Grid Solutions
Reason RPV311
Digital Fault Recorder With Fault Location and PMU Situational Awareness
• Waveform recorder with samples per
GE’s Reason RPV311 provides comprehensive digital fault recording, accurate fault location cycle
and phasor measurement recording, enabling improved transmission system reliability. Along
with the Reason RA33x remote acquisition units and the Reason RT43x GNSS Master Clock, • Disturbance and continuous
the RPV311 monitors and records electrical quantities to deliver the performance, modularity, disturbance recorder
and flexibility needed for transmission system applications. • Trend Recorder & sequence of events
recorder
High Density • Flicker and harmonics measurement
With up to 64 analogue, 256 digital inputs and up to 320 GOOSE inputs per processing unit you
• Subscribes to Sampled Values IEC
can easily have your whole plant or substation information at a single device. With over 30GB of
61850-9-2LE
solid-state internal memory, the RPV311 can keep the data for or even years without external
storage devices. • PMU IEEE C37.118.1/2-2011/1a-2014
compliance
Turnkey Engineering and Retrofitting
• WMU (Waveform Measurement
Our engineering team can deliver a solution customized to your needs, from drafting to Unit) for subsynchronous oscillation
commissioning. Take advantage of our retrofitting solution and swap your old equipment monitoring
without laying any new cables. From water to earthquake resistant panels, you can have it your
way.
High Density I/O
Future Proof • Up to 64 analog inputs
Protect your investment for future compatibility and reap the benefits of the newest reliability • Up to 256 binary inputs
technology available, such as continuous recording for fault and disturbance, DNP3, IEC61850
GOOSE and Sampled Values communication.
• Up to 320 GOOSE inputs
OPTICAL IRIG-INPUT
Travelling Wave Fault Location (TWFL)
Signal IRIG-B004
Traveling wave (TW) fault location (TWFL) is an extremely precise Wavelength 820 nm
method to define where a fault occurred on a transmission line, or Fiber type Multimode 62.5 / 125 µm
span length of conductors. Such accuracy to within a few hundreds Connector ST
of meters of the actual fault point is not possible to achieve with Sensitivity - 24 dBm
traditional impedance-based fault location, which errors are in the
range of several kilometers. The highly reliable fault location system DRY-CONTACT RELAY OUTPUTS
uses an innovative and patented combination of travelling wave and Max Voltage 250 Vdc
fault detection algorithms where the triggers normally associated with Max Current 1A
Digital Fault Recorders (DFRs) can also be used to record TW events. Load Resistive
Precision is not affected by line and fault impedance, mutual coupling 1 normally closed
effects (parallel lines), load, or compensation circuits (capacitor banks). Contact Numbers
3 normally open
The DR Manager software automatically downloads the traveling wave Isolation Level 3.3 KVdc
2 GEGridSolutions.com
TW ANALOG ACQUISITION RA333 TYPE TESTS RPV311
Resolution 8 bits IEC 61000-4-2:2008
8kV contact / 15KV air (level 4)
(Electrostatic discharge)
Sampling frequency 5 MHz
IEC 61000-4-3:2006 (RF
Time skew 0 µs 10 V/m
immunity)
IEC 61000-4-4:2012 (Fast
2 KV @ 5KHz (level 3)
POWER SUPPLY transient disturbance)
IEC 61000-4-5:2005 (Surge Differential mode: 2KV
100-250 V dc immunity) Common mode: 1KV (level 3)
Nominal voltage range 24/48 Vdc
110-240 V ac
IEC 61000-4-6:2008
80-300 V dc 10V
Maximum voltage range 18 – 75 Vdc (Conducted RF immunity)
88-264 V ac
IEC 61000-4-8:2009 (Power 30A/m continuous
50 / 60 Hz 50 / 60 Hz magnetic immunity) 300A/m @ 1s.
Frequency
± 3 Hz ± 3 Hz
- A.C. and d.c. voltage dips
MAX 60 VA Test level: 0% residual voltage
Power consumption RPV311 MAX 50W
Typically 50W Duration time
Power consumption RA331, RA332 MAX 20 VA MAX 30W a.c.: 1 cycle
d.c.: 16,6ms
Power consumption RA333 MAX 30 VA MAX 30W - Test level: 40% residual voltage
Isolation Level 3.3 KVdc 3.3 KVdc Duration time
IEC 61000-4-11:2004
a.c.: 12 cycles
IEC 61000-4-29:2000 (Voltage
d.c.: 200ms
dip, short interruptions and
FIBER-OPTIC LINKS - Test level: 70% residual voltage
voltage variation immunity
Duration time
Wavelength 1300 nm tests)
a.c.: 30 cycles
Fiber Type Multimode 62.5 / 125 µm d.c.:500 ms
- A.C. and d.c. voltage interruptions
Connector ST Test level: 0% residual voltage
Emission Power - 20 dBm Duration time
Receiver sensitivity - 32 dBm a.c.: 300 cycles
d.c.: 5s
Maximum Applicable Power - 14 dBm
Zone A
IEC 61000-4-16:2009
Test voltage
(Conducted RF immunity, 0 to
Differential mode: 150 V rms
ENVIRONMENTAL TESTS 150 kHz)
Common mode: 300 V rms
Equipment RPV311 RA33x Test level:
IEC 61000-4-17:1999 (Voltage
IEC 60068-2-1 -40°C, 16 hours (Cold) -40°C, 16 hours (Cold) 15 % of rated d.c. value
ripple)
Test frequency: 120Hz, sinusoidal waveform
IEC 60068-2-2 +55°C, 16 hours (Dry heat) +85°C, 16 hours (Dry heat)
IEC 61000-4-18:2006 Voltage oscillation frequency: 1MHz
95% no condensation, 55°C 95% no condensation, (Damped Differential mode:
IEC 60068-2-30
(Damp heat) 55°C (Damp heat) oscillatory wave immunity 1kV peak voltage;
-40°C to 55ºC / 9 hours -40°C to 85ºC / 9 hours test) Common mode 2,5kV peak voltage
IEC 60068-2-14 / 2 cycles (Change of / 2 cycles (Change of Shut-down ramp: 60s
temperature) temperature) Gradual Startup Power off: 5m
IEC 60255-21-1 Class 2 (Vibration) Class 2 (Vibration) Start-up ramp: 60s
GEGridSolutions.com
3
R33X DC TRANSDUCER INPUTS R33X VOLTAGE INPUTS (50/60 HZ)
Full Scale ± 10 V ± 20 mA Nominal Voltage (V_n) 115 V
Voltage range 0.02-230 V
Input range - 10 to + 10 V - 20 to 20 mA
Analog Input Accuracy ± 0.1 % of FS magnitude range
± 0.1 % of FS magnitude ± 1 % of FS magnitude
Analog Input Accuracy Impedance > 200 kΩ
range range
Impedance > 5 kΩ 10 Ω Burden In < 0.1 VA
Continuous Overload 230 V (2 x V_n)
Maximum Overload (1 s) 460 V (4 x V_n)
ENCLOSURE PROTECTION IEC 60529
Equipment RPV311 RA33x
RA33X CURRENT INPUTS (50/60 HZ)
Front flush mounted with panel IP54 IP54
Resolution 16 bits
Rear and sides IP20 IP10
Acquisition Rate 256 ppc
Bandwidth DC to 3.0 kHz
SAFETY TESTS
Attenuation @ 3000 Hz < 0.1 dB
Safety IEC 61010-1
Attenuation @ 6400 Hz > 30 dB
Inpulse - 5KV
Dielectric withstand - 3,3KVDC for 60 Time skew 0 µs
IEC 60255-5
seconds Frequency Tracking Range Nominal Frequency ±5Hz
Insulation > 100M Ω
4 GEGridSolutions.com
RPV311 Ordering
13 Firmware 13
Details on functions and protocols selection can be obtained on the GE Grid online store
GEGridSolutions.com
5
RA331 Ordering
P Voltage inputs 115 V / Current inputs 100 mA; full-scale 100 mA (Ith = 2 A)
X Not installed
P Voltage inputs 115 V / Current inputs 100 mA; full-scale 100 mA (Ith = 2 A)
X Not installed
Digital Inputs 1 to 16 1 24 V / 48 V
2 125 V
3 250 V
X Not installed
Digital Inputs 17 to 32 1 24 V / 48 V
2 125 V
3 250 V
X Not installed
Details on functions and protocols selection can be obtained on the GE Grid online store
6 GEGridSolutions.com
RA332 Ordering
P Voltage inputs 115 V / Current inputs 100 mA; full-scale 100 mA (Ith = 2 A)
X Not installed
P Voltage inputs 115 V / Current inputs 100 mA; full-scale 100 mA (Ith = 2 A)
X Not installed
P Voltage inputs 115 V / Current inputs 100 mA; full-scale 100 mA (Ith = 2 A)
X Not installed
P Voltage inputs 115 V / Current inputs 100 mA; full-scale 100 mA (Ith = 2 A)
X Not installed
Digital Inputs 1 to 16 1 24 V / 48 V
2 125 V
3 250 V
X Not installed
Digital Inputs 17 to 32 1 24 V / 48 V
2 125 V
3 250 V
X Not installed
Details on functions and protocols selection can be obtained on the GE Grid online store
GEGridSolutions.com
7
RA333 Ordering
Model Type RA333 * * * * * * C C RA333 Travelling Wave and DFR Acquisition Module for RPV311
P Voltage inputs 115 V / Current inputs 100 mA; full-scale 100 mA (Ith = 2 A)
X Not installed
P Voltage inputs 115 V / Current inputs 100 mA; full-scale 100 mA (Ith = 2 A)
X Not installed
Digital Inputs 1 to 16 1 24 V / 48 V
2 125 V
3 250 V
X Not installed
Digital Inputs 17 to 32 1 24 V / 48 V
2 125 V
3 250 V
X Not installed
Details on functions and protocols selection can be obtained on the GE Grid online store
GEGridSolutions.com
IEC is a registered trademark of Commission Electrotechnique Internationale. IEEE is a registered
trademark of the Institute of Electrical Electronics Engineers, Inc. Modbus is a registered trademark of
Schneider Automation. NERC is a registered trademark of North American Electric Reliability Council.
NIST is a registered trademark of the National Institute of Standards and Technology.
GE, the GE monogram and Reason are trademarks of General Electric Company.
GE reserves the right to make changes to specifications of products described at any time without notice
and without obligation to notify any person of such changes.
GEA-33113-ltr