Capacity Factor Table, %

BATTERY INFORMATION BEI 150 deg C 180 deg C MEMORY PLT BATTERY LIFE ESTIMATION
Battery Type BEI Capacity 5.5 Ah 4.5 Ah

Power Rating 5.5 Ampere Hrs Ambient 70 70 If sample rate <= 7 secs tool power is on all the time ULTRAWIRE
Capacity Factor 80 % 50 deg C 80 80 Otherwise powered up for 4 secs per sample / reading.
Available power 4400 mAH 100 deg C 70 80 Real time clock power consumption 500 uA.
Self Drain per day 1.0 % 150 deg C 80 90

TOOL TYPE: MPL QPS CCL QPC CFB/CFS PRT CWH CTF ILS PGR FDR FDD PDC Total
CURRENT, mA: 50 20 16 22 14 24 20 24 14 21 33 50 24 Current,mA
TOOLS IN STRING: 1 0 0 1 0 0 0 1 1 1 0 1 0 181

TOOL INSTRUCTIONS Total Power Used Cumulative RESULTS: mAH %


Sample interval, Hrs Sample Rate, Secs No of readings Current mAH mAH Total Available 4400 100.0
0.1 1 360 181.5 18.2 18 Total Used 4000 90.9
2 15 480 181.5 104.3 122 Self Drain 99 2.3
2 1 7200 181.5 363.0 485
6 15 1440 181.5 297.9 783 Total Left 301 6.8
2 1 7200 181.5 363.0 1146
6 15 1440 181.5 297.9 1444
2 1 7200 181.5 363.0 1807 Instructions:
6 15 1440 181.5 297.9 2105
2 1 7200 181.5 363.0 2468 Enter Battery Information. Estimate capacity factor allowing for a safety margin.
24 15 5760 181.5 1169.1 3637 Capacity Factor is estimation of % of theoretical total power that is recoverable.
2 1 7200 181.5 363.0 4000 Self drain is related to downhole temperature. For Lithium batteries it is low (assumed 1%).
4000 Enter Tool Type, Tool Current (from Sondex QC results sheet) and Tools Used in the PLT string.
Enter Tool Instructions: Consecutive Intervals in hours and Sample Rate in seconds.
Total length of program in hours: 54.1 Power Used: 4000 Rev 1.0 Feb 99

Remarks:

This spreadsheet is to be used as a guide only. As battery life is dependent upon so many variables, Sondex cannot be held liable for consequences resulting from it's use.