Data Category Field Modification Trouble Shooting General Information Safety Advice
[Modification]
1.Added Test Mode No.91 (Position-A adjustment)
Test-mode No.91 has been changed the functions for KS500/600 series.
#Old program : Ver1.12 or less #New Program : Ver1.50
Shading compensation Position-A adjustment
91 Position-A adjustment
Description Position-A adjustment
Setting Range : -4 ~ +3 (-4 degree ~ +3 degree)
(+ : increase , - decrease)
Unit : 1 degree in angle per 1 range)
Default: 0
Attached:
[Modification procedure]
Step 1 Replace the EPROM with a new version (KSS/V1.50)
Step 2 Replace the Drum Support BKT F with a new type if the machine has the old type.
Step 3 Remove the position-A sensor from the BKT and set the sensor in the additional holes on the BKT
as shown on the photo.
[Notice]
If you upgrade to KSS/Ver. 1.50 on an old type Drum Support BKT F, E3 (Clamp Motor Lock) might occur.
*After Upgrade to “KSS/Ver. 1.50” of the machine with a old type “Drum Support BKT F”.
{Newly-registered Parts]
1. 035-52000-500 : EPROM:KSS/V1.50
2. 035-16401-205 : Drum Support BKT F
Attached: