Please identify all
CONDENSER-1 DATA changes in the document
with revision tag.
CONDENSER-1
Corresponding to HBD Doc. No. PE-DG-445-100-N150, R00 (DWG Sheet No. 675-STE-
TC-S0211, R01)
Corresponding to HBD Doc. No. PE-DG-445-100-N150, R00 (DWG Sheet No. 675-STE-
TC-S0211, R01)
Tube End Loss (Combined inlet and Outlet) = 0.99 ft -- Curve A (fig .8)
Water Box Inlet Loss = 0.86 ft -- Curve B (fig. 8)
Water Box outlet Loss = 0.26 ft -- Curve C (fig.8)
= 0.00642X(5.41) 1.75
(0.9282) 1.25
For Condenser 1:
Temperature correction factor = 0.954 (figure 7)
(Corresponding to average CW temp.
of 35.205 deg C (average of CW inlet 33 deg C
& CW outlet 37.41 deg C in Condenser 1))
For Condenser 2:
Temperature correction factor = 0.938 (figure 7)
(Corresponding to average CW temp.
of 39.665 deg C (average of CW inlet 37.41 deg C
& CW outlet 41.92 deg C in Condenser 2))
Friction loss at 39.665 deg C = 0.1352 x 0.938
Avg. CW temp. = 0.1268 ft / ft of length
=0.1268 m/m of length