Basement ceiling Basement ceiling


created on 5.5.2021

Thermal protection Moisture proofing Heat protection


No condensate Temperature amplitude damping: 96
U = 0,278 W/(m²K) phase shift: 7,8 h
Thermal capacity inside: 368 kJ/m²K
EnEV Bestand*: U<0,3 W/(m²K)

excellent insufficient excellent


www.ubakus.de
insufficient excellent insufficient

10 1
50 2

150 3
322,5

100 4
12,5 5

Commercial use only with Plus-, PDF- or Profi-Option (from 2.99 € / month plus VAT).
1 Lamination (10 mm) 3 Reinforced concrete (150 mm) 5 Gypsum board (12,5 mm)
2 Cement screed (50 mm) 4 Expanded polystyrene (100 mm)

Impact of each layer and comparison to reference values


For the following figure, the thermal resistances of the individual layers were converted in millimeters insulation. The scale
refers to an insulation of thermal conductivity 0,033 W/mK.

Lamination Gypsum board


Cement screed
Reinforced concrete (1%)
Expanded polystyrene (EPS) Equivalent
insulation thickness
(WLS 033)

0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 mm
8 95 u d ,1
41
0 ba an =0
N zV
O eu est d U
DI u t N B n u us
ch 14 EV ta ha
es nEV En Bes uba ss
iv
m E Ne u
är 20 5 5 Pa
W 20 V16 uba =0,2 = 0,1
G E e
GE En 20 N V U ßn. sU
20 San elm
M a 5 2 H au
G 5 0 , r -
GE E inz W
Kf W U= 40 -Lite
E u B f W 3
W a
Kf eub eG uK
N ärm uba
EW Ne

Inside air : 20,0°C / 50% Thickness: 32,2 cm


Non-heated room: 5,0°C / 80% sd-value: 21,2 m Weight: 460 kg/m²
Surface temperature.: 18,9°C / 5,2°C Heat capacity: 420 kJ/m²K

*Comparison to the maximum U-value according to the german EnEV 2014/2016 for first-time installation or renewal of Decken nach unten gegen Page 1
Erdreich oder unbeheizte Räume (Anlage 3, Tabelle 1, Zeile 5a).
All statements without guarantee

Basement ceiling, U=0,278 W/(m²K)

Temperature profile
Temperature profile
20 Temperature
1 2 3 4 5 Dew point
18
16
1 Lamination (10 mm)
Temperature [°C]

14
2 Cement screed (50 mm)
12 3 Reinforced concrete (150 mm)
10 4 Expanded polystyrene (100 mm)
8 5 Gypsum board (12,5 mm)

6
4
2
0 50 100 150 200 250 300 350
Inside [mm]

Commercial use only with Plus-, PDF- or Profi-Option (from 2.99 € / month plus VAT).
www.ubakus.de Outside

Temperature and dew-point temperature in the component. The dew-point indicates the temperature, at which water vapour
condensates. As long as the temperature of the component is everywhere above the dew-point temperature, no
condensation occurs. If the curves have contact, condensation occurs at the corresponding position.

Layers (from inside to outside)


# Material λ R Temperatur [°C] Weight
[W/mK] [m²K/W] min max [kg/m²]
Thermal contact resistance* 0,170 18,9 20,0
1 1 cm
Lamination 0,130 0,077 18,6 18,9 5,0
2 5 cm
Cement screed 1,400 0,036 18,5 18,6 100,0
3 15 cm
Reinforced concrete (1%) 2,300 0,065 18,2 18,5 345,0
4 10 cm
Expanded polystyrene (EPS) 0,033 3,030 5,4 18,2 2,0
5 1,25 cm
Gypsum board 0,250 0,050 5,2 5,4 8,5
Thermal contact resistance* 0,170 5,0 5,2
32,25 cm Whole component 3,598 460,5
*Thermal contact resistances according to DIN 6946 for the U-value calculation. Rsi=0,25 and Rse=0,04 according to DIN
4108-3 were used for moisture proofing and temperature profile.

Surface temperature inside (min / average / max): 18,9°C 18,9°C 18,9°C


Surface temperature outside (min / average / max): 5,2°C 5,2°C 5,2°C

Page 2
All statements without guarantee

Basement ceiling, U=0,278 W/(m²K)

Moisture proofing
For the calculation of the amount of condensation water, the component was exposed to the following constant climate for
90 days: inside: 20°C und 50% Humidity; outside: 5°C und 80% Humidity (Climate according to user input).
This component is free of condensate under the given climate conditions.

# Material sd-value Condensate Weight


[m] [kg/m²] [Gew.-%] [kg/m²]
1 1 cm Lamination 0,30 - - 5,0
2 5 cm Cement screed 0,75 - 100,0
3 15 cm Reinforced concrete (1%) 19,50 - 345,0
4 10 cm Expanded polystyrene (EPS) 0,50 - 2,0
5 1,25 cm Gypsum board 0,13 - 8,5
32,25 cm Whole component 21,18 460,5

Humidity
The temperature of the inside surface is 18,9 °C leading to a relative humidity on the surface of 54%.Mould formation is not

Commercial use only with Plus-, PDF- or Profi-Option (from 2.99 € / month plus VAT).
expected under these conditions.
The following figure shows the relative humidity inside the component.

100 Relative humidity (%)


1 2 3 4 5 saturation point
90
80
Relative humidity (%)

1 Lamination (10 mm)


70
2 Cement screed (50 mm)
60
3 Reinforced concrete (150 mm)
50 4 Expanded polystyrene (100 mm)
40 5 Gypsum board (12,5 mm)
30
20
10
0
0 50 100 150 200 250 300 350
Inside [mm]
www.ubakus.de Outside
Notes: Calculation using the Ubakus 2D-FE method. Convection and the capillarity of the building materials
were not considered. The drying time may take longer under unfavorable conditions (shading, damp / cool
summers) than calculated here.

Page 3
All statements without guarantee

Basement ceiling, U=0,278 W/(m²K)

Heat protection
The following results are properties of the tested component alone and do not make any statement about the heat protection
of the entire room:

Temperature profile
This document has been generated by the U-value calculator on www.ubakus.de. If you are harmed by the free use of these contents, the service provider is only liable in case of

36 Temperature at 3pm, 11am and 7am


34 1 2 3 4 5 Temperature at 7pm, 11pm and 3am
intent and gross negligence on the part of the service provider. For further information, please refer to the terms and conditions at https://www.ubakus.de/agb

32
30 1 Lamination (10 mm)
Temperature [°C]

28 2 Cement screed (50 mm)


26 3 Reinforced concrete (150 mm)
24 4 Expanded polystyrene (100 mm)
5 Gypsum board (12,5 mm)
22
20
18

Commercial use only with Plus-, PDF- or Profi-Option (from 2.99 € / month plus VAT).
16
14
0 50 100 150 200 250 300 350
Inside [mm]
www.ubakus.de Outside

[°C] The surface temperature during the day


36 Outside
34 Inside
32
30
28
26
24
22
20
18
16
14 Phase shift: 7.8h
12 14 16 18 20 22 24 2 4 6 8 10 12
[time of day]
Top:Temperature profile within the component at different times. From top to bottom, brown lines: at 3 pm, 11 am and 7 am
and red lines at 7 pm , 11 pm and 3 am.
Bottom:Temperature on the outer ( red ) and inner ( blue ) surface in the course of a day. The arrows indicate the location of
the temperature maximum values . The maximum of the inner surface temperature should preferably occur during the
second half of the night.

Phase shift* 7,8 h Heat storage capacity (whole component): 420 kJ/m²K
Amplitude attenuation ** 96,2 Thermal capacity of inner layers: 368 kJ/m²K
TAV *** 0,010
* The phase shift is the time in hours after which the temperature peak of the afternoon reaches the component interior.
** The amplitude attenuation describes the attenuation of the temperature wave when passing through the component. A value of 10
means that the temperature on the outside varies 10x stronger than on the inside, e.g. outside 15-35 °C, inside 24-26 °C.
*** The temperature amplitude ratio TAV is the reciprocal of the attenuation: TAV = 1 / amplitude attenuation
Note: The heat protection of a room is influenced by several factors, but essentially by the direct solar radiation through windows and the
total amount of heat storage capacity (including floor, interior walls and furniture). A single component usually has only a very small
influence on the heat protection of the room.