The most durable

gas chlorinator
on the market…

SERIES 200

GAS
CHLORINATORS
• Potable Water Systems • Industrial Process Water
For…


• Sanitary Sewage • Industrial Waste Water
• Community Water Systems • Power Plants • Swimming Pools & Fountains

EASY INSTALLATION: Advanced product design eliminates the probability of


troublesome installations.

FEWER PARTS: Proven product engineering results in fewer parts for


exceptional operating reliability, lower cost, and longer life.

TOTAL RELIABILITY: Every part is optimally designed and manufactured using


materials proven to be chemically resistant to chlorine gas.
Therefore, Hydro Instruments’ Series 200 components can be
used to handle chlorine gas with safety and complete control
at capacities from 10 to 250 lbs/day (200 to 5000 grams/hour).

PROUDLY

INSTRUMENTS MADE IN USA

600 Emlen Way, Telford, PA 18969 • Telephone: (215) 799-0980 • Fax: (215) 799-0984
BULLETIN 200 Rev. 4/15 Toll Free in the U.S.: 1 (888) 38-HYDRO • www.hydroinstruments.com • sales@hydroinstruments.com
GAS CHLORINATORS
Hydro Series 200 cylinder or manifold
mounted gas chlorinators are designed
for manual or semi-automatic operation to
meet the highest standards of reliability.
They incorporate advanced design features
gained through years of research and in-
the-field experience. Simplified design and
fewer parts mean less maintenance, less
cost with better performance, reliability and
long life.

Principle of Operation
For a particular ejector back pressure,
a minimum water supply is required at the
ejector inlet to create vacuum at a level
strong enough to operate the chlorinator.
This vacuum originates in the throat of the
ejector’s Venturi nozzle and after opening
the ejector check valve, extends into the
body of the chlorinator. There it causes
the regulating diaphragm to open the inlet
safety valve, allowing gas under pressure
to enter the chlorinator. As it flows across HYDRO Series 200 Chlorinator
the inlet safety valve assembly, it is filtered A heavy steel yoke is used to mount the Inlet Sealing Valve
and reduced to a vacuum. Hydro chlorinator directly to the cylin-
The gas then enters a chamber where der. This eliminates all pressure lines. A sealing valve at the chlorinator inlet
the vacuum level is maintained by a spring- Chlorine gas is taken under vacuum to closes if chlorine supply is interrupted
opposed, sealed regulating diaphragm. the point of injection. This eliminates or depleted, sealing the entire vacuum
It is then drawn through the chlorine flow pressurized solution lines. system. Dirt or moisture cannot enter the
meter, across the rate control valve and on system when cylinders are changed.
to the ejector where it dissolves in water. Operator Indicator
The resultant, highly concentrated solution Regulating Diaphragm
exits at the ejector outlet and flows to the During operation the indicator window
remains gray; red indicates depletion of Constant vacuum level is maintained inside
desired point of application.
the chlorine source. the chlorinator by the diaphragm which is
Accuracy O-ring sealed along its entire inner and
Flow meter accuracy is within 4% of the Inlet Safety Valve outer surface to prevent leakage or warping
meter’s maximum capacity. of parts from excessive tightening of the
Spring opposed safety valve seals off body bolts.
Capacities Available chlorine in cylinder upon loss of vacuum.
250 pounds per day (5000 grams per hour). Safety valve is encapsulated to permit
Minimum feed rate is 5% of maximum. quick disassembly and cleaning without
special tools.
Installation of Hydro Gas Chlorinators
Units of the Hydro Gas Chlorinator Sys-
tem can be used for practically any require-
ment. The schematics show various types
of installations using single or multiple
cylinders as well as application of chlorine
to pool, basin or pipeline…
direct or remote. Basic HYDRO gas chlori-
nator units are simply combined to cover all
applications.
Hydro Model (T or W)* 200 Hydro Model (T or W)* 201
Chlorinator size should be based Single-Point Application Remote Meter for Single Point of
on maximum possible flow. Application
Hydro chlorinator mounted on a single
GPM x 0.012 x (PPM) Dosage = PPD
cylinder with direct ejector to pipeline Hydro chlorinator mounted on a single
Example: or basin. Chlorine capacity to 250 PPD cylinder feeding a remote wall mounted
600 GPM x 0.012 x 3 PPM = 21.6 PPD (5000 grams/hr). meter with rate valve supplying a single
ejector. Chlorine capacity to 250 PPD
In this example a Hydro 50 PPD chlorinator Vent to outside (5000 grams/hr).
would be adequate.
* When ordering: Prefix # with T for ton container mounting or W for wall manifold or cylind
A complete system for totally reliable control.

HYDRO EJ-2000 Ejector HYDRO RM-200 Remote Meter HYDRO SP-200 Automatic
The Hydro ejector utilizes a specially Any number of Hydro Remote Meters Switchover
designed O-ring seal check valve which may be used in an installation if required. Multiple chlorine cylinders, which prolong
prevents the backflow of water into the Only the vacuum line is required to the the time span before depletion, are easily
chlorinator. The ejector operates on a ven- individual ejector which it supplies. Chlo- installed and automatically switch over from
turi created by water passing through the rine gas can then be precisely metered at a depleted cylinder to the unused cylinder.
ejector nozzle causing the spring opposed each remote location. If more (or less) is A Hydro Chlorinator is installed on each
diaphragm check valve to open and mix required at one location the meter is sim- cylinder and only one Automatic Switchover
the chlorine gas with the water. The ejector ply set at the desired level for that loca- is required to handle the two cylinders. The
should be supplied with reasonable clean tion. By this control of metering at remote Hydro Automatic Switchover can be used
water at temperatures below 110°F (43°C). locations a perfectly balanced system can with either one remote meter or with two or
The Hydro ejector is made of durable be maintained. Hydro Remote Meters more remote meters. Use of this switcho-
materials that are resistant to wet and dry are practically maintenance free. ver module is a great time saver and is a
chlorine gas use. great aid in assuring a more constant sup-
ply of chlorine. Once installed, the Hydro
Automatic Switchover is completely auto-
INSTRUMENTS matic and needs no adjustment or setting.

600 Emlen Way, Telford, PA 18969 • Telephone: (215) 799-0980 • Fax: (215) 799-0984
Toll Free in the U.S.: 1 (888) 38-HYDRO • www.hydroinstruments.com • sales@hydroinstruments.com

Hydro Model (T or W)* 201-2 Hydro Model (T or W)* 202 Hydro Model (T or W)* 202-2
Multi-Point Application Automatic Stand-By Automatic Stand-By with Multi-Point
Feeding
Hydro chlorinator mounted on a single Hydro chlorinators – two chlorinators
cylinder feeding two remote meters for two mounted on two cylinders with switcho- Hydro chlorinators – two chlorinators
points of injection using two ejectors. Each ver module feeding one remote meter mounted on two cylinders with switcho-
meter and ejector operates independently. with rate valve feeding a single ejector. ver module feeding two or more remote
Chlorine capacity to 250 PPD (5000 Capacity to 250 PPD (5000 grams/hr) meters with rate valves supplying two
grams/hr). maximum. ejectors. Capacity to 250 PPD (5000
grams/hr) maximum.
der mounting. (Manifold mounting requires additional equipment.)
Series 200
GAS CHLORINATORS

The installation of Hydro Gas Chlorinators is easily accomplished. The following will be useful information.
System Operating Temperatures Ejector Installation
For best operation and safety, the 1. Ejector connections must be kept 4. To create a vacuum the water supply
chlorinator and chlorine supply should be above freezing temperatures. to the ejector inlet must be higher than
protected from the elements and from the pressure at the point of application
2. At point of application maximum back
direct sunlight. (approximately 40 psig differential).
pressure for standard ejector is 145
Methods of Control psig. (High pressure ejectors are 5. Maximum ejector operating temperature
Manual available.) is 110° F (43° C).
Adjustment of rate valve and start/stop of 3. Long solution lines from ejector 6. Ejector may be wall mounted for remote
water to ejector. should be avoided and if not, solution applications.
Semi-Automatic lines must be of adequate ID to
• Shutting off booster pump to ejector. reduce friction loss.
• Using solenoid valve to close vacuum
line to ejector.
Series No. (PPD) Maximum Capacity Mounting
Step-Feed to multiple flow meters is
100 PPD 150 lb. cylinder, manifold*,
available using solenoid valves in the 500 Series
vacuum line or water line to the ejector. (2000 gr/hr) or ton container

250 PPD 150 lb. cylinder, manifold*,
STANDARD TUBING CONNECTIONS 200 Series
(5000 gr/hr) or ton container
Vacuum Tubing Size Vent
500 PPD
Feed Rate Length of Tubing 700 Series Ton container
100 Feet 200 Feet 25 Feet (10,000 gr/hr)
PPD Gr/Hr (30m) (60m) (7.5m) 500 PPD
750 Series Manifold
50 1000 3⁄8" (9.52mm) 3⁄8" (9.52mm) 3⁄8" (9.52mm)
(10,000 gr/hr)
100 2000 3⁄8" (9.52mm) 1⁄2" (12.7mm) 3⁄8" (9.52mm) * For manifold units there is the additional cost of wall mounting manifolds.
250 5000 1⁄2" (12.7mm) 5⁄8" (15.8mm) 3⁄8" (9.52mm)
500 10,000 5⁄8" (15.8mm) 3⁄4" (19mm) 3⁄8" (9.52mm)
Hydro Model EJ-2000
ACCESSORY EQUIPMENT AVAILABLE Ejector Connections
• Loss of Chlorine Alarm
Standard Options
• Multiple Remote Flow Meters
and Ejectors Ejector Water EN-275 Nozzle
None
• Inlet Water Assemblies Inlet (Nozzle) for 11⁄4" NPT
• Automatic Switchover System Ejector Water EDH-380 Diffuser for EDT-380 Diffuser
• Booster Pumps • Gas Masks Outlet (Diffuser) 11⁄2" ID Hose for 11⁄4" NPT
• Analyzers • Leak Detectors