You are on page 1of 23

SPECIFIC PLAN

PRELIMINARY SITE PLAN APPLICATION

NORTH EDGEHILL COMMONS


2021SP-023-001

M AY 1 7 , 2 0 2 1
2 0 2 1 SP-0 2 3 -0 0 1

DEVELOPMENT SUMMARY
S U MM ARY • Entrepreneurial Incubator – Anchoring and complementing the outdoor green, the indoor CIVIL

• COUNCIL DISTRICT: 19, FREDDIE O’CONNELL mixed use/retail portion of the Commons creates an all-weather gathering place, and focus
• Site layout, utilities, access, and grading will be provided at final site plan. The proposed
• OWNER(S) OF RECORD: LEE A. BEAMAN, BEAMAN MOTOR COMPANY, for both collaborative workspaces, retail and food startups in small, flexible spaces. Shared
development will utilize existing infrastructure surrounding the site. If additional
1525 BROADWAY NASHVILLE, TN 37203, 888.423.2626 dining and meeting spaces provide “third places” for informal gathering within a grand
improvements are required, they will be incorporated at final site plan.
• SP NAME: NORTH EDGEHILL COMMONS hall.
• All existing information shown is provided from readily available GIS information and is not
• SP NUMBER: 2021SP-023-001 • Streetscapes – The intricately designed streetscapes feature 2 story facades at the base
considered to be accurate or complete.
• PLAN PREPARATION DATE: 05/17/21 of each block inspired by long gone historic commercial architecture of the Edgehill
• Any excavation, fill, or disturbance of the existing ground elevation must be done in
• APPLICANT: TUCK HINTON ARCHITECTURE & DESIGN, CURTIS LESH, 615.254.4100, neighborhood, narrow brick / cobblestone streets, widened sidewalks, lush street trees,
accordance with storm water management ordinance NO. 78/840 and approved by the
clesh@tuckhinton.com and parallel/angled parking. The organic pedestrian scaled grid features an average block
Metropolitan Development of Water Services.
• ARCHITECT: TUCK HINTON ARCHITECTURE & DESIGN, CURTIS LESH, 615.254.4100, size similar to Savannah’s famously intimate blocks and are designed to facilitate active
• The final lot count and details of the plans shall be governed by the appropriate stormwater
clesh@tuckhinton.com “outdoor rooms” and walkability.
regulation at the time of final application.
• CIVIL ENGINEER: KIMLEY HORN & ASSOCIATES, INC., MARY MCGOWAN, 615.800.4004, • Edgehill Commons – The heart of the district is a significant contribution to the public
• Metro Water Services shall be provided sufficient and unencumbered access in order to
mary.mcgowan@kimley-horn.com realm of the neighborhood. This urbane “green” will become a key gathering place inviting
maintain and repair utilities in the site.
• MASTER PLANNING/ DESIGN/ SPATIAL STORY TELLING: STORYLAND STUDIOS neighbors to gather under the canopy of mature trees by day and stars at night. A key feature
• Size driveway culverts per the design criteria set forth by the Metro Stormwater Management
• US FEMA FIRM: 47037C0243H DATED 04/05/2017 is the W.E. “Quarry” playground, integrating large slabs of limestone for kids to climb on
Manual (minimum driveway culvert in Metro Row is 15” CMP)
• LOT 1 RE-SUB LOTS 1-2-3-4 EDGEHILL ESTATES SEC 117 and scramble over, honoring artist William Edmondson and the history of neighborhood
• The project is located in flood zone X “UNSHADED” per FEMA Map 47037C0243H dated
workers who would drop off leftover pieces of limestone for him to transform into pieces of
4/5/2017.
sculptural art.
• The current layout depicts the use of underground stormwater detention and the use of
• Art / History Walk – The adjacent regional trail and on-site sidewalks will be “curated” as an
proprietary water quality units. The proprietary water quality units will require a low impact
outdoor art/history museum highlighting the story of the historic Edgehill neighborhood
development waiver. If a LID waiver is not obtained, then the proposed development will
P U R P OS E and its contributions to culture. The pedestrian “Aurora Alley” features an overhead canopy
provide LID following the stormwater manual.
North Edgehill Commons is proposed as a sustainable live/work/play district at the northern of LED string lights that highlight a theme of colorful diversity and inclusion.

edge of the historic Edgehill neighborhood. Based on its strategic gateway and edge location • Regional Trail – Accessed from five points on the site, the northern regional trail will form

at the intersection of the central north/south spine of Edgehill (12th Avenue S) and the northern a key interpretive spine of the pedestrian circulation of the site, telling the highlights of the

boundary of the neighborhood (I-40), the site provides a unique opportunity to re-establish a Edgehill story to all those traversing the site.

strong sense of place, identity, edge, and arrival from downtown to this special walkable, urbane
neighborhood. The district is designed to follow the intent of the urban to rural “Transect” model,
by providing a density transition from the high-rise Gulch district to the mid / low-rise Edgehill
neighborhood. This re-imagining of a former suburban scaled automotive services facility, and
surface parking in an Industrial Zone will provide significant contributions to the public realm via
several new community amenities, based on input by existing residents:

• 12th Avenue Connection – The existing 12th Avenue bridge sidewalk is proposed to be
enhanced by a raised boardwalk which would combine the width of the bike lane, and the
existing sidewalk into a “High-Line” type pedestrian experience.
• District Entry Statement – The 12th Avenue District pedestrian entry to both the regional trail,
and the project would be marked by a vertical District Entry Statement which clearly identifies
the Edgehill neighborhood as distinct from the Gulch and downtown Nashville.
• Community Hall – The program allows for a rooftop community hall, and amenity deck
overlooking the Commons, for residents and neighborhood associations on a first come, first
served basis.
2 0 2 1 SP-0 2 3 -0 0 1

DEVELOPMENT SITE DATA TABLE •



ACREAGE: 6.79 ACRES (5.986+.8019)
MIXED USE: 5.1 ACRES
OPEN: 1.55 ACRES
ROW DEDICATION: 0.14 ACRES
• DENSITY
DWELLING UNITS: 600 UNITS TOTAL
HOTEL ROOMS: 200 KEYS TOTAL
OFFICE: 160,000 RENTABLE SQUARE FEET TOTAL
COMMERCIAL/ RETAIL: 35,000 RENTABLE SQUARE FEET TOTAL
• FAR: 3.0 MAX WITH SPECIAL PROVISIONS 17.12.070 A-F AT PUBLIC AND INTERNAL STREETS
2.98 PROVIDED
• IMPERVIOUS SURFACE RATIO: 0.9 MAX
0.80 PROVIDED
• PARKING: PROVIDED PARKING SHALL MEET THE REQUIREMENTS OF THE PARKING
STANDARDS OF THE ZONING CODE (17.20) FOR UZO. BICYCLE PARKING SHALL BE PROVIDED
PER METRO STANDARDS.
• USES: PER MUG-A ZONING
PROHIBITED: ALTERNATIVE FINANCIAL SERVICES, AUTO REPAIR, AUTO SALES, GAS
STATION, SHORT TERM RENTAL PROPERTY (STRP) - NOT OWNER OCCUPIED
• MAXIMUM HEIGHT
STRUCTURE A : 10 STORIES IN 133’
STRUCTURE B: 8 STORIES IN 107’
STRUCTURE C: 5 STORIES IN 68’
STRUCTURE D: 7 STORIES IN 94’
• MINIMUM FIRST FLOOR HEIGHT (MEASURED FROM FINISH FLOOR TO FINISH FLOOR) 16’
• BUILD-TO (PERCENTAGE OF THE FRONT FACADE BUILT TO PUBLIC SIDEWALK OR OPEN
SPACE) 80% WITHIN 5’
• SIDE SETBACK 0’
• REAR SETBACK 20’- ASSUMED AT EAST EDGE OF SITE
• GLAZING (% OF FACADE MEASURED FROM FINISHED FLOORS TO FINISH FLOOR ALONG
PUBLIC STREETS AND OPEN SPACES)
RESIDENTIAL 25% MINIMUM
COMMERCIAL 50% GROUND FLOORS, 30% UPPER FLOORS
• FEDERAL COMPLIANCE
ALL DEVELOPMENT WITHIN THE BOUNDARIES OF THIS PLAN WILL MEET THE
REQUIREMENTS OF THE AMERICANS WITH DISABILITIES ACT AND THE FAIR HOUSING
ACT
• GROUND FLOOR ACCESS: NON-RESIDENTIAL GROUND FLOOR USES SHALL PROVIDE A
PUBLIC ENTRANCE FROM THE PUBLIC SIDEWALK
• BUILDING FRONTAGE/ORIENTATION: ALL STRUCTURES SHALL PROVIDE A PRIMARY
FRONTAGE ON TO STREETS AND/OR OPEN SPACE AS WELL AS PROVIDE A MINIMUM OF
ONE PRINCIPAL ENTRANCE ON TO PUBLIC RIGHT OF WAY AND/OR OPEN SPACE.
• PARKING GARAGE SCREENING/LINING: PARKING STRUCTURES FRONTING A PUBLIC STREET
R.O.W. OR PUBLIC OPEN SPACE SHALL BE SCREENED AND LINED WITH AN ACTIVE USE
ALONG THE GROUND FLOOR.
• FALL-BACK ZONING MUG-A
• LANDSCAPING AND TREE DENSITY REQUIREMENTS PER 2021SP-023-001
2 0 2 1 SP-0 2 3 -0 0 1

SITE PLAN
The final site plan/ building permit site plan shall depict the required public sidewalks, any required grass strip or frontage zone and the location of all
existing and proposed vertical obstructions within the required sidewalk and grass strip or frontage zone. Prior to the issuance of use and occupancy
permits, existing vertical obstructions shall be relocated outside of the required sidewalk. Vertical obstructions are only permitted within the required
grass strip or frontage zone.

• Loading/unloading for waste/recycle disposal is internal(garages).


• Any excavation, fill, or disturbance of the existing ground elevation must be done in accordance with storm water management ordinance No. 78/840
and approved by The Metropolitan Department of Water Services.
• Drawing indicates basic premise of the development, as it pertains to Stormwater approval / comments only. The final lot count and details of the
plan shall be governed by the appropriate stormwater regulations at the time of final application.
• Metro Water Services shall be provided sufficient and unencumbered access in order to maintain and repair utilities in this site.
• Size driveway culverts per the design criteria set forth by the Metro Stormwater Management Manual (Minimum driveway culvert in Metro ROW
is 15’ CMP).

A
10 STORIES IN 133’

B
8 STORIES IN 107’

6 STORIES IN 81’

C
D 7 STORIES IN 94’

5 STORIES IN 68’
2 0 2 1 SP-0 2 3 -0 0 1

VIEW OF COMMONS
2 0 2 1 SP-0 2 3 -0 0 1

VIEW OF COMMUNITY HALL


2 0 2 1 SP-0 2 3 -0 0 1

VIEW OF COMMUNITY HALL


2 0 2 1 SP-0 2 3 -0 0 1

AERIAL PERSPECTIVE
2 0 2 1 SP-0 2 3 -0 0 1

BIRD’S EYE VIEW


2 0 2 1 SP-0 2 3 -0 0 1

PRECEDENTS

WALKABLE/ DIVERSE/ HISTORIC/ PEACEFUL/ NEIGHBORLY WALKABLE/ DIVERSE/ HISTORIC/ PEACEFUL/ NEIGHBORLY
WALKABLE // DIVERSE // HISTORIC // PEACEFUL // NEIGHBORLY
WALKABILITY

WALKABLE/ DIVERSE/ HISTORIC/ PEACEFUL/ NEIGHBORLY 12TH AVENUE CONNECTION


ENTREPRENEURIAL INCUBATOR 12th STREET CONNECTION
2 0 2 1 SP-0 2 3 -0 0 1

PRECEDENTS

HEALTHY FOOD HEALTHY FOOD VIEWS FROM ROSE PARK

VIEWS (North from Rose Park)

GREENSPACE
May 17, 2021

Metro Planning Department

RE: Traffic Study for North Edge Development

The proposed development has conducted an initial traffic impact study based on discussions with
Metro Public Works Department. At this time, the scope of the study is being revised to reflect
updated projected traffic counts. The attached trip generation is provided for reference during the
initial SP review while the study area is solidified with Public Works.

Please contact me at 615.800.4004 or mary.mcgowan@kimley-horn.com should you have any


questions.

Sincerely,

Mary McGowan, P.E.

kimley-horn.com 214 Oceanside Drive, Nashville, TN 37203 615 564 2701


FORM A – INITIAL TRAFFIC STUDY SCREENING EVALUATION
Nashville-Davidson County Traffic Study Screening
Submit this form to the Metro Public Works Department in advance of requesting a Pre-Study Scope Determination Conference.
Its purpose is to help determine the need for a traffic study, and if so, the type of study to be conducted. The Metro Public
Works Department will notify the applicant if a conference needs to be scheduled.
Date 3/4/2021 Codes or Planning Case No:
Submitted:
Metro Public Works Department Contact Numbers
Metro Public Works – Traffic and Parking Section (615) 862-8760 (615) 880-2012(f)
Project Name and
Hawkins Street Mixed Use
Location (specific):
Nearest Major Cross Streets
12th Avenue South (Arterial-Boulevard), South Street (Collector-Avenue)
and Functional Classification:
Applicant or
Marquette Companies Phone: 630-420-4730
Project Developer:
Traffic Study Preparer: Kimley Horn Phone: 615-800-4026

Has a study been prepared for this Yes Date: Title/Case No:
location within the past 5-years? X No
Include the Following Materials with this Form (Unless this is a Rezoning)
Two sets of site plans showing all existing and proposed structures, parking and loading areas,
driveways, sidewalks and bike paths/lanes, and on/off site circulation.
Screening Rezoning Analysis Traffic Access Study Traffic Impact Statement Traffic Impact Analysis
Thresholds (250/pkhr) (50-99/pkhr) (100-249/pkhr) (250+/pkhr)
Please complete Prior to Meeting
Trip Generation Calculation
Zoning District Land Use Project Size
(List Each District) (List Each Use)
Peak Hour Trips
(Square Feet or Daily Trips
Use Additional Use Additional
Dwelling Units) AM PM
Sheet if Necessary Sheet if Necessary

Existing
IWD See attached spreadsheet

Total

Proposed
SP See attached spreadsheet

Total
Net Increase/Decrease (+ or -)
Above/Below Existing Trips

Metro Reviewer
Comments:

Recommended Traffic Study Type None Traffic Impact Traffic Impact


Rezoning Analysis Traffic Access Study
(circle one) (Issue Form B) Statement Analysis

Evaluated by: Phone:


Metro Reviewer (Print)

Signature: Date:
Trip Generation - Hawkins Street-Existing Auto Center

ITE AM Peak Hour PM Peak Hour


Land Use Setting/Location Density Daily
Code Total Enter Exit Total Enter Exit

942 Automobile Care Center General Urban/Suburban 39,000 s.f. - 88 58 30 106 51 55

GROSS TRIPS 0 88 58 30 106 51 55


Trip Generation - PROJECT NAME

ITE AM Peak Hour PM Peak Hour


Land Use Setting/Location Density Daily
Code Total Enter Exit Total Enter Exit

222 Multifamily Housing (High-Rise) General Urban/Suburban 550 d.u. 2,379 167 40 127 195 119 76
310 Hotel General Urban/Suburban 200 rooms 1,831 95 56 39 124 63 61
710 General Office Building General Urban/Suburban 160,000 s.f. 1,674 177 152 25 177 28 149
820 Shopping Center (Average Rate) General Urban/Suburban 35,000 s.f. 1,321 33 20 13 133 64 69

GROSS TRIPS 7,205 472 268 204 629 274 355

Gross Trips - Before Reductions 7,205 472 268 204 629 274 355
Residential 2,379 167 40 127 195 119 76
Hotel 1,831 95 56 39 124 63 61
Office 1,674 177 152 25 177 28 149
Retail 1,321 33 20 13 133 64 69
Restaurant 0 0 0 0 0 0 0
Other 0 0 0 0 0 0 0

Reduction - Internal Capture -1,144 -42 -21 -21 -84 -42 -42
Residential -288 -5 -1 -4 -32 -21 -11
Hotel -68 -6 0 -6 -6 -5 -1
Office -296 -18 -12 -6 -12 -4 -8
Retail -492 -13 -8 -5 -34 -12 -22
Restaurant 0 0 0 0 0 0 0

Reduction - Pass-By AM PM -282 -6 -3 -3 -34 -17 -17


820 Shopping Center General Urban/Suburban 34% 34% -282 -6 -3 -3 -34 -17 -17

NEW TRIPS 5,779 424 244 180 511 215 296


ALTERNATIVE 1
ALTERNATIVE 2

DRIVEWAY VOLUMES 6,061 430 247 183 545 232 313


ALTERNATIVE 1
ALTERNATIVE 2
WATER & SEWER SERVICE PERMIT
Thursday, April 1, 2021 12:13 pm Page 1 of 2

DATE ENTERED PERMIT TYPE / NUMBER REFERENCE PROJECT NUMBER


1-Apr-2021 SEWERCAP T2021019610 WATERCAP T20210196 67S18(3A)
PARCEL
ADDRESS: 1000 HAWKINS ST NASHVILLE, TN 37203 APN: 09313055700
PERMIT NAME: HAWKINS AND 12TH AVENUE DISTRICT: 19
OTHER LOCATION: 1000 HAWKINS ST 37203
PROPOSED DEVELOPMENT
WSSCAP WS Sewer Capacity Fees
EASEMENT NUMBER:
EXCAVATION NUMBER:

Proposed: 378 One-BR Units (94,500), 108 Two-BR Units (32,400), 54 Three-BR Units (18,900), 160,000 Sq. Ft. Office Space (16,000), 130
Room Hotel (65,000), 25,000 Sq. Ft. Restaurant (50,000), 25,000 Sq. Ft. Retail Space (3,750) = 280,500 GPD
Existing: 40,00 Sq. Ft. Warehouse (1,000 GPD)
Projected Flow: 279,550 GPD

Commitment:
1 Year (30%): $552,000.00 (Due 6/30/2021)
2 Year (55%): $1,012,000.00 (Due 4/1/2022)
Perpetuity (100%): $1,837,700.00 (Due 4/1/2023)

Private Sewer Connections to Existing 12-inch public sewer main crossing the site | Maintaining separate storm and sanitary sewer
will also be required within the Demonbreun basin.

~~Notes~~
* Thirty percent (30%) is due within 90 days from the permit date.
* Three 90 day extensions are all allowed. Extensions do not affect the permit date or the final payment date.
* Regardless of utilization of extensions, fifty- five (55%) of the capacity fee is due by the one year anniversary of the permit date.
* One hundred (100%) is due two (2) years from the permit date.
* Capacity fees paid are non-refundable with the exception of projects that are not approved by other Metro agencies. Refunds may be
requested following current Metro Government Code.
* All applicable tap fees, service charges, and any remaining capacity fees must be paid at the time of application for physical
connection to the public system or final U&O approval.
* sewer facilities will be at the expense of the developer. This includes any required offsite public infrastructure improvements unless
there is a Developer/Metro Participation Agreement approved by MWS and Metro Council and recorded by Metro Clerk.
* Any capacity installment payments outside allowable schedules will result in a relinquishment of remaining capacity. Request of any
capacity above that that has been secured by capacity charge payment will require reapplication, system capacity review, and
application fee.
* Availability of water service is only representative of that for the domestic flow volume(s) requested. Needed volume above that
submitted to Metro Water Services, such as fire flows, will require submittal and approval by the Metro Fire Department.

If you have any questions please email MWS.EPlanRev@nashville.gov.

OWNER OF RECORD
BEAMAN MOTOR COMPANY PHONE:
1525 BROADWAY
NASHVILLE, TN 37203

PROFESSIONAL
PHONE:
2
!!P!! D C̀
"

(
!! !

(
!
P
!

09313058000
(
! 093130L90000CO
!
P
09314000500
D(
480

(
50 09313010500 47

492
0
!
P 093130L00300CO093090B90000CO
Hawkins and 12th Avenue
179!
P09313057900 188 2
2
09313008300
! 180 093130L00200CO
093130C12500CO093130L90100CO 259
!
09313008200 018 214 ! 093090B00500CO

476
P 261,650 GPD
I40 09313012300 008 4
093130C12400CO D P 76

(
! !
P ! (
!

(
P !! (
! 093130C13000CO 009

(
! !
D 2 464

464
E !
P P! !!
093130C16300CO
! !D ( !!
P 460
P !
P (D 260 261
09313010300 09313010400 182
!
P
093130C80100CO

((
! !

49
P D
!!
032 09314000600 (
010
I40
! 147 093130C37800CO 96 4 015 !
P !
P
0931405610009314056300
P !
P

6
09313006800 011
D !
P
019 !
P (
!

48 I40 R
!
P
09314002800
012 W 148 093130C90000CO
!
P !
P
D 09314056200 09314055500

8
( !
! P
093130C23400CO
!
P 016 017 269 135
2 09313012500 022 136
! DIVISIO 093130C05500CO 023 P270 !
!
!
P !
P !
N ST

48
P
500 09313012400 09314003500(
!
P !
AM
D 09313054800 093130C11100CO
P ! D !

0
(
! !
P ! P

0
P
09314002900
056 P 49 ! 09314056500

48
09314003600
!
2
18" 234FB014 P
162D 093130C80100CO 146 2 !
( 093132A90000CO
!!
09314055700
!
P
P190
!
P Pk!! P093130C80100CO
I4 029 !

(
!
09313058400 203 0 028
k
093132A00100CO 09314003300
D ! 1 09314056400 271
!
P(
027 !
P (
! D 8
R 093130D01900CO "
!
P !
P !
054
P
141 201!202 A 09313020500
!
P !
P 093132A01100CO
!
M
P !
P P
053
P 059
!
P D093130D00100CO 026
!
P 262

468
!
P!P (
! P145 2 09314057300
P058! ! D
!
P! ! (
!
093130D90300CO
!
093130I90000CO
P!P! P 50
!
P025 ! P D(
!
263 09314004000 P 264
!
093130D90200CO

8"
093132B01100CO 0 96
!
P !
P
4 D D k D

(
(
! !
D (

(
k !
k 093130D90100CO 09314057200 !

((
09313022100 093132B90000CO
(! k
k! k
! 293 !
k P
292
(
! !
!
18014
P
093132B00700CO 093130D00300CO 50 09313054300
093130P90000CO 093130D05900CO 4 093130D90000CO 09314056600
09314012100
!
P
!
P064 093132B00500CO 09314056700 291 09314057100
P266
!
206 207 067 50 1
S
City Low
066
!
P!P 4 (
!D
D
!
k
P
k
( 8" 09314012300
D
(! !
P! 12TH AVE
033 290
093134P90000CO093134S90000CO 50 06784
P ! P ! P
D 8 034 09314012400
( 4
!
093130T90000CO 92 496
073 222 !
P 09314012600
09313027200093130Q00200CO !
P !
P
287
!
P
093130Q90000CO 093134S00400CO 165 218 223 09314056800
!
P
036
484
071!
!
P 166 !
P P 6"
! !
P!P
P093130T01100CO
!
P !
P
D 081 496 289 D(
!
( P082 083
" "(

!!
09313054200
k k 09314057000
09313030100
(

k!
040 039038
P!
093130T01200CO 128 080
) 8 8

!
P
09313030300
!
P
! !
2
! 4 80 484 !
P!
P
084
P
09313030200 093130S90000CO !
!
P
53
P Sewer

"
093130T90100CO I65 N

15
!
P
A

093130T01600CO ! 09313029700
D 092
8(6

( !
P (
! D 5 00

6A
103!P 104! P 127! 216 077
2
! 076 k !
P 492
S1

00
P!
P
093130O00100CO093134B00100CO
!
P 488
6(7

S0
!k Water
09313035200093134Q00100CO (! D 098 041 042
2
!

70
09313035800093134B00300CO 09313055700
!
!
P !
04
! P !
P !
09313055000
P
086
093134Q90000CO !
P 085
(
! D P 043 I65 S 5
!
P ! 122 093134B90000CO !
P !
P 157 044 496
53
P!
P !
123 P!P124 ! P 536
!
P
045 500
P!
! P
047
126 ! HAWK 09314059000 !
P
087
D
( INS ST !
P 048
8" 76W D
(
! !
P
09313037300 !
P 548
P091 !
! P096 C 0 22A
D 050 10501060900
! 095 147
(D
(
!
P 36" 59W P !
! P 105021Q22000CO 002 00910502003100
00010 031
! !
P( D
!
P051 D 540 105021Q00100CO
!
P
! P(
! !
S OUTH S 10501061100 !
P
P049
! T (
! D 10502050800 10502051000
Waverly Belmont D
642
10501008600 P030
!
007 105021Q90000CO
009 520 P10502002000
!
P !
P P006
1050100850010501008900 005
! (
! !

(
!!

(
10501008400
!
P !
P 004 5 105021Q91800CO 10502001900
!
P !
P 32 105012F90000CO (D
!
052 105010T90000CO P !
! P 520 ! 6"( 015
003 002 P 005! D
10501009000 P516 008
!
!
P 10501050500 004 P007 512 !
P
! 10501007800 10501049400 105020J90000CO ! 016 (
D
(
029 105011P90000CO10502047600 !
!
P P006 !
P! P010 D !
04610501009300 ! 10502046900 105020P90000CO !
P
!175
P 015 105012K90000CO 528 403 10502046800 011
D ALY
10501051100 105021I90000CO
10501009400
(
8
!
P 524
105013P00100CO !
P " 014 105020Q90000CO
P 10502009600
!
10501055100 105012V90000CO
(D
! 105020C90000CO
105012U90000CO 10501052100105012A90000CO (D
! !
P 105010X90000CO
!
P 011 149 1050204840010502048700 (
D
(!
!
P
10501055200 105013P90000CO !
P 105021J90000CO
!D
10502048900 10502046400
!
P
10501051800105010S90000CO 105012J90000CO !
P
10502009800
!
P!P (
! D !
P
P 10501055300
! !
P 10501052000 105012E90000CO 148105021L90000CO105021G90000CO
!
P
105010Y90000CO
568

!
P
105012T90000CO 10501052500 1050205040010502050200 10502049600105021F90000CO
D
( !
P ! P
105012Z90000CO
!
!
P 576 10502009900
105011Q90000CO 105012S90000CO 5 7 2 55 2 105020F90000CO
1050105740010502051300 548 544
5 105020B90000CO
!
P
105012W90000CO 10501052700105013O90000CO 5 6
P10501052800 10501053200 5105012Q90000CO !
! 016 10501062500
564 560 10502051700
105010L90000CO 84 P 10502010000
!
P ! !
P
! 105011S90000CO10501053500 10501053700 10501062400 10502052600 104
P 025
( D 105012D90000CO 1050205140010502051600105020E90000CO Legend
105010P90000CO 024 105013J90000CO 10501053900
!
P
!
P !
P !P 88
5 596
P151 032!
! P 105020S90000CO
D
Sewer
! Manholes
( 10502010300
019 105014B90000CO ! 10501062300
!
P !
P
10501055000 168 ! !
P
105014A00700CO
P
105023D90000CO
!
P D !
P!
5 105021P90000CO
P
7
(
105012R90000CO !
P sanForceMain
!
P 6
041105014A03100CO105014A90000CO
!
P D !
P
021 10502052400 105020W90000CO Sewer Gravity Main
!
P (! !
P
!
P !
P 105014A03200CO !
P ! P017 !
027105014A02900CO 105014A03300CO 105014A90100CO
P! P D 10502052100 10502045700 !
P
10502052800
(
!
P ! !
P !
153 !
P watMain 10502044000
P 10501048900 417 ALY 105014A04200CO 10501047100 105020W00200CO10502052000
6"

P
10501032500 P!
! ! P
10501049500 105023A90000CO
10502049000Property
!
P
with LIS
592

105014A04500CO612 0 4
6 10502050600
53 ! ! Contour Elevation Lines (4 ft)
P032 608 022 ( D 10502044400
632 624 105023B90000CO
Streams
580

616 !
P !
P
033
! 034
D P029

Ë
(
1" 061F 10502045300
!
628
10501030900
!
P !
P! P B 032 628 030 105023C00100CO10502044500
P039
! 592 632 105023C90000CO
620 624

037 036 Rose


!
P
600 10501049100 105023E90000CO
!
P !
P ! P 035 105020A90000CO
2
! 2
!
105023F90000CO
!
1 inch = 300 feet
!
10501032300! 10501049000 !
P P 10502044900
620

031 026!
P
!
P
(
! D
(
!
REQUEST FOR WATER & SEWER AVAILABILITY
Projects that require 3,500 Gallons Per Day of flow or more must enclose a check for $600.00 made payable to Metro Water
Services for this study. Please note, this study will take approximately 15 working days to complete.

The original permit will be valid for 90 days and may be requested to be updated three times (90 additional days per update) at
no cost. The permit will be void if it has not been updated within this time frame.

Information for the Availability / Capacity Response Permit (Please Print)


Date 03/08/2021
Name of Requestor Mary McGowan
Company Name (if applicable) Kimley-Horn
Address 214 Oceanside Drive
City, State, Zip Code Nashville, TN 37204
Phone Number 615-800-4004
E-Mail Address mary.mcgowan@kimley-horn.com

PLEASE NOTE THAT A SITE UTILITY PLAN AND/OR


SUBDIVISION PLAT MUST BE PROVIDED TO
PROCESS THE REQUEST

Requested Property Information (Please Print)


Development Name Hawkins and 12th Avenue

Address of Property
Map and Parcel(s) 09313055700 and 09314059000

Existing Use of Property w/ Flow (in G.P. D.) Car Dealership/ Body Shop

Purpose of Construction / Intended Use / # of Lots Mixed Use Development - 500 Key Hotel; 540 Apartment

Units: 378 - 1 bedroom, 108 - 2 bedroom, 54 - 3 bedroom;160,000 SF Office Space; 50,000 SF Commercial Space

Development Acreage / Subdivision # 6.79 Acres

Square Footage of Existing Building 40,000 sq. ft

Projected Flow (in G.P.D.) 279,550 G.P.D.

Please address all correspondence to: Metro Water Services - Development Section
1st floor of the Metro Office Building
800 Second Avenue South - P.O. Box 196300
Nashville, TN 37219-6300

Phone Number: (615)862-7225 or Email: MWS.EplanRev@nashville.gov

This is given as an aid for the public in requesting a permit of availability for water and/or sewer for property served by Metro Water Services.

Date Received Check # Received by Site Plan


WATER AND SANITARY SEWER ESTIMATED DEMAND
AND PIPE CAPACITY
Per Metro Nashville

PREPARED FOR: Metro Water Services PREPARED BY: Mary McGowan DATE: 3/8/2021
DESCRIPTION: Mixed Use REVISED BY: DATE:
ADDRESS: 1000 Hawkins St. REVISED BY: DATE:
Nashville, TN REVISED BY: DATE:
KH PROJECT #: 118389000 LEGEND
User Input
Calculated
Note to User: The majority of the Estimated Demand Rates used below are from Nashville Metro Water Services Guide to New Construction, Appendix 3 - "Projected Flow
Examples." This list has been supplemented with additional rates according to various resources. Supplemental rates that have been added are indented and italicized. Calculation
assumptions have been noted in cell comments.
ESTIMATED DEMAND
# of Units Unit Flow Total Flow (gpd)
Discharge Facility Design Unit
Existing Proposed (gpd) Existing Proposed
Single Family Dwelling Per Dwelling 350
Multi-Family Housing (3 BR) Per Dwelling 54 350 18,900
Multi-Family Housing (2 BR) Per Dwelling 108 300 32,400
Multi-Family Housing (1 BR) Per Dwelling 378 200 250 75,600 94,500
General Office Space Per Employee 25
General Office Space Per SF 160,000 0.1 16,000
Office / Warehouse Space Per SF 0.1
Warehouse Distribution Per SF 40,000 0.025 1,000
Warehouse Self-Storage Per Storage Unit 0.2
Schools w/ Showers & Cafeteria Per Person 16
Schools w/o Showers & Cafeteria Per Person 12
Boarding Schools / Dormitories Per Person 75
Motels at 65 Gal/Person (rooms only) Per Person 130
Hotel Per Room 500 130 65,000
Trailer Courts at 3 person/trailer Per Trailer 225
Restaurants Per Seat 40
Restaurants (Full Service) Per SF 25,000 2.0 50,000
Restaurants (Counter Service or Fine Dining) Per SF 1.3
Restaurants (Fast Food) Per SF 2.2
Service Station Per Fuel Island 1000
Factories Per Person Per 8HR Shift 25
Shopping Centers (no food) Per SF 0.15
Retail Per SF 25,000 0.15 3,750
Hospitals Per Bed 200
Nursing Homes (+ 75 gallons for laundry) Per Bed 120
Child Care Center Per child and Adult 10
Laundromats Per Machine 250
Swimming Pools Per Swimmer 10
Theaters, Auditorium Type Per Seat 5
Retirement Living Per Resident 100
Church (With Kitchen) Per Seat 5
Car Wash (Stand alone) Per Bay 500
Barber/Salon Per Station 200

Total Estimated Demand (gpd) 1,000 261,650 280,500


Existing Proposed

ESTIMATED CAPACITY FEES

Difference In Demand: 260,650 gpd INCREASE Water and Sewer Capacity Study Fee Required?* YES $ 600.00
Water Capacity Fee $1375 / Unit** $ 1,027,950.00

*Metro Nashville - Capacity Study Fee ($500) is required when demand increases 3,500 gpd or more. Sewer Capacity Fee $2300 / Unit** $ 1,719,450.00
**Unit = 350 GPD
Total Capacity Fees (Estimated) $ 2,747,400.00

Page 1
S
068 543.0
0
#915
566.00 ¯
#909 567.00 Not to Scale

12TH AVE
#901 Date: 3/8/2021
222 073 568.00

ES
#805

166 165 218 - - - CAUTION - - -


THE POSITION OF THE
223 WATER AND SANITARY

12T H A V
SEWER MAINS SHOWN
081 ARE APPROXIMATE AND
080 ARE INTENDED TO
542.00 082 083 SHOW THE GENERAL
LOCATIONS ONLY.
#801 093-13 THE SIZES NOTED ARE
128 TO THE BEST OF MWS
12 KNOWLEDGE. IN ALL
14 " CASES WHERE PRECISE
084 04 LOCATION AND MAIN
()2 SIZES ARE REQUIRED,
0 8 FIELD VERIFICATION
WILL BE NECESSARY.
076

67 )
092

8"
/19 8(6A
093-14

1
67
/

S
1 S1
12

VE
HA

A
WK 14 "
0

H
04
70

T
INS
"

)2
S0

ST 0
/19 06A

12
8
15
1
70
1/

12"
557.00 1404()208 041
098 042 12
#1000 "

550.00
#1201
085 140
4()2
086 08 043
044

S
157
MULTIPLE

A VE
CONNECTION POINTS 590.00
FOR DIFFERENT #920

12T H
087 091 PHASES
#825

096
031.00

HAWKIN
S ST
8"

8
967
609.00

1
67S18
(1 095 147 HAWKIN
S ST
#810

8"
1/1/19 2A) 001

67S
67

1/1/1 (6A)
002
611.00
031
#1001
E A VE

105-01
508.00
ID

030 10" #930


007 67S18(3 005 10" SOUTH S
) T
1
413 ALY

67S18(3
009 /1/1967 )
SOUTHS

006 1/1/1967 004 105-02


10" Legend
002 10
494.00
67S18(3
) " Sewer Gravity Main
3

SOUTH S
00

#1020 1/1/1967 003 67S18(3


) T In Service
1/1/196 005
7 Under Construction
505.

004
#101
543.0
0
#915
566.00

08
7
#909 567.00
¯

9
Not to Scale

6"
#901
Date: 3/8/2021
568.00

1/1/1 0
234FB0
#805

- - - CAUTION - - -
THE POSITION OF THE
17893 WATER AND SANITARY
SEWER MAINS SHOWN

S
ARE APPROXIMATE AND
542.00 ARE INTENDED TO
SHOW THE GENERAL

A VE
#801 LOCATIONS ONLY.

8"
THE SIZES NOTED ARE

H
TO THE BEST OF MWS
KNOWLEDGE. IN ALL

8"
12T
093-13 CASES WHERE PRECISE
LOCATION AND MAIN
SIZES ARE REQUIRED,
13607 FIELD VERIFICATION
WILL BE NECESSARY.

8"
093-14
8"

MULTIPLE
06726
557.00
CONNECTION POINTS
#1000 FOR DIFFERENT
PHASES

6"
09781
1 8
76 /1/1 "
W 97

S
C0 6
22
A

A VE
09782
590.00
#920

12T H
#825
031.00

8"
1/1/1976
76WC02
2A
609.00 09783 8" HAWKIN
#810 1/1/1976 S ST
76WC022
A 09784
01160
E A VE

611.00
ID

06682 #1001
508.00
#930
06681
SOUTHS

36"
1/1/1963
SOUTH S 6" Legend
T 59W0001
0 1/1/1893 6" 06680 Water Main
494.00
In Service
105-01 1/1/1893 105-02
#1020
SOUTH S Under Construction
T
PROJECT NAME: Hawkins and 12th Ave
LOCATION : Hawkins and 12th Ave
MAP & PARCEL : 09313055700 and 09314059000
REQ CAP (GPD) : 261,650
M H ENTRY PT : 093-14-043
IDU : 53
Offsite water main improvements will be necessary to
DATE : 3/31/2021
provide this development with adequate fire flow.
Maintaining separate storm and sanitary sewer will also
be required within the Demonbreun basin.

Volume of Closest Frequency of Closest Projects Defined to Discharge of Receiving Stream Meeting CD TOTAL
Downstream Overflow Downstream Overflow Abate SSO Public Exposure Milestones
(15 POINTS) (15 POINTS) (25 POINTS) (15 POINTS) (15 POINTS)
15 15 25 10 15 80

DRY
PEAK DAILY FLOW (MGD) 2.30
SYSTEM CAPACITY (MGD) 4.06

AVAILABLE CAPACITY (MGD) THAT CAN BE ALLOCATED: 0.95

PERCENT OF TOTAL CAPACITY BASED ON STANDARD 350 G.P.D.


PER UNIT DISCHARGE :
SEWER WATER
1 YEAR COMMITMENT 30% : $516,120 $308,550

2 YEAR COMMITMENT 55% : $946,220 $565,675

3 YEARS OR MORE 100% : $1,720,400 $1,028,500

JML
Development Services Water/Sewer Transmittal Form

Deliver to MWS Plans Intake Sent By


Reviewer/Attn: Name
David Brewington Mary McGowan
Mail: 800 Second Avenue South Company
Kimley-Horn
P.O. Box 196300
Address
Nashville, TN 37219-6300
Line 1 214 Oceanside Drive
Courier: 800 Second Avenue South City, State,
Nashville, TN 37204
Nashville, TN 37219-6300 Zip
615-862-4588 Phone (615) 800-4004
Date: 03/08/2021 Email mary.mcgowan@kimley-horn.com

Delivery Method
Hand Deliver: Courier: Mail / UPS / FedEx: Other:__________________
Email

Submission (check all that apply)


New Submittal: Resubmittal (Plan not approved yet): Plans for PreCon: #of Sets:

Easements: ✔ Record Drawings (As-Builts): ✔ Check (Include Fee Worksheet):

Water Project #WSWE: Project in the CSS? YES NO

Sewer Project #WSSE: Other:


Capacity Request
List ALL Contents of Package (new
Project Name: Hawkins Mixed Use plans, revised plans, as-built
drawings, calculations, check,
easement docs, etc.):
Project Address 1000 Hawkins Street
1.
City, State, Zip Nashville, TN 37203
2. Request for Water and Sewer Availability
Parcels 09313055700
(STANPAR or APN) 09314059000 3. Water and Sewer Service Calculations

4. Utility Connection Locations

5. MWS Transmittal Form

*Complete all requested information on this form. Incomplete submittals will not be entered
into the MWS system (Cityworks) until verified complete by Sender.