You are on page 1of 2

Mix 

design for M25
Report No. TC‐701522000002003

Project : Huhtamaki Pvt. Ltd.
Client : M.S. Global Builder
Date Of Sample Reciept: 05/07/2022
Date Of Casting: 15/07/2022
Stipulations for proportioning
Grade Designation : 25 (Reinforced Concrete)
Type Of Cement : Ambuja PPC (Confirming to IS 1489)
Exposure Condition : Moderate
Workability : 150 mm (Slump)
Maximum Nominal Size Of 
Aggregate : 20 mm

Maximum Water‐cement 
0.38
Ratio :
Minimum Cement Content: 300 kg/cum
Type Of Aggregate : Sub‐Angular
Chemical Admixture Type : Anuvi Chemicals Resikon Supermax 5

Test data of Matarials
Aggregate
Size  Properties
M.C. % Water Absorption Specific Gravity Sieve  Required adjustment in water content Sample ID
Coarse (20mm) 2.45 2.88 2.73 0.43 20220707228
Coarse (10mm) 10.37 4.6 2.64 ‐5.77 20220707229
Fine 5.7 5.49 2.49 ‐0.21 20220707227
Cement Specific  Consistency IST FST Fineness Compressive Srength (days) Sample ID
Ambuja PPC (Confirming to IS  3 41.13
3.16 33% 165 MIN. 230 MIN. 0.148 7 43.41 2022070230
1489)
28 57.5
Admixture Properties Sample ID
Sp. Gravity
Anuvi Chemicals Resikon  2022070266
1.06
Supermax 5
Micro Silica Properties Sample ID
Sp. Gravity
‐‐
0

Target Strength (f'ck) 31.6 N/mm2

W/C Ratio 0.39 <  0.50 (W/C ratio required for moderate exposure for Reinforced Concrete as per IS 456 Table 5


< 0.5 (Tender Condition of Client's Project)
hence O.K
Water Content 150 198 Ltr. (for 100mm Slump as per Section 4.2 IS 10262:2009)
140  Ltr. (Reduced 10 kg as per clause 4.2 for sub‐angular aggregates)
148.4  Ltr. (for 100mm Slump as per Section 4.2 IS 10262:2009)
150  Ltr. (considering Plastisizer will reduce water demand by 25%)
Water Content 165  Ltr.
Cement Content 400 kg/cum
400 > 300 kg/cum (cement content Rquired for modserate  eposure for Plain Concrete as per IS 456 table 5

Proportion of Coarse and Fine 
For Water Cement Ratio 0.50 and Fine aggragt of grading Zone 1 with nominal size of agggregtes 20mm is 0.60
Aggregates
                           coarse 0.54 (no adjustment made wrt w/c ratio)
0.54 (Based On Experience the Volume of coarse aggregate has been reduced for better workability and strength)
Proportion of 20 mm aggregate 0.27
Proportion of 10 mm aggregate 0.27
Fine 0.46
Mix Calculation
Volume Of concrete 1.00 cum
Volume Of Cement 0.13 cum
Volume Of Water 0.15 cum
Volume of Superplasticizer 0.004 cum 1.1 % by weight of Cement
Volume of Total (all in) Aggregates 0.72 cum

Weight of Coarse Aggregates (20mm) 530.28
kg

Weight of Coarse Aggregates (10mm) 512.80
kg
Weight Of fine Aggregates 824.02 kg
Weight Of Superplasticiser 4.4 kg
Weight of Accelerator 0 kg
Mix Proportion for Trial
For 1 cum in 
SSD  Water Adjustment for Moisture 
Actual Quantities (kg) For 0.035 cum (kg)
Condition  Content and Absorption
(kg)
cement 400.00 400.00 14.00 1.0
Water 165.00 135.96 ‐29.04 4.76 0.4
Fine Aggregates 824.02 825.75 28.90 2.1
Coarse Aggregates 20mm 530.28 528.00 18.48 1.3
Coarse Aggregates 10mm 512.80 542.39 18.98 1.3
Superplasticiser 4.40 4.40 0.15 0.0110
Water Cement ratio 0.41 0.34 0.34
Time Sample ID
Workability Slump 
0 min 30 min 1 hr. 2 hr. 2022070231
110 mm
Cube Compressive Strength
Age Of Testing Strength Sample ID
28 hours (ACT Method) 14.23 2022070231

7 days ‐ 17.77 2022070231

28 days ‐ 32.26 2022070231

Authorized Signatory Authorized Signatory


Sandip Deshpande Dr. Yogini Deshpande
Technical Manager Quality Manager