Discipline Group Product/Material of test Specific Test Performed Test method Range of Testing/Limit of detection (@±)MU Test Performed at

Mechanical Building Material Bitumen (Industrial) Loss on Heating IS 1212: 1978 0.01 % to 5 % 0.07 % @0.09% Permanent Facility

Bitumen (Polymer Modified


Mechanical Building Material Loss in Mass IS 9382: 1979 0.01 % to 5 % 0.07 % @0.09% Permanent Facility
Bitumen)

Mechanical Building Material Bitumen (Industrial/Paving) Ductility IS 1208: 1978 0.0 cm to 100 cm 3.81 cm@96.6 cm Permanent Facility

Mechanical Building Material Bitumen (Industrial/Paving) Penetration Test IS 1203: 1978 1 mm to 80 mm 2.54 mm @ 49.80mm Permanent Facility

Bitumen (Industrial/Paving/Polymer
Mechanical Building Material Flash Point IS 1209: 1978 200⁰C to 350⁰C 15.05 oC@ 314.0 Permanent Facility
Modified Bitumen)

Bitumen (Industrial/Paving/Polymer
Mechanical Building Material Softening Point IS 1205: 1978 40 ⁰C to 180⁰C 2.14 oC@ 53.9 oC Permanent Facility
Modified Bitumen)

Absolute Viscosity at 60 deg.


Mechanical Building Material Bitumen (Paving) ASTM D 4402: 2015 800 poise to 6000 poise 38.86 poise@ 1852poise Permanent Facility
C

Kinematic Viscosity at 135


Mechanical Building Material Bitumen (Paving) ASTM D 4402: 2015 100 cSt to 1000 cSt 17.24 cSt @ 451.6cSt Permanent Facility
deg.C

Mechanical Building Material Bitumen (Paving) Solubility in Trichloroethylene IS 1216: 1978 70 % to 100 % 1.45 % @99.55% Permanent Facility

Viscosity by Saybolt Furol


Mechanical Building Material Bitumen Emulsion IS 3117: 2004 10 Second to 250 Second 1.15Second @ 26.4Second Permanent Facility
Viscometer at 25 deg. C

Viscosity by Saybolt Furol


Mechanical Building Material Bitumen Emulsion IS 3117: 2004 10 Second to 400 Second 2.19Second @ 19.4Second Permanent Facility
Viscometer at 50 deg. C

Mechanical Building Material Bituminous Mix/Core Bitumen Content ASTM D 2172: 2017 2 % to 18 % 0.13 % @5.26% Permanent Facility

Density by Nuclear density


Mechanical Building Material Bituminous Mix/Core Permanent Facility
gauge

Thickness of Bituminous
Mechanical Building Material Bituminous Mix/Core Permanent Facility
Layer

Bricks/Heavy Duty Burnt Clay


Mechanical Building Material Building Bricks/Pulverized Fuel Compressive Strength IS 3495 (Part I): 2019 2 N/mm2 to 25 N/mm2 0.88 N/mm2@ 10.82N/mm2 Permanent Facility
Ash-Lime Bricks
Discipline Group Product/Material of test Specific Test Performed Test method Range of Testing/Limit of detection (@±)MU Test Performed at

Bricks/Heavy Duty Burnt Clay


Dimensions (Common Burnt 1.51-2.78mm @ 1540.6-
Mechanical Building Material Building Bricks/Pulverized Fuel IS 1077: 1992 20 mm to 5000 mm Permanent Facility
Clay Building Bricks) 4643.6 mm
Ash-Lime Bricks

Bricks/Heavy Duty Burnt Clay


0.62-0.74mm @ 70.71-231.66
Mechanical Building Material Building Bricks/Pulverized Fuel Dimensions (Heavy Duty) IS 2180: 1988 30 mm to 310 mm Permanent Facility
mm
Ash-Lime Bricks

Bricks/Heavy Duty Burnt Clay


Dimensions (Pulverized Fuel 1.51-2.79mm @ 1540.6-
Mechanical Building Material Building Bricks/Pulverized Fuel IS 12894: 2002 20 mm to 5000 mm Permanent Facility
Ash-Lime Bricks) 4643.6 mm
Ash-Lime Bricks

Bricks/Heavy Duty Burnt Clay


Mechanical Building Material Building Bricks/Pulverized Fuel Efflorescence IS 3495 (Part III): 2019 Qualitative @ Permanent Facility
Ash-Lime Bricks

Bricks/Heavy Duty Burnt Clay


Mechanical Building Material Building Bricks/Pulverized Fuel Water Absorption IS 3495 (Part II): 2019 0.1 % to 30 % 0.74 % @13.41% Permanent Facility
Ash-Lime Bricks

Mechanical Building Material Paver Block Compressive Strength IS 15658 (Annexure D): 2006 2 N/mm2 to 25 N/mm2 0.88 N/mm2@ 10.82N/mm2 Permanent Facility

Mechanical Building Material Paver Block Abrasion Resistance IS 15658 (Annexure E): 2006 2 N/mm2 to 25 N/mm2 0.88 N/mm2@ 10.82N/mm2 Permanent Facility

Mechanical Building Material Paver Block Dimesnsions IS 15658 (Annexure B): 2006 2 N/mm2 to 25 N/mm2 0.88 N/mm2@ 10.82N/mm2 Permanent Facility

Mechanical Building Material Paver Block Thickness of Wearing Layer IS 15658 : 2006 2 N/mm2 to 25 N/mm2 0.88 N/mm2@ 10.82N/mm2 Permanent Facility

Mechanical Building Material Paver Block Water Absorption IS 15658 (Annexure C): 2006 2 N/mm2 to 25 N/mm2 0.88 N/mm2@ 10.82N/mm2 Permanent Facility

Mechanical Building Material Cement Compressive Strength IS 4031 (Part 6): 1988 10 N/mm2 to 70 N/mm2 3.71N/mm2 @ 35.7N/mm2 Permanent Facility

Mechanical Building Material Cement Consistency IS 4031 (Part 4): 1988 10 % to 35 % 1.57 % @28.76% Permanent Facility

Mechanical Building Material Cement Density IS 4031 (Part 11):1988 2 gm/cc to 4 gm/cc 0.01 gm/cc @ 2.84 gm/cc Permanent Facility

Mechanical Building Material Cement Fineness Test (Dry) IS 4031 (Part 1): 1996 1 % to 30 % 0.56 % @2.13% Permanent Facility

Fineness Test by Blaine Air


Mechanical Building Material Cement IS 4031 (Part 2): 1999 100 m2/kg to 500 m2/kg 10.13m2/kg @ 338.2m2/kg Permanent Facility
Permeability Method
Discipline Group Product/Material of test Specific Test Performed Test method Range of Testing/Limit of detection (@±)MU Test Performed at

Initial Setting Time/Final


Mechanical Building Material Cement IS 4031 (Part 5): 1988 10 Minute to 800 Minute 13.91Minute @ 230 Minute Permanent Facility
Setting Time

Mechanical Building Material Cement Soundness by Autoclave IS 4031 (Part 3): 1988 0.01 % to 2 % 0.02 % @0.04% Permanent Facility

Soundness by Le- Chatelier


Mechanical Building Material Cement IS 4031 (Part 3): 1988 0.1 mm to 10 mm 0.37 mm @ 0.9 mm Permanent Facility
Method

Mechanical Building Material Cement Concrete Flooring Tile Flatness IS 1237: 2012 0.01 mm to 10 mm 0.11 mm @ 0.71mm Permanent Facility

Mechanical Building Material Cement Concrete Flooring Tile Perpendicularity IS 1237: 2012 0.01 % to 5 % 0.08 % @ 0.22% Permanent Facility

Mechanical Building Material Cement Concrete Flooring Tile Straightness IS 1237: 2012 0.0 % to 5 % 0.02 % @0.16% Permanent Facility

Mechanical Building Material Cement Concrete Flooring Tile Water Absorption IS 1237: 2012 0.1 % to 20 % 0.78 % @5.85% Permanent Facility

Mechanical Building Material Cement Concrete Flooring Tile Wet Transverse Strength IS 1237: 2012 1 N/mm2 to 10 N/mm2 0.39N/mm2 @3.7 N/mm2 Permanent Facility

Mechanical Building Material Ceramic Tile/Vitrified Tiles Rectangularity IS 13630 (Part 1):2019 0.01 % to 5 % 0.06 % @0.3% Permanent Facility

Mechanical Building Material Ceramic Tile/Vitrified Tiles Straightness IS 13630 (Part 1): 0.0 % to 5 % 0.07 % @0.22% Permanent Facility

Mechanical Building Material Ceramic Tile/Vitrified Tiles Water Absorption IS 13630 (Part 2): 0.1 % to 20 % 0.64 % @5.36% Permanent Facility

Mechanical Building Material Chequered Cement Concrete Tile Flatness IS 13801: 2013 0.01 mm to 10 mm 0.13 mm @ 0.66 Permanent Facility

Mechanical Building Material Chequered Cement Concrete Tile Perpendicularity IS 13801: 2013 0.01 % to 5 % 0.08 % @ 0.25% Permanent Facility

Mechanical Building Material Chequered Cement Concrete Tile Straightness IS 13801: 2013 0.00 % to 5 % 0.06 % @0.22% Permanent Facility

Mechanical Building Material Chequered Cement Concrete Tile Water Absorption IS 13801: 2013 0.1 % to 20 % 0.56 % @7.04% Permanent Facility
Discipline Group Product/Material of test Specific Test Performed Test method Range of Testing/Limit of detection (@±)MU Test Performed at

Mechanical Building Material Coarse Aggregate / Ballast Bulk Density IS 2386 (Part III): 1963 1 kg/L to 4 kg/L 0.02 kg/L @ 1.56 kg/L Permanent Facility

Mechanical Building Material Coarse Aggregate / Ballast Elongation Index IS 2386 (Part I): 1963 5 % to 70 % 1.34 % @ Permanent Facility

Mechanical Building Material Coarse Aggregate / Ballast Flakiness Index IS 2386 (Part I): 1963 5 % to 70 % 1.59 % @ Permanent Facility

Mechanical Building Material Coarse Aggregate / Ballast Impact Value IS 2386 (Part IV): 1963 5 % to 60 % 2.00 % @ 21 % Permanent Facility

Mechanical Building Material Coarse Aggregate / Ballast Los Angeles Abrasion Value IS 2386 (Part IV): 1963 5 % to 70 % 1.67 % @ Permanent Facility

Mechanical Building Material Coarse Aggregate / Ballast Sieve Analysis (Gradation) IS 2386 (Part I): 1963 0.1 % to 100 % 1.26 % @ 100-0.23 Permanent Facility

Mechanical Building Material Coarse Aggregate / Ballast Specific Gravity IS 2386 (Part III): 1963 2to 4 0.04@ Permanent Facility

Mechanical Building Material Coarse Aggregate / Ballast Stripping Value IS 6241: 1971 1 % to 100 % 5.10 % @ 68 % Permanent Facility

Mechanical Building Material Coarse Aggregate / Ballast Water Absorption IS 2386 (Part III): 1963 0.2 % to 20 % 0.02 % @ Permanent Facility

Mechanical Building Material Concrete Compressive Strength (Core) IS 516 (Part IV): 2018 5 N/mm2 to 80 N/mm2 4.31 N/mm2@ 28.78N/mm2 Permanent Facility

Mechanical Building Material Concrete Compressive Strength (Cube) IS 516: 1959 5 N/mm2 to 80 N/mm2 0.57 N/mm2@ 29.31N/mm2 Permanent Facility

Mechanical Building Material Concrete Flexural Strength IS 516: 1959 1 N/mm2to 10 N/mm2 0.28 N/mm2@ 4.11N/mm2 Permanent Facility

Workability by Compacting
Mechanical Building Material Concrete IS 1199 (Part-II):2018 0.75to 1 0.01@0.93 Permanent Facility
Factor

Mechanical Building Material Concrete Workability by Slump Test IS 1199 (Part-II):2018 0.00 mm to 250 mm 6.78 mm @ 108 mm Permanent Facility

Mechanical Building Material Concrete Density of Fresh Concrete IS 1199 (Part-II):2018 0.00 mm to 250 mm 6.78 mm @ 108 mm Permanent Facility
Discipline Group Product/Material of test Specific Test Performed Test method Range of Testing/Limit of detection (@±)MU Test Performed at

Mechanical Building Material Concrete Density of Harden Concrete IS 1199 (Part-II):2018 0.00 mm to 250 mm 6.78 mm @ 108 mm Permanent Facility

Mechanical Building Material Concrete Flow value IS 1199 (Part-II):2018 0.00 mm to 250 mm 6.78 mm @ 108 mm Permanent Facility

Mechanical Building Material Fine Aggregate Bulk Density IS 2386 (Part III): 1963 1 kg/L to 4 kg/L 0.03 kg/L @ 1.73 kg/L Permanent Facility

Mechanical Building Material Fine Aggregate Bulking IS 2386 (Part III): 1963 10 % to 35 % 1.414 % @ 30 % Permanent Facility

Mechanical Building Material Fine Aggregate Sieve Analysis (Gradation) IS 2386 (Part I): 1963 0.1 % to 100 % 4.50 % @ 95.2-2.87% Permanent Facility

Mechanical Building Material Fine Aggregate Fineness Modulus IS 2386 (Part I): 1963 0.1 % to 100 % 4.50 % @ 95.2-2.87% Permanent Facility

Mechanical Building Material Fine Aggregate Specific Gravity IS 2386 (Part III): 1963 2to 4 0.04@2.61 Permanent Facility

Mechanical Building Material Fine Aggregate Water Absorption IS 2386 (Part III): 1963 0.2 % to 20 % 0.04 % @0.44% Permanent Facility

Steel Bars, High Strength Deformed


Mechanical Building Material Bend Test IS 1599: 2012 Qualitative @ PermanentFacility
Steel Bars & Reinforcement Coupler

Steel Bars, High Strength Deformed Nominal Mass (Weight per


Mechanical Building Material IS 1786: 2008 0.090 Kg/m to 10 Kg/m 0.01 Kg/m @ 1.44 Kg/m PermanentFacility
Steel Bars & Reinforcement Coupler meter)

Steel Bars, High Strength Deformed


Mechanical Building Material Re-bend Test IS 1786: 2008 Qualitative @ PermanentFacility
Steel Bars & Reinforcement Coupler

Steel Bars, High Strength Deformed


Mechanical Building Material Tensile Strength IS 1608 (Part-1): 2018 20 N/mm2 to 750 N/mm2 11.31 N/mm2 @ 645.26 N/mm2 PermanentFacility
Steel Bars & Reinforcement Coupler

Steel Bars, High Strength Deformed


Mechanical Building Material Yield Stress/0.2% Proof Stress IS 1608 (Part-1): 2018 200 N/mm2 to 700 N/mm2 18.34 N/mm2 @ 525.90 N/mm2 PermanentFacility
Steel Bars & Reinforcement Coupler

Steel Bars, High Strength Deformed


Mechanical Building Material Shear Test 18.34 N/mm2 @ 525.90 N/mm2 PermanentFacility
Steel Bars & Reinforcement Coupler

Deflection Measurement of
Mechanical Soil & Rock Field Testing Pavement using Benkelman IRC 81: 1997 0 mm to 10 mm 0.16 mm @ 1.06 SiteFacility
Beam Deflection Test
Discipline Group Product/Material of test Specific Test Performed Test method Range of Testing/Limit of detection (@±)MU Test Performed at

Deflection Measurement of
Mechanical Soil & Rock Field Testing Pavement using falling weight IRC 81: 1997 0.16 mm @ 1.06 SiteFacility
deflectometer

Measurement of Surface
Mechanical Soil & Rock Field Testing Roughness by Fifth Wheel IRC SP 16 : 2019 500 mm/km to 5000 mm/km 172.05mm/km @ 1920mm/km SiteFacility
Bump Integrator

California Bearing Ratio


Mechanical Soil & Rock Soil IS 2720 (Part 16):1987 1 % to 100 % 0.90 % @11% Permanent Facility
(CBR)

Grain Size Analysis ( Dry


Mechanical Soil & Rock Soil IS 2720 (Part-IV): 1985 0.1 % to 100 % 2.15 % @ 100-26.01% Permanent Facility
Sieve Analysis )

Grain Size Analysis


Mechanical Soil & Rock Soil IS 2720 (Part IV): 1985 0.1 % to 90 % 1.41 % @7.36% Permanent Facility
(Hydrometer Method)

Grain Size Analysis (Wet


Mechanical Soil & Rock Soil IS 2720 (Part IV): 1985 0.1 % to 100 % 3.04 % @ 87.22-17.65% Permanent Facility
Sieve Analysis)

Heavy Compaction Test (Dry


Mechanical Soil & Rock Soil IS 2720 (Part VIII): 1983 1 g/cc to 3 g/cc 0.03 g/cc @ 1.84 g/cc Permanent Facility
Density)

Heavy Compaction Test


Mechanical Soil & Rock Soil IS 2720 (Part VIII): 1983 5 % to 30 % 0.76 % @10.8% Permanent Facility
(Moisture Content)

Light Compaction Test (Dry


Mechanical Soil & Rock Soil IS 2720 (Part-7):1980 1 g/ml to 3 g/ml 0.02 g/ml @ 1.65 g/ml Permanent Facility
Density)

Light Compaction Test


Mechanical Soil & Rock Soil IS 2720 (Part VII): 1980 5 % to 30 % 0.66 % @15% Permanent Facility
(Moisture Content)

Unconfined Compressive
Mechanical Soil & Rock Soil IS 2720 (Part 10):1991 0.5 kg/cm2 to 25 kg/cm2 0.22 kg/cm2 @ 4.46kg/cm2 Permanent Facility
Strength

Mechanical Soil & Rock Soil Water Content IS 2720 (Part II): 1973 0.50 % to 30 % 0.06 % @0.59% Permanent Facility

Dry Density of Soils In-place,


Mechanical Soil & Rock Soil Testing (Field) IS 2720 (Part XXIX): 1975 1.0 g/cm3 to 2.0 g/cm3 0.03 g/cm3@ 1.644g/cm3 SiteFacility
by Core- Cutter Method

Dry Density of Soils In-place,


Mechanical Soil & Rock Soil Testing (Field) by the Sand Replacement IS 2720 (Part XXVIII): 1974 1.0 g/cm3 to 2.5 g/cm3 0.06 g/cm3 @ 2.224 g/cm3 SiteFacility
Method

Rapid Determination of Water


Mechanical Soil & Rock Soil Testing (Field) Content from the Gas Pressure IS 2720 (Part II)Section 5: 1973 1 % to 30 % 0.49 % @4.6% SiteFacility
using Calcium Carbide
Discipline Group Product/Material of test Specific Test Performed Test method Range of Testing/Limit of detection (@±)MU Test Performed at

Mechanical Soil & Rock Soil Testing (Field) Field CBR IS 2720 (Part 31) 1 % to 30 % 0.49 % @4.6% SiteFacility

Mechanical Soil & Rock Soil Testing (Field) Standard Penetration Test IS 2131: 1981 1 N-Value to 100 N- Value 3.69 N- Value @ 21 N- Value SiteFacility

Mechanical Soil & Rock Soil Liquid Limit IS 2720 (Part 5): 1985 10 % to 600 % 0.67 % @22.5% Permanent Facility

Mechanical Soil & Rock Soil Plastic Limit IS 2720 (Part 5) :1985 10 % to 150 % 1.52 % @ 14 % Permanent Facility

Mechanical Soil & Rock Soil Specific Gravity IS 2720 (Part III) Sec1/2: 1980 1to 3 0.07@2.62 Permanent Facility

Mechanical Soil & Rock Soil Organic Content Permanent Facility

Dynamic Cone Penetrometer


Mechanical Soil & Rock Soil Permanent Facility
Test

Road Marking thickness by


Mechanical Building Material Thermoplast Permanent Facility
Thickness Gauge

Luminance for Thermoplastic


Mechanical Building Material Thermoplast Road Markings by Retro Permanent Facility
Reflectometer

Coefficient of Retro Reflection


Mechanical Building Material Sign Board for Traffic Signage by Retro Permanent Facility
Reflectometer

Building Materials -
Half Cell Potential Difference
NDT Reinforced Concrete Reinforced Concrete Structure ASTM C 876: 2015 -0.1 Volt to -1 Volt V-0.02 Volt @ @ -0.1792 volt SiteFacility
Test
Structures

Building Materials -
NDT Reinforced Concrete Reinforced Concrete Structure Rebound Hammer Test IS 13311 (Part II): 1992 10 Mpa to 70 Mpa 2.33 Mpa @ 27.6 Mpa SiteFacility
Structures

Building Materials -
NDT Reinforced Concrete Reinforced Concrete Structure Ultrasonic Pulse Velocity Test IS 516 (Part 5, Sec I): 2018 1 km/sec to 6 km/sec 0.5km/sec @ 5.72 km/sec SiteFacility
Structures

Building Materials - Compressive Strength of


NDT Reinforced Concrete Reinforced Concrete Structure Concrete by Cut and Pull out ASTM C 900:19 0.0 to 100 kN SiteFacility
Structures Tester (CAPO)

Building Materials -
NDT Reinforced Concrete Reinforced Concrete Structure Cover Depth SiteFacility
Structures
Discipline Group Product/Material of test Specific Test Performed Test method Range of Testing/Limit of detection (@±)MU Test Performed at

Building Materials -
NDT Reinforced Concrete Reinforced Concrete Structure Spacing of Reinforcement Bar
Structures
Building Materials -
Diameter of Reinforcement
NDT Reinforced Concrete Reinforced Concrete Structure
Bar
Structures
Job Mix formula for GSB
Job Mix formula for WMM
Job Mix formula for BM,SDBC,DBM,BC
Concrete Mix design for various Grades

Design of Crust overlay for flexible Pavement by BBD and falling Weight Deflectometer
Design for new flexible pavement as per IRC 37
Design for Concrete Pavement

You might also like