Professional Documents
Culture Documents
is an
acknowledged leader in trading electrical
and telephone accessories in the Kingdom of
Saudi Arabia.
Contents
BW Brass Cable Glands 1
CW Brass Cable Glands 2
A1A2 Brass Cable Glands 3
Siemens Type Glands 4
Screws, Bolt and Clamps 5
Rod, Plate Coal and Pit 6
Rod, Base and DC Tape Clip 7
Flexible Braid 8
CABLE GLANDS
B A D
F E
TYPE : BW
SPECIFICATION : BS 6121 PART 1 1989 H
FINISH: PLAIN BRASS OR NICKEL PLATED
CABLE TYPE : STEEL WIRE ARMOURED
ARMOUR CLAMPING : 2 PART ARMOUR LOCK
Cable Dimensions
Gland Dimensions (mm)
Accommodated (mm)
1
CABLE GLANDS
A D
B
F E
TYPE : CW
G
SPECIFICATION : BS 6121 PART 1 1989
FINISH: PLAIN BRASS OR NICKEL PLATED
CABLE TYPE : STEEL WIRE ARMOURED
ARMOUR CLAMPING : 3 PART WITH LOCKNUT H
SEALING TECHNIQUE : COMPRESSION TYPE
SEALING AREA : OUTER SHEATH
Brass indoor and outdoor gland most popularly used with single wire
armoured, plastic or rubber sheathed cable. Terminates and secured
cable armouring and outer seal grips sheathed of cable thus ensuring
mechanical strength and earth continuity Recommended to use PVC
shroud for additional protection.
Cable Dimensions
Accommodated Gland Dimensions (mm)
(mm)
CODE Approx.
Under
Overall Armour ISO Entry Length
Armour Hexagon Size
Max Wire Dia. Thread From
Max
Shoulder
A B C D E F A/F G A/C(H)
P-IND-GCW-20L 13.90 11.70 20.80 0.90/1.25 20.00 10.00 46.00 30.50 34.00
P-IND-GCW-25L 19.90 17.00 27.20 1.25/1.60 25.00 10.00 51.00 37.60 42.20
P-IND-GCW-32L 26.20 23.50 33.50 1.60/2.00 32.00 10.00 56.00 47.30 53.60
P-IND-GCW-40L 32.10 29.00 39.90 1.60/2.00 40.00 15.00 59.00 56.40 61.50
P-IND-GCW-50L 44.00 39.50 52.60 2.00/2.50 50.00 15.00 64.00 70.10 77.20
P-IND-GCW-63L 55.90 51.30 65.30 2.50 63.00 15.00 67.00 80.00 87.40
P-IND-GCW-75L 67.90 62.50 78.00 2.50 75.00 15.00 76.00 98.00 109.20
2
CABLE GLANDS
D A
E F
TYPE : A1A2
SPECIFICATION : BS 6121 PART 1 1989
H
FINISH: PLAIN BRASS OR NICKEL PLATED
CABLE TYPE : UNARMOURED
SEALING TECHNIQUE : DISPLACEMENT TYPE
SEALING AREA : OUTER SHEATH
Cable Dimensions
Gland Dimensions (mm)
Accommodated Dimensions (mm)
Cat. Code Overall Diameter ISO Entry Hexagon Hexagon
A Thread Size Size
3
CABLE GLANDS
A
1 B
A-1
4
5
6
TYPE : SIEMENS TYPE
SPECIFICATION : BS 6121 PART 1
FINISH: NICKEL PLATED
CABLE TYPE : UNARMOURED 7
SEALING TECHNIQUE : SINGLE COMPRESSION TYPE
SEALING AREA : OUTER SHEATH C
D
Code A mm B mm C mm D mm
P-IND-G1/2 18.00 16.00 12.00 16.00
4
EARTHING/LIGHTNING
CABLE GLANDS
ACCESSORIES
EARTH SCREW
Code Description
P-IND-BI Brass terminal screw
Terminal screws are used for switchgears, electrical fuses panel boards and
switchboard hardware. Brass connectors are mainly used as accessories in electrical
wiring boards and panel boards by various industries like electrical, electronics and
telecommunications.
EARTH POINTS
Code Hole Size Length
P-IND-EPS M10 X 15mm 80mm
Earth points available for direct connection to conductors, or with additional pre-
welded tail (single or double 70 mm2 PVC insulated cable) to enable connection to
internal rebar arrangements via mechanical clamps. When used in concrete structures
offer convenient ground system connection points.
They used where reinforcing bars are electrically continous and are to be used as
down conductors. These earth points allow easy access for the lightning protection
and earthning system.
SPLIT BOLTS
Code Size Code Size
P-IND-SB6 6mm P-IND-SB120 120mm
P-IND-SB10 10mm P-IND-SB150 150mm
P-IND-SB16 16mm P-IND-SB185 185mm
P-IND-SB25 25mm P-IND-SB240 240mm
P-IND-SB35 35mm P-IND-SB300 300mm
P-IND-SB50 50mm P-IND-SB350 350mm
P-IND-SB70 70mm P-IND-SB400 400mm
P-IND-SB95 95mm
High strength copper alloy clamp designed to provide a high quality, low resistance
connection between solid circular or stranded conductor and an earth rod. Corrosion
resistance, conductivity and mechanical strength are essential considerations in
clamp design to ensure an earthing system remains operative
for many years.
5
EARTHING/LIGHTNING ACCESSORIES
EARTH ROD
Code Length Diameter of Actual Rod
Thread Diameter
P-IND-ER1.5 1500mm 14.15mm 16mm
P-IND-ER3 3000mm 14.15mm 16mm
Earth rods and plates or any combination thereof can be used to achieve an
effectiveness earth depending on the site conditions. Earth rods take advantage of
lower resistivity soils at greater depths than normal excavation will allow.
EARTH PLATE
Code Length Width Thickness
P-IND-EP3 50mm 50mm 3mm
P-IND-EP7 70mm 70mm 3mm
Earth plates are used to attain an effective earth in shallow soils with underlying rocks
or in locations with large amounts of buried services. They can also provide protection
at potentially dangerous places e.g. HV switching positions.
EARTH PIT
Code Length Width Height
P-EP 310mm 310mm 290mm
Regular inspection and testing of the earthing system is essential. Inspection pits
allow easy access to earth electrodes and conductors to facilitate this procedure.
The concrete earth pit is suitable for most types of earthing and lightning protection
installations. The Pit can have an earth bar fitted diagonally across in slots provided
for multiple connections.
6
EARTHING/LIGHTNING ACCESSORIES
MULTIPLE POINT
Code Size Max Conductor Size
P-L-LA-MP 16mm 16mm
Multiple point air rods are designed to protect rooftop mounted or exposed equipment
such as air conditioning units photovoltaic panels from a direct lightning strike. Multiple
points are made from copper clloy & the taper spike from EC grade copper.
AIR ROD
Code Rod Dimension Length of Actual Rod
Rod Diameter
P-L-LA-ATR 16mm 500mm 16mm
These rods are made up of high conductivity EC Grade Copper and Aluminum.
Mechanically cladded copper coated grounding rod is made electrolytic grade 99.9%
copper tube with wall thickness of 0.25 (250 microns) is cladded to a low carbon steel
rod.
TERMINAL BASE
Code Size
P-L-LA-ATB 16mm
For supporting air rods onto flat roof surfaces and to accommodate conductor tape for
lightning protection system. These saddles can be installed horizontally on roofs and
are used in conjunction with the air rods.
DC TAPE CLIP
Code Width Thickness
P-L-DCT 25mm 3mm
7
EARTHING/LIGHTNING ACCESSORIES
Technical Data
20°C Direct current
STRUCTURE
Section Size (mm) resistance Ω/km not more
Number of Calculating
than
Skeins x threads/ weight
The width
diameter of a Thickness kg/km
Standard Calculating not more Copper (Cu) Tin (Sn)
single thread for reference
than
4 3.39 48 x 4 x 1/0.15 9 1.0 3.36 6.65 34
4 3.82 36 x 6 x 1/0.15 9 1.5 5.64 5.89 35
6 5.09 48 x 4 x 4/0.15 12 1.2 4.23 4.42 51
10 10.18 48 x 12 x 1/0.15 20 1.4 2.12 2.22 101
10 10.18 48 x 16 x 1/0.15 16 2.0 2.12 2.225 102
16 16.96 48 x 20 x 1/0.15 22 2.0 1.27 1.33 170
16 16.54 36 x 26 x 1/0.15 20 2.5 1.30 1.35 166
20 20.36 36 x 32 x 1/0.15 22 3.0 1.06 1.10 204
25 25.44 48 x 30 x 1/0.15 22 3.0 0.85 0.89 254
25 25.44 36 x 40 x 1/0.15 26 3.0 0.85 0.89 254
35 33.93 48 x 20 x 2/0.15 26 3.2 0.64 0.67 340
35 35.62 36 x 56 x 1/0.15 32 3.0 0.61 0.64 357
50 50.89 48 x 20 x 3/0.15 28 4.8 0.42 0.44 510
50 50.89 36 x 40 x 2/0.15 28 5.0 0.43 0.44 510
70 71.25 48 x 28 x 3/0.15 36 5.0 0.30 0.31 714
70 71.25 36 x 56 x 2/0.15 35 6.0 0.30 0.31 714
75 76.33 36 x 40 x 3/0.15 30 7.0 0.28 0.29 765
95 95.00 40 x 28 x 4/0.15 40 6.0 0.23 0.24 950
120 118.74 48 x 28 x 5/0.15 42 7.0 0.18 0.19 1187