You are on page 1of 42

INDIAN OIL CORPORATION LIMITED

UTTAR PRADESH STATE OFFICE-I


ESTIMATE
SUB: Rate Contract for Carrying Out Repair & Maintenance Work of Tanks and Pipelines at Operating Locations (Terminals, Depots) under Uttar Pradesh State
Office-I.
Ref. No.: UPSO-I/ENG/ M&I/Rate Contract Date 13.3.2018

Sr. No. Discription of work Unit Qty. Rate Amount


1
PIPELINE WORKS
LAYING & WELDING OF PRODUCT PIPELINE (ABOVE GROUND) IN
ZONE-A
Laying and welding (3 runs min.) above ground/ below ground
pipelines from supplied MS pipes (pipes to be supplied anywhere
within the depot and the contractor shall shift the same to the site
of work at no extra cost with all leads and lifts) of the following
sizes as described below, including cutting bevelling and fixing the
supplied specials such as elbows, bends tees, reducers etc
2 600 mm dia pipe M 1.00 6401.07 6,401.07

3 500 mm dia pipe M 1.00 5334.03 5,334.03

4 450 mm dia pipe M 1.00 4799.34 4,799.34

5 400 mm dia pipe M 1.00 4266.99 4,266.99

6 350 mm dia pipe M 1.00 3733.47 3,733.47

7 300 mm dia Pipe M 1.00 3244.41 3,244.41

8 250 mm dia pipe M 1.00 2712.06 2,712.06

9 200 mm dia pipe M 1.00 2171.52 2,171.52

10 150 mm dia pipe M 1.00 1638.00 1,638.00

11 100 mm dia pipe M 1.00 1097.46 1,097.46

12 80 mm dia pipe M 1.00 830.70 830.70

13 LAYING & WELDING OF PRODUCT PIPELINE (ABOVE GROUND) IN -


ZONE-B
Laying and welding (3 runs min.) above ground/ below ground
pipelines from supplied MS pipes (pipes to be supplied anywhere
within the depot and the contractor shall shift the same to the site
of work at no extra cost with all leads and lifts) of the following
sizes as described below, including cutting bevelling and fixing the
supplied specials such as elbows, bends tees, reducers etc
complete and hydrotesting the pipelines at 10.5 KSC for a
minimum period of 4 Hrs.
The job includes dye penetration (DP) testing of pipeline joints as
per approved QAP.Above ground pipeline to be laid on concrete
pedestals (which is to be constructed as per the respective item of
this schedule)/ piperacks/ TLF shed/ pump house and manifolds
and painting the pipeline as per the specifications enclosed
including the colour coding as per IOC specifications. Welding of
pipeline should conform to Radiography quality. 10% of the joints
shall be radiograped and the cost of the same will be paid
separately as per respective item etc. and as directed at site.
Note:
a. Any repairs to the defective welding shall be made good at no
extra cost. Re radiography of repaired joint shall also be at
contractor's cost.
b. The rates quoted also to include colour coding of pipelines as
per the standards.
Painting Specification: Application for External/ Internal painting
for all product tanks shall be carried out by means of AIRLESS
14 SPRAY
600 mmPAINTING
dia pipe SYSTEM only. M 1.00 6004.98 6,004.98

15 500 mm dia pipe M 1.00 5004.15 5,004.15

16 450 mm dia pipe M 1.00 4503.73 4,503.73

17 400 mm dia pipe M 1.00 4003.32 4,003.32

18 350 mm dia pipe M 1.00 3502.90 3,502.90

19 300 mm dia Pipe M 1.00 3002.49 3,002.49

20 250 mm dia pipe M 1.00 2502.07 2,502.07

21 200 mm dia pipe M 1.00 2001.66 2,001.66

22 150 mm dia pipe M 1.00 1501.24 1,501.24

23 100 mm dia pipe M 1.00 1000.83 1,000.83


ESTIMATE
SUB: Rate Contract for Carrying Out Repair & Maintenance Work of Tanks and Pipelines at Operating Locations (Terminals, Depots) under Uttar Pradesh State
Office-I.
Ref. No.: UPSO-I/ENG/ M&I/Rate Contract Date 13.3.2018

Sr. No. Discription of work Unit Qty. Rate Amount


24 80 mm dia pipe M 1.00 759.25 759.25

25 LAYING & WELDING OF PRODUCT PIPELINE (UNDER GROUND) IN -


ZONE A & ZONE B
Laying and welding (3 runs min.) under ground/ below ground
pipelines from supplied MS pipes (pipes to be supplied anywhere
within the depot and the contractor shall shift the same to the site
of work at no extra cost with all leads and lifts) of the following
sizes as described below, including cutting bevelling and fixing the
supplied specials such as elbows, bends tees, reducers etc
complete and hydrotesting the pipelines at 10.5 KSC for a
minimum period of 4 Hrs.
The job includes dye penetration (DP) testing of pipeline joints as
per approved QAP.Underground pipelines to be laid at a depth as
per site condition/ laying through hume pipes/ culverts & painting
the same as detailed in the enclosed specifications. Welding of
pipeline should be to Radiography quality. 10% of the joints shall
be radiographed and the cost of the same will be paid separately
as per respective item etc. and as directed at site.
Note: a. Any repairs to the defective welding shall be made good
at no extra cost. Re radiography of repaired joint shall also be at
contractor's cost. b. Civil works for laying of UG pipeline laying will
be paid separately. c. Wrapping/Coating to be done as per
specification given below & detailed specification given in tender
document.
i) Sand blast to SA 2.5
ii) Apply a coat of primer (Coal Tar and solvent based primer) of
density 0.90 to 0.95 gms/cm3 and viscosity of 1000-2000
centipoise (Pypkote primer manufacture by IWL or its equivalent)
26 at
600the
mmrate
diaofpipe
100 gms/sq.m. The primer shall be allowed to dry M 1.00 9713.34 9,713.34

27 500 mm dia pipe M 1.00 8091.72 8,091.72

28 450 mm dia pipe M 1.00 7280.91 7,280.91

29 400 mm dia pipe M 1.00 6473.61 6,473.61

30 350 mm dia pipe M 1.00 5663.97 5,663.97

31 300 mm dia Pipe M 1.00 5002.92 5,002.92

32 250 mm dia pipe M 1.00 4193.28 4,193.28

33 200 mm dia pipe M 1.00 3360.24 3,360.24

34 150 mm dia pipe M 1.00 2551.77 2,551.77

35 100 mm dia pipe M 1.00 1718.73 1,718.73

36 80 mm dia pipe M 1.00 1313.91 1,313.91

37 LAYING & WELDING FIRE HYDRANT PIPELINES (ABOVE GROUND) -


IN ZONE-A
Above ground pipeline to be laid on concrete pedestals (which is
to be constructed as per the respective item of this schedule)/ FH
pump house and manifolds and painting the pipeline as per the
specifications enclosed. ( radiography shall not be done for fire
hydrant lines & for lines to be used for water services)
Note:
a. For the sizes of piping below 150 mm, direct stub connection
shall be made on the headers with suitable pad plates and the rate
quoted should include the same.
Painting Scheme : Application for External/ Internal painting for all
product tanks shall be carried out by means of AIRLESS SPRAY
PAINTING SYSTEM only.
1. Surface Preparation as per SA 2½
2. Primer : P1-Inorganic Zinc Ethyl Silicate: Single Coat: DFT-65-75µ
3. Intermediate Coat : U1-Polyamide cured HB Epoxy MIO : Single
Coat: DFT-100-125µ
4. Finish Coat : F1-Two Pack Acrylic Poly-Urethane(PU) : Single
Coat: DFT-40-50µ
Total Min DFT 215µ

38 600 mm dia pipe M 1.00 6176.43 6,176.43

39 500 mm dia pipe M 1.00 5146.83 5,146.83

40 450 mm dia pipe M 1.00 4630.86 4,630.86

41 400 mm dia pipe M 1.00 4117.23 4,117.23


ESTIMATE
SUB: Rate Contract for Carrying Out Repair & Maintenance Work of Tanks and Pipelines at Operating Locations (Terminals, Depots) under Uttar Pradesh State
Office-I.
Ref. No.: UPSO-I/ENG/ M&I/Rate Contract Date 13.3.2018

Sr. No. Discription of work Unit Qty. Rate Amount


42 350 mm dia pipe M 1.00 5579.73 5,579.73

43 300 mm dia Pipe M 1.00 3132.09 3,132.09

44 250 mm dia pipe M 1.00 2618.46 2,618.46

45 200 mm dia pipe M 1.00 2096.64 2,096.64

46 150 mm dia pipe M 1.00 1581.84 1,581.84

47 100 mm dia pipe M 1.00 1060.02 1,060.02

48 80 mm dia pipe M 1.00 802.62 802.62

49 LAYING & WELDING OF FIRE HYDRANT PIPELINES (ABOVE -


GROUND) IN ZONE-B
Laying and welding (3 runs min.) above ground/ below ground
pipelines from supplied MS pipes (pipes to be supplied anywhere
within the depot and the contractor shall shift the same to the site
of work at no extra cost with all leads and lifts) of the following
sizes as described below, including cutting bevelling and fixing the
supplied specials such as elbows, bends tees, reducers etc
complete and hydrotesting the pipelines at 10.5 KSC for a
minimum period of 4 Hrs.
The job includes dye penetration (DP) testing of pipeline joints as
per approved QAP.Above ground pipeline to be laid on concrete
pedestals (which is to be constructed as per the respective item of
this schedule)/ FH pump house and manifolds and painting the
pipeline as per the specifications enclosed. ( radiography shall not
be done for fire hydrant lines & for lines to be used for water
services)
Note:
a. For the sizes of piping below 150 mm, direct stub connection
shall be made on the headers with suitable pad plates and the rate
quoted should include the same.
Painting Scheme : Application for External/ Internal painting for all
product tanks shall be carried out by means of AIRLESS SPRAY
PAINTING SYSTEM only.
1. Surface Preparation as per SA 2½
2. Primer : P3-Red Oxide Zinc Phosphate Primer : Two Coats: DFT-
30-35µ per coat
50 3.
600Finish Coat
mm dia : F2-Aluminium Finish Paint : Two Coats : DFT-15-20µ
pipe M 1.00 5780.34 5,780.34

51 500 mm dia pipe M 1.00 4816.95 4,816.95

52 450 mm dia pipe M 1.00 4335.25 4,335.25

53 400 mm dia pipe M 1.00 3853.56 3,853.56

54 350 mm dia pipe M 1.00 3371.86 3,371.86

55 300 mm dia Pipe M 1.00 2890.17 2,890.17

56 250 mm dia pipe M 1.00 2408.47 2,408.47

57 200 mm dia pipe M 1.00 1926.78 1,926.78

58 150 mm dia pipe M 1.00 1445.08 1,445.08

59 100 mm dia pipe M 1.00 963.39 963.39

60 80 mm dia pipe M 1.00 731.17 731.17


ESTIMATE
SUB: Rate Contract for Carrying Out Repair & Maintenance Work of Tanks and Pipelines at Operating Locations (Terminals, Depots) under Uttar Pradesh State
Office-I.
Ref. No.: UPSO-I/ENG/ M&I/Rate Contract Date 13.3.2018

Sr. No. Discription of work Unit Qty. Rate Amount


61 LAYING & WELDING OF FIRE HYDRANT PIPELINES (UNDER -
GROUND) IN ZONE-A & ZONE-B
Laying and welding (3 runs min.) above ground/ below ground
pipelines from supplied MS pipes (pipes to be supplied anywhere
within the depot and the contractor shall shift the same to the site
of work at no extra cost with all leads and lifts) of the following
sizes as described below, including cutting bevelling and fixing the
supplied specials such as elbows, bends tees, reducers etc
complete and hydrotesting the pipelines at 10.5 KSC for a
minimum period of 4 Hrs.
The job includes dye penetration (DP) testing of pipeline joints as
per approved QAP.
Underground pipelines to be laid at a depth as per site condition/
laying through hume pipes/ culverts & doping the same as
detailed in the enclosed specifications. ( radiography shall not be
done for fire hydrant lines & for lines to be used for water
services). Note: a. Civil works for laying of UG hydrant pipeline will
be paid separately. b. Wrapping/Coating to be done as per
specification given below & detailed specification given in tender
document.
i) Sand blast to SA 2.5
ii) Apply a coat of primer (Coal Tar and solvent based primer) of
density 0.90 to 0.95 gms/cm3 and viscosity of 1000-2000
centipoise (Pypkote primer manufacture by IWL or its equivalent)
at the rate of 100 gms/sq.m. The primer shall be allowed to dry
until the solvent evaporates and the surface becomes tacky.
iii) Pypkote AW 4mm tape is wound around the pipe in spiral
62 fashion
600 mmand bonded completely to the primer coated surface of the
dia pipe M 1.00 9488.70 9,488.70

63 500 mm dia pipe M 1.00 7904.52 7,904.52

64 450 mm dia pipe M 1.00 7112.43 7,112.43

65 400 mm dia pipe M 1.00 6323.85 6,323.85

66 350 mm dia pipe M 1.00 5532.93 5,532.93

67 300 mm dia Pipe M 1.00 4890.60 4,890.60

68 250 mm dia pipe M 1.00 4099.68 4,099.68

69 200 mm dia pipe M 1.00 3285.36 3,285.36

70 150 mm dia pipe M 1.00 2495.61 2,495.61

71 100 mm dia pipe M 1.00 1681.29 1,681.29

72 80 mm dia pipe M 1.00 1285.83 1,285.83

73 Fabrication, edge preparation and laying of supplied pipes above


ground, including leading, laying / placing on pedestals / racks upto
7.2m height from GL / TLF Shed / Pump House / manifolds as per
specifications enclosed, welding (Radiographic quality), hydro-
testing, de-watering and cleaning. Cost of pipeline pedestals and
radiography will be paid separately. Hydrostatic pressure testing
shall be done at 10.5 Kg / sqcm. Rates does not include welding of
flanges. Note: Any repairs to the defective welding shall be made
good at no extra cost. Re radiography of repaired joint shall also be
at contractor's cost.PRODUCT PIPELINE.
The Rates includes the jobs as mentioned above, and the payments
would be made as per nos. of joint basis only. These joints include
no. of weld joints of Bend, Tee, Reducer, Olet etc
a) For the sizes of piping above 50mm dia, Pipe shall be API 5L Gr. B
b) For the sizes of piping 50mm dia and below Pipe shall be ASTM
A106 Gr. B

74 450 mm dia JOINT 1.00 9300.00 9,300.00

75 400 mm dia JOINT 1.00 8266.00 8,266.00

76 350 mm dia JOINT 1.00 7233.00 7,233.00

77 300mm dia. JOINT 1.00 6,200.00 6,200.00

78 250mm dia. JOINT 1.00 5,167.00 5,167.00


ESTIMATE
SUB: Rate Contract for Carrying Out Repair & Maintenance Work of Tanks and Pipelines at Operating Locations (Terminals, Depots) under Uttar Pradesh State
Office-I.
Ref. No.: UPSO-I/ENG/ M&I/Rate Contract Date 13.3.2018

Sr. No. Discription of work Unit Qty. Rate Amount


79 150mm dia. JOINT 1.00 3,100.00 3,100.00

80 100mm dia. JOINT 1.00 2,067.00 2,067.00

81 80mm dia. JOINT 1.00 1,550.00 1,550.00

85 Radiography inspection on product pipe joints of all types and -


thickness including providing all necessary equipment required to
perform the work as per our specification and direction of
engineer-in-charge. The radiographs shall be submitted to the
engineer in charge at site/ third party inspecting agency.
Note: Retaking of radiography due to defective welds/ defective
films/ defective workmanship etc. will be to contractor's cost. For
every failure, radiography has to be done for three additional
joints of same dia. at contractor's cost.

86 600 mm dia pipe EA 1.00 4867.20 4,867.20

87 500 mm dia pipe EA 1.00 4118.40 4,118.40

88 450 mm dia pipe EA 1.00 3744.00 3,744.00

89 400 mm dia pipe EA 1.00 3369.60 3,369.60

90 350 mm dia pipe EA 1.00 2995.20 2,995.20

91 300 mm dia Pipe EA 1.00 2620.80 2,620.80

92 250 mm dia pipe EA 1.00 2246.40 2,246.40

93 200 mm dia pipe EA 1.00 1872.00 1,872.00

94 150 mm dia pipe EA 1.00 1497.60 1,497.60

95 100 mm dia pipe EA 1.00 1123.20 1,123.20

96 80 mm dia pipe EA 1.00 748.80 748.80

97 Provision of Saddle plates for Product & Hydrant Pipelines over -


pedestals including cutting and fabrication of saddle plates from
supplied MS pipes and welding of the same on pipelines under
pedestals with minimum 3 run of welding complete as per
specifications, drawings and directions of Engineer in charge.

98 600 mm dia pipe EA 1.00 9410.25 9,410.25

99 500 mm dia pipe EA 1.00 6534.95 6,534.95

100 450 mm dia pipe EA 1.00 6477.00 6,477.00

101 400 mm dia pipe EA 1.00 6419.11 6,419.11

102 350 mm dia pipe EA 1.00 6360.21 6,360.21

103 300 mm dia Pipe EA 1.00 4779.73 4,779.73

104 250 mm dia pipe EA 1.00 3893.29 3,893.29

105 200 mm dia pipe EA 1.00 3866.78 3,866.78

106 150 mm dia pipe EA 1.00 3226.74 3,226.74

107 100 mm dia pipe EA 1.00 2777.13 2,777.13

108 80 mm dia pipe EA 1.00 2746.70 2,746.70


ESTIMATE
SUB: Rate Contract for Carrying Out Repair & Maintenance Work of Tanks and Pipelines at Operating Locations (Terminals, Depots) under Uttar Pradesh State
Office-I.
Ref. No.: UPSO-I/ENG/ M&I/Rate Contract Date 13.3.2018

Sr. No. Discription of work Unit Qty. Rate Amount


109 RE-PAINTING OF PRODUCT / HYDRANT PIPELINE IN ZONE-A: -
Painting of External surface including color coding of Mild Steel
above ground Pipeline & Fittings such as valves, flanges etc. as per
the attached technical specification and direction of Site engineer.
Item also includes painting of structural surface as per the
following painting scheme:
i. Surface preparation: St-2/St-3
ii. Primer: P4-Self Priming HB Epoxy Primer : One Coat : DFT 100-
125µ
iii. Intermediate Coat: U1-Polyamide cured HB Epoxy mastic
coating : One Coat: DFT 100-125µ
iv. FinishPaint: F1-Two Pack Acrylic Polyerethane (PU) : One Coat:
DFT 40-50µ per coat
v. Total min DFT : 240µ
The items include supply of paints and other required material,
scafolding, labours, tools and tackles etc.

110 600 mm dia pipe M 1.00 754.13 754.13

111 500 mm dia pipe M 1.00 628.44 628.44

112 450 mm dia pipe M 1.00 565.60 565.60

113 400 mm dia pipe M 1.00 502.76 502.76

114 350 mm dia pipe M 1.00 439.91 439.91

115 300 mm dia Pipe M 1.00 377.07 377.07

116 250 mm dia pipe M 1.00 314.22 314.22

117 200 mm dia pipe M 1.00 251.38 251.38

118 150 mm dia pipe M 1.00 188.53 188.53

119 100 mm dia pipe M 1.00 125.69 125.69

120 80 mm dia pipe M 1.00 100.55 100.55

121 RE-PAINTING OF PRODUCT / HYDRANT PIPELINE IN ZONE-B: -


Painting of External surface including color coding of Mild Steel
above ground Pipeline & Fittings such as valves, flanges etc. as per
the attached technical specification and direction of Site engineer.
Surface preparation: St-2/St-3
Primer: P3-Red Oxide Zinc Phosphate Primer : One Coat : DFT 30-
35µ
FinishPaint: F2-Aluminium Finish Paint : Two Coats: DFT 15-20µ per
coat
Total min DFT : 60µ
The items include supply of paints and other required material,
scafolding, labours, tools and tackles etc.

122 600 mm dia pipe M 1.00 556.92 556.92

123 500 mm dia pipe M 1.00 464.10 464.10

124 450 mm dia pipe M 1.00 417.69 417.69

125 400 mm dia pipe M 1.00 371.28 371.28

126 350 mm dia pipe M 1.00 324.87 324.87

127 300 mm dia Pipe M 1.00 278.46 278.46

128 250 mm dia pipe M 1.00 232.05 232.05

129 200 mm dia pipe M 1.00 185.64 185.64

130 150 mm dia pipe M 1.00 139.23 139.23

131 100 mm dia pipe M 1.00 92.82 92.82

132 80 mm dia pipe M 1.00 74.26 74.26

133 Welding of the supplied CS WNRF flanges on the pipelines with 1 -


run inside and two runs outside etc compete and as per
specifications enclosed.
134 600 mm dia EA 1.00 7916.22 7,916.22

135 500 mm dia EA 1.00 6596.46 6,596.46

136 450 mm dia EA 1.00 5937.75 5,937.75


ESTIMATE
SUB: Rate Contract for Carrying Out Repair & Maintenance Work of Tanks and Pipelines at Operating Locations (Terminals, Depots) under Uttar Pradesh State
Office-I.
Ref. No.: UPSO-I/ENG/ M&I/Rate Contract Date 13.3.2018

Sr. No. Discription of work Unit Qty. Rate Amount


137 400 mm dia EA 1.00 5277.87 5,277.87

138 350 mm dia EA 1.00 4617.99 4,617.99

139 300 mm dia EA 1.00 3958.11 3,958.11

140 250 mm dia EA 1.00 3298.23 3,298.23

141 200 mm dia EA 1.00 2639.52 2,639.52

142 150 mm dia EA 1.00 1979.64 1,979.64

143 100 mm dia EA 1.00 1319.76 1,319.76

144 80 mm dia EA 1.00 989.82 989.82

145 25 mm dia EA 1.00 585.00 585.00

146 20 mm dia EA 1.00 468.00 468.00

147 Making flanged joints between flanges (WNRF/SORF/BLRF) -


including supplying and fixing 3 mm thick SW SS gaskets with
graphite fillers, studs, nuts, bolts of approved make for the
following sizes, as per IOCL specifications and site instructions. The
flange joint shall also include providing and fixing multistrand
copper wire/flat for bonding of product pipelines including
provision of lugs.
148 600 mm dia EA 1.00 9126.00 9,126.00

149 500 mm dia EA 1.00 7605.00 7,605.00

150 450 mm dia EA 1.00 6844.50 6,844.50

151 400 mm dia EA 1.00 6084.00 6,084.00

152 350 mm dia EA 1.00 5323.50 5,323.50

153 300 mm dia EA 1.00 4563.00 4,563.00

154 250 mm dia EA 1.00 3802.50 3,802.50

155 200 mm dia EA 1.00 3042.00 3,042.00

156 150 mm dia EA 1.00 2047.50 2,047.50

157 100 mm dia EA 1.00 1500.00 1,500.00

158 80 mm dia EA 1.00 1300.00 1,300.00

159 Making flanged joints between flanges (WNRF/SORF/BLRF) -


including supplying and fixing 3 mm thk PTFE gaskets, studs/ nuts
etc. of approved make for the following sizes as per IOC
specifications and site instructions. The flange joints shall also
include providing and fixing multistrand copper strip/flat for
bonding of product pipelines , Cost of strand/ GI flat shall be paid
separately as per rate in RM.
(for Ethanol)
160 150 mm dia EA 1.00 1590.00 1,590.00

161 100 mm dia EA 1.00 1060.00 1,060.00

162 80 mm dia EA 1.00 848.00 848.00

163 50 mm dia EA 1.00 530.00 530.00

164 25 mm dia EA 1.00 400.00 400.00

165 Fixing & Installation of the supplied ROSOV / DBBV / MOV / GOGV -
/ PLUG VALVE / CS GATE VALVE / QUARTER TURN VALVE / BALL
VALVE of the following sizes on the pipeline including supplying
and fixing 3 mm thk SW SS gaskets, studs/nuts etc of approved
make for the following sizes as per specifications and site
instructions.
Note: The rate quoted for the above items should include:
a. mechanical cleaning/greasing of the valves after erection.
b. supplying and painting the valves/ fittings etc. with two coats of
P3 primer and two coats of F4 finish paint of approved colour and
shade as per colour coding specifications for fittings on product/
fire hydrant lines.
c. Fittings on ethanol service shall be provided with PTFE gaskets
3mm thk.
ESTIMATE
SUB: Rate Contract for Carrying Out Repair & Maintenance Work of Tanks and Pipelines at Operating Locations (Terminals, Depots) under Uttar Pradesh State
Office-I.
Ref. No.: UPSO-I/ENG/ M&I/Rate Contract Date 13.3.2018

Sr. No. Discription of work Unit Qty. Rate Amount


166 600 mm dia EA 1.00 18252.00 18,252.00

167 500 mm dia EA 1.00 15210.00 15,210.00

168 450 mm dia EA 1.00 13689.00 13,689.00

169 400 mm dia EA 1.00 12168.00 12,168.00

170 350 mm dia EA 1.00 10647.00 10,647.00

171 300 mm dia EA 1.00 9126.00 9,126.00

172 250 mm dia EA 1.00 7605.00 7,605.00

173 200 mm dia EA 1.00 6084.00 6,084.00

174 150 mm dia EA 1.00 4095.00 4,095.00

175 100 mm dia EA 1.00 3744.00 3,744.00

176 80 mm dia EA 1.00 3510.00 3,510.00

177 25 mm dia EA 1.00 1755.00 1,755.00

178 Installing the supplied auto recirculation valves as per -


specifications on the product pump headers at the TLF pump house
including supplying, providing and welding flanges of matching
sizes.
Note:
a. The job includes mechanical cleaning of valves and painting of
the valves with 2 coats of P3 primer and 2 coats F4 finish paint of
approved colour and shade as per the directions of site in charge.
The job includes providing and fixing impulse as per
manufacturer's recommendations.
b. Bonding of the valves shall be done using multistrand copper
wire/flat for bonding of product pipelines including provision of
lugs.

179 150 mm dia (suitable for 6000 LPM - MS/ SKO/ HSD TLF pumps) EA 1.00 4212.00 4,212.00

180 100 mm dia (suitable for 2400 - 4800 LPM - MS/ SKO/ HSD TLF EA 1.00 2808.00 2,808.00
pumps)
181 80 mm dia (suitable for 900 - 1800 LPM - MS/ SKO/ HSD TLF pumps) EA 1.00 2106.00 2,106.00

182 Installing the supplied bucket type (100 mesh) strainers as per -
specs and drawing for the product pumps for the following LPM &
pipeline sizes:
Note: The strainers shall be cleaned and painted with 2 coats of P3
primer and 2 coats of F4 finish paint of approved colour and shade
etc as per the directions of the site engineer & the rates quoted
should include the same.

183 300 mm dia (Bucket type) EA 1.00 9360.00 9,360.00

184 250 mm dia (Bucket type) EA 1.00 8190.00 8,190.00

185 200 mm dia (Bucket type) EA 1.00 5850.00 5,850.00

186 150 mm dia (Bucket type) EA 1.00 4095.00 4,095.00

187 100 mm dia (Bucket type) EA 1.00 3276.00 3,276.00

188 Installing the supplied Y type (40 mesh) strainers as per specs and -
drawing for the hydrant / water piping system including fire water
pumps & sprinkler/foam headers for the following LPM & pipeline
sizes:
Note: The strainers shall be cleaned and painted with 2 coats of P3
primer and 2 coats of F4 finish paint of approved colour and shade
etc as per the directions of the site engineer & the rates quoted
should include the same.

189 300 mm (Y type) & flowrate 616KL/HR EA 1.00 9360.00 9,360.00

190 250 mm (Y type) & flowrate 410KL/HR EA 1.00 8190.00 8,190.00

191 150 mm (Y type) & flowrate 2400 LPM EA 1.00 4095.00 4,095.00

192 100 mm (Y type) & flowrate 1500 LPM EA 1.00 3276.00 3,276.00
ESTIMATE
SUB: Rate Contract for Carrying Out Repair & Maintenance Work of Tanks and Pipelines at Operating Locations (Terminals, Depots) under Uttar Pradesh State
Office-I.
Ref. No.: UPSO-I/ENG/ M&I/Rate Contract Date 13.3.2018

Sr. No. Discription of work Unit Qty. Rate Amount


193 Installing the supplied thermal relief valves for the product pipeline EA 1.00 1755.00 1,755.00
and fixing the same on the pump discharge lines to TLF including
painting the valves and connected piping with 2 coats of P3 primer
and 2 coats of F4 finish paint of approved colour and shade as per
the directions of site engineer.
Note:
a. The 20/ 25 mm dia piping connected to the TRVs shall be
measured and paid separatey under respective items.
b. The job also includes providing and fixing 8SWG copper wire for
the flange joints of the assembly.

194 Fabarication & installation of the following sizes of MS pipes -


(ASTM A 106 B, SCH-40) as per specification including cutting,
welding, laying etc as per site requirement including blast cleaning
the surfaces of the pipes to SA 2 1/2 and painting with two coats
of P3 primer and two coats of F2 finish paint as per enclosed
specifications etc complete and as per site directions.
Note: The job includes providing and welding necessary fittings
such as bends/ tees/ flanges etc complete.

195 25mm dia. M 1.00 284.31 284.31

196 20mm dia. M 1.00 232.83 232.83

197 Fixing the supplied Class-150 CS non return valves (swing check / -
lift ) for product and fire hydrant lines as per enclosed specification
& drawings. NRVs shall be mechanically cleaned (St-2) & painted
with 1 coat of P4 primer and 2 coats of F1 finish paint of approved
colour and shade as per specifications and as per directions of site
in charge. Rate is also inclusive of boding with multi-strand Cu
strips.

198 300 mm dia EA 1.00 8424.00 8,424.00

199 250 mm dia EA 1.00 7020.00 7,020.00

200 200 mm dia EA 1.00 5616.00 5,616.00

201 150 mm dia EA 1.00 4095.00 4,095.00

202 100 mm dia EA 1.00 2808.00 2,808.00

203 80 mm dia EA 1.00 2106.00 2,106.00

204 25 mm dia EA 1.00 1755.00 1,755.00

205 25 mm dia Class-800 EA 1.00 1755.00 1,755.00

206 Mounting, installing, aligning, testing and commissioning of the -


power driven product pumpsets supplied by IOC without causing
damage to pumpsets and its accessories. Pumpsets shall be
erected and aligned as per manufacturer's drawings.
Note: The pumpsets shall be supplied anywhere within the
premises and the contractor shall undertake to lead the same to
the foundations at no extra cost. The cost of foundation shall
be measured & paid separately under respective civil items.

207 600 LPM X 30-50 M Head (Submersible Turbine Pump) EA 1.00 29450.00 29,450.00
Note: The pumpsets shall be erected with all accessories on UG tank
manhole plates as per manufacturer's recommendations

208 1200 LPM X 30-50 M Head (Submersible Turbine Pump) EA 1.00 29450.00 29,450.00
Note: The pumpsets shall be erected with all accessories on UG tank
manhole plates as per manufacturer's recommendations

209 6000 LPM X 30-60 M Head (OCF Pump) EA 1.00 22500.00 22,500.00

210 4800 LPM X 30-60 M Head (OCF Pump) EA 1.00 22500.00 22,500.00

211 3600 LPM X 30-60 M Head (OCF Pump) EA 1.00 22500.00 22,500.00

212 2400 LPM X 30-60 M Head (OCF Pump) EA 1.00 22500.00 22,500.00

213 1800 LPM X 30-40 M Head (OCF Pump) EA 1.00 14750.00 14,750.00
ESTIMATE
SUB: Rate Contract for Carrying Out Repair & Maintenance Work of Tanks and Pipelines at Operating Locations (Terminals, Depots) under Uttar Pradesh State
Office-I.
Ref. No.: UPSO-I/ENG/ M&I/Rate Contract Date 13.3.2018

Sr. No. Discription of work Unit Qty. Rate Amount


214 1200 LPM X 20-40 M Head (OCF Pump) EA 1.00 14750.00 14,750.00

215 900 LPM X 20-40 M Head (OCF Pump) EA 1.00 14750.00 14,750.00

216 Installation of the supplied diesel engine driven fire pumpsets EA 1.00 46800.00 46,800.00
mounted on common base frame on foundations including grouting
of supplied foundation bolts without causing damage to the pumps
/ foundation & accessories. The pumpset (fire engines) shall be
installed including supplying and providing AVM pads, grouting the
foundation bolts into the the pockets provided in the foundation
and aligning the pumpset etc. complete as per directions of site in
charge.
Note: a. The job includes transportation of fire engines from any
location inside the Terminal / Installation / Depot premises to the
Fire Water Pumphouse at no extra cost.
b. The item rate quoted should also include cooling water piping
with fittings etc complete.
c. Civil works for foundation will be paid separately
Fire Pumpset Size : 616 Cum/ Hr X 105 M head.

217 Installation of the supplied diesel engine driven fire pumpsets EA 1.00 29250.00 29,250.00
mounted on common base frame on foundations including grouting
of supplied foundation bolts without causing damage to the pumps
/ foundation & accessories. The pumpset (fire engines) shall be
installed including supplying and providing AVM pads, grouting the
foundation bolts into the the pockets provided in the foundation
and aligning the pumpset etc. complete as per directions of site in
charge.
Note: a. The job includes transportation of fire engines from any
location inside the Terminal / Installation / Depot premises to the
Fire Water Pumphouse at no extra cost.
b. The item rate quoted should also include cooling water piping
with fittings etc complete.
c. Civil works for foundation will be paid separately.
Fire Pumpset Size : 410 Cum/ Hr X 88 M head.

218 Installation of supplied fuel tanks on MS structural supports EA 1.00 58500.00 58,500.00
including supplying and providing medium duty MS lines for supply
and return lines to the fire pump from the fuel tank. The MS
structural supports for fuel tank shall be blast cleaned to SA 2 1/2
and painting with two coats of P3 primer and two coats of F4 finish
paint of approved colour & shade as per enclosed specifications and
as per directions of site in charge
Note : The item rate should include MS structural supports for the
above job. Tenderers to note that fuel tanks shall be located such as
to provide for gravity flow for fuel to the fire pumps.

219 Installing the supplied starter/ auto starter assembly of the fire EA 1.00 21060.00 21,060.00
pumps including supplying and erecting the same on ISA 65 x 6
including necessary CC support pillars, blast cleaning of the
structures to SA 2 1/2 and painting the structure with two coats of
P3 primer and F4 finished paint as per enclosed specification and as
per directions of site in charge

220 Supplying and fixing battery stand using ISA 65 x 6 MS angle iron EA 1.00 7020.00 7,020.00
supports with necessary foundation including providing teak wood
plank 20 mm thk for positioning 2x12 V batteries & connecting the
same with starter/auto starter assembly / rechargers etc. complete
Note: The structurals shall be mechanical cleaned and painted with
2 coats of P3 primer and 2 coats of F4 finish paint of approved
colour and shade as per site directions.
ESTIMATE
SUB: Rate Contract for Carrying Out Repair & Maintenance Work of Tanks and Pipelines at Operating Locations (Terminals, Depots) under Uttar Pradesh State
Office-I.
Ref. No.: UPSO-I/ENG/ M&I/Rate Contract Date 13.3.2018

Sr. No. Discription of work Unit Qty. Rate Amount


221 Supplying, fabricating, welding, erecting with suitable supports 150 EA 1.00 35100.00 35,100.00
mm dia medium duty MS ERW tube as per IS 1239 for exhaust line
of fire pumps including installing and erecting the supplied metalic
bellows and silencer; the exhaust pipe shall be adequately
supported in the fire pump house with suitable arrangements; the
entire exhaust pipe shall be lagged using 12 mm dia asbestos rope
and cladding the line in 22 g aluminium sheet with necessary riveting
and fixing;
The exhaust pipe outside the fire pump house shall be taken to a
minimum height of 3 mtrs. above the roof and supported by means
of suitable brackets / guy wires / angle support; The exhaust shall
also be provided with suitable arrangements so as to prevent water
from entering the pipes. The entire work arrangement shall be
completed as per specifications and directions of site in charge.
Note: a. The asbestos rope shall be as per IS supplied by M/s.
Champion/ M/s. Hindustan Composites. B. The
approximate length of 150 mm dia line shall be 15 m per set c. The
exhaust line after the silencer shall be painted with 2 coats of primer
and two coats of heat resistant aluminium paint and the rates
quoted to include the same.

222 Supplying and fixing electric pressure switches of approved make EA 1.00 17550.00 17,550.00
and connecting the same to the delivery headers of the Jockey
pumps and Main hydrant pumps with necessary sockets welded on
the headers, accessories etc complete.

223 Supplying and fixing 150 mm dia pressure gage (0-20 KSC) to the EA 1.00 14040.00 14,040.00
delivery lines of fire pumps, jockey pumps & hydrant network,
including supplying and welding necessary sockets on the pipelines
including 3 way pressure differential valve, etc. complete and as per
directions of site in charge.

224 Interconnection between the starter panels of Fire pumps/ Jockey EA 1.00 140400.00 140,400.00
pumps/ make up water pumps/ pressure switches and Annunciation
panel for auto starting of the fire pumps/ jockey pumps as per the
logic defined in enclosed documents.; Entire interconnections shall
be established using 2 C, 1.1 KV grade armoured copper cable of size
1.5 sqmm;The cable shall be laid at all places including clamping etc
complete as required; The job shall be complete in all respects and
specifications as per the logic and requirements to put the entire
system in AUTO mode as per the specifications.
Note: Tenderers to note that all cabling to be taken underneath
flooring of fire pump house shall be adequately protected by
suitable sized B class GI piping. Also all cables to be laid above
ground shall be neatly dressed and tagged.

225 Installation of supplied CS butterfly valves as per specifications -


enclosed for the monitor/ hydrant points as indicated on drawings
including supplying and providing necessary gaskets/ fasteners etc
complete including cleaning of the butterfly valves and painting
the same in two coats of P3 primer and two coats of F5 finish
paint as per specification of approved colour and shade and as per
direction of Engineer-In-Charge.

226 150 mm dia EA 1.00 3510.00 3,510.00

227 100 mm dia EA 1.00 2808.00 2,808.00

228 80 mm dia EA 1.00 2106.00 2,106.00

229 Fabrication of standard MS stand posts for hydrants from materials EA 1.00 2340.00 2,340.00
supplied by IOCL as per specification etc including painting the post
in two coats of P3 primer and two coats of F4 finish paint etc
complete and as per directions.

230 Fixing the supplied FH line fittings on the Fire hydrant pipelines -
including supplying and fixing 3mm thick gaskets/ nuts/ studs and
all other materials as per enclosed specifications and as directed at
site.
Note: The fittings shall be painted with two coats of F4 finish paint
of approved colour and shade over 2 coats of P3 primer. The rates
quoted should include the same.

231 Double hydrant Points with individual control valves EA 1.00 2808.00 2,808.00
ESTIMATE
SUB: Rate Contract for Carrying Out Repair & Maintenance Work of Tanks and Pipelines at Operating Locations (Terminals, Depots) under Uttar Pradesh State
Office-I.
Ref. No.: UPSO-I/ENG/ M&I/Rate Contract Date 13.3.2018

Sr. No. Discription of work Unit Qty. Rate Amount


232 100 mm Water / Water cum Foam Monitors EA 1.00 4212.00 4,212.00

233 150 mm dia long range water cum foam monitors (500-750 GPM EA 1.00 9360.00 9,360.00
manual HVLR)
234 Installation of IOCL supplied Remote operated High volume Long EA 1.00 29250.00 29,250.00
Range Water Monitors including the following :
(a) Erection of Motors
(b) Fixing of Proximity sensors
(c) Erection of MOV Gate valve
(d) Erection of Remote Control Panel
(e) Fixing of Control & Junction Box
(f) Laying of power cable from Control Panel to HVLR Motors
(g) Laying of Control cable from Remote Control Panel to HVLR
Signal Junction Box
(h) Laying of Signal cable from Remote Control Panel to HVLR Signal
Junction Box
(i) Supply and Fixing of cable tray from Remote Control Panel to
HVLR Junction Box
(j) Glanding & termination of power , control & signal cables
(k) Installation of Gaskets & stud bolts. as directed by IOCL or EIC
(l) Making the stub connection with necessary reinforcement pad
as applicable,
(m) Suppiled foam container for HVLRM including erecting the
same with necessary CC support as per specification and direction of
site incharge.
(n) Installation of suppiled Jet Ratio Control Pump(JRCP) for HVLRM
including erecting the same with necessary CC support as per
specification and direction of site incharge.
Note:
a)The job also include the MS fabricated working platform wherever
required without any extra cost.
235 b) Power supply
Installation distribution
of suppiled forpanel
control MOV's and other
assembly equipments
with necessary are EA 1.00 5850.00 5,850.00
canopy of the HVLRM including supply and erecting the same on ISA
65 x 6 including necessary CC support pillars, painting as per IOCL
specifications and directions of site in charge.

236 Supplying and providing MS structural supports in ISA 65 X 6 for EA 1.00 5850.00 5,850.00
hose boxes supplied by IOC including cutting and welding and
providing necessary CC 1:2:4 support pillars for the structures. The
job also includes blast cleaning of the structures to SA 2 1/2 and
painting with two coats of P3 primer and two coats of F4 finish paint
as per specifications and as per colour and shade as directed by site
in charge.
Note : The stand shall be fixed with hose box at levels as indicated
on drawings.

237 Installing, aligning testing and commissioning of the supplied jockey EA 1.00 29250.00 29,250.00
pump set of capacity 18.5 -100 Cum/hr x 110 m Head for fire
hydrant automation; the job includes grouting foundation bolts in
the pockets of the foundatoion etc complete.
Note:
1.The job also includes connecting the jockey pump to its control
panel by a 3 C, 1.1 KV grade armoured aluminium cable of required
size including necessary glanding/ gland
earthing etc complete. (approximate length of cable not to exceed
25 m). Item rate quoted should include the same.
2. Foundation shall be paid for separately as per the measurement
under respective civil items.

238 Drain Pan arrangement for Product Pump / Fire Water Pump / EA 1.00 11700.00 11,700.00
Jockey Pump
239 Installation, aligning and commissioing of make up water pump / EA 1.00 29250.00 29,250.00
calibration tower pump to be erected on the RCC slab of the UG
water sump on suitable foundation inlcuding foundation bolts/
grouting etc.
Note:
1. The foundation and foundation bolts/ grouting shall be measured
and paid separately under respective civil items. The pumps shall be
connected to the starter to be located on gantry of calibration tower
by a 3 1/2 C, 1.1 KV grade armoured Al. cable (approx. 40 m) of
adequate rating including glanding/ gland earthing at both ends etc
complete
2. Suitable protection in MS angle frame work/ sheet steel for the
pumps shall also be provided. The rates quoted to include the same.
Capacity of Make up Water Pump (90 Cum/ Hr X 36 m head)
ESTIMATE
SUB: Rate Contract for Carrying Out Repair & Maintenance Work of Tanks and Pipelines at Operating Locations (Terminals, Depots) under Uttar Pradesh State
Office-I.
Ref. No.: UPSO-I/ENG/ M&I/Rate Contract Date 13.3.2018

Sr. No. Discription of work Unit Qty. Rate Amount


240 Supply, installation, testing & commissioning of SS-304, 5mm thick EA 1.00 515250.00 515,250.00
of capacity 2000 Ltrs proving measure tank as per weights &
measures manual IS-2391 of 1987 W &M vol 1, Schedule V part XIII
1974.With all necessary parts as per our Drawing. But Manhole
Flange thickness will be 10MM and Top Pipe Cover Pair flange
thickness will be 10MM. Including Polishing. The proving measure
has to be manufactured through an approved vendor of Deptt. of
Legal Metrology, of the State/UT.

241 Supply, installation, testing & commissioning of SS-304, 5mm thick EA 1.00 445450.00 445,450.00
of capacity 1000 Ltrs proving measure tank as per weights &
measures manual IS-2391 of 1987 W &M vol 1, Schedule V part XIII
1974.With all necessary parts as per our Drawing. But Manhole
Flange thickness will be 10MM and Top Pipe Cover Pair flange
thickness will be 10MM. Including Polishing. The proving measure
has to be manufactured through an approved vendor of Deptt. of
Legal Metrology, of the State/UT.

242 Supply, installation, testing & commissioning of SS-304, 5mm thick EA 1.00 265250.00 265,250.00
of capacity 500 Ltrs proving measure tank as per weights &
measures manual IS-2391 of 1987 W &M vol 1, Schedule V part XIII
1974.With all necessary parts as per our Drawing. But Manhole
Flange thickness will be 10MM and Top Pipe Cover Pair flange
thickness will be 10MM. Including Polishing. The proving measure
has to be manufactured through an approved vendor of Deptt. of
Legal Metrology, of the State/UT.

243 Supply, installation, testing & commissioning of SS-304, 5mm thick EA 1.00 215250.00 215,250.00
of capacity 100 Ltrs proving measure tank as per weights &
measures manual IS-2391 of 1987 W &M vol 1, Schedule V part XIII
1974.With all necessary parts as per our Drawing. But Manhole
Flange thickness will be 10MM and Top Pipe Cover Pair flange
thickness will be 10MM. Including Polishing. The proving measure
has to be manufactured through an approved vendor of Deptt. of
Legal Metrology, of the State/UT.

244 Laying and welding (min 3 runs) of AG & UG Pipeline (GI IS-1239 Gr- -
C / MS IS -1239 Gr-C pipes) for pneumatic / service water / DG Set
& Fire Pump Fuel Piping Systems following sizes of pipes at all
places inside the IOCL Location.
Note:
a) Painting of AG & UG piping will be paid separately
b) AG piping shall also be suitably supported on the CC pedestals
as per designed spacing etc., & the same will be paid separately.
c) Excavation & civil works for UG piping will be paid separately.

245 150 mm dia M 1.00 1186.38 1,186.38

246 100 mm dia M 1.00 790.92 790.92

247 80 mm dia M 1.00 593.19 593.19

248 65 mm dia M 1.00 494.33 494.33

249 50 mm dia M 1.00 395.46 395.46

250 25 mm dia M 1.00 197.73 197.73

251 Painting of AG & UG Pipeline (MS IS -1239 Gr-C pipes) for DG Set & -
Fire Pump Fuel Piping Systems at all places inside the IOCL
Location.
a) AG Painting Scheme : Application for External/ Internal painting
for all product tanks shall be carried out by means of AIRLESS
SPRAY PAINTING SYSTEM only.
i. Surface Preparation as per SA 2½
ii Primer : P1-Inorganic Zinc Ethyl Silicate: Single Coat: DFT-65-75µ
iii. Intermediate Coat : U1-Polyamide cured HB Epoxy MIO : Single
Coat: DFT-100-125µ
iv. Finish Coat : F1-Two Pack Acrylic Poly-Urethane(PU) : Single
Coat: DFT-40-50µ
Total Min DFT 215µ
b) UG Painting Specification: Application for External/ Internal
painting for all product tanks shall be carried out by means of
AIRLESS SPRAY PAINTING SYSTEM only.
i. Surface Preparation as per SA 2½
ii. Primer : P1 - Inorganic Zince Ethyl Silicate : Single Coats: DFT-65-
75µ per coat
iii. Finish Coat : F3 - Amine adduct Cured HB Epoxy Liner : Two
Coats : DFT 100-125µ per coat
iv. Total Min DFT 265µ
ESTIMATE
SUB: Rate Contract for Carrying Out Repair & Maintenance Work of Tanks and Pipelines at Operating Locations (Terminals, Depots) under Uttar Pradesh State
Office-I.
Ref. No.: UPSO-I/ENG/ M&I/Rate Contract Date 13.3.2018

Sr. No. Discription of work Unit Qty. Rate Amount


252 150 mm dia M 1.00 395.46 395.46

253 100 mm dia M 1.00 269.10 269.10

254 80 mm dia M 1.00 209.43 209.43

255 65 mm dia M 1.00 171.99 171.99

256 50 mm dia M 1.00 141.57 141.57

257 25 mm dia M 1.00 78.39 78.39

258 Painting of AG & UG Pipeline (GI IS-1239 Gr-C pipes) for pneumatic -
/ service water Systems at all places inside the IOCL Location.
Painting Specification for AG & UG GI piping
i. Surface Preparation as per St-2
ii. Primer : Etch Primer : Single Coat
iii. Primer : P4 - Self Priming HB Epoxy Mastic Coating : One Coat :
DFT 100-125µ
iii. Finish Coat : F1-Two Pack Acrylic Poly-Urethane(PU) : Single
Coat: DFT-40-50µ
iv. Total Min DFT 200µ

259 150 mm dia M 1.00 175.00 175.00

260 100 mm dia M 1.00 154.44 154.44

261 80 mm dia M 1.00 120.51 120.51

262 65 mm dia M 1.00 98.28 98.28

263 50 mm dia M 1.00 81.90 81.90

264 25 mm dia M 1.00 45.63 45.63

265 SUPPLY ITEMS: FOR PIPELINE WORKS -


Supply of MS Pipes
MS PIPE: ASTM SA 106 Gr.B (for pressure relief piping)
266 25mm Dia. ASTM SA 106 Gr.B SCH-80 M 1.00 336.96 336.96

267 20mm Dia. ASTM SA 106 Gr.B SCH-80 M 1.00 284.31 284.31

268 MS PIPE: IS-1239 Gr.C Heavy Duty -


269 150 mm dia M 1.00 1537.38 1,537.38

270 100 mm dia M 1.00 1049.37 1,049.37

271 80 mm dia M 1.00 714.87 714.87

272 65 mm dia M 1.00 575.64 575.64

273 50 mm dia M 1.00 449.28 449.28

274 25 mm dia M 1.00 215.28 215.28

275 GI PIPE: IS-1239 Gr.C Heavy Duty -


276 150 mm dia M 1.00 1537.38 1,537.38

277 100 mm dia M 1.00 1049.37 1,049.37

278 80 mm dia M 1.00 714.87 714.87

279 65 mm dia M 1.00 575.64 575.64

280 50 mm dia M 1.00 449.28 449.28

281 25 mm dia M 1.00 215.28 215.28

282 MS PIPE: API 5L Gr.B -


283 100 mm dia M 1.00 1602.90 1,602.90

284 80 mm dia M 1.00 1125.54 1,125.54

285 Supply of CS butterfly Valve (#150) : Wafer Butterfly Vlv API 609 -
Cat.A CL150 RFTBE Lever Operator DI GGG40 Trim 1 to API 600 602
(13% Cr) EPDM Lining PN 16 API 598 "
286 100 mm dia EA 1.00 8001.63 8,001.63

287 80 mm dia EA 1.00 6170.58 6,170.58


ESTIMATE
SUB: Rate Contract for Carrying Out Repair & Maintenance Work of Tanks and Pipelines at Operating Locations (Terminals, Depots) under Uttar Pradesh State
Office-I.
Ref. No.: UPSO-I/ENG/ M&I/Rate Contract Date 13.3.2018

Sr. No. Discription of work Unit Qty. Rate Amount


288 Supply (Class-150) CS non return valves (swing check / lift ) for -
product and fire hydrant lines as per enclosed specification : Chk
Vlv Dual Plate API 594 A 216 Gr. WCB CL150 RFTBE Wafer Type
between Flanges Trim 1 to API 594 602 (13% Cr) AISI 410 Pin
Inconel X750 Sprng 125 - 250 Ra Finish API 598.

289 250 mm dia EA 1.00 75715.38 75,715.38

290 150 mm dia EA 1.00 34248.24 34,248.24

291 100 mm dia EA 1.00 17124.12 17,124.12

292 80 mm dia EA 1.00 12275.64 12,275.64

293 Pistn Lft Chk Vlv EN ISO 15761 A105 CL800 SWE Bltd Bonnet -
Trim 8 to API 594 602 (13% Cr Hard faced Seat) Horiz. Installation
API 598
294 25 mm dia EA 1.00 7605.00 7,605.00

295 Supply (Class-800) CS Gate Valve for pressure relief lines as per -
enclosed specification
Gate Vlv API 602 CL800 SWE Bltd Bonnet Handwheel Operator
A105 Trim 8 to API 600 602 (13% Cr Hard faced Seat) OS&Y
Graphite Gland Packing API 598 Solid Wedge
296 25 mm dia EA 1.00 6060.60 6,060.60

297 20 mm dia EA 1.00 6060.60 6,060.60

298 Supply (Class-150) CS Gate Valve for pneumatic piping system: -


Gate Vlv MSS SP- 80 CL150 FTE Thd.Bonnet Handwheel Operator
B 62 Cl.C83600 Bronze trim PTFE Gland Packing I.S.R.S. API 598
Solid Wedge

299 50 mm dia EA 1.00 6060.60 6,060.60

300 25 mm dia EA 1.00 6060.60 6,060.60

301 Supply (Class-150) CS Ball Valve for product and fire hydrant lines: -
Ball Vlv LP RB ISO 17292 CL150 RF Two piece Fltg. Ball Lever
Operator A 216 Gr. WCB 13 Cr. Trim RTFE Seat and Seals 125 -
250 Ra Finish Fire safe Per API 607 API 598 Antistatic and
Blowout proof

302 100 mm dia EA 1.00 31391.10 31,391.10

303 80 mm dia EA 1.00 16505.19 16,505.19

304 25 mm dia & (Class- 800) EA 1.00 4298.58 4,298.58

305 Supply of bucket type (100 mesh) strainers as per specs and -
drawing for the product pumps for the following sizes:
306 250 mm dia (Bucket type) & 6000 / 4800 LPM EA 1.00 162000.00 162,000.00

307 200 mm dia (Bucket type) & 3600 / 2400 LPM EA 1.00 143200.00 143,200.00

308 150 mm dia (Bucket type) & 1200 / 900 LPM EA 1.00 121800.00 121,800.00

309 150 mm dia (Bucket type) & 1200 / 900 LPM SS for Ethanol Service EA 1.00 93150.00 93,150.00

310 Supply of Y type (40 mesh) strainers as per specs and drawing for -
the hydrant / water piping system including fire water pumps &
sprinkler/foam headers for the following LPM & pipeline sizes:

311 300 mm (Y type) & flowrate 616KL/HR EA 1.00 70640.00 70,640.00

312 250 mm (Y type) & flowrate 410KL/HR EA 1.00 54635.00 54,635.00

313 150 mm (Y type) & flowrate 2400 LPM EA 1.00 15829.00 15,829.00

314 100 mm (Y type) & flowrate 1500 LPM EA 1.00 7068.00 7,068.00

315 Supply of following Slip On flanges (SORF) conforming to IS-2062 A -


Class 150
316 600 mm dia EA 1.00 14213.16 14,213.16

317 500 mm dia EA 1.00 9934.47 9,934.47

318 450 mm dia EA 1.00 6877.26 6,877.26

319 Supply of following Slip On flanges (Weld neck type- WNRF) -


conforming to ASTM A- 105 Class 150; ANSI B 16.9
320 400 mm dia EA 1.00 18705.96 18,705.96
ESTIMATE
SUB: Rate Contract for Carrying Out Repair & Maintenance Work of Tanks and Pipelines at Operating Locations (Terminals, Depots) under Uttar Pradesh State
Office-I.
Ref. No.: UPSO-I/ENG/ M&I/Rate Contract Date 13.3.2018

Sr. No. Discription of work Unit Qty. Rate Amount


321 350 mm dia EA 1.00 14579.37 14,579.37

322 300 mm dia EA 1.00 9352.98 9,352.98

323 250 mm dia EA 1.00 6327.36 6,327.36

324 200 mm dia EA 1.00 3821.22 3,821.22

325 150 mm dia EA 1.00 2215.98 2,215.98

326 100 mm dia EA 1.00 1414.53 1,414.53

327 80 mm dia EA 1.00 1146.60 1,146.60

328 65 mm dia EA 1.00 588.51 588.51

329 50 mm dia EA 1.00 482.04 482.04

330 Supply of following BLRF flanges conforming to IS 2062 A Class-150 -

331 600 mm dia EA 1.00 24146.46 24,146.46

332 500 mm dia EA 1.00 16429.14 16,429.14

333 450 mm dia EA 1.00 13449.15 13,449.15

334 Supply of following BLRF flanges conforming to ASTM A- 105 Class -


150; ANSI B 16.5
335 400 mm dia EA 1.00 9475.83 9,475.83

336 350 mm dia EA 1.00 6571.89 6,571.89

337 300 mm dia EA 1.00 5807.88 5,807.88

338 250 mm dia EA 1.00 4279.86 4,279.86

339 200 mm dia EA 1.00 3209.31 3,209.31

340 150 mm dia EA 1.00 1925.82 1,925.82

341 100 mm dia EA 1.00 1182.87 1,182.87

342 80 mm dia EA 1.00 852.93 852.93

343 65 mm dia EA 1.00 650.52 650.52

344 50 mm dia EA 1.00 375.57 375.57

345 Supply of Auto Recirculation valves as per specifications -


346 150 mm dia (suitable for 6000 LPM - MS/ SKO/ HSD TLF pumps) EA 1.00 99000.00 99,000.00

347 Supply of Thermal Relief Valves as per specifications Inlet 20 mm X EA 1.00 13413.00 13,413.00
Outlet 25 mm
348 PIPE FITTINGS : Supplying the following sizes of Elbows/ Tees/ -
Reducer made of carbon steel seamless pipes with bevelled ends
as per enclosed specifications for the following sizes Note: The
fittings shall be as per ASTM A 234 Grade WPB schedule 40 and
dimensions as per ASME B 16.5.
Note: The quantities given are only indicative.The actual quantities
to be supplied will be based on the finalised drawing for pipeline
routing.
90 Deg LR elbow (1.5D)

349 600 mm dia EA 1.00 37977.03 37,977.03

350 500 mm dia EA 1.00 24451.83 24,451.83

351 450 mm dia EA 1.00 20631.78 20,631.78

352 400 mm dia EA 1.00 15817.23 15,817.23

353 350 mm dia EA 1.00 11691.81 11,691.81

354 300 mm dia EA 1.00 7840.17 7,840.17

355 250 mm dia EA 1.00 5639.40 5,639.40

356 200 mm dia EA 1.00 3438.63 3,438.63

357 150 mm dia EA 1.00 1605.24 1,605.24

358 100 mm dia EA 1.00 650.52 650.52


ESTIMATE
SUB: Rate Contract for Carrying Out Repair & Maintenance Work of Tanks and Pipelines at Operating Locations (Terminals, Depots) under Uttar Pradesh State
Office-I.
Ref. No.: UPSO-I/ENG/ M&I/Rate Contract Date 13.3.2018

Sr. No. Discription of work Unit Qty. Rate Amount


359 80 mm dia EA 1.00 451.62 451.62

360 65 mm dia EA 1.00 313.56 313.56

361 50 mm dia EA 1.00 168.48 168.48

362 25 mm dia EA 1.00 84.24 84.24

363 PIPE FITTINGS : Supplying the following sizes of Elbows/ Tees/ -


Reducer made of carbon steel seamless pipes with bevelled ends
as per enclosed specifications for the following sizes Note: The
fittings shall be as per ASTM A 234 Grade WPB schedule 40 and
dimensions as per ASME B 16.5.
Note: The quantities given are only indicative.The actual quantities
to be supplied will be based on the finalised drawing for pipeline
routing.
45 Deg LR elbow (1.5D)

364 600 mm dia EA 1.00 22923.81 22,923.81

365 500 mm dia EA 1.00 20783.88 20,783.88

366 450 mm dia EA 1.00 11462.49 11,462.49

367 400 mm dia EA 1.00 8558.55 8,558.55

368 350 mm dia EA 1.00 7030.53 7,030.53

369 300 mm dia EA 1.00 5195.97 5,195.97

370 250 mm dia EA 1.00 3515.85 3,515.85

371 200 mm dia EA 1.00 2139.93 2,139.93

372 150 mm dia EA 1.00 1200.42 1,200.42

373 100 mm dia EA 1.00 466.83 466.83

374 80 mm dia EA 1.00 276.12 276.12

375 65 mm dia EA 1.00 161.46 161.46

376 50 mm dia EA 1.00 107.64 107.64

377 25 mm dia EA 1.00 53.82 53.82

378 PIPE FITTINGS : Supplying the following sizes of Elbows/ Tees/ -


Reducer made of carbon steel seamless pipes with bevelled ends
as per enclosed specifications for the following sizes Note: The
fittings shall be as per ASTM A 234 Grade WPB schedule 40 and
dimensions as per ASME B 16.5.
Note: The quantities given are only indicative.The actual quantities
to be supplied will be based on the finalised drawing for pipeline
routing.
Equal Tee

379 600 mm dia EA 1.00 49667.67 49,667.67

380 500 mm dia EA 1.00 38206.35 38,206.35

381 450 mm dia EA 1.00 24375.78 24,375.78

382 400 mm dia EA 1.00 18338.58 18,338.58

383 350 mm dia EA 1.00 14671.80 14,671.80

384 300 mm dia EA 1.00 9934.47 9,934.47

385 250 mm dia EA 1.00 6877.26 6,877.26

386 200 mm dia EA 1.00 3989.70 3,989.70

387 150 mm dia EA 1.00 2101.32 2,101.32

388 100 mm dia EA 1.00 1100.97 1,100.97

389 80 mm dia EA 1.00 771.03 771.03


ESTIMATE
SUB: Rate Contract for Carrying Out Repair & Maintenance Work of Tanks and Pipelines at Operating Locations (Terminals, Depots) under Uttar Pradesh State
Office-I.
Ref. No.: UPSO-I/ENG/ M&I/Rate Contract Date 13.3.2018

Sr. No. Discription of work Unit Qty. Rate Amount


390 PIPE FITTINGS : Supplying the following sizes of Elbows/ Tees/ -
Reducer made of carbon steel seamless pipes with bevelled ends
as per enclosed specifications for the following sizes Note: The
fittings shall be as per ASTM A 234 Grade WPB schedule 40 and
dimensions as per ASME B 16.5.
Note: The quantities given are only indicative.The actual quantities
to be supplied will be based on the finalised drawing for pipeline
routing.
Un Equal Tee

391 600 x 600 x 500 mm EA 1.00 49667.67 49,667.67

392 600 x 600 x 450 mm EA 1.00 49667.67 49,667.67

393 600 x 600 x 400 mm EA 1.00 49667.67 49,667.67

394 600 x 600 x 350 mm EA 1.00 49667.67 49,667.67

395 600 x 600 x 300 mm EA 1.00 49667.67 49,667.67

396 600 x 600 x 150 mm EA 1.00 49667.67 49,667.67

397 600 x 600 x 100 mm EA 1.00 49667.67 49,667.67

398 500 x 500 x 450 mm EA 1.00 38206.35 38,206.35

399 500 x 500 x 400 mm EA 1.00 38206.35 38,206.35

400 500 x 500 x 350 mm EA 1.00 38206.35 38,206.35

401 500 x 500 x 300 mm EA 1.00 38206.35 38,206.35

402 500 x 500 x 150 mm EA 1.00 38206.35 38,206.35

403 500 x 500 x 100 mm EA 1.00 38206.35 38,206.35

404 400 x 400 x 350 mm EA 1.00 18338.58 18,338.58

405 400 x 400 x 300 mm EA 1.00 18338.58 18,338.58

406 400 x 400 x 250 mm EA 1.00 18338.58 18,338.58

407 400 x 400 x 200 mm EA 1.00 18338.58 18,338.58

408 400 x 400 x 150 mm EA 1.00 18338.58 18,338.58

409 400 x 400 x 100 mm EA 1.00 18338.58 18,338.58

410 350 x 350 x 300 mm EA 1.00 15282.54 15,282.54

411 350 x 350 x 250 mm EA 1.00 15282.54 15,282.54

412 350 x 350 x 200 mm EA 1.00 15282.54 15,282.54

413 350 x 350 x 150 mm EA 1.00 15282.54 15,282.54

414 350 x 350 x 100 mm EA 1.00 15282.54 15,282.54

415 300 x 300 x 250 mm EA 1.00 9934.47 9,934.47

416 300 x 300 x 200 mm EA 1.00 9934.47 9,934.47

417 300 x 300 x 150 mm EA 1.00 9934.47 9,934.47

418 300 x 300 x 100 mm EA 1.00 9934.47 9,934.47

419 250 x 250 x 200 mm EA 1.00 6954.48 6,954.48

420 250 x 250 x 150 mm EA 1.00 6954.48 6,954.48

421 250 x 250 x 100 mm EA 1.00 6954.48 6,954.48

422 250 x 250 x 80 mm EA 1.00 6954.48 6,954.48

423 200 x 200 x 150 mm EA 1.00 3989.70 3,989.70

424 200 x 200 x 100 mm EA 1.00 3989.70 3,989.70

425 200 x 200 x 80 mm EA 1.00 3989.70 3,989.70

426 150 x 150 x 100 mm EA 1.00 2101.32 2,101.32


ESTIMATE
SUB: Rate Contract for Carrying Out Repair & Maintenance Work of Tanks and Pipelines at Operating Locations (Terminals, Depots) under Uttar Pradesh State
Office-I.
Ref. No.: UPSO-I/ENG/ M&I/Rate Contract Date 13.3.2018

Sr. No. Discription of work Unit Qty. Rate Amount


427 150 x 150 x 80 mm EA 1.00 2101.32 2,101.32

428 100 x 100 x 80 mm EA 1.00 1780.43 1,780.43

429 PIPE FITTINGS : Supplying the following sizes of Elbows/ Tees/ -


Reducer made of carbon steel seamless pipes with bevelled ends
as per enclosed specifications for the following sizes Note: The
fittings shall be as per ASTM A 234 Grade WPB schedule 40 and
dimensions as per ASME B 16.5.
Note: The quantities given are only indicative.The actual quantities
to be supplied will be based on the finalised drawing for pipeline
routing.
Reducers (Concentric)

430 300 X 250 mm EA 1.00 3515.85 3,515.85

431 300 X 200 mm EA 1.00 3515.85 3,515.85

432 250 X 150 mm EA 1.00 1681.29 1,681.29

433 150 X 100 mm EA 1.00 841.23 841.23

434 150 X 80 mm EA 1.00 841.23 841.23

435 100 X 80 mm EA 1.00 359.19 359.19

436 PIPE FITTINGS : Supplying the following sizes of Elbows/ Tees/ -


Reducer made of carbon steel seamless pipes with bevelled ends
as per enclosed specifications for the following sizes Note: The
fittings shall be as per ASTM A 234 Grade WPB schedule 40 and
dimensions as per ASME B 16.5.
Note: The quantities given are only indicative.The actual quantities
to be supplied will be based on the finalised drawing for pipeline
routing.
Reducers (Eccentric)

437 350 X 250 mm EA 1.00 8405.28 8,405.28

438 250 X 200 mm EA 1.00 3246.75 3,246.75

439 250 X 150 mm EA 1.00 3246.75 3,246.75

440 150 X 100 mm EA 1.00 955.89 955.89

441 150 X 100 mm EA 1.00 955.89 955.89

442 100 X 80 mm EA 1.00 458.64 458.64

443 Supplying 3 Ph, 440 V NFLP type mono block motor pumpset with EA 1.00 248917.50 248,917.50
base frame & required accessories including heavy duty GM foot
valve for the suction side of the pump etc as per specifications.
Makeup Water Pump : Capacity of pump: 90 Cum/ Hr X 36 M head.

444 Supply, handling, erection, testing & commissioning of Cast -


Carbon Steel ASTM - A 216, Gr. WCB Double Flanged Gate Valve as
per BS : 1414 ; API-600 , Class # 150, with stainless steel rising
spindle & internal working parts,flange drilled as per ANSI B 16.5
Cl # 150,raised face and hand wheel including making flanged
joints at both ends with SW SS gaskets, supply & fixing of nuts,
bolts, etc., all complete in all respect as per the direction of
engineer-in- charge.

445 250 mm dia EA 1.00 53315.00 53,315.00

446 200 mm dia EA 1.00 35821.00 35,821.00

447 150 mm dia EA 1.00 22215.00 22,215.00

448 100 mm dia EA 1.00 13051.00 13,051.00

449 80 mm dia EA 1.00 9385.00 9,385.00

450 65 mm dia EA 1.00 6635.00 6,635.00

451 Sprinkler Nozzles EA 1.00 343.00 343.00


Supply, handling, erection, testing & commissioning of Medium
Velocity Water Spray Nozzle of all types in 1/2" BSPT male thread
including all necessary consumables complete in all respect as per
the direction of engineer-in- charge. Nozzles to be replaced exactly
as per existing type of nozzle installed.
ESTIMATE
SUB: Rate Contract for Carrying Out Repair & Maintenance Work of Tanks and Pipelines at Operating Locations (Terminals, Depots) under Uttar Pradesh State
Office-I.
Ref. No.: UPSO-I/ENG/ M&I/Rate Contract Date 13.3.2018

Sr. No. Discription of work Unit Qty. Rate Amount


452 Installation of IOC supplied Spray Nozzles: Handling,erection,testing EA 1.00 149.00 149.00
& commissioning of Medium Velocity Water Spray Nozzle of 1/2"
BSPT male thread including all necessary consumables complete in
all respect as per the direction of engineer-in- charge.

453 Supply,handling,erection,testing & commissioning of Foam -


Chanber / Maker with Vapour Seal suitable for Cone Roof Tank of
following capacity and inlet & outlet sizes including supply &
erection of companion SORF flanges of ANSI B 16.5 Cl# 150,G.I nuts
& bolts,gaskets etc complete in all respect.The job also includes
providing all necessary scaffolding/support structure for carrying
out the erection job at different heights at free of cost.

454 Capacity - 230.00 lpm ; Size : 65NB/100NB EA 1.00 8620.00 8,620.00

455 Capacity - 664.00 lpm ; Size : 80NB/150NB EA 1.00 18919.00 18,919.00

456 Capacity - 945.50 lpm ; Size : 100NB/200NB EA 1.00 22065.00 22,065.00

457 Supply,handling,erection,testing & commissioning of Foam Pourer -


suitable for Cone Roof Tank of following inlet sizes including supply
& erection of companion SORF flanges of ANSI B 16.5 Cl# 150,G.I
nuts & bolts,gaskets etc complete in all respect.The job also
includes providing all necessary scaffolding/support structure for
carrying out the erection job at different heights at free of cost

458 200 NB EA 1.00 11042.00 11,042.00

459 150 NB EA 1.00 9185.00 9,185.00

460 100 NB EA 1.00 7896.00 7,896.00

461 Supply,handling,cutting,edge preparation, fabrication, welding, -


erection (under or above ground), supporting, testing &
commissioning of S.S. Pipe IS:316 marked, schedule-40, including
supply & welding of all necessary S.S. fittings such as
elbow,reducer, tee, nipple , socket etc. and S.S. Flanges with
S.S.nuts & bolts,gaskets & washers,U-bolts etc to complete the
work in all respect as per the direction of engineer-in- charge.

462 50 NB M 1.00 2501.00 2,501.00

463 32 NB M 1.00 1553.00 1,553.00

464 25 NB M 1.00 1149.00 1,149.00

465 Supply,handling,erection,testing & commissioning of Female -


Screwed (BSPT) lever operated Stainless Steel Ball Valve suitable
for handling corrosive liquid.The valve should have S.S.body-ASTM
A 351 CF 8M,Ball & stem AISI 316,seat test pressure
10kg/sq.cm.The job includes the supply & fittings of all necessary
S.S. fittings required to complete the job in all respect as per the
direction of engineer-in- charge.

466 50 NB EA 1.00 13623.00 13,623.00

467 32 NB EA 1.00 10762.00 10,762.00

468 25 NB EA 1.00 5336.00 5,336.00

469 Supply,handling,erection,testing & commissioning of Stainless -


Steel Female Screwed (BSPT) horizontal type Non-Return
Valve/Check Valve with all S.S.internals ,seat test pressure
10kg/sq.cm.The job includes the supply & fittings of all necessary
S.S. fittings required to complete the job in all respect as per the
direction of engineer-in- charge.
470 32 NB EA 1.00 10762.00 10,762.00

471 25 NB EA 1.00 5336.00 5,336.00


ESTIMATE
SUB: Rate Contract for Carrying Out Repair & Maintenance Work of Tanks and Pipelines at Operating Locations (Terminals, Depots) under Uttar Pradesh State
Office-I.
Ref. No.: UPSO-I/ENG/ M&I/Rate Contract Date 13.3.2018

Sr. No. Discription of work Unit Qty. Rate Amount


472 S/Fab of Galvanised MS Pipe: Supply, handling, cutting, edge -
preparation, fabrication, erection of above ground Screwed type
G.I. Pipeline for Sprinkler and foam system at select vertical
storage tanks at any height, including testing & commissioning.
The pipe to be used shall be of Mild steel Galvanised as per IS
:1239 ; Part-I (Annexure XI). Class / pressure rating - Heavy grade
for dia 150 mm and below and minimum 6.34 mm for pipes 200
and above (pipes as per IS 3589, Grade 410). Galvanising minimum
360 gm/sq.m. as per IS 4736 (Annexure XII). Rates include supply &
fitting of all necessary G.I.Heavy grade fittings such as different
types of threaded Tees, threaded reducer, threaded elbows,
threaded cross etc . conforming to IS:1239,Part-II and SORF
threaded GI Flanges ANSI B 16.5 Cl# 150 with GI nuts,bolts,
gaskets & GI washers, teflon,jute. hold-tight etc all
consumeables, U-bolts etc to complete the work in all respect.
Sprinkler rings to have flanged joints with one flange to flange
segment made of approx 12 to 18m length. The sockets for spray
nozzle shall also be GI and welded on the sprinkler ring pipes.
Entire T shall be dip galvanised before installing. Riser pipes to
have a drain at the bottom most portions with valve. Riser &
bottom pipes to also have flanges at suitable places for
maintenance purpose, (minimum 4 per riser) rates of which are
inclusive in the rates Note 1: Galvanising on Pipes ,fittings and
flanges shall be in accordance with IS 4736 latest edition. This job
is to be carried in running tank which is full of flammable
petroleum products. So highest level of safety precaution to be
taken as per direction of Site-In-Charge / Terminal In-Charge by
473 contractor
200 mm diaduring execution of job. The GI pipes to be joined by M 1.00 4177.34 4,177.34

474 150 mm dia M 1.00 3133.00 3,133.00

475 100 mm dia M 1.00 2012.00 2,012.00

476 80 mm dia M 1.00 1531.00 1,531.00

477 65 mm dia M 1.00 1237.00 1,237.00

478 50 mm dia M 1.00 1006.00 1,006.00

479 Supply and providing new GI pipe for sprinkler ring after removing -
existing corroded section by hack saw cutting/unbolting flanges
etc
480 200 mm dia M 1.00 4028.00 4,028.00

481 150 mm dia M 1.00 3021.00 3,021.00

482 100 mm dia M 1.00 2014.00 2,014.00

483 80 mm dia M 1.00 1526.00 1,526.00

484 65 mm dia M 1.00 1240.00 1,240.00

485 50 mm dia M 1.00 954.00 954.00

486 Supply & installation of MS Galvanised "U" clamp of size including EA 1.00 187.00 187.00
providing M16 U-bolts with nuts suitable for 150 mm pipeline

487 Supply & installation of MS Galvanised "U" clamp of size including EA 1.00 146.00 146.00
providing M16 U-bolts with nuts suitable for 65 mm pipeline

488 Dismantling & stacking of CI/GI/MS/SS pipe (of any specification) -


anywhere inside of IOC location
489 600 mm dia pipe M 1.00 1755.00 1,755.00

490 500 mm dia pipe M 1.00 1170.00 1,170.00

491 450 mm dia pipe M 1.00 1053.00 1,053.00

492 400 mm dia pipe M 1.00 936.00 936.00

493 350 mm dia pipe M 1.00 819.00 819.00

494 300 mm dia Pipe M 1.00 702.00 702.00

495 250 mm dia pipe M 1.00 585.00 585.00

496 200 mm dia pipe M 1.00 468.00 468.00

497 150 mm dia pipe M 1.00 351.00 351.00

498 100 mm dia pipe M 1.00 234.00 234.00


ESTIMATE
SUB: Rate Contract for Carrying Out Repair & Maintenance Work of Tanks and Pipelines at Operating Locations (Terminals, Depots) under Uttar Pradesh State
Office-I.
Ref. No.: UPSO-I/ENG/ M&I/Rate Contract Date 13.3.2018

Sr. No. Discription of work Unit Qty. Rate Amount


499 80 mm dia pipe M 1.00 175.50 175.50

500 Dismantling of ROSOV / DBBV / MOV / GOGV / PLUG VALVE / CS -


GATE VALVE / QUARTER TURN VALVE / BALL VALVE/ Butterfly
valves of the following sizes on the pipeline including stacking the
same inside premises.
501 600 mm dia EA 1.00 4680.00 4,680.00

502 500 mm dia EA 1.00 3510.00 3,510.00

503 450 mm dia EA 1.00 2925.00 2,925.00

504 400 mm dia EA 1.00 2340.00 2,340.00

505 350 mm dia EA 1.00 1872.00 1,872.00

506 300 mm dia EA 1.00 1755.00 1,755.00

507 250 mm dia EA 1.00 1404.00 1,404.00

508 200 mm dia EA 1.00 1170.00 1,170.00

509 150 mm dia EA 1.00 936.00 936.00

510 100 mm dia EA 1.00 702.00 702.00

511 80 mm dia EA 1.00 585.00 585.00

512 Structural Steel Works: KG 1.00 102.00 102.00


Supplying, transporting, fabricating, erecting Structural steel work
from rolled sections and built-up sections like flats, tees, angles,
channels, plates, pipes etc for various structural elements as
required in POL Terminal/Depot other than in Vertical oil storage
tank.
Preparation of drawing, design & specification shall be arranged by
contractor at his own cost as per guidance of IOCL.
Item also includes painting of structural surface as per the following
painting scheme:
i. Surface preparation: St-2/St-3
ii. Primer: P4-Self Priming HB Epoxy Primer : One Coat : DFT 100-
125µ
iii. Intermediate Coat: U1-Polyamide cured HB Epoxy mastic coating :
One Coat: DFT 100-125µ
iv. FinishPaint: F1-Two Pack Acrylic Polyerethane (PU) : One Coat:
DFT 40-50µ per coat
v. Total min DFT : 240µ
The items include supply of paints and other required meterial,
scafolding, labours, tools and tackles etc.
The make of Structural Steel / tubular steel shall be of
SAIL/Tata/RINL/Jindal. In case some small Mild Steel sections are
not manufactured by SAIL/Tata, steel of other manufactuer may be
used which must confirm the relevant IS code with prior approval of
Engineer-In-Charge."

513 STRUCTURAL STEEL GRATING: KG 1.00 101.00 101.00


Supplying, transporting, fabricating in factory, Electroforged
rectangular gratings as per layout drawings with plain bearing bar
and Cross Bars duly press locked into bearing bar by electrofusion.
Gratings shall be duly hot dip galvanized after fabrication given in
the detailed specification with minimum thickness of galvanising of
average 85 microns all through the sectional area, & erecting in
position and fixing in position mild steel Grating welded/
bolted/placed with adequate clamps wherevever applicable in
floors, platforms, staircase steps, trench covers, landings etc.
including cutting for openings wherever required as specified and
directed at all floors at all levels etc. complete. The grating shall
confirm to the typical section details of grating as shown in drawing .
This works includes setting in position in Footpath/
Gutter/Drains/Floors to the required level and line over a bed of
20mm Average thick cement mortar (1:3). NOTE: The Grating shall
be factory made, i.e. fabricated & Hot dip Gavanised in shop &
transported to site for erection.

514 TANK FABRICATION WORKS -


515 Providing foundations for the anchor chairs as per drg. J- 153/ 15 EA 1.00 10000.00 10,000.00
including excavation in sand pad, supplying and providing tor steel
reinforcements, shoring, shuttering, laying concrete in CC 1: 1 1/2: 3
including supplying & providing 20 mm dia HD bolt etc complete and
as per directions of Engineer-in-charge. No. of anchor chairs as per
B&R drawing BR/CR/220.
RATE PER ANCHOR CHAIR
ESTIMATE
SUB: Rate Contract for Carrying Out Repair & Maintenance Work of Tanks and Pipelines at Operating Locations (Terminals, Depots) under Uttar Pradesh State
Office-I.
Ref. No.: UPSO-I/ENG/ M&I/Rate Contract Date 13.3.2018

Sr. No. Discription of work Unit Qty. Rate Amount


516 FABRICATION, ERECTION & WELDING OF MS PLATES FOR REPAIR OF KG 1.00 26.00 26.00
EXISTING CR/IFR/EFR VERTICAL TANKS FOR PRODUCT/WATER
STORAGE:
Item includes replacement of bottom, annular, shell & roof plates in
existing tank. It also includes replacement of shell manhole
reinforcement plate & wind girder plates. All other items such as
labour, equipment, power, consumables etc shall be supplied by
contractor. While replacing roof plates of existing tanks, special care
should be taken to avoid local sagging/depression in the roof plates.
Note :
a) The steel plates shall be of Mild Steel Plate conforming to IS 2062
GR.'B'/IS 2062 E250B fully killed & will be free issue material for this
item.
b) Item does not include dismantling of damaged plate in existing
tanks.
c) Rate to include making all arrangment for proper installation of
new plates after dismantling of damaged plates.
d) The rate shall be inclusive of provision of metalic tubular
scaffolding up to required height as per site condition.
e) Item does not include any painting works of steel plates.
f) Radiography will be paid separately.

517 Structural Steel Works in Vertical Tanks: KG 1.00 137.12 137.12


Supplying, transporting, fabricating, erecting Structural steel work
from rolled sections and built-up sections like flats, tees, angles,
channels, plates, pipes etc for various structural elements as
required at the Vertical oil storage tank. Preparation of drawing,
design & specification shall be arranged by contractor at his own
cost as per guidance of IOCL. Item also includes applying Primer
P4{with one coat of two pack high build modified alumunium epoxy
mastic coating possessing self priming properties and good adhesion
to even @ 175 microns DFT/coat} and two coats of Finish Paint F1
{Two pack aliphatic acrylic polyurethane finish paint @ (40-45)
microns DFT/coat after preparing surface by Hand cleaning wire
brush all complete as per drawing, specification and direction of Site-
In-Charge.

The make of Structural Steel / tubular steel shall be of


SAIL/Tata/RINL/Jindal. In case some small Mild Steel sections are
not manufactured by SAIL/Tata, steel of other manufactuer may be
used which must confirm the relevant IS code with prior approval of
Engineer-In-Charge."

518 CALIBRATION OF TANKS: EA 1.00 50000.00 50,000.00


Item includes bottom calibration with actual physical measurement
by water meter till datum plate & calibration of tank shell by
strapping periphery of different strakes above and below the
horizontal weld joints OR by "Optical Reference & Line
Methodology" method.
In case, the calibration is done by strapping method, double stage
scaffolding with MS structures / pipes is also included in this item.
Item includes cost towards statutory payment to be made to the
authorities and all other incidental costs.
Item includes preparation & submission of calibration charts in
quadruplicate duly approved by the tank calibration authority.
Water required for the calibration till datum plate shall be provided
by IOCL within terminal premises or paid for separately as per water
supply item rate in this contract.
Handling of water for calibration till datum plate level including
provision of water conveying pipes, water pumps, all material and
labour, as required shall be arranged by the contractor & is inclusive
in the rate. It is also inclusive of all neccessary arrangements to
pump the water into tank & to drain out the water also at no extra
cost to IOCL.
This rate is universally applicable for all tank sizes & capacities.
ESTIMATE
SUB: Rate Contract for Carrying Out Repair & Maintenance Work of Tanks and Pipelines at Operating Locations (Terminals, Depots) under Uttar Pradesh State
Office-I.
Ref. No.: UPSO-I/ENG/ M&I/Rate Contract Date 13.3.2018

Sr. No. Discription of work Unit Qty. Rate Amount


519 HYDRO-TESTING OF TANKS: EA 1.00 50000.00 50,000.00
Cleaning of tank after hydrotest, boxing up of tank after completion
of all works & inspection, including supplying and fixing gasket along
with bolts & nuts confirming to IS 1363 & 1367 and washers of
approved quality . Job includes all Man holes , Nozzles,Inlet /outlet
valves, water draw off valves etc. complete & as per instruction at
site.
Water required for the hydro-testing of tank shall be provided by
IOCL within terminal premises or paid for separately as per water
supply item in this contract.
Water conveying pipes, water pumps, all material and labour, as
required shall be arranged by the contractor Including providing
rubber gasket for hydrotesting. However the vendor shall make all
neccessary arrangemens to pump the water into tank & to drain out
the water also at no extra cost to IOCL.
This rate is universally applicable for all tank sizes & capacities.

520 PREPARATION OF TANK FABRICATION DRAWINGS: JOB 1.00 50000.00 50,000.00


Submission of detailed design/ fabrication drawings for the differnt
size of tanks for approval of IOCL. Item includes submission of as
built drawings (4 sets) including submission of drawings on a CD
after completion of tank fabrication work as per enclosed
specifications. Note: The drawings should be made in reference to
the attached directional drawings and as per requirement of IS 803
& API 650.
This rate is universally applicable for all tank sizes & capacities.

521 EXTERNAL PAINTING OF PRODUCT TANKS (ALL PRODUCTS M2 1.00 733.00 733.00
INCLUDING ATF & WATER): ZONE-A : FIRST TIME PAINTING
Surface preparation by Blast cleaning and painting of the following
tanks as per details of specification given hereunder and the Techno-
Commercial bid.
Surface preparation by blast cleaning & painting the outside surface
of tank shell and upperside surface of upper deck wind girders,
rolling ladder, roof and shell appurtenances of EXTERNAL FLOATING
ROOF tanks including all fittings and appurtenances etc.; providing
IOC logo with tank writing work as per enclosed specifications (Table-
2) and drawings / Outside surface of tank shell upto and including
curb angle, upperside surface of roof, roof & shell appurtenances of
CONE ROOF tanks (CRVT/IFRVT) including all fittings and
appurtenances etc.; providing IOC logo with tank writing work as per
enclosed specifications (Table-1) and drawings.
Note : 1. Application for External/ Internal painting for all product
tanks shall be carried out by means of AIRLESS SPRAY PAINTING
SYSTEM only. 2. The item rates for above should include provision of
double staging scaffolding with MS pipes, drawing to be approved
by Site-Engineer.
1. Surface Preparation as per SA 2½
2. Primer : P1-Inorganic Zinc Ethyl Silicate: Single Coat: DFT-65-75µ
3. Intermediate Coat : U1-Polyamide cured HB Epoxy MIO : Single
Coat: DFT-100-125µ
4. Finish Coat : F1-Two Pack Acrylic Poly-Urethane(PU) : Single Coat:
DFT-40-50µ
Total Min DFT 215µ
ESTIMATE
SUB: Rate Contract for Carrying Out Repair & Maintenance Work of Tanks and Pipelines at Operating Locations (Terminals, Depots) under Uttar Pradesh State
Office-I.
Ref. No.: UPSO-I/ENG/ M&I/Rate Contract Date 13.3.2018

Sr. No. Discription of work Unit Qty. Rate Amount


522 EXTERNAL PAINTING OF PRODUCT TANKS (ALL PRODUCTS M2 1.00 584.00 584.00
INCLUDING ATF & WATER): ZONE-A : RE-PAINTING / MAINTENANCE
PAINTING
Surface preparation by Blast cleaning and painting of the following
tanks as per details of specification given hereunder and the Techno-
Commercial bid.
Surface preparation by blast cleaning & painting the outside surface
of tank shell and upperside surface of upper deck wind girders,
rolling ladder, roof and shell appurtenances of EXTERNAL FLOATING
ROOF tanks including all fittings and appurtenances etc.; providing
IOC logo with tank writing work as per enclosed specifications (Table-
2) and drawings / Outside surface of tank shell upto and including
curb angle, upperside surface of roof, roof & shell appurtenances of
CONE ROOF tanks (CRVT/IFRVT) including all fittings and
appurtenances etc.; providing IOC logo with tank writing work as per
enclosed specifications (Table-1) and drawings.
Note : 1. Application for External/ Internal painting for all product
tanks shall be carried out by means of AIRLESS SPRAY PAINTING
SYSTEM only. 2. The item rates for above should include provision of
double staging scaffolding with MS pipes, drawing to be approved
by Site-Engineer.
1. Surface Preparation as per St-2 / St-3
2. Primer : P4-Self Primimg HB Epoxy mastic Coating : Single Coat:
DFT- 100-125µ
3. Intermediate Coat : U1-Polyamide cured HB Epoxy MIO : Single
Coat: DFT-100-125µ
4. Finish Coat : F1-Two Pack Acrylic Poly-Urethane(PU) : Single Coat:
523 DFT-40-50µ
EXTERNAL PAINTING OF PRODUCT TANKS (ALL PRODUCTS M2 1.00 674.00 674.00
INCLUDING ATF & WATER) : ZONE-B : FIRST TIME PAINTING
Surface preparation by Blast cleaning and painting of the following
tanks as per details of specification given hereunder and the Techno-
Commercial bid.
Surface preparation by blast cleaning & painting the outside surface
of tank shell and upperside surface of upper deck wind girders,
rolling ladder, roof and shell appurtenances of EXTERNAL FLOATING
ROOF tanks including all fittings and appurtenances etc.; providing
IOC logo with tank writing work as per enclosed specifications (Table-
2) and drawings / Outside surface of tank shell upto and including
curb angle, upperside surface of roof, roof & shell appurtenances of
CONE ROOF tanks (CRVT/IFRVT) including all fittings and
appurtenances etc.; providing IOC logo with tank writing work as per
enclosed specifications (Table-1) and drawings.
Note : 1. Application for External/ Internal painting for all product
tanks shall be carried out by means of AIRLESS SPRAY PAINTING
SYSTEM only. 2. The item rates for above should include provision of
double staging scaffolding with MS pipes, drawing to be approved
by Site-Engineer.
1. Surface Preparation as per SA 2½
2. Primer : P3-Red Oxide Zinc Phosphate Primer : Two Coats: DFT-30-
35µ per coat
3. Finish Coat : F2-Aluminium Finish Paint : Two Coats : DFT-15-20µ
per coat
Total Min DFT 90µ

524 EXTERNAL PAINTING OF PRODUCT TANKS (ALL PRODUCTS M2 1.00 532.00 532.00
INCLUDING ATF & WATER) : ZONE-B : RE-PAINTING/MAINTENANCE
PAINTING
Surface preparation by Blast cleaning and painting of the following
tanks as per details of specification given hereunder and the Techno-
Commercial bid.
Surface preparation by blast cleaning & painting the outside surface
of tank shell and upperside surface of upper deck wind girders,
rolling ladder, roof and shell appurtenances of EXTERNAL FLOATING
ROOF tanks including all fittings and appurtenances etc.; providing
IOC logo with tank writing work as per enclosed specifications (Table-
2) and drawings / Outside surface of tank shell upto and including
curb angle, upperside surface of roof, roof & shell appurtenances of
CONE ROOF tanks (CRVT/IFRVT) including all fittings and
appurtenances etc.; providing IOC logo with tank writing work as per
enclosed specifications (Table-1) and drawings.
Note : 1. Application for External/ Internal painting for all product
tanks shall be carried out by means of AIRLESS SPRAY PAINTING
SYSTEM only. 2.The item rates for above should include provision of
double staging scaffolding with MS pipes, drawing to be approved
by Site-Engineer.
1. Surface Preparation as per St-2/St-3
2. Primer : P3-Red Oxide Zinc Phosphate Primer : Single Coat: DFT-30-
35µ
3. Finish Coat : F2-Aluminium Finish Paint : Two Coats : DFT-15-20µ
per coat
Total Min DFT 60µ
ESTIMATE
SUB: Rate Contract for Carrying Out Repair & Maintenance Work of Tanks and Pipelines at Operating Locations (Terminals, Depots) under Uttar Pradesh State
Office-I.
Ref. No.: UPSO-I/ENG/ M&I/Rate Contract Date 13.3.2018

Sr. No. Discription of work Unit Qty. Rate Amount


525 INTERNAL PAINTING OF PRODUCT TANKS (OTHER THAN ATF): ZONE- M2 1.00 923.00 923.00
A & ZONE-B : FIRST TIME PAINTING & FULL RE-PAINTING
Applicable for CRVT/IFRVT/EFRVT tanks; painting area as per IOC
specification depending on hydro-carbon (product) stored in tank
Note : 1. Application for External/ Internal painting for all product
tanks shall be carried out by means of AIRLESS SPRAY PAINTING
SYSTEM only. 2. The item rates for above should include provision of
double staging scaffolding with MS pipes, drawing to be approved
by Site-Engineer.
1. Surface Preparation as per SA 2½
2. Primer : P1-Inorganic Zinc Ethyl Silicate: Single Coat: DFT- 65-75µ
3. Intermediate Coat : P5-Epoxy Zinc Phosphate : Single Coat: DFT-
35-40µ
4. Finish Coat : F3-Amine adduct cured HB Epoxy Liner : Two coats :
DFT-100-125µ per coat
Total Min DFT 300µ

526 INTERNAL PAINTING OF PRODUCT TANKS (OTHER THAN ATF): ZONE- M2 1.00 657.00 657.00
A & ZONE-B : PATCH RE-PAINTING
Applicable for CRVT/IFRVT/EFRVT tanks; painting area as per IOC
specification depending on hydro-carbon (product) stored in tank
Note : 1. Application for External/ Internal painting for all product
tanks shall be carried out by means of AIRLESS SPRAY PAINTING
SYSTEM only. 2. The item rates for above should include provision of
double staging scaffolding with MS pipes, drawing to be approved
by Site-Engineer.
1. Surface Preparation as per St-3
2. Primer : P2 - Polyamide cured Epoxy Zinc Phosphate : Single Coat:
DFT- 70-75µ
3. Finish Coat : F3-Amine adduct cured HB Epoxy Liner : Two coats :
DFT-100-125µ per coat
Total Min DFT 270µ

527 INTERNAL PAINTING OF PRODUCT TANKS (FOR ATF TANK): ZONE-A M2 1.00 855.00 855.00
& ZONE-B : FIRST TIME PAINTING & RE-PAINTING
Applicable for ATF Storage tank: painting area as per IOC
specification
Note : 1. Application for External/ Internal painting for all product
tanks shall be carried out by means of AIRLESS SPRAY PAINTING
SYSTEM only. 2.The item rates for above should include provision of
double staging scaffolding with MS pipes, drawing to be approved
by Site-Engineer.
1. Surface Preparation as per SA 2½
2. Primer : P2-Polyamide cured Epoxy Zinc Phosphate : Single Coat:
DFT-70-75µ
3. Intermediate Coat : P5-Epoxy Zinc Phosphate : Single Coat: DFT-35-
40µ
4. Finish Coat : F3-Amine adduct cured HB Epoxy Liner : Two coats :
DFT-100-125µ per coat
Total Min DFT 305µ
528 INTERNAL PAINTING OF PRODUCT TANKS (FOR ATF TANK): ZONE-A M2 1.00 657.00 657.00
& ZONE-B : PATCH RE-PAINTING
Applicable for ATF Storage tank: painting area as per IOC
specification
Note : 1. Application for External/ Internal painting for all product
tanks shall be carried out by means of AIRLESS SPRAY PAINTING
SYSTEM only. 2.The item rates for above should include provision of
double staging scaffolding with MS pipes, drawing to be approved
by Site-Engineer.
1. Surface Preparation as per St-3
2. Primer : P2-Polyamide cured Epoxy Zinc Phosphate : Single Coat:
DFT-70-75µ
3. Finish Coat : F3-Amine adduct cured HB Epoxy Liner : Two coats :
DFT-100-125µ per coat
Total Min DFT 270µ
529 INTERNAL PAINTING OF WATER TANKS (FOR FIRE WATER TANK): M2 1.00 973.00 973.00
ZONE-A & ZONE-B : FIRST TIME PAINTING & RE-PAINTING
Applicable for CRVT FIRE WATER STORAGE tanks; painting area as
per IOC specification
Note : 1. Application for External/ Internal painting for all product
tanks shall be carried out by means of AIRLESS SPRAY PAINTING
SYSTEM only. 2. The item rates for above should include provision of
double staging scaffolding with MS pipes, drawing to be approved
by Site-Engineer.
1. Surface Preparation as per SA 2½
2. Primer : P2-Polyamide cured Epoxy Zinc Phosphate : Single Coat:
DFT-70-75µ
3. Finish Coat : F4-Solvent less HB Epoxy Liner : Two coats : DFT-
250µ per coat
Total Min DFT 575µ
ESTIMATE
SUB: Rate Contract for Carrying Out Repair & Maintenance Work of Tanks and Pipelines at Operating Locations (Terminals, Depots) under Uttar Pradesh State
Office-I.
Ref. No.: UPSO-I/ENG/ M&I/Rate Contract Date 13.3.2018

Sr. No. Discription of work Unit Qty. Rate Amount


530 INTERNAL PAINTING OF WATER TANKS (FOR FIRE WATER TANK): M2 1.00 858.00 858.00
ZONE-A & ZONE-B : PATCH RE-PAINTING
Applicable for CRVT FIRE WATER STORAGE tanks; painting area as
per IOC specification
Note : 1. Application for External/ Internal painting for all product
tanks shall be carried out by means of AIRLESS SPRAY PAINTING
SYSTEM only. 2. The item rates for above should include provision of
double staging scaffolding with MS pipes, drawing to be approved
by Site-Engineer.
1. Surface Preparation as per St-3
2. Primer : P2-Polyamide cured Epoxy Zinc Phosphate : Single Coat:
DFT-70-75µ
3. Finish Coat : F4-Solvent less HB Epoxy Liner : Two coats : DFT-
250µ per coat
Total Min DFT 575µ
531 INTERNAL PAINTING OF INTERNAL PONTOON SURGACE IN EFR M2 1.00 155.00 155.00
TANKS : ZONE-A & ZONE-B : FIRST TIME PAINTING & RE-PAINTING
Applicable for EFR PRODUCT tank
1. Surface Preparation as per St-2
2. Primer : P2-Polyamide cured Epoxy Zinc Phosphate : Single Coat:
DFT-70-75µ
Total Min DFT 70µ

532 UNDERSIDE OF TANK BOTTOM PLATE : ZONE-A & ZONE-B : FIRST M2 1.00 656.00 656.00
TIME PAINTING
Applicable for NEW CR/IFR/FR PRODUCT & WATER tank
1. Surface Preparation as per SA 2½
2. Primer : P1-Inorganic Zinc Ethyl Silicate : Single Coat: DFT- 65-75µ
3. Finish Coat : F3-Amine Adduct cured HB Epoxy Liner : Two coats :
DFT- 100-125µ per coat
Total Min DFT 265µ

533 Supply, handling and fabrication of central roof vent for as per API LS 1.00 141532.00 141,532.00
650 for IFR tank. The job shall be included providing 10" SCH 40
seamless pipe with provision of 10" flange and and elbow with SS
wire net at the end of 10" central vent. The center circulation vent
shall be with a minimum net open area of 30,000 mm2 (50 in.2) shall
be provided at the center of the fixed roof or at the highest
elevation possible on the fixed roof. It shall have a weather cover
and shall be provided with a corro- sion-resistant Coarse-mesh
screen of SS make. The rate of central vent shall be inclusive of
trasportation, installation and octroi and necssary inspection and
testing.

534 Supply, handing and fabrication of Peripheral circulation vents as LS 1.00 33139.00 33,139.00
per drw no. IOCL-HO-IFR-RV-01 and shall be located on the tank
roof (unless otherwise specified by the Purchaser of IFR) and meet
the requirements of H.5.3.3 of design code of API 650 APPENDIX , so
that they are above the seal of the internal floating roof when the
tank is full. The maximum spac- ing between vents shall be 10 m (32
ft), based on an arc measured at the tank shell, but there shall not
be fewer than four equally-spaced vents. The venting shall be
distributed such that the sum of the open areas of the vents located
within any 10 m (32 ft) interval is at least 0.2 m2 (2.0 ft2). These
vents shall be covered with a 3 mm corrosion-resistant aluminium
plate. The rate of central vent shall be inclusive of trasportation,
installation and octroi and necssary inspection and testing.

535 Degassing & Desludging into secondary containment like concrete or EA 1.00 154100.00 154,100.00
earth pit, barrels or tank truck etc and cleaning of the bottom of
floating roof along with support legs, bottom, roof and shell plates
upto resting position of roof in case of FR Tanks and bottom and
shell plates upto 1.5 m high of CR Tanks by hydrojetting method
with all tool sand tackles and explosion proof degassing unit / sludge
pumps etc.
Note : For above item, the approved sub vendor shall directly report
to the Location Incharge and the entire cleaning and degassification
process shall be done under supervision of Operating personnel of
Terminal. Hot work shall commence only after tank is certified as
degassed by the Location Icharge
Water @ 18 lpm and electricity 3 phase for this item shall be
provided by IOCL
ESTIMATE
SUB: Rate Contract for Carrying Out Repair & Maintenance Work of Tanks and Pipelines at Operating Locations (Terminals, Depots) under Uttar Pradesh State
Office-I.
Ref. No.: UPSO-I/ENG/ M&I/Rate Contract Date 13.3.2018

Sr. No. Discription of work Unit Qty. Rate Amount


536 Conducting hydrotest of the nozzles/manholes replaced by EA 1.00 22472.00 22,472.00
providing test arrangement as per given Drg no. WR/M&I/01. Scope
includes supply and welding of box arrangement as shown in the
sketch (either of the two options). In case option 2 is followed, the
box will have to be cut carefully without damaging the shell and
making area ground smooth after the test. Instead of square box,
circular box of suitable dia to cover the weld joint of nozzle to shell
will also suffice. The scope includes making arrangement of filling
water into the box, providing pressure gauge, hand pump, blind
nozzle etc as required. The hydrotest will be carried out at max 1.5
times the hydrostatic pressure i.e. 3.5 kg/cm2.

537 Dismantling of MS plates in bottom, shell & roof of TON 1.00 30345.00 30,345.00
CRVT/FRVT/IFRVT tanks either partly or in full as directed, by
gas/hacksaw cutting from the existing weld seams & removing the
MS plates from the tank by mechanical means, with utmost
precaution and neatly straightening and storing at place indicated
by site engineer anywhere in IOC premises, complete, irespective of
lead and lift as directed. The rate includes the cost of labour, gases,
providing necessary temporary supports, safe walk ladder, safety
precautions etc., all necessary equipments, all necessary structures,
clamps, suitable non-combustible material wedges, etc. complete to
the satisfaction of site-in-charge. Plan area and average thickness of
roof plates will be considered for calculating the qty of dismantled
plates, and weight of appurtenances will not be considered
seperately, and no extra payment for the same will be made.
Note: Contractor has to submit the dismantling methodology clearly
stating the restraining techniques to be involved so that circularity
of the undamaged shell plates remains undisturbed, prior to
commencement of work and has to get it approved from IOCL.
Plates and structures, apputenances should be dismantled with
utmost care as these are to be reutilised.

538 Dismantling and reconnecting, if any after completion of welding, of EA 1.00 6378.00 6,378.00
existing catwalks connected to roof, pipelines connected to tank
body etc. including isolation during welding & cutting etc. and re-
connection after completion of work.

539 Repairs to exisitng damaged roof structurals of CRVT/FRVT/IFRVT MT 1.00 21940.00 21,940.00
tanks such as rafters, griders including providing temporary
supports, providing derricks for dismantling, handling, lowering,
cutting/dismantling of member joints, re-erection/re-connecting of
the same to bring its original shape/position etc complete. supply of
additional roof structure element to replace damaged/twisted
members will be paid separately.

540 Supplying and providing of 80mm dia Gauge Hatch on roof/gauge EA 1.00 8776.00 8,776.00
well of CRVT/FRVT/IFRVT tanks using 80 mm dia nominal pipe
welded with slipon flange on top of it including supplying and
providing reinforcing plate etc. complete as per our specifications
and B&R drawing.
541 Supplying and providing of 100mm dia Gauge Hatch on roof/gauge EA 1.00 30716.00 30,716.00
well of CRVT/FRVT/IFRVT tanks using 100 mm dia nominal pipe
welded with slipon flange on top of it including supplying and
providing reinforcing plate etc. complte as per our specifications and
B&R drawing.
542 Repair of Defective Weld Joints in tank Bottom plates: M 1.00 8480.00 8,480.00
All weld defects in Lap joints in Shell plates should be removed by
fine grinding and rewelding to be carried out to ensure no further
weld defects. Welding to be carried out using E6013 electrode

543 Rolling Ladder Repair in existing EFR Tank: LS 1.00 25618.00 25,618.00
Carrying out repairs of rolling ladder by welding of hinges to ladder
structure at either end/or putting cotter pins, correcting alignment
of rolling ladder steps by adjusting the link etc

544 Rolling Ladder Repair in existing EFR Tank: LS 1.00 25618.00 25,618.00
Removing washer on One Side of rolling ladder wheel and fixing on
other side and adjusting position of wheel so as to make it centric
including providning temporary support to ladder etc as required.

545 Rolling Ladder Repair in existing EFR Tank: Brass bars brazed to the LS 1.00 6360.00 6,360.00
rolling ladder wheels to be provided
546 Rolling Ladder Repair in existing EFR Tank: M 1.00 3180.00 3,180.00
Supply and providing proper copper bonding connection should be
provided between the roof and rolling ladder with earthing wire
cable of size 50mm SQ PVC insulated copper wire cable, including
replacement of damaged lugs etc as required.
ESTIMATE
SUB: Rate Contract for Carrying Out Repair & Maintenance Work of Tanks and Pipelines at Operating Locations (Terminals, Depots) under Uttar Pradesh State
Office-I.
Ref. No.: UPSO-I/ENG/ M&I/Rate Contract Date 13.3.2018

Sr. No. Discription of work Unit Qty. Rate Amount


547 Roof Appurtenances: Supply,fabrication, installation,welding, heat -
treatment if required including fabrication & fixing of nozzle
necks, etc.including preparation of drawings,supply of gases
electrodes and other consumables, supply and fixing of bolts, nuts
and gaskets of approved make wherever required etc & all labour
material for completing the work as per drawings, codes/IOC
specifications. Site engineer's instructions.
NOTE: The new dip hatch is to be fixed in such a way that it is
exactly above the datum plate and the reference ht. is not altered.

548 a) Roof manhole-500 mm dia as per drg no.BR/CR/277 EA 1.00 18698.00 18,698.00

549 b) 220 MM dia gauge hatch with spark proof cover as per drg.no EA 1.00 23376.00 23,376.00
BR/CR/273,274,275,276
550 c) 250 mm dia free vent nozzle as per drg no. BR/CR/278 Rev-1 EA 1.00 12751.00 12,751.00

551 d) Temperature hatch with nozzle of 80 mm dia as per drg.no EA 1.00 5845.00 5,845.00
BR/CR/279.
552 e) Sample hatch with nozzle of 100 mm dia as per drg no.BR/CR/277 EA 1.00 5845.00 5,845.00

553 f) gauge hatch 150 MM dia as per drg no BR/70993/43 Rev-0 EA 1.00 10600.00 10,600.00

554 g) Additional nozzle 50 mm dia for level switch with Slip on flange as EA 1.00 7420.00 7,420.00
per drg no BR/70993/43 Rev-0
555 Provision of 1 no rim vent of 4" dia as per B&R drawing and EA 1.00 29098.00 29,098.00
providing 6"x4" reducer for one (existing) vent
556 REPLACEMENT OF EXISTING SHELL MANHOLE & SHELL NOZZLE -
NECK PLATES WITH NEW NECK PLATE CONFORMING TO API-650:
Scope includes careful removal of welding between nozzles and
shell plates / reinforcement plate by light pencil grinding without
damaging them, rewelding of radio-graphic quality, radiography of
welded joints, DP test of weld between each nozzle and
reinforcement plate/shell plate to be done after root run and after
complete welding, pneumatic test of reinforcement plate / shell
plate to be done after welding completion at 15 psi and touch-up
painting of welded areas with zinc rich primer and
Aluminium/Synthetic enamel finish paint of same shade as
existing on the tank. Internal surface of manhole neck will be
painted with one coat of zinc rich primer and two coats of epoxy
tank liner, as per IS 803 and B&R drawings. In case the weld joint is
found defective, rectification & testing will be done free of cost.
All safety precautions to be adhered during hot work. Scope
includes supply of all the materials, tools and tackles. Steel plates
used shall conform to IS 2062 (for manhole neck). Material
specification for nozzle neck shall be SA -106 Gr. B when size is
upto and including 250 mm. Neck of nozzle shall be fabricated
from plates of material specificaion IS:226/2062 when the size is
more than 250mm. Scope of work also includes supply of flanges,
making flange (of thickness 16mm) joints for shell manholes of 750
mm size from plates including supply of all the materials all
complete, in case of damage to the same during gouging. All the
scrapped/dismantled material to be the property of the
contractor.
557 Shell Manhole Neck Plate for Shell Manhole dia. 750mm -
558 5mm thk. EA 1.00 59575.00 59,575.00

559 6mm thk EA 1.00 71490.00 71,490.00

560 8mm thk EA 1.00 95320.00 95,320.00

561 10mm thk EA 1.00 119150.00 119,150.00

562 12mmthk EA 1.00 142977.00 142,977.00

563 14mm thk EA 1.00 150444.00 150,444.00

564 16mm thk EA 1.00 153521.00 153,521.00

565 18mm thk EA 1.00 172720.00 172,720.00

566 Replacement of Shell Nozzle Neck with suitable pipe Plate as per -
API-650
567 600mm dia of neck thickness 12.7mm (SCH-XS) EA 1.00 91000.00 91,000.00

568 500mm dia of neck thickness 12.7mm (SCH-XS) EA 1.00 76000.00 76,000.00

569 450mm dia of neck thickness 12.7mm (SCH-XS) EA 1.00 68143.00 68,143.00

570 400mm dia of neck thickness 12.7mm (SCH-XS) EA 1.00 60570.00 60,570.00

571 350mm dia of neck thickness 12.7mm (SCH-XS) EA 1.00 53000.00 53,000.00
ESTIMATE
SUB: Rate Contract for Carrying Out Repair & Maintenance Work of Tanks and Pipelines at Operating Locations (Terminals, Depots) under Uttar Pradesh State
Office-I.
Ref. No.: UPSO-I/ENG/ M&I/Rate Contract Date 13.3.2018

Sr. No. Discription of work Unit Qty. Rate Amount


572 300mm dia of neck thickness 12.7mm (SCH-XS) EA 1.00 45428.00 45,428.00

573 250mm dia of neck thickness 12.7mm (SCH-XS) EA 1.00 42400.00 42,400.00

574 200mm dia of neck thickness 12.7mm (SCH-XS) EA 1.00 37100.00 37,100.00

575 150mm dia of neck thickness 10.97mm (SCH-XS) EA 1.00 31800.00 31,800.00

576 100mm dia of neck thickness 8.56mm (SCH-XS) EA 1.00 21200.00 21,200.00

577 80mm dia of neck thickness 7.62mm (SCH-XS) EA 1.00 13568.00 13,568.00

578 50mm dia of neck thickness 5.54mm (SCH-XS) EA 1.00 6360.00 6,360.00

579 Supply, fabrication, installation, welding, heat treatment if -


required including fabrication & fixing of cover plates on shell
manholes, etc. including preparation of drawings, supply of gases,
electrodes and other consumables, supply and fixing of bolts, nuts
conforming to ASTM A193 GR.B7/A194 GR.2H and gaskets of
approved make wherever required etc. and all labour material for
completing the work as per drawings, codes / IOC specifications
and site engineer's instructions (As per B&R drawing no.
BR/CR/221)

580 a) upto 984 mm OD, 12 mm thick EA 1.00 42532.00 42,532.00

581 b) upto 984 mm OD, 14 mm thick EA 1.00 49621.00 49,621.00

582 c) upto 984 mm OD, 16 mm thick EA 1.00 56710.00 56,710.00

583 d) upto 984 mm OD, 18 mm thick EA 1.00 63798.00 63,798.00

584 e) upto 984 mm OD, 20 mm thick EA 1.00 70887.00 70,887.00

585 f) upto 984 mm OD, 22 mm thick EA 1.00 77980.00 77,980.00

586 Supply, fabrication, installation, welding, heat treatment if required EA 1.00 5830.00 5,830.00
including fabrication & fixing of cover plates of 6 mm thickness and
650 mm dia in roof manholes, etc. including preparation of
drawings, supply of gases, electrodes and other consumables, supply
and fixing of bolts, nuts and gaskets of approved make wherever
required etc. and all labour material for completing the work as per
drawings, codes / IOC specifications and site engineer's instructions
(As per B&R drawing no. BR/CR/277)

587 Replacement of damaged Legs in EFR Tanks: EA 1.00 54600.00 54,600.00


Item includes cutting the corroded leg pipes in the double deck
floating roof tank, removing the existing pad plates by grinding and
providing new sleeve leg pipes of 80 mm (Schedule 40 thickness)
and inner leg pipe of 65 mm dia. (thickness shall be as per schedule
80 ), necessary pad platesand welding the entire arrangement for
trouble free operatio. The leg pipe sleeve to be braised with brass
strip for spark free opration. (refer B&R Drawing No. BR/FR/252 Rev-
0)
The entire job shall be as per specification & direction of IOCL.

588 Provision of additional Legs in EFR Tanks: EA 1.00 54000.00 54,000.00


Providing new sleeve leg pipes of 80 mm (Schedule 40 thickness)
and inner leg pipe of 65 mm dia. (thickness shall be as per schedule
80 ), necessary pad platesand welding the entire arrangement for
trouble free operatio. The leg pipe sleeve to be braised with brass
strip for spark free opration. (refer B&R Drawing No. BR/FR/252 Rev-
0)
The entire job shall be as per specification & direction of IOCL.

589 Dismantling and re-installation charges for complete mechanical M 1.00 1180.00 1,180.00
seal/foam seal "Installation charges for complete mechanical seal
(primary and secondary) supply of required labour and removal of
existing foam seal including weather shield, foam, seal cover,
holding down bars, nuts/bolts etc. and stacking the same at the
designated place inside the terminal. Dismantled material shall be
the property of IOCL. The item includes charges for supervision by
manufacturer, if required.
Modification if any of the rim angle (by hot work, drilling and supply
of material including rim angle, if required) for fixing of new
mechanical also is included in the scope of contractor. "

590 Testing of weld joints by Chalk- Kerosene test (for bottom /annular M 1.00 85.00 85.00
plate & shell palte joint in vertical oil tanks)
ESTIMATE
SUB: Rate Contract for Carrying Out Repair & Maintenance Work of Tanks and Pipelines at Operating Locations (Terminals, Depots) under Uttar Pradesh State
Office-I.
Ref. No.: UPSO-I/ENG/ M&I/Rate Contract Date 13.3.2018

Sr. No. Discription of work Unit Qty. Rate Amount


591 Supplying, fabricating, welding, additional length of support pipe 40 EA 1.00 337.00 337.00
mm dia, sch 40 for proper functioning and additional auto bleeder
vent to be provided as per B&R drawing no. BR/FR/265

592 Drilling tell tale hole on reinforcement pads of manholes of specified EA 1.00 449.00 449.00
dia without damaging the shell.
593 Supplying and welding 2 nos handles of 12 mm round bars bend in U EA 1.00 169.00 169.00
shape on each pontoon inspection hatch cover.
594 Providing siphon breaker on top portion of expansion relief line LS 1.00 2753.00 2,753.00
above gauge well housing top flange by suitably modifying existing
Tee on 25 mm dia line.
595 Supplying, fixing of existing brass sleeve (ring in two halves) of LS 1.00 19326.00 19,326.00
50mm depth x 5mm thick in the top and bottom inner
circumference of gauge pipe sleeve by brazing and / or fixing to the
nut/bolts of gauge well sleeve by means of strips.

596 Supplying providing 6 mm thick, 2 ply neoprene gasket as per EA 1.00 1404.00 1,404.00
drawing in between flanges of existing 400 mm dia gauge well
housing, providing nut/bolts etc as required.
597 Supplying, fabricating, providing cover with mesh for central drain of EA 1.00 23595.00 23,595.00
Double Deck EFR tank as per B&R drawing No. BR/FR/283

598 Providing stitch welding on inner side of foam dam on roof top LS 1.00 14382.00 14,382.00
wherever the same is not provided and reducing size of slots on
bottom of foam dam as required.
599 Supplying, fabricating, welding, erecting foam dam using 5 mm MS KG 1.00 95.00 95.00
plates (IS 2062) of 600 mm height at 600 mm from the shell internal
surface on the upper deck, stitch welding, painting with 2 coats of
red oxide zinc chromate primer and 2 coats of synthetic enamel
paint etc.
600 Cleaning and carrying out welding of joints of required size (5mm - M 1.00 1272.00 1,272.00
8mm) wherever left out including wind girder, inside
pontoons(bulkheads to upper deck plate) etc after surface
preparation by grinding if required.
601 Repair of defective weld joints by grinding/gouging to required M 1.00 2650.00 2,650.00
depth and rewelding by qualified welder to required length. After
the root run repair the weld joint will be subjected to Dye
Penetration test. Cost of Dye penetration test will be paid
separately. In case after repair, the weld joint is again found
defective, rectification & testing will be done free of cost.

602 Removal of insulationof the tank. Item includes safe removal of M2 1.00 424.00 424.00
aluminium cladding, complete insulating material and stacking it at a
place as per instruction of site engineer. Removed aluminium
cladding will be the property of the contractor. Contractor should
quote rate deducting the rate of aluminium cladding (scrap).

603 Repair of holes on roof plates with pad plates, 250 mm x 250 mm EA 1.00 795.00 795.00
including vacuum box testing of the weld joints after providing of
patch plates. Item includes supply of 5 mm plates as required.

604 Overflow nozzle for water tank: Supply, fabrication, erecting of 100 EA 1.00 25000.00 25,000.00
mm dia NB nozzle of nominal wall thickness of 8.56 mm (SCH-XS) for
overflow line in shell 200 mm dia below lowest member of roof
trusses including external painting. Supply, welding of flange on
either end will be paid separately.
Item includes cutting of the previous over flow nozzle, if any,
providing patch plate on shell to close the opening.

605 Overflow nozzle for water tank: Supply, fabrication, erecting of 80 EA 1.00 21200.00 21,200.00
mm dia NB nozzle of nominal wall thickness of 7.62 mm (SCH-XS) for
overflow line on shell 200 mm dia below lowest member of roof
trusses including external painting. Supply, welding of flange on
either end will be paid separately.
Item includes cutting of the previous over flow nozzle, if any,
providing patch plate on shell to close the opening.

606 Pontoons compartments to be tested individually with air pressure LS 1.00 27030.00 27,030.00
max. 0.5 Kg/sqcm by sealing compartment joints on top and hatch &
checking by means of soap water on all joints to ensure the
pontoons are free from pinholes/ leakages/ seepage etc. before re-
commissioning the tank.
607 Replacement of existing Central Drain 100 NB Sch 80 Pipe inside LS 1.00 30210.00 30,210.00
pontoon.
Item includes dismantling/cutting of existing 100 NB pipe,
reinforcement pad plates, etc. and supply, fabrication, welding &
testing of new 100 NB sch 80 pipe, reinforcement pad plates,
stiffners, etc. as drg. no.: per BR/FR/295.
ESTIMATE
SUB: Rate Contract for Carrying Out Repair & Maintenance Work of Tanks and Pipelines at Operating Locations (Terminals, Depots) under Uttar Pradesh State
Office-I.
Ref. No.: UPSO-I/ENG/ M&I/Rate Contract Date 13.3.2018

Sr. No. Discription of work Unit Qty. Rate Amount


608 Corroded Emergency drain pipe to be replaced with new pipe as per LS 1.00 37948.00 37,948.00
B&R drawing ref. BR/FR/267. DP test of root run of welding should
be carried out and vacuum box testing of any new welding in lower
deck plate should be carried out at no extra cost.

609 Removal of metal cleats provided in the gauge well sleeve by gas LS 1.00 22048.00 22,048.00
cutting, Supply and providing brass sleeves of 50 mm X 5 mm size
both on top and bottom of gauge well sleeve pipe. Item includes
supply of all the required instruments and machinary.

610 Welding of shell plate with bottom wherever missing, welding of Pad Inch 1.00 148.00 148.00
plates already provided on the bottom for roof legs with E-6013
electrode grinding and welding lower deck plates with 1no. of leg
sleeve and 1 manhole neck from inside the tank. Welding between 1
step and flat of rolling ladder. Chalk kerosene test of shell and
bottom flats to be done at no extra cost.

611 Replacement of existing Tank vents: EA 1.00 46110.00 46,110.00


Dismantling of existing air vents of 6 inch dia by gas cutting and
stacking at designated place within terminal, supply, fabrication,
handling and fixing air vents of 10 inch LRB type as per IOCL Drg. Ref.
BR/CR/278 Rev-1 including providing new nozzle on roof of 250 mm
dia, SO flanges as required etc. Dismantled air vent material will be
property of party and is to be taken by them. Rebate towards cost of
scrap to be considered while quoting for this item.

612 Taking radiographs of tank weld joints (T joints/horizontal/vertical EA 1.00 1206.00 1,206.00
joint) using film size 4" x 8" or 3" x 12 " as required.
Radiography inspection on tank joints of all types and thickness
including providing all necessary equipment and safe double
scaffolding required to perform the work as per specifications and
instruction of Site Engineer. The radiographs shall be submitted to
the engineer in charge at site/ third party inspecting agency.
Retaking of radiography due to defective welds/defective films/
defective workmanship etc. will be to contractor's account.

613 Submission of radiographs to Third Party Inspection EA 1.00 4240.00 4,240.00


Agency(PDIL/BVIS/DNV/TUV) and getting evaluation report duly
certified by qualified inspector(ASNT Level II)
614 Supply of sweet water for floatation testing/hydrotesting of KL 1.00 289.00 289.00
CR/EFR/IFR vertical tank. Water is to be filled till full height of tank.
Payment will be made for total quantity of water mathematically or
arithmatically calculated, as per size of tank.

615 Supplying, providing of safe tubular double stage (box type) M2 1.00 371.00 371.00
scaffolding outside the tank as per specification & satisfaction of
location in charge. After use, the same shall be dismantled and taken
away by the contractor. Payments shall be made for actual area of
scaffolding provided based on requirement. Area of scaffolding will
be measured on the basis of actual height of scaffolding provided
multiplied by actual average length of scaffolding provided.

616 Designing, supplying,fabricating,welding, bolting, riveting, M2 1.00 1219.00 1,219.00


assembling and erecting in position temporary required local 8.0 M
highfire screen wall aound the tank with GI sheets with cross
supports etc as per alignment shown by site Engineer, maintaining
same till the completion of entire work and dismantling the entire
screen wall carting away the dismantled materials from site redoing
the entire existing surface to the original condition etc complete.The
8M high fire screen wall including the foundation is to be designed
and approved by a '' licensed structural Engineer'' and should be
suitable for local soil bearing capacity, wind speed etc.

617 Erecting temporary mobile fire screen wall around the place where M2 1.00 1360.00 1,360.00
hot works is carried out using GI sheets or non-flammable asbestos
sheets. Payment will be made for total area of sheets provided. The
screen needs to be moved from place to place at no extra cost.

618 Conducting Dye penetration test on the new weld joints (shell to M 1.00 426.00 426.00
bottom plate, pad plates for roof supports, lower deck plate with leg
sleeve, manhole neck, rolling ladder etc) after welding.

619 Conducting Vacuum Box testing of roof/bottom plates at specified LS 1.00 21200.00 21,200.00
pressure(vacuum) including supply of all required equipments like
vacuum box, vacuum pump etc. complete as per instruction of site-
in-charge.
ESTIMATE
SUB: Rate Contract for Carrying Out Repair & Maintenance Work of Tanks and Pipelines at Operating Locations (Terminals, Depots) under Uttar Pradesh State
Office-I.
Ref. No.: UPSO-I/ENG/ M&I/Rate Contract Date 13.3.2018

Sr. No. Discription of work Unit Qty. Rate Amount


620 Conducting weld inspection of all weld joints on shell plate by wet M 1.00 636.00 636.00
Fluorescent Magnetic Particle with UV lamp including supervision by
qualified inspector with ASNT level 2 certification. Note: Scaffolding
will be paid separately.

621 Carrying out bottom floor scanning of storage tanks using either Low M2 1.00 162.56 162.56
Frequency Electromagnetic Testing (LEFT) or Magnetic Flux Leakage
(MFL) technique to identify corrosion, pitting, thickness loss,
perforation of products as well as soil side of bottom plates.
Ultrasonic thickness of the inaccessible areas where LEFT / MFL is
restricted. Confirmation and sizing of defects by use of UT gauge.
Submission of reports (plate wise) for wall loss greater than 20% as
per enclosed scope of work

622 "Supply and installation of CP System (by Sacrificial product side M2 1.00 860.00 860.00
anode) - For Product Tanks
The job includes drawing, design, detailed Engineering, supply of
material, installation, testing and commissioning of SACRIFICIAL
CATHODIC PROTECTION for the mitigation of Internal corrosion in
bottom plate of product Tank. The main activities involved are:Basic
Site Survey, Design, Detail Engineering and Supply of
materialfollowed by installation, testing and commissioning and
handing over theCP System as per detailed specifications enclosed.
The SACRIFICIAL CATHODIC PROTECTION design shall be based as
per NACE Standard RP-01-96, RP-0575, RP-0193-93 and corrosion
control in petroleum production, TPC Publication No. 05 and Indian
Standard IS8062 (1976): Code of Practice for C.P of Steel
Structures." Please Note: Drawing/design for providing sacrificial
cathodic protection systemin product tanks to be done only after
site survey/visit.

623 Supply and installation of CP System - For Water Tanks - M2 1.00 750.00 750.00
The job includes drawing, design, detailed Engineering, supply of
material, installation, testing andcommissioning of SACRIFICIAL
CATHODIC PROTECTION for the mitigation of Internal corrosion in
bottom, shell, roof plate & roof structural of Water Tank. The main
activities involved are:Basic Site Survey, Design, Detail Engineering
and Supply of materialfollowed by installation, testing and
commissioning and handing over theCP System as per detailed
specifications enclosed.
The SACRIFICIAL CATHODIC PROTECTION design shall be based as
per NACE Standard RP-01-96, RP-0575, RP-0193-93 and corrosion
control in petroleum production, TPC Publication No. 05 and Indian
Standard IS8062 (1976): Code of Practice for C.P of Steel
Structures." Please Note: Drawing/design for providing sacrificial
cathodic protection system in fire water tanks to be done only after
site survey/visit.

624 CIVIL WORKS


625 Earth work in surface excavation not exceeding 30 cm in depth but M2 1.00 52.48 52.48
exceeding 1.5 m in width as well as 10 sqm on plan including
disposal of excavated earth within site and lift upto 1.5 m, disposed
soil to be levelled and neatly dressed

626 Clearing grass and removal of the rubbish outside site premises and M2 1.00 3.61 3.61
at unobjectionable place
627 Clearing jungle including uprooting of rank vegetation, grass, brush M2 1.00 7.13 7.13
wood, trees and saplings of girth upto 30cm measured at a height of
1m above ground level and removal of rubbish outside the site and
to unobjectionable place

628 Earth work in rough excavation, banking excavated earth in layers M3 1.00 423.73 423.73
not exceeding 20 cm in depth, breaking clods watering, rolling each
layer with ½ tonne roller or wooden or steel rammers, and rolling
every 3rd and top-most layer with power roller of minimum 8
tonnes and dressing up in embankments for roads, flood banks,
marginal banks and guide banks or filling up ground depressions,
within site and lift upto 1.5 m for ALL KINDS OF SOIL

629 Earth work in excavation by mechanical means (Hydraulic -


excavator) / manual means over areas (exceeding 30cm in depth.
1.5m in width as well as 10 sqm on plan) including disposal of
excavated earth within and outside site to unobjectionable place,
disposed earth to be levelled and neatly dressed.

630 i) All kinds of Soil M3 1.00 124.72 124.72


631 ii) Ordinary rock M3 1.00 218.9 218.90
632 iii) Hard Rock(Requiring Blasting) M3 1.00 389.47 389.47
633 iv) Hard Rock (Blasting Prohibited) chiesel/pneumatic drilling M3 1.00 613.77 613.77
ESTIMATE
SUB: Rate Contract for Carrying Out Repair & Maintenance Work of Tanks and Pipelines at Operating Locations (Terminals, Depots) under Uttar Pradesh State
Office-I.
Ref. No.: UPSO-I/ENG/ M&I/Rate Contract Date 13.3.2018

Sr. No. Discription of work Unit Qty. Rate Amount


634 Deduct for disposal of soil not levelled AND NOT neatly dressed M3 1.00 37.58 37.58
against item no. 1005a,1005b,1005c,1005d
635 Earth work in excavation by mechanical means (Hydraulic -
excavator) / manual means in foundation trenches or drains (not
exceeding 1.5 m in width or 10 sqm on plan) including dressing of
sides & ramming of bottoms, lift upto 1.5 m, including getting out
the excavated soil & disposal of surplus excavated soil as
directed within or outside the site at an unobjectionable place.

636 All kinds of Soil M3 1.00 164.78 164.78


637 Ordinary rock M3 1.00 273.16 273.16
638 Hard Rock(Requiring Blasting) M3 1.00 461.51 461.51
639 Hard Rock(Blasting Prohibited) chiesel/pneumatic drilling M3 1.00 650.31 650.31
640 Extra for excavation for every additional lift of 1.5m or part thereof M3 1.00 16.93 16.93
in ALL KIND OF SOIL
641 Extra for excavation for every additional lift of 1.5m or part thereof M3 1.00 30.05 30.05
in HARD ROCK
642 Excavating trenches of required width for pipes, cables, etc -
including excavation for sockets & dressing of sides, ramming of
bottoms,depth upto 1.5m including getting out excavated soil &
then returning the soil as required, in layers not exceeding 20 cm
in depth including consolidating each deposited layer by ramming,
watering, etc. and disposing surplus excavated soil as directed,
within or outside site at unobjectionable place IN ALL KIND OF
SOILS
643 i) Pipes,cables etc. not exceeding 80mm dia M 1.00 136.71 136.71
644 ii) For extra depth of >1.5m < 3m for dia upto 80mm M 1.00 173.61 173.61
645 iii) For extra depth of >3m < 4.5m for dia upto 80mm M 1.00 430.63 430.63
646 iv) Pipes, Cable etc. > 80mm < 300m dia M 1.00 223.26 223.26
647 v) For extra depth of >1.5m < 3m for dia 80 to 300mm M 1.00 283.53 283.53
648 vi) For extra depth of >3m < 4.5m for dia 80 to 300mm M 1.00 703.26 703.26
649 vii) Pipes,cables etc.> 300mm < 600mm dia M 1.00 348.57 348.57
650 viii)For extra depth of >1.5m < 3m for dia300 to 600mm M 1.00 442.69 442.69
651 ix) For extra depth of >3m < 4.5m for dia 300 to600mm M 1.00 1098.01 1,098.01
652 Excavating trenches of required width for pipes, cables, etc -
including excavation for sockets, depth upto 1.5m including getting
out excavated material ,returning the soil as required in layers in
not exceeding 20 cm in depth including consolidating each
deposited layer by ramming, watering, etc. & stacking serviceable
material and disposing unserviceable material as directed outside
site at an unobjectionable place IN ORDINARY ROCK

653 i) Pipes,cables etc. not exceeding 80mm dia M 1.00 192.61 192.61
654 ii) For extra depth of >1.5m < 3m for dia upto 80mm M 1.00 198.39 198.39
655 iii) For extra depth of >3m < 4.5m for dia upto 80mm M 1.00 489.22 489.22
656 iv) Pipes, Cable etc. > 80mm < 300m dia M 1.00 476.91 476.91
657 v) For extra depth of >1.5m < 3m for dia 80 to 300mm M 1.00 491.22 491.22
658 vi) For extra depth of >3m < 4.5m for dia 80 to 300mm M 1.00 1211.35 1,211.35
659 vii) Pipes,cables etc.> 300mm < 600mm dia M 1.00 548.8 548.80
660 viii)For extra depth of >1.5m < 3m for dia300 to 600mm M 1.00 565.27 565.27
661 ix) For extra depth of >3m < 4.5m for dia 300 to600mm M 1.00 1393.97 1,393.97
662 Filling available excavated earth (excluding rock) in trenches, plinth, M3 1.00 124.53 124.53
sides of foundations etc. in layers not exceeding 20cm in depth,
consolidation each deposited layer by ramming and watering, within
premises and lift upto 1.5m

663 Supply & filling imported earth, in plot,trenches, plinth, sides of M3 1.00 453.84 453.84
foundations etc. in layers not exceeding 20cm in depth, each
deposited layer by ramming and watering.
664 Supplying and Local sand filling within the grading zone V of fine M3 1.00 908.82 908.82
aggregates specified in table 3.1 , clause 3.1.3 of attached
specifications, in plinth, under floors etc. in layers not exceeding
20cm in depth, each deposited layer to be compacted by ramming
watering and dressing complete
665 Providing and laying in position cement concrete of specified grade -
excluding cost of centering and shuttering - All work up to plinth
level :
666 i) 1:1:2(1 Cement : 1 Coarse Sand : 2 Graded stone aggregate of M3 1.00 7,234.68 7,234.68
20mm)
667 ii)1:1½:3(1 Cement :1½ Coarse Sand: 2 Graded stone aggregate of M3 1.00 5,866.97 5,866.97
20mm)
668 iii)1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of M3 1.00 5,428.58 5,428.58
20mm)
669 iv)1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of M3 1.00 5,337.97 5,337.97
40mm)
670 v)1:3:6(1 Cement : 3 Coarse Sand : 6 Graded stone aggregate of M3 1.00 4,879.04 4,879.04
20mm)
671 vi)1:3:6(1 Cement : 3 Coarse Sand : 6 Graded stone aggregate of M3 1.00 4,767.68 4,767.68
40mm)
672 vii)1:3:6(1 Cement : 3 Fine Sand : 6 Graded stone aggregate of M3 1.00 4,498.43 4,498.43
40mm)
673 viii)1:4:8(1 Cement :4 Coarse Sand : 8 Graded stone aggregate of M3 1.00 4,434.56 4,434.56
40mm)
ESTIMATE
SUB: Rate Contract for Carrying Out Repair & Maintenance Work of Tanks and Pipelines at Operating Locations (Terminals, Depots) under Uttar Pradesh State
Office-I.
Ref. No.: UPSO-I/ENG/ M&I/Rate Contract Date 13.3.2018

Sr. No. Discription of work Unit Qty. Rate Amount


674 ix)1:4:8(1 Cement :4 Fine Sand : 8 Graded stone aggregate of 40mm) M3 1.00 4,165.30 4,165.30

675 x) 1:5:10(1 Cement :5 Coarse Sand : 10 Graded stone aggregate of M3 1.00 4,168.07 4,168.07
40mm)
676 xi)1:5:10(1 Cement :5 Fine Sand : 10 Graded stone aggregate of M3 1.00 3,921.15 3,921.15
40mm)
677 Providing & laying cement concrete in retaining walls, return walls, -
walls (any thickness) including attached pilasters, columns, piers,
abutments,pillars,posts,struts, buttresses,string or lacing courses,
parapets,coping, bed blocks, anchor blocks, plain window sills,
fillets etc. UP TO FLOOR V LEVEL excluding the cost of centering,
shuttering and finishing :

678 i) PCC 1 Cement:1 Coarse Sand:2 Graded Stone Aggregate 20mm M3 1.00 8,290.05 8,290.05

679 ii) PCC 1 Cement:1½ Coarse Sand:3 Graded Stone Aggregate 20mm M3 1.00 6,922.35 6,922.35

680 iii) PCC 1 Cement:2 Coarse Sand:4 Graded Stone Aggregate 20mm M3 1.00 6,483.96 6,483.96

681 iv) PCC 1 Cement:2 Coarse Sand:4 Graded Stone Aggregate 40mm M3 1.00 7,019.00 7,019.00

682 v) PCC 1 Cement:3 Coarse Sand:6 Graded Stone Aggregate 20mm M3 1.00 5,934.41 5,934.41

683 vi) PCC 1 Cement:3 Coarse Sand:6 Graded Stone Aggregate 40mm M3 1.00 5,601.14 5,601.14

684 vii)PCC 1 Cement:3 Fine Sand:6 Graded Stone Aggregate 40mm M3 1.00 5,556.18 5,556.18

685 Centering and shuttering including strutting, propping etc. and -


removal of form work for PCC
686 i) C&S for PCC in foundations,footings,bases of column M2 1.00 192.06 192.06
687 ii)C&S for PCC in retaining/return wall,wall including attached M2 1.00 374.91 374.91
pilaster buttresses, plinth & string courses,fillets etc.

688 iii) C&S for PCC in Columns, piers, abutment, pillars,posts & struts M2 1.00 463.3 463.30

689 Providing and fixing up to floor five level PRECAST CEMENT -


CONCRETE string or lacing courses, copings, bed plates, anchor
blocks, plain window sills, shelves, louvers, steps, stair cases, etc.
including hoisting and setting in position with cement mortar 1:3
(1 Cement : 3 coarse sand), cost of required centering complete
nominal size)
690 i)1:2:4( 1 Cement:2 Coarse sand:4 graded stone aggregate 20mm M3 1.00 6,266.35 6,266.35
nominal size)
691 ii)1:3:6( 1 Cement:3 Coarse sand:6 graded stone aggregate 20mm M3 1.00 5,722.54 5,722.54
nominal size)
692 iii)1:1.5:3( 1 Cement :1.5 Coarse sand: 3 graded stone aggregate M3 1.00 6,706.52 6,706.52
20mm nominal size)
693 Providing & fixing at or near ground level PRECAST CEMENT M3 1.00 6,109.79 6,109.79
CONCRETE in kerbs, edgings etc. as per approved pattern and setting
in position with cement mortar 1:3 (1 Cement : 3 coarse sand)
including the cost of required centering, shuttering complete

694 Providing and laying in position ready mixed plain cement -


concrete, with cement content as per approved design mix and
manufactured in fully automatic batching plant and transported to
site of work in transit mixer for all leads, having continuous
agitated mixer, manufactured as per mix design of specified grade
for plain cement concrete work, including pumping of R.M.C. from
transit mixer to site of laying & curing, excluding the cost of
centering, shuttering finishing including cost of curing, admixtures
in recommended proportions as per IS :9103 to accelerate/ retard
setting of concrete, improve workability without impairing
strength and durability as per direction of site engineer, ALL
WORKS UPTO PLINTH LEVEL.

695 i) M-15 grade plain cement concrete (cement content considered @ M3 1.00 6,130.43 6,130.43
240 kg/cum
696 ii) M-10 grade plain cement concrete (cement content considered @ M3 1.00 5,992.79 5,992.79
220 kg/cum)
697 Providing and laying in position ready mixed plain cement -
concrete, with cement content as per approved design mix and
manufactured in fully automatic batching plant and transported to
site of work in transit mixer for all leads, having continuous
agitated mixer, manufactured as per mix design of specified grade
for plain cement concrete work, including pumping of R.M.C. from
transit mixer to site of laying & curing, excluding the cost of
centering, shuttering finishing including cost of curing, admixtures
in recommended proportions as per IS :9103 to accelerate/ retard
setting of concrete, improve workability without impairing
strength and durability as per direction of site engineer, ALL
ABOVE PLINTH & UPTO FLOOR V LEVEL
ESTIMATE
SUB: Rate Contract for Carrying Out Repair & Maintenance Work of Tanks and Pipelines at Operating Locations (Terminals, Depots) under Uttar Pradesh State
Office-I.
Ref. No.: UPSO-I/ENG/ M&I/Rate Contract Date 13.3.2018

Sr. No. Discription of work Unit Qty. Rate Amount


698 i) M-15 grade plain cement concrete. (cement content considered @ M3 1.00 6,696.12 6,696.12
240 kg. /cum)
699 ii) M-10 grade plain cement concrete (cement content considered @ M3 1.00 6,558.53 6,558.53
220 kg/cum)
700 Providing and laying damp-proof course 40mm thick with cement M2 1.00 399.03 399.03
concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate 12.5mm nominal size). Item includes mixing water
proofing material in cement concrete work @ 1 kg per 50kg of
cement. Applying a coat of residual petroleum bitumen of grade VG-
10 of approved quality using 1.7kg per square metre on damp proof
course after cleaning the surface with brushes & finally with a piece
of cloth lightly soaked in kerosene oil.

701 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 M2 1.00 445.97 445.97
cement :3 coarse sand : 6graded stone aggregate 20mm nominal
size) over 75mm bed by dry brick ballast 40mm nominal size well
rammed and consolidated and grouted with fine sand including
finishing the top smooth
702 Providing and laying in position specified grade of reinforced
concrete excluding the cost of centering, shuttering, finishing
and reinforcement - All work up to plinth level

703 i) RCC 1 Cement :1 Coarse Sand: 2 Graded Stone Aggregate 20mm M3 1.00 7,707.88 7,707.88

704 ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm M3 1.00 6,154.84 6,154.84

705 iii) RCC 1 Cement :2 Coarse Sand: 4 Graded Stone Aggregate 20mm M3 1.00 5,716.45 5,716.45

706 Providing & Laying Reinforced cement concrete work in walls


(Any thickness) including attached pilasters, buttresses, plinth and
string courses, fillets,columns, pillars,piers, abutments, posts and
struts etc.UP TO FLOOR V LVL excluding cost of
centering,shuttering, finishing and reinforcement :

707 i) RCC 1 Cement :1 Coarse Sand: 2 Graded Stone Aggregate 20mm M3 1.00 8,432.26 8,432.26

708 ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm M3 1.00 7,076.24 7,076.24

709 iii) RCC 1 Cement :2 Coarse Sand: 4 Graded Stone Aggregate 20mm M3 1.00 6,597.49 6,597.49

710 Reinforced cement concrete work in beams, suspended floors, roofs M3 1.00 7,318.85 7,318.85
having slope up to 15° landings, balconies, shelves chajjas,
lintels, bands, plain window sills, staircases and spiral stair cases up
to floor five level excluding the cost of centering, shuttering,
finishing and reinforcement with 1:2:4 (1 cement : 2 coarse sand : 4
graded stone aggregate 20 mm nominal size).

711 Providing and laying up to floor five level reinforced cement M3 1.00 6,860.41 6,860.41
concrete in kerbs, steps and the like excluding the cost of
centering, shuttering, finishing and reinforcement with 1:2:4 (1
cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal
size).
712 Providing and laying RCC work in vertical and horizontal fins M3 1.00 6,650.92 6,650.92
individually or forming box louvers, facias and eaves boards up to
floor five level excluding the cost of centering, shuttering,
finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand
: 3 graded stone aggregate 20mm nominal size).

713 Centering and shuttering including strutting, propping etc. and


removal of form for :
714 i) Foundations,footings,bases of columns, etc. for mass concrete M2 1.00 192.06 192.06

715 ii)Walls (any thickness) including attached pilasters, buttress, plinth M2 1.00 374.91 374.91
and string courses etc.
716 iii) Suspended floors,roofs,landings,balconies, access platform and M2 1.00 418.19 418.19
Shelves (Cast in situ)
717 iv) Lintels, beams plinth beams,girders bressumers and cantilevers M2 1.00 339.56 339.56

718 v) Columns, Pillars, Piers, Abutments, Posts and Struts. M2 1.00 463.3 463.30
719 vi) Stairs, (excluding landings) except spiral-staircases M2 1.00 415.27 415.27
720 vii)Vertical and horizontal fins individually or forming box, louver M2 1.00 621.74 621.74
bands facias and eaves boards.
721 vii) Suspended floors, roofs,landings balconies and access platform M2 1.00 492.61 492.61
with water proof ply 12mm thick.
722 vii)Lintels, beams, plinth beams, girders, bressumers , columns, M2 1.00 414.87 414.87
cantilevers. with water proof ply 12mm thick.
723 Providing, hoisting and fixing up to floor five level precast M3 1.00 12,602.66 12,602.66
reinforced cement concrete in shelves including setting in cement
mortar 1:3 (1 cement : 3 coarse sand), cost of required centering,
shuttering and finishing with neat cement punning on exposed
surfaces but excluding the cost of reinforcement with 1:2:4 (1
cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal
size).
ESTIMATE
SUB: Rate Contract for Carrying Out Repair & Maintenance Work of Tanks and Pipelines at Operating Locations (Terminals, Depots) under Uttar Pradesh State
Office-I.
Ref. No.: UPSO-I/ENG/ M&I/Rate Contract Date 13.3.2018

Sr. No. Discription of work Unit Qty. Rate Amount


724 Supply of Reinforcement for R.C.C. including straightening, cutting,
bending, placing in position & binding all complete at all levels

725 i) Mild steel,medium tensile steel bars etc. conforming to IS 432-I&II KG 1.00 54.76 54.76

726 ii)Thermo Mechanically Treated Bars Fe- 500 grade,Conforming to KG 1.00 56.05 56.05
IS1786
727 Providing and laying in position, machine batched, machine mixed
design mix M-25 grade cement concrete for reinforced cement
concrete work, using cement as per approved design mix, including
pumping of concrete to site of laying but excluding the cost of
centering, shuttering, finishing and reinforcement. including
Admixtures in recommended proportions as per IS 9103 to
accelerate, retard setting of concrete,improve workability without
impairing strength and durability as per direction of Engineer-in-
charge. (Note :- Cement content considered in this item is @ 330
kg/cum. Excess/less cement used as per design mix is
payable/recoverable separately).

728 i) M-25 grade reinforced cement concrete UP TO PLINTH LEVEL M3 1.00 6,383.69 6,383.69

729 ii) M-25 grade reinforced cement concrete ABOVE PLINTH & UP TO M3 1.00 7,179.47 7,179.47
FLOOR 5 LEVEL
730 Providing and laying in position ready mixed concrete of
M25 grade, manufactured in fully automatic batching plant and
transported to site of work in transit mixer for all leads having
continuous agitated mixer, manufactured as per mix design of
specified grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying , excluding
the cost of centering, shuttering finishing and reinforcement
including cost of admixtures in recommended proportions as per IS
: 9103 to accelerate/ retard setting of concrete, improve
workability without impairing strength and durability as per
direction of the Engineer - in - charge. (Note :- Cement content
considered in this item is @ 330 kg/cum. Excess/less cement used
as per design mix is payable/recoverable separately).

731 i) M25 RMC for All works UP TO PLINTH LEVEL M3 1.00 6,648.24 6,648.24
732 ii) M25 RMC for All works ABOVE PLINTH UPTO FLOOR 5 LEVEL M3 1.00 7,444.02 7,444.02

733 Extra for providing richer mixes at all floor levels. Note:-
Excess/less cement over the specified cement content used is
payable /recoverable separately.
734 i)Providing M-30 grade concrete instead of M-25 grade BMC/RMC. M3 1.00 68.82 68.82
(Note:- Cement content considered in M-30 is @ 340 kg/cum).

735 ii) Providing M-35 grade concrete instead of M-25 grade BMC/RMC. M3 1.00 137.6 137.60
(Note : Cement content considered in M-35 is @ 350 kg/cum).

736 iii) Providing M-40 grade concrete instead of M-25 grade M3 1.00 206.42 206.42
BMC/RMC.(Note : Cement content considered in M-40 is @ 360
kg/cum).
737 Deduct for using less cement than the quantity as provided in the KG 1.00 666.2 666.20
item of BMC/RMC as arrived as per mix design.
738 Extra for R.C.C./ B.M.C/ R.M.C. work above floor V level for each M3 1.00 230.04 230.04
four floors or part thereof.
739 Providing and laying Brick work with bricks of class designation 75
Including Scaffolding :
740 Brick work in Cement mortar 1:4 (1 cement : 4 coarse sand) IN M3 1.00 4,921.91 4,921.91
FOUNDATION AND PLINTH
741 Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN M3 1.00 4,705.39 4,705.39
FOUNDATION AND PLINTH
742 Brick work in Cement mortar 1:4 (1 cement: 4 coarse sand) in M3 1.00 5,745.02 5,745.02
superstructure ABVOE PLINTH & UP TO FLOOR V LEVEL
743 Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand) in M3 1.00 5,528.50 5,528.50
superstructure ABVOE PLINTH & UP TO FLOOR V LEVEL
744 Extra for brick work in superstructure above floor V level for each M3 1.00 203.45 203.45
four floors or part thereof by mechanical means by lifting material
using mobile crane
745 7Cm Thick Brick work in cement mortar 1:3(1 cement:3 coarse sand) M2 1.00 530.29 530.29
in superstructure
746 Half brick masonry in Cement mortar 1:3 (1 cement : 3 coarse sand) M2 1.00 611.98 611.98
IN FOUNDATION AND PLINTH
747 Half brick masonry in Cement mortar 1:4 (1 cement : 4 coarse sand) M2 1.00 587.72 587.72
IN FOUNDATION AND PLINTH
748 Half brick masonry in Cement mortar 1:3 (1 cement : 3 coarse sand) M2 1.00 701.8 701.80
IN superstructure ABOVE PLINTH & UP TO FLOOR V LEVEL

749 Half brick masonry in Cement mortar 1:4 (1 cement : 4 coarse sand) M2 1.00 677.54 677.54
superstructure ABOVE PLINTH & UP TO FLOOR V LEVEL
ESTIMATE
SUB: Rate Contract for Carrying Out Repair & Maintenance Work of Tanks and Pipelines at Operating Locations (Terminals, Depots) under Uttar Pradesh State
Office-I.
Ref. No.: UPSO-I/ENG/ M&I/Rate Contract Date 13.3.2018

Sr. No. Discription of work Unit Qty. Rate Amount


750 Extra for half brick masonry in superstructure, above floor V level M2 1.00 18.02 18.02
for every four floors or part thereof by mechanical means by lifting
material using mobile crane.
751 Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars M2 1.00 56.3 56.30
at every third course of half brick masonry.
752 Brick work with Class Designation 50 bricks in Cement mortar 1:4 (1 M3 1.00 4,637.67 4,637.67
cement : 4 coarse sand) IN FOUNDATION AND PLINTH

753 Brick work with Class Designation 50 bricks in Cement mortar 1:4 (1 M3 1.00 4,982.47 4,982.47
cement : 4 coarse sand) in superstructure ABOVE PLINTH AND UP
TO FLOOR V LEVEL
754 Half brick masonry with Class designation 50 bricks in Cement M2 1.00 555.24 555.24
mortar 1:4 (1 cement : 4 coarse sand) IN FOUNDATION AND PLINTH

755 Half brick masonry with Class designation 50 bricks in Cement M2 1.00 645.02 645.02
mortar 1:4 ( 1 cement : 4 coarse sand) IN superstructure ABOVE
PLINTH & UP TO FLOOR V LEVEL
756 Providing and laying Brick edging 7cm wide 11.4cm. deep to plinth M 1.00 38.82 38.82
protection with bricks of class designation 75 including grouting with
cement mortar 1:4 (1 cement : 4 fine sand)

757 Providing and laying brick on edge flooring with bricks of Class
designation 75 on a bed of 12mm cement mortar including filing
the joints with same mortar with common burnt clay brick in

758 i) cement mortar 1:4 (1 cement : 4 fine sand) M2 1.00 669.37 669.37
759 ii) cement mortar 1:6 (1 cement : 6 fine sand) M2 1.00 631.79 631.79
760 Providing and laying Dry brick on edge flooring in required pattern M2 1.00 510.98 510.98
with bricks of Class designation 75 on a bed of 12mm mud mortar
including filling joints with fine sand complete.

761 Structural steel work in single section fixed with or without KG 1.00 57.88 57.88
connecting plate including cutting, hoisting, fixing in position and
applying a priming coat of approved steel primer all complete.

762 Structural steel work riveted,bolted or welded in built up sections, KG 1.00 66.94 66.94
trusses & framed work, including cutting, hoisting, fixing in position
and applying a priming coat of approved steel primer all complete:

763 Steel work in built up tubular trusses including cutting,hoisting


fixing in position & applying a priming coat of approved steel
primer, welded and bolted including special shaped washers etc.
complete.
764 i) Hot finished welded type tubes. KG 1.00 89.37 89.37
765 ii) Hot finished seamless type tubes. KG 1.00 92.99 92.99
766 Providing & fixing hand rail of approved size, welding etc. to steel
ladder railing,balcony railing & staircase railing including applying
priming coat of approved steel primer.
767 i) M.S. tube. KG 1.00 91.1 91.10
768 ii) E.R.W. tubes. KG 1.00 116.9 116.90
769 iii) G.I. pipes KG 1.00 99.27 99.27
770 40mm Thick Cement concrete flooring 1:2:4 (1 cement : 2 coarse M2 1.00 359.07 359.07
sand:4 stone aggregate of 20mm nominal size) finished with a
floating cement coat of neat including cement slurry, but excluding
the cost of nosing of steps etc. complete.

771 52 mm thick cement concrete flooring with concrete hardener M2 1.00 549.84 549.84
topping under layer 40 mm thick cement concrete 1:2:4 (1 cement :
2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and
top layer 12 mm thick cement hardener consisting of mix 1:2 (1
cement hardener mix : 2 graded stone aggregate 6 mm nominal
size) by volume, hardening compound is mixed @ 2 litre per 50kg
of cement or as per manufacturers specifications. This includes cost
of cement slurry, 2mm thick PVC strip at desired spacing, cost of
nosing in steps Complete.

772 18mm thick Cement plaster skirting with cement mortar 1:3 (1 M2 1.00 346.64 346.64
cement : 3 coarse sand) finished with floating coat of neat cement.

773 Precast terrazzo tiles 22mm thick with graded marble chips of size M2 1.00 943.08 943.08
upt 12mm laid in floors, landings, jointed with neat cement slurry
mixed with pigment to match the shade of the tiles including
rubbing & wax polishing complete precast tiles on 20mm thick bed
of cement mortar 1:4, (1cement :4 coarse sand) : LIGHT SHADE
USING WHITE CEMENT

774 Precast terrazzo tiles 22mm thick with graded marble chips of sizes M2 1.00 1,268.03 1,268.03
up to 12mm in skirting & risers of steps not exceeding 30 cm in
height on 12mm thick cement plaster 1:3 (1 cement :3 coarse sand)
jointed with neat cement slurry mixed with pigment to match the
shade of the TILES, including rubbing, wax polishing complete with
tiles of LIGHT SHADE USING WHITE CEMENT
ESTIMATE
SUB: Rate Contract for Carrying Out Repair & Maintenance Work of Tanks and Pipelines at Operating Locations (Terminals, Depots) under Uttar Pradesh State
Office-I.
Ref. No.: UPSO-I/ENG/ M&I/Rate Contract Date 13.3.2018

Sr. No. Discription of work Unit Qty. Rate Amount


775 Chequered precast cement concrete tiles 22 mm thick in footpath & M2 1.00 709.38 709.38
courtyard jointed with neat cement slurry mixed with pigment to
match the shade of tiles including rubbing and cleaning etc.
complete on 20 mm thick bed of cement mortar 1:4 (1 cement: 4
coarse sand). TILES OF DARK SHADE USING ORDINARY CEMENT

776 Providing & fixing Ist quality ceramic glazed wall tiles conforming to M2 1.00 737.55 737.55
IS : 15622 (thickness as specified by the manufacturer ) of approved
make in all colours,shades except burgundy,bottle green,black of
any size as approved by Engineer-in-Charge in skirting,risers of steps
and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3
coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm
including pointing in white cement mixed with pigment of
matching shade.

777 Providing & laying rectified Glazed Ceramic floor tiles 300x300 mm M2 1.00 681.65 681.65
or more (thickness to be specified by the manufacturer) of 1st
quality conforming to IS : 15622 of approved make in colours White,
Ivory, Grey, Fume Red Brown, laid on 20mm thick cement mortar
1:4 (1 Cement : 4 Coarse sand) including grouting the joints with
white cement and matching pigments etc., complete.

778 Providing & laying vitrified floor tile in different sizes (thickness as
per manufacturer) with water absorption's less than 0.08% and
conforming to IS : 15622 of approved make in all colours and
shades, laid on 20mm thick cement mortar as specified with
coarse sand, including grouting the joints with white cement and
matching pigments etc., complete for flooring/skirting as specified.

779 i) Flooring with size of Tiles 60x60Cm in cement mortar 1:4 M2 1.00 1,108.50 1,108.50
780 ii) Flooring with size of Tiles 80x80Cm in cement mortar 1:4 M2 1.00 1,401.18 1,401.18
781 iii) Skirting with size of Tiles 60x60Cm in Cement mortar 1:3 M2 1.00 1,124.15 1,124.15
782 iv) Skirting with size of Tiles 80x80Cm in cement mortar 1:3 M2 1.00 1,418.85 1,418.85
783 Deduct for not using 20mm thick cement mortar 1:4 (1 cement : 4 M2 1.00 461.91 461.91
coarse sand) bedding in laying of floor tiles.
784 Fixing glazed/ Ceramic/Vitrified floor tiles with cement based high M2 1.00 382.44 382.44
polymer modified quick-set tile adhesive (Water based) conforming
to IS: 15477 , using quick set tile adhesive(water based) in average
3mm thickness.
785 Providing & fixing Klippon Galvalume steel profile sheets (size,
shape and pitch of corrugation as approved by Engineer-in-charge)
of bare metal thickness 0.50mm as per ASTM A446 having yield
stress of 275mpa, surface shall have hot dip metallic coating of
Aluminium Zinc alloy comprising of 55% aluminium,43.5% zinc &
1.5% silicon, with 5-7 micron epoxy primer and polyester top coat
of 15-18 micron on both sides,total coated thickness(TCT) of
0.58mm.Sheet shall have protective guard film of 25 microns
minimum to avoid scratches while transportation & should be
supplied in single length up to 6m or as desired by Engineer-in-
charge.

786 i) Profile Sheet for roofing M2 1.00 1,382.15 1,382.15


787 ii) Plain Sheet for Ridges (500 - 600mm). M2 1.00 356.94 356.94
788 iii) Plain sheet for Flashings/ Aprons.( Upto 600 mm) M2 1.00 329.56 329.56
789 iv) Plain Sheet for Gutter .(600 mm over all girth). M2 1.00 824.94 824.94
790 Providing and fixing on wall face unplasticised Rigid PVC rain water
pipes conforming to IS:13592 Type A including jointing with seal
ring conforming to IS : 5382 leaving 10 mm gap for thermal
expansion, Single socketed pipes.
791 i) 75 mm diameter M 1.00 147.3 147.30
792 ii) 110 mm diameter M 1.00 234.05 234.05
793 iii) 160 mm diameter PVC Rain water pipe M 1.00 499.64 499.64
794 Providing & fixing on wall face unplasticised - PVC moulded
fittings/ accessories for unplasticised Rigid PVC rain water pipes
conforming to IS : 13592 Type A including jointing with seal ring
conforming to IS : 5382 leaving 10 mm gap for thermal expansion.

795 i) 75mm Coupler EA 1.00 64.32 64.32


796 ii) 110mm Coupler EA 1.00 101.65 101.65
797 iii) 75 mm Single pushfit Coupler EA 1.00 64.32 64.32
798 iv) 110 mm Single pushfit Coupler EA 1.00 93.63 93.63
799 v) Single tee with door of 75x75x75 mm EA 1.00 120.32 120.32
800 vi) Single tee with door of 110x110x110 mm EA 1.00 179.78 179.78
801 vii) Single tee without door of 75x75x75 mm EA 1.00 104.23 104.23
802 viii) Single tee without door of110x110x110 mm EA 1.00 165.97 165.97
803 ix) 87.5° Bend of 75 mm EA 1.00 75.8 75.80
804 x) 87.5° Bend of 110 mm EA 1.00 112 112.00
805 xi) Shoe (Plain) of 75 mm EA 1.00 65.46 65.46
806 xii) Shoe (Plain) of 110 mm EA 1.00 97.05 97.05
807 Providing and laying cement plaster on surfaces with fine sand
including curing etc.
808 i) 12 mm cement plaster of mix1:4(1 cement: 4 fine sand) M2 1.00 171.27 171.27
809 ii)12 mm cement plaster of mix1:6 1 cement: 6 fine sand) M2 1.00 158.79 158.79
ESTIMATE
SUB: Rate Contract for Carrying Out Repair & Maintenance Work of Tanks and Pipelines at Operating Locations (Terminals, Depots) under Uttar Pradesh State
Office-I.
Ref. No.: UPSO-I/ENG/ M&I/Rate Contract Date 13.3.2018

Sr. No. Discription of work Unit Qty. Rate Amount


810 iii) 15mm Cement plaster of mix1:4 (1cement: 4 fine sand) on rough M2 1.00 198.3 198.30
side of half or single brick wall
811 iv) 15mm Cement plaster of mix1:6 (1 cement: 6 fine sand) on rough M2 1.00 183.4 183.40
side of half or single brick wall
812 v) 20mm Cement plaster of mix1:4 (1 cement: 4 fine sand) M2 1.00 237.81 237.81
813 vi) 20mm Cement plaster of mix1:6 (1 cement: 6 fine sand) M2 1.00 218.45 218.45
814 Providing Neat cement punning M2 1.00 42.19 42.19
815 Distempering with 1st quality acrylic washable distemper (ready M2 1.00 52.63 52.63
mixed)of approved manufacturer& of required shade and colour
complete as per manufacturer's specification with 2 or more coats

816 Applying one coat of cement primer of approved brand and M2 1.00 36.59 36.59
manufacture on wall surface :
817 Finishing walls with water proofing cement paint of required shade M2 1.00 58.23 58.23
with Two or more coats applied @ 3.84 kg/10 sqm

818 Finishing walls with textured exterior paint of required shade with M2 1.00 149.18 149.18
Two or more coats applied @ 3.28 ltr/10 sqm, over and including
base coat of water proofing cement paint applied @ 2.20kg/10 sqm.

819 Finishing walls with Acrylic Smooth exterior paint of required shade M2 1.00 95.11 95.11
with Two or more coat applied @ 1.67 ltr/10 sqm over & including
base coat of water proofing cement paint applied @ 2.20kg/10 sqm.

820 Finishing walls with Deluxe Multi surface paint system for interiors M2 1.00 97.99 97.99
&exteriors using Primer as per manufacturers specifications with
two or more coats applied @ 1.25 ltr/10 sqm. over and including
one coat of Special primer applied @ 0.75 ltr / 10sqm

821 Painting Steel work with Deluxe Multi Surface Paint to give an even M2 1.00 87.74 87.74
shade. Two or more coat applied @0.90 ltr/10 sqm over an under
coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand or
manufacture
822 Demolishing cement concrete manually/ by mechanical
means including disposal of material outside premises at
unobjectionable and as per direction of Engineer - in - charge.

823 i) 1:3:6 or richer mix M3 1.00 987.34 987.34


824 ii) 1:4:8 or leaner mix M3 1.00 609.16 609.16
825 Demolishing R.C.C. work manually/ by mechanical means including M3 1.00 1,440.39 1,440.39
stacking of steel bars & disposal of unserviceable material outside
site at unobjectionable place& as per direction of Engineer-in-
charge.
826 Extra for cutting reinforcement bars manually/ by mechanical means M2 1.00 495.92 495.92
in R.C.C. or R.B. work (Payment shall be made on the cross sectional
area of R.C.C. or R.B. work) as per direction of Engineer-in-charge.

827 Demolishing brick work manually/mechanical means including M3 1.00 834.55 834.55
stacking of serviceable material & disposal of unserviceable material
outside site at unobjectionable place & as/direction of Engineer-in-
charge.
828 Demolishing stone masonry manually/ by mechanical means M3 1.00 995.91 995.91
including stacking serviceable material & disposal of unserviceable
material out of site at unobjectionable place and as per direction of
Engineer-in-charge:
829 Supply & filling coarse sand of Zone III in SAND PAD foundation in M3 1.00 2,238.77 2,238.77
layers not exceeding 200mm.Each deposited layer shall be
compacted by mechanical vibration and watering to achieve
minimum relative density 85 %. Last layer of sand pad to be
prepared in desired slope.
830 Preparation and consolidation of sub grade with power road roller M2 1.00 89.22 89.22
of 8 to 12 tonne capacity after excavating earth to an average of
22.5 cm. depth dressing to camber and consolidating with road
roller including making good the undulations etc. and re-rolling the
sub grade and disposal of surplus earth within premises
ESTIMATE
SUB: Rate Contract for Carrying Out Repair & Maintenance Work of Tanks and Pipelines at Operating Locations (Terminals, Depots) under Uttar Pradesh State
Office-I.
Ref. No.: UPSO-I/ENG/ M&I/Rate Contract Date 13.3.2018

Sr. No. Discription of work Unit Qty. Rate Amount


831 Providing & laying 80mm thick factory made Pre-cast cement M2 1.00 1099.00 1,099.00
concrete interlocking paver block of M 40 grade made by block
making machine with strong vibratory compaction & of approved
size and design/ shape shade and manufacturers and as per IOCL's
specifications. The paver block will have peripheral chamfer,with
average crushing strength more than 40 N/Sq.mm as/ BS6717 Part -
1(1986), maximum water absorption of 2% after 10 minutes and 5%
after 24 hrs. as per BS 1881, maximum dimensional deviations of +/-
2mm on length & width and +/- 3mm on on thickness. The job
includes supplying & laying a layer of 50mm thick clean course sand
on thoroughly compacted sub-base below the paver blocks, cutting
the paver blocks wherever required with hydraulic splitter, filling in
the joints at the edges of paver blocks with sand,compacting with
machine vibrator to required line and level, etc. complete.(Payment
for provision of edge restraints shall be made separately);- Grey or
Coloured 80mm thick paver blocks

832 Taking out existing CC interlocking paver blocks from footpath M2 1.00 53.42 53.42
central verge, including removal of rubbish etc., disposal of
unserviceable material out of site at unobjectionable place &
stacking serviceable material within 50 metre lead as per direction of
Engineer - in-Charge

833 Laying Corporation supplied interlocking paver blocks of any design M2 1.00 207.16 207.16
/shape laid in required line,level,curvature,colour & pattern over
and including 50mm thick compacted bed of coarse sand, filling the
joints with fine sand etc. all complete as/ direction of Engineer-in-
charge.

834 Providing and fixing concertina coil fencing with punched tape M 1.00 252.52 252.52
concertina coil 600mm dia 10metre openable length(total length
90m) having 50 nos. rounds per 6 metre length, upto 3 m height of
wall with existing angle iron 'Y' shaped placed 2.4 m or 3.00 m apart
and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with
G.I. staples and G.I. clips to retain horizontal including necessary
bolts or G.I. barbed wire tied to angle iron all complete as per
direction of Engineer-in-charge with reinforced barbed tape (RBT)/
Spring core(2.5mm thick)wire of high tensile strength of 165
kg/sq.mm with tape (0.52 mm thick) and weight 43.478gm/metre.
(cost of M.S. angle, C.C.blocks shall be paid separately)

835 Providing and laying non-pressure NP2 class (light duty) R.C.C.
pipes with collars jointed with stiff mixture of cement mortar in
the proportion of 1:2 (1 cement : 2 fine sand) including testing of
joints etc. complete : Light Duty
836 i) 100 mm dia. R.C.C. pipe M 1.00 322.38 322.38
837 ii) 150 mm dia. R.C.C. pipe M 1.00 353.23 353.23
838 iii) 250 mm dia. R.C.C. pipe M 1.00 477.36 477.36
839 iv) 300 mm dia. R.C.C. pipe M 1.00 513.5 513.50
840 v) 600 mm dia. R.C.C. pipe M 1.00 1,383.50 1,383.50
841 vi) 900 mm dia. R.C.C. pipe M 1.00 1,969.59 1,969.59
842 vii) 1000 mm dia. R.C.C. pipe M 1.00 2,441.50 2,441.50
843 Providing and laying non-pressure NP3 class R.C.C. pipes with
collars jointed with stiff mixture of cement mortar in the
proportion of 1:2 (1 cement : 2 fine sand) including testing of joints
etc.complete: Medium Duty, Laying Mechanically/manual

844 i) 600 mm dia. R.C.C. pipe M 1.00 2,493.34 2,493.34


845 ii) 900 mm dia. R.C.C. pipe M 1.00 3,925.86 3,925.86
846 iii) 1200 mm dia. R.C.C. pipe M 1.00 6,394.98 6,394.98
847 Constructing brick masonry manhole in cement mortar 1:4 ( 1
cement : 4 coarse sand ) R.C.C. top slab with 1:2:4 mix (1 cement :
2 coarse sand : 4 graded stone aggregate 20 mm nominal size),
foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8
graded stone aggregate 40mm nominal size) inside plastering
12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand)
finished with floating coat of neat cement and making channels in
cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate 20mm nominal size) finished with a floating coat of neat
cement complete as per standard design :

848 i) Inside size 90x80 cm and 45 cm deep including C.I. cover with EA 1.00 8,550.05 8,550.05
frame (light duty) 455x610 mm internal dimensions total weight of
cover and frame to be not less than 38 kg (weight of cover 23 kg and
weight of frame 15 kg) : with Common burnt clay bricks of class
designation 75
ESTIMATE
SUB: Rate Contract for Carrying Out Repair & Maintenance Work of Tanks and Pipelines at Operating Locations (Terminals, Depots) under Uttar Pradesh State
Office-I.
Ref. No.: UPSO-I/ENG/ M&I/Rate Contract Date 13.3.2018

Sr. No. Discription of work Unit Qty. Rate Amount


849 Supplying and providing crushed stone ring of trapezoidal cross M3 1.00 1678.10 1,678.10
section on the sand pad foundation by using 80 mm & down size
well graded hard granite metal including packing the stone ring with
sand by copiously watering in layers in not more than 300 mm per
layer and as per enclosed specifications.

850 Providing and laying 40 mm and down size hard granite metal layer M3 1.00 2125.38 2,125.38
of 300 mm horizontal thickness as per specs.(Filter 1).

851 Providing and laying 12 mm and down size stone chips layer of 300 M3 1.00 2180.90 2,180.90
mm horizontal thickness as per detailed specs (Filter 2).

852 Supplying and laying black LDPE film, (1000 MICRON/1MM thick ) as M2 1.00 240.00 240.00
per IS 2508- 1984; joints in the film shall be heat sealed in situ
during laying of the film using a 3 sealer iron and checked carefully.
The material shall be bought from M/s. IPCL/ approved
manufacturers.
Anchoring the LDPE film at the periphery of the tank pad as per
detailes including earthwork, brickwork in CM 1:5 below ground
level using best quality chamber burnt bricks etc.& as per site
instructions.
Note: The LDPE film shall be measured for the area laid as per
drawing requirements. No extra payment for the overlaps, wastages
shall be made.
853 Supplying and laying PVC drain pipe (PVC Schedule 40 with wall M 1.00 112.08 112.08
thickness of 3.38 mm ) of 25 mm dia perforatedunder the tank area
as per guideline given in API 650 (App. I); The outer end of pipe shall
project 150 mm beyond the sand pad & covered with a nylon mesh.

854 Supplying & providing Murram padding for 150 mm thk. for the M3 1.00 755.25 755.25
apron and slope of the sand pad including consolidating by
watering, ramming to required shape as per drawing and
instructions.
855 Supplying & providing brick pitching (brick flat soling) using good M2 1.00 587.65 587.65
quality chamber burnt bricks (minimum 50 KSC compressive
strength) laid flat (75 mm thk) to required slope and shape and
pointing the joints in CM 1:3 for the sand pad apron and slope.

856 Supplying and laying bituminous carpet (anti corrosive layer) of 75 M2 1.00 397.00 397.00
mm thk. for sand pad in two layers using bitumen and stone grit mix
made by thoroughly mixing dry stone grit with hot asphalt grade
VG10 8 to 10 % by volume and consolidating and rolling lightly to
conform to the tank bottom slope etc.

857 Providing and laying 40 mm thk. CC 1:2:4 for apron and slope of M2 1.00 207.41 207.41
sand pad using 12- 20 mm thk. hard granite metal including
compaction, finishing to shape,curing etc. complete. Expansion
joints shall be provided at 4 m c/c on the apron and shall be filled
with polysulphide material as per manufacturer's specifications.

NOTE: Sub- Total "A") 9,363,029.22


1 Rates for item have been taken from SOR rates of Lucknow DO and M&I rate contract placed by Add GST @ 18% 1,685,345.26
WBSO (12015348) and PO No.25220093 of LKO Tl.
Sub Total "B" 11,048,374.47
Grand Total 11,048,374.47

You might also like