INTEGRATED ELEVATOR CONTROLLER
FOR TRACTION LIFTS

EN81-21 RESET INSTRUCTIONS


Arcode EN81-21 Reset Instructions V1.10

Publisher Arkel Elektrik Elektronik San. ve Tic. A.Ş.


Eyüp Sultan Mah. Şah Cihan Cad. No:69 Sancaktepe/Istanbul 34885 TURKIYE
Tel: (+90 216) 540 03 10-11-12
Fax: (+90 216) 540 03 09
E-mail: info@arkel.com.tr
www.arkel.com.tr
Date of Isue 04.2020

Document Version V1.10

This document has been created to be a guide for Arkel customers. Reproduction, transfer, distribution or storage of part or all of the
contents in this document in any form without the prior written permission of Arkel is prohibited. Arkel reserves the right to make changes
and improvements to any of the products described in this document without prior notice.

Arkel is not responsible for those mistakes that may be found in this manual and for the damages that they may cause
Arcode EN81-21 Reset Instructions V1.10

1. EN81-21 RESET INSTRUCTIONS


If the safety system of reduced pit/headroom is ON, resetting the controller from the controller cabinet is necessary before a
normal operation. This should be necessary after opening a landing door by means of a key.

The reset only will be possible if:


• The inspection control on the top of the car is in “NORMAL” position.
• The inspection control in the controller cabinet is in “NORMAL” position.
• Both movable stops (under car and under counterweight) are in INACTIVE Position. This could be checked if the visual
signals of each movable stop are both RED.
• The lower part of the counterweight screen is correctly assembled.
• The car roof balustrades are FOLDED. (Only if applies).
• The foldable Apron is FOLDED (only for reduced pit).
• The STOP devices in pit and car roof are OFF.
• All landing doors and car door are correctly closed and locked and LED 119A is ON:

Keep the SRST switch turned to “1” position, and release it: