1. Bus coupler is very essential in the arrangement
I. Single bus II. Double bus, double breaker III. Main and transfer bus IV. All of the above 2. For cost and safety, the outdoor substations are installed for voltages above I. 11 kV II. 33 kV III. 60 kV IV. 110 kV 3. A mho relay is used for protection of: I. Protection of a transformer against external fault II. Long Transmission Line III. Protection of a transformer against all the internal faults and external fault IV. Medium Length lines 4. A relay which measures impedance or a component of the impedance at the relay location is known as I. Induction Relay II. Moving Coil Relay III. IDMT Relay IV. Distance Relay 5. The under voltage relay can be used for 1. Generators 2. Busbars 3. Motors 4. All of the above 2 marker 1. Question 1. What Are The Common Types Of Generator Faults? Answer : The common types of faults occurring in synchronous generators are: Stator winding faults (phase to phase faults, phase to earth faults, inter turn faults), Rotor winding faults (conductor to earth faults, open circuit faults, inter turn faults), failure of prime mover, failure of the field, unbalanced loading, over loading, over-voltage at generator terminals, over-speed, ventilation failure, loss of excitation. Question 2.For What Type Of Faults Does Differential Protection Is Provided? Answer : Differential protection responds to the phasor difference between two or more electrical quantities. It operates for the internal faults occur in generators or transformers. For external faults differential protection does not operate. Question 3. Why It Is Not Necessary To Provide Protection For Turn To Turn Fault In Alternator? Answer : The coils of the modern alternators are single turn and therefore it is not necessary to provide protection for turn to turn faults Question 4. What Is Advantage Of Using Percentage Differential Relay Protection? Answer : o It does not require CTs with air gaps or special balancing features o It permits a low fault setting to be used and this ensures maximum protection of the windings o It ensures complete stability under the most severe through fault conditions Question 5. Which Type Of Relays Are Used For The Merz-price Protection System For Alternator? Answer :Merz-Price protection is differential protection provided for the alternator. The relays used in the Merz-Price protection system of alternator are instantaneous electro-magnetic type protection.
16 marker
1)Explain the electrical circuit of the generator. With the suitable
diagram. ANSWER- 2)Explain the various faults and abnormal operating conditions for a generator protection. Answer- 3) Expain the loss of excitation with examples. Answer- 4)Explain the rotor fault and Abnormal operating conditions. Answer- 5) Explain Earth Leakage Protection for Single-phase Load. Answer-