Mechanical Test
Check mounting and examine if there is any mechanical damage on the air diode
Mechanical Test
Test diverter F3W
Check mounting and examine if there is any mechanical damage on the diverter
Check the V-belt / gear motor of the diverter and adjust accordingly as per Inspection Test
Plan
Check the V-belt / gear motor of the diverter and adjust accordingly as per Inspection Test
Plan
H. Test Station
Carry-out mechanical test as per Inspection test plan to verify stations are properly installed
Bring the station in test mode and check voltage. Minimum voltage reading should be 22VDC
• Check the gear motor & gasket and ensure they are properly calibrated as per Inspection Test plan
• Check the bypass positions (normal, receiving, & dispatch) alignment while still in Test mode
• Check the dispatch storage chap and slide gates
• Check the air (vacuum, pressure, stop) in the station. Press 7+PTT=vacuum, 8+PTT=pressure
and 9+PTT=stop.
• Record results and comments in the Annexure 1 – “Pre-Testing & Commissioning Report”.
I. Control System
J. Send Test
Priors to Send Test, the following activities must be performed
• Display Test - Perform display test to control the function of the station keyboard. Press every
number of the keypad to verify it is properly working as per Inspection test plan.
• Keyboard Test - Control the function of the display and verify there is no mistake Check the
station controls for any damages like colloq scratches, colloq dents, etc.
• Check the station controls for any damages like colloq scratches, colloq dents, etc.
Send test shall be performed to test the function of the station by sending a carrier
to the station and back. This works when system is in READY status only
K. Send Check
Carriers should be already programmed
To Send a Carrier: Select the number of destination station and press PTT. Type "station
number" based on the station list and press "PTT" key ( "12345" + "PTT" ). If you
enter a valid number, CARRIER appears in upper display line, the text associated with station
number appears in lower display line and you can insert the carrier within the next 15 seconds,
otherwise your transmit will be cancelled after this time.
Insert a carrier in the station and the transit will be started. The transmit is realized
immediately if the system is READY or later when the current running transmit is finished