Professional Documents
Culture Documents
A A
B
ML40P CONTROL PANEL CONNECTION, B
C C
D D
Version : 2.26
Standard : EN81-20
Date of Update : 28.5.2019
E E
Important Note : These schemes are advisory. Mikrolift reserves the right to change schemes. Our company cannot be held
responsible for any changes made by persons other than those within our company.
F F
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
R
S
A T A
N
PE
UPS_P_UNFUSE
UPS_P
UPS_N
4A
FKR1 ED_220AC_N
B 6A B
ED_220AC_P
F4 IN OUT F5
..P P.. EARTH
..N UPS N..
100
30mA 1000
2A
GROUND FAULT
PROTECTED F8
AUTOMAT FUSE 220V AC 24V DC BRIDGE
4A
220V AC +
AC
20V AC F9
-
C DC C
35A / 1000V
Main Transformator
RC Filter
CRL-P:2-CR:10B
NC1
RUPS-P:2-CR:10B
KP RKP-P:2-CR:10B
Kups
D D
4A
GROUP WOTOMAT
RC Filter
F11
NC1
Kups xxxx-P:xx-CR:xxx
KP
GW1
Sayfa Numarası
Page Number
K-NOTR
PE
NOTR
K220
Title : Main
Power and UPS Connection
L1 L2 L3 N PE
For Electrical Lifts
F TO CAR WIRING F
Project: ML40P_v2 Revision: 1
R
S
A T A
N
PE
UPS_P_UNFUSE
UPS_P
UPS_N
4A
FKR2 ED_220AC_N
B F13 B
6A ED_220AC_P
IN OUT F14
..P P.. EARTH
..N UPS N..
100
30mA 1000
2A
GROUND FAULT
PROTECTED F16
AUTOMAT FUSE 220V AC 24V DC BRIDGE
4A
220V AC +
AC
20V AC F17
-
C DC C
35A / 1000V
Main Transformator
D D
4A
GROUP WOTOMAT
F18
xxxx-P:xx-CR:xxx
GW2
Sayfa Numarası
Page Number
PE
K-NOTR
NOTR
K220
Title : Main
Power and UPS Connection
L1 L2 L3 N PE
For Hydraulic Lifts
F F
TO CAR WIRING Project: ML40P_v2 Revision: 1
R
S
A T A
N
PE
RCx-P:2-CR:10B
UPS_AKU(-)
UPS_AKU(+)
UPS_P
UPS_N
FKR8 ED_220AC_N
B B
4A ED_220AC_P
F47 EARTH
I1
I2
(-)
(+)
1000
100
AKÜ 30mA 1000
BATTERY 2A
GROUND FAULT
MLPOWER PROTECTED
AUTOMAT FUSE F49
220V AC 24V DC BRIDGE
4A
ÇIKIŞ GİRİŞ 220V AC +
OUTPUT INPUT AC
N
F50
L
20V AC
-
C DC C
35A / 1000V
Main Transformator
RC Filter
6A
F51
CRL-P:2-CR:10B
NC1
RUPS-P:2-CR:10B
KP RKP-P:2-CR:10B
Kups
D D
4A
RC Filter
GROUP WOTOMAT
5 x 12V / 7Ah
-+ -+ -+ -+ -+
F52
NC1
Kups xxxx-P:xx-CR:xxx
KP
GW3
F54 6A
Sayfa Numarası
Page Number
K-NOTR
PE
NOTR
K220
Title : Main
Power and MLPOWER Connection
L1 L2 L3 N PE
For Electrical Lifts
F F
TO CAR WIRING Project: ML40P_v2 Revision: 1
R
S
A T A
N
PE
UPS_AKU(-)
UPS_AKU(+)
UPS_P
UPS_N
FKR9 ED_220AC_N
B B
4A ED_220AC_P
F55 EARTH
(-)
(+)
100
AKÜ 30mA 1000
BATTERY 2A
GROUND FAULT
60VDC-UPS PROTECTED
AUTOMAT FUSE F57
220V AC 24V DC BRIDGE
4A
ÇIKIŞ GİRİŞ 220V AC +
OUTPUT INPUT AC
N
F58
L
20V AC
-
C DC C
35A / 1000V
Main Transformator
4A
RC Filter
6A
F59
F60
CRL-P:2-CR:10B
NC1
RUPS-P:2-CR:10B
KP RKP-P:2-CR:10B
Kups
D D
RC Filter
GROUP WOTOMAT
5 x 12V / 7Ah
-+ -+ -+ -+ -+
NC1
Kups xxxx-P:xx-CR:xxx
KP
GW4
F62 6A
Sayfa Numarası
Page Number
K-NOTR
PE
NOTR
K220
R
S
A T A
N
PE
UPS_P_UNFUSE
UPS_P
UPS_N
4A
FKR10 ED_220AC_N
B F63 6A B
ED_220AC_P
IN OUT F64
..P P.. EARTH
UPS
MAIN BRAKER
..N N..
100
30mA 1000
2A
GROUND FAULT
PROTECTED F67
24V DC BRIDGE
AKS1
20V AC F68
-
C DC C
35A / 1000V
Main Transformator
GW5
CURRENT PROTECTION
RC Filter
3 PHASE LEAK
FKR11
RC Filter
FKR12
F74
NC1
6A
Kups xxxx-P:xx-CR:xxx
KP
A1 PULSE
E CURRENT Bağlantı İsmi Sutun Satır Koordinatı E
A2 SWITCH Connection Name Column Row Coordinate
Sayfa Numarası
Page Number
K-NOTR
3
3S
NS
PE
NOTR
K220
Title : Main
Power and UPS Connections For
L1 L2 L3 N PE WELL WELL
LIGHTING LIGHTING Machine Roomless (MRL) Panel ( For Electical Lifts )
F BUTTON LAMPS F
Project: ML40P_v2 Revision: 1
TO CAR WIRING
Date: 28.5.2019 Sheet: 1e www.mikrolift.com
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
R
S
A T A
N
PE
RCx-P:2-CR:10B
UPS_AKU(-)
UPS_AKU(+)
UPS_P
UPS_N
FKR13 ED_220AC_N
B B
4A ED_220AC_P
I1
I2
(-)
(+)
1000
AKÜ F76 EARTH
BATTERY 100
30mA 1000
MLPOWER GROUND FAULT 2A
PROTECTED
ÇIKIŞ GİRİŞ AUTOMAT FUSE F78
OUTPUT INPUT 220V AC 24V DC BRIDGE
4A
N
N
L
220V AC +
AC
F80 20V AC F79
-
C 6A DC C
4A
35A / 1000V
Main Transformator
MAIN BRAKER
RC Filter
F82
5 x 12V / 7Ah
-+ -+ -+ -+ -+
AKS2
CRL-P:2-CR:10B
NC1
RUPS-P:2-CR:10B
PANEL FUSE
KP RKP-P:2-CR:10B
F83 6A Kups
D D
GW6
CURRENT PROTECTION
RC Filter
FKR14
WELL AND CAR F86
3 PHASE LEAK
LEAK CURRENT 6A
NC1
FKR15
PROTECTION
Kups xxxx-P:xx-CR:xxx
KP
A1
3S
NS
PE
NOTR
K220
Title : Main
Power And MLPOWER Connections For
L1 L2 L3 N PE WELL WELL
LIGHTING LIGHTING Machine Roomless (MRL) Panel ( For Electical Lifts )
F BUTTON LAMPS F
TO CAR WIRING
Project: ML40P_v2 Revision: 1
R
S
A T A
N
PE
UPS_AKU(-)
UPS_AKU(+)
UPS_P
UPS_N
(-)
(+)
AKÜ FKR16 ED_220AC_N
B BATTERY B
4A ED_220AC_P
EARTH
60VDC-UPS F89
100
ÇIKIŞ GİRİŞ 30mA 1000
OUTPUT INPUT 2A
GROUND FAULT
N
N
L
L
PROTECTED
AUTOMAT FUSE F91
220V AC 24V DC BRIDGE
4A
F92 6A 220V AC +
AC
20V AC F93
MAIN BRAKER
-
C DC C
5 x 12V / 7Ah 35A / 1000V
Main Transformator
-+ -+ -+ -+ -+
AKS3
RC Filter
4A
PANEL FUSE
KP RKP-P:2-CR:10B
Kups
D D
F97 6A
3 PHASE LEAK
RC Filter
FKR17
FKR18
F100 NC1
6A Kups xxxx-P:xx-CR:xxx
KP
Title : Main
Power And 60VDC-UPS Connections For
K-NOTR
3
3S
NS
PE
NOTR
K220
A A
UPS_P UPS_P
UPS_N UPS_N
3A
F146
LR-P
LR-N
B B
BR-P
BR-N
C C
D D
E E
A A
UPS_P UPS_P
UPS_N UPS_N
3A
F147
LR-P
220V AC
70V AC
LR-N
B B
BR-P
BR-N
Brake Transformator
C C
D D
E E
A A
UPS_P UPS_P
UPS_N UPS_N
3A
F148
LR-P
LR-N
220V AC
70V AC
B B
BR-P
BR-N
Cam & Brake Transformator
C C
D D
E E
A A
UPS_P UPS_P
UPS_N UPS_N
3A
F149
LR-P
LR-N
220V AC
55V AC
B B
BR-P
BR-N
Cam Transformator
220V AC
70V AC
C C
Brake Transformator
D D
E E
A A
UPS_P UPS_P
UPS_N UPS_N
3A
F150
LR-P
220V AC
55V AC
LR-N
B B
BR-P
BR-N
Brake Transformator
C C
D D
E E
A A
UPS_P UPS_P
UPS_N UPS_N
3A
F151
LR-P
LR-N
220V AC
70V AC
B B
BR-P
BR-N
Cam Transformator
220V AC
55V AC
C C
Brake Transformator
D D
E E
A A
UPS_P UPS_P
UPS_N UPS_N
3A
F152
LR-P
LR-N
220V AC
55V AC
B B
BR-P
BR-N
Cam & Brake Transformator
C C
D D
E E
A A
TO CONTROL
PANEL
L1
L3
L2
PE
B B
MAIN BRAKER
FKR26
AKS4
F153 6A
FKR27
CURRENT PROTECTION
C C
PULSE
3 PHASE LEAK
A1 CURRENT
SWITCH
A2
L1
L3
L2
PE
3S
NS
PE
NOTR
D D
MAIN LINE WELL WELL
LIGHTING LIGHTING TO CAR WIRING
BUTTON LAMPS
E E
R-P:1x-CR:10A R-P:1x-CR:10A
S-P:1x-CR:10A S-P:1x-CR:10A
A T-P:1x-CR:10A T-P:1x-CR:10A A
N-P:1x-CR:10A N-P:1x-CR:10A
PE-P:1x-CR:10A PE-P:1x-CR:10A
100-P:1x-CR:10B 100-P:1x-CR:10B
1000-P:1x-CR:10B 1000-P:1x-CR:10B
RCOM
RU2 RC1
RU1 RC2
S4 RC3
S3 RC4
S2 CRL
B S1 RKP B
11 RUPS
10B
RX1
140
RX2
135
RD1
130
RD2
120
RB1
10A
RB2
130F
OSG1
S1
RU1
RC1
RX1
RD1
RB1
11
S3
RC3
S2
RU2
RC2
RX2
RD2
RB2
S
MP
RKP
RUPS
T
S4
RC4
CRL
R
RCOM
OSG2
C KXO1 15V C
KXO2 10B GND
140 A
PG3 135 -A
PG4 130 B
PG5 120 -B
PG6 10A
MLD
PG7
KRC
HRF 130F
DHG OSG1 LCD PTC
OSG2 1000
KXO1 100
D KXO2 ML40P_v2 SO D
ENTER
xxxx-P:xx-CR:xxx
DHG
KRC
HRF
PG3
PG4
PG5
PG6
PG7
KN1 KN2 KN3 ESC
Bağlantı İsmi Sutun Satır Koordinatı
Connection Name Column Row Coordinate
Sayfa Numarası
Flat Cable 16 Flat Cable 16 Flat Cable 16
1000
P1
P2
P3
P4
P5
P6
Page Number
100
E E
CANH-P:16-CR:9B
CANL-P:16-CR:9B
ML1-P:18-CR:1A
ML2-P:18-CR:1A Motor PTC Well PTC Machine
Room PTC
CANL
CANH
500P
501P
869P
ML2
ML1
F F
YAN
ML2
ML1
DEP
2BC
PG2
PG1
X15
X13
X08
X05
X03
X16
X14
X12
X10
X09
X07
X06
X04
X02
X01
X11
818
032
031
Project: ML40P_v2
500
870
869
817
501
SD
Revision: 1
SC
2G
02
A
G
B
C
E
F
A A
UPS_P-P:1x-CR:10B UPS_P-P:1x-CR:10B
UPS_N-P:1x-CR:10B UPS_N-P:1x-CR:10B
100-P:1x-CR:10B 100-P:1x-CR:10B
1000-P:1x-CR:10B 1000-P:1x-CR:10B
OSG1-P:2-CR:1C
OSG2-P:2-CR:1C
HRF-P:2-CR:1D
B NO2 B
KXO1-P:2-CR:1C
KX1
KXO2-P:2-CR:1C
NO2 NO3
130-P:2-CR:1B
KF KF
130F-P:2-CR:1C
C C
4A
F7
OSG SELENOID BRIDGE
D D
35A / 1000V
AC
DC
xxxx-P:xx-CR:xxx
+
-
HBR2
BK1
BK2
OSG OSG
Selenoid Selenoid
NC Contact
A A
UPS_P-P:1x-CR:10B UPS_P-P:1x-CR:10B
UPS_N-P:1x-CR:10B UPS_N-P:1x-CR:10B
100-P:1x-CR:10B 100-P:1x-CR:10B
1000-P:1x-CR:10B 1000-P:1x-CR:10B
OSG1-P:2-CR:1C
OSG2-P:2-CR:1C
HRF-P:2-CR:1D
B NO2 B
KXO1-P:2-CR:1C
KX1
KXO2-P:2-CR:1C
NO2 NO3
130-P:2-CR:1B
220V AC
KF KF
130F-P:2-CR:1C
C 28V AC C
4A
F114
OSG SELENOID BRIDGE
D D
35A / 1000V
AC
DC
xxxx-P:xx-CR:xxx
+
-
HBR2
BK1
BK2
OSG OSG
Selenoid Selenoid
NC Contact
A A
UPS_N-P:1x-CR:10B UPS_N-P:1x-CR:10B
SG_P-P:5x-CR:1B
B B
SET RESET
C C
SG-R
SG-S
D N D
xxxx-P:xx-CR:xxx
A1 A2 A1 A2
Bağlantı İsmi Sutun Satır Koordinatı
Connection Name Column Row Coordinate
Set Selenoid Reset Selenoid
Sayfa Numarası
Page Number
E E
OVERSPEED GOVERNOR
A A
UPS_N-P:1x-CR:10B UPS_N-P:1x-CR:10B
SG_P-P:5x-CR:1B
-
DC
+
AC
B 35A / 1000V B
SET RESET
C C
SG-R
SG-S
N
D D
xxxx-P:xx-CR:xxx
A1 A2 A1 A2
Bağlantı İsmi Sutun Satır Koordinatı
Connection Name Column Row Coordinate
Set Selenoid Reset Selenoid
Sayfa Numarası
Page Number
E E
OVERSPEED GOVERNOR
Title : Remote
Control For Overspeed Governor
(For 190VDC Coil)
F F
Project: ML40P_v2 Revision: 1
UPS_AKU(+)-P:1C-CR:10B
UPS_AKU(-)-P:1C-CR:10B UPS_P-P:1x-CR:10B
UPS_N-P:1x-CR:10B
A 100-P:1x-CR:10B 100-P:1x-CR:10B A
1000-P:1x-CR:10B 1000-P:1x-CR:10B
PE-P:1x-CR:10A
ED_220AC_N-P:1x-CR:10B NC1 NC1 NC1
KRC-P:2-CR:1D
ED_220AC_P-P:1x-CR:10B KF KX1 KX2
DHG-P:2-CR:1D
S2-P:2-CR:1B
R-P:1x-CR:10A
S4-P:2-CR:1B
S-P:1x-CR:10A
S1-P:2-CR:1B
T-P:1x-CR:10A
RU2-P:2-CR:1B
PE-P:1x-CR:10A
RU1-P:2-CR:1B
30mA FKR19 11-P:2-CR:1B
LR-N-P:1hx-CR:10B
B GROUND FAULT LR-P-P:1hx-CR:10B B
PROTECTED RD1-P:2-CR:10B
AUTOMAT FUSE RD2-P:2-CR:10B
F103 10A
PE
L3
L2
L1
BR-N-P:1hx-CR:10B
BR-P-P:1hx-CR:10B
10A-P:2-CR:1C
LINE
FILTER Kups
10B-P:2-CR:1C
AC1 140-P:2-CR:1C
PE
L3
L2
L1
NO1
RMB1
RMB2
RFO
RFCOM
AC2 RC Filter
KP
KX1
KF
S2 RX1-P:2-CR:10B
C R S6 RX2-P:2-CR:10B C
S1
NO1
S NO1 RC Filter
RSC
T Kups
MLDRIVER
UP
NO1
DOWN KX1 (1*)
PE COM
KX2
ENB RC Filter
W
U
V
B
P
PI KF (1*)
35A / 1000V
35A / 1000V
CAM BRIDGE
KX2 (1*)
AC
AC
NO2 NO2
DC
DC
KX1 KX2
110-P:6x-CR:2A
KX2
+
+
-
KF (2*)
KF (2*)
E xxxx-P:xx-CR:xxx E
B1
B2
2000
Sayfa Numarası
810
840
UPS_AKU(+)-P:1C-CR:10B
UPS_AKU(-)-P:1C-CR:10B UPS_P-P:1x-CR:10B
UPS_N-P:1x-CR:10B
A 100-P:1x-CR:10B 100-P:1x-CR:10B A
1000-P:1x-CR:10B 1000-P:1x-CR:10B
PE-P:1x-CR:10A
ED_220AC_N-P:1x-CR:10B NC1 NC1 NC1
KRC-P:2-CR:1D
ED_220AC_P-P:1x-CR:10B KF KX1 KX2
DHG-P:2-CR:1D
S2-P:2-CR:1B
R-P:1x-CR:10A
S4-P:2-CR:1B
S-P:1x-CR:10A
S1-P:2-CR:1B
T-P:1x-CR:10A
RU2-P:2-CR:1B
PE-P:1x-CR:10A
RU1-P:2-CR:1B
30mA 11-P:2-CR:1B
FKR20
B GROUND FAULT B
LR-N-P:1hx-CR:10B
PROTECTED LR-P-P:1hx-CR:10B
10A F109 AUTOMAT FUSE RD1-P:2-CR:10B
PE
L3
L2
L1
RD2-P:2-CR:10B
10A-P:2-CR:1C
LINE
FILTER Kups
10B-P:2-CR:1B
NO1
AC1
PE
L3
L2
L1
RMB1
RMB2
RFO
RFCOM
AC2 RC Filter
KP
S2
C R S6 C
KF
S1 RC Filter
S NO1
RSC
T Kups
MLDRIVER
UP
DOWN KX1 (1*)
PE COM
ENB RC Filter
W
U
V
B
P
PI KF (1*)
Control Panel
Emergency
RX2-P:2-CR:10B
D Stop Button D
35A / 1000V
KX1 NO2 NO2
CAM BRIDGE
KX2 (1*)
AC
110-P:6x-CR:2A
+
-
KX2
2001
810
E E
1* Contactors must be of AC-3 class with 220VAC coils!
KX1 (2*) KX2 (2*) RC filters must connected across the coils of contactors!
Door Lock
Magnet Coil
2* These contacts must be the main contact of contactor!
xxxx-P:xx-CR:xxx
W1
U1
V1
B1
B2
Bağlantı İsmi Sutun Satır Koordinatı Title : MLDRIVER and Contactors Connection
Synchronous Motor Coil Connection Name Column Row Coordinate
Brake For Gearless Machine
F Resistance Sayfa Numarası F
Page Number Project: ML40P_v2 Revision: 1
UPS_AKU(+)-P:1C-CR:10B
BR-N-P:1hx-CR:10B
UPS_AKU(-)-P:1C-CR:10B
BR-P-P:1hx-CR:10B
A 100-P:1x-CR:10B 100-P:1x-CR:10B A
1000-P:1x-CR:10B 1000-P:1x-CR:10B
PE-P:1x-CR:10A
ED_220AC_N-P:1x-CR:10B NC1 NC1 NC1
KRC-P:2-CR:1D
ED_220AC_P-P:1x-CR:10B KF KX1 KX2
DHG-P:2-CR:1D
S1-P:2-CR:1B
R-P:1x-CR:10A
S2-P:2-CR:1B
S-P:1x-CR:10A
S3-P:2-CR:1B
T-P:1x-CR:10A
S4-P:2-CR:1B
PE-P:1x-CR:10A
RU2-P:2-CR:1B
30mA RU1-P:2-CR:1B
FKR6
11-P:2-CR:1B
B GROUND FAULT LR-N-P:1hx-CR:10B B
PROTECTED LR-P-P:1hx-CR:10B
10A F26 AUTOMAT FUSE RD1-P:2-CR:10B
PE
L1
L3
L2
RD2-P:2-CR:10B
10A-P:2-CR:1C
110-P:6x-CR:2A
LINE
FILTER
Kups
Kups 1N4007
140-P:2-CR:1B
1N4007 Control Panel 10B-P:2-CR:1B
PE
L3
L2
L1
NO1
Emergency
1N4007 RC Filter RX1-P:2-CR:10B
Stop Button
KX1
NO1
RX2-P:2-CR:10B
C1
100
1000
RHO
RFO
RHA
RFA
C KP 1N4007 C
V0
R V1 RC Filter
V2
S
ADRIVE
KF
V3
T UP
NO1
DOWN KX1 (1*)
PE EN
15 NO2 NO2
B1
B2
KX2
RC Filter
W
U
V
35A / 1000V
35A / 1000V
KX2 (1*)
AC
AC
DC
DC
KX2
+
+
-
- KF (2*)
KF (2*)
E E
W1
U1
V1
B1
B2
2000
810
840
Speed Resistance
Coil 2* These contacts must be the main contact of contactor!
Door Lock Mechanical
Magnet Coil Brake Coil
xxxx-P:xx-CR:xxx
Title : ADrive
and Contactors Connection
Bağlantı İsmi Sutun Satır Koordinatı
Connection Name Column Row Coordinate
For Geared Machine
F Sayfa Numarası F
Page Number Project: ML40P_v2 Revision: 1
UPS_AKU(+)-P:1C-CR:10B
LR-N-P:1hx-CR:10B
UPS_AKU(-)-P:1C-CR:10B
LR-P-P:1hx-CR:10B
A 100-P:1x-CR:10B 100-P:1x-CR:10B A
1000-P:1x-CR:10B 1000-P:1x-CR:10B
PE-P:1x-CR:10A
ED_220AC_N-P:1x-CR:10B NC1 NC1 NC1
KRC-P:2-CR:1D
ED_220AC_P-P:1x-CR:10B KF KX1 KX2
DHG-P:2-CR:1D
S1-P:2-CR:1B
R-P:1x-CR:10A
S2-P:2-CR:1B
S-P:1x-CR:10A
S3-P:2-CR:1B
T-P:1x-CR:10A
S4-P:2-CR:1B
PE-P:1x-CR:10A
RU2-P:2-CR:1B
30mA RU1-P:2-CR:1B
FKR7
11-P:2-CR:1B
B GROUND FAULT B
PI-P:13-CR:1A
PROTECTED
AUTOMAT FUSE RD1-P:2-CR:10B
10A F32
RD2-P:2-CR:10B
PE
L3
L2
L1
10A-P:2-CR:1C
110-P:6x-CR:2A
LINE
FILTER Kups
Kups
1N4007
1N4007 Control Panel 10B-P:2-CR:1B
PE
L3
L2
L1
NO1
Emergency RC Filter
1N4007
Stop Button
RX2-P:2-CR:10B
C1
100
1000
RHO
RFO
RHA
RFA
C KP 1N4007 C
V0
R V1 RC Filter
KF
V2
S
T
ADRIVE V3
UP
DOWN KX1 (1*)
PE EN
15 NO2 NO2 RC Filter
X-ENC
D 4 Cable D
CAM BRIDGE
35A / 1000V
KX2 (1*)
AC
KX1 X-ENC DC
ENCABIT
24V
+
-
PI1
PI2
PI3
X-ENC1
KX2
15 Cable
E E
xxxx-P:xx-CR:xxx
B24V
BRM
T1
T2
810
Title : ADrive
U1
V1
UPS_AKU(+)-P:1C-CR:10B
UPS_AKU(-)-P:1C-CR:10B
A 100-P:1x-CR:10B 100-P:1x-CR:10B A
1000-P:1x-CR:10B 1000-P:1x-CR:10B
PE-P:1x-CR:10A
ED_220AC_N-P:1x-CR:10B NC1 NC1 NC1
KRC-P:2-CR:1D
ED_220AC_P-P:1x-CR:10B KF KX1 KX2
DHG-P:2-CR:1D
S2-P:2-CR:1B
R-P:1x-CR:10A
S4-P:2-CR:1B
S-P:1x-CR:10A
S1-P:2-CR:1B
T-P:1x-CR:10A
RU2-P:2-CR:1B
PE-P:1x-CR:10A
RU1-P:2-CR:1B
30mA 11-P:2-CR:1B
FKR30
LR-N-P:1hx-CR:10B
B GROUND FAULT LR-P-P:1hx-CR:10B B
PROTECTED RD1-P:2-CR:10B
AUTOMAT FUSE RD2-P:2-CR:10B
F172 10A
PE
L3
L2
L1
BR-N-P:1hx-CR:10B
BR-P-P:1hx-CR:10B
10A-P:2-CR:1C
LINE RB1-P:2-CR:10C
FILTER Kups RB2-P:2-CR:10C
10B-P:2-CR:1C
PE
L3
L2
L1
NO1
NO1 RC Filter 140-P:2-CR:1C
KP
KX1
KF
Kups
30B
30C
Y5C
Y5A
CM
X8
C R RX1-P:2-CR:10B C
X5
RX2-P:2-CR:10B
NO1
S X4 RC Filter
X3
T FUJI X2
INVERTER X1
NO1
REV
PE KX1 (1*)
FWD
KX2
PLC RC Filter
CMY
EN
B1
B2
W
KF (1*)
U
V
35A / 1000V
35A / 1000V
CAM BRIDGE
AC
AC
NO2
KX2 (1*)
DC
DC
110-P:6x-CR:2A
KX1
KX2
+
+
-
RB relay assignment should be selected as "Low Speed". Connection Name Column Row Coordinate
U1
V1
B1
B2
2001
2000
810
840
Sayfa Numarası
High Brake Page Number
Speed Resistance Door Lock Mechanical
Coil Magnet Coil Brake Coil
Title : Fuji
Inverter and Contactors Connection
For Geared Machine
F F
Project: ML40P_v2 Revision: 1
UPS_AKU(+)-P:1C-CR:10B
UPS_AKU(-)-P:1C-CR:10B
A 100-P:1x-CR:10B 100-P:1x-CR:10B A
1000-P:1x-CR:10B 1000-P:1x-CR:10B
PE-P:1x-CR:10A
ED_220AC_N-P:1x-CR:10B NC1 NC1 NC1
KRC-P:2-CR:1D
ED_220AC_P-P:1x-CR:10B KF KX1 KX2
DHG-P:2-CR:1D
S2-P:2-CR:1B
R-P:1x-CR:10A
S4-P:2-CR:1B
S-P:1x-CR:10A
S1-P:2-CR:1B
T-P:1x-CR:10A
RU2-P:2-CR:1B
PE-P:1x-CR:10A
RU1-P:2-CR:1B
30mA FKR29 11-P:2-CR:1B
LR-N-P:1hx-CR:10B
B GROUND FAULT LR-P-P:1hx-CR:10B B
PROTECTED RD1-P:2-CR:10B
AUTOMAT FUSE RD2-P:2-CR:10B
F166 10A
PE
L3
L2
L1
BR-N-P:1hx-CR:10B
BR-P-P:1hx-CR:10B
10A-P:2-CR:1C
LINE
FILTER Kups
10B-P:2-CR:1C
140-P:2-CR:1C
PE
L3
L2
L1
NO1
RC Filter
KP
KX1
KF
X4 RX1-P:2-CR:10B
M1
M3
MC
MB
C L1 X3 RX2-P:2-CR:10B C
X5
NO1
L2 NO1 RC Filter
X6
L3 Kups
SUMPO
X1
NO1
X2 KX1 (1*)
PE P-
KX2
X8 RC Filter
PB
P+
W
U
V
KF (1*)
35A / 1000V
35A / 1000V
CAM BRIDGE
KX2 (1*)
AC
AC
NO2 NO2
DC
DC
KX1 KX2
110-P:6x-CR:2A
KX2
+
+
-
KF (2*)
KF (2*)
E xxxx-P:xx-CR:xxx E
B1
B2
2000
Sayfa Numarası
810
840
UPS_AKU(+)-P:1C-CR:10B
UPS_AKU(-)-P:1C-CR:10B
A 100-P:1x-CR:10B 100-P:1x-CR:10B A
1000-P:1x-CR:10B 1000-P:1x-CR:10B
PE-P:1x-CR:10A
ED_220AC_N-P:1x-CR:10B NC1 NC1 NC1
KRC-P:2-CR:1D
ED_220AC_P-P:1x-CR:10B KF KX1 KX2
DHG-P:2-CR:1D
S2-P:2-CR:1B
R-P:1x-CR:10A
S4-P:2-CR:1B
S-P:1x-CR:10A
S1-P:2-CR:1B
T-P:1x-CR:10A
RU2-P:2-CR:1B
PE-P:1x-CR:10A
RU1-P:2-CR:1B
30mA 11-P:2-CR:1B
FKR31
B GROUND FAULT B
LR-N-P:1hx-CR:10B
PROTECTED LR-P-P:1hx-CR:10B
10A F174 AUTOMAT FUSE RD1-P:2-CR:10B
PE
L3
L2
L1
RD2-P:2-CR:10B
10A-P:2-CR:1C
LINE
FILTER Kups
10B-P:2-CR:1B
NO1
PE
L3
L2
L1
RC Filter
KP
X4
M1
M3
MC
MB
C L1 X3 C
KF
X5 RC Filter
L2 NO1
X6
L3 Kups
SUMPO
X1
X2 KX1 (1*)
PE P-
X8 RC Filter
PB
P+
W
U
V
KF (1*)
Control Panel
Emergency
RX2-P:2-CR:10B
D Stop Button D
35A / 1000V
KX1 NO2 NO2
CAM BRIDGE
KX2 (1*)
AC
KX1 KX2
DC
110-P:6x-CR:2A
+
-
KX2
2001
810
E E
1* Contactors must be of AC-3 class with 220VAC coils!
KX1 (2*) KX2 (2*) RC filters must connected across the coils of contactors!
Door Lock
Magnet Coil
2* These contacts must be the main contact of contactor!
xxxx-P:xx-CR:xxx
W1
U1
V1
B1
B2
Bağlantı İsmi Sutun Satır Koordinatı Title : SUMPO Inverter and Contactors Connection
Synchronous Motor Coil Connection Name Column Row Coordinate
Brake For Gearless Machine
F Resistance Sayfa Numarası F
Page Number Project: ML40P_v2 Revision: 1
PGx-P:2-CR:1C
HRF-P:2-CR:1D
UPS_N-P:1x-CR:10B
A UPS_P-P:1x-CR:10B A
100-P:1x-CR:10B
PI-P:4x-CR:1A
NOTE : If “Brake Tracing-2” assignment is not made
140-P:2-CR:1B
to programmable inputs, brake tracing contacts must
RX1-P:2-CR:10B
be connected in series to “HRF” input.
4A
EMERGENCY
RESCUE SWITCH
A B F36
B B
SG_P-P:3x-CR:1A (2*)
NO3
NO2
WORKING PUSH
WORKING PUSH
1. MECHANICAL BRIDGE
BUTTON 1
KF
KF
BUTTON 2
( Normal Working )
35A / 1000V
DC
AC
DC
+
-
C C
RC Filter RC Filter
KX1
+
-
NO1
KX2
KS1 (1*) KS2 (1*)
NO1
D D
KS1 KS2
2000B
2000A
points with subdividing, a safer test run can be made.
FCA1
FCB1
FCA2
FCB2
840B
840A
FEEDBACK FEEDBACK
COIL COIL
NC CONTACT NC CONTACT
PGx-P:2-CR:1C
HRF-P:2-CR:1D
UPS_N-P:1x-CR:10B
A UPS_P-P:1x-CR:10B A
100-P:1x-CR:10B
220V AC
PI-P:4x-CR:1A
NOTE : If “Brake Tracing-2” assignment is not made
140-P:2-CR:1B
to programmable inputs, brake tracing contacts must
RX1-P:2-CR:10B
be connected in series to “HRF” input.
28V AC
4A
EMERGENCY
RESCUE SWITCH
A B F116
B B
SG_P-P:3x-CR:1A (2*)
NO3
NO2
WORKING PUSH
WORKING PUSH
1. MECHANICAL BRIDGE
BUTTON 1
KF
KF
BUTTON 2
( Normal Working )
35A / 1000V
DC
AC
DC
+
-
C C
RC Filter RC Filter
KX1
+
-
NO1
KX2
KS1 (1*) KS2 (1*)
NO1
D D
KS1 KS2
2000B
2000A
points with subdividing, a safer test run can be made.
FCA1
FCB1
FCA2
FCB2
840B
840A
FEEDBACK FEEDBACK
COIL COIL
NC CONTACT NC CONTACT
PGx-P:2-CR:1C
HRF-P:2-CR:1D
UPS_N-P:1x-CR:10B
A UPS_P-P:1x-CR:10B A
100-P:1x-CR:10B
220V AC
PI-P:4x-CR:1A
NOTE : If “Brake Tracing-2” assignment is not made
140-P:2-CR:1B
to programmable inputs, brake tracing contacts must
RX1-P:2-CR:10B
be connected in series to “HRF” input.
55V AC
4A
EMERGENCY
RESCUE SWITCH
A B F120
B B
SG_P-P:3x-CR:1A (2*)
NO3
NO2
WORKING PUSH
WORKING PUSH
1. MECHANICAL BRIDGE
BUTTON 1
KF
KF
BUTTON 2
( Normal Working )
35A / 1000V
DC
AC
DC
+
-
C C
RC Filter RC Filter
KX1
+
-
NO1
KX2
KS1 (1*) KS2 (1*)
NO1
D D
KS1 KS2
2000B
2000A
points with subdividing, a safer test run can be made.
FCA1
FCB1
FCA2
FCB2
840B
840A
FEEDBACK FEEDBACK
COIL COIL
NC CONTACT NC CONTACT
PGx-P:2-CR:1C
HRF-P:2-CR:1D
UPS_N-P:1x-CR:10B
A UPS_P-P:1x-CR:10B A
100-P:1x-CR:10B
220V AC
PI-P:4x-CR:1A
NOTE : If “Brake Tracing-2” assignment is not made
140-P:2-CR:1B
to programmable inputs, brake tracing contacts must
RX1-P:2-CR:10B
be connected in series to “HRF” input.
70V AC
4A
EMERGENCY
RESCUE SWITCH
A B F124
B B
SG_P-P:3x-CR:1A (2*)
NO3
NO2
WORKING PUSH
WORKING PUSH
1. MECHANICAL BRIDGE
BUTTON 1
KF
KF
BUTTON 2
( Normal Working )
35A / 1000V
DC
AC
DC
+
-
C C
RC Filter RC Filter
KX1
+
-
NO1
KX2
KS1 (1*) KS2 (1*)
NO1
D D
KS1 KS2
2000B
2000A
points with subdividing, a safer test run can be made.
FCA1
FCB1
FCA2
FCB2
840B
840A
FEEDBACK FEEDBACK
COIL COIL
NC CONTACT NC CONTACT
BPS1-P:8x-CR:1A
BPS2-P:8x-CR:1A
120-P:2-CR:1B
A 130-P:2-CR:1B A
135-P:2-CR:1B
119A
117A
119A
111A
113B
119B
117B
119B
111B
111C
140-P:2-CR:1B
120
137
135
140
135
130
120
110
116
116
118
118
110
PE
PE-P:7-CR:xB
120-P:7-CR:xB
MACHINE
ROOM
NC1 NC1 NC1 130-P:7-CR:xB
NC1
135-P:7-CR:xB
B B
DBK YBK HRK
MYSB KUYUKK
GASB
WELL
NC1
RUN
USKK
RKMS
GACB
RUN
GA TOP OF THE CAR
RKCB
C RA C
119A
119B
120
135
137
140
118
869K
YHB
501
500
869
RVY
869P AHB
NC1 NC1 NC1 NC1 NC1 NC1 501
RECALL HAND TERMINAL 500
PK KLKK KCKK KGHK STOP AKK BKK
100 RVA
TOP OF THE CAR
D HAND TERMINAL D
KY2
3S
NS
100
870
AL
PKR1 116
PKR2 119A
PKR5 111C
KDCB RUN PKR4 (FOR HYDRAULIC SYSTEMS) RKMS : TOP OF THE CAR INSPECTION EMERGENCY STOP BUTTON
HRK : OVERSPEED GOVERNOR CONTACT RA : TOP OF THE CAR INSPECTION CONTACT
870
100
AL
12
3 NS PE KTK : BUFFER CONTACT RKCB : TOP OF THE CAR INSPECTION RUN BUTTON
E PKR5 KATK : COUNTER WEIGHT BUFFER CONTACT RVY : TOP OF THE CAR INSPECTION UP BUTTON E
PIT
ASKK : PIT END LIMIT SWITCH CONTACT RVA : TOP OF THE CAR INSPECTION DOWN BUTTON
USKK : ULTIMATE LIMIT SWITCH CONTACT KDMS : PIT EMERGENCY STOP BUTTON
112A
112A
113A
112B
111C
KY1
KY2
114
114
115
115
116
KDRA 870
3S
KCKK : CAR TOP COVER CONTACT KDA : PIT INSPECTION DOWN BUTTON
KGHK : CAR SLACK ROPE CONTACT KDCB : PIT INSPECTION RUN BUTTON
501
P.S.:IF THERE IS A CONTACT NOT USED IN SAFETY CIRCUIT, IT MUST BE BRIDGED
KDY
Title : Safety Circuit Connections -1-
100
F NC1 NC1 NC1 NC1 NC1 F
500
KDA Project: ML40P_v2 Revision: 2
HRKGK HPVK KTK KATK ASKK
Date: 28.5.2019 Standard :EN81-20
Sheet: 6a www.mikrolift.com
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
BPS1-P:8x-CR:1A
BPS2-P:8x-CR:1A
120-P:2-CR:1B
A 130-P:2-CR:1B A
135-P:2-CR:1B
119A
117A
119A
111A
113B
119B
117B
119B
111B
111C
140-P:2-CR:1B
120
137
135
140
135
130
120
110
116
116
118
118
110
PE
PE-P:7-CR:xB
120-P:7-CR:xB
MACHINE
ROOM
NC1 NC1 NC1 130-P:7-CR:xB
NC1
135-P:7-CR:xB
B B
DBK YBK HRK
MYSB KUYUKK
GASB
WELL
NC1
RUN
USKK
RKMS
GACB
RUN
GA TOP OF THE CAR
RKCB
C RA C
119A
119B
120
135
137
140
118
869K
YHB
501
500
869
RVY
869P AHB
NC1 NC1 NC1 NC1 NC1 NC1 501
RECALL HAND TERMINAL 500
PK KLKK KCKK KGHK STOP AKK BKK
100 RVA
TOP OF THE CAR
D HAND TERMINAL D
119B ASKK : PIT END LIMIT SWITCH CONTACT RVA : TOP OF THE CAR INSPECTION DOWN BUTTON
USKK : ULTIMATE LIMIT SWITCH CONTACT KDMS : PIT EMERGENCY STOP BUTTON
PK : OVERSPEED DETECTION CONTACT KDRA : PIT INSPECTION CONTACT
KDRA 870 KLKK : CAR LIMIT SWITCH CONTACT KDY : PIT INSPECTION UP BUTTON
KCKK : CAR TOP COVER CONTACT KDA : PIT INSPECTION DOWN BUTTON
KGHK : CAR SLACK ROPE CONTACT KDCB : PIT INSPECTION RUN BUTTON
112A
112A
113A
112B
111C
114
114
115
115
116
501
P.S.:IF THERE IS A CONTACT NOT USED IN SAFETY CIRCUIT, IT MUST BE BRIDGED
KDY
Title : Safety
Circuit Connections -1-
100
NC1 NC1 NC1 NC1 NC1
(Without MLKDK)
F 500 F
KDA Project: ML40P_v2 Revision: 2
HRKGK HPVK KTK KATK ASKK
Date: 28.5.2019 Standard :EN81-20
Sheet: 6b www.mikrolift.com
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
135-P:6x-CR:10B 135-P:6x-CR:10B
130-P:6x-CR:10B 130-P:6x-CR:10B
120-P:6x-CR:10B 120-P:6x-CR:10B
PE-P:6x-CR:10B PE-P:6x-CR:10B
B B
NC1
NC1
FK3
FLOOR 2
FK3
NC1
KK3
GND
DOOR
C GND C
DOOR
NC1
FK2
FLOOR 1
NC1
FK2
NC1
KK2
D D
GND
GND
DOOR DOOR
FLOOR 0
NC1
FK1
NC1
FK1
NC1
E E
KK1
GND
GND
DOOR DOOR
A A
MULTI STEPS CAM SWITCHES
140-P:2-CR:1B
135-P:2-CR:1B
130-P:2-CR:1B 0 1
120-P:2-CR:1B
BPS1-P:6x-CR:10A
BPS2-P:6x-CR:10A
2
100-P:1x-CR:10B
PGx-P:2-CR:1C 3
100 SCBO
D D
E E
Title : Safety
Circuit Bridging Box Scheme
For Only Car Door Automatic
F F
Project: ML40P_v2 Revision: 1
A
MULTI STEPS CAM SWITCHES A
140-P:2-CR:1B
130-P:2-CR:1B 0 1
120-P:2-CR:1B
BPS1-P:6x-CR:10A
BPS2-P:6x-CR:10A
2
100-P:1x-CR:10B
PGx-P:2-CR:1C 3
S0_NC1
S0_NC1 S0_NC2
BPS2 S1_NO S2_NO S1_NO
S2_NO
S3_NO
C
SAFETY CIRCUIT BRIDGING BOX C
(BYPASS UNIT)
CAUTION !
S0_NC2 These switches must be suitable to
EN 60947-5-1 standard.
100 SCBO
E E
CONTROL PANEL
K-NOTR
CANH
CANL
NOTR
K220
1000
2001
ML1
ML2
ALB
TL3
TL4
TL5
+12
100
810
817
818
869
PE
1
A A
12V / 1.2 Ah
SPEAKER
Dry Battery
NO
NO
CAM
Coil of the Door
ML1
ML2
B Lock Magnet B
SOCKET
TOP OF THE CAR
031
1
B
C
2BC
AKU-
D
E
032
+12
-12
ACIL
MLO
100
1000
2
AKU+
A
2G
M
~
FAN
MLSERI40
ALARM
COM DOOR
CANH
CANL
KAPA
CONTROL
EIN4
EIN1
EIN2
EIN3
GC4
GC3
GC2
GC1
OPEN
X01
X02
X03
X04
X05
X06
X07
X08
X09
X10
X12
X13
X14
X15
X16
K15
X11
E01
804
500
501
AC
CARD
K3
K5
CLOSE
C C
100
MOTOR NTC
M
NO
NO
GRAY-CODE
OUTPUTS
NO
NO
NO
NTC
AYK
KSR1
KSR2
RVA
RVY
AUTOMATIC DOOR
RA
YSM
ASM
DOOR BRIDGING
ALARM UNIT
D D
Intercom Button
OVER LOAD
a 12V / 2W
b a
IK16 ILIMUNATED
c
NOISE
2bc
d f b
2g g WARNING A B C D
e 24V / 2W EMERGENCY LAMP IKx : CAR CALL BUTTONS AND LAMP
UNIT
2bc
f e
d
c MINIMUM 5 LUX
NO AYK : OVERLOAD CONTACT INTERCOM UNIT
g KSR1 : DOWN LIMIT BI-STABLE SWITCH
2bc Common Anode (+) FAN SWITCH
INSIDE THE CAR
2g Display
KSR2 : UP LIMIT BI-STABLE SWITCH
ALARM RA : INSPECTION CONTACT
E RVA : DOWN INSPECTION BUTTON E
24V / 2W IK2 BUTTON
032 RVY : UP INSPECTION BUTTON
CAR LAMPS YSM : UP RE-LEVELING MONO-STABLE SWITCH
24V / 2W
OPEN CLOSE
ASM : DOWN RE-LEVELING MONO-STABLE SWITCH
24V / 2W ML1 : DOOR OPEN ZONE MONO STABLE SWITCH
BUTTON BUTTON
ML2 : DOOR OPEN ZONE MONO STABLE SWITCH
031 IK1 KKEK : CAR DOOR EXTRA SWITCH
NC
KKEK Title : Car
Wiring
24V / 2W
Serial Connection
F F
Project: ML40P_v2 Revision: 1
D
A
1
1
2
2
PE PE
869 869
EH4
EH3
EH2
EH1
ML1 ML1
ML2 ML2
817 817
818 818
3
3
: EXTRA LINE
: EXTRA LINE
1000 1000
TL3 TL3
TL5 TL5
CANH CANH
4
4
CANL CANL
1000 1000
100 100
ALB ALB
+12 +12
PE PE
5
5
1 1
NOTR NOTR
CONTROL PANEL
K220 K220
K-NOTR K-NOTR
6
6
EH3 EH3
EH4 EH4
118
Date: 28.5.2019
118
Title : Flexible
119A 119A
Project: ML40P_v2
119B 119B
7
7
Flexible Cable 32
120 120
137 137
135 135
Cable Connections
140 140
8
8
Sheet: 10
Revision: 1
9
9
10
10
www.mikrolift.com
F
E
C
B
D
A
1 2 3 4 5 6 7 8 9 10
+12V
119A
A A
119B
113B
111C
ALB
100
501
500
870
116
NS
PE
3S
3
CONTROL PANEL
MACHINE ROOM
B B
KY1
3
12
KY2
3S
NS
100
870
AL
PE
PKR3 119B
PKR4 113B
501K 501K
500K 500K
PKR1 116
PKR2 119A
PKR5 111C
PKR2
WELL
KDMS
MLKDK
PKR3
870
100
AL
12
3 NS PE
KDCB RUN PKR4
112A
112A
113A
112B
111C
KY1
KY2
100
114
114
115
115
116
PKR5
3S
3
SOCKET
KDRA 870
D D
501
KDY
+12V
ALB
119A
113B
119B
111C
870
501
500
100
116
A A
TO ELECTRIC PANEL CONTROL PANEL
NEUTRAL
MACHINE ROOM
PHASE
PE
B B
PKR3
113B
KDCB RUN PKR4
119A
PKR5
119B
KDRA
870 870
D D
112A
112A
113A
112B
111C
114
114
115
115
116
KDY 501 501
NO
WELL ALARM
WELL LIGHTING BUTTON 100 100
KEY SOCKET KDA NC1 NC1 NC1 NC1 NC1
500 500
HRKGK HPVK KTK KATK ASKK
E E
CONTROL PANEL
UP/DOWN MIX. COLLECTIVE UP (DOWN) COLLECTIVE SELECTIVE COLLECTIVE
A A
203 (303)
202 (302)
201 (301)
YAN
1000
1000
1000
1000
2BC
031
100
100
403
402
401
100
100
203
203
302
301
032
2G
02
G
B
F
24V / 2W
B SDS B
a
b DK3 DA3 (DY3) DA3
FLOOR 2
24V / 2W a
c
2bc
d f b
2g g
e
24V / 2W
2bc
f e c 24V / 2W 24V / 2W 24V / 2W
d
g
YK
2bc Common Anode (+)
2g Display
C C
24V / 2W
SDS
a DY2
b DK2 DA2 (DY2)
24V / 2W a
FLOOR 1
2bc
d f b
2g g
e 24V / 2W
24V / 2W
2bc
f e c 24V / 2W 24V / 2W
d
g
YK
2bc Common Anode (+)
DA2
2g Display
D D
24V / 2W
24V / 2W
SDS
a
b DK1 DA1 (DY1) DY1
24V / 2W a
c
2bc
d f b
2g g
e
FLOOR 0
24V / 2W
2bc
CALL CONNECTIONS
D
A
1
1
( 2 - 6 FLOORS )
( 2 - 8 FLOORS )
( 7 - 9 FLOORS )
( 2 - 8 FLOORS )
( 9 - 16 FLOORS )
( 2 - 16 FLOORS )
UP COLLECTIVE
UP COLLECTIVE
UP COLLECTIVE
( 9 - 16 FLOORS )
( 10 - 16 FLOORS )
( 17 - 24 FLOORS )
( 17 - 24 FLOORS )
( 17 - 24 FLOORS )
DOWN COLLECTIVE
DOWN COLLECTIVE
DOWN COLLECTIVE
2
2
SELECTIVE COLLECTIVE
SELECTIVE COLLECTIVE
SELECTIVE COLLECTIVE
UP / DOWN MIX COLLECTIVE
301 301 401 301 301 401 201 201 401 401 401 X01
3
3
302 302 402 302 302 402 202 202 402 402 402 X02
303 303 403 303 303 403 203 203 403 403 403 X03
304 304 404 304 304 404 204 204 404 404 404 X04
305 305 405 305 305 405 205 205 405 405 405 X05
306 306 406 306 306 406 206 206 406 406 406 X06
307 307 301 307 307 407 207 207 407 407 407 X07
308 308 302 308 308 408 208 208 408 408 408 X08
309 202 303 309 309 301 209 209 201 409 409 X09
4
4
310 203 304 310 310 302 210 210 202 410 410 X10
311 204 305 311 311 303 211 211 203 411 411 X11
CALL TERMINALS
312 205 202 312 312 304 212 212 204 412 412 X12
AT MLKLM40 BOARD
313 206 203 313 313 305 213 213 205 413 413 X13
314 207 204 314 314 306 214 214 206 414 414 X14
315 208 205 315 315 307 215 215 207 415 415 X15
209 206 316 316 308 216 216 208 416 416 X16
5
5
6
6
Title : Call
CALL TERMINALS
Date: 28.5.2019
AT 1st MLINT65 BOARD
Definitions
NOT USED
NOT USED
NOT USED
NOT USED
NOT USED
NOT USED
NOT USED
NOT USED
www.mikrolift.com
F
E
C
B
D
A
F
E
C
B
D
A
TOP OF THE CAR CONTROL PANEL
1
1
( 2 - 9 FLOORS )
( 2 - 9 FLOORS )
( 2 - 16 FLOORS )
( 2 - 16 FLOORS )
( 2 - 16 FLOORS )
( 2 - 16 FLOORS )
( 2 - 16 FLOORS )
( 2 - 16 FLOORS )
UP COLLECTIVE
UP COLLECTIVE
UP COLLECTIVE
UP COLLECTIVE
( 10 -16 FLOORS )
( 10 -16 FLOORS )
( 17 - 24 FLOORS )
( 17 - 24 FLOORS )
( 17 - 24 FLOORS )
( 17 - 24 FLOORS )
( 17 - 24 FLOORS )
( 17 - 24 FLOORS )
( 17 - 24 FLOORS )
( 17 - 24 FLOORS )
2
2
DOWN COLLECTIVE
DOWN COLLECTIVE
DOWN COLLECTIVE
DOWN COLLECTIVE
SELECTIVE COLLECTIVE
SELECTIVE COLLECTIVE
SELECTIVE COLLECTIVE
SELECTIVE COLLECTIVE
SELECTIVE COLLECTIVE
SELECTIVE COLLECTIVE
3
3
401 401 401 401 401 401 401 401 401 X01 301 301 301 301 301 201 201 401 401 X01
402 402 402 402 402 402 402 402 402 X02 302 302 302 302 302 202 202 402 402 X02
403 403 403 403 403 403 403 403 403 X03 303 303 303 303 303 203 203 403 403 X03
404 404 404 404 404 404 404 404 404 X04 304 304 304 304 304 204 204 404 404 X04
405 405 405 405 405 405 405 405 405 X05 305 305 305 305 305 205 205 405 405 X05
406 406 406 406 406 406 406 406 406 X06 306 306 306 306 306 206 206 406 406 X06
407 407 407 407 407 407 407 407 407 X07 307 307 307 307 307 207 207 407 407 X07
4
4
408 408 408 408 408 408 408 408 408 X08 308 308 308 308 308 208 208 408 408 X08
409 409 409 409 409 409 409 409 409 X09 309 309 202 309 309 209 209 409 409 X09
410 410 410 410 410 410 410 410 X10 310 310 203 310 310 210 210 410 410 X10
411 411 411 411 411 411 411 411 X11 311 311 204 311 311 211 211 411 411 X11
412 412 412 412 412 412 412 412 X12 312 312 205 312 312 212 212 412 412 X12
AT SERI40 BOARD
CALL TERMINALS
CALL TERMINALS
AT MLKLM40 BOARD
413 413 413 413 413 413 413 413 X13 313 313 206 313 313 213 213 413 413 X13
414 414 414 414 414 414 414 414 X14 314 314 207 314 314 214 214 414 414 X14
415 415 415 415 415 415 415 415 X15 315 315 208 315 315 215 215 415 415 X15
5
5
416 416 416 416 416 416 416 416 X16 316 209 316 316 216 216 416 416 X16
6
6
423 423 423 423 X07 207 207 323 223 423 X07
424 424 424 424 X08 208 208 324 224 424 X08
Title : Call X09 209 209 X09
X10 210 210 X10
Date: 28.5.2019
X11 211 211 X11
NOT USED
NOT USED
NOT USED
NOT USED
NOT USED
NOT USED
NOT USED
NOT USED
NOT USED
CALL TERMINALS
CALL TERMINALS
Project: ML40P_v2
X12 212 212 X12
X13 213 213 X13
AT 3rd MLINT65 BOARD
AT 1st MLINT65 BOARD
7
7
317 X01
318 X02
319 X03
320 X04
8
8
321 X05
322 X06
323 X07
X08
217
Sheet: 13b
X09
Revision: 1
218 X10
219 X11
NOT USED
NOT USED
NOT USED
NOT USED
NOT USED
NOT USED
NOT USED
NOT USED
CALL TERMINALS
220 X12
9
9
221
AT 2nd MLINT65 BOARD
X13
222 X14
223 X15
224 X16
10
10
www.mikrolift.com
F
E
C
B
D
A
1 2 3 4 5 6 7 8 9 10
UPS_P-P:1x-CR:10B UPS_P-P:1x-CR:10B
UPS_N-P:1x-CR:10B UPS_N-P:1x-CR:10B
A 100-P:1x-CR:10B 100-P:1x-CR:10B A
1000-P:1x-CR:10B 1000-P:1x-CR:10B
PE-P:1x-CR:10A
ED_220AC_N-P:1x-CR:10B
ED_220AC_P-P:1x-CR:10B NC1 NC1 NC1
KRC-P:2-CR:1D
KU2 KTR KST
RCOM-P:2-CR:10B
R-P:1x-CR:10A RC4-P:2-CR:10B
S-P:1x-CR:10A
T-P:1x-CR:10A 10A-P:2-CR:1C
110-P:6x-CR:2A
30mA FKR3 24VDC Relay
LR-N-P:1hx-CR:10B
B GROUND FAULT B
LR-P-P:1hx-CR:10B
PROTECTED RLIR
AUTOMAT FUSE 140-P:2-CR:1B
10B-P:2-CR:1B
RC Filter
11-P:2-CR:1B
Control Panel
NC2
Emergency
Stop Button KTR (1*) KST
RC Filter NO2
C CRL-P:2-CR:10B C
KU2
KTR KST NO1
RKP-P:2-CR:10B
KU2 NC2
RUPS-P:2-CR:10B
KST (1*) KTR
NO1
RLIR RC Filter
NO1
35A / 1000V
RC Filter
AC
DC
NO1
KU2
KA3 (1*) RA3a
+
-
RC Filter
NO1
E E
RDHa
KDH(1*) (2*)
1* Contactors must be of AC-3 class with 220VAC coils!
W1
W2
2001
U1
V1
U2
V2
UPS_P-P:1x-CR:10B UPS_P-P:1x-CR:10B
UPS_N-P:1x-CR:10B UPS_N-P:1x-CR:10B
A 100-P:1x-CR:10B 100-P:1x-CR:10B A
1000-P:1x-CR:10B 1000-P:1x-CR:10B
PE-P:1x-CR:10A
ED_220AC_N-P:1x-CR:10B
ED_220AC_P-P:1x-CR:10B NC1 NC1
KRC-P:2-CR:1D
KU2A KUAB
RCOM-P:2-CR:10B
R-P:1x-CR:10A RC4-P:2-CR:10B
S-P:1x-CR:10A
T-P:1x-CR:10A 10A-P:2-CR:1C
110-P:6x-CR:2A
30mA FKR25 24VDC Relay
LR-N-P:1hx-CR:10B
B GROUND FAULT B
LR-P-P:1hx-CR:10B
PROTECTED RLIR
AUTOMAT FUSE 140-P:2-CR:1B
10B-P:2-CR:1B
11-P:2-CR:1B
Control Panel
Emergency
Stop Button
RC Filter
C C
NO1
NO1
KU2A
KU2A (1*) RU2a
NO1
RLIR
KU2B (1*)
KU2A
RC Filter
D D
CAM BRIDGE
35A / 1000V
NO1
AC
DC
RC Filter
NO1
810
U
V
A A
RX1-P:2-CR:10B
FKR4 RX2-P:2-CR:10B
3A
140-P:2-CR:1B RD1-P:2-CR:10B
F43 RD2-P:2-CR:10B
220V AC
55V AC
+
B AC RB1-P:2-CR:10C B
30mA
RB2-P:2-CR:10C
-
10B-P:2-CR:1B GROUND FAULT DC
PROTECTED 35A / 1000V
PE-P:1x-CR:10A AUTOMAT FUSE 1000-P:1x-CR:10B
1N4007
RU2-P:2-CR:1B
RU2a 24VDC Relay
C 1N4007 C
NO NO
KA3 KDH
S3-P:2-CR:1B
RA3a 24VDC Relay
1N4007
S4-P:2-CR:1B
RDHa 24VDC Relay
D D
Valve Test
Button
VB
VC
L10
V10
VD
VA
E xxxx-P:xx-CR:xxx E
A3 Valve Valve Up Low Up High Down High Down Low Bağlantı İsmi Sutun Satır Koordinatı
Comman Speed Valve Speed Valve Speed Valve Speed Valve Connection Name Column Row Coordinate
Sayfa Numarası
Page Number
A A
RX1-P:2-CR:10B
FKR5 RX2-P:2-CR:10B
3A
140-P:2-CR:1B RD1-P:2-CR:10B
F45 RD2-P:2-CR:10B
220V AC
55V AC +
B AC RB1-P:2-CR:10C B
30mA
RB2-P:2-CR:10C
-
10B-P:2-CR:1B GROUND FAULT DC
PROTECTED 35A / 1000V
AUTOMAT FUSE 1000-P:1x-CR:10B
PE-P:1x-CR:10A 1N4007
RU2-P:2-CR:1B
RU2a 24VDC Relay
C 1N4007 C
NO
KA3
S3-P:2-CR:1B
RA3a 24VDC Relay
D D
Valve Test
Button
L10
V10
Vhs
Vdw
Vup
E xxxx-P:xx-CR:xxx E
A3 Valve Bağlantı İsmi Sutun Satır Koordinatı
Valve Up Direction High Speed Down Direction
Common Valve Valve Valve Connection Name Column Row Coordinate
Sayfa Numarası
Page Number
A A
RX1-P:2-CR:10B
FKR21 RX2-P:2-CR:10B
3A
140-P:2-CR:1B RD1-P:2-CR:10B
F143 RD2-P:2-CR:10B
220V AC
28V AC
+
B AC RB1-P:2-CR:10C B
30mA
RB2-P:2-CR:10C
-
10B-P:2-CR:1B GROUND FAULT DC
PROTECTED 35A / 1000V
PE-P:1x-CR:10A AUTOMAT FUSE 1000-P:1x-CR:10B
1N4007
RU2-P:2-CR:1B
RU2a 24VDC Relay
C 1N4007 C
NO NO
KA3 KDH
S3-P:2-CR:1B
RA3a 24VDC Relay
1N4007
S4-P:2-CR:1B
RDHa 24VDC Relay
D D
Valve Test
Button
VB
VC
L10
V10
VD
VA
E xxxx-P:xx-CR:xxx E
A3 Valve Valve Up Low Up High Down High Down Low Bağlantı İsmi Sutun Satır Koordinatı
Comman Speed Valve Speed Valve Speed Valve Speed Valve Connection Name Column Row Coordinate
Sayfa Numarası
Page Number
Title : Valves
Connections For Blain EV100 Hydraulic Unit
( Valve Voltage 24V DC )
F F
Project: ML40P_v2 Revision: 1
A A
RX1-P:2-CR:10B
FKR22 RX2-P:2-CR:10B
3A
140-P:2-CR:1B RD1-P:2-CR:10B
F131 RD2-P:2-CR:10B
220V AC
55V AC +
B AC RB1-P:2-CR:10C B
30mA
RB2-P:2-CR:10C
-
10B-P:2-CR:1B GROUND FAULT DC
PROTECTED 35A / 1000V
AUTOMAT FUSE 1000-P:1x-CR:10B
PE-P:1x-CR:10A 1N4007
RU2-P:2-CR:1B
RU2a 24VDC Relay
C 1N4007 C
NO
KA3
S3-P:2-CR:1B
RA3a 24VDC Relay
D D
Valve Test
Button
L10
VMP
V10
VML
VMD
E xxxx-P:xx-CR:xxx E
A3 Valve Bağlantı İsmi Sutun Satır Koordinatı
Valve Up Direction High Speed Down Direction
Common Valve Valve Valve Connection Name Column Row Coordinate
Sayfa Numarası
Page Number
A A
RX1-P:2-CR:10B
FKR23 RX2-P:2-CR:10B
3A
140-P:2-CR:1B RD1-P:2-CR:10B
F133 RD2-P:2-CR:10B
220V AC
55V AC +
B AC RB1-P:2-CR:10C B
30mA
RB2-P:2-CR:10C
-
10B-P:2-CR:1B GROUND FAULT DC
PROTECTED 35A / 1000V
AUTOMAT FUSE 1000-P:1x-CR:10B
PE-P:1x-CR:10A 1N4007
RU2-P:2-CR:1B
RU2a 24VDC Relay
C 1N4007 C
NO
KA3
S3-P:2-CR:1B
RA3a 24VDC Relay
D D
Valve Test
Button
L10
EVS
V10
EVD
E EVR xxxx-P:xx-CR:xxx E
A3 Valve Bağlantı İsmi Sutun Satır Koordinatı
Valve Up Direction High Speed Down Direction
Common Valve Valve Valve Connection Name Column Row Coordinate
Sayfa Numarası
Page Number
A A
RX1-P:2-CR:10B
FKR24 RX2-P:2-CR:10B
3A
140-P:2-CR:1B
F139
220V AC
55V AC +
B AC RB1-P:2-CR:10C B
30mA
RB2-P:2-CR:10C
-
10B-P:2-CR:1B GROUND FAULT DC
PROTECTED 35A / 1000V
AUTOMAT FUSE 1000-P:1x-CR:10B
PE-P:1x-CR:10A 1N4007
RU2-P:2-CR:1B
RU2a 24VDC Relay
C 1N4007 C
NO NO
KA3 RL-ML1
S3-P:2-CR:1B
RA3a 24VDC Relay
NO
RL-ML2
NO
ML1-P:2-CR:1E
KTR (1*)
RL-ML1 24VDC Relay
D D
1N4007
ML2-P:2-CR:1E
RL-ML2 24VDC Relay
20
22
34
16
COM
E xxxx-P:xx-CR:xxx E
A3 Valve Bağlantı İsmi Sutun Satır Koordinatı
Valve High Speed Down Direction
Common Valve Valve Connection Name Column Row Coordinate
Sayfa Numarası
Page Number
A A
RX1-P:2-CR:10B
FKR28 RX2-P:2-CR:10B
3A
140-P:2-CR:1B RD1-P:2-CR:10B
F159 RD2-P:2-CR:10B
220V AC
55V AC +
B AC RB1-P:2-CR:10C B
30mA
RB2-P:2-CR:10C
-
10B-P:2-CR:1B GROUND FAULT DC
PROTECTED 35A / 1000V
AUTOMAT FUSE 1000-P:1x-CR:10B
PE-P:1x-CR:10A 1N4007
RU2-P:2-CR:1B
RU2a 24VDC Relay
C 1N4007 C
NO
KA3
S3-P:2-CR:1B
RA3a 24VDC Relay
D D
Valve Test
Button
EB
E /D
EA
HM-SV
V10
E xxxx-P:xx-CR:xxx E
Valve Up Direction High Speed Down Direction Bağlantı İsmi Sutun Satır Koordinatı
A3 Valve Common Valve Valve Valve Connection Name Column Row Coordinate
Sayfa Numarası
Page Number
A A
100-P:1x-CR:10B
1000-P:1x-CR:10B
CANH-P:2-CR:1E
B B
CANL-P:2-CR:1E
MLINT65 Dipswitch Selection Table
ON
100
1000
CANH
CANL
DIPSWITCH 1 2 3 4
X01
X02
X03
X04
X05
X06
X07
X08
X09
X10
X12
X13
X14
X15
X16
X11
4th MLINT65 OFF OFF OFF ON
C C
D D
X01
X03
X11
X13
X02
X05
X07
X08
X09
X12
X15
X04
X06
X10
X14
X16
CALL TERMINALS
xxxx-P:xx-CR:xxx
E E
Bağlantı İsmi Sutun Satır Koordinatı
Connection Name Column Row Coordinate
Sayfa Numarası
Page Number
A A
15cm 4.5cm
15cm 4.5cm
B B
TOP FLOOR
C 15cm 4.5cm C
15cm 4.5cm
D D
FLOOR 2
MLB 4.5cm
E E
4.5cm
F F
FLOOR 1
G G
10cm : RIBBON MAGNET FOR ADVANCED DOOR
OPENNING ZONE
P.S.: IT'S NOT NEEDED TO USE ASM AND YSM WHERE THE ROPE
ML1 YSM
KSR2
KSR1
CAUTION !
I I
ML1,ML2,ASM and YSM Mono-Stable switches must be suitable to
5.11.2.5 article at EN81-20 standard.
A A
15cm
15cm
B B
TOP FLOOR
C 15cm C
15cm
D D
FLOOR 2
MLB
E E
F F
FLOOR 1
G G
ML1
KSR2
KSR1
ML2
FLOOR 0
CAUTION !
I I
ML1 and ML2 Mono-Stable switches must be suitable to
5.11.2.5 article at EN81-20 standard.
A A
15cm 4.5cm
15cm 4.5cm
B B
TOP FLOOR
C 15cm 4.5cm C
15cm 4.5cm
D D
FLOOR 2
MLB 4.5cm
E E
DM
4.5cm
YHM2
F F
FLOOR 1
ML2 ASM
KSR1
JF
M0
FLOOR 0
I
CAUTION ! I
ML1,ML2,ASM and YSM Mono-Stable switches must be
suitable to 5.11.2.5 article at EN81-20 standard.
CAR Title : 2
Magnets M0 Pulse System For Electrical Lifts
With Advenced Door Openning And Re-Levelling
J Project: ML40P_v2 Revision: 1 J
A A
15cm
15cm
B B
TOP FLOOR
C 15cm C
15cm
D D
FLOOR 2
E MLB E
DMY
YHM2
15cm
H H
ML1
ML2
KSR1
KSR2
JFY
JFA
M0
FLOOR 0
I I
CAUTION !
ML1 and ML2 Mono-Stable switches must be suitable to 5.11.2.5
article at EN81-20 standard.
A A
1000-P:1x-CR:10B
ML1-P:2-CR:1E
ML2-P:2-CR:1E
B B
MLKTA
+12V
ML1
ML2
1000
L+
L-
C C
12V 1W (MAX)
AT FLOOR LEVEL LIGHT
+12V
D D
E E
xxxx-P:xx-CR:xxx
100-P:1x-CR:10B
+15V RA +15V
B B
GND GE GND OV
ML40P_v2 LS Inverter ML40P_v2 ADrive Inverter
A RB A OA
-A GE -A OB
B B JP
-B -B
C C
100-P:1x-CR:10B 100-P:1x-CR:10B
D D
+15V +15V
GND GND
ML40P_v2 MEIDEN Inverter ML40P_v2 FUJI Inverter
A PAO A PAO
-A PBO -A PBO
E E
B COM B CM
-B -B
xxxx-P:xx-CR:xxx
Title : Encoder Connections With Inverters
Bağlantı İsmi Sutun Satır Koordinatı
Connection Name Column Row Coordinate
F Sayfa Numarası F
Page Number Project: ML40P_v2 Revision: 1
1000
A A
100
100
MLKLM40_v2 MLKLM40_v2
6A
6A
X01...X09...X16 SC SD X01...X09...X16 SC SD
B B
C C
TOP FLOOR
D D
E E
MIDDLE FLOOR
F F
G G
LANDING OPERATION PANEL
H H
FLOOR 0
xxxx-P:xx-CR:xxx
I Bağlantı İsmi Sutun Satır Koordinatı I
Connection Name Column Row Coordinate
Sayfa Numarası
LANDING OPERATION PANEL Page Number
J 1000 J
X0x Project: ML40P_v2 Revision: 1
Date: 28.5.2019 Sheet: 20a www.mikrolift.com
1 2 3 4 5 6
1 2 3 4 5 6
1000
100
100
A A
6A
X01...X09...X16 SC SD X01...X09...X16 X01...X09...X16 SC SD X01...X09...X16
B B
C C
TOP FLOOR
D D
E E
MIDDLE FLOOR
F F
G G
LANDING OPERATION PANEL
H H
FLOOR 0
xxxx-P:xx-CR:xxx