STC-ECO

Canned, Clean and Smart

The first canned and hermetically sealed motor/


compressor solution for dirty gas application
for onshore, offshore and subsea

Gas Electric Partnership


February 2009, Houston Texas

Presenter: Chris Kapp


Siemens Energy Oil & Gas
Protection notice / Copyright notice
1 Gerold Hake / Chris Kapp Energy Oil & Gas
STC-ECO
Why go Canned and Seal less ?

Customer Feedback
What is the weakest link in your compression It is about RELIABILITY!
compressor system?

Upstream gas
treatment systems
ƒ OREDA database:
Compressor unit
MTBFmotor driven dry-wet compressor unit =1.8 year
Auxiliary systems

Human ƒ O&G Major: 80% of all forced


What is the average MTBF of your dry wet
compressor units?
outages are caused by unforeseen
MTBF < 1 year
liquid ingress into compressor
1 year < MTBF < 2 year

2 year < MTBF < 5 year


ƒ Seal supplier: 80% of all seal
MTBF > 5 year failures are caused by contamination
What is the weakest link in your dry-wet
compressor units?
Internals: labyrinths, impellers,
SAFETY And ENVIRONMENT !
etc.
Bearings and/or lube oil system
ƒ ZERO Emissions: Easy Permitting
Dry gas seals and/or their
support systems
Control & Monitoring systems ƒ No Hydrocarbons, No F&G System
Protection notice / Copyright notice
2 Gerold Hake / Chris Kapp Energy Oil & Gas
STC-ECO Sm
The concept ar t

Single casing Cle


an
hermetically sealed

Induction motor with compact


end winding, liquid cooled

Canned axial/radial Active


Magnetic Bearings & back-ups

Single, solid rotor

Can
Canned motor ned

Multi-stage compressor
3D Animation
Protection notice / Copyright notice
3 Gerold Hake / Chris Kapp Energy Oil & Gas
STC-ECO
In-house testing

ECO-II Factory Acceptance Testing


• PTC 10, Type 2
• PTC 10, Type 1

Protection notice / Copyright notice


4 Gerold Hake / Chris Kapp Energy Oil & Gas
STC-ECO
Field verification – NAM Vries4

ƒ NAM Vries 4 is a centralized, gas


gathering, treatment and withdrawal
station onshore

ƒ Process gas is wet natural gas with a


number of contaminants like sand,
salt, mercury.

ƒ The units passed 12.000 operating


hours in December 2008 and
availability close to 100% and was
found to be in excellent condition

Protection notice / Copyright notice


5 Gerold Hake / Chris Kapp Energy Oil & Gas
Unit Inspection
• Compressor internals dirty but OK. Labyrinths slightly worn, but within
specifications

Page 19
Unit Inspection
• Active Magnetic Bearings are in good condition
• Dye penetrant test can surfaces revealed no cracks
• Helium gas tightness test confirmed gas tightness
• Endoscope inspection of bearing cavities revealed no internal fouling or
moisture

Page 20
STC-ECO
Second order K-Lab

ƒ April 2007: Contract-award


ƒ Unit will be extensively tested at
Statoil Test Facility, Kårstø Norway
[K-lab]

ƒ Complementary testing on liquid


tolerance simulating transient liquid
carry over upstream scrubber

ƒ 3-Days fill-up with seawater, drain


and start

ƒ Testing is vital step for Statoil and its


partners in the Åsgard Field towards
subsea compression by 2013
Protection notice / Copyright notice
6 Gerold Hake / Chris Kapp Energy Oil & Gas
STC-ECO
The Range

• One common concept • Four frame sizes


• Two versions • Large application flexibility

Protection notice / Copyright notice


7 Gerold Hake / Chris Kapp Energy Oil & Gas
STC-ECO
Wrap up

¾ STC-ECO with its canned design offers

9 increased SAFETY
9 increased UPTIME
9 ZERO emissions

In the most challenging O&G applications

¾ Critical applications requiring zero emissions


for safety, corrosion and environmental
reasons.

¾ First installation Vries4 has proven the


concept beyond doubt.
Protection notice / Copyright notice
8 Gerold Hake / Chris Kapp Energy Oil & Gas