You are on page 1of 3

Upper Dome Wall FWB Side (160-21), Var.0.

Upper Dome Wall (FWB Side) (160-21)

GLOBAL INPUT DATA:

S.No. Description Variable Unit 500 MW

Data Type
1. Rating of Condenser mw MW 500
2. LBTP of Condenser lbtp mm 14630
3. Elevation of TG Center Line TgCl mm 18000
4. Length of condenser neck CneckL mm 8700
5. Elevation of Water boxes Horizontal center line WbClEl mm 3800
6. Height of Water Boxes With flange WbHt mm 6500
7. Inclination of condenser from horizontal IcAng deg 0.5
8. Distance of Upper I-beam of Upper dome from TG UdwUIb mm 2900 *
Center line
9. Distance of lower I-beam of Upper dome from TG UdwLIb mm 4520 *
Center line
10. Distance of Lower Dome Walls & Upper Dome Joint LdwUel mm 5300
from TG Center line
11. Distance of Upper dome from TG Center line UdwD mm 1900 *
12. Width of Upper Dome Wall UdwFsW mm 7180 *
13. Thickness of Dome Wall DwTk mm 16 *
14. Width of left side plate of upper dome wall (fwb UdwFsLspW mm 2480 *
side)
15. Distance of I-Beam from Plate Edge IbPd mm 50 *
16. Distance of I-Beam Flange from Plate end IbFd mm 30 *
17. Height of Dome Wall Stiffeners DwSh mm 225 *
18. Thickness of Dome Wall Stiffeners DwStk mm 16 *
19. Distance of Stiffener no.1 form CL of condenser WbS1D mm 267 *

20. Pitch of Stiffeners Water box Side WbSPc mm 492 *

21. Distance of Stiffening pipes Pad (Water box Side) WbSpD mm 1480 *
22. Distance of I-Beam from Plate Edge DwIbPD mm 20 *
23. Distance of Horizontal Weld seam from I-Beam HWSD mm 90 *
24. Site Margin UdwSm mm 50 *
25. Length of LPC plate LpcPL1 mm 320 *

A – Advance User Input B - Basic user input G – Global input P - Input taken by program other 1
than expressions
Upper Dome Wall FWB Side (160-21), Var.0.1

I-Beam, Channel & Angle Section:

26. Size of I-Beam of Dome Wall DwISMB mm 250 P

Input Taken by Program from Data Table of Standard Parts:

Lifting Lug:

27. Thickness of Lifting Lug LgTk mm 50 P


28. Width of Lifting Lug LgW mm 180 P
29. Height Of Lifting Lug LgHt mm 140 P
30. Diameter of Lifting Lug Hole LgHD mm 47 P
31. Radius of Lifting Lug LgR mm 70 P
32. Hole radius of lifting lug LgHr m 3 P
33. Chamfer of Lifting Lug edge LgC mm 3 P

Dome Wall Pad:

34. Thickness of Dome Wall Pad DwPdTk mm 40 P


35. Outer Diameter of Dome Wall Pad DwPdOd mm 320 P
36. Inner Diameter of Dome Wall Pad DwPdId mm 80 P
37. Diameter of hole in pad for inert gas DwPdHD mm 8 P

Dome Wall Gusset Plate:

38. Medium Gusset Plate length DwMGpL mm 800 P


39. Sort Gusset Plate length DwSGpL mm 400 P

I-BEAM

40. Size of I-Beam of Dome Wall DwISMB mm 250 P


41. Width of I-Beam of Dome Wall DwIbW mm 125 P
42. Thickness of Web of I-Beam of Dome Wall DwIbWTk mm 6.9 P
43. Thickness of Flange of I-Beam of Dome Wall DwIbFTk mm 12.5 P
44. I-Beam Web radius DwIbWr mm 13 P
45. I-Beam Flange radius DwIbFr mm 6.5 P

Input Taken by Program from Data Table of WTI:

46. Width of Water boxes Rectangular flange WbFW mm 140 P

Input Taken by Program from Data Table of Welding Standards:

A – Advance User Input B - Basic user input G – Global input P - Input taken by program other 2
than expressions
Upper Dome Wall FWB Side (160-21), Var.0.1

47. Weld root for above 5mm and less than 10mm Plates Wr1 mm 1 P
48. Weld root for less than 50mm Plates Wr2 mm 2 P
49. Weld root for more than 50mm Plates Wr2 mm 3 P
50. V-Butt welding Edge angle Edge1 deg 30 P
51. Single Bevel Butt welding Edge angle Edge2 deg 50 P

A – Advance User Input B - Basic user input G – Global input P - Input taken by program other 3
than expressions