2018 British Columbia Building Code

Review of Proposed Changes


Provision 2012 BCBC 2018 BCBC Additional Comments
Reference Reference
Restaurants To public facilities and to Sentence 3.8.2.14.(1) Article 3.8.2.3., Note BC’s 2012 requirement for seating areas is that clear space,
spaces in seating areas A-3.8.2.3. which does not infringe upon aisles, is provided for persons in
(viewing positions) wheelchairs (not less than 1% of the seating area) and offers
viewing of any entertainment areas. Exempted areas carried
over in Sentence 3.8.2.1.(1) for assembly occupancies.
See Sentence 3.8.2.3.(3) and Table 3.8.2.3.(3) for areas with fixed
seats.
Lodge Rooms To all storeys (except Sentence 3.8.2.15.(1) Article 3.8.2.3., Note Service rooms and some other areas are be exempted by Clause
storeys containing only A-3.8.2.3. 3.8.2.3.(2).
mechanical and storage
areas)
Passenger Terminals To all areas to which the Sentence 3.8.2.16.(1) Article 3.8.2.3., Note
public is admitted A-3.8.2.3.
Schools and Colleges, Non- To at least one entrance, to Article 3.8.2.17. Article 3.8.2.3., Note See Sentence 3.8.2.3.(3) and Table 3.8.2.3.(3) for areas with fixed
residential parking stalls, to A-3.8.2.3., Article seats. See Sentences 3.8.2.8.(10) and (11) for showers and baths.
educational, recreational 3.8.2.4., Article
and refreshment facilities, 3.8.2.5., Article
to offices, to lockers, to 3.8.2.8.
work areas, to spaces in
seating areas (viewing
positions), to washrooms
and to showers and baths
Undertaking Premises To seating areas (viewing Sentence 3.8.2.18.(1) Article 3.8.2.3., Note See Sentence 3.8.2.3.(3) and Table 3.8.2.3.(3) for areas with fixed
positions) (and Article 3.8.3.15.) A-3.8.2.3. seats
Arenas and Ice Rinks To each public facility, Article 3.8.2.19. (and Article 3.8.2.3., Note See Sentence 3.8.2.3.(3) and Table 3.8.2.3.(3) for areas with fixed
changing rooms, and spaces Article 3.8.3.15.) A-3.8.2.3., Article seats. Example of change rooms is added to Appendix note A-
in seating areas (viewing 3.8.2.8. 3.8.2.3.
positions)
Swimming Pools To public facilities, spaces in Sentence 3.8.2.20.(1) Article 3.8.2.3., Note Example of change rooms is added to Appendix note A-3.8.2.3.
seating areas (viewing (and Article 3.8.3.15.) A-3.8.2.3., Article See Sentence 3.8.2.3.(3) and Table 3.8.2.3.(3) for areas with fixed
positions) and change 3.8.2.8. seats.
rooms
Bleachers (excluding To spaces in seating areas Sentence 3.8.2.21.(1) Article 3.8.2.3., Note See Sentence 3.8.2.3.(3) and Table 3.8.2.3.(3) for areas with fixed
temporary structures) (viewing positions) and A-3.8.2.3., Article seats.
washrooms 3.8.2.8.

Page 5 of 10
2018 British Columbia Building Code
Review of Proposed Changes
Provision 2012 BCBC 2018 BCBC Additional Comments
Reference Reference
Grandstands and Stadiums To offices, spaces in seating Article 3.8.2.22. Article 3.8.2.3., Note See Sentence 3.8.2.8.(10) for showers.
areas (viewing positions), A-3.8.2.3., Article
refreshment facilities and 3.8.2.4., Article
changing rooms (with 3.8.2.8.
showers)
Drive-in Theatres To refreshment facilities and Sentence 3.8.2.23.(1) Article 3.8.2.3., Note
washrooms A-3.8.2.3., Article
3.8.2.8.
Jails To main entrance, parking Sentence 3.8.2.24.(1) Article 3.8.2.3., Note
area, visitor area and visitor A-3.8.2.3., Article
washrooms 3.8.2.5., Article
3.8.2.8.
Psychiatric Hospitals and To main entrance, parking, Sentence 3.8.2.25.(1) Article 3.8.2.3., Note
Police Stations work areas, washrooms and A-3.8.2.3., Article
to each type of facility 3.8.2.5., Article
3.8.2.8.
Care and Treatment To main entrance, parking, Sentence 3.8.2.26.(1) Article 3.8.2.3., Note
Facilities work areas, washrooms and A-3.8.2.3., Article
to each type of facility 3.8.2.5., Article
3.8.2.8.
Apartment and To main entrance, parking Article 3.8.2.27. Article 3.8.2.3., Note Intercom requirements are located in Sentences 3.8.2.2.(6),
Condominium Buildings and an elevator (where A-3.8.2.3., Article 3.8.2.6.(1), and 3.8.3.8.(1). Outlet box requirements are located
provided) 3.8.2.5. in Sentences 3.8.2.6.(1) and 3.8.3.8.(1).
Clubs, Residential To membership facilities, Sentence 3.8.2.28.(1) Article 3.8.2.3., Note The example of ‘membership facility’ is added to the examples in
baths/showers and a A-3.8.2.3., Sentences appendix note A-3.8.2.3. Requirement for a visual warning
sleeping room (where 3.8.2.8.(10) and (11) system is located in 3.8.2.12.(3)(a)
sleeping accommodation is
provided for 10 or more)
Schools and Colleges, To entrance, parking stalls, Article 3.8.2.29. Article 3.8.2.3., Note See Sentence 3.8.2.3.(3) and Table 3.8.2.3.(3) for areas with fixed
Residential educational, recreational, (Article 3.8.2.17.) A-3.8.2.3., Article seats. See Sentences 3.8.2.8.(10) and (11) for showers and baths.
refreshment facilities, 3.8.2.5., Article Requirement for a visual warning system is located in
offices, lockers, work areas, 3.8.2.8., Article 3.8.2.12.(3)(a). A bathroom serving a bed space is regulated by
spaces in seating areas 3.8.2.12. Article 3.8.3.22. Bed space requirements are located in Sentence
(viewing positions), 3.8.2.12.(2).
washrooms, showers/baths
and 1 of 40 bed spaces