Professional Documents
Culture Documents
Interpact INS/INV
40 to 2500 A
Modularity…
the sky is the limit
Installation recommendations 63
Schneider Electric 1
16 Schneider Electric
Functions and characteristics
Presentation 2
General characteristics 18
Switch-disconnector selection 20
Interpact INS40 to 160 20
Interpact INS250-100 to 630 24
Interpact INS630b to 2500 28
Interpact INV100 to 630 32
Interpact INV630b to 2500 36
Complete source-changeover assembly selection 40
Interpact INS250-100 to 630 40
Installation 44
Connection 45
Interpact INS40 to 160 45
Interpact INS250 to 630 / INV100 to 630 48
Interpact INS630b to 2500 / INV630b to 2500 51
Electrical and mechanical accessories 46
Interpact INS250 / INV100 to 250 46
Interpact INS320 to 630 / INV320 to 630 47
Interpact INS630b to 2500 / INV630b to 2500 50
Connection accessories 52
Distribution blocks 52
One-piece spreader 53
Insulation of live parts 54
Auxiliary contacts 55
Current measurements 56
Rotary handle 57
Coupling accessories 58
Disabling device closing 59
Switching to a replacement source 60
Accessories 61
Installation recommendations 63
Dimensions and connection 85
Additional characteristics 103
Catalogue numbers 113
Schneider Electric 17
Functions and Switch-disconnector selection (cont.)
characteristics Interpact INS40 to 160
Number of poles
Electrical characteristics as defined by IEC 60947-1 / 60947-3 and EN 60947-1 / 60947-3
Conventional thermal current (A) Ith at 60 °C
Conventional thermal current Ithe at 60 °C
in enclosure
Rated insulation level (V) Ui AC 50/60 Hz
Impulse-withstand voltage (kV) Uimp
Rated operational voltage (V) Ue AC 50/60 Hz
DC
Interpact INS80 switch-disconnector
Rated operational voltage AC20 and DC20 (V) AC 50/60 Hz
Rated operational current (A) Ie Electrical AC 50/60 Hz
220-240 V
380-415 V
052168_A
440-480 V (1)
500 V
660-690 V
Electrical DC
125 V (2P in series)
250 V (4P in series)
Rated operational power AC23 (kW) Electrical AC 50/60 Hz
220-240 V
230 V (NEMA)
380-415 V
440 V
Interpact INS160 switch-disconnector 480 V (NEMA)
500-525 V
660-690 V
Rated duties uninterrupted duty
intermittent duty
059202_A
20 Schneider Electric
Functions and Switch-disconnector selection (cont.)
characteristics Interpact INS40 to 160 (cont.)
11 15 22 22 37 45
7.5 15 15 22 37 45
20 30 37 45 55 75
22 30 37 55 55 90
22 30 30 55 75 90
18.5 22 22 55 75 110
– – – 55 75 90
b b b b b b
class 120 - 60 % class 120 - 60 % class 120 - 60 % class 120 - 60 % class 120 - 60 % –
15 15 15 20 20 20
75 75 75 154 154 154
3000 3000 3000 5500 5500 5500
1730 1730 1730 3175 3175 3175
670 670 670 1230 1230 1230
550 550 550 1000 1000 1000
b b b b b b
20000 20000 20000 15000 15000 15000
AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A
1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500
1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500
1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500
1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500
– – – – – – 1500 1500 1500 1500 1500 1500
DC22A DC23A DC22A DC23A DC22A DC23A DC22A DC23A DC22A DC23A DC22A DC23A
1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500
b b b b b b
– – – – – –
b b b b b b
III III III III III III
– – – – – –
Schneider Electric 21
Functions and Switch-disconnector selection (cont.)
characteristics Interpact INS40 to 160 (cont.)
D W
22 Schneider Electric
Functions and Switch-disconnector selection (cont.)
characteristics Interpact INS40 to 160 (cont.)
b b b b b b
– – – b b b
b b b – – –
b b b b b b
b b b b b b
– – – b b b
– – – – – –
– – – – – –
– – – b b b
– – – – – –
– – – – – –
b b b b b b
– – – – – –
– – – – – –
– – – – – –
b b b b b b
b b b b b b
b b b b b b
b b b b b b
– – – – – –
b b b b b b
– – – – – –
b b b b b b
– – – b b b
0.7 < C < 1.3 0.7 < C < 1.3 0.7 < C < 1.3 1.4 < C < 2 1.4 < C < 2 1.4 < C < 2
b b b b b b
– – – – – –
– – – – – –
– – – – – –
– – – – – –
b b b b b b
b b b b b b
b b b b b b
– – – – – –
– – – – – –
8 8 8 8 8 8
90 x 81 x 62.5 90 x 81 x 62.5 90 x 81 x 62.5 135 x 100 x 62.5 135 x 100 x 62.5 135 x 100 x 62.5
90 x 81 x 62.5 90 x 81 x 62.5 90 x 81 x 62.5 135 x 100 x 62.5 135 x 100 x 62.5 135 x 100 x 62.5
0.5 0.5 0.5 0.8 0.8 0.8
0.6 0.6 0.6 0.9 0.9 0.9
115 x 190 x 55 115 x 190 x 55 115 x 190 x 55 160 x 260 x 55 160 x 260 x 55 160 x 260 x 55
Schneider Electric 23
Functions and Switch-disconnector selection (cont.)
characteristics Interpact INS250-100 to 630
Number of poles
Electrical characteristics as defined by IEC 60947-1 / 60947-3 et EN 60947-1 / 60947-3
Conventional thermal current (A) Ith at 60 °C
Conventional thermal current Ithe at 60 °C
in enclosure
Rated insulation level (V) Ui AC 50/60 Hz
Impulse-withstand voltage (kV) Uimp
Rated operational voltage (V) Ue AC 50/60 Hz
DC
Rated operational voltage AC20 and DC20 (V) AC 50/60 Hz
Rated operational current (A) Ie Electrical AC 50/60 Hz
Interpact INS250 switch-disconnector 220-240 V
380-415 V
440-480 V (1)
500-525 V
056652_B
660-690 V
Electrical DC
125 V (2P in series)
250 V (4P in series)
Rated operational power AC23 (kW) Electrical AC 50/60 Hz
220-240 V
230 V (NEMA)
380-415 V
440 V
480 V (NEMA)
500-525 V
660-690 V
Interpact INS250 emergency-off switch-disconnector
Rated duties uninterrupted duty
intermittent duty
Short-circuit making capacity Icm min. (switch-disconnector alone)
(kA peak) max. (with upstream protection circuit breaker)
Short-time withstand current Icw (A rms) 1s
059487_B
3s
20 s
30 s
Suitability for isolation
Durability (category A) (O - C-O cycles) Mechanical
Electrical AC 50/60 Hz
440 V
500 V
690 V
Electrical DC
250 V
Positive contact indication
Visible break
Emergency-off switch disconnector
Degree of pollution
Interpact INS400 switch-disconnector
Upstream protection
See the “Additional characteristics” section, 308E5015
059488_B
24 Schneider Electric
Functions and Switch-disconnector selection (cont.)
characteristics Interpact INS250-100 to 630 (cont.)
– – – – – – – –
Schneider Electric 25
Functions and Switch-disconnector selection (cont.)
characteristics Interpact INS250-100 to 630 (cont.)
D W
26 Schneider Electric
Fonctions et Switch-disconnector selection (cont.)
caractéristiques Interpact INS250-100 to 630 (cont.)
b b b b b b b b
b b b b b b b b
– – – – – – – –
b b b b b b b b
b b b b b b b b
b b b b b b b b
b b b b b b b b
– – – – – – – –
b b b b b b b b
b b b b b b b b
– – – – b b b b
b b b b b b b b
b b b b b b b b
b b b b b b b b
b b b b b b b b
b b b b b b b b
b b b b b b b b
b b b b – – – –
b b b b – – – –
b b b b b b b b
b b b b b b b b
b b b b b b b b
b b b b b b b b
b b b b b b b b
5 < C < 6.2 5 < C < 6.2 5 < C < 6.2 5 < C < 6.2 13.5 < C < 16.5 13.5 < C < 16.5 13.5 < C < 16.5 13.5 < C < 16.5
b b b b b b b b
b b b b b b b b
b b b b b b b b
b b b b b b b b
b b b b – – – –
– – – – – – – –
b b b b b b b b
b b b b b b b b
b b b b b b b b
b b b b b b b b
15 15 15 15 50 50 50 50
140 x 136 x 86 140 x 136 x 86 140 x 136 x 86 140 x 136 x 86 185 x 205 x 120 185 x 205 x 120 185 x 205 x 120 185 x 205 x 120
140 x 136 x 86 140 x 136 x 86 140 x 136 x 86 140 x 136 x 86 185 x 205 x 120 185 x 205 x 120 185 x 205 x 120 185 x 205 x 120
2 2 2 2 4.6 4.6 4.6 4.6
2.2 2.2 2.2 2.2 4.9 4.9 4.9 4.9
300 x 400 x 200 300 x 400 x 200 300 x 400 x 200 300 x 400 x 200 400 x 600 x 200 400 x 600 x 200 400 x 600 x 200 400 x 600 x 200
Schneider Electric 27
Functions and Switch-disconnector selection (cont.)
characteristics Interpact INS630b to 2500
220-240 V
230 V (NEMA)
380-415 V
Nouvelle photo à venir 440 V
480 V (NEMA)
500-525 V
660-690 V
Rated duties uninterrupted duty
intermittent duty
Short-circuit making capacity Icm min. (switch-disconnector alone)
(kA peak) max. (with upstream protection circuit breaker)
Short-time withstand current Icw (A rms) 0.5 s
1s
3s
20 s
30 s
Suitability for isolation
Durability (category A) (O - C-O cycles) Mechanical
Interpact INS800 emergency-off switch-disconnector Electrical AC 50/60 Hz
220-240 V
380-415 V
440-480 V (1)
500-525 V
660-690 V
Electrical DC
125 V / 2 poles
250 V / 4 poles
Positive contact indication
Visible break
Emergency-off switch disconnector
Degree of pollution
Upstream protection
See the “Additional characteristics” section, 308E5025 and 308E5030
28 Schneider Electric
Functions and Switch-disconnector selection (cont.)
characteristics Interpact INS630b to 2500 (cont.)
– – – – – – –
Schneider Electric 29
Functions and Switch-disconnector selection (cont.)
characteristics Interpact INS630b to 2500 (cont.)
D W
30 Schneider Electric
Functions and Switch-disconnector selection (cont.)
characteristics Interpact INS630b to 2500 (cont.)
b b b b b b b
b b b b b b b
– – – – – – –
b b b b b b b
– – – – – – –
– – – – – b b
– – – – – – –
b b b b b – –
b b b b b b b
b b b b b – –
b b b b b – –
b b b b b b b
– – – – – – –
– – – – – – –
– – – – – – –
b b b b b b b
b b b b b b b
– – – – – – –
– – – – – – –
b b b b b b b
b b b b b b b
b b b b b b b
– – – – – – –
– – – – – – –
30 30 30 30 30 60 60
– – – – – – –
– – – – – – –
b b b b b b b
b b b b b b b
– – – – – – –
– – – – – – –
b b b b b b b
b b b b b b b
b b b b b b b
– – – – – – –
50 50 50 50 50 50 50
340 x 300 x 198 340 x 300 x 198 340 x 300 x 198 340 x 300 x 198 340 x 300 x 198 348 x 440 x 325 348 x 440 x 325
410 x 300 x 198 410 x 300 x 198 410 x 300 x 198 410 x 300 x 198 410 x 300 x 198 463 x 440 x 325 463 x 440 x 325
14 14 14 14 14 35 35
18 18 18 18 18 45 45
??? x ??? x ??? ??? x ??? x ??? ??? x ??? x ??? ??? x ??? x ??? ??? x ??? x ??? ??? x ??? x ??? ??? x ??? x ???
Schneider Electric 31
Functions and Switch-disconnector selection
characteristics Interpact INV100 to 630
Number of poles
Electrical characteristics as defined by IEC 60947-1 / 60947-3 and EN 60947-1 / 60947-3
Conventional thermal current (A) Ith at 60 °C
Conventional thermal current Ithe at 60 °C
in enclosure
Rated insulation level (V) Ui AC 50/60 Hz
Impulse-withstand voltage (kV) Uimp
Rated operational voltage (V) Ue AC 50/60 Hz
DC
Rated operational voltage AC20 and DC20 (V) AC 50/60 Hz
Rated operational current (A) Ie Electrical AC 50/60 Hz
220-240 V
380-415 V
440-480 V (1)
Interpact INV250 switch-disconnector
500-525 V
660-690 V
Electrical DC
125 V (2P in series)
250 V (4P in series)
056654_A
32 Schneider Electric
Functions and Switch-disconnector selection (cont.)
characteristics Interpact INV100 to 630 (cont.)
– – – – – – – –
Schneider Electric 33
Functions and Switch-disconnector selection (cont.)
characteristics Interpact INV100 to 630 (cont.)
D W
34 Schneider Electric
Functions and Switch-disconnector selection (cont.)
characteristics Interpact INV100 to 630 (cont.)
b b b b b b b b
b b b b b b b b
– – – – – – – –
b b b b b b b b
b b b b b b b b
b b b b b b b b
b b b b b b b b
– – – – – – – –
b b b b b b b b
b b b b b b b b
– – – – b b b b
b b b b b b b b
b b b b b b b b
b b b b b b b b
b b b b b b b b
b b b b b b b b
b b b b b b b b
b b b b – – – –
b b b b – – – –
b b b b b b b b
b b b b b b b b
b b b b b b b b
b b b b b b b b
– – – – – – – –
5 < C < 6.2 5 < C < 6.2 5 < C < 6.2 5 < C < 6.2 13.5 < C < 16.5 13.5 < C < 16.5 13.5 < C < 16.5 13.5 < C < 16.5
b b b b b b b b
b b b b b b b b
b b b b b b b b
b b b b b b b b
b b b b b b b b
– – – – – – – –
b b b b b b b b
b b b b b b b b
b b b b b b b b
b b b b b b b b
15 15 15 15 50 50 50 50
140 x 136 x 86 140 x 136 x 86 140 x 136 x 86 140 x 136 x 86 185 x 205 x 120 185 x 205 x 120 185 x 205 x 120 185 x 205 x 120
140 x 136 x 86 140 x 136 x 86 140 x 136 x 86 140 x 136 x 86 185 x 205 x 120 185 x 205 x 120 185 x 205 x 120 185 x 205 x 120
2 2 2 2 4.6 4.6 4.6 4.6
2.2 2.2 2.2 2.2 4.9 4.9 4.9 4.9
300 x 400 x 200 300 x 400 x 200 300 x 400 x 200 300 x 400 x 200 400 x 600 x 200 400 x 600 x 200 400 x 600 x 200 400 x 600 x 200
Schneider Electric 35
Functions and Switch-disconnector selection (cont.)
characteristics Interpact INV630b to 2500
E00000
230 V (NEMA)
380-415 V
440 V
Nouvelle photo à venir 480 V (NEMA)
500-525 V
660-690 V
Rated duties uninterrupted duty
intermittent duty
Short-circuit making capacity Icm min. (switch-disconnector alone)
(kA peak) max. (with upstream protection circuit breaker)
Short-time withstand current Icw (A rms) 0.5 s
1s
3s
20 s
30 s
Suitability for isolation
Durability (category A) (O - C-O cycles) Mechanical
Electrical AC 50/60 Hz
Interpact INV800 emergency-off switch-disconnector 220-240 V
380-415 V
440-480 V (1)
500-525 V
660-690 V
Electrical DC
125 V / 2 pôles
250 V / 4 pôles
Positive contact indication
Visible break
Emergency-off switch disconnector
Degree of pollution
Upstream protection
See the “Additional characteristics” section, 308E5025 and 308E5030
36 Schneider Electric
Functions and Switch-disconnector selection (cont.)
characteristics Interpact INV630b to 2500 (cont.)
– – – – – – –
Schneider Electric 37
Functions and Switch-disconnector selection (cont.)
characteristics Interpact INV630b to 2500 (cont.)
D W
38 Schneider Electric
Functions and Switch-disconnector selection (cont.)
characteristics Interpact INV630b to 2500 (cont.)
b b b b b b b
b b b b b b b
– – – – – – –
b b b b b b b
– – – – – – –
– – – – – b b
– – – – – – –
b b b b b – –
b b b b b b b
b b b b b – –
b b b b b – –
b b b b b b b
– – – – – – –
– – – – – – –
– – – – – – –
b b b b b b b
b b b b b b b
– – – – – – –
– – – – – – –
b b b b b b b
b b b b b b b
b b b b b b b
– – – – – – –
– – – – – – –
30 30 30 30 30 60 60
– – – – – – –
– – – – – – –
b b b b b b b
b b b b b b b
– – – – – – –
– – – – – – –
b b b b b b b
b b b b b b b
b b b b b b b
– – – – – – –
50 50 50 50 50 50 50
340 x 300 x 198 340 x 300 x 198 340 x 300 x 198 340 x 300 x 198 340 x 300 x 198 348 x 440 x 325 348 x 440 x 325
410 x 300 x 198 410 x 300 x 198 410 x 300 x 198 410 x 300 x 198 410 x 300 x 198 463 x 440 x 325 463 x 440 x 325
14 14 14 14 14 35 35
18 18 18 18 18 45 45
??? x ??? x ??? ??? x ??? x ??? ??? x ??? x ??? ??? x ??? x ??? ??? x ??? x ??? ??? x ??? x ??? ??? x ??? x ???
Schneider Electric 39
Functions and Complete source-changeover
characteristics assembly selection
Interpact INS250-100 to 630 (cont.)
E00000
40 Schneider Electric
Functions and Complete source-changeover
characteristics assembly selection (cont.)
Interpact INS250-100 to 630 (cont.)
– – – – – – – –
Schneider Electric 41
Functions and Complete source-changeover
characteristics assembly selection (cont.)
Interpact INS250-100 to 630 (cont.)
42 Schneider Electric
Functions and Complete source-changeover
characteristics assembly selection (cont.)
Interpact INS250-100 to 630 (cont.)
b b b b b b b b
b b b b b b b b
– – – – – – – –
b b b b b b b b
b b b b b b b b
b b b b b b b b
b b b b b b b b
– – – – – – – –
b b b b b b b b
b b b b b b b b
– – – – b b b b
b b b b b b b b
b b b b b b b b
b b b b b b b b
b b b b b b b b
b b b b b b b b
b b b b b b b b
– – – – – – – –
– – – – – – – –
b b b b b b b b
b b b b b b b b
b b b b b b b b
5 < C < 6.2 5 < C < 6.2 5 < C < 6.2 5 < C < 6.2 13.5 < C < 16.5 13.5 < C < 16.5 13.5 < C < 16.5 13.5 < C < 16.5
b b b b b b b b
b b b b b b b b
– – – – – – – –
b b b b b b b b
– – – – – – – –
– – – – – – – –
b b b b b b b b
b b b b b b b b
– – – – – – – –
b b b b b b b b
15 15 15 15 50 50 50 50
140 x 136 x 86 140 x 136 x 86 140 x 136 x 86 140 x 136 x 86 185 x 205 x 120 185 x 205 x 120 185 x 205 x 120 185 x 205 x 120
140 x 136 x 86 140 x 136 x 86 140 x 136 x 86 140 x 136 x 86 185 x 205 x 120 185 x 205 x 120 185 x 205 x 120 185 x 205 x 120
6.4 6.4 6.4 6.4 13.5 13.5 13.5 13.5
6.4 6.4 6.4 6.4 ??? ??? ??? 13.5
Schneider Electric 43
Functions and Installation
characteristics
052760_A
Individual enclosures
E56047_A
E90491
v a door with a cut-out
v a mounting plate
v accessories required for extended front or lateral
rotary handle
v removable plates (without holes) for cable entry.
The Interpact INS switch-disconnector must be order
separately.
Heavy-duty individual
enclosure (sheet metal or
plastic)
Interpact INS40 on a
symmetrical rail
Installation in a 300 mm
duct
44 Schneider Electric
Functions and Connection
E92189
characteristics Interpact INS40 to 160
Terminal shroud
Interphase
barrier Auxiliary contact
Extended lateral
control
Interpact Lateral control
INS40 to 160 on functional
enclosure
Lateral rotary
control
ON
I
ON
I
OFF
0
Emergency-off
Emergency-off Distribution OFF
0 extended rotary
connector control
1-cable Extended rotary
connector control
.1
.2
Interpact INS40 to INS80 switch-disconnectors are
equipped as standard with connectors for bare copper
.4
or aluminium cables.
E38888
Distribution connector
This connector screws directly into the switch-
disconnector terminals for connection of three cables
of the following types:
b 1 to 10 mm2 flexible cables (1)
b 1.5 to 16 mm2 rigid cables.
.1
Interpact INS100 to INS160 switch-disconnectors are
equipped as standard with terminals comprising nuts
with M6 screws for direct connection of insulated bars
E38889
N
or cables with lugs.
Lugs
The special lugs for copper cables may be used for Lug for copper cable
cables with cross-sectional areas up to 95 mm2.
Secure the lugs by hexagonal crimping or punching.
Lugs are supplied with interphase-barrier and are
compatible with the terminal shields.
E30707
.1
.2
.4
Schneider Electric 45
Functions and Electrical and mechanical
characteristics accessories
Interpact INS250
Interpact INV100 to 250
E72527
E72527
for spreaders
One-piece spreader
Interphase
I
barrier ON
Spreader
Handle I
ON
OFF
O Emergency-off
extended
Interpact Extended lateral rotary control
INS250 rotary control
Direct lateral
I
ON
rotary control
O
OFF
I
Locking by
O
ON keylock
OFF
Lateral rotary
control
Auxiliary
Visible break (INV) contacts
ON
I
OFF
0
Emergency-off
ON
I
extended rotary control
Current transformer
module OFF
0
I
ON
O
OFF
Escutcheon
Emergency-off
Ammeter module
16
A 12
8
4
0
160/5
Sealable short
terminal shield
Coupling accessory
46 Schneider Electric
Functions and Electrical and mechanical
characteristics accessories (cont.)
Interpact INS320 to 630
Interpact INV320 to 630
E92190
Sealable long
terminal shield
Bare cable
connectors
Edgewise
Right-angle teminal
terminal extension
Spreader extension
Interphase
barrier
Rear connections
Interpact
INS400 to 630
Locking
by keylock
Emergency-off
extended rotary
control
Extended rotary
control
Auxiliary
contacts
Ammeter module
Escutcheon
16
A 12
Emergency-off 4
8
0
160/5
Sealable short
terminal shield
Coupling accessory
Schneider Electric 47
Functions and Connection
characteristics Interpact INS250 to 630
Interpact INV100 to 630
E54456
E18600
Interpact INS250 to INS630 and INV100 to INV630
switch-disconnectors are equipped as standard with Right-angle terminal
E54459
E18601
ø5...8
spreaders) are available to solve all connection
problems. For Interpact INS/INV630 switch-
disconnectors, connection most often requires the
52.5 or 70 mm pitch spreaders.
Straight terminal extensions
Lugs for INS/INV250
Lugs are different for copper and aluminium cables.
They are supplied with interphase-barrier and are
compatible with the long terminal shields.
b the small lugs for copper cables may be used for
E21276
cables with the following cross-sectional areas:
v 120, 150 or 185 mm2 (INS/INV up to 250)
v 240 or 300 mm2 (INS/INV up to 630).
E54462
E54463
ø5...8
E30907
ø5...8
Spreaders
E54461
E54464
ø5...8
One-piece spreader
48 Schneider Electric
Functions and Connection (cont.)
characteristics Interpact INS250 to 630
Interpact INV100 to 630 (cont.)
E54457
E54468
Front connection of bare cables
Bare-cable connectors for Interpact INS/INV switch-
disconnectors may be used for both copper and
aluminium cables. 1-cable connector for
1-cable connectors for Interpact INS250 INS250 and INV100-250
and INV100 to 250
E54465
E54469
terminals or clip onto right-angle and straight terminal
extensions as well as spreaders.
ø5...8
1-cable and 2-cable connectors for Interpact
INS/INV320 to 630 1-cable connector
The connectors are screwed to device terminals or for INS/INV320 to 630
right-angle terminal extensions.
Distribution connectors for Interpact INS250
E54470
and INV100 to 250
These connectors are screwed directly to device
E54466
E54471
and INV100 to 250
The Polybloc connects directly to the device terminals
and is used to connect up to six or nine flexible or rigid
cables with cross-sectional areas not exceeding
10 mm2, to each pole. Connection is made to spring
terminals without screws.
Distribution connector for
INS250 and INV100 to 250
E54472
Rear connection
E54473
E54456
mounted on a backplate.
For the connection of cables without lugs, the 1-cable
connectors for Interpact INS250 and INV100 to 250
may be simply clipped onto the rear connections.
E54467
Four positions
Schneider Electric 49
Functions and Electrical and mechanical
characteristics accessories
Interpact INS630b to 2500
Interpact INV630b to 2500
E92191
Terminal shield
Interphase-barrier
Spreader
Vertical connection
adapter
Base for terminal shield
Interpact
INS800 to 1600
O
OFF
Locking
by keylock
Emergency-off
FO
FF
OF
extended
rotary control
d
trippe
ON
I
reset
OFF
0
d
trippe
ON
I
reset
OO
OFFF
OF
Escutcheon
Emergency-off (y 1600)
50 Schneider Electric
Functions and Connection
characteristics Interpact INS630b to 2500
Interpact INV630b to 2500
Direct connection
E88887
Bars
Interpact switch-disconnectors are equipped with
E88865 terminals and captive screws for direct connection
E88661
of bars.
E88663
disconnector for greater clearance between the bars.
They are not compatible with terminal shields.
E88867
Schneider Electric 51
Functions and Connection accessories
characteristics Distribution blocks
053997_A
Distribloc
3 outgoing
spring terminals
1 to 6 flexible or rigid
E54477
Mounting
on backplate 7 outgoing
spring terminals
1 to 4 flexible
or rigid
Clips onto
symmetrical
Distribloc 125 A rail
2 outgoing
spring terminals
1 to 10 flexible
1 to 16 rigid
E54475
1 incoming 1 outgoing
tunnel terminal 35 tunnel terminal 25
6 to 35 flexible 4 to 16 flexible Modular Circuit
10 to 50 rigid 4 to 25 rigid cover identification
N
52 Schneider Electric
Functions and Connection accessories (cont.)
characteristics One-piece spreader
E54200
056384_A
Pitch with 45 –
one-piece
spreader (mm)
Mounting
When equipped with a one-piece spreader, INS and INV
switch-disconnectors may be installed either at the back
of a switchboard or on the front panel with a front
alignment base.
b devices with different frame sizes can thus be
aligned in the switchboard
b the same mounting plate can be used for all devices
(including Compact NS circuit breakers).
Connection and insulation
accessories are identical to
E54548
E54541
Schneider Electric 53
Functions and Connection accessories (cont.)
characteristics Insulation of live parts
E54476
Terminal shields for INS and INV switch-
disconnectors
Lead-sealable insulation accessories used to protect
against direct contact with power circuits.
b degree of protection: IP40.5
b supplied with lead-sealing accessories.
056063_A
E54542
against direct contact with live connection screws. It is
also possible to attach an insulating plate (not
supplied) to the shrouds to avoid any contact with the
power conductors.
Interphase-barrier for
Interpact INS and INV
E54543
.1
.2
.4
Ø5
5 88
54 Schneider Electric
Functions and Auxiliary contacts
044314_A
characteristics
Standards
The auxiliary contacts comply with international standard IEC 60947-5.1.
Installation
ø5...8
They simply snap in under the auxiliaries cover (supplied as standard) of the
switch-disconnector.
Insulation
Sealable auxiliary shield to protect against direct contact with power circuits.
CAO Electrical characteristics of auxiliary contacts for Interpact INS and INV
or CAF Standard Low level
or OF
Interpact INS250 Rated thermal current (A) 6 5
and INV100 to 250 Minimum load 10 mA at 24 V 1 mA at 4 V
AC DC AC DC
Utilisation category AC12 AC15 DC12 DC14 AC12 AC15 DC12 DC14
(IEC 60947-5-1)
E54500
CAO or CAF
OF1 Interpact INS40 to 2500, INV100 to 2500
OF2
OF3 Possible combinations
Interpact INS/INV320 to 630 Interpact OF block CAM block (CAO or CAF)
INS40 to 160 2 or 2
INS250 2 or 2
INS400/630 3 and 1
INS630b/1600 3 and 1
E88715
INS2000/2500 3 and 1
OF1
CAO or CAF OF2
OF3
Interpact INS/INV800 to 1600
E88929
OF1
CAO or CAF OF2
OF3
Interpact INS/INV2000 to 2500
Schneider Electric 55
Functions and Current measurements
characteristics
Ammeter module
057355_A
Current-transformer module
For Interpact INS250 to 630 and INV100 to 630.
Function
Measure phase currents for display by an ammeter or a Digipact IM or PM module
(not supplied, see the corresponding catalogue).
Interpact INV250 with ammeter module
Installation
b connects directly to the downstream terminals of the switch-disconnector
b degree of protection: IP40.3
b class II insulation between front and power circuits
b connection via six built-in terminals for cables with a cross-sectional area
of 2.5 mm2.
Electrical characteristics
b current transformer with 5 A secondary winding
b accuracy class 3 for the following values of consumed output power:
v 100 A rating - 1.6 VA
v 150 A rating - 3 VA
v 250 A rating - 5 VA
v 400/630 A rating - 8 VA.
56 Schneider Electric
Functions and Rotary handle
characteristics
(1) The basic switch-disconnector must be the emergency-off (red and yellow) version
(2) Two models for universal enclosures and for Prisma G enclosures
(3) Emergency-off versions not available for INS/INV2000-2500.
E54501
.1
.2
.4
E54502
Makes it possible to operate the switch-disconnector,
installed inside a switchboard, from the front or side of
the switchboard. The extended rotary handle may be or
installed on the front or the side of the switch-
ø5...8
Schneider Electric 57
Functions and Coupling accessories
characteristics
E88932
Coupling accessory
This accessory simplifies connection of bars or cables with lugs when coupling two
Compact NS100 to 630 circuit breakers or two Interpact INS/INV100 to 630 switch-
disconnectors of the same size.
Pitch between outgoing terminals:
b Interpact INS250 and INV100 to 250: 35 mm
b Interpact INS/INV320 to 630: 52.5 mm
b Compact NS100 to 250: 35 mm
b Compact NS400 to 630: 52.5 mm.
58 Schneider Electric
Functions and Disabling device closing
characteristics
Padlocking
056649_A
b INS40 to 2500 A
b INV100 to 2500 A
b complete source-changeover assembly from 100 to 630 A.
Switch-disconnectors may be locked in the OFF position:
The handle is designed for locking by up to three padlocks (not supplied).
Locking in the OFF position guarantees isolation as defined by the IEC 60947-3
standard. The handle may also be lead-sealed in the OFF position.
.1
.2
E89551
.4
E32426
N
Keylocking
b INS250-100 to 2500 A
b INV100 to 2500 A
b complete source-changeover assembly from 100 to 630 A.
INS250 to 630, INV100 to 630 or INV1000 to 2500 switch-disconnectors may be
locked in the OFF position using a keylock (optional) that may be installed in the
hole prepared for that purpose on the front of the devices.
The key may not be removed when the switch-disconnector is in the ON position.
Keylocks can also be fitted on switch-disconnectors equipped with extended rotary
handles.
E89552
E54544
ø5...8
Schneider Electric 59
Functions and Switching to a replacement source
characteristics
position. The mechanism prevents simultaneous closing of the devices, but allows
them to be opened.
ø5...8
ø5...8
Possible combinations of “Normal” and “Replacement” source switch-disconnectors
rating “Normal” N “Replacement” R
Interpact INS (1)
40 INS40 INS40
63 INS63 INS63
80 INS80 INS80
100 INS100 b INS100
b b
125 INS125 b b b INS125
b b b b
160 INS160 b b b b b INS160
b b b b b b
b b b b
E88930
b
ON b b b b
I Interpact INS/INV (2) b b b
b b
ø5...8
60 Schneider Electric
Functions and Accessories
characteristics
Front-panel escutcheons
Escutcheons for switch-disconnectors and ammeter modules
Mounted on switchboard panel from the front using four screws.
E55275
E55276
ø5...8
160
A 120
80
40
0
160/5A
Identification labels
Interpact INS40 to 160 switch-disconnectors may receive Telemecanique
prefabricated labels, catalogue number AB1- (eight characters). Interpact INS250
to 630 and INV100 to 630 switch-disconnectors are supplied as standard with a
clip-on label for handwritten indications.
These devices also come with a nameplate into which a label can be inserted.
E18595
.P
DE P
P O
D E P. P O M push
to
trip
052760_A
Individual enclosures
Interpact INS and INV switch-disconnectors equipped with a front handle may be
installed in individual enclosures.
All fixed, front connections are possible, except right-angle and edgewise terminal
extensions. Spreaders may be installed in the enclosures intended for Interpact
INS250 to 630 and INV100 to 630 switch-disconnectors.
Heavy-duty metal individual enclosure for Interpact INS (IP557)
b metal enclosure
b door with keylock and cut-out for switch-disconnector rotary handle
b extended rotary front handle
b device mounting plate
b removable plate (without holes) for cable entry through bottom.
Heavy-duty insulating individual enclosure for Interpact INS and INV (IP557)
b metal enclosure
b transparent cover, screwed, lead sealable, with cut-out for switch-disconnector
rotary handle
b extended rotary front handle
b device mounting plate
b removable plates (without holes) for cable entry through bottom and/or top.
Dimensions
Metal enclosures WxHxD
Interpact INS40 to 160 350 x 350 x 250
Interpact INS250 350 x 450 x 250
Interpact INV100 to 250
Interpact INS320 to 630 350 x 650 x 250
Interpact INV320 to 630
Schneider Electric 61
62 Schneider Electric
Installation recommendations
Presentation 2
Functions and characteristics 17
Operating principle 64
Possible installation positions and mounting
techniques 66
Implementation 67
Interpact INS40 to 80 68
Interpact INS100 to 160 69
Interpact INS250-100 to 250, Interpact INV100 to 250 70
Complete source-changeover assembly
INS250-100 to 250
Interpact INS320 to 630, Interpact INV320 to 630 74
Complete source-changeover assembly
INS320 to 630
Connection 78
INS630b to 1600 and INV630b to 1600 78
INS2000 to 2500 and INV2000 to 2500 82
Use at high temperatures 84
Schneider Electric 63
Installation Operating principle
recommendations
INS250-100 to 250
INV100 to 250
OFF ON OFF
E94150
OFF ON OFF
OFF ON OFF
CAOF
INS320 to 630
INV320 to 630
OFF ON OFF
E94151
OFF ON OFF
OFF ON OFF
CAM
OFF ON OFF
OF
64 Schneider Electric
Installation Operating principle (cont.)
recommendations
INS630b to 2500
INV630b to 2500
OFF ON OFF
E90497
OFF ON OFF
OFF ON OFF
CAM
OFF ON OFF
OF
ON OFF ON
Schneider Electric 65
Installation Possible installation positions
recommendations and mounting techniques
E55416
E55417
E55418
ø5...8
ø5...8
ø5...8
ø5...8
E55419
E55420
ø5...8
Possible mounting
INS40 to 160
.1
.2
.1 .4
E55596
E55597
.2 .1
.4 .2
.4
E55421
N
N N
Ø5
5 88
Ø5
5 88 88
Ø5
5
E55416
E55422
INS/INV800 to 2500
E88863
E88862
66 Schneider Electric
Installation Implementation
recommendations
Reverse supply
Interpact switch-disconnectors may be supplied indifferently via the top or bottom
E55424
ø5...8
supported.
Note that the terminals of electrical devices (switch-disconnectors, contactors,
circuit breakers, etc.) should not be considered to contribute to the support of the
conductors.
Schneider Electric 67
Installation Interpact INS40 to 80
recommendations
E39432
.1
.2
.4
Front connection of bare copper and
N
aluminium cables
b Interpact INS40 to INS80 switch-disconnectors are equipped as standard with
E38888
(1) Connection of 1.5 to 4 mm2 flexible cables requires crimped or auto-crimping ferrules.
E88935
68 Schneider Electric
Installation Interpact INS100 to 160
recommendations
E30707
Front connection of bare copper and
E32424
aluminium cables
.1
.2
.4
E32423
E54545
are mandatory L S (mm2) 10 to 95 rigid 1.5 to 25 rigid
Cu / Al 10 to 95 flexible 1.5 to 16 flexible (1)
Torque (Nm) 10 3
Distribloc
S
Torque (Nm) Supply 5 Nm
Distribution 3 Nm
(1) Connection of 1.5 to 4 mm2 flexible cables requires crimped or auto-crimping ferrules.
Distribloc
.1
interphase-barrier or Lugs are supplied with interphase-barrier and are compatible with the terminal
long terminal shields shields.
are mandatory Bar Pole pitch
30 mm
Dimensions
Bars d (mm) y 10
E90303
e e (mm) 2…6.4
L (mm) y 21
Lugs L (mm) 15
Ø
ø (mm) u 6.2
Torque (Nm) 8
d
L L
Accessories
Interphase-barrier
b distribution blocks, lugs, right-angle/straight/edgewise terminal extensions and
spreaders are supplied with interphase-barrier
b interphase-barrier may be positioned horizontally or vertically
b they may be replaced by long terminal shields.
Interphase-barrier
Terminal shields
E88935
Terminal shrouds
Schneider Electric 69
Installation Interpact INS250-100 to 250
recommendations Interpact INV100 to 250
Complete source-changeover
assembly INS250-100 to 250
E54468
Front connection of bare copper and
aluminium cables
1-cable connector b 1-cable connectors snap directly on to the device terminals or are clipped on to
the right-angle or straight terminal extensions or spreaders.
E54465
L (mm) 15 ou 30
S S (mm2) Cu / Al 1.5…6 (1) 8...35
Torque (Nm) 4 6
Polybloc distribution block, 6 or 9 cables
L (mm) 12
S (mm2) Cu / Al 1.5…10
Polybloc distribution block
(1) Connection of 1.5 to 4 mm2 flexible cables requires crimped or auto-crimping ferrules.
Dimensions
E55426
1-cable connector
E55341
¯5...8 25,5 44
E55450
19
57,5 57,5
Z
X X
98,5
66,5
166
70 Schneider Electric
Installation Interpact INS250-100 to 250
recommendations Interpact INV100 to 250
Complete source-changeover
assembly INS250-100 to 250 (cont.)
E54463
Front connection of insulated bars and
cables with crimped lugs
Interpact INS250-100 to INS250 and INV100 to 250 switch-disconnectors are
E54459
equipped as standard with terminals receiving snap-in nuts and screws (M8 for
Small lugs for copper cables INS/INV up to 250, M10 from 320 upwards) for direct connection of insulated bars
or cables with lugs.
¯5...8
E30907
Lugs
Lugs are different for copper and aluminium cables. They are supplied with
If 500 V y U y 690 V, interphase-barrier and are compatible with the long terminal shields.
interphase-barrier or b the small lugs for copper cables may be used for cables with the following cross-
long terminal shields sectional areas:
are mandatory Small lugs for aluminium v 120, 150 or 185 mm2 (INS/INV up to 250)
cables Secure the lugs by hexagonal crimping or punching.
b the small lugs for aluminium cables may be used for cables with the following
cross-sectional areas:
v 150 or 185 mm2 (INS/INV up to 250)
E89683
L (mm) y 25
Ø (mm) u 10
Ø
Lugs L (mm) y 25
Ø (mm) u 10
d Torque (Nm) 15
L L
Dimensions
E55434
10,5
57,5
Z
X
E54476
Interphase-barrier
b distribution blocks, lugs, right-angle/straight/edgewise terminal extensions and
spreaders are supplied with interphase-barrier
b interphase-barrier may be positioned horizontally or vertically
b they may be replaced by long terminal shields.
¯5...8
Schneider Electric 71
Installation Interpact INS250-100 to 250
recommendations Interpact INV100 to 250
Complete source-changeover
assembly INS250-100 to 250 (cont.)
Front connection with accessories
Straight terminal Right-angle
E90490
E54460
extensions extensions
Material: tinned copper. Material: tinned copper
Installation on upstream
¯5...8
terminals
E18601
Connection of two
cables with lugs
E18600
If 500 V y U y 690 V, Insulation stripping lengths and tightening torques for cables, bare bars and cables
interphase-barrier or with lugs are identical to those for direct connection to devices.
long terminal shields
are mandatory Spreader
Material: tinned copper.
E90490
E18599
E55599
Separate parts Connection of two cables One-piece spreader
with lugs
Pole pitch
45 mm
Dimensions
Bars L (mm) y 25
E50303
e d (mm) y 10
e (mm) y6
Ø (mm) 8.5
Ø
Cosses L (mm) y 25
Ø (mm) 8.5
d Torque (Nm) 15 (1)
L L
Dimensions
Right-angle terminal extensions Spreader and straight terminal extensions
39,5 4 114 159
E55436
45 45 45 45 45 19,5
20,5
30
E55440
98,5
57,5
Z
X X
17,5
Y Y Z
One-piece spreader 3P/4P
180,5 Z
45 45 45 98 Z 98
E55342
43,5
125,5
Y
24
72 Schneider Electric
Installation Interpact INS250-100 to 250
recommendations Interpact INV100 to 250
Complete source-changeover
assembly INS250-100 to 250 (cont.)
Rear connection
E25967
E55446
E90303
e d (mm) y 10
If 500 V y U y 690 V, e (mm) y6
E89683
L L
Dimensions
E55447
10
Two lenghts ∅8,6 ∅20
13
18
57,5
43 short RC
88 long RC X
E54474
Four positions
Schneider Electric 73
Installation Interpact INS320 to 630
recommendations Interpact INV320 to 630
Complete source-changeover
assembly INS320 to 630
E54469
Front connection of bare copper and
aluminium cables
E55428
1-cable connector 1-cable and 2-cable connectors, made of tinned aluminium for copper and
aluminium cables, are screwed to the device terminals or to right-angle terminal
extensions. These connectors are supplied with interphase-barrier.
E54470
1-cable 2-cable
connector connector
Torque (Nm) 31 31
E54545
L
2-cable connector
S
If 500 V y U y 690 V,
Dimensions
interphase-barrier or
long terminal shields 1-cable connector
are mandatory
49 44 Z
Z
E55429
E55431
14
88,5 88,5
X
X
2-cable connector
Z
46,5
E55430
88,5
X
Interphase-barrier
b distribution blocks, lugs, right-angle/straight/edgewise terminal extensions and
spreaders are supplied with interphase-barrier
E88874
74 Schneider Electric
Installation Interpact INS320 to 630
recommendations Interpact INV320 to 630
Complete source-changeover
assembly INS320 to 630 (cont.)
E54463
Front connection of bars and cables with
crimped lugs
Interpact INS320 à 630 et INV320 à 630 switch-disconnectors are equipped as
E88872
standard with terminals receiving snap-in nuts and screws (INS/INV from 320 :
Small lugs for copper cables M10) for direct connection of bars or cables with lugs.
Lugs
E30907
Lugs are different for copper and aluminium cables. They are supplied with
interphase-barrier and are compatible with the long terminal shields.
b the small lugs for copper cables may be used for cables with the following cross-
sectional areas:
If 500 V y U y 690 V, v 240 or 300 mm2 (INS/INV up to 630).
interphase-barrier or Small lugs for aluminium Secure the lugs by hexagonal crimping or punching.
long terminal shields cables b the small lugs for aluminium cables may be used for cables with the following
are mandatory cross-sectional areas:
v 240 or 300 mm2 (INS/INV up to 630).
Secure the lugs by hexagonal crimping.
E89683
Pole pitch
45 mm
Dimensions
Bar
Bars d (mm) y 15
E90303
e e (mm) 3 y e y 10
L (mm) y 32
Ø (mm) u 10
Ø Lugs L (mm) y 32
Ø (mm) u 10
d Torque (Nm) 50
L L
Dimensions
INS320 to 630 - INV320 to 630
Z
E55433
14
88,5
Schneider Electric 75
Installation Interpact INS320 to 630
recommendations Interpact INV320 to 630
Complete source-changeover
assembly INS320 to 630 (cont.)
Front connection with accessories
E89683
Spreader Straight terminal Right-angle
Bar extensions terminal extensions
Material: tinned copper. Material: tinned copper. Material: tinned copper.
E88873
Installation on upstream
terminals
E88876
E88877
E88875
If 500 V y U y 690 V,
Pole pitch
interphase-barrier or
Without spreader 45 mm
long terminal shields
With spreader 52.5 or 70 mm
are mandatory
Dimensions with with edgewise
spreader terminal ext.
Bars L (mm) y 40 y 32
E90303
e d (mm) y 20 y 15
e (mm) 3 y e y 10 3 y e y 10
Ø (mm) 12.5 > 10.5
Ø
Lugs L (mm) y 40 y 32
Ø (mm) 12.5 10.5
d Torque (Nm) 50 (1) 50 (1)
L L
Dimensions
Edgewise terminal extensions Right-angle terminal extensions
F vue F
E55444
61 8
E55438
Z
58 Z
42
34
8
88,5 88,5
X X
Spreader
K10 K9
E55442
K8 K8 K8 K8 K8 26
39
108
22,5
Y Y Z
Type K8 K9 K10
Spreader width in mod. of 52.5 mm 52.5 187.5 135
width in mod. of 70 mm 70 240 170
76 Schneider Electric
Installation Interpact INS320 to 630
recommendations Interpact INV320 to 630
Complete source-changeover
assembly INS320 to 630 (cont.)
E25967
Rear connection of bars or cables with
E88870
crimped lugs
Interpact INS320 to 630 and INV320 to 630 switch-disconnectors may be equipped
with long or short rear connections, or a mix of the two. The connections may be
positioned flat, on edge or at 45° angles, or any combination thereof.
Connection of bars or cables Material of rear connections: tinned copper.
with lugs
Dimensions
Bars L (mm) y 32
E90303
e d (mm) y 15
E88879
L L
Dimensions
Four positions INS320 to 630 - INV320 to 630
E55447
E55449
10 15 ∅13 ∅23,2
∅8,6 ∅20
E89683
13 14
18 30
Bar 57,5
43 short RC 50 short RC 88,5
88 long RC X 115 long RC X
Z Z
6 8
the rear connections may be equipped with 1-cable connectors secured by clips.
Insulation stripping lengths and tightening torques for cables are identical to those
for direct connection to devices.
If 500 V y U y 690 V,
short terminal shields
are mandatory
Schneider Electric 77
Installation Connection
recommendations INS630b to 1600 and
INV630b to 1600
of bars.
E88888
E88889
2 Ø12 maxi 3 Ø12 maxi
12,5 12,5
25
25 25
12,5 50 80
15
E88682
E88866
78 Schneider Electric
Installation Connection (cont.)
recommendations INS630b to 1600 and
INV630b to 1600 (cont.)
Connections
There are many solutions to connect bars:
E88666
b vertical connection adapters to connect edgewise bars
b spreaders with a 95 mm pole pitch to increase the clearance between bars.
E88868
Spreaders
E88867
E89547
E88668
Schneider Electric 79
Installation Connection (cont.)
recommendations INS630b to 1600 and
INV630b to 1600 (cont.)
Dimensions
Connection with spreaders
97,5 95 95 95
110 95 95 70 70 70
70 70
12,5 12,5
202 202
E88669
E88671
E88670
187 187
X X
X
187 187
202 202
Y
56,5 15
Spreader details
77 77 77 77
38,5 38,5 38,5 38,5
13,5 13,5 13,5 13,5
25 = = 25 = = 25 = = 25 = =
E89548
E89550
E88672
E89549
30 30 30 30
82 52 82 52 82 52 82 52 15
15 15 15
5 Ø11 5 Ø11 5 Ø11
25 25 25 25
52 52 52 52
For 3P switch-disconnectors For 4P switch-disconnectors
221
E88674
E88675
206
171
X X
X
171
206
221
Y Y
50,5 12
Connector details
89 12,5
25 = = 15
E88676
13
Note: 101 21
2 connection possibilities on vertical connection adapters
(21 mm between centres)
Recommended connection screws: M10 class 8.8. 15 17
Tightening torque: 50 Nm with contact washer.
80 Schneider Electric
Installation Connection (cont.)
recommendations INS630b to 1600 and
INV630b to 1600 (cont.)
256
E88678
E88679
206
191
X X
X
191
206
256
Y Y
155 12
Cable lug adapter detail
184
50 50 50 17
15
E88680
80 50
5 Ø13 5 Ø11
Schneider Electric 81
Installation Connection (cont.)
recommendations INS2000 to 2500 and
INV2000 to 2500
E88888
E88889
2 Ø12 maxi 3 Ø12 maxi
12,5 12,5
25
25 25
12,5 50 80
15
82 Schneider Electric
Installation Connection (cont.)
recommendations INS2000 to 2500 and
INV2000 to 2500 (cont.)
Dimensions
Connection with spreaders
347,5 462,5
67,5 115 115 67,5 115 115 115
90 90
E94154
205
E94152
E94153
205
270 270
X X 440 X
440
180 180
205 205
Y Y
76 24
Spreader details
E94155
E94156
E94157
E94158
Schneider Electric 83
Installation Use at high temperatures
recommendations
Temperature derating
Interpact INS 40 63 80 100 125 160
Front connection with bare-cable connectors or lugs
Thermal current Ith at 60 °C 40 63 80 100 125 160
65 °C 40 63 80 100 125 160
70 °C 40 63 80 100 125 150
Interpact INS/INV 100 160 200 250 320 400 500 630
Front connection / rear connection
Thermal current Ith at 60 °C 100 160 200 250 320 400 500 630
65 °C 100 160 200 250 320 400 500 590
70 °C 100 160 200 250 320 400 500 550
Front connection with right-angle terminal extension + bare-cable connectors
Thermal current Ith at 55 °C 100 160 200 250 320 400 500 630
60 °C 100 160 200 250 320 400 500 590
65 °C 100 160 200 250 320 400 500 550
70 °C 100 160 200 240 320 400 500 510
Front connection / rear connection with ammeter or CT module
Thermal current Ith at 40 °C 100 160 200 250 320 400 500 600
50 °C 100 160 200 250 320 400 500 575
55 °C 100 160 200 250 320 400 500 540
60 °C 100 160 200 240 320 400 500 505
65 °C 100 160 200 230 320 400 480 480
70 °C 100 160 200 210 320 400 450 450
Interpact INS/INV 630b 800 1000 1250 1600 (4 bars 50 x 5) 2000 2500
with or without with or without with without with without without without
term. shield term. shield term. shield term. shield term. shield term. shield term. shield term. shield
Direct connection by flat-facing bars
Thermal current Ith at 40 °C 630 800 1000 1250 1250 1600 1600 2000 2500
45 °C 630 800 1000 1250 1250 1570 1600 2000 2500
50 °C 630 800 1000 1250 1250 1500 1550 2000 2500
55 °C 630 800 1000 1250 1250 1420 1470 2000 2500
60 °C 630 800 1000 1250 1250 1340 1390 2000 2500
65 °C 630 800 1000 1250 1250 1250 1300 2000 2500
70 °C 630 800 1000 1060 1210 1060 1210 2000 2400
Interpact INS/INV 630b 800 1000 1250 1600 (3 bars 80 x 5)
Connection by flat-facing bars via spreaders, WITHOUT terminal shields
Thermal current Ith at 40 °C 630 800 1000 1250 1600
45 °C 630 800 1000 1250 1600
50 °C 630 800 1000 1250 1580
55 °C 630 800 1000 1250 1500
60 °C 630 800 1000 1250 1420
65 °C 630 800 1000 1250 1330
70 °C 630 800 1000 1240 1240
Interpact INS/INV 630b 800 1000 1250 1600
with without
term. shield term. shield
Connection of edgewise bars via vertical connection adapters or cables via vertical connection adapters with cable-lug adapters
Thermal current Ith at 40 °C 630 800 1000 1250 1600 1600
45 °C 630 800 1000 1250 1600 1600
50 °C 630 800 1000 1250 1600 1600
55 °C 630 800 1000 1250 1600 1600
60 °C 630 800 1000 1250 1600 1600
65 °C 630 800 1000 1250 1520 1560
70 °C 630 800 1000 1250 1410 1450
Thermal current Ith in Amps (QA)
84 Schneider Electric
Dimensions and connection
Presentation 2
Functions and characteristics 17
Installation recommendations 63
Schneider Electric 85
Dimensions Interpact INS40 to 160
and connection
Dimensions
Front handle
E32250
E32252
(a)
(b) Y
K
E32255
H3 H7
P5 X X X
H1 H5
H
H2 H4 H6
120°
P
K1 K1 K1
P1
L K
P2 (a) Terminal shields INS40/63/80
L1
P3 (b) Terminal shields INS100/125/160
L2
P4
Z
Dimensions (mm)
Type H H1 H2 H3 H4 H5 H6 H7 K K1 L L1 L2 P P1 P2 P3 P4 P5
INS40/63/80 22.5 45 40.5 81 42.5 85 73.5 147 1 18 46 73 90 21.3 43 47 62.5 79 5
INS100/125/160 22.5 45 50 100 50 100 110 220 7.5 30 67.5 119 135 18.5 45 47 62.5 79 5
Dimensions (mm)
E32609
X Type e K Length
of shaft
INS40/63/80 1…3 1 A – 69
INS100/125/160 1…3 7.5 A – 69
Z
B 47
A
Dimensions (mm)
Type C R K
E32261
INS40/63/80 47 92 1
E32611
=
X
C
=
Y
= =
R
86 Schneider Electric
Dimensions Interpact INS40 to 160 (cont.)
and connection
Dimensions
Standard lateral handle
E32253
E32254
E32256
X X 120°
60°
Dimensions (mm)
Z Y
P6 Type L3 P6 P7
P7 L3 INS40/63/80 109 40 66.1
INS100/125/160 154 42.5 69.3
65
32,5
e
E32613
I
75
X
120°
X
O 37,5
Y
B 33
Z
P6
Dimensions (mm)
Type B e P6 Length
With shaft mini maxi of shaft
INS40/63/80 155 396 1…3 40 B – 95
INS100/125/160 200 441 1…3 42.5 B – 140
Without shaft B e P6
INS40/63/80 102 1…3 40
INS100/125/160 147 1…3 42.5
65
E38890
32,5
e
E38891
I
75
120° X
X
O 37,5
Y
B 33
Z
P6
Dimensions (mm)
Type Enclosure Type B e P6
Note: length of shaft
Lines X and Y indicate the axes of symmetry of the INS40/63/80 550 mm short 149 1…3 41.5
switch-disconnector. 600 mm long 174 1…3 41.5
Reference plane Z corresponds to the back of the switch- INS100/125/160 550 mm short 194 1…3 41.5
disconnector. 600 mm long 219 1…3 41.5
Schneider Electric 87
Dimensions Interpact INS40 to 160 (cont.)
and connection
Dimensions (cont.)
Front panel cutout for extended handle
E38892
Ø6
Ø50
55°
R = 36 Z
23,4 23,4
P6
Installation
On a backplate sur rail symétrique
On rail
ØT
E32259
E32452
C2
X
C1
Dimensions (mm)
Y Type C1 C2 R1 R2 ØT U
R1
INS40/63/80 40 80 10 36 4.5 35
R2
INS100/125/160 37.5 75 22.5 60 4.5 35
88 Schneider Electric
Schneider Electric 89
Dimensions Interpact INS250-100 to 630
and connection Interpact INV100 to 630
Dimensions
Front handle
E51177
E51178
(a)
(b)
E51179
H3 H5 H7
X X H8
H1
H
H2 H4 H6
Dimensions (mm)
Type H H1 H2 H3 H4 H5 H6 H7 H8 H11 K K1 L L1 P P1 P2 P3 P4
INS250 40 80 68 136 148 296 166 332 115 57.5 17.5 35 70 140 21.5 86 96 131 138
INV100/250
INS320/630 61.5 123 102.5 205 215 430 – – 177 88.5 22.5 45 92.5 185 26 120 130 160.4 162
INV320/630
Type A e
mini maxi
E54514
E54508
=
X X
H9 C7
=
C6
Y Y
L3 R6
L4 R7
Dimensions (mm)
Type C6 C7 H9 L3 L4 R6 R7
INS250 51.5 103 82 65.5 131 81 162
INS320/630 76.5 153 127 85.5 171 101 202
90 Schneider Electric
Dimensions Interpact INS250-100 to 630
and connection Interpact INV100 to 630 (cont.)
Dimensions
Standard lateral handle for INS250-100 to 250 and INV100 to 250
91
E56574
E56573
X 100
50
203
1...3
E56576
E56575
Y
152,5 mini 48
577 maxi
Installation
On panel fixed/FC On panel fixed/RC On rail
Ø5 K1 K1 K1
L6
L5
E90472
E51183
E90473
H11
X X X H11
H8
H10 H11 H10
Y
Y
Note:
Y Lines X and Y indicate the axes of symmetry of the
L5 switch-disconnector.
L6 Reference plane Z corresponds to the back of the switch-
disconnector.
Schneider Electric 91
Dimensions Interpact INS250-100 to 630
and connection Interpact INV100 to 630 (cont.)
Dimensions
Switch-disconnector with ammeter module Switch-disconnector equipped
Direct handle (*) Extended handle with current transformer
E90475
E90474
E94201
X X X
H8 H10 H12
P1 P1
P2 P2
P1 P47 P3 (1)
P2 Z P4 (2)
P47 Z
Z
(*) Only for INS250/INV100 to 250. (1) To front of direct handle.
(2) To front of key.
C23
X X X
C22
C28
C29
C27 (*)
C27
Y
Z 185 y A y 600 R16
R17
R14
Z P43
R15
Note:
lines X and Y indicate the axes of symmetry of the switch-
disconnector.
Reference plane Z corresponds to the back of the switch-
disconnector.
92 Schneider Electric
Dimensions Interpact INS250-100 to 630
and connection Interpact INV100 to 630 (cont.)
E90478
E90479
E21521
U(e)
X X X
G1 G1
G7 G G9 G G7
G6 G8 G6
ØT
Y
Y Y
E94257
U(e)
X X X G1
G1
G G G11
G13
G11
G10 G10
G12
ØT
Y Y
Y
Dimensions (mm)
Type C22 C23 C27 C28 C29 G G1 G6 G7 G8 G9 G10 G11 G12 G13
INS/INV100 to 250 41 82 56.5 187 ?? 62.5 125 137.5 200 145 215 ?? ?? ?? ??
INS/INV320 to 630 63.5 127 56.5 162 ?? 100 200 200 300 213.5 327 ?? ?? ?? ??
Type H8 H9 H10 H11 H12 H13 H14 H15 H16 H17 H18 H19
INS/INV100 to 250 216 282 231.5 ?? ?? ?? ?? ?? ?? ?? ?? ??
INS/INV320 to 630 202.5 305 217.5 ?? ?? ?? ?? ?? ?? ?? ?? ??
Schneider Electric 93
Dimensions Interpact INS630b to 1600
and connection Interpact INV630b to 1600
Dimensions
Direct front handle
3 poles 4 poles
(a)
E88687
(b) (a)
(b)
260,5
247
E88689
E88688
270
185 X 270 X
270 300
X
117,5
150
247
Y Y
260,5
70 70 70 70 70
56,5 105 20 175 20
105,5 210 280
140,5 340 410
146,5
(a) Terminal shields
198 (b) Interphase-barrier
Z
Dimensions (mm)
Type A e K Length
mini maxi of shaft A
E88693
30° R100
X X
H1
H
30°
Y
K Z
Note:
Lines X and Y indicate the axes of symmetry of the
switch-disconnector.
Reference plane Z corresponds to the back of the switch-
disconnector.
94 Schneider Electric
Dimensions Interpact INS630b to 1600
and connection Interpact INV630b to 1600 (cont.)
B
A
E90471
E88694
X
G
X
F
Z Y
E
C
D
Installation
On backplate On rail
E88884
E88690
Ø9
X X
180 180
90 90
Y
115 (3P)
Y 185 (4P)
115 (3P) 320 (3P)
185 (4P) 390 (4P)
320 (3P)
390 (4P)
Schneider Electric 95
Dimensions Interpact INS2000 to 2500
and connection Interpact INV2000 to 2500
Dimensions
Direct front handle
3 poles 4 poles
177,5 247,5
E94161
E94162
E94160
X X 410 X 410
210 440
185 235
Y Y
186,5 17,5 390 62,5
221,5 177,5 132,5 51 462,5
227,5 51 347,5
320
96 Schneider Electric
Dimensions Interpact INS2000 to 2500
and connection Interpact INV2000 to 2500 (cont.)
E90471
X
G
Y
E
e
4P 188 369 173 108 216
Installation
On backplate
E88690
Ø9
X
180
90
Y
115 (3P)
185 (4P)
320 (3P)
390 (4P)
Schneider Electric 97
Dimensions Mechanical interlocks for direct
and connection and extended handles
(INS40 to 630, INV100 to 630)
E54511
P
X Q X
D
Y Y
E B
G A
Z
INV100/250
INS320/630 416 115 100 200 92.5 210 22.5 386 100 175 74.5 130 102.5 205
INV320/630
N
X
M
Y Y
H H
F L
K
E55451
X Q X
D
Y Y
E B
G 47
Z A
Dimensions (mm)
Door cutout for extended handle
Type A B C D E F G H P Q
H H mini maxi
INS40/80 325 90 87.5 175 46 156 155 396 0 45 90
INS100/160 325 90 87.5 175 70 156 200 441 0 50 100
E55453
98 Schneider Electric
Dimensions Complete source changeover
and connection assembly
INS250-100 to 250 A
and INS320 to 630
Dimensions of the complete source-changeover assembly with a direct handle
E68354
Y Y
E68355
D
E
X
A
B
C
I
J
X
Y Y
G K
H
E90486
Y Y
F
X
G H
X
C
A D
B E
Z
Dimensions (mm)
Door cutout
Type A B C D E F G H I J
E90487
Y Y
I
J
Schneider Electric 99 99
Dimensions Installation of downstream
and connection coupling
(INS250-100 to 630, INV100 to 630)
Dimensions
Y Y
E55455
E55454
X X
L38 L37
Dimensions Connection
E55456
Y Y
L28 Y Y
L29
L30 K4
E55458
L31 K1 K1 K1 K3 K1 K1 K1
X X
L35
E55457
L36
G2 G29 G52 K8
G30 K9
G3
G28 K16
K2 K2 K2
L32
L39
L33
L34
L40
Dimensions (mm)
Type G2 G3 G28 G29 G30 G52 K1 K2 K3 K4 K8 K9 K16
INS250 105.5 169 225.2 83.5 127.5 143.5 35 35 51 156 57.5 157.5 25.4
INV100/250
INS320/630 141 240.7 315 118.4 163.4 202.5 45 52.5 75 210 88.5 225.7 26.1
INV320/630
Type L28 L29 L30 L31 L32 L33 L34 L35 L36 L37 L38 L39 L40
INS250 320 82.2 300 72.2 16.4 123 139.5 74.5 19.5 70 21.5 24.9 140
INV100/250
INS320/630 420 105.2 400 95.2 11.1 187.5 184.7 96.5 24 92.5 26 22.4 210
INV320/630
Front-panel escutcheon
For switch-disconnectors
E56502
E56501
E56500
M6 M7
A2 D1 D2
Dimensions (mm)
Type A2 D1 D2 M6 M7
INS250 174 3.5 6.5 114 101
INV100/250
INS320/630 215.5 3.5 6.5 164 151
INV320/630
INS630b/2500 3P 346 3.5 11.5 257.5 242 x 326.5
INV630b/2500 4P 416 3.5 11.5 257.5 242 x 396.5
E21652
E21650
93,5 80,5
E94165
ø5...8
Presentation 2
Functions and characteristics 17
Installation recommendations 63
Dimensions and connection 85
Upstream protection
By circuit breaker type / max. rating (A)
380/415 V Isc max. kA rms
making capacity kA peak
type / max. rating (A)
Isc max. kA rms
making capacity kA peak
type / max. rating (A)
Isc max. kA rms
making capacity kA peak
type / max. rating (A)
Isc max. kA rms
making capacity kA peak
type / max. rating (A)
Isc max. kA rms
making capacity kA peak
type / max. rating (A)
Isc max. kA rms
ø5...8
alarm
90 %Ir
105
making capacity kA peak 154 154
23 SE
STR
Upstream protection
By circuit breaker Compact NS
By circuit breaker type / max. rating (A)
380/415 V Isc max. kA rms.
making capacity kA peak
type / max. rating (A)
Isc max. kA rms.
making capacity kA peak
type / max. rating (A)
Isc max. kA rms.
making capacity kA peak
By circuit breaker type / max. rating (A)
440/480 V (*) Isc max. kA rms.
making capacity kA peak
type / max. rating (A)
Isc max. kA rms.
making capacity kA peak
type / max. rating (A)
Isc max. kA rms.
making capacity kA peak
By circuit breaker type / max. rating (A)
500 V/525 V Isc max. kA rms.
making capacity kA peak
type / max. rating (A)
Isc max. kA rms.
making capacity kA peak
type / max. rating (A)
Isc max. kA rms.
making capacity kA peak
By circuit breaker type / max. rating (A)
690 V Isc max. kA rms.
making capacity kA peak
type / max. rating (A)
Isc max. kA rms.
making capacity kA peak
type / max. rating (A)
Isc max. kA rms.
making capacity kA peak
By fuse
By fuse Type aM (1) / max. rating (A)
500V Isc max. kA rms.
making capacity kA peak
Type gG (2) / max. rating (A)
Isc max. kA rms.
making capacity kA peak
Type gG (1) / max. rating (A)
Isc max. kA rms.
making capacity kA peak
Type BS (2) / max. rating (A)
Isc max. kA rms.
making capacity kA peak
Type BS (1) / max. rating (A)
Isc max. kA rms.
making capacity kA peak
Presentation 2
Functions and characteristics 17
Installation recommandations 63
Dimensions and connection 85
Additional characteristics 103
3P 4P
Interpact INS100 28908 28909
E33366
3P 4P
Interpact INS100 28924 28925
E33366
Individual enclosures
IP55 heavy-duty sheetmetal enclosure
For INS40 to INS160 with extended standard rotary handle 31208
For INS40 to INS160 with extended red handle on yellow front 31209
E90492
Connection accessories
Distribloc distribution block (for bare cables)
INS40 to 125 125 A, 12 outgoing spring terminals (7 x 4 mm2 + 3 x 6 mm2 (2) 07105
+ 2 x 10 mm2) + 1 outgoing tunnel terminal (25 mm2)
E33404
INS100 to 160 160 A, 12 outgoing spring terminals (7 x 4 mm2 + 3 x 6 mm2 (2) 07106
+ 2 x 10 mm2) + 1 outgoing tunnel terminal (25 mm2) with
prefabricated connections
Multi-stage distribution block (for bare cables)
INS40 to 125 125 A, 4 x 10 holes (5 x 10 mm2 + 4 x 16 mm2 + 1 x 35 mm2) (2) 13512
INS40 to 125 125 A, 4 x 17 holes (8 x 10 mm2 + 8 x 16 mm2 + 1 x 35 mm2) (2) 13514
E26801
Terminal shrouds
INS40 to 80 3P/4P Set of 2 28955
INS100 to 160 3P/4P Set of 2 28956
E24075
Terminal shields
INS40 to 80 3P/4P Set of 2 28957
INS100 to 160 3P/4P Set of 2 28958
E32457
Interphase barriers
INS100 to 160 3P/4P Set of 6 28959
E88893
Rotary handles
Accessories for conversion to extended rotary handles
Front control Black handle INS40 to 160 28941
Red handle INS40 to 160 28942
E33405
on yellow front
Lateral control Black handle INS40 to 160 28943
Red handle on yellow front (1) INS40 to 160 28944
Lateral control on G, GX or Black handle INS40 to 160 28945
E51011
Ø5
5 88
¿5...8
Spare parts
.1
.2
Black handle 28962
Red handle (1) 28963
E32411
N .4
or
3P 4P
Interpact INS320 31108 31109
E50996
3P 4P
Interpact INS320 31128 31129
E50996
3P 4P
Interpact INV320 31168 31169
E51002
3P 4P
Interpact INV320 31188 31189
E51002
Individual enclosures
IP55 heavy-duty insulating enclosure
For INV100 to 250 with extended standard rotary handle 31204
For INV100 to 250 with extended red rotary handle on yellow front 31205
E32419
Front alignment base for INV320 to 630 combination with NS250 31064
INV320 to 630 combination with NS400/630 31068
¿5...8
Flexible connection assembly for vertical INV100 to 250 with horizontal NS250 31069
Flexible connection assembly for vertical INV320 to 630 with horizontal NS250 31092
E89641
Flexible connection assembly for vertical INV100 to 250 with vertical NS250 beside 31071
Flexible connection assembly for vertical INV320 to 630 with vertical NS400/630 beside 31072
Flexible connection assembly for vertical INV320 to 630 with vertical NS250 beside 31093
Connection accessories
Rear connections
Short (1 pair) 29235
Long (1 pair) 29236
E18579
Distribution connector for six 1.5 to 35 mm2 cables with Set of 3 29248
interphase barriers Set of 4 29249
* consult us
Set of 4 29262
Straight terminal extensions Set of 3 29263
E18601
Set of 4 29264
piece spreader
Crimp lugs for copper cables (supplied with 2 or 3 interphase barriers)
For 120 mm2 cables Set of 3 29252
Set of 4 29256
E18602
Terminal shields
Short 3/4 P Set of 2 29322
Long 3/4 P Set of 2 29324
E51007
Interphase barriers
Set of 6 29329
E18606
16
A 12
8
150 30556
0
160/5
250 31566
Current transformer module (4P)
Rating (A) 100 29458
150 30558
E51009
250 31568
Rotary handles
Extended front control
For INS250 with standard rotary handle 31050
For INS250 with red handle on yellow front (1) 31051
E33405
fl
fl
+ Ronis 1351B.500 keylock 41940
or + Profalux KS5 B24 D4Z keylock 42888
¿5...8
¿5...8
+ Ronis 1351B.500 keylock (2 keylocks / 1 key) 41950
¿5...8
Installation accessories
Front panel escutcheons
For INS/INV 31079
For ammeter module, IP40 29318
E18591
Connection accessories
Rear connections
Short (1 pair) 32475
Long (1 pair) 32476
E18579
Set of 4 32480
For 2 cables, 35 mm2 to 240 mm2 Set of 3 32481
E22041
Set of 4 32482
Tab connector for voltage tap on bare cable connector Set of 2 29348
Set of 4 32485
70 mm 3P 32492
4P 32493
Crimp lugs for copper cables (supplied with 2 or 3 interphase barriers)
For 240 mm2 cables Set of 3 32500
Set of 4 32501
E18602
Terminal shields
Short 3/4P Set of 2 32563
Long 3/4P Set of 2 32565
E51007
Long for 52.5 mm spreader (supplied with insulating plate) 3/4P Set of 2 32583
Interphase barriers
Set of 6 32570
E89622
Electrical auxiliaries
Auxiliary contacts (changeover type)
OF or CAM (early make or break) 29450
OF or CAM low level (early make or break) 29452
E18608
16
A 12
8
4
0
160/5
Rotary handles
Extended front control
For INS320/400/630 with standard rotary handle 31052
For INS320/400/630 with red handle on yellow front (1) 31053
E89617
¿5...8
+ Ronis 1351B.500 keylock (1 keylocks / 1 key) 41950
or + Profalux KS5 B24 D4Z keylock (1 keylocks / 1 key) 42878
Installation accessories
Front panel escutcheons
For INS/INV 31080
For ammeter module, IP40 29318
E18591
NS800/1000/1250/1600
INV2000/2500 combination with NS2000/2500 31317 31318
Connection accessories
Vertical connection adapters
INS/INV630b/1600 3P Set of 3 31301
4P Set of 4 31302
E88701
Spreaders
INS/INV630b/1600 3P Set of 3 31305
4P Set of 4 31306
E88703
Insulation accessories
Base for terminal shield (incompatible avec séparateur de phases)
INS/INV630b/1600 3P 31307
4P 31308
E88704
Electrical auxiliaries
Auxiliary contacts (changeover type)
OF or CAM (early make or break) 29450
OF or CAM low level (early make or break) 29452
E18608
Installation accessories
Escutcheon
INS630b/1600 3P/4P 31295
E88707
DBTP308E 07-2002