DESIGN CALCULATION

PROJECT NAME : SIZE UP LINE BRINE D‐200B DOC No. : T4/23/SA‐72/0621


PROJECT CODE : SA‐72 Rev/Page : 1 / 12 OF 13
CUSTOMER : PT. SULFINDO ADIUSAHA DATE : 30 Juni 2021

MECH. CALCULATION
FRP BLIND FLANGE
ASME NM 2 ‐ 2018

7. Design For FRP BLIND FLANGE
Thickness design By HLU methode
Thickness design By HLU methode

Formula :

Reffer Asme NM 2 ‐ 2018 Page 21

Where :
‐  Corrosion Barrier = 3 mm
‐ Bolt circle diameter, Dbc = ANSI #150
‐ Internal design pressure, P = 10 BarG = 1 Mpa By design
‐ Hoop tansil stress, S = 76 Mpa (ASTM C‐582, Tabel 4, page 4)

Tabel.5 Summary Thickness of FRP Blind Flange
Pipe Dia c Dbc P S Min. Thick Use thicknes
No
(mm) (mm) (mm) (Mpa) (Mpa) t (mm)
t (mm) t + C (mm)
t + C (mm)
1 25 3 79.4 1 76 7.1 20

Note :
‐ the use of thicknes has been adjusted to what is offered
‐ Use laminate type 2