level-dependent control of 2 pumps outside potentially explosive areas with 2538937
SC-L-2x25A-T4-DOL-WM level sensors or float switches 2538941
SC-L-2x32A-T4-DOL-WM 2538945
SC-L-2x12A-T4-SD-WM 2538949
SC-L-2x18A-T4-SD-WM 2538953
SC-L-2x24A-T4-SD-WM 2538957
SC-L-2x32A-T4-SD-WM 2538961
SC-L-2x42A-T4-SD-WM 2538965
SC-L-2x55A-T4-SD-WM 2538969
SC-L-2x72A-T4-SD-WM 2538973
SC-L-1x6A-M-DOL-WM-Ex 2538976
SC-L-1x9A-M-DOL-WM-Ex 2538980
SC-L-1x12A-M-DOL-WM-Ex 2538984
SC-L-1x2A-T4-DOL-WM-Ex 2538988
SC-L-1x4A-T4-DOL-WM-Ex 2538992
SC-L-1x6A-T4-DOL-WM-Ex 2538996
SC-L-1x9A-T4-DOL-WM-Ex 2539000
SC-L-1x12A-T4-DOL-WM-Ex 2539004
SC-L-1x16A-T4-DOL-WM-Ex Microprocessor-controlled switchgear in a steel enclosure (IP 54) with LC display and main 2539008
SC-L-1x20A-T4-DOL-WM-Ex switch for level-dependent control of 1 pump within potentially explosive areas with level 2539012
SC-L-1x25A-T4-DOL-WM-Ex sensors or float switches 2539016
SC-L-1x32A-T4-DOL-WM-Ex 2539020
SC-L-1x12A-T4-SD-WM-Ex 2539024
SC-L-1x18A-T4-SD-WM-Ex 2539028
SC-L-1x24A-T4-SD-WM-Ex 2539032
SC-L-1x32A-T4-SD-WM-Ex 2539036
SC-L-1x42A-T4-SD-WM-Ex 2539040
SC-L-1x55A-T4-SD-WM-Ex 2539044
SC-L-1x72A-T4-SD-WM-Ex 2539048

340 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Accessories

Electrical accessories

Electrical accessories – switchgears

Type Description Art no.


SC-L-2x6A-M-DOL-WM-Ex 2538977
SC-L-2x9A-M-DOL-WM-Ex 2538981
SC-L-2x12A-M-DOL-WM-Ex 2538985
SC-L-2x2A-T4-DOL-WM-Ex 2538989
SC-L-2x4A-T4-DOL-WM-Ex 2538993
SC-L-2x6A-T4-DOL-WM-Ex 2538997
SC-L-2x9A-T4-DOL-WM-Ex 2539001
SC-L-2x12A-T4-DOL-WM-Ex 2539005
SC-L-2x16A-T4-DOL-WM-Ex Microprocessor-controlled switchgear in a steel enclosure (IP 54) with LC display and main 2539009
SC-L-2x20A-T4-DOL-WM-Ex switch for level-dependent control of 2 pumps within potentially explosive areas with level 2539013
SC-L-2x25A-T4-DOL-WM-Ex sensors or float switches 2539017
SC-L-2x32A-T4-DOL-WM-Ex 2539021
SC-L-2x12A-T4-SD-WM-Ex 2539025
SC-L-2x18A-T4-SD-WM-Ex 2539029
SC-L-2x24A-T4-SD-WM-Ex 2539033
SC-L-2x32A-T4-SD-WM-Ex 2539037
SC-L-2x42A-T4-SD-WM-Ex 2539041
SC-L-2x55A-T4-SD-WM-Ex 2539045
SC-L-2x72A-T4-SD-WM-Ex 2539049
Accessories without item number are manufactured according to customer specification. More information on request.

Electrical accessories – level control

Type Description Art no.


Signal transmitters for aggressive fluids and fluids containing faeces up to a tempera-
ture of 80 °C. For installing the level controller, either two signal transmitters must be
used, or one switchgear with configurable run-on time (e.g. DrainControl... or EC-
Float switch MS1 Cable length 10 m 2004593
Drain...). Switching Up "On"/ down "Off". Cable length: 10 m. Switching capacity:
250 V / 5 A . When used in potentially explosive areas an Ex cut-off relay must be
provided for the connection!
Signal transmitter for heavily contaminated fluids up to a temperature of 60° C. For Cable length 5 m 6003288
installing the level controller, either two signal transmitters must be used, or one Cable length 10 m 6003287
switchgear with configurable run-on time (e.g. DrainControl... or EC-Drain...). Switch-
Float switch S-Ku
ing Up "On"/ down "Off". Cable length: 5, 10 and 20 m. Switching capacity: 250 V /
1.5 A . When used in potentially explosive areas an Ex cut-off relay must be provided Cable length 20 m 6003286
for the connection!
Accessories
Signal transmitter for slightly contaminated fluids up to a temperature of 60° C. Cable length 10 m 6003292
Switching Up "On"/ down "Off". Cable lengths: 5, 10 and 20 m. Switching capacity: Cable length 5 m 6003294
Float switch S-PS
250 V / 1.1 kW. When used in potentially explosive areas an Ex cut-off relay must be
provided for the connection! Cable length 20 m 6003291
Cable length 10 m 2519924
Level sensor
Cable length 30 m 2519925
0-1 mWS
Cable length 50 m 2519926
Cable length 10 m 2519921
Level sensor Stainless steel housing, protection class IP 68, output signal 4...20 mA,
Cable length 30 m 2519922
0-2.5 mWS ATEX-approved
Cable length 50 m 2519923
Cable length 20 m 6033106
Level sensor
Cable length 30 m 6033107
0-10 mWS
Cable length 50 m 6033108

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 341
Accessories

Electrical accessories

Electrical accessories – level control

Type Description Art no.


Diving bell with 10 m hose length. For connection to Wilo DrainControl PL 1 or PL 2. – 2516976
Dynamic pressure
Diving bell with 20 m hose length. For connection to Wilo DrainControl PL 1 or PL 2. – 2044174
system
Diving bell with 30 m hose length. For connection to Wilo DrainControl PL 1 or PL 2. – 2044313
Bubbling-through system with compressor, non-return valve and T-iron. For con-
Bubbling-through
nection to Wilo DrainControl PL 1 or PL 2, in conjunction with dynamic pressure sys- – 2516977
system
tem.
Zener barrier For the use of a level sensor in potentially explosive areas – 2519928
Accessories without item number are manufactured according to customer specification. More information on request.

Electrical accessories – control and relay

Type Description Art no.


Ex-rated cut-off
For connection of 2 float switches – 2513059
relay (2-circuit)
Ex-rated cut-off
For connection of 3 float switches – 2510698
relay (3-circuit)
Ex-rated cut-off
For connection of 4 float switches – 2510699
‘relay (4-circuit)
Ex-rated cut-off
For connection of 5 float switches – 2510674
relay (5-circuit)
Ex cut-off relay for installation of level control devices with electrodes or float
Ex cut-off relay
switches. Input sensitivity configurable between 2...30 kOhm or 3...300 kOhm. – 6003269
ER 143
Protection class IP 40 (housing), IP 20 (terminals)
Electrode relay ‘ Electrode relay for level control device with electrodes or float switch. Supply voltage:
230 V/50 Hz 6003270
NIV 105/S 120 V/60 Hz or 230 V/50 Hz. For switch cabinet installation!
Electrode relay for connection of external sealing chamber electrode. In addition the
Electrode relay
temperature monitoring (bimetal or PTC sensor) can also be connected. For switch 230 V/50...60 Hz 6045175
NIV 101/A
cabinet installation!
Electronic overload relay for connection of PTC or bimetal temperature sensor, with 230 V/50...60 Hz 6003277
Overload relay
auto-reclosure lockout and Ex-rated. Power supplies: 24 V AC/DC, 120 V/50...60 Hz,
CM-MSS 24 V AC/DC 6049312
230 V/50...60 Hz. For switch cabinet installation!
Evaluation relay with two separately switching changeover contacts for temperature
Evaluation relay
monitoring and control with PT100 sensor. Temperature range -100°C...+500°C, – 6002962
DGW 2.01
triggering 0.1 °C
Phase asymmetry Relay for monitoring the power supply for phase failure, phase asymmetry with LED
– 6003283
relay PS2DF indicator lamp (8...15%) and undervoltage (30%). For installation in switch cabinet
Accessories without item number are manufactured according to customer specification. More information on request.

Electrical accessories – switch cabinets

Type Description Art no.


Two-part cable distribution cabinet for outdoor installation, size 00, made of fibre-
Cable distribution
glass-reinforced polyester. Including integrated mounting plate. Outer dimensions
cabinet two parts – 2523672
(WxHxD): 460 x 830(1760) x 330 Housing with smooth surface. Optional installation
size 00
with selected accessories (additional charge).
Two-part cable distribution cabinet for outdoor installation, size 0, made of fibre-
Cable distribution
glass-reinforced polyester. Including integrated mounting plate. Outer dimensions
cabinet two parts – 2523673
(WxHxD): 590 x 830(1760) x 330 Housing with smooth surface. Optional installation
size 0
with selected accessories (additional charge).

342 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Accessories

Electrical accessories

Electrical accessories – switch cabinets

Type Description Art no.


Two-part cable distribution cabinet for outdoor installation, size 1, made of fibre-
Cable distribution
glass-reinforced polyester. Including integrated mounting plate. Outer dimensions
cabinet two parts – 2523674
(WxHxD): 785 x 830(1760) x 330 Housing with smooth surface. Optional installation
size 1
with selected accessories (additional charge).
Two-part cable distribution cabinet for outdoor installation, size 2, made of fibre-
Cable distribution
glass-reinforced polyester. Including integrated mounting plate. Outer dimensions
cabinet two parts – 2523675
(WxHxD): 1115 x 830(1760) x 330 Housing with smooth surface. Optional installation
size 2
with selected accessories (additional charge).
One-part cable distribution cabinet for outdoor installation, size 00, made of fibre-
Cable distribution
glass-reinforced polyester. Including integrated mounting plate. Outer dimensions
cabinet one part – 2523791
(WxHxD): 400 x 800(1600) x 225 Housing with smooth surface. Optional installation
size 00
with selected accessories (additional charge).
Flashing light Revolving light for installation on switch cabinet, outdoor installation, 1~230 V – 2510429
Signal horn For connection to Wilo DrainControl, 1~230 V – 501459398
Accessories without item number are manufactured according to customer specification. More information on request.

Accessories

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 343
Accessories

Electrical accessories

EC-Drain PD 1 switchgear

Switchgear for level control of 1 submersible wastewater or sewage pump in the series
Wilo-Drain or Wilo-EMU. Level measurement can be performed by the dynamic pressure
system or 2 float switches.

• LED for alarm, operation/run-on time, manual/automatic mode


• Input terminals for connecting 2 float switches (WA 65, WA 95 or MS 1)
• Button for manual mode of the pump
• The switching level and the motor currents are set by potentiometer and DIP switch
• Potential-free contacts for collective fault signal (changeover contact)
• Forced activation of the pump
• Pump switch-off with run-on time (0…120 s)
• Integrated mains-independent alarm buzzer by 9 V rechargeable battery
(available as accessory)

Technical data:
• Operating voltage: 1~230 V or 3~400 V
• Frequency: 50/60 Hz
• Protection class: IP 54
• Dimensions (WxHxD): 190x320x110mm

Attention: Switchgears are not protected against explosions and may only be used outside of
potentially explosive areas. Ex-rated cut-off relays are to be provided for controlling pumps in
potentially explosive areas.

Switchgear Easy Control MS-Lift

Microprocessor-controlled switchgear for level-dependent control of 1 or 2 wastewater or


submersible sewage pumps in direct-on-line starting for wastewater transportation.

Equipment:
• Lockable main switch
• Control panel with buttons
• Display of the current operating or fault conditions via LED
• Motor protection by means of integrated motor current and winding temperature monitoring
• Adjustable follow-up time up to 120 sec
• Pump kick function for 2 sec
• Fault memory
• High water alarm with forced switch-on of the connected pump(s)
• Collective fault signal
• Integrated mains-dependent alarm buzzer (optionally mains-independent via 9V battery)

Inputs:
• 2 or 3 digital inputs for float switches
• 1 or 2 inputs for thermal winding monitoring with bimetal sensor
Outputs:
• 1 potential-free contact for the collective fault signal (SSM)
• 1 potential-free contact for an external alarm signal (2 pump version only)

Technical data:
• Mains connection: 1~230 V or 3~400 V, 50/60 Hz
• Connected power P2: 4.0 kW
• Maximum current: 12 A
• Ambient/operating temperature: -30…+60 °C
• Max. relative humidity: 50 %
• Control voltage: 24 VDC
• Max. switching capacity of alarm contact: 250 V~, 1 A
• Protection class: IP 54
• Electrical safety: Degree of contamination II
• Housing material: Polycarbonate, UV-resistant

Important: Switchgears are not protected against explosions and may be used only outside
potentially explosive areas. The direct connection of pumps within potentially explosive areas
is not possible!

344 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Accessories

Electrical accessories

Switchgear Wilo DrainControl PL 1

Switchgear for controlling the level of 1 submersible pump. Level measurement can be carried
out with either the bubbling-through or the dynamic pressure system, via an electronic level
sensor 0-1 mWs (4-20 mA) or float switch (WA 65, WA 95 or MS1).
• LC display
• LED for alarm, operation/run-on time, manual/automatic mode
• Potential-free contact for collective fault signal and high water alarm
• Forced switch-on of the pump
• Pump switch-off with run-on time (0…180 s)
• Integrated buzzer
• Operating hours counter, pump starts

Technical data:
• Operating voltage: 1~230 V, 3~400 V
• Connected load P2: 4.0 kW
• Frequency: 50/60 Hz
• Protection class: IP 65 (within buildings/switch cabinets)
• Dimensions (W x H x D): 180 x 255 x 180 mm

Attention: Switchgear is not protected against explosions and may only be used outside of
potentially explosive areas. A level sensor in the potentially explosive area (with breakdown
barrier!) or a float switch (in the potentially explosive area with ex-rated cut-off relay) is to be
provided for controlling the pump.
Switchgear Wilo DrainControl PL 1-WS

Switchgear for level control of 1 submersible pump in conjunction with the pumps stations
Wilo-DrainLift WS… . Level measurement can be carried out with either the bubbling-through
or dynamic pressure systems, via an electronic level sensor 0-1 mWs (4-20 mA) or float switch
(WA 65, WA 95 or MS1).
• LC display
• LED for alarm, operation/follow-up time, manual/automatic mode
• Potential-free contact for collective fault signal and high water alarm
• Forced switch-on of the pump
• Pump switch-off with run-on time (0…180 s)
• Integrated buzzer
• Operating hours counter, pump starts
• Lockable main switch
• 3~ mains, no neutral conductor required

Technical data:
• Operating voltage: 1~230 V, 3~400 V
• Connected load P2: 4.0 kW
• Frequency: 50/60 Hz
• Protection class: IP 65 (within buildings/switch cabinets)
• Dimensions (W x H x D): 180 x 255 x 180 mm

Attention: Switchgears are not protected against explosions and may only be used outside of
Accessories
potentially explosive areas. A level sensor in the potentially explosive area (with breakdown
barrier!) or a float switch (in the potentially explosive area with ex-rated cut-off relay) is to be
provided for controlling the pump.

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 345
Accessories

Electrical accessories

Switchgear Wilo DrainControl PL 2

Switchgear for controlling the levels of 2 submersible pumps. Level measurement can be car-
ried out by either the bubbling-through or the dynamic pressure system, via an electronic level
sensor 0--2.5 mWs (4-20 mA) or float switch (WA 65, WA 95 or MS1).
• LC display, multi-language switching
• LED for alarm, operation/run-on time, manual/automatic mode
• Potential-free contacts for collective fault signal and high water alarm, malfunction pump 1,
malfunction pump 2
• Forced switch-on of the pump
• Pump switch-off with run-on time (0…180 s)
• Automatic fault-actuated switchover
• Integrated buzzer
• Operating hours counter, pump starts

Technical data:
• Operating voltage: 1~230 V, 3~400 V
• Connected load P2: 2x 4.0 kW
• Frequency: 50/60 Hz
• Protection class: IP 65 (within buildings/switch cabinets)
• Dimensions (W x H x D): 320 x 300 x 120 mm

Attention: Switchgears are not protected against explosions and may only be used outside of
potentially explosive areas. A level sensor in the potentially explosive area (with breakdown
barrier!) or a float switch (in the potentially explosive area with ex-rated cut-off relay) is to be
provided for controlling the pump.

Switchgear Wilo DrainControl PL 2-WS

Switchgear for controlling the levels of 2 submersible pumps. Level measurement can be car-
ried out with either the bubbling-through or the dynamic pressure system, via an electronic
level sensor 0-1 mWs (4-20 mA) or float switch (WA 65, WA 95 or MS1).
• LC display, multi-language switching
• LED for alarm, operation/run-on time, manual/automatic mode
• Potential-free contacts for collective fault signal and high water alarm, malfunction pump 1,
malfunction pump 2
• Forced switch-on of the pump
• Pump switch-off with run-on time (0…180 s)
• Automatic fault-actuated switchover
• Integrated buzzer
• Operating hours counter, pump starts
• Lockable main switch
• 3~ mains, no neutral conductor required

Technical data:
• Operating voltage: 1~230 V, 3~400 V
• Connected load P2: 2x 4.0 kW
• Frequency: 50/60 Hz
• Protection class: IP 65 (within buildings/switch cabinets)
• Dimensions (W x H x D): 320 x 300 x 120 mm

Attention: Switchgears are not protected against explosions and may only be used outside of
potentially explosive areas. A level sensor in the potentially explosive area (with breakdown
barrier!) or a float switch (in the potentially explosive area with ex-rated cut-off relay) is to be
provided for controlling the pump.

346 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Accessories

Electrical accessories

Switchgear Smart Control SC-Lift

Microprocessor-controlled switchgear for level-dependent control of 1...4 submersible


sewage pumps by means of float switches or level sensors.

> Functions
• 2 operating modes
- "Draining": For draining waste water shafts in water disposal
- "Filling": For filling water tanks and rainwater storage tanks from boreholes in water supply
• Automatic pump alteration
• Test run
• Fault memory for 16 error messages including the type of fault (overflow or dry-running
protection)

> Type key


Example: Wilo-Smart Control SC-L-2x16A-T4-DOL-WM-Ex
• SC-L = Smart Control switchgear for lifting applications
• 2x = Max. number of pumps to be connected
• 16A = Max. rated current for each connected pump
• T4 = Mains connection
• DOL = Start-up type (DOL = direct; SD = star-delta)
• WM = Installation version (WM = wall-mounted installation, BM = ground installation)
• Ex = Version for connection of pumps within potentially explosive areas

> Equipment
• Display of the current operating status and data, as well as faults via the LC display and LEDs
• Symbol-based menu navigation
• Menu navigation and adjustment of operating parameters via operating knob
• Motor protection by means of integrated motor current and winding temperature monitoring
• Direct and star-delta starter
• "Ex" version suitable for connection of pumps within potentially explosive areas

> Inputs
• 1 analogue precision input for level control with level sensor
• 3 digital inputs for level control with float switch
• 1 digital input for low water level with float switch
• 1 digital input for high water alarm with float switch
• Inputs for thermal winding monitoring for bimetal or PTC temperature sensor
• 2 inputs for connecting moisture sensors (e.g.: Motor compartment leakage or sealing cham-
ber control)

> Outputs
• 1 potential-free contact for SSM and SBM
• 1 potential-free contact for high water alarm
• 1 potential-free contact as a signal to start a submersible mixer (pump dependent)
• 1 analogue output 0-10 V, the output of the actual level value
Accessories
> Technical data
• Power supply: 3~ 400V, 50/60Hz
• Max. number of connected pumps: max. 2 pumps with float switch, max. 4 pumps with level
sensor
• Max. rated current: depending on type
• Start-up type: direct or star-delta
• Control voltage: 24 VDC, 230 VAC
• Operating temperature: 0 … +40 °C
• Max. relative humidity: 50 %
• Housing: Coated steel sheeting with cable glands
• Protection class: IP 54
• Electrical safety: Degree of contamination II

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 347
Accessories

Electrical accessories

Level sensor 0-1 mWS

For level measurement.

Technical data:
• Protection class: IP 68
• Measurement range: 0-1 mWS; 0-2.5 mWS
• Cable lengths: 10, 30 or 50 m
• Output signal: 4-20 mA
• Certified explosion approval in accordance with ATEX

Float switch MS1

Signal transmitters for level control devices as min./max switches for fluids that are aggressive
or contain faeces, floats with the fluid and switches when tilted.

Function:
Because of its construction and switching point, the float switch can exhibit only a very small
hysteresis, i.e. the ON and OFF switching points lie close together. This property cannot be
changed, not even the length of the cable. The following points must therefore be noted for
the use of the signal transmitter:
• If only one signal transmitter is used, the connection to the switchgear must be made using a
configurable run-on time, e.g. Wilo-DrainControl…, Wilo-EC Drain…
• The level control device must be fitted with two signal transmitters.

> Technical data


• Max. fluid temperature: 80 °C
• Cable length: 10 m
• Switching capacity: 250 V / 5 A
• Max. pressure: 2 bar
• Switching angle: 10°
• Protection class: IP 68

Float switch S-PS

For level control devices as a min./max. switch for lightly contaminated fluids. Floats up with
the fluid and triggers the switch in inclined position.

The level controller must be permanently positioned on its signal line for the switching point.

Technical data:
• Voltage: 250/400 V
• Rating: 1.1 kW
• Fluid temperature: 60 °C
• Max. pressure: 1 bar
• Protection class: IP 68

348 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Accessories

Electrical accessories

Dynamic pressure system

The pressure transducer (immersion bell) detects changes in the fluid level in the sump. The
change in the pressure value in the immersion bell are transmitted via a leak-proof hose to the
Wilo DrainControl PL switchgear and evaluated by measuring elements in the switchbox.

Scope of delivery:
• Immersion bell with 10 m hose

Bubbling-through system

Dynamic pressure system with compressed air permanently introduced by small compressor.
The immersion bell (dynamic pressure system) is to be ordered separately.

Scope of delivery:
• Mini-compressor
• 3 m hose with T-iron and non-return valve

Ex-rated cut-off relay

For the installation of float switches in potentially explosive areas.


• Suitable for connecting 2 to 5 float switches
- 2-circuit (connection of 2 float switches possible)
- 3-circuit (connection of 3 float switches possible)
- 4-circuit (connection of 4 float switches possible)
- 5-circuit (connection of 5 float switches possible)
1 2 • Installed in an ISO housing, with transparent cover
• Protection class IP 54
• For wall-mounted installation
N L 3 4 5 6 7 8
• Dimensions (W x H x D): 182 x 180 x 165 mm

Accessories

Zener barrier

For the installation of a level sensor in potentially explosive areas.


• Suitable for the connection of a level sensor.
• Protection class IP 40, housing for installation in non-explosive areas.
• Dimensions (W x H x D): 75 x 150 x 106 mm
• 1 m cable premounted.

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 349
Accessories

Electrical accessories

Switch cabinet for outdoor installation

One- or two-part cable distribution cabinet for outdoor installation. Made of fibreglass-rein-
forced polyester including integrated mounting plate. Housing with smooth surface.

Cable distribution cabinet without equipment:


Optional installation with selected accessories (additional charge).
• One-part size 00, protection class IP 34D, outer dimensions (WxHxD): 400 x 800(1600) x 225
for DrainControl PL1 and Easy Control MS-L 1x4kW
• Two-part size 00, protection class IP 44, outer dimensions (WxHxD): 460 x 830(1760) x 330
for DrainControl PL1 WS
• Two-part size 0, protection class IP 44, outer dimensions (WxHxD): 590 x 830(1760) x 330
for DrainControl 1+2 (0.5-10A) DE, PL2 and PL2 WS
• Two-part size 1, protection class IP 44, outer dimensions (WxHxD): 785 x 830(1760) x 330
• Two-part size 2, protection class IP 44, outer dimensions (WxHxD): 1115 x 830(1760) x 330

Cable distribution cabinet including switchgear:


with mounted distribution board, heating and flashing light.
• One-part size 00, protection class IP 34D, outer dimensions (WxHxD): 400 x 800(1600) x 225
optionally including DrainControl PL1 (not water column) or Easy Control MS-L 1x4kW
• Two-part size 0, protection class IP 44, outer dimensions (WxHxD): 590 x 830(1760) x 330
optionally including DrainControl PL2 (not water column), DrainControl 1 (0.5-10A) direct
starter or DrainControl 2 (0.5-10A) direct starter

The switchgears being used have the protection class IP 54.

350 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
&RQVXOWLQJJXLGH

Consulting guide

:HZDQWWRGRPRUHWKDQMXVWRIIHU\RXÞUVWFODVVSURGXFWV
:HDOVRZDQW\RXWREHDEOHWRVHOHFWDQGFRQÞJXUHRXUSXPSV
DQGSXPSV\VWHPVDVHDVLO\DVSRVVLEOH2QWKHIROORZLQJSDJHVZH
KDYHWKHUHIRUHSXWWRJHWKHUVRPHEDVLFLQIRUPDWLRQWRPDNH\RXU
ZRUNHDVLHUIURPWKHYHU\VWDUW,QDGGLWLRQWRFRQFUHWHFRQÞJXUD
WLRQGDWDDQGLQVWDOODWLRQQRWHV\RXZLOODOVRÞQGH[SODQDWLRQVRQ
WKHEDVLFVRIHOHFWULFVDQGK\GUDXOLFVDPRQJVWRWKHUWKLQJV7KLVLV
VXSSOHPHQWHGE\GHWDLOHGLQIRUPDWLRQRQVWDQGDUGVDQGJXLGHOLQHV
DVZHOODVRQOHJDODQGVWDWXWRU\UHTXLUHPHQWV$VDUHVXOW\RXFDQ
EHFHUWDLQWKDWRXUKLJKO\HIÞFLHQWSURGXFWVFDQDOVREHLQWHJUDWHG
KLJKO\HIÞFLHQWO\
Consulting guide

Basic hydraulic principles

Flow rate The following details, among others, are to be observed for system
Solid matter and settling sediments in the sewage may be deposited planning and design in accordance with DIN 1986-100, EN 12050
in pipes, resulting in the clogging of the drainage system. To prevent and EN 12056:
pipe clogging, it is advisable to maintain the following minimum flow • Lifting units are to be designed in terms of performance in such a way
rates: that a minimum flow velocity of Ü 0.7 m/s is guaranteed for the pre-
scribed nominal diameters of the pressure pipe.
Recommendations for flow velocities Required minimum nominal diameters:
Sewage lifting unit for sewage containing faeces without comminu-
Pipe/standard Value according to Recommendation
tion unit: DN 80
standard
Sewage lifting unit for sewage containing faeces with comminution
Free drainage via gravity unit: DN 32
Sewage lifting unit for sewage free of faeces DN: DN 32
Horizontal pipe – Vmin = 0.7... 1.0 m/s Sewage lifting unit for limited use for sewage containing faeces
without comminution unit: DN 25
Vertical
– Vmin = 1.0 ... 1.5 m/s Sewage lifting unit for limited use for sewage containing faeces
pipe
without comminution unit: DN 20
Sewer pipes – Vmin = 2.0 ... 3.0 m/s • The pressure pipe of a lifting unit must be equipped with a non-re-
turn valve and installed with its bottom above the backflow level
Pressure drainage (backflow loop). The pressure pipe may not be connected to waste-
water downpipes.
Pipe flushed with
compressed air 0.6 m/s Û vmin < 0.9 m/s 0.7 m/s Û vmin
• Wastewater gate valves (supply and pressure sides) are to be installed
in accordance with DIN 1986-100, EN 12050/EN 12056.
EN 1671
• Ventilation pipes for lifting units are to be guided to heights above
Non-flushed the roof level; the minimum nominal pipe width is DN 70 for sewage
pipes, ATV- 0.5 m/s Û vmin < 0.9 m/s 0.7 m/s Û vmin Û 2.5 m/s lifting units.
DVWK A 134 • Feed lines are to be installed with sufficient slope (a minimum of
1:50).
Depending on the composition of the fluid (e.g. high sand content, • It is practical to install all pipes flexibly through masonry.
pumping sludge), the above-mentioned values may be higher. How- • An automatic standby pump is to be provided if the sewage disposal
ever, the corresponding regional and national standards and guide- pipe does not allow for interruptions.
lines need to be observed. The flow rate is determined by the full vol- • Switchboxes and signalling systems are to be installed at a dry, easily
ume flow (m³/s) per area (m²) and should generally lie between accessible position. The signalling system is to be mounted at a posi-
0.7 m/s and 2.5 m/s. tion that can be observed.
• Lifting units must be serviced regularly. At least:
The following should be taken into account for the selection of the 1x per year in single-family homes
pipe diameter: Every six months in multi-family homes
The greater the flow velocity, the fewer deposits and the lower the Every 3 months for systems in commercial operations
risk of clogging. But then the resistances in the pipe increase with in- • The installation room is to be provided with sufficient ventilation and
creasing flow velocity, which leads to system inefficiency and can lighting. Above and next to all operating elements and parts to be
lead to premature component damage due to abrasive constituents. maintained there should be a working space of at least 600 mm.
The lifting unit must be fastened so that it is anti-buoyant.
Building services • Sewage containing mineral oils or explosive admixtures must be
Both the sewage generated in a building or on a piece of land and the guided through oil precipitators and/or petrol precipitators; those
rainwater which accumulates on courtyard and roof surfaces should containing fatty substances must go through grease traps and those
be pumped to the sewer system with the aid of pumping stations and with sand through grit chambers. Acidic sewage must be neutralised.
lifting units, insofar as they do not flow naturally downhill into the lo- Pumps are generally to be made with Ex-protection.
cal sewage network. There are different ways of disposing of this
sewage, depending on the respective fluids to be pumped. Wilo sub- Determining the required pump and/or system power
mersible pumps and sewage lifting units are designed especially to Volume flow Qp [l/s]:
meet these different requirements and comply with currently valid Equivalent to the sum of the incoming waste water QS and the in-
EN standards. Planning must be carried out in accordance with coming rainwater Qr, which must be determined in accordance with
DIN EN 12050/12056 – Drainage systems for buildings and sites. A EN 12050/EN 12056:
distinction is made here between sewage emerging from discharge QS = Rate of waste water flow [l/s] from the sum of all sewage sourc-
points above the local backflow level, which must be guided to the es, taking the simultaneity into account, Qr = rainwater flow rate [l/s]
public sewer system by taking advantage of natural slopes, and sew- as a product of rainfall, discharge coefficient and precipitation area.
age from discharge points whose water levels in the anti-siphon trap
lie below the local backflow level. The backflow level is defined in by- Pumping head H/Hman [m]:
laws. The upper street edge is usually taken as a rough guide value. Equivalent to the total height difference (Hgeo in m) between the
Drainage and sewage (rainwater and wastewater), which accumulates lowest collection tank level and the bottom of the backflow loop +
below the backflow level, must be conveyed to the public sewer sys- the total friction losses Hv [m] in the pressure pipe.
tem via automatically operating lifting units – Wilo sewage lifting Attention: When selecting the lifting unit, it is necessary to take into
units or Wilo submersible pumps. account that the pressure difference between the delivery head in
the duty point at the nominal flow rate (observe minimum volume
flow) and the delivery head at zero volume flow must still amount to
approximately 2-3 m in order to open the non-return valve.

352 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Consulting guide

Basic hydraulic principles

Vibration and resonance General notes


When sewage pumps are installed and connected, various aspects • The volume flow to be handled by the pump must exceed the volume
must be observed to guarantee smooth operation. Fundamentally, flow of approaching sewage. Make sure that the pumps run as close
every moving machine part causes vibration. to the optimum duty point as possible to ensure durability and opti-
mum performance.
In the case of submersible motor pumps and monobloc pumps, dur- • Consider a loss in performance with increasing pump age. The volume
ing rotation, free centrifugal forces are generated at the circulation flow and pressures can be negatively influenced by abrasion and cor-
frequency. Also the hydraulic forces acting on the pump impeller rosion.
considerably contribute to machine vibration. • Design the pump so that it operates as efficiently as possible.
• Steep pump curves prevent clogging in the pressure pipe, since when
In order to avoid malfunctions and damage, the strength of vibration there's increased backpressure, the pump also increases pressure
in the operating state must not exceed a certain threshold. This is along its pump curve and rinses away the deposits.
achieved by statically and dynamically balancing the corresponding • When selecting accessories, take the material properties into consid-
parts. eration with regard to the corrosion- and abrasion-resistance.
• Compensate for peak inflows for economical and safety reasons by
If the pumps are subject to additional external vibration due to unfa- using double-pump systems (pump splitting, standby pump is always
vourable installation and connections, this vibration is superimposed. to be considered separately).
This vibration can put high levels of stress on individual components. • If the transfer point (drainage pipe) lies underneath the sump level,
ventilation should be provided, since otherwise the created suction
In order for the pumps to work faultlessly and to have long service could empty the complete sump, incl. the pump. This would result in
lives, they must be installed according to the generally valid rules of ventilation difficulties and should therefore be checked in advance.
technology. • Observe the various operating conditions for pipes which are not per-
manently installed in one place. The partial and full-filling situations
should be observed.

Pipe and pump material


When designing, observe that the following influences could mean
additional requirements for your system:
• Flow velocity of the fluid > Noises, wear
• pH value of the fluid > Material damage, corrosion
• Chemical constituents of the fluid > Corrosion
• Atmospheric conditions, such as humidity, salt content in the air, etc.
> Corrosion
• Outside and fluid temperature > Fluid aggressiveness, corrosion
• Dwell time of the fluid in the pipe > Odour development
• Leakage currents due to using materials having different electron
negativity

Due to the material changes and the resulting pressure level change,
pipes for underground use should be designed as PN 10 pipes.

Consulting guide

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 353
Consulting guide

Pressure losses

Pressure loss in hoses


0,1 1 10 100 200 Q [m³/h]
100 100

Dv Dv
[m] [m]

auch
Schl
m / 2 hlauch

h
lauc

/ A-
-Sch
-Sc
½“

½“
¼“

/ 4“

/ 5“

/ 6“


m/C
m/1

m/1

m/1

m/2

m/B

mm

mm

mm
ø25m

ø32m

ø38m

ø50m

ø52m
ø63m

ø75m

ø102

ø127

ø152
10 10

1 1

0,1 0,1

0,1 1 10 100 200 Q [m³/h]

Q = volume flow; Dv = pressure loss per 100 m hose (kb = 0.25)

354 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Consulting guide

Pressure losses

Pressure loss in fixed pipes

0,4 1,0 2,0 4,0 10 20 40 100 200 400 1000 [m³/h] 6000
30,0 30,0
[m] [m]

20,0 20,0
DN20

DN25

DN32

10,0 10,0
DN40

4,
0
m
/s
8,0 8,0
DN50

6,0 3, 6,0
0
m
5

/s
DN6

4,0 4,0
DN8

00
DN1

2,
25

0
m
DN1

/s
50

2,0 2,0
DN1

00

1,
5
DN2

m
/s
50
DN2

1,0 1,0
00
DN3

0,8 0,8
50

1,
DN3

0
m
00

0,6 /s 0,6
DN4

00

0,
DN5

8
m
/s
00

0,4 0,4
DN6

00
DN7

0,
00

6
DN8

m
/s
00
DN9
000

0,2 0,2
0,
DN1

4
m
/s

0,1 0,1
Consulting guide

0,1 0,2 0,4 1,0 2,0 4,0 10 20 40 100 200 400 [l/s] 1000 2000

Q = volume flow; Dv = pressure loss per 100 m hose (kb = 0.1)

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 355
Consulting guide

Pressure losses

Factors for adapting to other materials/older pipes


kb Pipe type

0.1 new galvanized steel pipes


0.8 newly rolled steel pipes, new plastic pipes
1.0 new cast-iron pipes, bitumen coated cast-iron pipes
1.25 older surface corroded cast-iron pipes
1.5 newly galvanised steel pipes, cleaned cast-iron pipes
1.7 encrusted pipes
2.0 new concrete pipes, medium-gloss
2.5 stoneware pipes
3 new concrete pipes, flat line markings
15-30 cast-iron pipes with light to heavy encrustations

Losses in valves and pipe line contents


Valve type Unit Nominal diameter

DN 40, DN 32, DN 50, DN 65, DN 80, DN 100 DN 150


1¼ 1½ 2 2½ 3

Non-return valve KV m3/h - - 158 267 405 632 1423


Non-return ball valve with flange KV m3/h - - 87 136.5 267 396 890
Non-return ball valve with female thread KV m3/h 26 54 70 115 180 - -
3
Gate valve KV m /h - - 160 280 470 830 2000
Pipe contents l/m 0.8 1.3 2.1 2.9 4.3 8.2 17

Formula for calculating the losses in valves

ΔPV =
( )
Q [m³/h] ²
KV[m³/h]
Q = volume flow in the duty point
KV = Flow coefficient from table

Example
Non-return ball valves with flange, DN 80,
dutypoint 40 m3/h
2
ΔPV = ( )
40 = 0.022 bar = 0.22 m
267

356 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Consulting guide

Installation types

Very different types of installations are used in submersible systems coupling connection is made is such a way that a lip prevents the seal
in municipal applications. The type of installation depends mainly on ring from falling out.
the application purpose and the investment volume.
The pressure pipe made of a galvanized steel pipe, or ideally of a
Basically, three main installation types are distinguished: stainless steel pipe, is fitted directly on the suspension unit via flang-
• Wet well installation, stationary es and leads out of the pump sump. The sump can be made at low
• Wet well installation, portable costs from ready-made concrete sumps equipped with elastomer
• Dry well installation, stationary seals in accordance with EN 1917 (national addition: DIN 4034 T1).
However, one-piece PEHD sumps without joints are a better solution,
The pipe sump installations are also required. The type of installation since these prevent any infiltration of external water.
depends mainly on the requirements of the planning engineer and
the operator. Different viewpoints have arisen, which are each justi- As shown on the diagram alongside, this installation type gives the
fied in terms of the individual field of application. operator the option of special pump sump geometries adjusted to in-
dividual requirements, the use of additional flushing valves or the in-
Wet well installation or stationary tank installation stallation of vortex impellers with special mixer head technology.

The disadvantage of a wet well installation is the lack of ease of


maintenance. In addition, with a wet-installed submersible sewage
pump, the water level can only be lowered to a certain level, since op-
timum cooling of the motor is only possible in submerged condition.

With wet well installation, the pump is installed in the fluid to be


pumped. The motor is cooled by the circulating sewage. The advan-
tage of this type of installation is low investment costs compared to
the more sophisticated pumping station designs for dry-installed
sewage pumps. In such a case, a construction above ground or an in-
termediate base in the sump for the pumps is not required. In greater
depths, an intermediate ceiling is necessary.

The pump is fastened by means of a suspension unit with lowering


mechanism. That allows the pump to be "pulled" at all times, e.g. for
Consulting guide

maintenance work.

The coupling base and the elbow are usually cast in one piece. The
guide consists of two pipes, thus preventing any twisting. The Wilo

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 357
Consulting guide

Installation types

Stationary dry well installation Advantages compared to dry-installed pumps (no submersible
The dry well installation variant, in particular the dry-installed sub- pumps)
mersible pump, provides a number of advantages compared to dry- • Overflow-proof and thus more operational reliability
installed pumps, and also compared to wet-installed submersible • Low-maintenance carbide mechanical seals or seal cartridges
pumps. • No couplings or V-belts, thus fewer wearing parts and less mainte-
nance required
Installation principle of a dry-installed submersible pump • Explosion protection possible at all times
The main difference from a wet-installed submersible pump is the • Clean and hygienic working conditions
design of the motor. It is a fully encapsulated motor with internal • Easy maintenance
closed-circuit cooling. A distinction is made between an open cooling
system and a closed cooling system. With an open cooling system, Portable installation
the fluid to be pumped is used as the coolant. With a closed system
(single-chamber or two-chamber system), cooling is performed by
an external fluid, such as e.g. water-glycol or medical white oil, in a
closed circuit.

Another main difference from the wet-installed submersible pump is


that the dry-installed submersible pump is not installed in the fluid to
be pumped. In terms of the technical construction, an intermediate
base is required directly in the pumping station. The major advantag-
es are the combination. On the one hand, this submersible pump of-
fers all benefits of a dry-installed pump and, on the other hand, all
benefits of a submersible pump, such as being overflow-proof.

As already mentioned, the pump is installed in a separate pump room.


The pump is fastened to the inflow pipe unspectacularly via a pipe el-
bow.

With this type of installation, the motor is cooled in the same way as
for stationary wet well installation, However, the pump is not fas-
tened firmly in the pump by means of a suspension unit. The pump
can thus be installed in any sump via a base component on the pump
housing. With the right couplings, hoses of appropriate length can be
installed on the pressure port. When selecting the pump, hydraulic
conditions, such as volume flow and delivery head as well as the
pump's NPSH, must also be taken into account.

Portable pumps are frequently used as emergency drainage or residu-


al drainage pumps for municipal applications.

358 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Consulting guide

Pumped fluids and impeller shapes

Impeller shapes and properties • Mixed water


To ensure the fluid can be pumped reliably, the correct impeller must • Fluids with problematic constituents and wearing constituents
be used for the corresponding fluid. Each impeller shape has its ad-
vantages and disadvantages here. The following impeller shapes are Single-vane impeller (single-channel impeller)
currently used in our hydraulics:
• Single-vane impeller (single-channel impeller)
• Multi-vane impeller with 2, 3 or 4 channels (multi-channel impeller)
• Vortex impeller
• SOLID impeller
• Propeller impeller (axial impeller)

Single-channel and multi-channel impellers and the SOLID impellers


are available in a closed and half open design. It should be noted here
that the efficiency of the half open design is generally lower than Design: closed and half open
that of the closed design. Recommended nominal diameters: DN 50 to DN 250
Properties:
In addition to the shape of the impeller the level of process reliability • Low-clogging
is also dependent on the nominal diameter of the hydraulics. Vortex • Smooth operation
impellers tend to be used for small nominal diameters (DN 50…150). • Wear-resistant
Multi-channel impellers, on the other hand, tend to be used for large • Steep pump curve
nominal diameters (DN 200...600). • Good efficiency
• Pumping sludge
Furthermore, there are hydraulics which are also equipped with a cut- Fields of application:
ting device or a mechanical stirring apparatus. • Untreated sewage
The additional cutting device breaks up the admixtures in the fluid, • Circulation and heating sludge
thereby facilitating the pumping process. The cutting device is in- • Mixed water
stalled internally or externally depending on the hydraulics selected, • Raw and digested sludge
and it is combined with a half open single-channel impeller or a half • Activated sludge
open multi-channel impeller.
When using the additional mechanical stirring apparatus, the suction Double-vane impeller (two-channel impeller)
area is continuously stirred up. This prevents settlement of the solid
material and the resulting encrustation. Due to the narrowly limited
flow zone of the mixer head only the suction area of the pump is af-
fected. The mechanical stirring apparatus is mostly used in combina-
tion with a vortex impeller.

When using the hydraulics, the following points must be observed:


• The fluid can exhibit a max. dry matter content (DM) of 8%. Design: closed
• The fluid must flow independently of the hydraulics. Recommended nominal diameters: DN 150 to DN 400
• The friction losses in the discharge pipeline and the specific weight of Properties:
the fluid must be taken into account in the calculations. • Low-clogging (depending on nominal diameter and fluid)
• The motor power is to be designed with an adequate reserve for the • Very smooth operation
current operating conditions. • Wear-resistant
• Steep pump curve
Vortex impeller • Good efficiency
• Pumping sludge
Fields of application:
• Rake-cleaned sewage
• Mechanically treated sewage
• Industrial waste water
• Landfill water
• Activated sludge
Recommended nominal diameters: DN 50 to DN 150 • Industrial sewage
Properties:
• Very low-clogging, as it is insensitive to fluids containing fibres and
textiles
• Very smooth operation
• High wear-resistance
• Lower efficiency
• Suitable for pumping gaseous fluids
Consulting guide

• Pumping sludge
Fields of application:
• Untreated sewage
• Activated sludge
• Raw and digested sludge

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 359
Consulting guide

Pumped fluids and impeller shapes

Three and four-vane impeller (multi-channel impeller) Propeller impeller (axial impeller)

Possible pipe diameters: 340 mm, 500 mm and 760 mm


Design: closed Properties:
Recommended nominal diameters: DN 200 to DN 600 • Very smooth operation
Properties: • Very steep pump curve
• Low-clogging (depending on nominal diameter and fluid) • Very good efficiency
• Very smooth operation Fields of application:
• Steep pump curve • Fluids with small amounts of dirt
• Very good efficiency • Rainwater
Fields of application: • Return activated sludge
• Rake-cleaned sewage • Circulation of activated sludge
• Mechanically treated sewage • Water drawing units, etc.
• Industrial waste water
• Landfill water Cutting device
• Activated sludge
• Industrial sewage

SOLID impeller

Design: internal and external


Recommended nominal diameter: DN 32 to DN 40
The properties are dependent on the impeller shape used.
Fields of application:
• Domestic sewage
Design: closed and half open • Wastewater
Recommended nominal diameters: • Faeces
• Closed design: DN 150 to DN 400 • Suitable for low-pressure drainage
• Half open design: DN 80 to DN 150
Properties: Vortex impeller with mechanical stirring apparatus (mixer head)
• Closed design
- Very low-clogging (depending on nominal diameter and flow rate)
- Very smooth operation
- Wear-resistant
- Good efficiency
- Pumping of gaseous fluids
- Pumping sludge
• Half open design
- Hardly any clogging
- Lower efficiency than the closed design Design: external
- Pumping of gaseous fluids Recommended nominal diameter: DN 80 to DN 150
- Pumping sludge Properties:
Fields of application: • High wear-resistance
• Untreated sewage • Lower efficiency
• Industrial waste water • Pumping of gaseous fluids
• Landfill water Fields of application:
• Activated sludge • In the grit chamber
• Industrial sewage • Sand and gravel systems
• Sludge settling ponds
• Sedimentation tanks
• Wherever deposits are possible

360 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Consulting guide

Pumped fluids and impeller shapes

Summary of impeller properties

Impeller properties
No clogging Wear Efficiency Smooth operation Pumping of bub- Sludge
Impeller shape resistance ble-containing pumping
fluids
Vortex impeller +++ +++ o +++ + +
Single-vane impeller ++ ++ ++ + - +
Double-vane impeller + ++ ++ ++ o +
Three and four-
+ + +++ ++ o o
vane impeller
SOLID impeller
+++ ++ ++ +++ + +
(closed)
SOLID impeller
+++ + + + + +
(half open)
Propeller - o +++ ++ o -
+++ = optimum; ++ = very good; + = good; 0 = limited; - = unfavourable

Consulting guide

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 361
Consulting guide

Basic electric principles

Starting current Motor protection relay


This is the current which is required during the start-up operation of Mode of operation:
a machine to overcome friction losses and starting torques. The Thermal protection is provided by bimetals that are heated up by
starting current can be up to seven times that of the nominal current, heating windings through which the motor current flows. A separate
depending on the type of start-up. When there is instability in the bimetal with corresponding heating winding is provided for each
electric mains or for larger motors, corresponding devices must be electrical conductor to the motor. If the current consumption of just
provided to reduce the starting current. These could be soft starters, one winding of the motor exceeds the specified value for several sec-
frequency converters, etc. A reduction of the starting current can al- onds, the bimetal, which is deformed by the heat, triggers the switch
ready be achieved by a motor circuit version in the star delta. lock and switches the motor contactor off. The motor is also shut
down after a short while in the event of a phase failure of the motor
Operating modes (in acc. with DIN EN 60034--1) (uneven heating of the bimetal strips). In the event of thermal trig-
Our motors are generally designed for permanent operation (operat- gering, the switch can only be turned back on again once the bimet-
ing mode S1) in immersed state. For operation with non-immersed als have cooled down. Motor protection relays do not shut the motor
motor (e.g. dry well installation or non-immersed in the sump), the down directly. They only have a contact for a relatively small switch-
motors can be used for permanent operation (operating modes S1), ing capacity. This contact is used to activate a contactor that shuts
short-term operation (operating mode S2) or intermittent operation the motor down in the event of a fault. Unlike the motor protection
(operating mode S3), depending on the design. switch, a motor protection relay does not have a short-circuit trigger.
That is why fuses should be installed in the supply line for one or
The maximum operating times in short-term and intermittent opera- more motors that are protected with a motor protection relay. Fur-
tion are defined by the information in the operating mode, thermore, with motor protection relays, restarting can be set manu-
e.g. S2-15 min or S3 25%. ally or automatically. Restarting should be performed manually, to
prevent constant activation and deactivation if there is a fault.
You can find more information on the individual operating modes in
the separate chapter: "Operating modes". You can find exact infor- Motor protection switch
mation on the possible operating modes of the products on the cor- Motor protection switches can be used to switch the operation of
responding product pages in the technical data. motors on and off. Thermal triggering works according to the princi-
ple of the motor protection relay. However, the operator is able to
Individual run signal shut down the motor during operation or in the event of a fault. Fur-
Indicates the fault of the individual pump and provides an exact eval- thermore, most motor protection switches also have a magnetic fast
uation method for building management systems. trigger mechanism that protects the line downstream and the motor
from short-circuits. In small current ranges, these switches are short-
Explosion protection circuit proof, i.e. a back-up fuse is not necessarily required.
The operator is responsible for marking the explosion zones in the
operating area. The explosion zones are clearly defined in the respec- Other faults that may result in an increase in heat:
tive standards. Products to be used in explosive environments must • Dry running of motors that may only be operated in submerged state
be checked and approved by an external body. The Wilo units are cer- • Unacceptably high fluid temperature / ambient temperature
tified for these applications according to three different standards: • Impermissible running times during short-term operation

• ATEX: European explosion protection standard These faults do not have any effect on the motor's current consump-
• FM: American explosion protection standard tion and can therefore not be detected by the overload protection
• CSA: Canadian explosion protection standard connected upstream. For these types of faults, monitoring devices
are used that are embedded in the component to be protected (mo-
More information on the individual explosion protection standards tor winding). You can find more information on the possible monitor-
and the corresponding classification is to be found in the chapter: ing devices in the chapter: "Motors".
"Explosion protection".
Protective measures (DIN VDE 0100-410)
Ex-rated cut-off relay Protection classes: (DIN EN 50529 / VDE 0470 Part 1)
With ex-rated cut-off relays, float switches can also be used in po- The degree of protection that a housing offers e.g. against direct
tentially explosive environments. These relays reduce the flowing contact is defined by the IP code (International Protection). It con-
current to a magnitude which doesn't cause sparks, even in the event sists of "IP" and two digits (e.g. IP 54).
of an error, which would cause the fluid or its surroundings to ignite.
First figure:
Motor protection • Protection of persons from access to dangerous parts
To operate a motor safely, it must be protected from heating up too • Protection of the equipment from infiltration of solid matter
much. Unacceptable motor overheating can be caused by a fault that
increases the motor current: Second figure:
• Overload • Protection of the equipment from penetration of water
• Phase failure
• Undervoltage
• Blocking
These faults can be detected by a motor protection relay or a motor
protection switch, which then shut down the motor. Motor protec-
tion relay and motor protection switch may not be adjusted to more
than the motor's nominal current.

362 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Consulting guide

Basic electric principles

First figure Second figure


Code figure Guard Protection against foreign bodies Protection against water
0 No protection No protection No protection
1 Protection against contact with back of Protection against solid foreign bodies Protection against water dripping verti-
hand with a diameter of 50 mm cally
2 Protection against solid foreign bodies Protection against water dripping at an
Protection against contact with fingers
with a diameter of 12.5 mm angle (15°)
3 Protection against solid foreign bodies Protection against sprayed water at an
Protection against contact with tools
with a diameter of 2.5 mm angle of up to 60°
4 Protection against solid foreign body Protection against water splashing from
Protection against contact with a wire
with a diameter of 1.0 mm any direction
5 Protection against contact with a wire Dust protection Protection against water jets
6 Protection against contact with a wire Dust-proof Protection against strong jets of water
7 Protection against temporary submer-
- -
sion in water
8 Protection against permanent submer-
- -
sion in water

Consulting guide

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 363
Consulting guide

Motors

Motor cooling
To be able to dissipate the motor heat during operation, a distinction
is made between two constructions:
• Glanded motor
• Self-cooling motor

The glanded motors are filled with air in the motor compartment and
do not have any separate coolant. The heat is dissipated directly to
the surrounding fluid via the housing components.

Figure: Motor with active closed-circuit cooling and two-chamber


system for wet and dry well installation

Figure: Dry motor for wet well installation

These motors can be used in immersed state for permanent opera-


tion. In non-immersed state, the operating mode depends on the size
and on the motor power.

The following series are equipped with glanded motors:


• Drain MTC/MTS
• Drain TC 40, STS 40
• Drain TP 50, TP 65
• Rexa FIT, PRO
• DrainLift S, M, L, XL, FTS
• EMU FA pumps with dry motor

With the self-cooling motors, the waste heat is transferred via a


coolant to the heat exchanger and discharged there to the fluid. With
these motors, a distinction is made between the cooling principle: Figure: Dry motor with active closed-circuit cooling and two-cham-
• Internal closed-circuit cooling: The motor compartment is filled with ber system for wet and dry well installation
oil, which is circulated via an impeller on the shaft.
• External closed-circuit cooling: The motor compartment is filled with
air. A separate cooling system is attached to the motor, and circula-
tion is provided via an impeller or circulation pump.
• Sheath current cooling: The motor compartment is filled with air. A
separate housing is attached to the motor, through which the fluid
flows.

364 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Consulting guide

Motors

• Two mechanical seals in tandem arrangement: Version for high loads


and difficult fluids with two separately installed bidirectional me-
chanical seals for the fluid and the motor.

Figure: Two mechanical seals

• Block seal cartridge: Version for high demands in terms of resistance


Figure: Dry motor with sheath current cooling
to wear and corrosion. Two bidirectional mechanical seals are in-
stalled in the block seal cartridge, arranged face-to-face. Due to the
These motors can be used in immersed state and in non-immersed
installation in a block seal cartridge, the shaft end may be shorter and
state for permanent operation.
replacing a defective seal is easier to perform.
The following series are equipped with self-cooling motors:
• Drain TP 80, TP 100
• FA pumps with FK, FKT and HC motors

Sealing variants
The unit is sealed off against the ingress of fluids on the fluid side and
on the motor side. This sealing can be implemented in different ways:

• On the fluid side with mechanical seal, and on the motor side with ro-
tary shaft seal: Basic version for normal applications with a bidirec-
tional mechanical seal on the fluid side and a rotary shaft seal to the
motor.

Figure: Block seal cartridge

Monitoring equipment
The integrated monitoring units are for protecting the motor:

• Excess temperature in winding/bearing/oil


• Over pressure in the motor
• Ingress of water in
- Sealing chamber
- Leakage chamber
- Motor compartment
- Clamping space
Figure: Basic sealing The possible sensor equipment depends on the different motor
types. The individual sensors will be described below.

Bimetal temperature sensor


Bimetal temperature sensors are mechanical switches which trigger a
switching operation as a result of the heat. "Normally closed con-
tacts" are used, i.e. when the tripping temperature is reached, the
Consulting guide

electrical circuit is interrupted. When the temperature drops accord-


ingly (hysteresis), the sensor closes automatically again. 2 or 3 tem-
perature sensors are installed in series in the windings. Another appli-
cation option is the monitoring of the oil temperature in oil motors. In

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 365
Consulting guide

Motors

Ex motors for submerged operation and in special versions, there are motors that have an oil-filled motor compartment. "Normally closed
2 temperature circuits with different tripping temperatures. contacts" are used, i.e. when an over pressure builds up in the motor,
the electrical circuit is interrupted.
Application for the following:
• Slowly rising temperatures, e.g. obstruction of cooling by deposits No special relay is required for the evaluation.
• Overload
• Surfacing of motors that may only operate in submerged state Thermal float switch
• Unacceptably high ambient temperatures Thermal float switches are mechanical switches that trigger a switch-
• Operating time too long in S2 operation ing operation in the event of a low oil level or if the temperature in
the motor is too high. They are used in motors that have an oil-filled
Thermistor/PTC motor compartment. "Normally closed contacts" are used, i.e. if there
PTC thermistor sensors are temperature-sensitive resistors. These is a lack of oil or if the temperature of the oil is too high, the electrical
sensors do not have any mechanical components. When the nominal circuit is interrupted.
activation temperature (NAT) is reached, the electrical resistance of
the sensors increases rapidly. This change is evaluated by an elec- No special relay is required for the evaluation.
tronic switchgear. 3 temperature sensors are installed in series in the
windings. In large machines and special versions, there are 2 temper- Conductive electrodes
ature circuits each with different tripping temperatures Conductive electrodes (based on the measurement of the resistance)
(e.g. 130/140 °C). A switchgear (e.g. WILO CM-MSS) is required for are used to evaluate conductive fluids. The sensor consists mainly of
each temperature circuit. a rust-proof electrode rod. It is used to measure the conductivity of
the fluid in relation to a reference earth (motor housing). This change
Application for the following: is evaluated by an electronic switchgear (e.g. Wilo NIV 101). The
• All types of temperature protection switching resistance is determined by the setting on the switchgear,
• Blocking of sewage motors not by the sensor.
• Motors for speed control (specification for Ex motors on the convert-
er) A special electrode relay is always required, e.g. Wilo NIV 101/A,
NIV 105/S or ER 143 (for potentially explosive areas). The sensitivity
PT 100 temperature sensor of the relay is to be set to > 20 kũ.
PT 100 sensors are temperature-dependent resistors with an almost
linear pump curve. At 0 °C, the resistance is 100 ũ. The resistance
difference between 0 and 100 °C is 0.385 ũ/K. This change is evalu-
ated by an electronic switchgear (e.g. WILO DGW 2.01 G). The
switching temperature is determined by the setting on the switch-
gear, not by the sensor. In addition to the adjustment of the switch-
ing points, the temperature can also be measured.

Application for the following:


• Slowly rising temperature
• e.g. cooling obstructed by deposits
• Overload
• Surfacing of motors that may only operate in submerged state
• Unacceptable ambient temperature
• Longer running time in S2 operation
• Blocking only to a limited extent

In order to be able to compensate the fault caused by the line resist-


ance, the connection is usually established in the form of three-wire
switching. Almost all PT 100 evaluation relays support this connec-
tion.

Leakage floater
Leakage floaters are mechanical switches that trigger a switching op-
eration in the event of fluid penetration. Therefore if fluid penetrates
the leakage chamber via the second mechanical seal, the motor can
be shut down or a warning emitted. "Normally closed contacts" are
used, i.e. if fluid enters the leakage chamber, the electrical circuit is
interrupted.

No special relay is required for the evaluation. The switching capacity


of the floater contacts deviates with different motor types and must
therefore be taken from the connection diagram for the respective
motor.

Pressure switch
Pressure switches are mechanical switches that trigger a switching
operation in the event of over pressure in the motor. They are used in

366 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Consulting guide

Operating modes

The operating mode determines the permissible duty cycle of motors. S2 Short-term operation
One should always make sure that the built-in temperature control of Definition
the motors is connected correctly. It ensures that the temperature Operation at constant load and with a duration that is not sufficient
classes of the windings are adhered to in the event of the operating to reach the thermal state of inertia, and a following standstill time,
time being exceeded or the wrong operating mode. during which the fallen machine temperatures only deviate from the
temperature of the coolant by less than 2 K.
S1 Permanent operation
Definition: The power dissipation of the machine is higher than can be dissipated
Operation at a constant load until the machine can reach the thermal via the coolant. In S2, the permissible operating time is always also
state of inertia. specified (e.g. S2 15 min). After this operating time, the machine
must cool down again to the ambient temperature. This operating
The machine is designed in such a way that cooling is sufficient at the mode is mainly used for dry-installed machines.
specified conditions. The operating mode does not give any informa-
tion as to whether the machine is to be operated dry or wet. If no op- P
erating mode is specified on the rating plate of a machine, S1 perma-
nent operation applies.
P

t
PV

t
PV

t Θ

Θmax

Θmax

ΔtP

t
Consulting guide

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 367
Consulting guide

Operating modes

S3 Intermittent operation without affecting the starting current


Definition
Operation that consists of a sequence of identical cycles, each one
consisting of an operating time with constant load and a downtime,
and the starting current does not have a significant effect on the ex-
cess temperature.

The power dissipation of the machine is higher than can be dissipated


via the coolant. In S3 operating mode, the cycle duration is specified
in percent and the cycle time is also specified.

Example for S3 25% 10 min: The activation period is 2.5 min. and the
pause is 7.5 min. If no cycle duration is specified, a cycle duration of
10 min. applies.
P TC
ΔtP ΔtR

t
PV

Θmax

P= load
PV= electrical losses
ř= temperature
řmax= max. temperature
t= time
TC = cycle duration
ŕtp= operating time at constant load
ŕtR= standstill time with no current in windings, relative activation
period = ŕtP/TC

368 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Consulting guide

Level measuring systems

Level measuring systems are for measuring the water level in tanks. Single-point float switch:
Depending on the application conditions, various systems are availa- These floaters are fastened very shortly to the cable and have a slight
ble. difference between activation point and deactivation point. Some of
these floaters are also available as heavy versions that tilt around
Float switch their centre of gravity. To avoid the constant switching of the pump,
With this method, switching contacts are closed or opened in a float- at least two of these floaters must be used for level control. Due to
ing body according to the inclination angle. With float switches, one their good floating properties, however, they are better suited for
should always make sure that they can move freely in the sump. They sewage applications.
can also be used in potentially explosive areas if operated via an ex-
cut-off relay (Ex-i).

Two-point float switch:


These float switches have a larger angle between activation point
and deactivation point. They are fastened to their pipe. That makes it
possible to switch smaller differences with only one float switch ac-
cording to the drawn-out pipe length.

0
A basic distinction must be between two different designs:
Consulting guide

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 369
Consulting guide

Level measuring systems

Dynamic pressure system (measurement of the hydrostatic pres- Pressure probe (electronic pressure transducer)
sure) Like the velocity head probes, the hydrostatic pressure is measured at
With this method, a measuring bell / velocity head bell is used to the installation point here, too. However, a diaphragm is used here to
measure the pressure at the point of installation. The filling height of convert the pressure in the pressure transducer directly into an elec-
the fluid generates a pressure that is forwarded to the evaluation unit trical signal.
via a hose. In the evaluation unit, the pressure is converted into an
electrical signal. That enables the continuous measurement of the
filling level, and the switching points can be freely defined.

Conductivity (conductive measurement method)


In this case, submersible electrodes are connected to an evaluation
relay. The relay detects whether fluid is present or not based on the
A distinction is made between open systems and closed systems. The resistance. The trigger resistance can be set on most relays. In this
selection depends on the field of application and the type of fluid. way, simple level controls for filling or draining can be implemented.
The application in potentially explosive areas is possible. The application as a dry-running protection system is also very fre-
quent. Not suitable for sewage pumping stations.
Open system:
With this version, the bell is open in the direction of the fluid. Every
time the fluid is pumped out, the bell must surface to vent the sys-
tem. It is switched "Off" after a certain time. Another way to vent the
system is by connecting to a small compressor (bubbling-through
system), that vents the system constantly or periodically. Its "Off"
state depends on the water level.

Closed system:
With this version, the air cushion in the bell is separated from the fluid
by a diaphragm. The system is therefore suitable for heavily contami-
nated fluids. Leakages / air loss in the system result in measuring er-
rors or a system malfunction.

370 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Consulting guide

Level measuring systems

Ultrasound
Measurement with ultrasound is based on the measurement of the
running time. The ultrasonic pulses emitted by a sensor are reflected
from the surface of the fluid and detected by the sensor. The required
running time is a measure for the distance covered in the empty tank.
This value is deducted from the overall tank height, which results in
the filling level.

The advantage of this method is that measurement of the filling level


in the tank is possible without contact, regardless of the fluid. During
installation, one should ensure that the measuring cone emitted by
the sensor is free of installations. A minimum clearance to the wall of
the tank must also be kept.

Consulting guide

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 371
Consulting guide

Explosion protection

For applications in explosive environments, the products must be The explosion classification defines the following:
checked accordingly by a certified body and approved. For these ap- Class 1 Division 1; groups C, D
plications, the Wilo units are certified according to three different Meaning: Gases, fumes, mist; ex-atmos-
standards: phere constantly or occasionally present
under normal conditions; gas groups: Eth-
• The European ATEX standard ylene (C), propane (D)
• The American FM standard
Class 2 Division 1; groups E, F, G
• The Canadian CSA standard
Meaning: Dust, ex-atmosphere constantly
or occasionally present under normal con-
The three different standards are described briefly below, including
ditions; dust groups: Metal (E), carbon (F),
what you need to observe for applications in explosive environments.
grain (G)
For the standard according to which the individual series are checked Class 3 Description: Fibres and lint
and approved, please refer to the technical data on the corresponding
product pages. The explosion classification and the approval number T3C Temperature class
are to be found on the rating plate or in the installation and operating Meaning: max. surface temperature of the
instructions. machine of 160 °C

ATEX standard
The units are designed according to "EC directive 94/ 09/EC" (ATEX CSA standard
95) and the European standards DIN EN 60079-0and EN 60079-1. The units are certified by the certified testing and licensing authority
They may be operated in potentially explosive atmospheres which “KEMA” (European registration office for CSA) in accordance with the
require electrical devices of device group II, category 2. current standards. The units are approved according to the zone and
class system.
It is therefore possible to use them in zone 1 and zone 2. These units
may not be used in zone 0. Approval according to zones
They may be operated in potentially explosive areas which require
The explosion classification, e.g. II 2 G Ex d IIB T4, defines the follow- electrical devices of protection class "Explosion-proof, Class 1, Zone
ing: 1". Therefore, operation in areas with the required protection class
II Device group II "Explosion-proof, Class 1, Zone 2" is also possible.
Meaning: intended for places where explo-
sions may occur, with the exception of The explosion classification, e.g. Ex d IIB T4 Gb, defines the following:
mines Ex Ex-protected device in accordance with
2 Category IEC standard
G Substance group d Motor housing ignition protection class
Meaning: Gases Meaning: Pressure-proof enclosure
Ex Ex-protected device in acc. with European IIB Explosion group
standard Meaning: for use in combination with gas-
es of subdivision B, all gases with the ex-
d Motor housing ignition protection class
ception of H2, C2H2, CS2
Meaning: Pressure-proof enclosure
T4 Temperature class
e Terminal ignition protection class
Meaning: max. surface temperature of the
Meaning: increased safety
device is 135 °C
IIB Explosion group
GB Device protection level "B"
Meaning: for use in combination with gas-
es of subdivision B, all gases with the ex-
Approval according to classes
ception of H2, C2H2, CS2
They may be operated in potentially explosive areas, which require
T4 Temperature class electrical devices of protection class "Explosion-proof, Class 1, Divi-
Meaning: max. surface temperature of the sion 1". Therefore, operation in areas with the required protection
device is 135 °C class "Explosion-proof, Class 1, Division 2" is also possible:
GB Device protection level "B"
The explosion classification defines the following:
Class 1 Division 1; groups C, D
FM standard Meaning: Gases, fumes, mist; ex-atmos-
The units are certified and approved by the recognized testing and li- phere constantly or occasionally present
censing authority "FM Approvals" according to standards FM 3600, under normal conditions; gas groups: Eth-
3615, 3615.80 and ANSI/UL-1004. They may be operated in poten- ylene (C), propane (D)
tially explosive areas which require electrical devices with the protec-
T3C Temperature class
tion class "Explosionproof, Class 1, Division 1". Therefore, operation
Meaning: max. surface temperature of the
in areas with the required protection class "Explosion-proof, Class 1,
machine of 160 °C
Division 2" according to the FM standard is also possible.

372 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Consulting guide

Explosion protection

Temperature monitoring
Standard explosion-certified motors must equipped with a tempera-
ture monitoring option. This monitoring can take place using bimetal
strip sensors or PTC sensors.

The standard temperature monitoring unit is always designed as a 1-


circuit monitoring unit, i.e. when the maximum winding temperature
is reached, the motor must be switched off!

The temperature monitoring unit can be designed as an optional 2-


circuit monitoring unit, i.e. when the lower temperature is reached, a
preliminary warning is emitted. Deactivation is only necessary if the
maximum winding temperature is reached.

The temperature monitoring unit must be connected in such a way


that when the maximum winding temperature is reached, the motor
is deactivated and reactivation is only possible if the release button
was actuated manually.

When the lower temperature is reached (2-circuit monitoring), a pre-


liminary warning is possible or deactivation with automatic reactiva-
tion.

Non-immersion of the motor in the sump or dry well installation of


dry motors
These motors may only be non-immersed or dry well installed if there
is a 2-circuit temperature monitoring unit!

Frequency converter operation


For operation on a frequency converter, it must be ensured that the
internal winding temperature monitoring unit (bimetal strip sensor or
PTC sensor) can be connected.

Sealing chamber control


The units can be equipped with an external sealing chamber control.
This can also be retrofitted. If the unit is equipped with external seal-
ing chamber control, it must be connected to an intrinsically-safe
electric circuit.

Ex-zone definitions
The Ex-zones are clearly defined in the respective standards. The
identification of the zones in the operating area of the units must be
performed by the operator. When ordering, indicate which Ex stand-
ard you are using and in which zone you would like to operate the
unit.

Consulting guide

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 373
Consulting guide

Materials

Abrasite properties with good temperature resistance. The material is also


Special material for pump housings and impellers. This is a high-alloy, highly resistant to organic solutions.
extremely wear-resistant cast material. The material has a martensit-
ic basic structure with a high chromium and mixed carbide content. It Stainless steel 1.4404 - V4A (AISI 316L - X2CrNiMo17-12-3)
provides an especially high degree of wear resistance against sewage, V4A comes from the Thyssen Krupp definition (test series 4, type
which has a high concentration of abrasive particles (such as waste- Austenite) and refers to a high-alloy rustproof steel (as compared to
water with a high proportion of sand, for example). Lab tests show 1.4301) with a molybdenum content, which can sometimes also be
that "Abrasite" provides a seven times longer pump service life for used in seawater. High strength and high elasticity are the features
abrasive materials compared to normal cast materials. which make stainless steel superior to grey cast iron.

Concrete Grey cast iron


Material for creating sumps in accordance with DIN 4034-1. The con- Grey cast iron is the standard material used in pump construction. For
crete quality used by Wilo complies with DIN EN 206 (formerly DIN many years now, most units are made of grey cast iron. The benefits
1045). The exact designation is B45WU with a maximum water pene- of grey cast iron are mainly its price and robustness. In the field of
tration depth of 30 mm as specified in the standard. The following are submersible pumps, the cast materials EN-GJL-250 and EN-GJS-
aggressive toward concrete: Fluids with pH values < 6.5, sulphuric ac- 500-7 are primarily used.
id, hydrochloric acid, butanoic acid and lactic acid, sulphates, salts,
animal and mineral fats and oils. PE-HD (high density polythene)
The most frequently used material in pipe construction for sewage
Ceram pipes with very high chemical resistance and extremely low surface
Ceram coating provides modern corrosion and abrasion protection. It roughness for preventing deposits and flow losses. High impact re-
is based on aluminium oxide particles enclosed in a polymer matrix. sistance and ultimate strain with low influence of temperature are
Its structure is based on the diamond model and combines two im- other advantages. The material PE100 is used increasingly in practice
portant properties: there are no predetermined breaking points and and is replacing PE80 and grey cast iron. Benefits, such as installing
the adhesion is very high. The coating is available in five different pipes during renovation work, offer a high cost-savings potential..
qualities: C0, C1, C2, C3 and CT. For use in highly abrasive fluids, the
coatings C1 to C3 can also be combined in order to establish an even PP (polypropylene)
higher degree of protection. Resistance to extreme temperatures and chemicals and an extremely
high stability (due to the high impact strength of the material) char-
Duplex steel (1.4517, 1.4460, 1.4462) acterise this material.
Its microstructure consists of a ferritic matrix, in which austenitic in-
clusions are embedded. The ferrite/austenite ratio is normally 50:50. PUR (polyurethane)
This duplex microstructure combines the beneficial properties of PUR is available in many variations. The outstanding advantages of
rustproof ferritic and austenitic materials. It has good mechanical Baydur GS, which is used by Wilo and has been proven in industrial
properties and a significantly higher resistance to corrosion. The du- applications, such as the high chemical resistance to diluted acids, al-
plex steel 1.4460 and 1.4462 and the cast stainless steel material kaline solutions, motor oils, greases, benzines, etc. as well as the cor-
1.4517 are relatively widespread. Compared to chromium-nickel- rosion- and micro-resistance, are predestined for use in aggressive
molybdenum steel, these materials have a better general resistance media. It is also characterised by its superior wear resistance, resist-
to corrosion. In addition, they are much more resistant to pitting cor- ance to rotting, weather resistance, dimensional stability under heat
rosion, contact corrosion and stress corrosion cracking and are to a and impact resistance at a much lower weight compared to metallic
large extent resistant to intercrystalline corrosion. Lab tests show materials, such as grey cast iron. In a sand-slurry test conducted by
that the duplex material 1.4517 provides a significantly longer pump Bayer, the wear resistance or PUR is about twice as high as that ofcast
service life for pumping abrasive fluids compared to normal cast ma- iron under the same conditions.
terials (more exact data is available in the sand material speed recom-
mendation table, MH07.2006). PVC (polyvinyl chloride)
PE sumps are designed in accordance with DIN 19537-1 and offer
Stainless steel 1.4301 - V2A (AISI 304 - X5CrNi18-10) great advantages compared to conventional concrete sumps, such as
V2A comes from the Thyssen Krupp definition (test series 2, type durability, flexibility, easy installation and reduced installation costs.
Austenite) for a chrome-nickel steel. This is the steel standard which It is a flame-resistant material, which equally combines mechanical
is generally available in the pump industry, combining good strength strength and chemical resistance.

Material table for austenitic steels

DIN designation US designation Chemical symbol European standard American standard


Material number AISI EN ASTM
1.4301 304 X5CrNi18-10 10088-3 A 167 /276
1.4401 316 X5CrNiMo17-12-2 10088-3 A 167 /276
1.4404 316 L X2CrNiMo17-12-3 10088-3 A 167 /276
1.4571 316 Ti X6CrNiMoTi17-12-2 10088-3 A 167 /276

374 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Consulting guide

Materials

Material table for duplex materials

DIN designation US designation Chemical symbol European standard American standard


Material number AISI EN ASTM
1.457 G-X2CrNiMoCuN25-6-3-3 10213-4 / 10283 A 351 / 744 / 890 / 995
1.4460 329 X-3CrNiMoN27-5-2 10088-3-2005 S32900
1.4462 2205 X-2CrNiMoN22-5-3 10088-2-2005 S31803

Material table - Properties

Designation Service temperature Resistant Non-resistant Application areas


[°C]
Seal materials
EPDM Water without chemical additives,
Fuels,
caustic sodas,
kerosene, Housing seals,
-30...+120 hydrochloric acid,
sulphuric acid, Mechanical seal bellows
phosphoric acid,
nitric acid
salt water
FPM (= Viton) Sewage pH 3 to pH 10,
Acetic acid,
fuels, Housing seals,
-25...+120 nitric acid,
mineral oils, Mechanical seal bellows
benzol
phosphoric and sulphuric acids
NBR Sewage pH 6 to pH 10,
water without chemical additives,
Nitric acid, Housing seals,
-30...+100 fuels,
sulphuric acid Mechanical seal bellows
mineral oils,
salt water
Housing and peripheral materials
Abrasite Pump housings,
Sewage with
-25...+200 Acids impellers,
abrasive constituents
mixer head
Stainless steel 1.4301 Seawater*,
Mineral oils, Motor housings,
hydrochloric acid,
-20...+120 water without chem. additives, hydraulics housings,
concentrated acids and
alcohols impellers
alkaline solutions
Stainless steel 1.4404 Seawater*,
Mineral oils, Motor housings,
hydrochloric acid,
-20...+120 water with chem. additives, hydraulics housings,
concentrated acids and
alcohols impellers
alkaline solutions
PE Pump housings,
Sewage pH 4 to pH 9, impellers,
Concentrated acids and
0...+90 water without chem. additives, pipes,
alkaline solutions
inorganic dilute fluids pump sumps,
fitting ducts
PP Pump housings,
Sewage pH 4 to pH 9,
Concentrated acids and impellers,
0...+90 water without chem. additives,
alkaline solutions non-return valves,
inorganic dilute fluids,*salt water
pump sumps
PUR Seawater*,
acids,
Pump housings,
bases,
Highly aggressive impellers,
0...+80 pH 3 to pH 13,
acids and bases connection elements, ag-
fats,
itators
machine oils,
benzine
* Conditionally resistant depending on the fluid temperature and other organic and inorganic fluid constituents
Consulting guide

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 375
Consulting guide

Ceram coating

Modern corrosion and abrasion protection Ceram coatings are available in four different quality levels. These are
Units that come into contact with the fluid are subject both to highly distinguished in terms of their resistance to abrasive corrosion. While
corrosive as well as abrasive influences. For this, Wilo offers its Ceram corrosion resistance is very good for all four quality levels, resistance
coating. This provides reliable protection against this type of stress. to abrasion increases the higher the ordinal number (C0 = low pro-
tection from abrasion; C3 = very good protection from abrasion) of
Normal heavy corrosion protection methods, such as zinc dust prim- the coating, since coarser aluminium particles are processed. The in-
ing with three coats of tar epoxy resin are called onion layer models. dividual layers get thicker and the mixture of large, medium-sized
The advantage of zinc dust priming is that the zinc dust sacrifices and and small aluminium oxide particles is such that even in the case of
the zinc carbonate can seal microscopic cracks. This is referred to as abrasion with fine sand, the coatings are very stable.
the self-healing effect of the coating. The disadvantage is that the
wet adhesion of this zinc dust priming isn't very high. Because of the • Ceram C0: The coating is applied using the airless method in one lay-
onion layer model of conventional solvent-containing coatings, the er of 0.4 mm.
adhesive force depends on the quality of the individual layers. • Ceram C1: The coating is applied with a paintbrush and may consist
of up to three layers. The layer thickness is 1.5 mm.
The Ceram coating, on the other hand, is based on the diamond mod- • Ceram C2: The coating is applied with a spatula. The layer thickness is
el. It unifies the positive properties of two materials by combining 1.5 mm and consists of one coat.
aluminium oxide particles in one polymer matrix. The aluminium ox- • Ceram C3: The coating is applied with a spatula. The layer thickness is
ide particles are enclosed in the matrix. Thus, there are no predeter- 3 mm and consists of one coat. For tight gaps/clearance, a mechani-
mined breaking points and the adhesion is very high, e.g. in the case cal process is necessary.
of Ceram C0 15 N/mm2. Since Ceram is solvent-free, these coatings
can be applied with one layer. For use in special fluids, the individual Ceram qualities can be com-
bined with one another, e.g. C2 + C1.

Structure of different coatings

3 2

1 1

1.) Basic material e.g. housing in cast iron 1.) Basic material e.g. housing in cast iron
2.) 1st coating: zinc dust priming (50 rm), adhesiveness 2.5 N/mm2 2.) 1st coating: Ceram C0 (400 rm), adhesiveness 15 N/mm2
3.) 2nd to 4th coating: tar epoxy resin (110 rm), adhesiveness 5 N/mm2 This illustration shows the structure of a Ceram C0 coating. The coating con-
The illustration shows the structure of a tar expoxy resin coating with zinc dust sists of a one individual layer with a total layer thickness of 400 rm. The airless
priming. The coating consists of 4 individual layers with total layer thickness of application method allows a very high surface quality.
380 rm. The three lines in dark grey represent the weak points of this coating,
the black line shows the predetermined breaking point.

376 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Consulting guide

Ceram coating

The Ceram coating is also very well suited for use in maritime envi-
ronments. For its Ceram C0 coating, Wilo grants a guarantee of 5
years for use in seawater. The prerequisite is that the coating is intact

Increase efficiency, reduce costs


Since water is being used more and more economically, the propor-
tion of contaminants is increasing relative to the amount of water.
This means that the concentration of corrosive and abrasive constit-
uents is higher.

Sewage units are always exposed to this aggressive fluid. Corrosion


and abrasion affect the surfaces and material structures of the units,
sometimes with considerable impairments to the material, and thus
also the performance.

This significantly reduces the hydraulic efficiency. This results in the


units having an increased current consumption. On the other hand,
the pumps no longer work at their optimum, the radial forces in-
crease, there is more stress on the bearings and mechanical seals, and
the service life of the machines is reduced.

When standard materials are used, such as grey cast iron, under high
stress, it may be necessary to exchange the components already after
500 hours of operation. Ceram coatings allow the service life to be
increased by a factor of 4, and this at the same high efficiency, which
means minimum energy costs.

If one takes the overall costs over the entire service life of the pump
into account, the investment costs for a unit coated with Ceram are
less than 10%, and thus negligible. On the other hand, there is a high
savings potential due to the fact that fewer repairs are required, re-
sulting in a significant reduction of system downtimes. The amortisa-
tion is then usually quickly reached due to the higher efficiency.

Use of the various Ceram qualities


• Ceram C0 is used for the complete outer and inner coating. It's ideally
suited for corrosion protection.
• Ceram C1 is used for the inner coating of pump components. The
main field of application is the coating of the impeller and the suction
port .
• Ceram C2 and C3 are used for the inner coating of pump components.
The main field of application is the coating of the pump housing.

In order to guarantee protection even in especially aggressive and


corrosive fluids, the Ceram types are combined with each other, e.g.
C2 + C1 or C3 + C1.
Consulting guide

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 377
Consulting guide

Ceram coating

Ceram C0 - Technical data Resistance table


Description
Ceram C0 is a sprayable, solvent-free two-component polymer coat- Fluid Temperature Factor
ing substance with an aluminium oxide basis for protecting our prod- Sewage, alkaline (pH 11) +20 °C 1
ucts against corrosion when there is additional strong mechanical Sewage, alkaline (pH 11) +40 °C 1
stress.
Sewage, slightly acidic (pH 6) +20 °C 1
Composition Sewage, slightly acidic (pH 6) +40 °C 1
Solvent-free epoxy polymer with solvent-free polyamine hardener Sewage, highly acidic (pH 1) +20 °C 2
and various extenders. Sewage, highly acidic (pH 1) +40 °C 3
Features Ammonium hydroxide (5%) +40 °C 3
• Tough and durable coating with high mechanical and chemical resist- Decanol (fatty alcohol) +20 °C 1
ance and very good abrasion resistance. Decanol (fatty alcohol) +50 °C 1
• Excellent wet adhesion and compatibility with cathodic corrosion Ethanol (40%) +20 °C 1
protection as single-layer coating on steel surfaces.
• Very good adhesion to steel surfaces. Ethanol (96 %) +20 °C 3
• Replaces bituminous coatings. Ethylene glycol +20 °C 1
• Saves costs due to the long service life, low maintenance and easy Heating oil/diesel +20 °C 1
repair ability. Compressor oil +20 °C 1
• Tested by the "Bundesanstalt for Wasserbau" (German Federal Insti-
tute for Hydraulic Engineering) (BAW). Methyl ethyl ketone (MEK) +20 °C 3
• Solvent-free. Caustic soda (5%) +20 °C 1
• Hardened coating has a high-gloss finish. Caustic soda (5%) +50 °C 2
Sodium chloride solution (10%) +20 °C 1
Technical data Hydrochloric acid (5%) +20 °C 2
Density (mixture) adhesive ASTM D 792 1.4 g/cm3 Hydrochloric acid (10 %) +20 °C 2
strength/steel ISO 4624 15 N/mm2 Hydrochloric acid (20 %) +20 °C 3
Impact resistance / strength DIN EN ISO 6272 9J Sulphuric acid (10%) +20 °C 2
Temperature resistance: dry, 60 °C Sulphuric acid (20 %) +20 °C 3
long-term Nitric acid (5%) +20 °C 3
Temperature resistance: dry, 120 °C Toluene +20 °C 2
short-term
Water (cooling/industrial water) +50 °C 1
Temperature resistance: wet
Depending on the fluid; on request Xylene +20 °C 1
/ liquid
Solid content Volume 97 % Key: 1 = resistant; 2 = short-term resistant; 3 = overflow resistant,
(mixture) Weight 98 % immediate cleaning; 4 = not recommended for direct contact

378 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Consulting guide

Ceram coating

Ceram C1 - Technical data Resistance table


Description
Ceram C1 is a cold-hardening, solvent-free composite material based Fluid Factor
on two components with selected reinforcement fillers and extend- Acids
ers. Sulphuric acid (10%) 2
Composition Sulphuric acid (20 %) 3
Polymer/aluminium oxide composite material made of a base com- Hydrochloric acid (5%) 1
pound and reinforcement. Hydrochloric acid (10 %) 2
Base compound: a modified polymer consisting of two components Hydrochloric acid (20 %) 3
with an aliphatic hardening agent.
Reinforcement: a mixture (protected by proprietary rights) made of Nitric acid (5%) 1
aluminium oxide and extenders. Nitric acid (10 %) 3
This mixture has excellent abrasion resistance and can be applied Phosphoric acid (5%) 1
very easily. Phosphoric acid (20 %) 3
Features Bases and bleaches
• The completely hardened Ceram C1 coating has a glossy finish, no Sodium hydroxide (10%) 1
pores and is easy to clean, mechanically very resistant, abrasion- Sodium hydroxide (50 %) 1
proof and has excellent adhesive properties. Ammonia (5%) 2
• Ceram C1 hardens without shrinking and is resistant to a large
number of chemicals, oils, greases, solvents, diluted organic and inor- Ammonium hydroxide (28 %) 1
ganic acids and bases and saline solutions. Potassium hydroxide (10%) 1
• Ceram C1 reduces friction and improves flow and efficiency. Potassium hydroxide (50 %) 1
• Excellent corrosion protection. Fixing salt (6%) 1
Soap solution (5%) 1
Technical data
Cement mortar / concrete 1
Hardness Buchholz 115 Other compounds
Density / mixture ASTM D 792 1.4 g/cm3 Isopropanol 1
Shrinkage during hardening ASTM D 2566 0.002 mm/cm Kerosene 1
Tensile shear resistance ASTM D 1002 13.8 N/mm2 Naphtha 1
Tensile strength / ultimate ASTM D 638 26.2 N/mm2 Salt water 1
strain Drainage and sewage 1
Compressive strength ASTM D 695 60 N/mm2 Toluene 1
Bending strength ASTM D 790 55.2 N/mm2 Xylene 1
Adhesive strength / steel ISO 4624 13.8 N/mm2 Bunker C 1
Impact resistance / strength ASTM D 256 11 J/m Diesel oil 1
Longitudinal expansion ASTM D 696 34.5 x 10-61 1/K
Tested at 20 °C. Sample hardened for 12 days at 20 °C. Longer hard-
coefficient
ening improves the chemical resistance.
Electrical resistance ASTM D 257 8 Ohm cm Key: 1 = resistant; 2 = short-term resistant; 3 = overflow resistant,
Thermal conductivity ASTM C 177 0.7 W/m x K immediate cleaning; 4 = not recommended for direct contact
Porosity test Test voltage 5 V/rm layer
thickness
Temperature resistance, dry ASTM D 648 140 °C
Temperature resistance, wet ASTM D 648 60 °C
Consulting guide

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 379
Consulting guide

Ceram coating

Ceram C2 - Technical data Resistance table


Description
Ceram C2 is a high-performance composite material for repairing and Fluid Factor
protecting all metal surfaces which are subject to abrasion, corrosion, Acids
cavitation and chemical exposure. Ceram C2 is applied with a coating Sulphuric acid (10%) 1
thickness of 1.5 mm. It does not shrink and consists almost entirely of
solids. Ceram C2 contains a high percentage of carbides for use under Sulphuric acid (20 %) 2
extremely abrasive operating conditions which involve complex and Hydrochloric acid (5%) 1
expensive repair measures. The material can either be used for re- Hydrochloric acid (10 %) 2
storing abraded metal surfaces or as a preventive coating which is su- Hydrochloric acid (20 %) 3
perior to the original metal in terms of its abrasive strength. Ceram C2
can be used instead of metal applications, tiles, rubber fillers, etc. Its Acetic acid (5%) 2
thermal resistance is outstanding. Acetic acid (10 %) 4
Bases and bleaches
Composition Caustic soda (10 %) 1
Polymer/aluminium oxide composite material made of a base com-
pound and reinforcement. Caustic soda (30 %) 1
Base compound: A modified polymer consisting of two components Ammonium hydroxide (28 %) 1
with an aliphatic hardening agent. Potassium hydroxide (10%) 1
Reinforcement: a mixture (protected by proprietary rights) made up Potassium hydroxide (50 %) 1
of aluminium oxide and silicon carbide particles.
This mixture has excellent abrasion resistance and can be applied Other compounds
very easily. Isopropyl alcohol 1
Kerosene 1
Features Naphtha 1
• Excellent abrasion resistance ensures long operation and usually lasts
longer than a welded-on metal coating. Salt water 1
• Can be easily moulded to any metal surface. Drainage and sewage 1
• Its tough synthetic resin structure is resistant to temperature shocks Toluene 1
and impact. Xylene 1
• Excellent adhesion ensures reliability and prevents stripping.
• Simple application reduces work expenses and downtimes. Bunker C 1
• Withstands varying chemical operating conditions when metals fail. Diesel 1
• Practical 4:1 weight and volume mixture ratio. Tested at 20 °C. Sample hardened for 7 days at 20 °C. Longer hard-
ening improves the chemical resistance.
Technical data Key: 1 = resistant; 2 = short-term resistant; 3 = overflow resistant,
immediate cleaning; 4 = not recommended for direct contact
Hardness Shore D 90
Density ASTM D 792 1.85 g/cm2
Shrinkage during hardening ASTM D 2566 0 mm/cm
Tensile shear resistance ASTM D 1002 13.24 N/mm2
Tensile strength / ultimate ASTM D 638 27 N/mm2
strain
Compressive strength ASTM D 695 103.4 N/mm2
Bending strength ASTM D 790 69.0 N/mm2
Adhesive strength / steel ASTM C 633 ---
Impact resistance / strength ASTM D 256 3.3 J/m
Longitudinal expansion ASTM D 696 ---
coefficient
Electrical resistance ASTM D 257 ---
Thermal conductivity ASTM C 177 ---
Dielectric strength ASTM D 149 4 kV/mm
Temperature resistance, dry ASTM D 648 250 °C
Temperature resistance, wet ASTM D 648 80 °C

380 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
Consulting guide

Ceram coating

Ceram C3 - Technical data Resistance table


Description
Ceram C3 is a high-performance composite material for repairing and Fluid Factor
protecting all metal surfaces which are subject to abrasion, corrosion, Acids
cavitation and chemical exposure. Ceram C3 is applied with a coating Sulphuric acid (10%) 1
thickness of 3 mm. It does not shrink and consists almost entirely of
solids. Ceram C3 contains a high percentage of carbides for use under Sulphuric acid (20 %) 2
extremely abrasive operating conditions which involve complex and Hydrochloric acid (5%) 1
expensive repair measures. The material can either be used for re- Hydrochloric acid (10 %) 2
storing abraded metal surfaces or as a preventive coating which is su- Hydrochloric acid (20 %) 3
perior to the original metal with regard to abrasive strength. Ceram
C3 can be used instead of metal applications, rubber fillers, etc. Acetic acid (5%) 2
Acetic acid (10 %) 4
Composition Bases and bleaches
Polymer/aluminium oxide composite material made of a base com- Caustic soda (10 %) 1
pound and reinforcement.
Base compound: A modified polymer consisting of two components Caustic soda (30 %) 1
with an aliphatic hardening agent. Ammonium hydroxide (28 %) 1
Reinforcement: a mixture (protected by proprietary rights) made up Potassium hydroxide (10%) 1
of aluminium oxide and silicon carbide particles. Potassium hydroxide (50 %) 1
This mixture has excellent abrasion resistance and can be applied
very easily. Other compounds
Isopropyl alcohol 1
Features Kerosene 1
• Excellent abrasion resistance ensures long operation and usually lasts Naphtha 1
longer than a welded-on metal coating.
• Its tough synthetic resin structure is resistant to temperature shocks Salt water 1
and impact. Drainage and sewage 1
• Excellent adhesion ensures reliability and prevents stripping. Toluene 1
• Simple application reduces work expenses and downtimes. Xylene 1
• Withstands varying chemical operating conditions when metals fail.
• Can be easily moulded to any metal surface. Bunker C 1
• Practical 1.7:1 weight and volume mixture ratio. Diesel 1
Tested at 20 °C. Sample hardened for 7 days at 20 °C. Longer hard-
Technical data ening improves the chemical resistance.
Key: 1 = resistant; 2 = short-term resistant; 3 = overflow resistant,
Hardness Shore D 90 immediate cleaning; 4 = not recommended for direct contact
Density ASTM D 792 1.87 g/cm3
Shrinkage during hardening ASTM D 2566 0 mm/cm
Tensile shear resistance ASTM D 1002 17 N/mm2
Tensile strength / ultimate ASTM D 638 29.7 N/mm2
strain
Compressive strength ASTM D 695 103 N/mm2
Bending strength ASTM D 790 69 N/mm2
Adhesive strength / steel ASTM C 633 15.9 N/mm2
Impact resistance / strength ASTM D 256 12 J/m
Longitudinal expansion ASTM D 696 61.8 x 10-61 1/K
coefficient
Electrical resistance ASTM D 257 8 Ohm cm
Thermal conductivity ASTM C 177 0.75 w/m x K
Dielectric strength ASTM D 149 13.4 KV/mm
Temperature resistance, dry ASTM D 648 190 °C
Temperature resistance, wet ASTM D 648 65 °C
Consulting guide

Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice 381
Consulting guide

Ceram coating

Ceram CT - Technical data


Description
Ceram CT is a modern, solvent-free two-component coating sub-
stance with various corrosion and wear protection extenders primari-
ly used for the inner coating of hydraulic components, check valves
and valves for industrial water and potable water supply.
Ceram CT is ideally suited for the corrosion protection of bronze,
steel and stainless steel surfaces exposed directly to fluids.

Composition
Solvent-free epoxy resin with polyamine hardener and various ex-
tenders. This mixture has excellent abrasion resistance and can be
applied very easily.

Features
• Visco-plastic, mechanically resistant, and resistant to abrasion and
impact.
• Excellent adhesion on bronze, steel, stainless steel and mineral sur-
faces.
• Particularly efficient in processing, since the coating is applied direct-
ly in one operation using the airless spraying method.
• Complies with the KTW recommendations and the UBA guideline for
epoxy resin in contact with potable water.
• Complies with the EU Resolution AP (2001) 1 (for potable water and
foodstuffs).
• Certified in accordance with DVGW worksheet W 270 (reproduction
of micro-organisms in potable water).

Resistance
Ceram CT has a very high resistance when pumping industrial water
and potable water with a maximum sand content of 50 g/l and a max-
imum fluid temperature of 40 °C.

Technical data

Hardness Shore D 90
Density, liquid ASTM D 792 1.25 g/cm3
Adhesive strength / steel DIN EN ISO >12 Mpa
4624:2003
Solid content (mixture), vol- 100 % or
ume 740 ml/kg
Solid content (mixture), 100 %
weight
Porosity test DIN 55670 5 V/rm layer thick-
ness

382 Wilo water management catalogue – 50 Hz – Drainage and sewage – Wastewater transport and dewatering – edition 2014/2015 – Subject to change without prior notice
$OZD\VDFOHDQVROXWLRQ
(FRQRPLFDODQGVWXUG\

ZZZZLORFRP

7KH*HUPDQ:DWHU3DUWQHUVKLS
LVDSODWIRUPWKDWFRRUGLQDWHV
DFWLYLWLHVLQWKHÀHOGRIZDWHU
PDQDJHPHQWSURPRWHV
LQQRYDWLRQDQGSRROV
LQIRUPDWLRQ

:LOR5H[D352
:LOR
R5
55H[D
H[
[D 35
352
352 :LOR(08)$
:LOOR(0
R (08
R( 08 )$ :LOR(08)76
:LOR (08 )76
2149862/500/1405/EN/MP

WILO SE
Nortkirchenstraße 100
D-44263 Dortmund
Germany
T +49 231 4102-0
F +49 231 4102-7363
wilo@wilo.com
www.wilo.com

Pioneering for You More contact details at www.wilo.com

You might also like