Professional Documents
Culture Documents
USA Elementary Steady Flow Chapter 05
USA Elementary Steady Flow Chapter 05
USA Elementary Steady Flow Chapter 05
3. If, in the preceding example, the feed water entering has a velocity
of 3 m/s and the steam leaving the super heater has a velocity of
P1 = 15 psia T1 = 40+ 460 = 520R
50 m/s. Find:
P2 = 60 psia T2 = 200 + 460 = 660R
(A) The additional heat required to accommodate the change in q12 = - 21.4 Btu/lb
kinetic energy across the boiler, J/kg wk12
= q12 + h1 - h2
J
(B) The percentage error introduced by neglecting the kinetic
where : h1 - h2 Cp T 0.24(520 660) 33.6
energy change.
wk12
= -21.4 - 33.6 = - 55 Btu/lb (on)
J
V22 -V12 (50)2 (3)3 6. A sample of steam is removed from a steam line where the
(A) q12 = h2 - h1 - 1245 J / kg
2gc 2(1) pressure is 215 psia and passed through an Ellison throttling
calorimeter. The calorimeter thermometer reads 250 F and the
Btu J / kg
(B)q12 = 1259.2 = 2930 x 10 3 J/kg barometer is standard. Find for the line steam:
lb Btu / lb
2326
1245.5 x 100 A. The enthalpy
Error = 0.043% B. The quality
2930 x 103
C. The entropy
D. The temperature to the nearest whole degree
4. Saturated water at 250F enters a centrifugal main feed pump and
is discharges at 1200 psia. The pump efficiency is 60% and the
delivery rate is 125,000 lb/hr. Find:
P1 = 215 psia
(A) The total head developed by the pump, ft
(B) The water horsepower, WHP P2 = 14.696 psia T2 = 250F
(C) The brakepower, BHP (A) from table 3:
(D) The ideal (isentropic) pump work, Btu/lb h2 = 1168.8
(E) The actual pump work, Btu/lb
(F) The estimated temperature of the water at discharge. h1 = h2 = 1168.8 Btu/min throttling(h=constant)
(B) from table 2 for 215 psia: h g 1200.3; hfg 838.1
h1 hg - m1hfg
t1 = 250F (sat.water) ; P1 = 29.8 psia hg - h1 1200.3 1168.8 31.5
1 0.017001 ft 3 / lb ; P2 1200 psia m1 0.0376
hfg 838.1 838.1
h1 218.59 Btu/lb ; epump 60% x1 = 1 - m1 = 1 - 0.0376 = 0.9624 = 96.24%
M'=125,000 lb/hr (C) s1 sg m1sfg
V1 V2 ; Z1 Z2 1.5403 0.0376(0.9887) 1.5031 Btu/lb.R
(D) t1 387.97 388F
7. In a lube oil cooler, oil enters at 140F and leaves at 100F, at the
rate of 400 lb/min. The cooling medium is sea water , which enters
at 60F. The average specific heat of the oil is 0.50 Btu/lb.F and the
salt water is 0.94 Btu/lb.F. If the flow of the sea water is at the rate
of 500 lb/min, find the overload discharge temperature.
t1 = 40°F t 2 100F t 3 60F
M'A = 400 lb/min; C A = 0.50 Btu/lb.F
M'B = 500 lb/min; CB 0.94 Btu/lb.F
M'A h1 - h2 M'B h4 - h3 Btu / min
M'ACA t1 - t 2 M'BCB t 4 - t 3 Btu / min M'o = 60,000 lb/hr
400 0.50 140-100 Co 0.50 Btu/lb.F
t4 - t3 = = 17
500 0.94 A = 258 ft 2
t4 - 60 = 17 t 4 = 77°F A. Q' = M'oCo t1 t 2 (60,000)(0.50)(145 120)
= 750,000 Btu/hr
8. Steam enters the condenser of propulsion plant at 0.50 psia and a 55 45
quality of 89 percent at the rate of 100,000 lb/hr and with a velocity m 1 2 49.8F
of 1000 ft/s. It leaves the condenser hotwell as saturated liquid 1 55
ln ln 45
without any change in pressure but a velocity of 10 ft/s. The salt 2
water inlet ( injection ) temperature is 70F and the discharge
(overboard ) temperature is 85F. Sea water has a specific heat of
0.94 Btu/lb.F and a density of 64 lb/ft3 . The injection and
overboard velocities are substantially equal. Calculate the
following:
100,000 953.2
M'A q12 = 1,588,700 Btu/min
60
(b) (-)Q'12 Q '34 M 'B xCB t 4 t 3
Q '34 1,588,700
M'B = 112,670 lb/min
CB t 4 t3 0.94(85 70)
gal M '
flow, (gpm) = 7.481
ft 3 B
7.481112,670
= 13,170 gpm
64
9. A counter-flow lubricating oil cooler with a net heat transfer area of
258 ft2 cools 60,000 lb of oil per hour from a temperature of 145F
at inlet to 120F at discharge. The temperatures of the cooling
water are 75F and 90F respectively, and the specific heat of the oil
is 0.50 Btu/lb.F. Calculate:
Q ' Ms hs 220,000 1434.2 1203.1 51x10 6 Btu / hr
A. The value of the overall heat transfer coefficient under these
operating conditions, Btu/hr.ft2F, 1250 935
m 1085F
B. and the required area for a parallel flow device having the 1250
ln
same capacity under identical operating conditions. 935
Q' 51x106
U 29 Btu / hr ft 2F
A 1620 1085