CTRIC TRACTION ELEVATORS FOR THE SHUBAILY GRAND MALL, AL KHOBAR:

COMPLIANCE BY WAM
No deviation

No deviation

No deviation

No Deviation

No Deviation
No Deviation
No Deviation

No Deviation

No Deviation
No Deviation

NO Deviation
NO Deviation

NO Deviation

NO Deviation
ment SECTION 14210 for the ELECTRIC TRACTION ELEVATORS FOR THE SHUBAILY GRAND MALL, AL KHOBAR:

REMARKS BY WAM
Noted. These services will be provided by other sub contractors and WAM
will only coordinate as mentioned in the section 14210.

Provision for telephone wiring from machine room to the elevator cabin will be
arranged by WAM. WAM will provide 5 station intercom only . Telephone ,if
required to be provided by others) with wiring upto lift controller.

Noted. These services will be provided by other sub contractors and WAM
will only coordinate as mentioned in the section 14210.
WAM will provide the interface in the contorl panel for card reader and
traffic monitoring.

Noted. To be done by others.

Noted. To be done by others. WAM will provide wiring from cabin to


machine room only.
WAM will supply as mutually agreed.
Noted. To be provided by others. WAM will provide interface with the
elevator control panel

Noted. To distinguesh between normal power and generator power, lift


controller needs dry contact signal from the power transfer panel for each
lift controller. To be provided by related contractor. Otherwise this feature
cannot be achived.
Noted. WAM submitted it with the offer.
TO BE SUBMITTED LATER AS AGREED WITH THE PROJECT
ENGINEER

Noted. The Firefighters' Control Panel and Remote Wiring. Will be


supplied and installed by related sub-contractor. WAM will coordinate and
connect the elevator control according to the planned scheme of the
building. Kindly note that to override the emergency power during fire
fighting situation , all lifts controllers need dry contact signal to differentiate
between normal and emergency power as mentioned above.

Noted. Provision for firefighter telephone jack (1 twisted pair of cable from
machine room to cabin) will be provided only. Telephone jack will be
supplied and installed by related sub-contractor. WAM will coordinate
Tthe Firefighters' Control Panel and Remote
Wiring.will be supplied and installed by related sub-contractor. WAM will
coordinate and connect the elevator control according to the planned
scheme of the building.
Noted. The equipment will be supplied in accordance with the Europian
Safety Standards EN81-20 Tthe Firefighters'
Control Panel and Remote Wiring and fire fighter telephone jack.will be
supplied and installed by related sub-contractor. WAM will coordinate and
connect the elevator control according to the planned scheme of the
building.

Noted

Noted
- FIRE FIGHTER'S PHASE KEY SWITCH TO BE PROVDED IN COP OF
DESIGNATED LIFTS
- WE WILL PROVIDE 05 STAGE INTERCOM. ONE INTERCOM TO BE
USED FOR FIRE FIGHTER'S USE. - FIIRE FIGHTER'S CONTROL
PANEL AN DIT'S FUNCTIONS TO BE DISCUSSED AND CLARIFIED BY
TH ECUNSULTANT / ROJECT ENGINEER.
Compliance sheet for the points high lighted in the specification document SECTION 14210 for the ELECTRIC TRACTION E

ROJECT MANAGER

CIFIED ELSEWHERE:
uctors and Devices
nience outlets in pit, machine room and overhead machine room space.

e wiring to machine room junction boxes.

erface boards, security computer, monitor and keyboard for encoding, overriding and monitoring restricted access floors

peakers.

nce and 24-hour emergency call-back service for 1 year


eptance by the Owner. Systematically examine, adjust, clean and lubricate all equipment. Repair or replace defective

uipment. Repair or replace defective parts using parts


condition.
Contract
Maintenance Program): Quote monthly cost for 5-year maintenance agreement commencing on completion of
bmit
mencing on completion of the defects liability period. Submit
the Owner's standard preventive maintenance

and PL1 to PL15) 6. Operational Control: Simplex-Duplex Selective Collective, Microprocessor


ry 7. Motor Control: DC Variable Voltage Microprocessor
op Feedback and Automatic Stopping 33. Additional Features:
Fire fighter Service - Standby Power Transfer (Automatic to Primary
n Fire Control Panel - Firefighters' Control Panel and Remote Wiring - Ceiling
amera (corner mount)
r Lighting. Provide Separate Constant Pressure Test Button In Car Service Compartment Or On Car Operating

ess Type Elevators (Elevators # SL-1 to SL-8) 33. Additional Features:


- Fire fighter Service - Standby Power Transfer (Automatic to Primary
n Fire Control Panel - Firefighters' Control Panel and Remote Wiring - Sill support
- Firefighters' Telephone Jack - Battery Pack Emergency Car
onstant Pressure Test Button In Car Service CompartmentOr On Car Operating Panel
o FL-9) 5. Supervisory Control: Group Automatic Microprocessor Based System Non-Proprietary
- Standby Power Transfer (Automatic to Primary Floor) with Manual Override in Fire
cess and signage - Firefighters' Control Panel and Remote Wiring - Maintenance
- Firefighters' Telephone Jack

2. Provide separate key-operated group rotary switch in the Firefighters' Control Panel.

Door Header: Construct of minimum 12 gauge steel, shape to provide stiffening flanges.
high-speed, heavy-duty, master door operator capable of opening door at no less than 0.75m/s. Accomplish
mm of door movement. Open doors automatically when car arrives at a floor.
L
m diameter raised floor pushbuttons which illuminate to indicate call registration. Include 1.60 mm high
ed on face of button.
tom of car operating panel to ring bell located on elevator,and sound distress signal at control panel. Illuminate

II key switch with engraved instructions per local requirement. Include light jewel, buzzer and call cancel button.
9.
e jack with bezel matching adjacent controls. 11/c.
h. U.1/a.
tactile symbol engraved signage and Braille 2.
car and Firefighters' panel, with four shielded wires to machine room junction box. Jack bezel shall match

vided by Life Safety Contractor behind front return panel


ne room junction box.
Ventilation: Three-speed exhaust blower mounted to car canopy on isolated rubber
, Model AA with diffuser and grille
D DISPLAY PANEL
el: Locate in fire control location. Fixture faceplate, No. 4 brushed
g the following features:
selection switch and power status indicator.
h-mounted box with lockable hinged cover. Engrave instructions for
uthority requirements.