LONG SPAN STRUCTURES

FINAL STUDIO GROUP ASSIGNMENT


Mentored by : Prof. Sarath KT

Disha Bhagat
Joel George Daniel
Gaurav Bohara
PLACEMENT DETAILS DETAILS
Why steel barrel vault ?
The structure is a market place A B C
B C
Acrylic Cladding 10mm thick
Steel Struts 10mm dia
Steel Purlin (50.8 x 25.4)
C C

and thus we need a long span 3 3 Steel Upper chord 30mm dia
Steel Lower chord 30mm dia
Steel beam ISMB 500

structure so that we get large Steel Base Plate (150 x 450)


PVC pipe 150mm dia
1 1 1 1 Angle cleat detail
open space. Scale (1:10)

So we have given a steel barrel Steel column ISMB 450

vault as a roof. 2 2
Steel Gusset Plate
Steel Base Angle
Steel Base Plate (580 x 280)
C
Pedestal (350 x 640 x 500) C
GL Plinth 450mm thick

Section AA' Placement of steel Placement of steel Gusset plate detail


BLOCK
Scale (1:100) Base plate column Scale (1:10) Base angle detail
'C' BLOCK
Scale (1:20) Scale (1:10)
'F' Scale (1:20)

BLOCK RAMP SLOPE 1:12


JOINERY DETAILS
'G'
1 1

BLOCK

BLOCK
'J'
BLOCK 'E'
'A' Acrylic Cladding 10mm thick
A B C
Steel Purlin (50.8 x 25.4) Acrylic Cladding 10mm thick
Steel Base Angle 10mm thick Steel Purlin (50.8 x 25.4)
BLOCK Steel Gusset Plate 15mm thick PVC Gutter 200mm dia
'H' PVC Gutter
BLOCK
'D'

Steel Upper chord 30mm dia


Steel Angle cleat 10mm thick Steel Lower chord 30mm dia Steel Upper chord 30mm dia

Key Plan Plan Scale (1:200) Steel column ISMB 450


Steel Base Plate (280 x 580)
Pedestal (380 x 680 x 500)
Steel Base Plate (190 x 250) Steel Lower chord 30mm dia
Steel Base Plate (190 x 250)
PVC Gutter Pipe 150 dia

A B C Steel beam ISMB 500


Steel Base Plate (150 x 450) Steel beam ISMB 500
Steel Base Plate (150 x 450)
Steel column ISMB 450
3 3 Steel column ISMB 450

Steel column ISMB 450


Steel beam ISMB 500 Detail at A Scale (1:10) Detail at B Scale (1:10) Detail at C Scale (1:10)
Purlin (50.8 x 25.4)
Struts 10mm dia

Steel column ISMB 450

Steel Gusset Plate 15mm thick


Steel Angle Plate 10mm thick
Steel Angle cleat 10mm thick
Steel Base Plate (280 x 580)
Pedestal (380 x 680 x 500)

2 2
A A'

Detail at D Scale (1:20)

PVC Gutter 10mm thick

Acrylic Cladding 10mm thick


Steel Purlin (50.8 x 25.4)
A Steel Upper chord 30mm dia
1 1 Steel Lower chord 30mm dia
Steel Base Plate (190 x 250)
PVC Pipe 100mm dia
Steel beam ISMB 500
D Steel Base Plate (150 x 450)

Steel column ISMB 450


A B C

Isometric View
PLAN Scale (1:100) Scale (1:100) Detail at E Scale (1:20)

By : Sign: Sheet No.:

Steel Barrel Vault Disha Amrutlal Bhagat


Gaurav Puran Bohara
Joel Goerge Daniel 01
WHY COMPOSITE BEAMS?
BEAM DETAILS (1:50)
SINCE IT'S A COMMERCIAL BUILDING, LONG SPAN
SPACES ARE REQUIRED WITH SERVICES ABOVE THE AHU UNIT

FLOOR. HENCE COMPOSITE BEAM WITH WEB OPENING IS SERVICE LIFT

PRIMARY BEAM ISMB 500


THE OPTIMUM OPTION.
LIFT LIFT

500
DESIGN CRITERIA NOMENCLATURE CANTEEN SPACE 21600
D = 1.5 of original beam
e > 3in(7.6cm) e PRIMARY BEAM - ISMB 500 CASTELLATED BEAM (I SECTION SYMMETRICAL)
ho < 8 e

ho
FIRST FLOOR PLAN

D
e

780
1 2 3 4 5 6 7 8 9 10 12 13 14 15 17 18 19 20 21 22 23 24
60°

19950

SECONDARY BEAM - ISMB 450 (I SECTION)


15 20

450
B'
15600
B

B 1

SECONDARY BEAM - ISMB 450 CASTELLATED BEAM (I SECTION SYMMETRICAL)


C1 500 X 500 C48 500 X 500

675
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18

15200
A A'

JOINERY DETAILS
14575

15075

REINFORCEMENT BARS (16MM DIA)


CONCRETE SLAB (130MM THK) CONCRETE SLAB (130MM THICK)
ANCHOR BOLT (10MM DIA) SHEAR STUDS (19MM DIA X 76MM)
to be placed without interrupting the welded onto the beam
1
reinforcement of Column
BOLTS
1

A A
C9 500 X 500 C12 500 X 500 L ANGLE (25X25X5MM) AC DUCT 350MM DIA
C - C DIMENSION 3620 3305 3305 3305 3305 3620
BEAM TO BEAM OUTER
3295 3155 3155 3155 3155 3440 BASE PLATE(780X300X30MM)
C - C DIMENSION
20450
COLUMN TO COLUMN OUTER 19950
(Flushed with the Column)

ISMB 450 CASTELLATED


CENTERLINE PLAN (1:100) WELDED ONTO ISMB 500 CB
B
15 20
A. PRIMARY BEAM TO COLUMN CONNECTION (1:25) AC DUCT PASSING THROUGH THE WEB OPENING (1:5)

1 2 3 4 5 6 7 8 9 10 12 13 14 15 17 18 19 20 21 22 23 24

970
A B

SECTION AA'
CONCRETE SLAB (130MM THICK)
(1:100) REINFORCEMENT BARS (16MM DIA) EDGE TRIM SHEET BOLTED ONTO BEAM
SHEAR STUDS (19MM DIA X 76MM)
500 19950 500 RESTRAINT STRAP
welded onto the beam MP 76 STEEL PROFILE SHEETS

BOLTS L ANGLE
ISMB 450 CASTELLATED
WELDED ONTO ISMB 500 CB
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 ISMB 500
CASTELLATED ISMB 500 CASTELLATED
FIXED ONTO A BASE PLATE
C
SECTION BB' (400X780X30MM)
3645

2980
2865

(1:100)
B. PRIMARY BEAM TO SECONDARY BEAM CONNECTION (1:25) C. SLAB DETAILS ALONG WITH EDGE DETAIL (1:25)
14575

By : Sign: Sheet No.:

Composite Beam Layout Disha Amrutlal Bhagat


Gaurav Puran Bohara
Joel Goerge Daniel 02
WHY SPACE FRAME? GROUND FLOOR PLAN

THE CURVILINEAR SPACE FRAME EXISITING BUILDING

SERVES THE FUNCTION OF


PROVIDING A ROOF TO A
B
C

OUTDOOR SEATING SPACE OF A


CAFETERIA AND IT ADDS 1940

6843
AESTHETIC VALUE TO IT.

6110
4850

5107
450 x 600MM R.C.C. COLUMN

4860

4860
A.H.U. ELECTRICAL ROOM
ROOM

SCALE 1:500
GL GL

SECTION AA' SECTION BB'


A B C SCALE 1:100
SCALE 1:100
A

2 2
C6 600 x 450 C5 600 x 450 C4 600 x 450

40MM DIA MERO MEMBER

60MM DIA MERO NODE


HEAD

10195
150MM THICK BRICK WALL SLEEVE
150MM DEPTH METAL PANEL
30MM THICK BASE PLATE
30MM DEPTH HOLLOW BOX DETAIL AT 'B'
SECTION(PURLIN) SCALE 1:5
60MM DIA MERO NODE
B B' 40MM DIA MERO MEMBER
1 1
C1 600 x 450 C2 600 x 450 C3 600 x 450 12MM ADJUSTMENT SPACE
FILLED WITH GROUT
3MM DIA HOOK BOLT
10110 9590
19700
A B C
PLAN
A'

CENTERLINE PLAN 6MM DIA HOOK BOLT


SCALE 1:100 150MM DEPTH METAL PANEL

30MM DEPTH HOLLOW BOX


CHANNEL
A B C
60MM DIA MERO NODE
2 2
40MM DIA MERO MEMBER
10200
12215

15MM DEPTH SUPPORT CONES


WITH BEARINGS
450MM R.C.C. COLUMN 25MM THICK BASE PLATE

1 1
3MM DIA HOOK BOLT
DETAIL AT 'A'
2015

SCALE 1:5
2230 10110 9590
21930

A B C
DETAIL AT 'C'
SCALE 1:5
PLAN

ROOF PLAN
SCALE 1:100
ALL DIMENSIONS ARE IN MM.

By : Sign: Sheet No.:

Curvilinear Space Frame Disha Amrutlal Bhagat


Gaurav Puran Bohara
Joel Goerge Daniel 03