Professional Documents
Culture Documents
OEB (Electro-boiler)
remedied
o.k.
Not o.k.
Maintenance work:
Recommen Maintenan
ded ce time in
(see also Service Manual (SM), remedy (if minutes
in particular chapters 4 & 5 & 6) required!) (incl.
remedy)
Check installation (Checklist in installation Correct 20
manual) installation
544485319.doc 2/4
remedied
o.k.
Not o.k.
Maintenance work:
Recommen Maintenan
ded ce time in
(see also Service Manual (SM), remedy (if minutes
in particular chapters 4 & 5 & 6) required!) (incl.
remedy)
Mechanical parts check (=> SM 4.6.4):
Check water hoses with joints for leak tightness & Tighten / 15
wear replace
SG drain pump leak tightness & wear (only for Replace 20
OEB / OGB) ‘O’ ring
Leak tightness between oven cavity and Change 15
electronics chamber seals
(seals & silicone)
Retighten all sensors (in oven cavity, condenser, Change 10
bypass, steam generator) & check leak tightness seals
Check KTM sensor in oven cavity Change 5
sensor
Check that plating racks are stable (weld points) Replace 5
EHG
Check leak tightness & condition of hot air Replace 20
heating seals
Rotary lever closure: Adjust / 20
Check for wear and that it is correctly adjusted: replace
- Wear on collar lug & worm?
- Adjust door handle mounting?
- Door magnet working? (Service programme
r23)
- Adjust collar?
Mechanics of disappearing door:
Check for wear and excessive abrasion and that Asjust / 25
it is firmly in position: replace
- Contact surface of tracks & rollers?
- Mounting of rollers?
- Door stop on appliance?
- Top support strip on the slide plate?
- Slide block in door guide bar?
- Guide rail on bottom right?
- Top/bottom hinge (position & wear)?
544485319.doc 3/4
remedied
o.k.
Not o.k.
Maintenance work:
Recommen Maintenan
ded ce time in
(see also Service Manual (SM), remedy (if minutes
in particular chapters 4 & 5 & 6) required!) (incl.
remedy)
Functional test & electr. safety:
Steam measurement: Test in oven programme Clean B5 10
Steaming 100°C (=> switches SG heating off)
Test in oven programme HLD 150 °C (=> Clean B5 10
switches SG heating over to hot air heating at
approx. 90°C)
Check electrical safety in accordance with local Check 25
regulations (in Germany BGV A3, VDE 0701 /
0702)
544485319.doc 4/4