LEGEND

Power socket at 1.2 m from floor


level
Power socket at 0.3 m from floor
level
RADIATION HOUSE
Isolators
3 Phase Isolators
Data socket
se Non standard power socket
hou
t i on
adia 12 way main
e to r distribution board
pip 150X150X70 MM ADB
VC Contactor (60A) master
mP
AC control board
2m
in 3 6 way sub main distribution
les board
t cab
dui Power connection from manhole
con to main DB to AC sub main DB
und
d g ro Power connection from main DB
c eale to P1 sockets
con
mm
Power connection from main DB
3X4
to P2 sockets
Power connection from main DB
150X150X70 MM ADB to isolators
Power connection from main DB
to 3 phase isolators
Power connection from main DB
MH

to trunking system
Trunking system
4x
35
m
m
ar
m
ou
re
dc
ab
le
in
50
m
m
PV
C
co
nd
uit
Main DB Floor Concealed 25 mm PVC Conduit
Connecting board to trunk
NOTE
1. All isolators get straight supply from the main board as
shown protected with individual circuit breaker.
4X16 mm conduit cables concealed in 50 mm PVC pipe to sub main AC board 2. All P2 sockets get straight supply individually from the
main board as shown protected with individual circuit
breaker.
3. All P1 sockets get supply from the board but are looped
as a ring circuit in the truncking system and concealed
floor conduits.
4. All 3 phase isolators get straight supply form the main
board individually
5. All data connections are in the trunking system
6. Isolators are supplied with 4 mm conduit cables run in
floor concealed and roof run conduits.
7. Some P2 sockets are run in concealed floor conduits
with 2.5 mm cable drawn in 32 and 25 mm
PVC Hvg conduits.
8. P2 sockets are mounted above the floor slab level at
1.2 m high.
9. P1 sockets are mounted at 300 mm above the floor
AC's DB slab level.
10. Sub main AC board including fan and air conditions are
run with 5x16mm cables in 50 mm floor concealed
conduits from main DB
11. The main distribution cable is 4x32 mm armoured cable
Floor Concealed 25 mm PVC Conduit

in 50 mm PVC hvg conduits from the Manhole as shown.


12. Mobile equipment board gets power from main DB, but
is plugged at one industrial socket point.
AFRICA RESOURCES LIMITED
P.O. BOX 1846-80100
MOMBASA
SUBCONTRACT OF CONSTRUCTION OF
LABORATORY; RENOVATION OF
EXISTING OFFICE BLOCK;ASSOCIATED
EXTERNAL CIVIL AND ELECTRICAL
WORKS;
AGREEMENT No. ICB No.
KAA/ES/MIA/617/C
REHABILITATION OF AIRSIDE PAVEMENTS
AND AIRFIELD GROUND LIGHTING (AGL)
SYSTEM AT MOI INTERNATIONAL AIRPORT
30/11/2018 Eng. Theodore Kahi
NTS ARL-KAA-E001
LABORATORY POWER SUPPLY AS BUILT DRAWINGS