Professional Documents
Culture Documents
GENERAL INFORMATION
1. General Information :
Name of Project: Dhanaura WSP Survey Date:
VDC/Municipality: Bhajini Municipality Surveyed B y:
District: Kailali
2. Accessibility
Distance from district headquarter Dhangadhi to project area : 67 km
Name of the nearest market for construction materials: : Dhangadhi
Distance from project area to nearest market : 67 km
Name of the nearest all weather roadhead : project site
Note: SP-spring, ST- stream, SFS- spring fed stream Clear (C)/ Tubid (T) Vegetation: Good(G)/Medium(M)/poor(P)
WS- Water supply, IR- Irrigation , WM- water mill Pleasure (P)/Unpleasure (UP) Upstream settlement : Yes(Y)/No(N)
Date in english calender Yes (Y)/No(N) Landslide possibility : Yes(Y)/No(N)
Erosion possibility: Yes(Y)/ No(N)
Annex-3
PRESENT POPUATION & HOUSEHOLDS IN THE PROJECT AREA
Total 150
Annex-5
HOUSEHOLD & POPULATION PROJECTION
Name of Project:- Dhanaura WSP Design Period : 15 Years Municipality: Bhajini District: Kailali
Survey Year ( 2019 ) Base Year ( 2022 ) Design Year ( 2037 ) Institutional
Annual
Schem Scheme
Villages/ Communities Ward no. growth
No. Name Present Design
HH Pop. rate % HH Pop. HH Pop.
population population
1 Dhanaura 4,9 966 5796 1.5 1010 6061 1263 7577 5796 7577
Pumping hour:
Shift-1 5.00 AM- 8:00 AM
Shift-2 15.00 PM- 18.00 PM
Excess Water in
Draw off Water demand Accumulated Pumping Water pumped Accumulated Excess demand
Time Hours pumping reservoir
factor litres demand litres hour litres pumping litres (5-8) litres
(8-5) litres litres
1 2 3 4 5 6 7 8 9 10 11
05.00-07.00 2 0.25 156326 156326 2 259200 259200 102874 317190
07.00-12.00 5 0.35 218856 375182 1 129600 388800 -13618 227934
12.00-15.00 3 0.20 125060 500242 0 0 388800 111442 102874
15.00-21.00 6 0.20 125060 625303 3 388800 777600 152297 366614
21.00-05.00 8 0.00 0 625303 777600 152297 214316
24 1.00 625302.848145 6
Maximum excess demand + Maximum excess supply = 214316 litres
Recommended to provide an overhead RCC water tank of = 214.31635530624 m3 capacity
225 cumec Tank recommended
Annex-8
PUMPING MAIN AND PUMP
Name of Project:- Dhanaura WSP District: Kailali
Total designed demand to be supplied through elevated water tank : 625302.464 liters/day
: 625.30 m3/day
Number of tubewell : 2 No.
Designed average pumping rate from each tubewell : 18.00 lps
1080 lpm
Total pumping hours : 6.00 hours
1 Pumping Main
Approximate length of pumping main : 80 m
Assume flow rate v = 2.25 m/s. Then required diameter of the pumping main
d=
0.100905 = 100.90 mm
Recommended to use 150 mm Ø DI pipe in the pumping main.
Then, flow rate v = 1.02 m/s
2 Total Pumping Head
Assumed static water level during dry period = 30.00 m BGl
Assumed maximum drawdown due to pumpage = 20.00 m
Headloss in the pumping main (including in fittings) = 2.00 m
Reservoir head = 25.475 m
Residual head = 5.00 m
Total pumping head required Total = 82.48 m
Recommend to provide a 8" borewell submersible pump confirming to IS : 8034 as per requirement
total pumping head of 83 m. However, actual design & selection of pump shall be done only after draw
down test of tube well
3 Shaft Horse Power of the Pump
Np = Q.H.ρ.g/ηp Where
= 25x 10-3 x 84 x 1000 x 9.81 / 0.68
= 21553 watt
21.55 kW
28.89 HP
4 Shaft Horse Power of Electric Motor
Nm = Np/(ηt.ηr) Where
= 35.92 / (0.9 x 0.9) ηt = efficiency of transmission ( 90% assumed)
= 26.61 Kw ηr = other efficiency coefficients related to altitude,
= 35.67 HP temperature, humidity etc. ( 90% assumed)
Say 50 HP
5 Rated Capacity of Electric Transformer
Power required for operation of the pump shall be obtained through 3-Phase Central Electric Grid.
Rated Capacity of electric transformer = Power input to the pump moter + Power for other uses
= (36.96+5)/0.8 = 39.51 KVA