I MATERIAL PROPERTIES

Yield Strength
- Top Flange : 360 Mpa :
- Bottom Flange : 360 Mpa :
- Web : 360 Mpa :

II SECTION PROPERTIES
A. TGA
Hw 2726 mm
B1 2330 mm
Bf1 475 mm
B2 1460 mm
BGA
Bf2 50 mm
tw 18 mm
tf1 24 mm
tf2 24 mm

B. TGB
Hw 2718 mm
B1 2330 mm
Bf1 500 mm
B2 1460 mm
BGB
Bf2 50 mm
tw 20 mm
tf1 32 mm
tf2 40 mm

C. TGC
Hw 2715 mm
B1 2330 mm
Bf1 500 mm
B2 1460 mm
BGC
Bf2 50 mm
tw 20 mm
tf1 35 mm
tf2 46 mm

III SUMMARY OF STRESSES


LIMIT STATES LOCATION STRESS (Mpa)
STRENGTH I
Top Flange 147.4
Bottom Flange 232.3
SERVICE II
Top Flange 158.6
Bottom Flange 181.3

IV SPLICE DESIGN
A-B
- Top Flange
Inner : 20 mm
Outer : 16 mm
- Bottom Flange
Inner : 18 mm
Outer : 10 mm
- Web
Inner : 18 mm
Outer : 16 mm

B-C
- Top Flange
Inner : 20 mm
Outer : 16 mm
- Bottom Flange
Inner : 18 mm
Outer : 10 mm
- Web
Inner : 18 mm
Outer : 16 mm
Tensile Strength
490 Mpa
490 Mpa
490 Mpa
Flange Calculations

1 Moment (kip-ft)

Superimposed Future
Noncomposite Composite Dead Wearing
Dead Load (DC1)
Load (DC2) Surface (DW)

( kNm) 336.226 67.787 70.499


conversion 0.7376
Load Combination 248.00 50.00 52.00
Deck Casting 0.00 0.00 0.00
Strength I - Positive 1.25 1.25 1.50
Strength I - Negative 0.90 0.90 0.65
Service II - Positive 1.00 1.00 1.00
Service II - Negative 1.00 1.00 1.00

2 Bolt Factored Shear Resistance

D bolt used : 24 mm (compare dulu nsba)


Fu: 825 Mpa

Location Bolt Type Bolt Area (sq-in) Kh

Flange A325 - Excluded 0.7015 Standard

3 Bolt Nominal Slip Resistance


3.1 Minimum Flexural Resistance
- Strength Limit State
Surface Condition Factor Hole Size Factor Pt (kip) Rn - Double
(Ks) (Kh) Shear (kip)
0.33 1.00 39.00 25.74

Rh : 1
α : 1
ɸf : 1
Fyf : 360 Mpa
fcf : 232.3 Mpa
Fcf : 296.15 Mpa

- Section Properties of Bottom Flange


ɸy : 0.95
ɸy : 0.8
Fy : 360 MPa
Fu : 490 MPa
tbot : 24 mm
Bbot : 1560 mm
dhole : 26 mm
s : 50 mm
g : 100 mm
Ag : 37440 mm2
For Line 1-1
n bolt : 25 pcs
Ns : 0 pcs
21190 mm
Anet 1-1 2
:

For Line 2-2


n bolt : 25 pcs
Ns : 0 pcs
21190 mm
Anet 2-2 2
:
21190 mm
Anet 2
:
24161.429 mm
2
Aeffective :
Pcf : 7155.407 kN

3.2 Determination of Flange Bolts


3.2.1 Shear Resistance : Strength Limit State
Grade : F10T/ 8.8
ɸbolt : 24.0 mm
Ns : 2 planes
Rr : kN/plane
Rr : kN
Nreq : pcs

4 Strength Limit State Design

Thickness
Location Width (mm) Width (in) (mm)

Top Flange - Outer Splice


475 18 68/97 16
Plate
Top Flange - Inner Splice
178.5 7 2/73 20
Plate
Bottom Flange - Inner 14 37/53
Splice Plate 373.333 18

Bottom Flange - Outer


Splice Plate 1360 53 44/81 10
Flange Agross (sq- Flange Anet
Location 0.84 (Fu/Fy)
in) (sq-in)

Top Flange - Left 1.14 17.67 Err:507


Top Flange - Right 1.14 17.67 Err:507
Bottom Flange - Left 1.14 58.03 Err:507
Bottom Flange - Right 1.14 58.03 Err:507
Flange Calculations

Moment (kip-ft)

Positive Live Load Negative Live


plus Impact (LL+ + Load plus Impact Deck Casting
I) (LL- + I)

3347.343 -2377.983 1762.473


0.7376
2469.00 -1754.00 1300.00 Factored (kip-ft)
0.00 0.00 1.40 1,820.00
1.75 0.00 0.00 4,771.25
0.00 1.75 0.00 -2,767.50
1.30 0.00 0.00 3,559.70
0.00 1.30 0.00 -1,930.20

mpare dulu nsba)

Rr - Single Shear Rr - Double Shear


ɸs Fu (ksi) Pt (kip)
(kip) (kip)
0.80 120 39.00 37.60 75.21

(Hybrid Factor)
(1.0, except that a lower value equal to (Fn/ Fyf) maybe use for flange where Fn is less than Fyf)
(Resistance factor for flexure)
(Specified minimum yield strength of the flange)
(Maximum flexural stress due to the factored load at the mid thickness of controlling flange at the point of spl
(Minimum flexural stress resistance, Fcf : 1/2((fcf/Rh)+ α. ɸf. Fyf) ≥ 0.75 α.ɸf.Fyf

(Resistance factor for yielding of tensioned member)


(Resistance factor for fracture of tensioned member)
(Yield stress of the connected material)
(Tensile stress of the connected material)
(Bottom flange thickness)
(Width of the bottom flange)
(Hole's diameter)
(Pitch of any two consecutive holes)
(Gage of the same two holes)
(Gross area)

(Number of bolts in line 2-2)


(Number of inclined lines in line 2-2)
(Net area based on line 2-2)
(Net area)
(Effective area, taken as minimum of Anett and Agross)
(Minimum design force, Pcf = Fcf.Ag for compression force and Pcf = Fcf.A effective for tension force)
Thickness (in) Total Agross (sq-in) % Difference Equally Divide Pfy? Design Force Ratio
Ag Inner/Outer for Splice Plates
Area
46/73 11.78 0.50
6.24% OK
63/80 11.07 0.50

56/79 20.83 0.50


1.18% OK
37/94 21.08 0.50

 F  F 
Ae   u u A n  0.84 u A n  A g
 F  F 
 y yf   yf 
P fy  F y A e
Ae ≤ Agross
Ae (sq-in) Pfy (kip) Controlling Flange Max. Design Force
(Eq. 2.1.1.1-3) for Splice Plates
(kip) AASHTO
C6.13.6.1.3b
Err:507 Err:507 Err:507 Err:507 Err:507
Err:507 Err:507 Err:507 Err:507
Err:507 Err:507 Err:507 Err:507 Err:507
Err:507 Err:507 Err:507 Err:507 Err:507
1.905

1kips 4.4482 kN
1ksi 6.894757 Mpa
n is less than Fyf)

lling flange at the point of splice)


270 ok

ve
for tension force)
Required Tension - Pt (kip)
Bolt Diameter (inc)
M 164 (A325) M253 (A490)
0.625 19 24
0.75 28 35
0.875 39 49
1 51 64
1.125 56 80
1.25 71 102
1.375 85 121
1.5 103 148