Professional Documents
Culture Documents
Data Type
1. Rating of Condenser mw MW 500 B/G
2. LBTP of Condenser LBTP mm 14630 B/G
3. Width of condenser Shell CsW mm 8660 B/G
4. Pitch of Support Plates SpPc mm 770 B/G
5. Elevation of Water boxes Horizontal center line WbCL mm 3800 B/G
6. Elevation of Hot well HwEL mm -1679 A/G
7. Elevation of High High level HHL mm 626 A/G
8. Height of Water Boxes With flange WbHt mm 6500 B/G
9. Distance between Condenser Center Line and CclFD mm 10 A/G
Water Box Flange
A – Advance User Input B - Basic user input G – Global input P - Input taken by program other than 1
expressions
Shell Internal Details (160- 28), Var.0.1
26. Distance of First Tube bundle center line from TbCCL mm 612 P
condenser center line
27. Pitch of Tube bundles TbPc mm 612 P
28. Number of Horizontal Tie Rod of Water chamber WcHTrn no 6 A
29. Overlap Distance of Support Tube Plate and SpJpD mm 20 A
Joining Plate
Tube Layout:
Material:
Plates:
Round Bar:
Flat:
A – Advance User Input B - Basic user input G – Global input P - Input taken by program other than 2
expressions
Shell Internal Details (160- 28), Var.0.1
I-Beam:
Welding Edge:
53. Weld root for above 5mm and less than 10mm Plates Wr1 mm 1 P
54. Weld root for less than 50mm Plates Wr2 mm 2 P
55. Weld root for more than 50mm Plates Wr2 mm 3 P
56. V-Butt welding Edge angle Edge1 deg 30 P
57. Single Bevel Butt welding Edge angle Edge2 deg 50 P
I-Beam:
A – Advance User Input B - Basic user input G – Global input P - Input taken by program other than 3
expressions