You are on page 1of 37

7SH68974-02D 1/39

TENKEY DATA ADDRESS LIST


FOR
M-800-V TYPE
M/E REMOTE CONTROL SYSTEM

SHIPYARD : SAMSUNG HEAVY INDUSTRIES CO., LTD.

S.NO. : SN2284
ENGINE TYPE : MAN 6G50ME-C9.6 Tier-III

REVISION
1. NABTESCO SHOP TEST : 2019.08.
2. SEA TRIAL : 2020.10.15
3.
4.

PASSWORD : 0725

READOUT OPERATION OF DATA


INPUT THE ADDRESS FOR THE DATA TO BE READ OUT WITH THE KEYBOARD,
AND THE ADDRESS IS DISPLAY ON THE ADDRESS DISPLAY SECTION AND
THE DATA ON THE DATA DISPLAY SECTION.
S.NO.SN2284 7SH68974-02D 2/39
FOR CONTROL
ADJUSTABLE
TENKEY RANGE
SETTING VALUE
ADDRESS DESCRIPTION UNIT
LOWER UPPER 1 2 3 4
000
001 SPEED LIMIT SET RPM
002 SPEED LIMIT SET. RPM 0 120 88 75
003 HANDLE MATCH LEVEL RPM 0 10 3
004
005 SPEED SET. ORDER OF AS. FULL MAX. RPM 0 120 74 61
006 SPEED SET. ORDER OF AS. FULL MAX. RPM 0 120 74 61
007 SPEED SET. ORDER OF AS. FULL RPM 0 120 74 61
008 SPEED SET. ORDER OF AS. HALF RPM 0 120 67 50
009 SPEED SET. ORDER OF AS. SLOW RPM 0 120 50 33
010 SPEED SET. ORDER OF AS. DEAD SLOW RPM 0 120 40 22
011 SPEED SET. ORDER OF AS. D.S. MIN. RPM 0 120 20 18
012 SPEED SET. ORDER OF STOP RPM 0 120 0
013 SPEED SET. ORDER OF AH. D.S. MIN. RPM 0 120 20 18
014 SPEED SET. ORDER OF AH. DEAD SLOW RPM 0 120 40 22
015 SPEED SET. ORDER OF AH. SLOW RPM 0 120 50 33
016 SPEED SET. ORDER OF AH. HALF RPM 0 120 67 50
017 SPEED SET. ORDER OF AH. FULL RPM 0 120 70 61
018 SPEED SET. ORDER OF N. FULL MIN. RPM 0 120 71 63
019 SPEED SET. ORDER OF N. FULL (MAX.) RPM 0 120 79 74.1
020 SPEED SET. ORDER OF N. FULL MAX. RPM 0 120 79 74.1
021
022
023 SPEED SET. ORDER OF SLOW DOWN RPM 0 120 50 31.6
024
025
026 AHEAD IGNITION LEVEL RPM 0 50 10
027 ASTERN IGNITION LEVEL RPM -50 0 -10
028 CRASH ASTERN DETECT. LEVEL RPM 0 120 10
029
030
031
032
033
034
035
036
037
038
039
040 KNUCKLE POINT OF LOAD DOWN PROGRAM RPM 0 120 76
041 PROGRAM START POINT RPM 0 120 71 63.2
042 KNUCKLE POINT OF LOAD UP PROGRAM RPM 0 120 76
043 LOAD DOWN PROGRAM RESET LEVEL RPM 0 120 71 55.5
044 ASTERN PROGRAM START POINT RPM 0 120 120
045
046
047
048
049
S.NO.SN2284 7SH68974-02D 3/39
FOR CONTROL
ADJUSTABLE
TENKEY RANGE
SETTING VALUE
ADDRESS DESCRIPTION UNIT
LOWER UPPER 1 2 3 4
050 EXH. GAS H.D. ALARM CANCEL RPM 0 120 30 10
051 PISTON C.O. NON-FLOW ALARM CANCEL RPM 0 120 120 10
052 S/G REVO. OK LEVEL DETECT. RPM 0 120 120
053 START BLOCK ALARM DETECT LEVEL RPM -10 120 5 0
054 SCAV. AIR BOX FIRE ALARM CANCEL RPM 0 120 120 10
055 AXIAL VIBRATION HIGH ALARM CANCEL RPM 0 120 120 10
056
057
058 CONTROL POS. P.B.SW. DETECT TIMER SEC. 0.1 1 0.2
059 E/S P.B.SW. OFF DELAY TIMER SEC. 0.1 2 0.5
060
061 RANGE FOR RED MARK - 0 50 10
062 RANGE FOR GREEN MARK 1 - 0 50 18 15
063 RANGE FOR GREEN MARK 2 - 0 50 30
064
065
066
067
068
069
070 START AIR LOW PRES. DETECT. TIMER SEC. 0.1 10 1
071
072
073 ECS ABNORMAL TIMER SEC. 0.1 10 0.2
074
075 START BLOCK DETECT TIMER SEC. 0.1 10 0.2
076 START FAILURE DETECT TIMER SEC. 0.1 10 0.2
077 ENGINE NOT READY DETECT TIMER SEC. 0.1 10 0.2
078 AUX. BLOWER FAIL. DETECT TIMER SEC. 0.1 10 0.2
079
080 CRASH ASTERN DETECT.TIMER SEC. 0.1 999 30
081
082
083
084
085
086
087
088
089
090
091
092
093
094
095
096
097
098
099
S.NO.SN2284 7SH68974-02D 4/39
FOR CONTROL
ADJUSTABLE
TENKEY RANGE
SETTING VALUE
ADDRESS DESCRIPTION UNIT
LOWER UPPER 1 2 3 4
100 CONT. POS. C/O ALARM TIMER SEC. 0.1 10 5
101 F/E REQUEST FEED BACK TIMER (NOT USE) SEC. 0.1 999 120 600
102 S/B REQUEST FEED BACK TIMER (NOT USE) SEC. 0.1 999 120 600
103 F/E FAIL. DETECT TIMER (NOT USE) SEC. 0.1 5 0.5
104 S/B FAIL. DETECT TIMER (NOT USE) SEC. 0.1 5 0.5
105
106 ELECT. SHAFT ABNORMAL DETECT. TIMER (NOT USE) SEC. 0.2 10 1
107
108
109 RPM SIGNAL DEVIATION ABNORMAL DETECT. TIMER SEC. 0.2 5 3
110 LOAD UP PROGRAM LOWER ZONE MIN. 0.1 999 30
111 LOAD UP PROGRAM UPPER ZONE MIN. 0.1 999 60
112 LOAD DOWN PROGRAM MIN. 0.1 999 3 15
113 LOAD UP PROGRAM IN AS RANGE MIN. 0.1 999 2
114
115 HARBOR SPEED DECREASING TIME SCHEDULE RPM/MIN. 0.1 999 240
116 DECREASING TIME SCHEDULE FOR CRASH AS. & STOP OPERATE RPM/MIN. 0.1 999 400
117 LOAD UP PROGRAM BY-PASS INCREASINGTIME SCHEDULE RPM/MIN. 0.1 999 180
118 LOAD DOWN PROGRAM (UPPER) MIN. 0.1 999 2
119 HARBOR SPEED INCREASING TIME SCHEDULE RPM/MIN. 0.1 999 150
120
121 SCHEDULER OUT SIGNAL ZERO DETECT LEVEL 0 5 0.2
122 LOAD UP PROGRAM LOWER ZONE F. (1:USE) - 0 1 0
123 LOAD UP PROGRAM UPPER ZONE F. (1:USE) - 0 1 0
124 LOAD DOWN PROGRAM UPPER ZONE F. (1:USE) - 0 1 0
125 LOAD DOWN PROGRAM LOWER ZONE F. (1:USE) - 0 1 0 1
126 LOAD DOWN PROGRAM SELECT (0:HANDLE, 1:ECS F/B) - 0 1 1
127
128
129 RPM SIGNAL DEVIATION ABNORMAL DETECT. LEVEL RPM 0 10 5
130 FUEL INDEX ZERO DETECT. FOR REPOSE FUNCTION % 0 50 5
131
132
133
134
135
136
137
138
139
140 ALARM CANCEL TIMER (EXH. GAS H.D.) SEC. 0.1 999 600
141 ALARM CANCEL TIMER (PISTON C.O. NON-FLOW) SEC. 0.1 999 600
142 ALARM CANCEL TIMER (SCAV. AIR BOX FIRE) SEC. 0.1 999 600
143 ALARM CANCEL TIMER (AXIAL VIBRATION HIGH) SEC. 0.1 999 600
144
145
146
147
148
149
S.NO.SN2284 7SH68974-02D 5/39
FOR CONTROL
ADJUSTABLE
TENKEY RANGE
SETTING VALUE
ADDRESS DESCRIPTION UNIT
LOWER UPPER 1 2 3 4
150
151
152
153
154
155 PULSE WIDTH FOR DATA REQUEST SIGNAL (ON) TO AMS SEC. 0.1 999 9
156 PULSE WIDTH FOR DATA REQUEST SIGNAL (OFF) TO AMS SEC. 0.1 999 300
157
158
159
160 REVOLUTION SIGNAL ASTERN MAX. RPM -120 120 -120
161 REVOLUTION SIGNAL STOP CONDITION RPM -120 120 0
162 REVOLUTION SIGNAL AHEAD MAX. RPM -120 120 120
163 REVOLUTION SIGNAL ASTERN MAX. RPM -120 120 -120
164 REVOLUTION SIGNAL STOP CONDITION RPM -120 120 0
165 REVOLUTION SIGNAL AHEAD MAX. RPM -120 120 120
166
167
168 SPEED COMMAND SIGNAL SET FOR AMS OFFSET RPM -999 999 0
169 SPEED COMMAND SIGNAL SET FOR AMS - 0 10 10
170
171
172
173
174
175
176
177
178
179
180 HYSTERESYS RPM 0 1.5 0.3
181
182
183 ACTUAL SPEED SET POINT FOR TEST RPM -120 120 0
184 LOCAL SPEED SET POINT FOR TEST RPM -120 120 0
185 ECR SPEED SET POINT FOR TEST RPM -120 120 0
186 W/H SPEED SET POINT FOR TEST RPM -120 120 0
187
188
189
190 ACTUAL ORDER STOP LEVEL FOR OVER SPEED TEST RPM -120 120 -1
191 ACTUAL ORDER STOP LEVEL FOR OVER SPEED TEST RPM -120 120 1
192
193
194
195
196
197
198
199
S.NO.SN2284 7SH68974-02D 6/39
FOR CONTROL
ADJUSTABLE
TENKEY RANGE
SETTING VALUE
ADDRESS DESCRIPTION UNIT
LOWER UPPER 1 2 3 4
200
201
202
203
204
205
206
207 RPM TEST CANCEL LEVEL RPM 0 10 1
208
209
210
211
212
213
214
215
216
217
218
219 TELEG. TRANS. HARBOR POS. VOLT 0 9.99 9.99
220
221
222 PICK UP NO VOLT DETECT. TIMER RPM 0 10 3
223 DEAD ZONE OF TELEG. TRANS. VOLT 0 0.1 0.05
224 TELEG. TRANS. POS. AS. FULL MAX. VOLT -10 0 -6.69
225 TELEG. TRANS. POS. AS. FULL MAX. E. FULL VOLT -10 0 -6.69
226 TELEG. TRANS. POS. AS. FULL VOLT -10 0 -4.9
227 TELEG. TRANS. POS. AS. HALF VOLT -10 0 -3.69
228 TELEG. TRANS. POS. AS. SLOW VOLT -10 0 -2.45
229 TELEG. TRANS. POS. AS. DEAD SLOW VOLT -10 0 -1.21 -1.16
230 TELEG. TRANS. POS. AS. DEAD SLOW MIN. VOLT -10 0 -0.58 -0.56
231 TELEG. TRANS. POS. AH. DEAD SLOW MIN. VOLT 0 10 0.61
232 TELEG. TRANS. POS. AH. DEAD SLOW VOLT 0 10 1.21 1.23
233 TELEG. TRANS. POS. AH. SLOW VOLT 0 10 2.48 2.54
234 TELEG. TRANS. POS. AH. HALF VOLT 0 10 3.66 3.67
235 TELEG. TRANS. POS. AH. FULL VOLT 0 10 4.91 4.98
236 TELEG. TRANS. POS. NAV. FULL MIN. VOLT 0 10 5.55
237 TELEG. TRANS. POS. N. FULL MAX. VOLT 0 10 9.05
238 TELEG. TRANS. POS. N. FULL MAX. VOLT 0 10 9.05
239
240 DELAYED START (SF) (1:ABN) -
241 AUX. BLOWER FAILURE (SF) (1:ABN) -
242 ACTUAL SPEED (SF) (1:ABN) -
243 ANALOG SIGNAL LINE ALIVE HAND SHAKE (SF) (1:ABN) -
244 DEGITAL SIGNAL LINE ALIVE HAND SHAKE (SF) (1:ABN) -
245 START FAILED (SF) (1:ABN) -
246 REPEATED START (SF) (1:ABN) -
247 PREPARING START (SF) (1:ABN) -
248 START BLOCK (SF) (1:ABN) -
249 ENGINE NOT READY (SF) (1:ABN) -
S.NO.SN2284 7SH68974-02D 7/39
FOR CONTROL
ADJUSTABLE
TENKEY RANGE
SETTING VALUE
ADDRESS DESCRIPTION UNIT
LOWER UPPER 1 2 3 4
250 ENGINE BLOCKED SIGNAL (SF) (1:ABN) -
251 ENGINE READY SIGNAL (SF) (1:ABN) -
252 LOAD LIMITATION SIGNAL (SF) (1:ABN) -
253 LIMITATIONS INCREASED SIGNAL (SF) (1:ABN) -
254 ECR FORCED COMMAND TAKE OVER SIGNAL (SF) (1:ABN) -
255 LOCAL FORCED COMMAND TAKE OVER SIGNAL (SF) (1:ABN) -
256 LOCAL LAMP TEST REQUEST SIGNAL (SF) (1:ABN) -
257 AHEAD COMMAND (SF) (1:ABN) -
258 ASTERN COMMAND SIGNAL (SF) (1:ABN) -
259 ECR CONT. - SELECTED CONTROL STATION SIGNAL (SF) (1:ABN) -
260 LOCAL CONTROL-SELECTED CONTROL STATION SIG. (SF) (1:ABN) -
261 EICU_A ANALOG LINE ALIVE SIGNAL ABNORMAL (1:ABN) -
262 EICU_A DIGITAL LINE ALIVE SIGNAL ABNORMAL (1:ABN) -
263 EICU_A COMMUNICATION ABNORMAL (1:ABN) -
264 EICU_B ANALOG LINE ALIVE SIGNAL ABNORMAL (1:ABN) -
265 EICU_B DIGITAL LINE ALIVE SIGNAL ABNORMAL (1:ABN) -
266 EICU_B COMMUNICATION ABNORMAL (1:ABN) -
267 F/E ALARM REPOSE TIMER SEC. 0.1 10 0.2
268 MAIN START V. BLOCKED (SF) (1:ABN) -
269 T/G ENGAGED (SF) (1:ABN) -
270 LOP (MAIN) COMMUNICATION ABNORMAL (1:ABN) -
271 B/R CONTROL-SELECTED CONT. STATION SIG. (SF) (1:ABN) -
272 RPM ABNORMAL REPOSE TIMER SEC. 0.1 15 10
273
274 LOP (SUB) COMMUNICATION ABNORMAL (1:ABN) -
275 STARTING AIR INPUT COMPENSAT. POINT 0 bar 0 50 0
276 STARTING AIR INPUT COMPENSAT. POINT 1 bar 0 50 20
277 STARTING AIR INPUT COMPENSAT. POINT 2 bar 0 50 40
278 STARTING AIR OUTPUT COMPENSAT. POINT 0 bar 0 50 0
279 STARTING AIR OUTPUT COMPENSAT. POINT 1 bar 0 50 20
280 STARTING AIR OUTPUT COMPENSAT. POINT 2 bar 0 50 40
281 BAR TO VOLT CONVERT RATIO. - 0 50 50
282 CONVERT RATIO. FOR LIMIT OF START AIR - 0 10 10
283 POTENTIO. DISCONNECT. TIMER SEC. 0.1 1 0.5
284 SAFETY CPU ABN. DETECT. TIMER SEC. 0.1 10 0.5
285 REVOLUTION SIGNAL NO VOLT DETECT. TIMER SEC. 0.1 100 30
286
287 POTENTIO. DISCONNECT. RESET TIME LAG SEC. 0.1 10 1.2
288 HANDLE STOP HOLD RESET TIMER SEC. 0.1 1.5 0.8
289 COMMUNICATION ABNORMAL REPOSE TIMER IN POWER ON SEC. 0.2 60 60
290 IMPERFECT B/R (W/H) COND. DETECT TIMER SEC. 0.1 2 0.5
291
292 EICU - RCS COMM. ABNORMAL (1:ABN.) -
293 ENGINE RUN MODE (SF) (1:ABN) -
294 LOCAL SPEED SET POINT (SF) (1:ABN) -
295 ACTUAL SPEED SET POINT (SF) (1:ABN) -
296 BRIDGE SPEED SET POINT (SF) (1:ABN) -
297 ECR SPEED SET POINT (SF) (1:ABN) -
298
299 AMS COMM. ABNORMAL DETECT. TIMER SEC. 0.1 60 15
S.NO.SN2284 7SH68974-02D 8/39
FOR CONTROL
ADJUSTABLE
TENKEY RANGE
SETTING VALUE
ADDRESS DESCRIPTION UNIT
LOWER UPPER 1 2 3 4
300
301
302 BRIDGE SPEED ORDER SIGNAL OF FUNCTION OUTPUT RPM
303 SPEED ORDER SIGNAL RPM
304 REVOLUTION SIGNAL RPM
305 MAIN RPM SIG. FG IN RPM
306 C/R SPEED ORDER SIG. OF FUNC. OUTPUT RPM
307 SPEED ORDER SIGNAL OF LIMITTER OUTPUT RPM
308 SPEED ORDER SIGNAL AFTER TEST RPM SELECTOR RPM
309
310
311 SPEED ORDER SIGNAL AFTER RACING CIRCUIT RPM
312 SPEED ORDER SIGNAL OF TIME SCHEDULE INPUT RPM
313 SPEED ORDER SIGNAL OF TIME SCHEDULE RPM
314 SPEED ORDER SIGNAL OF CRITICAL SPEED JUMP OUTPUT RPM
315 SUB RPM SIGNAL RPM
316 B/R(W/H) SPEED ORDER SIGNAL OF FUNCTION OUTPUT RPM
317
318 ECR SPEED SET. ORDER SIGNAL OF FUNCTION OUTPUT RPM
319 LOCAL SPEED SET. ORDER SIGNAL OF FUNCTION OUTPUT RPM
320 BRIDGE SPEED SET. ORDER SIGNAL OF FUNCTION OUTPUT RPM
321
322
323 SPEED ORDER REVOLUTION SIGNAL AFTER OF ZERO KEEP CIRCUIT RPM
324
325
326 S-CPU V. H. LINE DISCONNECT (MAIN) RPM
327 S-CPU H. LINE DISCONNECT (MAIN) RPM
328 S-CPU V. H. LINE DISCONNECT (SUB) SUB
329 S-CPU H. LINE DISCONNECT (SUB) RPM
330
331 TELEGRAPH TRANSMITTER SIGNAL VOLT
332 TELEGRAPH TRANSMITTER SIGNAL AFTER DISCON, SELECTOR VOLT
333
334 START AIR OUTPUT SIG. FOR BRIDGE CONSOLE VOLT
335 B/R (W/H) HANDLE COMMAND 2 RPM
336 START AIR OUTPUT SIG. FOR C/R CONSOLE VOLT
337 STARTING AIR OUTPUT SIG. VOLT
338 START AIR OUTPUT SIG. FOR PORT WING VOLT
339 START AIR OUTPUT SIG. FOR STBD WING VOLT
340 SPEED ORDER SIGNAL KEEP OUT RPM
341
342
343 MAIN RPM SIG. (NORMAL SPEED MAIN) RPM
344 MAIN RPM SIG. (NORMAL SPEED SUB) RPM
345
346
347
348
349
S.NO.SN2284 7SH68974-02D 9/39
FOR CONTROL
ADJUSTABLE
TENKEY RANGE
SETTING VALUE
ADDRESS DESCRIPTION UNIT
LOWER UPPER 1 2 3 4
350 STARTING AIR FG. OUT SIG. bar
351
352
353
354
355
356 MSV INCLUDE IMPERFECT ALA (1:NOT, 0:IN) - 0 1 1
357
358
359
360 B/R INCR. LIMIT SW. MODE SELECT (1:APPLY ALT FUNC.) - 0 1 1
361 B/R INCR. LIMIT SW. ACTIVE SELECT (1:B/R ONLY) - 0 1 1
362
363 SCHEDULER APPLY SELECT (0:NOT APPLY) - 0 1 0 1
364 LOAD DOWN PROGRAM 2STAGE SELECT (1:2STAGE) - 0 1 1 0
365 KNUCKLE POINT SELECT OF LOAD UP PROG. (1:APPLY) - 0 1 1 0
366
367 B/R SHUT D. CANCEL SW. ACTIVE SELECT. (0:B/R ONLY) - 0 1 0
368
369 C/R SHUT D. CANCEL SW. CONT. POS. SELECT (0:C/R ONLY) - 0 1 1
370 LOCAL SHUT D. CANCEL SW ACTIVE SELECT. (0:LOCAL ONLY) - 0 1 1
371
372
373
374
375
376
377
378
379 ECS ABNORMAL SIGNAL SELECT (0:COMM., 1:HW) - 0 1 0
380
381 TELEG. TRANS. SIG. 1 VOLT
382 TELEG. TRANS. SIG. 2 VOLT
383 TELEGRAPH TRANS. SIG. VOLT
384
385
386
387
388
389
390
391
392
393 LOAD PROGRAM TEST MODE (1:TEST, 0:NORMAL) - 0 1 0
394
395
396
397
398 CONT. POS. BOTH SIG. DETECT. (1:ABN) -
399 CONT. POS. OPEN SIG. DETECT. (1:ABN) -
S.NO.SN2284 7SH68974-02D 10/39
FOR CONTROL
ADJUSTABLE
TENKEY RANGE
SETTING VALUE
ADDRESS DESCRIPTION UNIT
LOWER UPPER 1 2 3 4
400
401
402 MSV C/O INTERLOCK SELECT (1:NOT, 0:IN) - 0 1 1
403 ANALOG SIG. FM ECS TEST RPM 0 1 0
404 CONT. POS. C/O INTERLOCK SELECTION (0:NOT, 1:APPLY AMS COMM. ABN.) - 0 1 0
405 ERC IMPERFECT ALARM (1:NOT, 0:IN) - 0 1 1
406
407
408
409 ERC C/O INTERLOCK SELECT (1:NOT, 0:IN) - 0 1 1
410 RPM SIGNAL SELECT (0:AUTO, 1:SUB, 2:MAIN) - 0 2 0
411 C/R LAMP SELECT AT IMP. ALARM (0:FLICKER, 1:NOT) - 0 1 0
412
413
414
415 START AIR INPUT 1 VOLT 0 9.99 0
416 START AIR INPUT 2 VOLT 0 9.99 4
417 START AIR INPUT 3 VOLT 0 9.99 8
418 START AIR P/W OUTPUT 1 VOLT 0 9.99 1.94
419 START AIR P/W OUTPUT 2 VOLT 0 9.99 5.68
420 START AIR P/W OUTPUT 3 VOLT 0 9.99 9.52
421 START AIR S/W OUTPUT 1 VOLT 0 9.99 1.92
422 START AIR S/W OUTPUT 2 VOLT 0 9.99 5.69
423 START AIR S/W OUTPUT 3 VOLT 0 9.99 9.53
424
425 START AIR C/R OUTPUT 1 VOLT 0 9.99 1.78
426 START AIR C/R OUTPUT 2 VOLT 0 9.99 5.73
427 START AIR C/R OUTPUT 3 VOLT 0 9.99 9.49
428 START AIR B/R OUTPUT 1 VOLT 0 9.99 1.71
429 START AIR B/R OUTPUT 2 VOLT 0 9.99 5.15
430 START AIR B/R OUTPUT 3 VOLT 0 9.99 8.58
431
432 AUTO. OFF CANCEL B/R HANDLE LEVEL VOLT 0 9.99 0.02
433 AUTO. OFF CANCEL SPEED COMMAND RPM 0 120 0.2
434 AUTO. OFF CANCEL C/R HANDLE RPM 0 120 0.2
435
436
437
438 M/E LOAD SIGNAL %
439 M/E LOAD SIGNAL VOLT
440 M/E LOAD SIG. COMPENSAT. VOLT POINT 0 % 0 150 0
441 M/E LOAD SIG. COMPENSAT. VOLT POINT 1 % 0 150 110
442 M/E LOAD SIG. % PONT 0 % 0 150 0
443 M/E LOAD SIG. % PONT 1 % 0 150 110
444 M/E LOAD SIG. 75% % 0 150 75
445 % TO VOLT CONVERT RATIO. - 0 150 110
446 CONVERT RATIO. FOR LIMIT OF FUEL INDEX - 0 10 10
447 DISPLAY AUTO. OFF TIMER (ON SIG. DELAY) SEC. 0.1 5 1
448
449
S.NO.SN2284 7SH68974-02D 11/39
FOR CONTROL
ADJUSTABLE
TENKEY RANGE
SETTING VALUE
ADDRESS DESCRIPTION UNIT
LOWER UPPER 1 2 3 4
500
501 TEST MODE C/O SELECT. (DIGITAL SIGNAL TO EICU) - 0 999 0
502
503
504 TEST MODE OF NO VOLT AT STOP (0:NORMAL, 1:HANDLE STOP) - 0 1 0
505 TEST MODE OF NO VOLT (MAIN) AT STOP (0:NORMAL, 1:MAIN NO VOLT ALARM TEST) - 0 1 0
506 TEST MODE OF NO VOLT (SUB) AT STOP (0:NORMAL, 1:SUB NO VOLT ALARM TEST) - 0 1 0
507
508
509 TEST MODE OF MAIN START V. CONDI. (1:SERVICE) - 0 1 0
510
511
512 LOP LAMP TEST SIGNAL SELECT (0:EICU, 1:LOP) - 0 1 0
513
514
515 TELEG. REC. (C/R) (MAIN) (1:ABN.) -
516 INTERFACE PANEL COMM. ABN. (MAIN) (1:ABN.) -
517 TELEG. REC. (E/S) (SUB) (1:ABN.) -
518 INTERFACE PANEL COMM. ABN. (SUB) (1:ABN.) -
519
520
521
522 SELECTOR FOR INCREASE LIMIT. ON BRIDGE (0:NOT USE, 1:USE) 0 1 1
523
524
525
526 RPM MAIN NO-VOLT (1:NO-VOLT) -
527 RPM SUB NO-VOLT (1:NO-VOLT) -
528 RPM MAIN-SUB DEVIATION HIGH (1: DEVIATION HIGH) -
529
530
531 B/R TELEGRAPH A-IND. SELECT (1: APPLY) - 0 1 1
532 ECR TELEGRAPH A-IND. SELECT (1: APPLY) - 0 1 1
533 FUEL INDEX INPUT 1 VOLT 0 9.99 0
534 FUEL INDEX INPUT 2 VOLT 0 9.99 5
535 FUEL INDEX INPUT 3 VOLT 0 9.99 9.99
536 FUEL INDEX C/R OUTPUT 1 VOLT 0 9.99 2
537 FUEL INDEX C/R OUTPUT 2 VOLT 0 9.99 6
538 FUEL INDEX C/R OUTPUT 3 VOLT 0 9.99 9.99
539 FUEL INDEX C/R OUTPUT 3 VOLT
540
541 DOUT SELECT CTD 7B - 0 8 1
542 DOUT SELECT CTD 81 - 0 8 8
543 DOUT SELECT CTD 83 - 0 8 4
544 DOUT SELECT CTD 85 - 0 8 3
545
546
547
548
549
S.NO.SN2284 7SH68974-02D 12/39
FOR CONTROL
ADJUSTABLE
TENKEY RANGE
SETTING VALUE
ADDRESS DESCRIPTION UNIT
LOWER UPPER 1 2 3 4
550 ANALOG INPUT 1 (NOT USE) -
551 ANALOG INPUT 2 (NOT USE) -
552 ANALOG INPUT 3 (NOT USE) -
553
554
555
556
557
558
559
560 DECIMAL POINT POS. FOR TELEG. TRANSMITTER (0:NO, 1:FIRST, 2:SECOND) - 0 2 0
561 DECIMAL POINT POS. FOR TELEG. RECEIVER (0:NO, 1:FIRST, 2:SECOND) - 0 2 0
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591 SUB RPM HOLD-RESET RPM SET (D.SL. MIN.) RPM 0 120 18
592 SUB RPM HOLD-RESET MAIN/SUB DEVIATION RPM LIMIT RPM 0 120 10
593 SUB RPM HOLD-RESET DELAY TIMER SEC. 0.1 10 3
594 SUB RPM HOLD-ON DELAY TIMER SEC. 0.1 10 3
595 DEVIATION LEVEL FOR DEVIATION ALARM REPOSE RPM 0 150 5
596 KEEP TIMER FOR DEVIATION ALARM SEC. 0.1 60 5
597
598
599
S.NO.SN2284 7SH68974-02D 13/39
FOR CONTROL
ADJUSTABLE
TENKEY RANGE
SETTING VALUE
ADDRESS DESCRIPTION UNIT
LOWER UPPER 1 2 3 4
600
601 10001 ENGINE BLOCKED -
602 10002 (SF) -
603 10003 ENGINE READY -
604 10004 (SF) -
605 10005 ENGINE NOT READY -
606 10006 (SF) -
607 10007 START BLOKED -
608 10008 (SF) -
609 10009 PREPARING START -
610 10010 (SF) -
611 10011 REPEATED START -
612 10012 (SF) -
613 10013 START FAILURE -
614 10014 (SF) -
615 10015 LOAD LIMITATION -
616 10016 (SF) -
617 10017 LIMITATION INCREASE -
618 10018 (SF) -
619 10019 ECR FORCED COMMAND TAKE OVER -
620 10020 (SF) -
621 10021 LOCAL FORCED COMMAND TAKE OVER -
622 10022 (SF) -
623 10023 MAIN STARTING VALVE BLOCKED -
624 10024 (SF) -
625 10025 START AIR DISTRIBUTION SYSTEM BLOKED -
626 10026 (SF) -
627 10027 CONTROL AIR VENTED -
628 10028 (SF) -
629 10029 TURNING GEAR ENGAGED -
630 10030 (SF) -
631 10031 STARTING AIR PRESSURE LOW -
632 10032 (SF) -
633 10033 LOCAL PANEL LAMP TEST REQUEST -
634 10034 (SF) -
635 10035 SG REQUEST -
636 10036 (SF) -
637 10037 SG PERMISSION -
638 10038 (SF) -
639 10039 SG DISCONNECTION FAILED -
640 10040 (SF) -
641 10041 LINE ALIVE HANDSHAKE -
642 10042 (SF) -
643 10043 BRIDGE FORCED COMMAND TAKEOVER (PITCH BACK-UP MODE) -
644 10044 (SF) -
645 10045 ASTERN BACK UP MODE -
646 10046 (SF) -
647 10047 SPARE -
648 10048 (SF) -
649 10049 SLOW COMMAND -
S.NO.SN2284 7SH68974-02D 14/39
FOR CONTROL
ADJUSTABLE
TENKEY RANGE
SETTING VALUE
ADDRESS DESCRIPTION UNIT
LOWER UPPER 1 2 3 4
650 10050 (SF) -
651 10051 ZERO PITCH REQUEST -
652 10052 (SF) -
653 10053 AUX. BLOWER FAILURE -
654 10054 (SF) -
655 10055 DELAYED START -
656 10056 (SF) -
657 10057 AHEAD COMMAND -
658 10058 (SF) -
659 10059 ASTERN COMMAND -
660 10060 (SF) -
661 10061 NEAR LIMIT -
662 10062 (SF) -
663 10063 PITCH NOT IN ZERO POS. DURING START (START BLOCK) -
664 10064 (SF) -
665 10065 BRIDGE CONTROL SELECTED CONTROL STATION -
666 10066 (SF) -
667 10067 ECR CONTROL SELECTED CONTROL STATION -
668 10068 (SF) -
669 10069 LOCAL CONTROL SELECTED CONTROL STATION -
670 10070 (SF) -
671 10071 SPARE -
672 10072 (SF) -
673 10073 TIER III SYSTEM ACTIVATED -
674 10074 (SF) -
675 10075 TIER III NOX REDUCTION ACTIVE -
676 10076 (SF) -
677 10077 PREPARE TIER III FACILITY AVAILABLE -
678 10078 (SF) -
679 10079 PREPARE TIER III SELECTED -
680 10080 (SF) -
681 10081 SPARE -
682 10082 (SF) -
683 10083 SPARE -
684 10084 (SF) -
685 10085 SPARE -
686 10086 (SF) -
687 10087 SPARE -
688 10088 (SF) -
689 10089 SPARE -
690 10090 (SF) -
691 10091 SPARE -
692 10092 (SF) -
693 10093 SPARE -
694 10094 (SF) -
695 10095 SPARE -
696 10096 (SF) -
697 10097 SPARE -
698 10098 (SF) -
699 10099 SPARE -
S.NO.SN2284 7SH68974-02D 15/39
FOR CONTROL
ADJUSTABLE
TENKEY RANGE
SETTING VALUE
ADDRESS DESCRIPTION UNIT
LOWER UPPER 1 2 3 4
700 10100 (SF) -
701 10101 SPARE -
702 10102 (SF) -
703 10103 SPARE -
704 10104 (SF) -
705 10105 SPARE -
706 10106 (SF) -
707 10107 SPARE -
708 10108 (SF) -
709 10109 SPARE -
710 10110 (SF) -
711 10111 SPARE -
712 10112 (SF) -
713 10113 SPARE -
714 10114 (SF) -
715 10115 SPARE -
716 10116 (SF) -
717 10117 SPARE -
718 10118 (SF) -
719 10119 SPARE -
720 10120 (SF) -
721
722
723
724
725
726
727
728
729
730
731 D30001 SF SIGNAL (ACTIVE ENGINE RUNNING MODE) -
732 D30002 SF SIGNAL (SPEED SET POINT FROM LOCAL) -
733 D30003 SF SIGNAL (START AIR PRESS.) -
734 D30004 SF SIGNAL (ACTUAL PITCH (NOT USE)) -
735 D30005 SF SIGNAL (INDEX MARGIN (NOT USE)) -
736 D30006 SF SIGNAL (ACTUAL SPEED SET POINT) -
737 D30007 SET SIGNAL (FUEL INDEX) -
738 D30008 SF SIGNAL (SPEED SET FROM BRIDGE) -
739 D30009 SF SIGNAL (SPEED SET FROM ECR) -
740 D30010 SF SIGNAL (ACTUAL SPEED) -
741 D30011 SF SIGNAL (LINE ALIVE HANDSHAKE) -
742 D30012 SF SIGNAL (SPARE) -
743 D30013 SF SIGNAL (SPARE) -
744 D30014 SF SIGNAL (SPARE) -
745
746
747
748
749
S.NO.SN2284 7SH68974-02D 16/39
FOR CONTROL
ADJUSTABLE
TENKEY RANGE
SETTING VALUE
ADDRESS DESCRIPTION UNIT
LOWER UPPER 1 2 3 4
750
751 W/H SPEED SET (40001) RPM -400 400 0
752 ECR SPEED SET (40002) RPM -400 400 0
753 ACTUAL PITCH SET (40003) % -400 400 0
754 A40004 (SPARE) - -999 999 0
755 A40005 (SPARE) - -999 999 0
756 ENGINE RUN MODE REQ. (40006) - -400 400 0
757 A40007 (SPARE) - -999 999 0
758 A40008 (SPARE) - -999 999 0
759 A40009 (SPARE) - -999 999 0
760 A40010 (SPARE) - -999 999 0
761 A40011 (SPARE) - -999 999 0
762 A40012 (SPARE) - -999 999 0
763 A40013 (SPARE) - -999 999 0
764 A40014 (SPARE) - -999 999 0
765 A40015 (SPARE) - -999 999 0
766 A40016 (SPARE) - -999 999 0
767 A40017 (SPARE) - -999 999 0
768 A40018 (SPARE) - -999 999 0
769 A40019 (SPARE) - -999 999 0
770 A40020 (SPARE) - -999 999 0
771 A40021 (SPARE) - -999 999 0
772 A40022 (SPARE) - -999 999 0
773 A40023 (SPARE) - -999 999 0
774 A40024 (SPARE) - -999 999 0
775 A40025 (SPARE) - -999 999 0
776 A40026 (SPARE) - -999 999 0
777 A40027 (SPARE) - -999 999 0
778 A40028 (SPARE) - -999 999 0
779 A40029 (SPARE) - -999 999 0
780 A40030 (SPARE) - -999 999 0
781 A40031 (SPARE) - -999 999 0
782 A40032 (SPARE) - -999 999 0
783 A40033 (SPARE) - -999 999 0
784 A40034 (SPARE) - -999 999 0
785 A40035 (SPARE) - -999 999 0
786 A40036 (SPARE) - -999 999 0
787 A40037 (SPARE) - -999 999 0
788 A40038 (SPARE) - -999 999 0
789 A40039 (SPARE) - -999 999 0
790 A40040 (SPARE) - 0 1 0
791 A40041 (SPARE) - 1 16383 1
792
793
794
795 A40001 INDICATOR OF SPEED SET FROM BRIDGE RPM
796 A40002 INDICATOR OF SPEED SET FROM ECR (NOT USE) -
797 A40003 INDICATOR OF ACTUAL PITCH SET FROM ECR -
798
799
S.NO.SN2284 7SH68974-02D 17/39
FOR CONTROL
ADJUSTABLE
TENKEY RANGE
SETTING VALUE
ADDRESS DESCRIPTION UNIT
LOWER UPPER 1 2 3 4
800
801 A30001 ACTIVE ENGINE (RUNNING) MODE -
802 A30002 SPEED SET POINT FROM LOCAL RPM
803 A30003 START AIR PRESS. BAR
804 A30004 ACTUAL PITCH (NOT USE) %
805 A30005 INDEX MARGIN (NOT USE) %
806 A30006 ACTUAL SPEED SET POINT RPM
807 A30007 FUEL INDEX %
808 A30008 SPEED SET FROM BRIDGE RPM
809 A30009 SPEED SET FROM ECR RPM
810 A30010 ACTUAL SPEED RPM
811 A30011 LINE ALIVE HANDSHAKE -
812 A30012 (SPARE) -
813 A30013 (SPARE) -
814 A30014 (SPARE) -
815 A30015 FIXED LOAD LIMIT %
816 A30016 ESTIMATED ENGINE POWER %
817 A30017 DUAL FUEL STATUS -
818 A30018 TIER III STATUS -
819 A30019 (SPARE) -
820 A30020 (SPARE) -
821 A30021 (SPARE) -
822 A30022 (SPARE) -
823 A30023 (SPARE) -
824 A30024 (SPARE) -
825 A30025 (SPARE) -
826 A30026 (SPARE) -
827 A30027 (SPARE) -
828 A30028 (SPARE) -
829 A30029 (SPARE) -
830 A30030 (SPARE) -
831 A30031 (SPARE) -
832 A30032 (SPARE) -
833 A30033 (SPARE) -
834 A30034 (SPARE) -
835 A30035 (SPARE) -
836 A30036 (SPARE) -
837 A30037 (SPARE) -
838 A30038 (SPARE) -
839 A30039 (SPARE) -
840 A30040 INTERFACE VERSION NUMBER -
841 A30041 CONFIGURATION NUMBER -
842
843
844
845
846
847
848
849
S.NO.SN2284 7SH68974-02D 18/39
FOR CONTROL
ADJUSTABLE
TENKEY RANGE
SETTING VALUE
ADDRESS DESCRIPTION UNIT
LOWER UPPER 1 2 3 4
850
851 D30001 SF SIGNAL (ACTIVE ENGINE RUNNING MODE) -
852 D30002 SF SIGNAL (SPEED SET POINT FROM LOCAL) -
853 D30003 SF SIGNAL (START AIR PRESS.) -
854 D30004 SF SIGNAL (ACTUAL PITCH (NOT USE)) -
855 D30005 SF SIGNAL (INDEX MARGIN (NOT USE)) -
856 D30006 SF SIGNAL (ACTUAL SPEED SET POINT) -
857 D30007 SET SIGNAL (FUEL INDEX) -
858 D30008 SF SIGNAL (SPEED SET FROM BRIDGE) -
859 D30009 SF SIGNAL (SPEED SET FROM ECR) -
860 D30010 SF SIGNAL (ACTUAL SPEED) -
861 D30011 SF SIGNAL (LINE ALIVE HANDSHAKE) -
862 D30012 SF SIGNAL (SPARE) -
863 D30013 SF SIGNAL (SPARE) -
864 D30014 SF SIGNAL (SPARE) -
865 D30015 SF SIGNAL (FIXED LOAD LIMIT) -
866 D30016 SF SIGNAL (ESTIMATED ENGINE POWER) -
867 D30017 SF SIGNAL (DUAL FUEL STATUS) -
868 D30018 SF SIGNAL (TIER III STATUS) -
869 D30019 SF SIGNAL (SPARE) -
870 D30020 SF SIGNAL (SPARE) -
871 D30021 SF SIGNAL (SPARE) -
872 D30022 SF SIGNAL (SPARE) -
873 D30023 SF SIGNAL (SPARE) -
874 D30024 SF SIGNAL (SPARE) -
875 D30025 SF SIGNAL (SPARE) -
876 D30026 SF SIGNAL (SPARE) -
877 D30027 SF SIGNAL (SPARE) -
878 D30028 SF SIGNAL (SPARE) -
879 D30029 SF SIGNAL (SPARE) -
880 D30030 SF SIGNAL (SPARE) -
881 D30031 SF SIGNAL (SPARE) -
882 D30032 SF SIGNAL (SPARE) -
883 D30033 SF SIGNAL (SPARE) -
884 D30034 SF SIGNAL (SPARE) -
885 D30035 SF SIGNAL (SPARE) -
886 D30036 SF SIGNAL (SPARE) -
887 D30037 SF SIGNAL (SPARE) -
888 D30038 SF SIGNAL (SPARE) -
889 D30039 SF SIGNAL (SPARE) -
890 D30040 SF SIGNAL (SPARE) -
891 D30041 SF SIGNAL (SPARE) -
892
893
894
895
896
897
898
899
S.NO.SN2284 7SH68974-02D 19/39
FOR CONTROL
ADJUSTABLE
TENKEY RANGE
SETTING VALUE
ADDRESS DESCRIPTION UNIT
LOWER UPPER 1 2 3 4
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916 AMS SIGNAL CHECK (DO1-16) -
917 AMS SIGNAL CHECK (DO17-32) -
918 AMS SIGNAL CHECK (DO33-48) -
919 AMS SIGNAL CHECK (DO49-64) -
920 AMS SIGNAL CHECK (DO65-80) -
921 AMS SIGNAL CHECK (DO81-96) -
922
923
924
925
926
927
928
929
930
931 AMS SIGNAL CHECK (DI1-16) -
932 AMS SIGNAL CHECK (DI17-32) -
933 AMS SIGNAL CHECK (DI33-47) -
934 AMS SIGNAL CHECK (AI40001) -
935 AMS SIGNAL CHECK (AI40002) -
936 AMS SIGNAL CHECK (AI40003) -
937
938
939
940 INTERFACE VER. NO. MISMATCH INTERNAL (1: ABNORMAL) -
941 LINE ALIVE (DIGITAL) ABNORMAL EICU_A (1: ABNORMAL) -
942 LINE ALIVE (DIGITAL) ABNORMAL EICU_B (1: ABNORMAL) -
943 LINE ALIVE (ANALOG) ABNORMAL EICU_A (1: ABNORMAL) -
944 LINE ALIVE (ANALOG) ABNORMAL EICU_B (1: ABNORMAL) -
945 INTERFACE VER. NO. MISMATCH EICU_A (1: ABNORMAL) -
946 INTERFACE VER. NO. MISMATCH EICU_B (1: ABNORMAL) -
947 CONFIGURATION NO. MISMATCH EICU_A (1: ABNORMAL) -
948 CONFIGURATION NO. MISMATCH EICU_B (1: ABNORMAL) -
949 INTERFACE VER. NO. (RCS HUB MAIN) -
S.NO.SN2284 7SH68974-02D 20/39
FOR CONTROL
ADJUSTABLE
TENKEY RANGE
SETTING VALUE
ADDRESS DESCRIPTION UNIT
LOWER UPPER 1 2 3 4
950 INTERFACE VER. NO. (RCS HUB SUB) -
951
952
953
954
955
956
957
958
959
960
961 ECS SIGNAL CHECK (DI10001-10012) -
962 ECS SIGNAL CHECK (DI10013-10024) -
963 ECS SIGNAL CHECK (DI10025-10036) -
964 ECS SIGNAL CHECK (DI10037-10048) -
965 ECS SIGNAL CHECK (DI10049-10060) -
966 ECS SIGNAL CHECK (DI10061-10072) -
967 ECS SIGNAL CHECK (DI10073-10084) -
968 ECS SIGNAL CHECK (DI10085-10096) -
969 ECS SIGNAL CHECK (DI10097-10108) -
970 ECS SIGNAL CHECK (DI10109-10120) -
971 ECS SIGNAL CHECK (AI(SF)30001-30012) -
972 ECS SIGNAL CHECK (AI(SF)30013-30024) -
973 ECS SIGNAL CHECK (AI(SF)30025-30036) -
974 ECS SIGNAL CHECK (AI(SF)30037-30041) -
975 ECS SIGNAL CHECK (DO1-12) -
976 ECS SIGNAL CHECK (DO13-24) -
977 ECS SIGNAL CHECK (DO25-36) -
978 ECS SIGNAL CHECK (DO37-48) -
979 ECS SIGNAL CHECK (DO49-60) -
980 ECS SIGNAL CHECK (DO61-72) -
981 ECS SIGNAL CHECK (DO73-84) -
982 ECS SIGNAL CHECK (DO85-96) -
983 ECS SIGNAL CHECK (AO(SF)40001-40012) -
984 ECS SIGNAL CHECK (AO(SF)40013-40024) -
985 ECS SIGNAL CHECK (AO(SF)40025-40036) -
986 ECS SIGNAL CHECK (AO(SF)40037-40041&DUMMY OUT) -
987
988
989
990
991
992
993
994
995
996
997
998
999
S.NO.SN2284 7SH68974-02D 21/39
FOR SAFETY
ADJUSTABLE
TENKEY RANGE
SETTING VALUE
ADDRESS DESCRIPTION UNIT
LOWER UPPER 1 2 3 4
000
001
002
003 AHEAD REVOLUTION DETECT RPM 0 30 10
004 ASTERN REVOLUTION DETECT. RPM -30 0 -10
005 OVER SPEED DETECT. RPM 0 120 86.1
006 CRITICAL SPEED ALARM LOW ZONE LOWER LEVEL RPM 0 120 120 37.5
007 CRITICAL SPEED ALARM LOW ZONE UPPER LEVEL RPM 0 120 120 46
008 CRITICAL SPEED ALARM HIGH ZONE LOWER LEVEL RPM 0 120 120
009 CRITICAL SPEED ALARM HIGH ZONE UPPER LEVEL RPM 0 120 120
010 ALARM REPOSE LEVEL 1 SCAV. AIR BOX FIRE RPM 0 120 120
011 ALARM REPOSE LEVEL 2 M/E EXH. GAS H.D. RPM 0 120 120
012 ALARM REPOSE LEVEL 3 PISTON C.O. NON-FLOW RPM 0 120 120
013 ALARM REPOSE LEVEL 4 ASTERN DETECT. RPM -120 120 -10
014 M/E RUN SIG. FOR AUTO. SLOW DOWN LEVEL RPM 0 120 0
015 M/E RUN DETECT. FOR LOGGER RPM 0 120 10
016 ALARM REPOSE (FOR AMS) RPM 0 120 15
017 OVER SPEED PREALARM RPM 0 120 86
018
019 M/E RUN LEVEL FOR DETECT. FUNC. RPM 0 120 10
020 CRITICAL SPEED ALARM REPOSE DETECT LEVEL % 0 120 5
021 ALARM REPOSE LEVEL 5 AXIAL VIBRATION HIGH RPM -120 120 120
022
023
024
025 OVER SPEED TIMER SEC. 0.1 0.2 0.1
026
027
028
029
030
031 SH-1 (FOR SHUT DOWN (TRIP)) SEC. 0.1 10 0.1
032 SH-2 (FOR SHUT DOWN (TRIP)) SEC. 0.1 10 0.1
033 SH-3 (FOR SHUT DOWN (TRIP)) SEC. 0.1 10 0.1
034 SH-4 (FOR SHUT DOWN (TRIP)) SEC. 0.1 10 0.1
035 SH-5 (FOR SHUT DOWN (TRIP)) SEC. 0.1 10 0.1
036 SH-6 (FOR SHUT DOWN (TRIP)) SEC. 0.1 10 0.1
037 SH-7 (FOR SHUT DOWN (TRIP)) SEC. 0.1 10 0.1
038 SH-8 (FOR SHUT DOWN (TRIP)) SEC. 0.1 10 0.1
039 SH-9 (FOR SHUT DOWN (TRIP)) SEC. 0.1 10 0.1
040 SH-10 (FOR SHUT DOWN (TRIP)) SEC. 0.1 10 0.1
041 SH-1 (FOR SHUT DOWN) SEC. 0.1 20 6
042 SH-2 (FOR SHUT DOWN) SEC. 0.1 20 0.1
043 SH-3 (FOR SHUT DOWN) SEC. 0.1 20 0.1
044 SH-4 (FOR SHUT DOWN) SEC. 0.1 20 6
045 SH-5 (FOR SHUT DOWN) SEC. 0.1 20 6
046 SH-6 (FOR SHUT DOWN) SEC. 0.1 20 6
047 SH-7 (FOR SHUT DOWN) SEC. 0.1 20 6
048 SH-8 (FOR SHUT DOWN) SEC. 0.1 20 6
049 SH-9 (FOR SHUT DOWN) SEC. 0.1 20 6
S.NO.SN2284 7SH68974-02D 22/39
FOR SAFETY
ADJUSTABLE
TENKEY RANGE
SETTING VALUE
ADDRESS DESCRIPTION UNIT
LOWER UPPER 1 2 3 4
050 SH-10 (FOR SHUT DOWN) SEC. 0.1 20 6
051 SL-1 (FOR SLOW DOWN) SEC. 0.1 10 0.1
052 SL-2 (FOR SLOW DOWN) SEC. 0.1 10 0.1
053 SL-3 (FOR SLOW DOWN) SEC. 0.1 10 0.1
054 SL-4 (FOR SLOW DOWN) SEC. 0.1 10 0.1
055 SL-5 (FOR SLOW DOWN) SEC. 0.1 10 0.1
056 SL-6 (FOR SLOW DOWN) SEC. 0.1 10 0.1
057 SL-7 (FOR SLOW DOWN) SEC. 0.1 10 0.1
058 SL-8 (FOR SLOW DOWN) SEC. 0.1 10 0.1
059 SL-9 (FOR SLOW DOWN) SEC. 0.1 10 0.1
060 SL-10 (FOR SLOW DOWN) SEC. 0.1 10 0.1
061 SL-11 (FOR SLOW DOWN) SEC. 0.1 10 0.1
062 SL-12 (FOR SLOW DOWN) SEC. 0.1 10 0.1
063 SL-13 (FOR SLOW DOWN) SEC. 0.1 10 0.1
064 SL-14 (FOR SLOW DOWN) SEC. 0.1 10 0.1
065 SL-15 (FOR SLOW DOWN) SEC. 0.1 10 0.1
066 SL-16 (FOR SLOW DOWN) SEC. 0.1 10 0.1
067 SL-17 (FOR SLOW DOWN) SEC. 0.1 10 0.1
068 SL-18 (FOR SLOW DOWN) SEC. 0.1 10 0.1
069 SL-19 (FOR SLOW DOWN) SEC. 0.1 10 0.1
070 SL-20 (FOR SLOW DOWN) SEC. 0.1 10 0.1
071 SL-21 (FOR SLOW DOWN) SEC. 0.1 10 0.1
072 SL-22 (FOR SLOW DOWN) SEC. 0.1 10 0.1
073 SL-23 (FOR SLOW DOWN) SEC. 0.1 10 0.1
074 SL-24 (FOR SLOW DOWN) SEC. 0.1 10 0.1
075 SL-1 (FOR SLOW DOWN) SEC. 0.1 60 6
076 SL-2 (FOR SLOW DOWN) SEC. 0.1 60 6
077 SL-3 (FOR SLOW DOWN) SEC. 0.1 60 6
078 SL-4 (FOR SLOW DOWN) SEC. 0.1 60 6
079 SL-5 (FOR SLOW DOWN) SEC. 0.1 60 6
080 SL-6 (FOR SLOW DOWN) SEC. 0.1 60 6
081 SL-7 (FOR SLOW DOWN) SEC. 0.1 60 6
082 SL-8 (FOR SLOW DOWN) SEC. 0.1 60 6
083 SL-9 (FOR SLOW DOWN) SEC. 0.1 60 6
084 SL-10 (FOR SLOW DOWN) SEC. 0.1 60 6
085 SL-11 (FOR SLOW DOWN) SEC. 0.1 60 6
086 SL-12 (FOR SLOW DOWN) SEC. 0.1 60 6
087 SL-13 (FOR SLOW DOWN) SEC. 0.1 60 6
088 SL-14 (FOR SLOW DOWN) SEC. 0.1 60 6
089 SL-15 (FOR SLOW DOWN) SEC. 0.1 60 6
090 SL-16 (FOR SLOW DOWN) SEC. 0.1 60 6
091 SL-17 (FOR SLOW DOWN) SEC. 0.1 60 6
092 SL-18 (FOR SLOW DOWN) SEC. 0.1 60 6
093 SL-19 (FOR SLOW DOWN) SEC. 0.1 60 6
094 SL-20 (FOR SLOW DOWN) SEC. 0.1 60 6
095 SL-21 (FOR SLOW DOWN) SEC. 0.1 60 6
096 SL-22 (FOR SLOW DOWN) SEC. 0.1 60 6
097 SL-23 (FOR SLOW DOWN) SEC. 0.1 60 6
098 SL-24 (FOR SLOW DOWN) SEC. 0.1 60 6
099
S.NO.SN2284 7SH68974-02D 23/39
FOR SAFETY
ADJUSTABLE
TENKEY RANGE
SETTING VALUE
ADDRESS DESCRIPTION UNIT
LOWER UPPER 1 2 3 4
100 CRITICAL SPEED ALARM TIMER SEC. 0.1 60 30 60
101 WRONG WAY ALARM TIMER SEC 0.1 30 5 3
102 SLOW DOWN REQUEST ALARM TIMER SEC. 0.1 1 0.5
103
104
105
106 ALARM CANCEL TIMER FOR ASTERN DETECT SEC. 0.1 999 0.1
107
108 ALARM CANCEL TIMER SEC. 0.1 999 1
109 RPM SIGNAL DEVIATION ABNORMAL DETECT TIMER SEC. 0.1 5 3
110 TIMER FOR FUEL CUT OFF SOL. VALVE - 1 60 30
111 UNIT OF TIMER ST110 (1:SEC. 60:MIN.) SEC. 1 600 60
112
113
114
115
116
117
118
119
120 TELEG. TRANS. AHEAD SLOW DOWN RESET LEVEL VOLT 0 10 3.066
121 TELEG. TRANS. ASTERN SLOW DOWN RESET LEVEL VOLT -10 0 -3.072
122 TELEG. RECIVER AHEAD SLOW DOWN RESET LEVEL VOLT 0 10 3.062
123 TELEG. RECIVER ASTERN SLOW DOWN RESET LEVEL VOLT -10 0 -3.028
124
125 FI=0 DETECT LEVEL FOR OVER SPEED % -5 150 5
126
127
128
129 RPM SIGNAL DEV. DETECT LEVEL RPM 0 10 10
130 FUEL INDEX ZERO DETECT. FOR REPOSE FUNCTION % 0 50 5
131
132 SL-25 (FOR SLOW DOWN) SEC. 0.1 10 0.1
133 SL-26 (FOR SLOW DOWN) SEC. 0.1 10 0.1
134 SL-27 (FOR SLOW DOWN) SEC. 0.1 10 0.1
135 SL-28 (FOR SLOW DOWN) SEC. 0.1 10 0.1
136 SL-29 (FOR SLOW DOWN) SEC. 0.1 10 0.1
137 SL-30 (FOR SLOW DOWN) SEC. 0.1 10 0.1
138 SL-31 (FOR SLOW DOWN) SEC. 0.1 10 0.1
139 SL-32 (FOR SLOW DOWN) SEC. 0.1 10 0.1
140 SL-25 (FOR SLOW DOWN) SEC. 0.1 60 6
141 SL-26 (FOR SLOW DOWN) SEC. 0.1 60 6
142 SL-27 (FOR SLOW DOWN) SEC. 0.1 60 6
143 SL-28 (FOR SLOW DOWN) SEC. 0.1 60 6
144 SL-29 (FOR SLOW DOWN) SEC. 0.1 60 6
145 SL-30 (FOR SLOW DOWN) SEC. 0.1 60 6
146 SL-31 (FOR SLOW DOWN) SEC. 0.1 60 6
147 SL-32 (FOR SLOW DOWN) SEC. 0.1 60 6
148
149
S.NO.SN2284 7SH68974-02D 24/39
FOR SAFETY
ADJUSTABLE
TENKEY RANGE
SETTING VALUE
ADDRESS DESCRIPTION UNIT
LOWER UPPER 1 2 3 4
150
151
152
153
154
155 PULSE WIDTH FOR DATA REQUEST SIGNAL (ON) TO AMS SEC. 0.1 999 9
156 PULSE WIDTH FOR DATA REQUEST SIGNAL (OFF) TO AMS SEC. 0.1 999 300
157
158 RPM SIGNAL FOR AMS OFFSET RPM -999 999 400
159
160 REVOLUTION SIGNAL ASTERN MAX. RPM -120 120 -120
161 REVOLUTION SIGNAL STOP CONDITION RPM -120 120 0
162 REVOLUTION SIGNAL AHEAD MAX. RPM -120 120 120
163 REVOLUTION SIGNAL ASTERN MAX. RPM -120 120 -120
164 REVOLUTION SIGNAL STOP CONDITION RPM -120 120 0
165 REVOLUTION SIGNAL AHEAD MAX. RPM -120 120 120
166 REVOLUTION SIGNAL ASTERN MAX. FOR CTB (HARD WIRE) RPM -120 120 -120
167 REVOLUTION SIGNAL STOP CONDITION FOR CTB (HARD WIRE) RPM -120 120 0
168 REVOLUTION SIGNAL AHEAD MAX. FOR CTB (HARD WIRE) RPM -120 120 120
169 REVOLUTION SIGNAL ASTERN MAX. FOR CTB (HARD WIRE) VOLT -10 10 1.9
170 REVOLUTION SIGNAL STOP CONDITION FOR CTB (HARD WIRE) VOLT -10 10 5.71
171 REVOLUTION SIGNAL AHEAD MAX. FOR CTB (HARD WIRE) VOLT -10 10 9.52
172
173
174
175
176
177
178 REVOLUTION SIGNAL SET FOR AMS - 0 10 1
179
180 HYSTERESYS RPM 0 10 1
181 SAFETY REV. SIGNAL ABNORMAL CANCEL LEVEL RPM 0 120 10
182
183 M/E RUN LEVEL DETECT FOR SOOT BLR RPM 0 120 30
184
185 OVER SPEED TEST CANCEL LEVEL RPM 0 120 1
186
187
188
189
190
191
192
193
194
195
196
197
198
199
S.NO.SN2284 7SH68974-02D 25/39
FOR SAFETY
ADJUSTABLE
TENKEY RANGE
SETTING VALUE
ADDRESS DESCRIPTION UNIT
LOWER UPPER 1 2 3 4
200
201
202
203
204
205
206
207 RPM TEST CANCEL LEVEL RPM 0 10 1
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222 PICK UP NO-VOLT DETECT. LEVEL RPM 0 10 1
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
S.NO.SN2284 7SH68974-02D 26/39
FOR SAFETY
ADJUSTABLE
TENKEY RANGE
SETTING VALUE
ADDRESS DESCRIPTION UNIT
LOWER UPPER 1 2 3 4
250
251
252
253
254 ECR FORCED COMMAND TAKE OVER SIGNAL (SF)(1:ABN) -
255 LOCAL FORCED COMMAND TAKE OVER SIGNAL (SF)(1:ABN) -
256 LOCAL LAMP TEST REQUEST SIGNAL (SF)(1:ABN) -
257 AHEAD COMMAND (SF) -
258 ASTERN COMMAND SIGNAL (SF)(1:ABN) -
259 ECR CONTROL-SELECTED CONTROL STATION SIGNAL (SF)(1:ABN) -
260 LOCAL CONT. - SELECTED CONT. STATION SIG. (SF)(1:ABN) -
261 EICU_A ANALOG LINE ALIVE SIGNAL ABNORMAL -
262 EICU_A DIGITAL LINE ALIVE SIGNAL ABNORMAL -
263 EICU_A COMMUNICATION ABNORMAL -
264 EICU_B ANALOG LINE ALIVE SIGNAL ABNORMAL -
265 EICU_B DIGITAL LINE ALIVE SIGNAL ABNORMAL -
266 EICU_B COMM. ABNORMAL -
267
268 W/H CONT. - SELECTED CONT. STATION SIG. (SF)(1:ABN) -
269
270
271
272 SENSOR DISCONNECT. SEC. 0.1 1 0.5
273
274
275
276
277
278 RPM ABNORMAL REPOSE TIMER SEC. 0.1 15 10
279 OVER SPEED ALARM TIMER SEC. 0.1 1 0.5
280
281
282 M/E STOP DETECT. TIMER (FOR LOGGER) SEC 0.1 30 0.5
283
284 SLOW DOWN RESET TIMER SEC 0.1 1 0.2
285 REVOLUTION SIGNAL NO-VOLT DETECT. TIMER SEC. 0.1 100 30
286 TELEG. POTENTIO. ABNORMAL TIMER SEC. 0.1 5 1
287
288
289 COMMUNICATION ABNORMAL REPOSE TIMER SEC. 0.1 60 60
290 LOP (MAIN) COMMUNICATION ABNORMAL (1:ABN.) -
291 LOP (SUB) COMMUNICATION ABNORMAL (1:ABN.) -
292 CAUSE RESET FOR RPM MONITOR (POPUP) KEEP TIMER SEC. 0.1 10 5
293
294
295
296
297
298
299 AMS COMM. ABNORMAL DETECT. TIMER SEC. 0.1 60 15
S.NO.SN2284 7SH68974-02D 27/39
FOR SAFETY
ADJUSTABLE
TENKEY RANGE
SETTING VALUE
ADDRESS DESCRIPTION UNIT
LOWER UPPER 1 2 3 4
300
301
302 REVOLUTION SIGNAL FOR AMS RPM
303
304 REVOLUTION SIGNAL RPM
305 MAIN RPM SIG. FG IN RPM
306 TELEG. TRANS. INPUT VOLT
307 TELEG. RECEIVER INPUT VOLT
308
309 REVOLUTION SIGNAL FOR CTB (HARD WIRE) RPM
310
311 SL-1 ACTIVE INDICATOR -
312 SL-2 ACTIVE INDICATOR -
313 SL-3 ACTIVE INDICATOR -
314 SL-4 ACTIVE INDICATOR -
315 SL-5 ACTIVE INDICATOR -
316 SL-6 ACTIVE INDICATOR -
317 SL-7 ACTIVE INDICATOR -
318 SL-8 ACTIVE INDICATOR -
319 SL-9 ACTIVE INDICATOR -
320 SL-10 ACTIVE INDICATOR -
321 SL-11 ACTIVE INDICATOR -
322 SL-12 ACTIVE INDICATOR -
323 SL-13 ACTIVE INDICATOR -
324 SL-14 ACTIVE INDICATOR -
325 SL-15 ACTIVE INDICATOR -
326 SL-16 ACTIVE INDICATOR -
327 SL-17 ACTIVE INDICATOR -
328 SL-18 ACTIVE INDICATOR -
329 SL-19 ACTIVE INDICATOR -
330 SL-20 ACTIVE INDICATOR -
331 SL-21 ACTIVE INDICATOR -
332 SL-22 ACTIVE INDICATOR -
333 SL-23 ACTIVE INDICATOR -
334 SL-24 ACTIVE INDICATOR -
335
336
337
338 RPM SIGNAL (SUB) FOR OVER SPEED REPOSE RPM
339
340
341
342
343 RPM SIGNAL IN (NORMAL SPEED MAIN) RPM
344 RPM SIGNAL IN (NORMAL SPEED SUB) RPM
345 C-CPU VERY H. LINE (MAIN) DISCONNECT (1:DISCONNECT) -
346 C-CPU H. LINE (MAIN) (1:DISCONNECT) -
347 S-CPU VERY H. LINE (SUB) DISCONNECT (1:DISCONNECT) -
348 S-CPU H. LINE (SUB) (1:DISCONNECT) -
349
S.NO.SN2284 7SH68974-02D 28/39
FOR SAFETY
ADJUSTABLE
TENKEY RANGE
SETTING VALUE
ADDRESS DESCRIPTION UNIT
LOWER UPPER 1 2 3 4
350 RPM SIG. OF INDICATOR C/O (0:MAIN, 1:SUB) - 0 1 0
351 INDIVIDUAL CANCEL OVERRIDE SELECT (0:NOT, 1:USE) - 0 1 0
352
353 SHUT DOWN SIGNAL FOR EICU_B (WHRS) SELECTION (0:NORMAL 1:NOT CANCEL) - 0 1 1
354 ASTERN SIGNAL SELECT (0:M/E, 1;TELEG.) - 0 1 1
355 TEST MODE FOR WRONG WAY & S/D ALARM (1:TEST) - 0 1 0
356 MT AH/AS SIGNAL AT TEST MODE (0:AH, 1:AS) - 0 1 0
357 SHUT DOWN CANCEL SIGNAL SELECT (1: STD, 0: HHI) - 0 1 0
358 SLOW DOWN REQUEST SIG. SELECT ACTIVE AT (1:LESS THAN D.S., 0:STD.) - 0 1 0
359 CONT. POS. SELECT FOR E/S SHUT DOWN SW. (1:ANYTIME) - 0 1 1
360
361
362
363 CONT. POS. SELECT FOR B/R SHUT/SLOW D. CANCEL SW. (0:B/R ONLY) - 0 1 0
364
365 CONT. POS. SELECT FOR C/R SHUT/SLOW D. CANCEL SW. (1:ANYTIME) - 0 1 1
366
367 PREWARNING SIG. SELECT (1:CANCELABLE ONLY) - 0 1 1
368
369
370
371
372 ACTIVE DIREC. SELECT. FOR SLOW DOWN (1:AH ONLY) - 0 1 0
373 SOUND SIG. SELECT AT WRONG WAY - 0 1 1
374 E/S SLOW DOWN APPLY SELECT (0:APPLY, 1:NOT) - 0 1 0
375
376
377 SIGNAL REPOSE SELECT FOR AXIAL VIBRATION H. (1:NOT CANCEL) - 0 1 1
378 SIGNAL REPOSE SELECT FOR SCAV. AIR BOX FIRE (1:NOT CANCEL) - 0 1 1
379 SIGNAL REPOSE SELECT FOR EXH. GASH.D. (1:NOT CANCEL) - 0 1 1
380 SIGNAL REPOSE SELECT FOR PISTON C.O. NON-FLOW (1:NOT REPOSE) - 0 1 1
381 AUTO. EMERG. SHUT DOWN (TRIP) CANCEL SELECT (SH-1) (1:CANCEL) - 0 1 0
382 AUTO. EMERG. SHUT DOWN (TRIP) CANCEL SELECT (SH-2) (1:CANCEL) - 0 1 0
383 AUTO. EMERG. SHUT DOWN (TRIP) CANCEL SELECT (SH-3) (1:CANCEL) - 0 1 0
384 AUTO. EMERG. SHUT DOWN (TRIP) CANCEL SELECT (SH-4) (1:CANCEL) - 0 1 1
385 AUTO. EMERG. SHUT DOWN (TRIP) CANCEL SELECT (SH-5) (1:CANCEL) - 0 1 1
386 AUTO. EMERG. SHUT DOWN (TRIP) CANCEL SELECT (SH-6) (1:CANCEL) - 0 1 1
387 AUTO. EMERG. SHUT DOWN (TRIP) CANCEL SELECT (SH-7) (1:CANCEL) - 0 1 1
388 AUTO. EMERG. SHUT DOWN (TRIP) CANCEL SELECT (SH-8) (1:CANCEL) - 0 1 1
389 AUTO. EMERG. SHUT DOWN (TRIP) CANCEL SELECT (SH-9) (1:CANCEL) - 0 1 1
390 AUTO. EMERG. SHUT DOWN (TRIP) CANCEL SELECT (SH-10) (1:CANCEL) - 0 1 1
391
392
393
394
395
396
397
398
399
S.NO.SN2284 7SH68974-02D 29/39
FOR SAFETY
ADJUSTABLE
TENKEY RANGE
SETTING VALUE
ADDRESS DESCRIPTION UNIT
LOWER UPPER 1 2 3 4
400 FOR MAINTENANCE (E/S CONT.) - 0 1 0
401 FOR MAINTENANCE (C/R CONT.) - 0 1 0
402 NUMBER OF SHUT DOWN - 0 10 7
403 NUMBER OF SLOW DOWN - 0 32 23
404
405
406
407
408
409
410 RPM SIGNAL SELECT (0:AUTO, 1:SUB, 2:MAIN) - 0 2 0
411
412
413
414
415
416 SL-16 COMMON SLD FOR BACKUP SELECT (0: ACTIVE AT AMS COMM. ABN. ONLY, 1: NORMAL SLD) - 0 1 0
417
418
419
420 WING SHUT DOWN P.B. DISCON (1:PW 2:SW) -
421 AUTO SLOW DOWN OVERRIDE SELECT (SL-1) (NOT:0, OVERRIDE:1) - 0 1 1
422 AUTO SLOW DOWN OVERRIDE SELECT (SL-2) (NOT:0, OVERRIDE:1) - 0 1 1
423 AUTO SLOW DOWN OVERRIDE SELECT (SL-3) (NOT:0, OVERRIDE:1) - 0 1 1
424 AUTO SLOW DOWN OVERRIDE SELECT (SL-4) (NOT:0, OVERRIDE:1) - 0 1 1
425 AUTO SLOW DOWN OVERRIDE SELECT (SL-5) (NOT:0, OVERRIDE:1) - 0 1 1
426 AUTO SLOW DOWN OVERRIDE SELECT (SL-6) (NOT:0, OVERRIDE:1) - 0 1 1
427 AUTO SLOW DOWN OVERRIDE SELECT (SL-7) (NOT:0, OVERRIDE:1) - 0 1 1
428 AUTO SLOW DOWN OVERRIDE SELECT (SL-8) (NOT:0, OVERRIDE:1) - 0 1 1
429 AUTO SLOW DOWN OVERRIDE SELECT (SL-9) (NOT:0, OVERRIDE:1) - 0 1 1
430 AUTO SLOW DOWN OVERRIDE SELECT (SL-10) (NOT:0, OVERRIDE:1) - 0 1 1
431 AUTO SLOW DOWN OVERRIDE SELECT (SL-11) (NOT:0, OVERRIDE:1) - 0 1 1
432 AUTO SLOW DOWN OVERRIDE SELECT (SL-12) (NOT:0, OVERRIDE:1) - 0 1 1
433 AUTO SLOW DOWN OVERRIDE SELECT (SL-13) (NOT:0, OVERRIDE:1) - 0 1 1
434 AUTO SLOW DOWN OVERRIDE SELECT (SL-14) (NOT:0, OVERRIDE:1) - 0 1 1
435 AUTO SLOW DOWN OVERRIDE SELECT (SL-15) (NOT:0, OVERRIDE:1) - 0 1 1
436 AUTO SLOW DOWN OVERRIDE SELECT (SL-16) (NOT:0, OVERRIDE:1) - 0 1 1
437 AUTO SLOW DOWN OVERRIDE SELECT (SL-17) (NOT:0, OVERRIDE:1) - 0 1 1
438 AUTO SLOW DOWN OVERRIDE SELECT (SL-18) (NOT:0, OVERRIDE:1) - 0 1 1
439 AUTO SLOW DOWN OVERRIDE SELECT (SL-19) (NOT:0, OVERRIDE:1) - 0 1 1
440 AUTO SLOW DOWN OVERRIDE SELECT (SL-20) (NOT:0, OVERRIDE:1) - 0 1 1
441 AUTO SLOW DOWN OVERRIDE SELECT (SL-21) (NOT:0, OVERRIDE:1) - 0 1 1
442 AUTO SLOW DOWN OVERRIDE SELECT (SL-22) (NOT:0, OVERRIDE:1) - 0 1 1
443 AUTO SLOW DOWN OVERRIDE SELECT (SL-23) (NOT:0, OVERRIDE:1) - 0 1 1
444 AUTO SLOW DOWN OVERRIDE SELECT (SL-24) (NOT:0, OVERRIDE:1) - 0 1 1
445
446
447 DISPLAY AUTO. OFF TIMER (ON SIG. DELAY) SEC. 0.1 5 1
448 SELECTOR FOR CANCEL ALARM (1:INCLUDE INDIVIDUAL SHUT/SLOW DOWN TO CANCEL ALARM) - 0 1 1
449
S.NO.SN2284 7SH68974-02D 30/39
FOR SAFETY
ADJUSTABLE
TENKEY RANGE
SETTING VALUE
ADDRESS DESCRIPTION UNIT
LOWER UPPER 1 2 3 4
500 BRIDGE UNIT NOT INSTALED SELECT TEST MODE - 0 999 0
501
502
503
504 TEST MODE OF NO-VOLT AT STOP CONDITION (0:NORMAL, 1:HANDLE STOP "ON") - 0 1 0
505 TEST MODE OF NO-VOLT (MAIN) AT STOP CONDITION (0:NORMAL, 1:MAIN NO-VOLT ALARM HAPPEN) - 0 1 0
506 TEST MODE OF NO-VOLT (SUB) AT STOP CONDITION (0:NORMAL, 1:MAIN NO-VOLT ALARM HAPPEN) - 0 1 0
507
508
509
510
511
512 LOP LAMP TEST SIGNAL SELECT (0:EICU, 1:LOP) - 0 1 0
513
514
515 TELEG. REC. (C/R) COMM. ABN. (MAIN) (1:ABN.) -
516 INTERFACE PANEL COMM. ABN. (MAIN) (1:ABN.) -
517 TELEG. REC. (E/S) COMM. ABN. (SUB) (1:ABN.) -
518 INTERFACE PANEL COMM. ABN. (SUB) (1:ABN.) -
519
520
521
522
523
524
525
526 RPM MAIN NO-VOLT (1:NO-VOLT) -
527 RPM SUB NO-VOLT (1:NO-VOLT) -
528 RPM MAIN-SUB DEVIATION HIGH (1: DEVIATION HIGH) -
529
530 AUTO SLOW DOWN OVERRIDE SELECT (SL-25) (NOT:0, OVERRIDE:1) - 0 1 1
531 AUTO SLOW DOWN OVERRIDE SELECT (SL-26) (NOT:0, OVERRIDE:1) - 0 1 1
532 AUTO SLOW DOWN OVERRIDE SELECT (SL-27) (NOT:0, OVERRIDE:1) - 0 1 1
533 AUTO SLOW DOWN OVERRIDE SELECT (SL-28) (NOT:0, OVERRIDE:1) - 0 1 1
534 AUTO SLOW DOWN OVERRIDE SELECT (SL-29) (NOT:0, OVERRIDE:1) - 0 1 1
535 AUTO SLOW DOWN OVERRIDE SELECT (SL-30) (NOT:0, OVERRIDE:1) - 0 1 1
536 AUTO SLOW DOWN OVERRIDE SELECT (SL-31) (NOT:0, OVERRIDE:1) - 0 1 1
537 AUTO SLOW DOWN OVERRIDE SELECT (SL-32) (NOT:0, OVERRIDE:1) - 0 1 1
538 SL-25 ACTIVE INDICATOR -
539 SL-26 ACTIVE INDICATOR -
540 SL-27 ACTIVE INDICATOR -
541 SL-28 ACTIVE INDICATOR -
542 SL-29 ACTIVE INDICATOR -
543 SL-30 ACTIVE INDICATOR -
544 SL-31 ACTIVE INDICATOR -
545 SL-32 ACTIVE INDICATOR -
546
547
548
549
S.NO.SN2284 7SH68974-02D 31/39
FOR SAFETY
ADJUSTABLE
TENKEY RANGE
SETTING VALUE
ADDRESS DESCRIPTION UNIT
LOWER UPPER 1 2 3 4
550 ANALOG INPUT 1 (NOT USE) -
551 ANALOG INPUT 2 (NOT USE) -
552 ANALOG INPUT 3 (NOT USE) -
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591 SUB RPM HOLD-RESET RPM SET (D.SL. MIN.) RPM 0 120 18
592 SUB RPM HOLD-RESET MAIN/SUB DEVIATION RPM LIMIT RPM 0 120 10
593 SUB RPM HOLD-RESET DELAY TIMER SEC. 0.1 10 3
594 SUB RPM HOLD-ON DELAY TIMER SEC. 0.1 10 3
595 DEVIATION LEVEL FOR DEVIATION ALARM REPOSE RPM 0 150 5
596 KEEP TIMER FOR DEVIATION ALARM SEC. 0.1 60 5
597
598
599
S.NO.SN2284 7SH68974-02D 32/39
FOR SAFETY
ADJUSTABLE
TENKEY RANGE
SETTING VALUE
ADDRESS DESCRIPTION UNIT
LOWER UPPER 1 2 3 4
600
601 10001 ENGINE BLOCKED -
602 10002 (SF) -
603 10003 ENGINE READY -
604 10004 (SF) -
605 10005 ENGINE NOT READY -
606 10006 (SF) -
607 10007 START BLOKED -
608 10008 (SF) -
609 10009 PREPARING START -
610 10010 (SF) -
611 10011 REPEATED START -
612 10012 (SF) -
613 10013 START FAILURE -
614 10014 (SF) -
615 10015 LOAD LIMITATION -
616 10016 (SF) -
617 10017 LIMITATION INCREASE -
618 10018 (SF) -
619 ECR FORCED COMMAND TAKE OVER SIGNAL FROM EICU (1:ON) -
620 ECR FORCED COMMAND TAKE OVER (SF) SIGNAL FROM EICU (1:ABN.) -
621 LOCAL FORCED COMMAND TAKE OVER SIGNAL FROM EICU (1:ON) -
622 LOCAL FORCED COMMAND TAKE OVER (SF) SIGNAL FROM EICU (1:ABN.) -
623 10023 MAIN STARTING VALVE BLOCKED -
624 10024 (SF) -
625 10025 START AIR DISTRIBUTION SYSTEM BLOKED -
626 10026 (SF) -
627 10027 CONTROL AIR VENTED -
628 10028 (SF) -
629 10029 TURNING GEAR ENGAGED -
630 10030 (SF) -
631 10031 STARTING AIR PRESSURE LOW -
632 10032 (SF) -
633 LAMP TEST SIGNAL FOR LOP (1:ON) -
634 LAMP TEST SIGNAL FOR LOP (SF) SIGNAL (1:ABN.) -
635 10035 SG REQUEST -
636 10036 (SF) -
637 10037 SG PERMISSION -
638 10038 (SF) -
639 10039 SG DISCONNECTION FAILED -
640 10040 (SF) -
641 10041 LINE ALIVE HANDSHAKE -
642 10042 (SF) -
643 10043 BRIDGE FORCED COMMAND TAKEOVER (PITCH BACK-UP MODE) -
644 10044 (SF) -
645 10045 ASTERN BACK UP MODE -
646 10046 (SF) -
647 10047 SPARE -
648 10048 (SF) -
649 10049 SLOW COMMAND -
S.NO.SN2284 7SH68974-02D 33/39
FOR SAFETY
ADJUSTABLE
TENKEY RANGE
SETTING VALUE
ADDRESS DESCRIPTION UNIT
LOWER UPPER 1 2 3 4
650 10050 (SF) -
651 10051 ZERO PITCH REQUEST -
652 10052 (SF) -
653 10053 AUX. BLOWER FAILURE -
654 10054 (SF) -
655 10055 DELAYED START -
656 10056 (SF) -
657 AHEAD COMMAND SIGNAL FROM EICU (1:ON) -
658 AHEAD COMMAND SIGNAL FROM EICU (SF) SIGNAL (1:ABN.) -
659 ASTERN COMMAND SIGNAL FROM EICU (1:ON) -
660 ASTERN COMMAND SIGNAL FROM EICU (SF) SIGNAL (1:ABN.) -
661 10061 NEAR LIMIT -
662 10062 (SF) -
663 10063 PITCH NOT IN ZERO POS. DURING START (START BLOCK) -
664 10064 (SF) -
665 BRIDGE CONTROL SELECTED SIGNAL FROM EICU (1:BRIDGE CONTROL) -
666 BRIDGE CONTROL SELECTED SIGNAL (SF) SIGNAL (1:ABN.) -
667 ECR CONTROL SELECTED SIGNAL FROM EICU (1:ECR CONTROL) -
668 ECR CONTROL SELECTED SIGNAL (SF) SIGNAL (1:ABN.) -
669 LOCAL CONTROL SELECTED SIGNAL FROM EICU (1:LOCAL CONTROL) -
670 LOCAL CONTROL SELECTED SIGNAL (SF) SIGNAL (1:ABN.) -
671 10071 SPARE -
672 10072 (SF) -
673 10073 TIER III SYSTEM ACTIVATED -
674 10074 (SF) -
675 10075 TIER III NOX REDUCTION ACTIVE -
676 10076 (SF) -
677 10077 PREPARE TIER III FACILITY AVAILABLE -
678 10078 (SF) -
679 10079 PREPARE TIER III SELECTED -
680 10080 (SF) -
681 10081 SPARE -
682 10082 (SF) -
683 10083 SPARE -
684 10084 (SF) -
685 10085 SPARE -
686 10086 (SF) -
687 10087 SPARE -
688 10088 (SF) -
689 10089 SPARE -
690 10090 (SF) -
691 10091 SPARE -
692 10092 (SF) -
693 10093 SPARE -
694 10094 (SF) -
695 10095 SPARE -
696 10096 (SF) -
697 10097 SPARE -
698 10098 (SF) -
699 10099 SPARE -
S.NO.SN2284 7SH68974-02D 34/39
FOR SAFETY
ADJUSTABLE
TENKEY RANGE
SETTING VALUE
ADDRESS DESCRIPTION UNIT
LOWER UPPER 1 2 3 4
700 10100 (SF) -
701 10101 SPARE -
702 10102 (SF) -
703 10103 SPARE -
704 10104 (SF) -
705 10105 SPARE -
706 10106 (SF) -
707 10107 SPARE -
708 10108 (SF) -
709 10109 SPARE -
710 10110 (SF) -
711 10111 SPARE -
712 10112 (SF) -
713 10113 SPARE -
714 10114 (SF) -
715 10115 SPARE -
716 10116 (SF) -
717 10117 SPARE -
718 10118 (SF) -
719 10119 SPARE -
720 10120 (SF) -
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
S.NO.SN2284 7SH68974-02D 35/39
FOR SAFETY
ADJUSTABLE
TENKEY RANGE
SETTING VALUE
ADDRESS DESCRIPTION UNIT
LOWER UPPER 1 2 3 4
800
801 A30001 ACTIVE ENGINE (RUNNING) MODE -
802 A30002 SPEED SET POINT FROM LOCAL RPM
803 A30003 START AIR PRESS. BAR
804 A30004 ACTUAL PITCH (NOT USE) %
805 A30005 INDEX MARGIN (NOT USE) %
806 A30006 ACTUAL SPEED SET POINT RPM
807 A30007 FUEL INDEX %
808 A30008 SPEED SET FROM BRIDGE RPM
809 A30009 SPEED SET FROM ECR RPM
810 A30010 ACTUAL SPEED RPM
811 A30011 LINE ALIVE HANDSHAKE -
812 A30012 (SPARE) -
813 A30013 (SPARE) -
814 A30014 (SPARE) -
815 A30015 FIXED LOAD LIMIT %
816 A30016 ESTIMATED ENGINE POWER %
817 A30017 DUAL FUEL STATUS -
818 A30018 TIER III STATUS -
819 A30019 (SPARE) -
820 A30020 (SPARE) -
821 A30021 (SPARE) -
822 A30022 (SPARE) -
823 A30023 (SPARE) -
824 A30024 (SPARE) -
825 A30025 (SPARE) -
826 A30026 (SPARE) -
827 A30027 (SPARE) -
828 A30028 (SPARE) -
829 A30029 (SPARE) -
830 A30030 (SPARE) -
831 A30031 (SPARE) -
832 A30032 (SPARE) -
833 A30033 (SPARE) -
834 A30034 (SPARE) -
835 A30035 (SPARE) -
836 A30036 (SPARE) -
837 A30037 (SPARE) -
838 A30038 (SPARE) -
839 A30039 (SPARE) -
840 A30040 INTERFACE VERSION NUMBER -
841 A30041 CONFIGURATION NUMBER -
842
843
844
845
846
847
848
849
S.NO.SN2284 7SH68974-02D 36/39
FOR SAFETY
ADJUSTABLE
TENKEY RANGE
SETTING VALUE
ADDRESS DESCRIPTION UNIT
LOWER UPPER 1 2 3 4
850
851 D30001 SF SIGNAL (ACTIVE ENGINE RUNNING MODE) -
852 D30002 SF SIGNAL (SPEED SET POINT FROM LOCAL) -
853 D30003 SF SIGNAL (START AIR PRESS.) -
854 D30004 SF SIGNAL (ACTUAL PITCH (NOT USE)) -
855 D30005 SF SIGNAL (INDEX MARGIN (NOT USE)) -
856 D30006 SF SIGNAL (ACTUAL SPEED SET POINT) -
857 D30007 SET SIGNAL (FUEL INDEX) -
858 D30008 SF SIGNAL (SPEED SET FROM BRIDGE) -
859 D30009 SF SIGNAL (SPEED SET FROM ECR) -
860 D30010 SF SIGNAL (ACTUAL SPEED) -
861 D30011 SF SIGNAL (LINE ALIVE HANDSHAKE) -
862 D30012 SF SIGNAL (SPARE) -
863 D30013 SF SIGNAL (SPARE) -
864 D30014 SF SIGNAL (SPARE) -
865 D30015 SF SIGNAL (FIXED LOAD LIMIT) -
866 D30016 SF SIGNAL (ESTIMATED ENGINE POWER) -
867 D30017 SF SIGNAL (DUAL FUEL STATUS) -
868 D30018 SF SIGNAL (TIER III STATUS) -
869 D30019 SF SIGNAL (SPARE) -
870 D30020 SF SIGNAL (SPARE) -
871 D30021 SF SIGNAL (SPARE) -
872 D30022 SF SIGNAL (SPARE) -
873 D30023 SF SIGNAL (SPARE) -
874 D30024 SF SIGNAL (SPARE) -
875 D30025 SF SIGNAL (SPARE) -
876 D30026 SF SIGNAL (SPARE) -
877 D30027 SF SIGNAL (SPARE) -
878 D30028 SF SIGNAL (SPARE) -
879 D30029 SF SIGNAL (SPARE) -
880 D30030 SF SIGNAL (SPARE) -
881 D30031 SF SIGNAL (SPARE) -
882 D30032 SF SIGNAL (SPARE) -
883 D30033 SF SIGNAL (SPARE) -
884 D30034 SF SIGNAL (SPARE) -
885 D30035 SF SIGNAL (SPARE) -
886 D30036 SF SIGNAL (SPARE) -
887 D30037 SF SIGNAL (SPARE) -
888 D30038 SF SIGNAL (SPARE) -
889 D30039 SF SIGNAL (SPARE) -
890 D30040 SF SIGNAL (SPARE) -
891 D30041 SF SIGNAL (SPARE) -
892
893
894
895
896
897
898
899
S.NO.SN2284 7SH68974-02D 37/39
FOR SAFETY
ADJUSTABLE
TENKEY RANGE
SETTING VALUE
ADDRESS DESCRIPTION UNIT
LOWER UPPER 1 2 3 4
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916 AMS SIGNAL CHECK (DO1-16) -
917 AMS SIGNAL CHECK (DO17-32) -
918 AMS SIGNAL CHECK (DO33-48) -
919 AMS SIGNAL CHECK (DO49-64) -
920 AMS SIGNAL CHECK (DO65-80) -
921 AMS SIGNAL CHECK (DO81-96) -
922
923
924
925
926
927
928
929
930
931 AMS SIGNAL CHECK (DI1-16) -
932 AMS SIGNAL CHECK (DI17-32) -
933 AMS SIGNAL CHECK (DI33-47) -
934 AMS SIGNAL CHECK (AI40001) -
935 AMS SIGNAL CHECK (AI40002) -
936 AMS SIGNAL CHECK (AI40003) -
937
938
939
940 INTERFACE VER. NO. MISMATCH INTERNAL (1: ABNORMAL) -
941 LINE ALIVE (DIGITAL) ABNORMAL EICU_A (1: ABNORMAL) -
942 LINE ALIVE (DIGITAL) ABNORMAL EICU_B (1: ABNORMAL) -
943 LINE ALIVE (ANALOG) ABNORMAL EICU_A (1: ABNORMAL) -
944 LINE ALIVE (ANALOG) ABNORMAL EICU_B (1: ABNORMAL) -