You are on page 1of 50

Custombuilt.

book Page 2 Friday, February 27, 2004 8:21 AM

Contents

Product data Pumps


Custom-built pumps page 3 Horizontally mounted pumps page 20
Variant overview page 3 Pumps with bearing flange page 22
Performance range page 4 Belt-driven pumps page 24
Type keys page 5 Pumps for liquid temperatures
Codes page 5 down to –40°F page 26
How to read a curve chart page 6 Carbon-free pumps page 27
Curve conditions page 6 Silicon-free pumps page 27
Pumps for pharmaceutical and
biotechnological applications page 28
Motors TriClamp page 28
General information page 7 Cleaned and dried pumps page 29
Efficiency class page 8 Electropolished pumps page 29
Benefits offered by high efficiency motors page 8
Pump range page 8 Low-NPSH pumps
NEMA TEFC Motor Efficiency Standards &
Baldor Super-E Efficiency page 8 Low-NPSH pumps page 30

Shaft seal arrangements Performance curves


Double seal (tandem) page 9 CR 5 page 32
Double seal (back-to-back) page 10 CR 10 page 33
Back-to-back double seal CR 15 page 34
with pressure intensifier page 11 CR 20 page 35
Back-to-back double seal with dosing pump page 11 CR 32 page 36
Cool-Top® (high temperatures) page 12 CR 45 page 37
CR 64 page 38
Shaft seals
4-pole versions
Shaft seal with FFKM or FXM O-ring material page 14
Hybrid shaft seal page 15 CR pumps with 4-pole motors page 39

Certificates Performance curves


Certificates page 16 CR 1 page 40
ATEX-approved CR pumps page 17 CR 3 page 41
CR 5 page 42
CR 10 page 43
MAGdrive CR 15 page 44
Magnetic-drive pump (MAGdrive) page 18 CR 20 page 45
CR 32 page 46
CR 45 page 47
LiqTec CR 64 page 48
CR 90 page 49
LiqTecTM dry-running sensor page 19

Motor data
ODP motors page 50
TEFC motors page 51

2
Custombuilt.book Page 3 Friday, February 27, 2004 8:21 AM

Product data Custom-built pumps

Custom-built pumps Variant overview


Grundfos offers a wide range of custom-built variants of The overview of custom-built solutions refers only to
the CR type range for a variety of demanding industrial the CR, CRI, CRN range.
applications. Featuring superior reliability like the
The overview is divided into the following parts:
standard products, the custom-built pumps meet the
strictest demands for durability and trouble-free opera- • Motors
tion. • Shaft seals
With these multistage in-line pumps, based on the well- • Pumps.
known CR type range, Grundfos meets the customers’
needs for pumps capable of handling Motors
• high-temperature liquids The standard range of motors meets a wide variety of
application demands.
• high-viscosity liquids such as paints and varnishes
For special applications or operating conditions,
• volatile and explosive liquids and
Grundfos offers custom-built motors such as
• aggressive liquids
• explosion-proof motors for hazardous atmospheres
• special installation requirements.
(including ATEX approved motors)
The Grundfos CR range • motors with anti-condensation heating unit for hu-
Material versions: mid environments
• High efficiency motors
• Cast iron/stainless steel, AISI 304 = CR
• Motors with different enclosure class
• Stainless steel, AISI 304 = CRI
• Oversized motors
• Stainless steel, AISI 316 = CRN
• motors with thermal protection.
• Titanium = CRT
Pump types: Shaft seals
CR 1s, 1, 3, 5, 10, 15, 20, 32, 45, 64 and 90. Grundfos offers a wide range of special-purpose shaft
seals and shaft seal arrangements for the pumping of
Pumped liquid temperature: liquids such as
–40°F to +356°F. • aggressive or corrosive liquids
This product guide gives an overview of some of the • particle-carrying liquids
custom-built solutions offered by Grundfos. If the • toxic or explosive liquids
product guide does not provide a solution to your
• high-viscosity or sticky liquids
specific pumping needs, please contact your local
Grundfos company with a detailed description of your and for operating under conditions such as
application!
• extremely high pressures
• extremely high or low temperatures.

Pumps
The pump can be custom-built for special operating
conditions and applications such as
• high inlet pressures
• high-pressure systems up to 725 psi
• horizontal mounting
• applications demanding belt-driven pumps
• pharmaceutical and biotechnological applications
• applications requiring low NPSH.
GR5357

3
Custombuilt.book Page 4 Friday, February 27, 2004 8:21 AM

Product data Custom-built pumps

Performance range
H H
[m] [ft] 60 Hz
1500
400
300 1000
800
200
600

400
100
300
80
CR 1s CR 3 CR 10 CR 20 CR 45 CR 90
60 200
CRI 1s CRI 3 CRI 10 CRI 20 CRN 45 CRN 90
50 CRN 1s CRN 3 CRN 10 CRN 20
150 CR 1 CR 5 CR 15 CR 32 CR 64
40 CRI 1 CRI 5 CRI 15 CRN 32 CRN 64
CRN 1 CRN 5 CRN 15
30 100
80
20
60
4 6 8 10 20 30 40 60 80 100 200 300 400 600 800
Q [US GPM]

1 2 3 4 5 6 8 10 20 30 40 50 60 80 100 Q [m³/h]
Eta
[%]
80

60

40

20

TM02 8376 5103


4 6 8 10 20 30 40 60 80 100 200 300 Q [US GPM]
High-pressure range

4
Custombuilt.book Page 5 Friday, February 27, 2004 8:21 AM

Product data Custom-built pumps

Type keys Example A -F -A -E -H QQ E


Materials
CR(E), CRI(E), CRN(E) A Basic version
D Carbon-graphite filled PTFE (bearings)
Example CR E 32 (s) -4 -2 -A -G -G -E -HQQE G Wetted parts AISI 316
Type range: All parts stainless steel, wetted
CR, CRI, CRN GI
parts AISI 316
Pump with integrated I Wetted parts AISI 304
frequency control All parts stainless steel, wetted
II
Flow rate [m3/h] parts AISI 304
All impellers with reduced K Bronze (bearings)
diameter (applys only to CR, CRI, CRN 1s) S SiC bearings + PTFE neck rings
Number of impellers X Special version
Number of reduced diameter Code for rubber parts
impellers (CR(E), CRN(E) 32, 45, 64, 90) E EPDM
Code for pump version F FXM
Code for pipe connection K FFKM
V FKM
Code for materials
Shaft seal
Code for rubber parts
A O-ring seal with fixed driver
Code for shaft seal
B Rubber bellows seal
E Cartridge seal with O-ring
H Balanced cartridge seal with O-ring
K Type M as cartridge seal
O Double seal, back-to-back
P Double seal, tandem
X Special version
B Carbon, synthetic resin-impregnated

Codes H
Q
Cemented tungsten carbide, embedded (hybrid)
Silicon carbide
Example A -F -A -E -H QQ E U Cemented tungsten carbide
Pump version X Other ceramics
A Basic version 1) E EPDM
B Oversize motor F FXM
E Cetificate/approval K FFKM
CR pump for high temperatures V FKM
F
(air-cooled top assembly) 1) In August 2003 the NEMA version pump code was discontinued for all
H Horizontal version material numbers created by Grundfos manufacturing companies in
High-pressure pump with high North America. The NEMA version pump code will still remain in effect
HS for existing material numbers. NEMA version pumps built in North
speed MLE motor
America after this change will have either an A or U as the pump version
I Different pressure rating
code depending on the date the material number was created.
J Pump with different max speed
K Pump with low NPSH
M Magnetic drive
N Fitted with sensor
P Undersize motor
R Horizontal version with bearing bracket
SF High pressure pump
Over size motor
T
(two flange sizes bigger)
U NEMA version 1)
X Special version
Pipe connection
A Oval flange
B NPT thread
CA FlexiClamp (CRI(E), CRN(E) 1, 3, 5, 10, 15, 20)
CX Triclamp (CRI(E), CRN(E) 1, 3, 5, 10, 15, 20)
F DIN flange
G ANSI flange
J JIS flange
N Changed diameter of ports
P PJE coupling
X Special version

5
Custombuilt.book Page 6 Friday, February 27, 2004 8:21 AM

Product data Custom-built pumps

How to read a curve chart


Pump type and frequency

H H H
[m] [ft] [ft]
220 CR 32 220
200 200
60 -2 CRN 32
180 -2-1 180 QH curves for the individual pumps.
2-pole, 60 Hz
50 160 160 The bold curves indicate the recom-
Number of stages mended performance range for best
First figure indicates number of 140 140 efficiency.
40
stages, second figure indicates 120 120 The thin curves are only to be used as
number of reduced-diameter a guide.
impellers. 30 100 100
80 80
20
60 60
40 40
10
20 20
The power curves indicate
pump input power per stage. 0 0 0
Chart shows curve for pump 0 20 40 60 80 100 120 140 160 Q [US GPM]
with full-diameter impeller (1/1)
and reduced-diameter impeller
(2/3). 0 5 10 15 20 25 30 35 40 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
4 Eff 1/1 80 The eta curve shows pump effi-
3 2/3 60 ciency. The efficiency of pumps
2 with reduced-diameter impellers
2 40
1 1 20 is approx. 2% lower than the eta
0 0 0 curve shown in the chart.
0 20 40 60 80 100 120 140 160 Q [US GPM]

H NPSH NPSH
[m] [ft] [ft]
NPSHR
8 30 30
The NPSH curve is an average
20 20 curve for all the variants shown.
4 10 10 When sizing the pumps, add a

TM02 8377 5103


0 0 0 safety margin of at least 0.5 m.
0 20 40 60 80 100 120 140 160 Q [US GPM]

Curve conditions The curve below shows the minimum flow rate as a
percentage of the nominal flow rate in relation to the
The guidelines below apply to the curves shown in this liquid temperature.
data booklet.
The dotted curve represents a pump fitted with an air-
1. The motors used for the measurements are the same cooled top.
as the motors used in the standard range.
2. Performance may vary based on motor selection. Qmin
3. Measurements have been made with airless water at [%]
a temperature of 68°F. 30

4. The curves apply to a kinematic viscosity of 20


υ = 1 mm2/s (1 cSt). 10
5. Due to the risk of overheating, the pumps should
TM02 7538 3703

0
not be used at a flow below the minimum flow rate.
104
40 140
60 176
80 212 248
120 284 320 180
140 160 356 t [°F]

6
Custombuilt.book Page 7 Friday, February 27, 2004 8:21 AM

Motors Custom-built pumps

General information
The Grundfos standard range of motors covers a wide
variety of application demands. For special applications
or operating conditions, Grundfos offers custom-built
motors, such as:

Variant Description
If technically possible, Grundfos can fit the pump with a motor of a brand other than the
Different motor brand standard. This will normally increase the time of delivery. Alternatively, the pump can be
supplied without a motor (motor thrust rating must be checked).
Different position of motor Where possible, the terminal box can be placed on either side of the pump.
Explosion-proof motor For operation in hazardous atmospheres.
As standard, Grundfos can supply:
• ODP: open drip-proof; TEFC: total-enclosed fan-cooled
On request, we can supply:
Different enclosure class
• Chemical processing/mill and chem duty
• Washdown duty (Up through 10 hp only)
• Other
Anti-condensation heating Built-in heating unit, especially for humid environments.
(space heaters) All heating units are supplied with 1 x 115V, 60Hz.
All Grundfos CR pumps 10 hp and below are available as standard with an integrated variable
Integrated variable speed drive
speed drive (type MLE) motor.
Special supply voltage Motors suitable for other voltages are available upon request.
Motor insulation class Upgrade from Class F to Class H.
• EPAct/NRC—motor efficiency according to EPAct/NRC standards
Efficiency class
• Premium efficiency
Ambient temperatures above 104° F or installation at altitudes of more than
Oversized motor
3,300 feet above sea level may require the use of an oversized motor (i.e. derating).
Tropicalized windings Motors recommended for operating in areas with high humidity.
Wye/Delta starting Motor wired for Wye/Delta starting (6 leads).
Grundfos’ laboratory is authorized to issue test sheets for motors; for instance,
Test sheets
for insurance companies.

7
Custombuilt.book Page 8 Friday, February 27, 2004 8:21 AM

Motors Custom-built pumps

Efficiency class Pump range


Energy Efficient and Premium Efficiency motors are
Grundfos offers motors with Energy Efficient EPAct/NRC
available for all Grundfos CR pumps.
class and Premium Efficiency class. When Premium Effi-
ciency motors are ordered, the Baldor Super-E® motor is
supplied which in most cases exceeds the NEMA Premium Pump
Efficiency standards. CR 1s CR 1 CR 3 CR 5 CR 10 CR 15 CR 20 CR 32 CR 45 CR 64 CR 90
type
CR z z z z z z z z z z
Benefits offered by high efficiency motors CRI z z z z z z
CRN z z z z z z z z z z
• Improved efficiency (see graph below)
• Lower noise level
• Higher permissible ambient temperature
• Longer bearing life due to reduced temperature

NEMA TEFC Motor Efficiency Standards & Baldor TEFC Super-E Efficiency

100

95

90
Efficiency (%)

85

80

75

70
1 1.5 2 3 5 7.5 10 15 20 25 30 40 50 60
HP
TEFC EPAct/NRC TEFC Premium Eff. TEFC Super-E

Note: ODP Efficiency points are in table below.


ODP TEFC
HP
EPAct/NRC Premium Eff. Super-E EPAct/NRC Premium Eff. Super-E
1 -- 77.0 84.0 75.5 77.0 78.5
1 1/2 82.5 84.0 85.5 82.5 84.0 85.5
2 84.0 85.5 86.5 84.0 85.5 86.5
3 84.0 85.5 87.5 85.5 86.5 88.5
5 85.5 86.5 90.2 87.5 88.5 89.5
7 1/2 87.5 88.5 90.2 88.5 89.5 91.0
10 88.5 89.5 91.7 89.5 90.2 91.7
15 89.5 90.2 91.7 90.2 91.0 91.7
20 90.2 91.0 92.4 90.2 91.0 92.4
25 91.0 91.7 93.0 91.0 91.7 93.0
30 91.0 91.7 93.6 91.0 91.7 93.0
40 91.7 92.4 94.1 91.7 92.4 93.6
50 92.4 93.0 93.6 92.4 93.0 94.1
60 93.0 93.6 94.5 93.0 93.6 94.1

Notes:
1. The term “High Efficiency” is commonly used but is not recognized in the NEMA standards (MG 1-1198, Part 12).
2. Some standard CR pump motors already meet the EPAct/NRC requirement. See the CR, CRI, CRN Product Guide.
NEMA TEFC
Baldor Super-E
Motor
Efficiency
Efficiency Standards &

8
Custombuilt.book Page 9 Friday, February 27, 2004 8:21 AM

Shaft seal arrangements Custom-built pumps

Double seal (tandem) CR, CRI, CRN 10, 15 and 20

General information
Double seals mounted in tandem are recommended for
use with crystallizing, hardening or sticky liquids. Outlet 1/2"

Reference applications
• Pharmaceutical industry (production of dextran)
• Negative pressure deaeration systems (vacuum)
• Industries handling potentially hardening oil
products
• Caustic soda (sodium hydroxide - NaOH)
• Hydrated lime (calcium hydroxide - Ca(OH) 2).

TM02 7386 3403


Inlet 1/2"
Pump range
The tandem type of seal is available for the following
Grundfos pumps:
Pump CR, CRN 32, 45, 64 and 90
CR 1s CR 1 CR 3 CR 5 CR 10 CR 15 CR 20 CR 32 CR 45 CR 64 CR 90
type
CR z z z z z z z z z z
CRI z z z z z z
CRN z z z z z z z z z z
Outlet 3/8"
Technical description Inlet 3/8"

This type of double seal consists of two shaft seals


mounted in a tandem arrangement in a separate seal
chamber. Only Grundfos cartridge shaft seals can be
used.
If the primary seal is leaking, the pumped liquid will be
flushed away by the flushing liquid. The flushing liquid
pressure must always be lower than the pumped liquid

TM01 6204 1699


pressure.
• •

Recommended flushing liquid conditions:


• Q = 6.6-52.8 gallon/hour
• p = 58-87 psi
Dimensions
Sectional drawings Additional height of seal chamber *
Pump type
[in]
CR, CRI, CRN 1, 3 and 5
CR, CRI, CRN 1, 3 and 5 4 1/4
CR, CRI, CRN 10, 15 and 20 3 1/2
CR, CRN 32, 45, 64 and 90 0
Outlet 1/2" * As compared to a standard pump.

Reference numbers
Pump type Reference number
CR, CRI, CRN 1, 3 and 5 98 97 08
CR, CRI, CRN 10, 15 and 20 98 94 70
CR, CRN 32, 45, 64 and 90 98 98 05
TM02 2139 3701

Inlet 1/2"

9
Custombuilt.book Page 10 Friday, February 27, 2004 8:21 AM

Shaft seal arrangements Custom-built pumps

Double seal (back-to-back) Sectional drawings


CR, CRI, CRN 1, 3 and 5
General information
Double seals mounted "back-to-back" are recommended
for use with toxic, aggressive or explosive liquids. The
back-to-back double seal protects the surrounding envi-
ronment and the people working in the vicinity of the Shaft seal
pump.
This type of seal is the optimum solution for handling
abrasive or sticky liquids which would either wear out,
damage or block a mechanical shaft seal. Shaft seal

Reference applications

TM02 1691 1801


• Paint industry
• Distilling plants
• Petrochemical industry.
CR, CRI, CRN 10, 15 and 20
Pump range
The back-to-back type of seal is available for the
following Grundfos pumps:
Pump Shaft seal
CR 1s CR 1 CR 3 CR 5 CR 10 CR 15 CR 20 CR 32 CR 45 CR 64 CR 90
type
CR z z z z z z z z z z
CRI z z z z z z
CRN z z z z z z z z z z

Technical description Shaft seal

The back-to-back double seal consists of two shaft seals

TM02 7385 3403


mounted in a back-to-back arrangement in a separate
seal chamber.
The pressure in the seal chamber must be higher than
the pump pressure. The pressure in the seal chamber can
CR, CRN 32, 45, 64 and 90
be generated by
• a pressure intensifier when the operating pressure is Shaft seal
above 232 psi (see page 12)
• a separate pump, e.g. a dosing pump, when the ope-
rating pressure is less or equal to 232 psi (see page 12)
or
• an existing, separate pressure source. Many applica-
tions incorporate pressurized systems.
The back-to-back double seal arrangement with pressu-
rized seal chamber prevents the pumped liquid from
leaking through the shaft seal to the environment.

Reference numbers
Pump type Reference number
CR, CRI, CRN, 1, 3 and 5 98 97 09
CR, CRI, CRN, 10, 15 and 20 98 94 71
TM02 5000 2002

CR 32, 45, 64 and 90 98 98 10


CRN 32, 45, 64 and 90 98 97 87

10
Custombuilt.book Page 11 Friday, February 27, 2004 8:21 AM

Shaft seal arrangements Custom-built pumps

Back-to-back double seal Back-to-back double seal


with pressure intensifier with dosing pump

Pressure intensifier

Double seal TM01 4455 0399

tm01 9099 1701


CR, CRI, CRN pump
Barrier fluid

Dimensions Note: One dosing pump installation can supply several


pumps fitted with back-to-back double seal.
Connections are all ½".
Note: Connecting pipes/hoses are not included.
Dimensions
Additional height of seal chamber
Pump type
[in]
CR, CRI, CRN 1, 3, 5 4 1/4
CR, CRI, CRN, 10, 15 and 20 3 1/2
CR, CRN 32 8 1/4
b

CR, CRN 45 9 1/2


CR, CRN 64 6 1/2
a c CR, CRN 90 7 1/4

Reference numbers
TM01 4459 0399

Reference number
Dosing pump,
max. 232 psi 98 98 09

a b c
Pump type
[in] [in] [in]
CR, CRI, CRN 1, 3 and 5 11 3/4 4 1/4 5
CR, CRI, CRN, 10, 15 and 20 12 3/4 3 1/2 5 1/2
CR, CRN 32 13 1/2 8 1/4 6
CR, CRN 45 13 3/4 9 1/2 6 1/2
CR, CRN 64 13 3/4 6 1/2 6 1/2
CR, CRN 90 14 7 1/4 6 3/4

The dimension b is the additional height as compared to


the standard pump.
Reference numbers
Material Reference number
Pressure intensifier
AISI 316, FKM 98 98 92
(not available for CRT)
AISI 316, EPDM 98 98 91

11
Custombuilt.book Page 12 Friday, February 27, 2004 8:21 AM

Shaft seal arrangements Custom-built pumps

Cool-Top® (high temperatures) Temperatures above 248°F normally result in a substan-


tial reduction of seal life due to poor lubrication of the
seal faces. As the temperature in the seal chamber does
not exceed 248°F during operation, a standard Grundfos
shaft seal can be used.
The Grundfos air-cooled top does not require any
external cooling. An automatic air vent is required to
vent the pump seal chamber.
Air-cooled top with bearing flange
For applications involving pumping of water up to 356°F,
the pump requires a net positive inlet pressure,
according to the vapour pressure of water.
To prevent the axial thrust generated by the inlet pres-
sure from being transmitted to the motor shaft and
bearings, a bearing flange is fitted between pump and
motor.
A bearing flange is incorporated in the following
Grundfos pump types:
GR5228

60 Hz
CRI, CRN 10-1 --> 10-5
CRI, CRN 15-1 --> 15-2
General information CRI, CRN 20-1
The unique Grundfos air-cooled top shaft seal solution is CR, CRN 32-1-1 --> 32-2
recommended for applications involving high tempera- CR, CRN 45-1-1 --> 45-1
tures from 248°F to 356°F. CR, CRN 64-1-1 --> 64-2-1
CR, CRN 90-1-1 --> 90-2-2
The Cool-Top pumps are equipped with FXM rubber
parts. The max. permissible operating pressure of pumps with
air-cooled top for temperatures up to 356°F is 362 psi.
Reference applications
Dimensions
• Boiler feeding
Additional pump height
• Temperature control, e.g. in moulding processes Pump type
[in]
• Circulation of transmission oils. CRI, CRN 1, 3 and 5 4 1/4
CRI, CRN 10, 15 and 20 3 1/2
Pump range CR, CRN 32 8 1/4
The Cool-Top is available for the following Grundfos CR, CRN 45 9 1/2
pumps: CR, CRN 64 6 1/2
CR, CRN 90 7 1/4
248-356°F
Pump Reference numbers, air-cooled top for 248-356°F
CR 1s CR 1 CR 3 CR 5 CR 10 CR 15 CR 20 CR 32 CR 45 CR 64 CR 90
type
Pump type Reference number
CR z z z z
CRI, CRN 1, 3 and 5 98 96 40
CRI z z z z z z
CRI, CRN, 10, 15 and 20 98 94 73
CRN z z z z z z z z z z
CR 32, 45, 64 and 90 98 96 38
Technical description CRN 32 and 45 98 96 37
CRN 64 and 90 98 96 36
The air-cooled top separates the seal chamber from the
pump by an air-cooled chamber, generating an insu-
lating effect similar to that of a thermos.
Via the narrow passage between the pump and the air-
cooled top, a small quantity of the pumped liquid recir-
culates by natural circulation.

12
Custombuilt.book Page 13 Friday, February 27, 2004 8:21 AM

Shaft seal arrangements Custom-built pumps

Sectional drawings
CRI, CRN 1, 3 and 5 CRI, CRN 10, 15 and 20

Air vent 1/2"

Air vent

Liquid
Shaft seal
Liquid

Bushing
Shaft seal Air chamber

Air chamber

Pipe

TM02 7384 3403


TM02 1693 1801

CR, CRN 32, 45, 64 and 90

Air vent 1/2"

Shaft seal

Liquid

Air Pipe
chamber






Bushing
TM01 4785 0899

13
Custombuilt.book Page 14 Friday, February 27, 2004 8:21 AM

Shaft seals Custom-built pumps

Shaft seals Shaft seal with FFKM or FXM O-ring


General information material
Liquids or applications exceeding the range of normal General information
operating conditions require special-purpose shaft seal
Shaft seals with FFKM or FXM O-ring material are recom-
solutions.
mended for applications where the pumped liquids may
To ensure reliability and avoid untimely breakdowns, damage the standard O-ring material.
the following conditions must be considered:
See the list of pumped liquids in the CR, CRI, CRN data
• temperature, booklet.
• pressure,
Reference applications, FFKM (Kalrez®)
• pumped liquid.
• Chemical industry (aggressive liquids)
In order to meet any specific requirements, Grundfos • Petrochemical industry (oils)
offers the following variants:
• High-temperature applications.
1. Shaft seals with FFKM or FXM O-ring material
Plug and sleeve O-rings made of FFKM are also available
2. Hybrid shaft seals for CR, CRI, CRN 1s, 1, 3, 5, 10, 15 and 20.
Recommended operating range Reference applications, FXM (Flouraz®)
The actual operating range of the shaft seal depends on • High-temperature applications (instead of FKM).
the operating pressure, pump type, type of shaft seal
and liquid temperature. The following table applies to Plug and sleeve O-rings made of FXM are available for
clean water and water containing glycol. the full range.

For explanation of codes, see the type key on page 5. Pump range
Min. Max. Pressure Shaft seals with FFKM or FXM O-ring are available for the
Pump type Shaft seal temp. temp. rating following Grundfos pumps:
[°F] [°F] [psi]
HUBx 32 248 435 Pump
CR 1s CR 1 CR 3 CR 5 CR 10 CR 15 CR 20 CR 32 CR 45 CR 64 CR 90
type
CR, CRI, CRN HUUx –40 194 435
1s, 1, 3, 5, 10, 15, 20, FFKM z z z z z z z z z z z
32, 45, 64, and 90 HQQx –40 248 435
FXM z z z z z z z z z z z
HQBx 0 248 435
Technical description
Rubber type Min. temperature [°F] Max. temperature [°F]
The FFKM and FXM O-rings replace the standard shaft
EPDM –40 248
seal O-rings.
FKM –4 194
FXM 14 527 Dimensions
FFKM –4 527
Dimensions are identical to those of the standard shaft
Maximum operation temperature is 248°F for the standard range. seal.
Pumps equipped with an Cool-Top the maximum opera-
tion temperature is 356°F. Reference numbers
Reference number
Pump type
FFKM FXM
CR, CRI, CRN 1s, 1, 3 and 5 98 99 72 98 96 78
CR, CRI, CRN 10, 15 and 20 98 94 74 98 94 75
CR, CRN 32, 45, 64 and 90 98 98 15 98 96 77

14
Custombuilt.book Page 15 Friday, February 27, 2004 8:21 AM

Shaft seals Custom-built pumps

Hybrid shaft seal Sectional drawing

General information
Hybrid shaft seals are recommended for applications
involving a risk of dry running and are available as a
standard shaft seal on CR, CRN 32, 45, 64 and 90; seal
type KUHE.

Reference applications
• Boiler-feed applications
• Applications involving degassing of liquids
• Industrial applications involving frequent priming.

Pump range

TM02 4279 0402


Hybrid shaft seals are available for the following
Grundfos pumps:
Hybrid seal design
Pump
CR 1s CR 1 CR 3 CR 5 CR 10 CR 15 CR 20 CR 32 CR 45 CR 64 CR 90
type
CR z z z z
Dimensions
CRI Dimensions are identical to those of the standard shaft
CRN z z z z seal.

Technical description Reference numbers


The stationary seat of the shaft seal is equipped with an Pump type Reference number
extra, special-carbon seal face, expanding at high CR, CRN 32, 45, 64 and 90 Standard
temperatures as a result of dry running or similar condi-
tions.
This eliminates the usual damaging effects of dry
running, such as leakage and noise.

15
Custombuilt.book Page 16 Friday, February 27, 2004 8:21 AM

Certificates Custom-built pumps

Certificates

ATEX-approved pump

Customer name
Customer order no.
Grundfos order no.
Pump type
Part number
Production code
Pump serial no.
Motor serial no.
ATEX approval of pump

Grundfos hereby confirms that the pump mentioned above is manufactured according the
specifications mentioned in the “CR, CRI, CRN Custom-built pumps” data booklet. This means
the pump is conformity with the ATEX 94/9EEC (ATEX 100) appendix VIII directive as men-
tioned in the “ATEX Supplement to installation and operating instructions” supplied with the
pump.

Surface roughness
According to ISO 1302

Customer name
Customer order no.
Grundfos order no.
Pump type
Part number
CRN base part number

The surface roughness is measured as the maximum roughness of the CRN inlet and outlet
surface.
GRUNDFOS
Date: 7-Jan-04

Signature:
Name:
Dept.:

Part no 96 51 22 40/A51137

Surface treatment Roughness Roughness


None value RA [µm] degree
Electro-polished 50 N 12
25 N 11
12.5 N 10
6.3 N9
3.2 N8
GR5381

1.6 N7
Measured values 0.8 N6
R max µm 0.4 N5
0.2 N4
RT µm
0.1 N3
RA µm 0.05 N2
RZ µm 0.025 N1

Vibration report
According to ISO 10816

GRUNDFOS
Measured object Date: 7-Jan-04
Pump type Part number

General information P2 (kW)


Number of poles

Test conditions
Frequency (Hz)
Serial no.
Signature:
Name:
Dept.:
Part no 96 50 79 31/A51137
The pump is floor- Voltage (V) Frequency: (Hz)
mounted on vibration

Grundfos offer a number of certificates for different


Flow (m³/h) Head (m)
absorbers. For vibration velocity measurement positions, see figure.

Remarks

purposes. The following types are available... Result of measurement:


Pos RMS vibration
Typical zone boundry limits
RMS vibration Class I Class II
velocity (mm/s) velocity (mm/s)
1 0.28
0.45 A
2 A

• material certificates
0.71
3 1.12
B
1.8
4 2.8
B
C
5 4.5
C
7.1
6

( certificates stating material components or 7


8
9
11.2
18
28
45
D

The machine classifications are as follows:


D

Class I: Individual parts of engines and machines, integrally

material specifications) connected to the complete machine in its normal operating


condition. (Production electrical motors of up to 15 kW are
typical examples of machines in this category.)

Class II: Medium-sized machines (typically electrical motors


with 15 kW to 75 kW output) without special foundations,
rigidly mounted engines or machines (up to 300 kW) on spe-
cial foundations.

• performance certificates
(printed test reports guaranteeing and certifiing test GRUNDFOS
Date: 7-Jan-04

Signature:

data of QH performance, current consumption Name:


Dept.:

Part no 96 50 79 32/A51137

curves, rpm, etc.)


• authorized test by third party
(surveyed performance test)
Certificate Standard
• ATEX approved CR pumps
Material specification report
(according to ATEX-directive 94/9/EC)
Material report with certificate
The certificates must be ordered with the pump. Report
ATEX-approved pump
Reference applications Inspection certificate EN 10.204 3.1.B

• Pharmaceutical industries Inspection certificate


- Lloyds Register of Shipping (LRS),
• Ships and offshore - Det Norske Veritas (DNV)
EN 10.204 3.1.C
- Germanisher Lloyd (GL)
• Big contractors - Bureau Veritas (BV)
- Etc.....
• Areas exposed to explosive atmosphere
Surface roughness report
Pump range Motor test report
Standard test report ISO 9906
Certificates are available for the following pump types:
Vibration report
Pump Certificate of compliance with the
CR 1s CR 1 CR 3 CR 5 CR 10 CR 15 CR 20 CR 32 CR 45 CR 64 CR 90 EN 10.204 2.1
type order
CR z z z z z z z z z z z Test report - non specific inspection
EN 10.204 2.2
CRI z z z z z z z and testing
CRN z z z z z z z z z z z Report
Cleaned and dried pump
Report
Electro-polished pump

16
Custombuilt.book Page 17 Friday, February 27, 2004 8:21 AM

Certificates Custom-built pumps

ATEX-approved CR pumps

General information
The CR pumps can be approved according to EC directive
94/9/EC, the so-called ATEX directive.
The pumps can be used in areas (zones) classified
according to the directive 1999/92/EC. In case of doubt,
please consult the above-mentioned directives or
contact Grundfos.
ATEX-approved pumps will be supplied with serial
number, special installation and operating instructions
and a nameplate including the ATEX classification.
An ATEX-approved pump report is available on request.

Scope of ATEX categories for CR pumps


Group I
Category M2
Pumps made of materials that
Underground installations in mines lia-
do not create sparks and thus do
ble to be endangered by explosive gas-
not constitute any danger of
ses or combustible dust.
explosion.
CR pumps available CR, CRI, CRN
Motors available None*
* Air or hydraulic motors are not available from Grundfos.

Group II
Category 2 Category 3
Installation areas liable to be endan- Pumps intended for use in areas in which Pumps intended for use in areas in which
gered by explosive atmospheres. explosive atmospheres are likely to occur. explosive atmospheres only rarely occur.
G (gas) D (dust) G (gas) 2) D (dust)
CR pumps available CR, CRI, CRN 1) CR, CRI, CRN, CRT CR, CRI, CRN, CRT CR, CRI, CRN, CRT
VEM 2G EEx e IIT3 VEM 2G EEx e IIT3
Motors available VEM 2D 125°C VEM 3D 125°C
CEMP 2G EEc d IIB T4 CEMP 2G EEc d IIB T4

1)
Solutions including MAGdrive or double shaft seal.
2) Note: To enable the use of category 3 G CR pumps in zone 1 areas, the minimum requirement is a dry-running protection aprroved for zone 1.
The dry-running protection must stop the pumps if the liquid supply ceases.

17
Custombuilt.book Page 18 Friday, February 27, 2004 8:21 AM

MAGdrive Custom-built pumps

Magnetic-drive pump (MAGdrive) Dimensions


Standard motor MAGdrive motor Additional height
General information [Hp] [Hp] [in]
1/2 1/4 3 1/8
The zero-leakage, custom-built pump with magnetic
1/2 1 4 3/4
drive (MAGdrive) is recommended for the pumping of
1/2 1 1/2 4 3/4
hazardous or aggressive liquids. Grundfos MAGdrive
3/4 1 1/2 4 3/4
protects the surrounding environment and the people
3/4 2 7 1/3
working in the vicinity of the pump.
1 1 1/2 2 7/8
Reference applications 1 2 5 1/2
1 1/2 1 1/2 2 7/8
• Chemical industry (aggressive or toxic liquids)
1 1/2 2 5 1/2
• Petrochemical industry (volatile liquids) 1 1/2 3 5 1/2
• Pharmaceutical industry. 2 2 2 7/8
2 3 2 7/8
Pump range 3 3 2 7/8
The following Grundfos pumps are available with 3 4 5
MAGdrive: 4 4 2 3/4
4 5 1/2 4 3/4
Pump
CR 1s CR 1 CR 3 CR 5 CR 10 CR 15 CR 20 CR 32 CR 45 CR 64 CR 90 5 1/2 5 1/2 2 3/4
type
CR 5 1/2 7 1/2 4
CRI 7 1/2 7 1/2 2
CRN z z z z 7 1/2 10 2
10 10 2
Technical description
In the Grundfos MAGdrive pump, the power from the Operating range
motor is transmitted to the pump shaft by means of Viscosity range Max. pressure Temp. range
Pump type
magnetic force instead of by a traditional coupling. The [cp] [psi] [°F]
magnetic field is generated by two magnets; the outer CRN 1s, 1, 3 and 5 0.3 - 150 232/362 –22 to +356
magnet is driven by the motor and the inner magnet is
connected to the pump. Due to the power loss, the Reference numbers
MAGdrive is cooled by the pumped liquid. Pump type Reference number
CRN 1s-2 to CRN 1s-27 98 94 82
As all axial forces are absorbed in the MAGdrive, a
standard motor with key hole must be used. CRN 1-2 to CRN 1-27 98 97 07
CRN 3-2 to CRN 3-25 98 97 05
Grundfos MAGdrive is based on a standard MAK 66
CRN 5-2 to CRN 5-12 98 97 03
magnetic Burgmann coupling.
CRN 5-13 to CRN 5-24 98 97 02
Sectional drawing The following rubber part solutions are available:
• EPDM
• FXM
• FFKM
• FKM.
Note: When ordering a Grundfos MAGdrive, please
Pump shaft
250 provide the following:
Can
265 Magnets
• liquid temperature [°F]
Bearing
258 • liquid viscosity [cp]
• frequency [Hz]
• voltage [V].
TM02 1721 1901

Axial bearing
259
Above information is required for the selection of the
correct MAGdrive/motor combination.

18
Custombuilt.book Page 19 Friday, February 27, 2004 8:21 AM

LiqTec Custom-built pumps

LiqTecTM dry-running sensor Installation example

L1
L2
L3

N
Sensor
K1

T+

T+
M

TM02 4291 0402


3
External T+
restart

White

Yellow
Black
Brown
General information
The Grundfos LiqTec dry-running sensor stops the pump
immediately if there is no liquid present in the pump.
The LiqTec also serves as overheating protection of the
motor.
The sensor is easily inserted through the pump head
close to the shaft seal.

TM02 4311 0402


Reference applications
K1
Any application involving a risk of dry running.

Pump range
The LiqTec is available for the following Grundfos Dimensions
pumps:
4 5/8 x 3 9/16 in. The LiqTec can be fitted to a DIN rail to
Pump be incorporated in a control cabinet.
CR 1s CR 1 CR 3 CR 5 CR 10 CR 15 CR 20 CR 32 CR 45 CR 64 CR 90
type
CR z z z z z z z z z z z Operating range
CRI z z z z z z z
1 x 80-130 V or
CRN z z z z z z z z z z z Power supply
1 x 200-240 V
Power consumption 5W
Technical description
Max. pressure 580 psi
The LiqTec transmits a heat impulse through the sensor, Min./max. liquid temperature –4°F/248°F
measuring the temperature of the sensor. Liquid in the Max. ambient temperature 104°F
pump cools the sensor as well as the shaft seal and other Humidity 99%
pump parts. Pumped liquid Any liquid handled by Grundfos pumps
If there is no liquid present, the LiqTec detects a high Cable length 16 1/2 / 49 1/4 feet
temperature in the sensor and cuts out the pump imme- Reference numbers
diately to prevent damage. The risk of pump breakdown
is thus further reduced by up to 50%. Pump type Reference number
CR, CRI, CRN 1s, 1, 3, 5, 10, 15, 20, 32, 45, 64 and 90 99 96 82
Restarting after a pump cut-out can be done automati-
cally or manually when liquid in the pump is again
detected by the sensor. Remote restarting is possible via
a digital input.
The electronic control unit can also be connected to the
pump thermistor measuring the motor temperature. In
case of overheating of the motor, the system cuts out
the pump. For installation of the Grundfos LiqTec, see
the installation example in the right column.

19
Custombuilt.book Page 20 Friday, February 27, 2004 8:21 AM

Pumps Custom-built pumps

Horizontally mounted pumps Dimensional drawings


CR, CRI, CRN 1s, 1, 3, 5,
CR, CRI, CRN 10, 15 and 20 <= 5 Hp
B1

H
GR5379
L
X
C

General information
For safety and space-saving reasons, the pump can be

TM02 8372 5003


mounted in the horizontal position.
B
Reference applications B

• Ships
• Earthquake areas (low center of gravity) CR, CRI, CRN 10, 15 and 20 >=7.5 Hp
• Places with limited access and space. B1

Pump range
The following Grundfos pumps are available for hori-

H
zontal mounting:
L
Pump X
CR 1s CR 1 CR 3 CR 5 CR 10 CR 15 CR 20 CR 32 CR 45 CR 64 CR 90
type
CR z z z z z z z z z z z
CRI z z z z z z z AB
8

CRN z z z z z z z z z z z
D

TM02 8373 5003


AAA
AA
Also available for CRT 2, 4, 8, 16. A
B
4 x ø14
BB

Technical description
B

The pumps are supplied with separate mounting plates


for support of pump and motor. CR, CRN 32, 45, 64 and 90

Note: The following pump types are fitted with a B3 / B5


foot/flange mounted motor:
• CR, CRI, CRN 1 to 20 with motors ≥ 10 Hp and
H

X
• CR, CRN 32, 45, 64 and 90.
L
Reference numbers
Pump type Reference number
CR, CRI, CRN 1s, 1, 3 and 5 98 99 51
CR, CRI, CRN 10, 15 and 20 <= 5 Hp 98 94 76
CR, CRI, CRN 10, 15 and 20 >= 7.5 Hp 98 94 77 256

CR, CRN 32, 45, 64 and 90 98 98 53


AB
8
D

AAA
TM02 7426 3403

AA
A

4 x ø19
BB
B

20
Custombuilt.book Page 21 Friday, February 27, 2004 8:21 AM

Pumps Custom-built pumps

Dimensions
CR, CRI, CRN 1s, 1 , 3 and 5, support for base plate and pump head
X X
[in] [in]
Motor B H L C Connections
[hp] [in] [in] [in] [in] ANSI Oval, PJE, FlexiClamp
1/2-2 B1-3 3/8
3-5 5 1/2 5 1/2 2 B1-3 1/4 4 1/8 3 1/8
7 1/2-10 B1-4 7/8

For pump height B1, see the CR, CRI, CRN Product Guide.
CR, CRI, CRN 10, 15 and 20, support for base plate and pump head
CR, CRI, CRN 10 CR, CRI, CRN 15/20
X X
[in] [in]
Motor B H L C Connections
[hp] [in] [in] [in] [in] ANSI, Oval, PJE, Flexiclamp ANSI, Oval, PJE, Flexiclamp
1/2-2 B1-3 1/4
6 3/4 6 7/8 2 4 3/8 4 3/4
3-5 B1-4 3/8

For pump height B1, see the CR, CRI, CRN Product Guide.

CR, CRI, CRN 10, 15 and 20, support for base plate and motor
CR, CRI, CRN 10 CR, CRI, CRN 15/20
X X
[in] [in]
Motor A AA AAA B BB D H L AB Connections
[hp] [in] [in] [in] [in] [in] [in] [in] [in] [in] ANSI, Oval, PJE, Flexiclamp ANSI, Oval, PJE, Flexiclamp
7 1/2 8 1/2 2 7/8 14 1/2 5 1/2 7 1/8 2 5/8 7 7/8 1 /4 10 7/8
10 8 1/2 2 7/8 14 1/2 5 1/2 7 1/8 2 5/8 7 7/8 1 /4 10 7/8
15 10 5 1/8 16 3/4 8 1/4 10 1/4 1 1/2 7 7/8 1 /4 12 3/4 4 3/8 4 3/4
20 10 5 1/8 16 3/4 8 1/4 10 1/4 1 1/2 7 7/8 1 /4 13 1/8
25 10 5 1/8 16 3/4 10 12 1/4 1 1/2 7 7/8 1 /4 13 1/8

CR, CRN 32, 45, 64 and 90, support for base plate and motor
CR, CRN 32 CR, CRN 45, 64, 90
X X
[in] [in]
Motor A AA AAA B BB D AB H L Connection
[hp] [in] [in] [in] [in] [in] [in] [in] [in] [in] ANSI
2 5 1/2 12 5/8 15 5 6 1/2 7 7/8 8 5/8 11 3/8 2 3/8
3 5 1/2 12 5/8 15 5 6 1/2 7 7/8 8 5/8 11 3/8 2 3/8
5 7 1/2 14 1/2 17 5 1/2 7 1/8 7 10 7/8 11 3/8 2 3/8
7 1/2 8 1/2 15 1/2 18 5 1/2 7 1/8 6 1/4 11 7/8 11 3/8 2 3/8
10 8 1/2 15 1/2 18 5 1/2 7 1/8 6 1/4 11 7/8 11 3/8 2 3/8
15 10 17 3/8 19 5/8 8 1/4 10 7/8 5 1/8 13 3/8 11 3/8 2 3/8
8 3/8 7
20 10 18 20 1/4 8 1/4 10 1/2 5 1/8 13 3/8 11 3/8 2 3/8
25 10 18 20 1/4 10 12 1/4 5 1/8 13 3/8 11 3/8 2 3/8
30 11 19 21 1/2 9 1/2 12 1/4 4 3/8 14 3/8 11 3/8 2 3/8
40 12 1/2 21 1/4 23 5/8 12 14 3/8 3 1/2 16 1/8 11 3/8 2 3/8
50 12 1/2 21 1/4 23 5/8 12 14 3/8 3 1/2 16 1/8 11 3/8 2 3/8
60 14 22 7/8 25 1/4 12 1/4 14 1/2 2 1/2 17 3/4 11 3/8 2 3/8

21
Custombuilt.book Page 22 Friday, February 27, 2004 8:21 AM

Pumps Custom-built pumps

Pumps with bearing flange The bearing flange requires a standard motor with
keyway.
Note: For motor sizes above 15 hp, the bearing flange is
equipped with grease nipples and must be lubricated
regularly. Please follow the instructions on the bearing
Bearing flange flange.

Sectional drawings
CR, CRI, CRN 1s, 1, 3, 5, <= 7.5 Hp
CR, CRI, CRN 10, 15 and 20 , <= 5 Hp
NEMA 56 C - NEMA 213-5 TC

TM01 4354 0199

General information

TM02 7436 3403


A bearing flange is used in two situations:
• A standard motor with standard ball bearing configu-
ration is required:
The bearing flange absorbs the hydraulic load from CR, CRI, CRN 10, 15 and 20, > 5 Hp
the pump, ensuring an acceptable motor bearing life.
NEMA 254 TC - NEMA 284 TC
• The pump is required to run at a higher inlet pressure
than the maximum pressure recommended:
The bearing flange prevents movement of the angu-
lar contact bearing in the motor.

Reference applications
High-pressure applications such as
• cleaning

TM02 7437 3403


• boiler-feed water treatment
• reverse osmosis.

Pump range
The following Grundfos pumps are available with CR, CRN 32, 45, 64 and 90, <= 10.0 Hp
bearing flange: NEMA 182 TC - NEMA 215 TC

Pump
CR 1s CR 1 CR 3 CR 5 CR 10 CR 15 CR 20 CR 32 CR 45 CR 64 CR 90
type
CR z z z z z z z z z z z
CRI z z z z z z z
CRN z z z z z z z z z z z

Also avaiable for CRT 2, 4, 8, 16.

Technical description
TM01 4352 0199

A bearing flange is an additional flange with an oversize


ball bearing to absorb axial forces in both directions. The
coupling is part of the bearing flange fitted in order to
obtain optimum alignment.

22
Custombuilt.book Page 23 Friday, February 27, 2004 8:21 AM

Pumps Custom-built pumps

CR, CRN 32, 45, 64 and 90, >10 Hp Reference numbers


NEMA 254 TSC - NEMA 365 TSC
CR, CRI, CRN 1s, 1, 3, 5, <= 7.5 Hp
CR, CRI, CRN 10, 15 and 20, <= 5 Hp
Bearing type Reference
Motor type Motor power
in flange number
NEMA 56C/148.2 1/3 - 2 [Hp] 6308 2RS C3 98 96 51
NEMA F182 TC 3 - 5 [Hp] 6310 2RS C3 98 96 50
NEMA 213-5 TC 7 1/2 [Hp] 6310 2RS C3 98 96 49

CR, CRI, CRN 10, 15 and 20,> 5 Hp


Bearing type Reference
Motor type Motor power
in flange number
NEMA 254-6 15 [Hp] QJ 216 MPA 98 94 87
NEMA 284-6 20-40 [Hp] QJ 216 MPA 98 94 88

CR, CRN 32, 45, 64 and 90


TM01 4353 0503 Bearing type Reference
Motor type Motor power
in flange number
NEMA 182 TC 3-5 [Hp] 6310 2RS 98 98 45
NEMA 213 TC
7 1/2-10 [Hp] 6310 2RS 98 98 14
NEMA 215 TC
NEMA 254 TSC
15 [Hp] QJ 216 MPA 98 98 42
Dimensions NEMA 256 TSC
NEMA 284 TSC
The following additional height must be added to the NEMA 286 TSC
20-40 [Hp] QJ 216 MPA 98 98 41
total height of the pump: NEMA 324 TSC
NEMA 326 TSC
CR, CRI, CRN 1s, 1, 3, 5, 10, 15 and 20 NEMA 364 TSC
50-60 [Hp] QJ 216 MPA 98 98 40

Additional NEMA 365 TSC


Motor type Motor power height
[in]
NEMA 56C/148.2 1/3 - 2 [Hp] 1 1/2
NEMA F182 TC 3 - 5 [Hp] 1 3/4
NEMA 213-5 TC 7 1/2 [Hp] 1 3/4
NEMA 254-6 15 [Hp] 3 7/8
NEMA 284-6 20-40 [Hp] 5 1/3

CR, CRN 32, 45, 64 and 90


Additional
Motor type Motor power height
[in]
NEMA 182 TC - NEMA 215 TC 3 - 10 [Hp] 7/8
NEMA 254 TSC - NEMA 365 TSC 15 - 60 [Hp] 5/8

23
Custombuilt.book Page 24 Friday, February 27, 2004 8:21 AM

Pumps Custom-built pumps

Belt-driven pumps Technical description


An additional bearing has been added on top of an
existing bearing flange. The two bearings are mounted
back-to-back. This bearing design makes it possible to
withstand the extra radial forces caused by a pulley.
A pulley wheel is attached to the end of the shaft.
By means of pulley belts, the pump can be driven by a

GR5886
motor mounted next to it rather than on top of it.
The pump can be mounted horizontally or vertically by
General information using the extra support plates.

A belt-driven pump is designed to operate in places with The pulley head is positioned on the motor stool where
limited space or where no electrical power is available. the motor would normally be fitted. Using the existing
holes in the motor stool, the pulley head can be secured
Reference applications to the motor stool with bolts, washers and nuts. The
Diesel-engine-driven or steam-turbine-driven applica- pulley wheel is then attached to the shaft using an
tions such as: appropriate bush and key.

• applications in remote/distant areas For extended bearing life, the following pulley wheel
sizes are recommended:
• mobile applications
Type III Type IV Type II Type I
• fire protection. Pulley head
1/2 - 7 1/2 Hp 10 - 25 Hp 2 - 10 Hp 15 - 60 Hp
Pump range CR, CRI, CRN
CR, CRI, CRN CR, CRN
Pump type 1s, 1, 3, 5,
The following Grundfos pumps are available as belt- 10, 15, 20
10, 15, 20 32, 45, 64, 90
driven pumps:
Pulley wheel Min.
ø4 3/8- 5 3/8 Min. ø7 7/8 Min. ø6 1/4
Pump diameter ø7 7/8
CR 1s CR 1 CR 3 CR 5 CR 10 CR 15 CR 20 CR 32 CR 45 CR 64 CR 90
type Number of belts 2 Min. 3 Min. 2 Min. 3
CR z z z z z z z z z z z Pump speed
Max 3000
CRI z z z z z z z [rpm]

CRN z z z z z z z z z z z

Also available for CRT 2, 4, 8, 16.

24
Custombuilt.book Page 25 Friday, February 27, 2004 8:21 AM

Pumps Custom-built pumps

Sectional drawings Dimensions


CR, CRI, CRN 1s, 1, 3, 5, 10, 15 and 20 (type III) Additional height
Pump type Pulley head from top of motor stool
[in]
CR, CRI, CRN 1s, 1, 3, 5, 10, 15, 20 Type III 5 3/4
CR, CRI, CRN 10, 15, 20 Type IV 12 1/4
Type II 4 7/8
CR, CRN 32, 45, 64 and 90
Type I 5 7/8

TM02 4783 1602


Reference numbers
Pump type Pulley head Reference number
CR, CRI, CRN 1s, 1, 3, 5, 10, 15, 20 Small 98 96 48
CR, CRI, CRN 10, 15, 20 Type II 98 94 89
Type II 98 96 47
CR, CRI, CRN 10, 15 and 20 (type IV) CR, CRN 32, 45, 64 and 90
Type I 98 96 46

For horizontal installation, the belt-driven pumps are


supplied with both brackets as standard.
TM02 7451 3503

CR, CRN 32, 45, 64 and 90 (type II)


TM02 4785 1602

CR, CRN 32, 45, 64 and 90 (type I)


TM02 4784 1602

25
Custombuilt.book Page 26 Friday, February 27, 2004 8:21 AM

Pumps Custom-built pumps

Pumps for liquid temperatures Technical description


down to –40°F CRI, CRN 1s, 1, 3, 5, 10, 15 and 20 feature
• PTFE neck rings with inner diameter exceeding stand-
ard dimensions.
Please note that pumped liquids containing antifreeze
often require the use of oversize motors due to the
higher viscosity of these liquids.

Dimensions
Dimensions are identical to those of a standard pump.

Reference numbers
Pump type Reference number
CRI, CRN 1s, 1, 3 and 5 98 98 75

GR5219
CRI, CRN 10, 15 and 20 98 94 78

General information
Grundfos offers pumps suitable for the pumping of
liquids of extreme temperatures down to –40°F.

Reference applications
• Cooling systems with antifreeze and brines
• Ventilation systems
• Industrial processes.

Pump range
The following Grundfos pumps are available for liquid
temperatures down to –40°F:
Pump
CR 1s CR 1 CR 3 CR 5 CR 10 CR 15 CR 20 CR 32 CR 45 CR 64 CR 90
type
CR
CRI z z z z z z z
CRN z z z z z z z    
 The standard CRN 32, 45, 64 and 90 pumps fitted with shaft seal type
HQQE are capable of operating at liquid temperatures down to –40°F.

26
Custombuilt.book Page 27 Friday, February 27, 2004 8:21 AM

Pumps Custom-built pumps

Carbon-free pumps Silicon-free pumps


General information General information
Certain processes such as industrial processes in the Silicon-free pumps are suitable for processes requiring
electronics industry require the use of pumps containing the use of pumps not containing silicon.
absolutely no carbon fibers.
Reference applications
Reference applications • Production of paint and varnish
• Ultra-purification processes • Cleaning processes in the electronics industry.
• Flushing processes in the electronics industry.
Pump range
Pump range The following Grundfos pumps are available as silicon-
The following Grundfos pumps are available as carbon- free pumps:
free pumps:
Pump
CR 1s CR 1 CR 3 CR 5 CR 10 CR 15 CR 20 CR 32 CR 45 CR 64 CR 90
Pump type
CR 1s CR 1 CR 3 CR 5 CR 10 CR 15 CR 20 CR 32 CR 45 CR 64 CR 90
type CR z z z z z z z z z z z
CR        z z z z CRI z z z z z z z
CRI        CRN z z z z z z z z z z z
CRN        z z z z
 CR, CRI, CRN 1s, 1, 3, 5, 10, 15 and 20 are carbon-free as standard if Technical description
non-carbon seal face material is chosen.
A silicon-free pump differs from a standard pump in the
following ways:
Technical description
A carbon-free pump differs from a standard pump in the • Only FKM rubber is used.
following ways: • All components, except the electric motor, are
washed in "DX 380 Low-Voc cleaner".
• Bearings are made of SiC/SiC.
• Spare parts ordered together with the pump are also
• Neck rings and bushes are made of carbon-free PTFE
washed in "DX 380 Low-Voc cleaner".
(white PTFE).
• The pump is assembled in a room separated from the
Dimensions production area.
Dimensions are identical to those of a standard pump. • Tools used for the assembly of the pump do not
contain silicon.
Reference numbers
• The assembled pump is checked visually;
Pump type Number of stages Reference number performance is not tested.
1-2 98 98 02
• The pump is wrapped in silicon-free plastic before
CR, CRN 32, 45, 64 and 90 3-7 98 96 94
being packing.
8 - 14 98 96 93
Dimensions
Dimensions are identical to those of the standard pump.

Reference numbers
Pump type Reference number
CR, CRI, CRN 1s, 1, 3, 5, 10, 15 and 20
98 99 54
CR, CRN 32, 45, 64 and 90

27
Custombuilt.book Page 28 Friday, February 27, 2004 8:21 AM

Pumps Custom-built pumps

Pumps for pharmaceutical and TriClamp


biotechnological applications A base with TriClamp connection is of a hygienic design
with a sanitary coupling for use in the pharmaceutical
General information and food industry.
The Grundfos CRN range is designed for applications The gasket is made of PTFE or EPDM.
requiring the sterilization and CIP capability of pipes,
valves and pumps. (CIP = Cleaning-In-Place). Pump range
In addition, some applications make special demands on The base with TriClamp connection is available for the
the system in terms of safety or process technology. following Grundfos pumps:
Certificates can be ordered on request for Pump
CR 1s CR 1 CR 3 CR 5 CR 10 CR 15 CR 20 CR 32 CR 45 CR 64 CR 90
type
• WRC
CR
• FDA (rubber parts) CRI z z z z z z z
• different material certificates, see page 16. CRN z z z z z z z

Solutions
Grundfos offers the following solutions to meet these
special requirements:
• TriClamp connection
• Cleaned and dried pumps
• Electropolished pumps.

GR5841_base
Reference numbers
Base with TriClamp connection
Pump type Reference number
CRI, CRN 1s, 1, 3 and 5 98 96 92
CRI, CRN 10 , 15 and 20 98 94 79

GR5841_clamp

Part numbers
Two gaskets and two couplings
Pipework Gasket Part
Pump type
connection parts number
CRI, CRN 1s, 1, 3 and 5 1 1/2" EPDM 96 51 53 74
CRI, CRN 1s, 1, 3 and 5 1 1/2" PTFE 96 51 53 75
CRI, CRN 10 , 15 and 20 2" EPDM 96 51 53 76
CRI, CRN 10 , 15 and 20 2" PTFE 96 51 53 77

28
Custombuilt.book Page 29 Friday, February 27, 2004 8:21 AM

Pumps Custom-built pumps

Cleaned and dried pumps Electropolished pumps


Pump range General information
The following Grundfos pumps are available as cleaned To substantially reduce the risk of corrosion of the
and dried pumps: materials and improve the cleanability.
Pump Reference applications
CR 1s CR 1 CR 3 CR 5 CR 10 CR 15 CR 20 CR 32 CR 45 CR 64
type
CR z z z z z z z z z z The pharmaceutical-/food-/electronic industry.
CRI z z z z z z z
CRN z z z z z z z z z z
Pump range
The following Grundfos pumps are available as elec-
Also available for CRT 2, 4, 8, 16.
tropolished pumps:
Technical description Pump
CR 1s CR 1 CR 3 CR 5 CR 10 CR 15 CR20 CR 32 CR 45 CR 64 CR 90
type
Prior to assembly, the pump components are washed in
CR
pure, hot soap water, rinsed in de-ionised water, and
CRI
dried.
CRN z z z z z z z z z z z
Note: Cleaned and dried pumps are not performance
tested in a test bed. Technical description
The pumps are wrapped in a plastic bag before being The pump incorporates a standard shaft seal which has
packed. not been polished.
Electro-polishing removes burrs as well as metallic and
Reference numbers
non-metallic inclusions, providing an extremely smooth,
Pump type Reference number clean and corrosion-resistant stainless steel surface.
CRI, CRN 1s, 1, 3, 5, 10, 15 and 20 98 98 70
CR, CRN 32, 45, 64, 90 98 96 41
First all components are pickled in a mixture of nitric
acid and hydrofluoric acid. Subsequently, the compo-
nents are electropolished in a mixture of sulphuric acid
and phosphoric acid. Finally, the components are passi-
vated in nitric acid.
The CRN 1s, 1, 3, 5, 10, 15 and 20 casted parts are all
mechanically polished before being electropolished.
Surface
Stainless steel Stainless steel
Pump type roughness
casted parts plate parts
[µ in]
z equal to or
CRN 1s, 1, 3, 5, 10, 15 and 20
z below 32
z 400-600
CRN 32, 45, 64, 90 equal to or
z
below 32

Dimensions
Dimensions are identical to those of the standard pump.

Reference numbers
Pump type Reference number
CRN 1s, 1, 3, 5 98 97 60
CRN 10, 15, 20 98 94 80
CRN 32, 45, 64, 90 98 96 25

29
Custombuilt.book Page 30 Friday, February 27, 2004 8:21 AM

Low-NPSH pumps Custom-built pumps

Low-NPSH pumps Sectional drawing

General information
The low-NPSH pumps are designed for poor suction
conditions and/or high application temperatures.
The pumps are specially suited for handling poor inlet
flows and liquid temperatures above 140°F.

Reference applications Special inlet


• Boiler-feed applications impeller

• Applications involving a risk of poor inlet/suction


conditions
• High-temperature applications. Special inlet
part
Pump range
The following Grundfos pumps are available as low-
NPSH pumps:
Pump
CR 1s CR 1 CR 3 CR 5 CR 10 CR 15 CR 20 CR 32 CR 45 CR 64 CR 90
type
CR z z z z z z z z
CRI z z z z z
CRN z z z z z z z z

TM01 8865 1200


Technical description
The low-NPSH pump are standard pumps provided with
a special, oversized inlet impeller and chamber. This
reduces the NPSH value and prevents erosion and Operating range
destruction of pump, piping system and valves.
Max. pressure 362 psi
The improved inlet design may expose the low-NPSH Max. liquid temperature 248°F 
pump to a higher level of stress as compared to conven- Max. ambient temperature 104°F
tional pumps, without affecting the stability of opera-  Max. liquid temperature is 356°F combined with the Cool-Top.
tion.
Reference numbers
Dimensions and weights Pump type Reference number
Low-NPSH pumps have the same dimensions and CR, CRI, CRN 3 98 96 76
weights as standard CR, CRI, CRN pumps. This informa- CR, CRI, CRN 5 98 96 84
tion can be found in the CR(E), CRI(E), CRN(E) Product CR, CRI, CRN 10, 15, 20 98 94 81
Guide. CR, CRN 32, 45, 64 98 97 64

30
Custombuilt.book Page 31 Friday, February 27, 2004 8:21 AM

Performance curves Low-NPSH pumps


CR 3, CRI 3, CRN 3

H H H
[m] [ft] [ft]
800 CR 3 800
240 -25
750 CRI 3 750
220
700
-23 CRN 3 700

200 -21 2-pole, 60 Hz


650 650

180 600 -19 600

550 550
160 -17
500 500

140 -15
450 450

-13
120 400 400
-12
350 -11 350
100
-10
300 300
-9
80
250 -8 250
-7
60 200 200
-6
150 -5 150
40 -4
100 -3 100
20
50 50

0 0 0
0 2 4 6 8 10 12 14 16 18 20 22 Q [US GPM]

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
P2
0.15 60
0.10
0.10 Eff 40
0.05
0.05 20

0.00 0.00 0
0 2 4 6 8 10 12 14 16 18 20 22 Q [US GPM]
H NPSH NPSH
[m] [ft] [ft]
15 NPSHR 15
4
10 10
Low NPSHR
2
5 5
TM02 8378 5103CR 3

0 0 0
0 2 4 6 8 10 12 14 16 18 20 22 24Q [US GPM]

31
Custombuilt.book Page 32 Friday, February 27, 2004 8:21 AM

Performance curves Low-NPSH pumps


CR 5, CRI 5, CRN 5

H H H
[m] [ft] [ft]
800 CR 5 800
240 -24
750 CRI 5 750
220
700 -22 CRN 5 700

200 2-pole, 60 Hz
650 -20 650

180 600 600


-18
550 550
160 -16
500 500
-15
140 450 -14 450
-13
120 400 400
-12
350 -11 350
100 -10
300 300
-9
80 -8
250 250
-7
60 200 -6 200

150 -5 150
40 -4
100 100
20
50 50

0 0 0
0 5 10 15 20 25 30 35 40 45 Q [US GPM]

0 1 2 3 4 5 6 7 8 9 10 11 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
0.3 P2 60
0.2 Eff
0.2 40
0.1
0.1 20

0.0 0.0 0
0 5 10 15 20 25 30 35 40 45 Q [US GPM]
H NPSH NPSH
[m] [ft] NPSHR [ft]
15 15
4
10 10
2 Low NPSHR
5 5
TM02 8379 5103CR 5

0 0 0
0 5 10 15 20 25 30 35 40 45 Q [US GPM]

32
Custombuilt.book Page 33 Friday, February 27, 2004 8:21 AM

Performance curves Low-NPSH pumps


CR 10, CRI 10, CRN 10

H H H
[m] [ft] [ft]
800
-17 CR 10 800
240
750
-16 CRI 10 750
220
700 CRN 10 700

200 -14 2-pole, 60 Hz


650 650

180 600 600


-12
550 550
160
500 500
-10
140 450 450
-9
120 400 400
-8
350 350
100 -7
300 300
-6
80
250 250
-5
60 200 200
-4
150 150
40 -3
100 100
20
50 50

0 0 0
0 5 10 15 20 25 30 35 40 45 50 55 60 Q [US GPM]

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
0.8 80
P2
0.6 Eff 60
0.4
0.4 40
0.2
0.2 20

0.0 0.0 0
0 5 10 15 20 25 30 35 40 45 50 55 60 Q [US GPM]
H NPSH NPSH
[m] [ft] [ft]
NPSHR
15 15
4
10 10
2
5 Low NPSHR 5
TM02 8380 5103CR 10

0 0 0
0 5 10 15 20 25 30 35 40 45 50 55 60 Q [US GPM]

33
Custombuilt.book Page 34 Friday, February 27, 2004 8:21 AM

Performance curves Low-NPSH pumps


CR 15, CRI 15, CRN 15

H H H
[m] [ft] [ft]
850 CR 15 850
-12
240
800 CRI 15 800

750 CRN 15 750


220
700 -10 2-pole, 60 Hz 700

200 650 650


-9
180 600 600
-8
550 550
160
500 -7 500
140 450 450
-6
120 400 400
-5
350 350
100
300 -4 300
80
250 250
-3
60 200 200
-2
150 150
40
100 100
20
50 50

0 0 0
0 10 20 30 40 50 60 70 80 90 100 110 Q [US GPM]

0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
2.0 Eff 80

1.5 P2 60
1.0
1.0 40
0.5
0.5 20

0.0 0.0 0
0 10 20 30 40 50 60 70 80 90 100 110 Q [US GPM]
H NPSH NPSH
[m] [ft] [ft]
NPSHR
15 15
4
10 10
2 Low NPSHR
5 5
TM02 8381 5103CR 15

0 0 0
0 10 20 30 40 50 60 70 80 90 100 110 Q [US GPM]

34
Custombuilt.book Page 35 Friday, February 27, 2004 8:21 AM

Performance curves Low-NPSH pumps


CR 20, CRI 20, CRN 20

H H H
[m] [ft] [ft]
CR 20
600 600
180
-8 CRI 20
550 550
CRN 20
160
500
-7 2-pole, 60 Hz 500

140
450 450
-6

120 400 400


-5
350 350
100
300 -4 300

80
250 250
-3

60 200 200

-2
150 150
40

100 100

20
50 50

0 0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 Q [US GPM]

0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
4 Eff 80

3 60
2
P2
2 40
1
1 20

0 0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 Q [US GPM]
H NPSH NPSH
[m] [ft] [ft]
30 30
8 NPSHR

20 20
4
10 10
TM02 8382 5103CR 20

Low NPSHR
0 0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 Q [US GPM]

35
Custombuilt.book Page 36 Friday, February 27, 2004 8:21 AM

Performance curves Low-NPSH pumps


CR 32, CRN 32

H H H
[m] [ft] [ft]
CR 32
-10-2
900 CRN 32 900

-9 2-pole, 60 Hz
250 -9-2
800 800

-8
-8-2
700 700
200 -7
-7-2
600 600
-6
-6-2
150 500 500
-5
-5-2
400 400
-4
-4-2
100
300 300
-3
-3-2
200 -2 200
50 -2-1

100 100

0 0 0
0 20 40 60 80 100 120 140 160 180 200 Q [US GPM]

0 5 10 15 20 25 30 35 40 45 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
4 Eff P2 1/1 80

3 P2 2/3 60
2
2 40
1
1 20

0 0 0
0 20 40 60 80 100 120 140 160 180 200 Q [US GPM]
H NPSH NPSH
[m] [ft] [ft]
30 NPSHR 30
8
20 Low NPSHR 20
4
10 10
TM02 8383 5103CR 32

0 0 0
0 20 40 60 80 100 120 140 160 180 200 Q [US GPM]

36
Custombuilt.book Page 37 Friday, February 27, 2004 8:21 AM

Performance curves Low-NPSH pumps


CR 45, CRN 45

H H H
[m] [ft] [ft]
CR 45
900 CRN 45 900
-7
-7-1
-7-2
2-pole, 60 Hz
250
800 800

-6
-6-1
700 -6-2 700
200

600 -5 600
-5-1
-5-2

150 500 -4 500


-4-1
-4-2
400 400
-3
-3-1
100 -3-2
300 300

-2
-2-1
200 200
50

100 100

0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 Q [US GPM]

0 5 10 15 20 25 30 35 40 45 50 55 60 65 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
6 Eff
8 P2 1/1 80

6 P2 2/3 60
4
4 40
2
2 20

0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 Q [US GPM]
H NPSH NPSH
[m] [ft] [ft]
30 30
8
20 NPSHR 20
4
10 10
TM02 8384 5103CR 45

Low NPSHR
0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 Q [US GPM]

37
Custombuilt.book Page 38 Friday, February 27, 2004 8:21 AM

Performance curves Low-NPSH pumps


CR 64, CRN 64

H H H
[m] [ft] [ft]
CR 64
600 -5-2 600
180
-4
CRN 64
550 2-pole, 60 Hz 550
160 -4-1
500 500
-4-2
140
450 450
-3

120 400 400


-3-1

350 350
100 -3-2

300 300
-2
80
250 -2-1 250

60 200 200

150 150
40

100 100

20
50 50

0 0 0
0 40 80 120 160 200 240 280 320 360 400 440 Q [US GPM]

0 10 20 30 40 50 60 70 80 90 100 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
12 16 80
Eff
12 P2 1/1 60
8
8 P2 2/3 40
4
4 20

0 0 0
0 40 80 120 160 200 240 280 320 360 400 440 Q [US GPM]
H H NPSH
[m] [ft] [ft]
30 NPSHR 30
8
20 20
4 Low NPSHR
10 10
TM02 8385 5103CR 64

0 0 0
0 40 80 120 160 200 240 280 320 360 400 440 Q [US GPM]

38
Custombuilt.book Page 39 Friday, February 27, 2004 8:21 AM

4-pole versions Custom-built pumps

CR pumps with 4-pole motors Technical description


Calculation of motor size:
Use the P2 curve on the following curve sheets to calcu-
late the 4-pole motor size.
The minimum motor size available for each pump type is
shown in the table.
Motor size
Pump size
[HP]
CR 1 1/3
CR 3 1/3
CR 5 1/3
CR 10 1/3
CR 15 1/3
CR20 1/3
CR 32 3
CR 45 3
CR 64 3
CR 90 3
GR5381

Reference numbers
Pump type Reference number
CR, CRI, CRN 1, 3, 5, 10, 15 and 20
General information 99 97 24
CR, CRN 32, 45 and 64
CR standard pumps fitted with 4-pole motors.
Dimensions and weights
Reference applications CR pumps with 4-pole motors will be shorter in height
• Applications where a low sound pressure level is and weigh less than standard Grundfos CR pumps. This
required is due to the smaller horsepower motors and motor
• Applications with poor inlet conditions. stools required to power the pump at 4-pole perfor-
mance.
Pump range
The following Grundfos pumps are available as 4-pole
versions:

Pump
CR 1s CR 1 CR 3 CR 5 CR 10 CR 15 CR 20 CR 32 CR 45 CR 64 CR 90
type
CR z z z z z z z z z z
CRI z z z z z z
CRN z z z z z z z z z z

39
Custombuilt.book Page 40 Friday, February 27, 2004 8:21 AM

Performance curves 4-pole versions


CR 1, CRI 1, CRN 1

H H H
[m] [ft] [ft]
CR 1
200 200
60 -27 CRI 1
180 -25 CRN 1 180
4-pole, 60 Hz
-23
50
160 160
-21

140 -19 140


40
-17
120 120

-15

30 100 100
-13
-12
80 -11 80
-10
20 -9
60 -8 60
-7
-6
40 40
-5
10
-4
20 -3 20
-2

0 0 0
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 Q [US GPM]

0.0 0.5 1.0 Q [m³/h]


P2 P2 Eff
[kW] [hp] [%]
0.015 60
0.010 P2
0.010 40
Eff
0.005
0.005 20

0.000 0.000 0
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 Q [US GPM]
H NPSH NPSH
[m] [ft] [ft]
3 3
0.8
2 2
0.4
1 NPSHR 1
TM02 8386 5103CR 1

0.0 0 0
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 Q [US GPM]

40
Custombuilt.book Page 41 Friday, February 27, 2004 8:21 AM

Performance curves 4-pole versions


CR 3, CRI 3, CRN 3

H H H
[m] [ft] [ft]
CR 3
200 200
60 -25 CRI 3
180 -23
CRN 3 180
4-pole, 60 Hz
50 -21
160 160

-19
140 140
40 -17

120 120
-15

100 -13 100


30
-12
-11
80 -10 80
-9
20
60 -8 60
-7
-6
40 -5 40
10 -4
-3
20 20
-2

0 0 0
0 1 2 3 4 5 6 7 8 9 10 11 Q [US GPM]

0.0 0.5 1.0 1.5 2.0 2.5 Q [m³/h]


P2 P2 Eff
[kW] [hp] [%]
Eff
0.03 60
0.02
P2
0.02 40
0.01
0.01 20

0.00 0.00 0
0 1 2 3 4 5 6 7 8 9 10 11 Q [US GPM]
H NPSH NPSH
[m] [ft] [ft]
3 3
0.8
2 2
NPSHR
0.4
1 1
TM02 8387 5103CR 3

0.0 0 0
0 1 2 3 4 5 6 7 8 9 10 11 Q [US GPM]

41
Custombuilt.book Page 42 Friday, February 27, 2004 8:21 AM

Performance curves 4-pole versions


CR 5, CRI 5, CRN 5

H H H
[m] [ft] [ft]
CR 5
200 200
60 -24 CRI 5
180
CRN 5 180
-22
4-pole, 60 Hz
50 -20
160 160

-18
140 140
40 -16
120 -15 120
-14
-13
30 100 100
-12
-11
80 -10 80
-9
20 -8
60 60
-7
-6
40 -5 40
10 -4
-3
20 20
-2

0 0 0
0 2 4 6 8 10 12 14 16 18 20 22 Q [US GPM]

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
0.04 P2 80

0.03 60
0.02 Eff
0.02 40
0.01
0.01 20

0.00 0.00 0
0 2 4 6 8 10 12 14 16 18 20 22 Q [US GPM]
H NPSH NPSH
[m] [ft] [ft]
1.2 4 4

3 3
0.8
2 2
0.4
1 1
NPSHR
TM02 8388 5103CR 5

0.0 0 0
0 2 4 6 8 10 12 14 16 18 20 22 Q [US GPM]

42
Custombuilt.book Page 43 Friday, February 27, 2004 8:21 AM

Performance curves 4-pole versions


CR 10, CRI 10, CRN 10

H H H
[m] [ft] [ft]
CR 10
220 220
CRI 10
-17

60
200 -16 CRN 10 200

4-pole, 60 Hz
180 180
-14
50
160 160
-12
140 140
40
-10
120 120
-9

30 100 -8 100

-7
80 80
-6
20 -5
60 60
-4

40 -3 40
10
-2
20 20
-1

0 0 0
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 Q [US GPM]

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
0.12 Eff 60
0.08
P2
0.08 40
0.04
0.04 20

0.00 0.00 0
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 Q [US GPM]
H NPSH NPSH
[m] [ft] [ft]
6 6

4 4
1
2 2
TM02 8389 5103CR 10

NPSHR
0 0 0
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 Q [US GPM]

43
Custombuilt.book Page 44 Friday, February 27, 2004 8:21 AM

Performance curves 4-pole versions


CR 15, CRI 15, CRN 15

H H H
[m] [ft] [ft]
CR 15
200 -12 200
60 CRI 15
180
CRN 15 180
4-pole, 60 Hz
-10
50
160 160
-9

140 140
-8
40

120 -7 120

100 -6 100
30

-5
80 80

-4
20
60 60
-3

40 40
-2
10

20 -1 20

0 0 0
0 5 10 15 20 25 30 35 40 45 50 55 Q [US GPM]

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
Eff
0.3 60
0.2
0.2 P2 40
0.1
0.1 20

0.0 0.0 0
0 5 10 15 20 25 30 35 40 45 50 55 Q [US GPM]
H NPSH NPSH
[m] [ft] [ft]
1.5 1.5
0.4
1.0 1.0
NPSHR
0.2
0.5 0.5
TM02 8390 5103CR 15

0.0 0.0 0.0


0 5 10 15 20 25 30 35 40 45 50 55 Q [US GPM]

44
Custombuilt.book Page 45 Friday, February 27, 2004 8:21 AM

Performance curves 4-pole versions


CR 20, CRI 20, CRN 20

H H H
[m] [ft] [ft]
CR 20
180 -10 CRI 20 180

50 CRN 20
160 160
4-pole, 60 Hz

140 -8 140
40
-7
120 120

-6
30 100 100

-5

80 80
-4
20
60 60
-3

40 40
-2
10

20 -1 20

0 0 0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 Q [US GPM]

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Q [m³/h]
P2 P2 Eff
[kW] [hp] Eff [%]
0.3 60
0.2
P2
0.2 40
0.1
0.1 20

0.0 0.0 0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 Q [US GPM]
H NPSH NPSH
[m] [ft] [ft]
8 8
2
6 6

4 4
1
2 2
TM02 8391 5103CR 20

NPSHR
0 0 0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 Q [US GPM]

45
Custombuilt.book Page 46 Friday, February 27, 2004 8:21 AM

Performance curves 4-pole versions


CR 32, CRN 32

H H H
[m] [ft] [ft]
-10-2 CR 32
220 220
-9
CRN 32
200 -9-2 4-pole, 60 Hz 200
60
-8
180 -8-2 180

50 -7
160 160
-7-2

140 -6 140
40 -6-2
120 120
-5
-5-2
30 100 100
-4
-4-2
80 80
-3
20
60 -3-2 60

-2
40 -2-1 40
-2-2
10
-1
20 -1-1 20

0 0 0
0 10 20 30 40 50 60 70 80 90 100 Q [US GPM]

0 2 4 6 8 10 12 14 16 18 20 22 24 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
0.8 80

0.6 Eff 60
0.4 P2 1/1
0.4 P2 2/3 40
0.2
0.2 20

0.0 0.0 0
0 10 20 30 40 50 60 70 80 90 100 Q [US GPM]
H NPSH NPSH
[m] [ft] [ft]
8 NPSHR 8
2
6 6

4 4
1
2 2
TM02 8392 5103CR 32

0 0 0
0 10 20 30 40 50 60 70 80 90 100 Q [US GPM]

46
Custombuilt.book Page 47 Friday, February 27, 2004 8:21 AM

Performance curves 4-pole versions


CR 45, CRN 45

H H H
[m] [ft] [ft]
CR 45
220 220
-7 CRN 45
-7-2 4-pole, 60 Hz
200 200
60

180 -6 180
-6-2
50
160 160
-5

140 -5-2 140


40
120 -4 120
-4-2

30 100 100
-3

80 -3-2 80

20
60 -2 60
-2-2
40 40
10 -1
-1-1
20 20

0 0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 Q [US GPM]

0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
1.6 80
Eff
1.2 60
0.8
P2 1/1
0.8 P2 2/3 40
0.4
0.4 20

0.0 0.0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 Q [US GPM]
H NPSH NPSH
[m] [ft] [ft]
6 6

4 4
1
2 NPSHR 2
TM02 8393 5103CR 45

0 0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 Q [US GPM]

47
Custombuilt.book Page 48 Friday, February 27, 2004 8:21 AM

Performance curves 4-pole versions


CR 64, CRN 64

H H H
[m] [ft] [ft]
160 CR 64 160
48
150
-5-2 CRN 64 150
44 4-pole, 60 Hz
140 -4 140

40 130 130
-4-1

36 120 120
-4-2
110 110
32 -3
100 100
-3-1
28 90 90

-3-2
24 80 80
-2
70 70
20
60 -2-1 60
16
50 -2-2 50

12 40 -1 40

30 30
8 -1-1
20 20
4
10 10

0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 Q [US GPM]

0 5 10 15 20 25 30 35 40 45 50 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
2.0 80
Eff
1.5 P2 1/1 60
1.0
1.0 P2 2/3 40
0.5
0.5 20

0.0 0.0 0
0 20 40 60 80 100 120 140 160 180 200 220 Q [US GPM]
H NPSH NPSH
[m] [ft] [ft]
8 8
2 NPSHR
6 6

4 4
1
2 2
TM02 8394 5103CR 64

0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 Q [US GPM]

48
Custombuilt.book Page 49 Friday, February 27, 2004 8:21 AM

Performance curves 4-pole versions


CR 90, CRN 90

H H H
[m] [ft] [ft]
140
CR 90 140

40
-4-2 CRN 90
130 130
4-pole, 60 Hz
120 -3 120
36

110 110
-3-1
32
100 100
-3-2
28
90 90

80 -2 80
24

70 70
-2-1
20
60 60
-2-2
16
50 50

40 -1 40
12

30 -1-1 30
8
20 20
4
10 10

0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 Q [US GPM]

0 5 10 15 20 25 30 35 40 45 50 55 60 65 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
4 80

3 Eff 60
2
2 P2 1/1 40
1 P2 2/3
1 20

0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 Q [US GPM]
H NPSH NPSH
[m] [ft] [ft]
8 NPSHR 8
2
6 6

4 4
1
2 2
TM02 8395 5103CR 90

0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 Q [US GPM]

49
Custombuilt.book Page 50 Friday, February 27, 2004 8:21 AM

Motor data Vertical multistage centrifugal pumps

ODP motors
ODP ODP ODP ODP Mtr. ODP ODP ODP Full ODP service ODP
HP PH Baldor motor
Frame S.F. Voltage Eff. % Insul. class KVA code load current Factor current Start current
1 56C 1.35 115/230 55 B K 6.0/3.0 7.0/3.5 28/14
1/3
3 56C 1.35 208-230/460 70 B J 1.5-1.4/0.7 1.7-1.6/0.8 11-10/5.0
1 56C 1.25 115/208-230 66 B H 7.2/4.0-3.6 8.0/4.4-4.0 30/16.5-15
1/2
3 56C 1.25 208-230/460 68 B J 2.2-2.0/1.0 2.6-2.4/1.2 13.2-12/6.0
1 56C 1.25 115/208-230 66 B K 9.6/5.3-4.8 11.4/6.3-5.7 56/31-28
3/4
3 56C 1.25 208-230/460 74 B K 2.7-2.6/1.3 3.1-3.0/1.5 16.8-15.2/7.6
1 56C 1.40 115/208-230 73 B M 10/5.5-5.0 15/8.0-7.5 85/47-42.5
1
3 56C 1.25 208-230/460 74 B J 3.8-3.6/1.8 3.4-3.2/1.6 19.6-17.8/8.9
1 56C 1.15 115/208-230 68 B H 18/9.9-9.0 19.4/10.7-9.7 121/66.8-60.4
1 1/2
3 56C 1.15 208-230/460 75.5 B G 5.0-4.6/2.3 5.4-5.0/2.5 35.4-32/16
1 56C 1.15 115/208-230 70 B G 24/13.2-12 27.6/15.2-13.8 160/88.5-80
2
3 56C 1.15 208-230/460 81.5 B H 5.9-5.6/2.8 6.7-6.4/3.2 41-37/18.5
1 182TC 1.15 115/208-230 78 B G 28/16-14 32/18.3-16.7 148/81.9-74
3
3 182TC 1.15 208-230/460 82.5 F J 8.4-8.0/4.0 9.5-9.0/4.5 66.4-60/30
1 213TC 1.15 208-230 78 B G 28-26 31/28.7 169-152
5
3 182TC 1.15 208-230/460 87.5 B L 13-12/6.0 14.7-13.6/6.8 139-125/62.3
1 213TC 1.15 208-230 81 B G 38-37 42/41 213-192
7 1/2
3 213TC 1.15 208-230/460 85.5 B J 19-18/9.0 21-20/10 169-152/76
1 213TC 1.15 208-230 83 B G 48-46 53.8-51.7 310-280

TM02 7696 3803


10
3 213TC 1.15 208-230/460 85.5 B H 27-25/12.5 30-28/14 196-177/88.4
15 3 254TC 1.15 208-230/460 85.5 F G 38-36/18 43-41/20.5 290-262/131
3 254TC 1.15 230/460 90.2 B G 48/24 55/27.5 306/153
20
3 284TSC 1.15 230/460 90.2 B G 48/24 55/27.5 306/153
25 3 284TSC 1.15 230/460 91 B G 59/29.5 67/33.5 374/187
30 3 284TSC 1.15 230/460 91 F H 70/35 80/40 480/240
40 3 286TSC 1.15 230/460 91 B G 96/48 110/55 542/271
50 3 324TSC 1.15 230/460 92.4 F G 116/58 134/67 732/366
60 3 364TSC 1.15 230/460 91.7 F G 140/70 161/80.5 914/457

Notes:
1. The information in this chart applies to Grundfos’
specified Baldor® motors.
Grundfos CR pumps are supplied with heavy-duty
2-pole, NEMA C-frame motors built or selected to our
rigid specifications. All CR pump motors have heavy-
duty bearings in them for maximum thrust require-
ments.
It is not recommended that an off-the-shelf standard
Baldor motor be used on a Grundfos pump. Ideally,
the best motor choice would be the Grundfos speci-
fied motor.
2. Other motor types are available (i.e., Explosion proof,
Mill and Chem duty, High Efficiency, etc.), consult lo-
cal Grundfos company for more information.
3. Pumps supplied by Grundfos Canada are normally
supplied with motors from other manufactures. 575
volt motors meet EPAct/NRC efficiency standards.
Dimensions and data will vary, contact local Grund-
fos company for more information.
4. All values are subject to change without notice.

50
Custombuilt.book Page 51 Friday, February 27, 2004 8:21 AM

Motor data Vertical multistage centrifugal pumps

TEFC motors
TEFC
TEFC TEFC TEFC TEFC TEFC TEFC Full TEFC service TEFC
HP PH Mtr. Baldor motor
Frame S.F. Voltage Insul. class KVA code load current Factor current Start current
Eff. %
1 56C 1.35 115/230 55 B K 6.0/3.0 7.6/3.8 28/14
1/3
3 56C 1.35 208-230/460 70 B J 1.5-1.4/0.7 1.7-1.6/0.8 11.1-10/5.0
1 56C 1.6 115/208-230 62 B K 7.4/4.1-3.7 9.8/5.2-4.9 39/21.6-19.5
1/2
3 56C 1.25 208-230/460 68 B J 2.1-2.0/1.0 2.6-2.4/1.2 13.3-12/6.0
1 56C 1.25 115/208-230 66 B K 9.6/5.3-4.8 11.4/6.0-5.7 56/31-28
3/4
3 56C 1.25 208-230/460 74 B K 2.7-2.6/1.3 3.1-3.0/1.5 16.9-15.2/7.6
1 56C 1.25 115/230 66 B K 12/6.0 14.4/7.2 77/38.5
1
3 56C 1.25 208-230/460 74 B J 3.4-3.2/1.6 3.8-3.6/1.8 19.6-17.8/8.9
1 56C 1.3 115/208-230 71 B K 17/9.5-8.6 20.4/11.3-10.2 106/58.6-53
1 1/2
3 56C 1.15 208-230/460 75.5 B G 5.0-4.6/2.3 5.4-5.2/2.6 35.4-32/16
1 56C 1.15 115/230 74 F K 23/11.5 25.4/12.7 156/78
2
3 56C 1.15 208-230/460 78.5 B H 5.7-5.4/2.7 6.5-6.2/3.1 38.7-35/17.5
1 182TC 1.15 115/208-230 75 F H 29/16-14.5 31.8/18-15.9 170/94-85
3
3 182TC 1.15 208-230/460 81.5 F K 8.2-7.8/3.9 9.0-8.6/4.3 77.4-70/35
1 213TC 1.15 208-230 80 F J 24-22 27-25 188-170
5
3 184TC 1.15 208-230/460 85.5 F K 13.2-12/6.0 15-13.6/6.8 104-94/47
1 213TC 1.15 208-230 82 F F 33.8-31 38.5-35.5 244-220
7 1/2
3 213TC 1.15 208-230/460 87.5 H L 19-17.2/8.6 21.7-19.6/9.8 169-152/76
1 213TC 1.15 230 85.5 F F 40 46 284

TM02 7696 3803


10
3 213TC 1.15 208-230/460 85.5 F J 25-24/12 28.3-27.2/13.6 233-210/105
15 3 254TC 1.15 208-230/460 86.5 H L 38-34/17 43.4-39/19.5 376-340/170
3 254TC 1.15 230/460 88.5 F K 46/23 52.4/26.2 420/210
20
3 284TSC 1.15 230/460 89.5 F H 46/23 52.4/26.2 320/160
25 3 284TSC 1.15 230/460 91.7 F J 57/28.5 66/33 498/249
30 3 286TSC 1.15 230/460 91 F G 68/34 78/39 450/225
40 3 286TSC 1.15 230/460 90.2 F H 90/45 104/52 644/322
50 3 326TSC 1.15 230/460 93 F G 110/55 128/64 746/393
60 3 364TSC 1.15 230/460 93 F G 134/67 154/77 918/459

Notes:
1. The information in this chart applies to Grundfos’
specified Baldor® motors.
Grundfos CR pumps are supplied with heavy-duty
2-pole, NEMA C-frame motors built or selected to our
rigid specifications. All CR pump motors have heavy-
duty bearings in them for maximum thrust require-
ments.
It is not recommended that an off-the-shelf standard
Baldor motor be used on a Grundfos pump. Ideally,
the best motor choice would be the Grundfos speci-
fied motor.
2. Other motor types are available (i.e., Explosion proof,
Mill and Chem duty, High Efficiency, etc.), consult lo-
cal Grundfos company for more information.
3. Pumps supplied by Grundfos Canada are normally
supplied with motors from other manufactures. 575
volt motors meet EPAct/NRC efficiency standards. Di-
mensions and data will vary, contact local Grundfos
company for more information.
4. All values are subject to change without notice.

51

You might also like