Professional Documents
Culture Documents
Description
Technical Properties @ 25⁰C:
Flo-Grout EPCG is a high strength, non-shrink, pourable
Mixed density: 2.1 ± 0.1 g/cm3
epoxy resin grout suitable for grou ng gaps with
thicknesses up to 300 mm. Compressive
strength*:
≥ 85 MPa @ 7 days
Flo-Grout EPCG is a three component system having base ASTM C579-82,
and hardener as the resin part with the blended ready Method B
filler part. And based on actual installa on condi ons,
Flexural strength*:
adjus ng the quan ty of the filler part can be done with ≥ 30 MPa @ 7 days
ASTM C580-74
maintaining the needed proper es.
Tensile strength*:
≥ 12 MPa @ 7 days
Applications ASTM C307-83
Temperature @25oC
High fill of filler for thick Moderate fill of filler for Low fill of filler for
pours medium pours thin pours
Fill #1 Fill #2 Fill #3
Concrete surfaces should be dry. All tools should be cleaned immediately a er finishing
using a suitable epoxy thinner. Hardened materials
Holes drilled for anchor bolts should be thoroughly should be cleaned mechanically.
cleaned from dust and lose debris using suitable brush or
compressed air. Packaging
Mixing The full unit of Flo-Grout EPCG is with 106.5 kg consis ng
of Base, Hardener & 4 filler bags.
To ensure proper mixing, a mechanically powered mixer
or drill fi ed with suitable paddle should be used. Thicknesses and Size Limitations
The en re content of the Hardener pack should be added Flo-Grout EPCG can be applied in a single layer at
to the Base pack. Care should be taken to ensure that the thicknesses between 10 - 300 mm. For thicknesses
bo om and the product sides are thoroughly scraped and greater than 300 mm:
used. Mix the two components for 2 minutes. The filler
should be gradually added while mixing. Mul ple layers can be applied a er ini al curing of the
previous layer.
Mixing should con nue for 3 minutes or un l a uniform
consistency obtained. Yield
Placing and Finishing Approximately 50.5 litre for the full unit.
To obtain maximum flow distance, a side shu er feed If these condi ons are exceeded, DCP Technical
100 mm height should be erected and used to build the Department should be contacted for advise.
required head.
Formwork:
As the mixed grout possesses fluid characteris cs, all
formwork and shu ers should be water ght. This can be
achieved by sealing underneath the formwork and at the
joints by using an appropriate mas c.
Flo-Grout EPCG
Cautions More from Don Construction Products
03-0028-B-2021