Carriageway Surfaces Section 1 -01 1 way 25mm duct m 2.398 Section 1 -02 1 way 50mm duct m 2.438 Section 1 -03 1 way 110 mm duct m 2.585 Section 1 -04 2 way 110 mm duct m 2.825 Section 1 -05 4 way 110 mm duct m 3.555 Section 1 -06 1 way 110 mm GI Pipe m 4.009 Section 1 -07 2 way 110 mm GI Pipe m 4.218 Footway Surfaces Section 1 -08 1 way 25mm duct m 1.747 Section 1 -09 1 way 50mm duct m 1.824 Section 1 -10 1 way 110 mm duct m 1.884 Section 1 -11 2 way 110 mm duct m 1.732 Section 1 -12 4 way 110 mm duct m 2.005 Section 1 -13 1 way 110 mm GI Pipe m 4.367 Section 1 -14 2 way 110 mm GI Pipe m 4.673 Unmade Surfaces Section 1 -15 1 way 25mm duct m 1.444 Section 1 -16 1 way 50mm duct m 1.656 Section 1 -17 1 way 110 mm duct m 1.656 Section 1 -18 2 way 110 mm duct m 1.354 Section 1 -19 4 way 110 mm duct m 1.571 Section 1 -20 1 way 110 mm GI Pipe m 4.061 Section 1 -21 2 way 110 mm GI Pipe m 4.035 Open Trench Section 1 -22 1 way 25mm duct m 0.070 Section 1 -23 1 way 50mm duct m 0.206 Section 1 -24 1 way 110 mm duct m 0.190 Section 1 -25 2 way 110 mm duct m 0.141 Section 1 -26 4 way 110 mm duct m 0.379 Section 1 -27 1 way 110 mm GI Pipe m 0.340 Section 1 -28 2 way 110 mm GI Pipe m 0.581 Section 2: Blockages Rectify duct blockage in Footway- Locate blockage, ea section 2 -01 excavate (all footway surfaces) repair duct backfill and reinstatement 12.677 Rectify duct blockage in Carriageway- Locate blockage, ea section 2 -02 excavate (all carriageway surfaces) repair duct backfill and reinstatement 14.692 ea section 2 -03 Locate buried chamber cover and raise to ground level 23.570 Section 3: Vibration Free Drilling Core through Chamber wall vibration free section 3 -01 1 x 110mm duct ea 7.062 section 3 -02 2 x 110mm duct ea 7.519 section 3 -03 1 x 50mm duct ea 7.018 Core through building wall vibration free ea - section 3 -04 1 x 110mm duct ea 5.153 section 3 -05 2 x 110mm duct ea 7.408 section 3 -06 1 x 50mm duct ea 3.995 Section 4: Misc. Civils Operations Supply and installation of Lean Mix Concrete for wadi and m3 section 4 -01 re-instatement works with a depth of 1m -2m 31.923 section 4 -02 Excess excavation up to 1m-2m depth m3 3.108 section 4 -03 Excess excavation up to 2m-5m depth m3 4.530 section 4 -04 Break Out Gabions (Flat) including netting and fixings m2 12.992 section 4 -05 Break Out Gabions (Wall) including netting and fixings m2 15.699 section 4 -06 Provide And Lay Conc. Quality 'C' For Protection m3 7.548 section 4 -07 Break Out Boulder Rock m3 10.549 Excavate Trial pit in normal soil between surface level & 1 m3 section 4 -08 m depth 3.552 Excavate Trial pit in normal soil between 1 m to 2m depth m3 section 4 -09 4.350 Excavate Trial pit in hard soil between surface level & 1 m m3 section 4 -10 depth 4.709 Excavate Trial pit in hard soil between 1 m to 2m depth m3 section 4 -11 5.413 Excavate Trial pit in rocky soil between surface level & 1 m m3 section 4 -12 depth 10.345 Excavate Trial pit in rocky soil between 1 m to 2m depth m3 section 4 -13 21.466 Installation/Fixing of 25 mm bend for use with wall capping ea section 4 -14 0.360 Installation/Fixing of 50 mm bend for use with wall capping section 4 -15 ea 0.468 Installation/Fixing of 110 mm bend for use with wall section 4 -16 ea capping 0.790 Section 6: Chamber Construction Carriageway Surfaces Section 6 -01 Precast Type 4 Chamberwith D400 lid(s) ea 54.076 Section 6 -02 Precast Type 6 Chamber -with D400 lid(s) ea 65.459 Footway and Unmade Surfaces Section 6 -03 Precast Type 4 Chamber- with D400 lid(s) ea 42.348 Section 6 -04 Precast Type 6 Chamber -with D400 lid(s) ea 57.578 Misc. Items Section 6 -05 Install Gas Seal (Caulking Gland) 110mm ea 0.271 Section 6 -06 Install Gas Seal (Caulking Gland) 50mm ea 0.232 Drill through chamber wall non-vibration free Section 6 -07 1 x 110mm duct ea 8.457 Section 6 -08 2 x 110mm duct ea 9.758 Drill through building wall non-vibration free Section 6 -09 1 x 110mm duct ea 3.865 Section 6 -10 2 x 110mm duct ea 4.786 Section 6 -11 1 x 50mm duct ea 4.006 Section 6 -12 1 x 25mm duct ea 1.719 Section 6 -13 Neck/Collar Raising of Type 4 Chamber up to 500mm ea 46.537 Section 6 -14 Neck/Collar Raising of Type 6 Chamber up to 500mm ea 58.486 ea Section 6 -15 Neck/Collar Raising of round shaft manhole up to 500mm 52.204 Demolish existing Chamber in all surfaces, Includes back fill ea Section 6 -16 & reinstatement 40.686 Section 7: FDH Construction section 7 -01 Install Precast FDH Base ea 33.944 section 7 -02 Fitting of Fibre Street Cabinet ea 32.479 FDH Protection Posts- supply & fit 1 x 90mm galvanised ea section 7 -03 iron pipes set in concrete protruding 1.5m above ground level 8.470 section 7 -04 Relocation/Dismantling of exisiting FDH cabinet ea 65.608 section 7 -05 Sealing of all cables in cabinet ea 3.400 section 7 -06 Install Name Plate for FDH cabinet ea 2.165 Section 8: External Cabling Cabling in external network Rod and Rope duct section Empty bore. Install nylon m Section 8 -01 draw rope in empty bore 0.092 Rod and Rope duct section Occupied bore.Install nylon m Section 8 -02 draw rope in occupied bore. 0.108 Section 8 -03 Install F.O. Cable < 20mm Diam Empty bore. m 0.097 Section 8 -04 Install F.O. Cable < 20mm Diam Occupied bore. m 0.151 Section 8 -05 Install F.O. Cable > 20mm Diam Empty bore. m 0.087 Section 8 -06 Install F.O. Cable >20mm Diam Occupied bore. m 0.164 Cabling on Wall Section 8 -07 Up to 30mm Cable on wall (Internal) m 0.193 Section 8 -08 Up to 30mm Cable on wall (External) m 0.216 Fit Galvanised Steel Trunking Section 8 -09 100mm x 100mm m 0.725 Section 8 -10 100mm x 50mm m 0.678 Section 8 -11 75mm x 75mm m 0.587 Section 8 -12 50mm x 50mm m 0.506 Fit PVC Trunking Section 8 -13 100mm x 100mm m 0.564 Section 8 -14 100mm x 50mm m 0.506 Section 8 -15 75mm x 75mm m 0.476 Section 8 -16 50mm x 50mm m 0.367 Section 8 -17 20mm x 10mm m 0.312 Fit PVC Spiral Flexible Conduit Section 8 -18 10mm m 0.162 Section 8 -19 25mm m 0.208 Fit Galvanised Steel tray Section 8 -20 50mm m 0.978 Section 8 -21 100mm m 0.619 Section 8 -22 150mm m 1.254 Section 8 -23 225mm m 1.437 Wall Mounted Equipment Section 8 -24 Fit CAP ea 3.079 Section 8 -25 Fit internal FDH ea 19.488 Section 8 -26 Fit internal NAP ea 8.878 Section 9: Cable Preparations External Locations (including FDHs) section 9 -17 4 fiber Cable and Preparation Per Cable End 1.967 section 9 -01 24 fibre cable end preparation Per Cable End 3.920 section 9 -02 36 fibre cable end preparation Per Cable End 5.566 section 9 -03 48 fibre cable end preparation Per Cable End 4.668 section 9 -04 72 fibre cable end preparation Per Cable End 7.088 section 9 -05 96 fibre cable end preparation Per Cable End 7.583 section 9 -06 144 fibre cable end preparation Per Cable End 9.057 section 9 -07 288 fibre cable end preparation Per Cable End 15.222 section 9 -08 432 fibre cable end preparation Per Cable End 18.838 Internal Locations section 9 -09 24 fibre cable end preparation Per Cable End 4.571 section 9 -10 36 fibre cable end preparation Per Cable End 6.541 section 9 -11 48 fibre cable end preparation Per Cable End 5.644 section 9 -12 72 fibre cable end preparation Per Cable End 6.749 section 9 -13 96 fibre cable end preparation Per Cable End 7.850 section 9 -14 144 fibre cable end preparation Per Cable End 9.258 section 9 -15 288 fibre cable end preparation Per Cable End 14.282 section 9 -16 432 fibre cable end preparation Per Cable End 17.861 Section 10: Splicing and Related Items Prepare and splice fibre with cable preparation section 10 -01 External Locations ea 0.920 section 10 -02 Internal Locations ea 0.943 Prepare and splice fiber without cable preparation. section 10 -03 External Locations ea 0.667 section 10 -04 Internal Locations ea 0.667 section 10 -05 Fit Splitter in FDH. ea 1.256 section 10 -06 Fit FDH Patch Panel with SC/APC Connectivity 2.317 Identify fault location within the network , formulate a per fiber fault section 10 -07 repair strategy and communicate this solution to Oman Broadband. 8.445 Fiber Dispersion testing and characterisation section 10 -08 Set up and prepare testing location per location 36.472 section 10 -09 Conduct Chromatic dispersion test per fiber 6.367 section 10 -10 Conduct Polarisation Mode dispersion test. per fiber 6.877 Installation of Standard 19" Rack Optical Distribution Frame ea section 10 -11 with all accessories 9.960 section 10 -12 Installation of ODF Termination Panel ea 19.679 section 10 -13 Install Patch Cord (all lengths) ea 0.224 section 10 -14 Installation of wall mounted box (24 fibres) ea 6.496 section 10 -15 Installation of wall mounted box (36 fibres) ea 8.553 section 10 -16 Installation of wall mounted box (48 fibres) ea 9.744 section 10 -17 Installation of wall mounted box (72 fibres) ea 12.186 section 10 -18 Installation of wall mounted box (96 fibres) ea 13.290 section 10 -19 Installation of wall mounted box (144 fibres) ea 22.736 Section 11: Customer Connection Activities Survey customer building and create works package (SDU) per site section 11 -01 12.769 Survey customer building and create works package (MDU per site section 11 -02 2 – 8 Tenancies) 16.023 Survey customer building and create works package (MDU per site section 11 -03 9-30 Tenancies) 18.080 Survey customer building and create works package (MDU per site section 11 -04 31 tenancies and above) 20.787 section 11 -05 Power level testing at customer premises with OTDR. per test 3.132 section 11 -06 Installation and activation of ONT/WiFi Router per site 6.000 Regional Rate Variations item Governate % Uplift in BOQ rates % Uplift in BOM Rates 1 Dhofar 7.82% 4.16% 2 Al Wusta 7.18% 3.84% 3 Ash Sharqiyah 6.36% 2.88% 4 Ad Dakhiliyah 6.13% 2.76% 5 Adh Dhahirah 6.82% 2.76% 6 Muscat 0.00% 0.00% 7 Al Batinah 4.78% 1.90% 8 Al Buraymi 7.13% 3.88% 9 Musandam 10.75% 6.85%