CONTENTS 

1.1Cables Assembly To Silo..............................................................................2 
21.2.Slave Box Assembly To Silo Roof .............................................................2 
2. Equipment List..............................................................................................3

2.1.Heat Control Cable’s Structure………..……................................................................3 

2.2. Slave Card’s Structure.................................................................................................... 5 

2.3. Master Or Pc Card’s Connection……………..............................................................7 

2.4. Master Card’s Structure................................................................................................ 9 

2.5. Connecting The Supply To Master Card................................................................10 

MYSILO Grain Storage Systems 2


1.1.Cables Assembly to Silo 

1.2.Slave Box Assembly to Silo Roof 

MYSILO Grain Storage Systems 3


 
2. EQUIPMENT LIST 

2.1.Heat Control Cable Structure 
2.2. Slave Card 
2.3. Master Card 
2.4. Feeder Part 

2.1.Heat Control Cable Structure 

Cables assembling to silo are shown on figure.1.1 and figure.1. 

MYSILO Grain Storage Systems 4


 
Figure.1.1:View of heat control cable’s head and extension wire. 

 
Figure.1.2:View of heat control cable’s part which is ready to assemble. 

Heat control cable consist of 3 wire as can be seen on figure 2.1 these are                 
respectively; 

 
MYSILO Grain Storage Systems 5
Figure.2.1:Heat control cables connection and structure 

1.The color red +5V input. 

2.White data input 

3.Black (‐)minus input.These connect to slave card respectively; 

Red+5V input 

White Appropiriate number prop input. 

Black Ground input   

Make  sure  the  cables  are  connected  correctly  ,otherwise  these  entries  would 
damage  both  the  card  and  cables  so  it  will  lead  to  not  give  the  measurement  of 
heat.                                                                                 
2.2.Structure Of Slave Card 

Structure  of  card  is shown in figure 2.4.Connection of card consist of 3 part.These


are respectively;

Section1:Connecting heat cencor cables.In this section the cables connect the 
place  with  according  the  custom  of  the  slave  card  +5v,prop  and  ground  input 
respectively. (Figure.2.3). 

Section2:Connecting the data lines.Data line’s cable’s outer sheath consist of 
purple  color.  This  cable  consist  of  two  wires  and  this  cable  move  the  data.These 
cables consist of red and gren colors and marked with “B” with“A”letters in board. 
Connect these cables the wires to where the same with letters and colors. 

Section3:Power line connection.This part is important too. Circuit card supply 
is 24V.These cables must be connect in places where is 24v and 0v according to the 
appropriate color and suitable polarized. 

MYSILO Grain Storage Systems 6


 
Figure.2.2:Heat cables connect the cables to the card without installing version. 

Figure.2.3:Heat cables connect the cables to the card after inserted it into the next 
version. 

MYSILO Grain Storage Systems 7


 
Figure.2.4:Heat cables to connect the card and the structure of links to. 
2.3.Master Or PC Card Connection 

Master card where there is no connection to computer must be mounted to 
silo  which  is  height  of  1.5  m  from  ground.  (Figure.2.8).When  connected  to  the 
computer,it  should  be  mounted  somewhere  near  the  computer.  Master  card’s 
circuit diagram and connection type is seen on figure.2.7. 

MYSILO Grain Storage Systems 8


 

Figure.2.5:Master card’s cables without installing version. 

Figure.2.6:Master card’s cables after installed version. 

MYSILO Grain Storage Systems 9


 
Figure.2.7:Master card’s connection and structure. 

MYSILO Grain Storage Systems 10


 
Şekil.2.8:Master card assemblt to silo.It must be height of 1,5m from ground. 

2.4.Master Card Structure 

Card’s structure is seen on figure.2.6.Card’s connection consist of two section 
“2”.    

Section1:The data of card is output line.This line is shown data output which 
is required to communicate with slave cards where is located on silo’s upper.Purple 
color cable’s gren(B) and red (A) edges should be connected respectively and other 
edges should be taken to connect the card.   

Section2:24V  supply  fort  he  card  needs  to  work.These  edges  should  be 
connected in place where is on card respectively to be “+24V”and“0V”and not to be 
confused their directions.Master card also makes the slave cards’ supplies    from 24 

MYSILO Grain Storage Systems 11


volt output. Blue “+24V”and Brown“0V”edges should be done by connecting.   
2.5. Connecting The Power Supply Of Master Card   

Switching power supply is used as a supply 24 volt input and 24 volt output. 
Shape of power supply connection is seen on figure.2.9.The connection should be 
made in this way and cconnected to Master card.   

 
Figure.2.9:Supply the heat control system. 

 
Figure.2.10:Heat control system’s supply part of photo. 

MYSILO Grain Storage Systems 12


Heat Control System Complete Connection Diagram   

MYSILO Grain Storage Systems 13