Innovators in Protection Technology

ow

n
o
P
e r D i s t r i b u ti

[CATALOGUE TB2-CAT]

TEMBREAK 2 Innovators in Protection Technology

MOULDED CASE CIRCUIT


BREAKERS
I N D U S T R I A L S W I T C H G E A R & A U T O M AT I O N S P E C I A L I S T S

Beyond the Standard ™

[1]
www.nhp.com.au www.nhp-nz.com
Innovators in Protection Technology

MOULDED CASE CIRCUIT BREAKERS

MAIN CONTACT / TOGGLE STATUS VISIBILITY

Simply.....

Beyond the
Standard ™
ON (I) OFF (O) TRIPPED

• Easy accessory
fitting

• Double insulated Opening force


is transmitted
Contacts
separated
Maintenance
can be
MCCB directly from
the toggle
performed on
the load side
switch

• 125 / 250 A
adjustment
flexibility

TemBreak 2 MCCBs are marked with the IEC symbol indicating Direct Opening Action.
• Clear contact The robust mechanism ensures that the force applied to the toggle is transmitted
status directly to the contacts.

• Symmetrical
design
Isolation and Machine Safety
• Elec / Mech Complies with direct action
contact status requirements.
endurance

• Low temperature
rise

• Higher harmonic
immunity

• High insulation
voltage
[2]
Innovators in Protection Technology

MOULDED CASE CIRCUIT BREAKERS

TEMBREAK 2 Simply flexible

Positive OFF/ON operation.


The toggle mechanism is directly driven by
the MCCB main contacts. The label logo
below indicates this fact.
Common internal
accessories 125 - 630 A

All internal and external


accessories are field
installable

Thermal Magnetic or
Electronic Trip units

Thermal Magnetic
125 A, 250 A and 400 A MCCBs
• MCCBs are fitted with adjustable thermal AND
adjustable magnetic current adjustment dials

Electronic MCCB range


• From 50 A to 630 A
• 2 frame sizes: 250 A and 400/630 A

[3]
Innovators in Protection Technology

MOULDED CASE CIRCUIT BREAKERS

ELECTRICAL CHARACTERISTICS

According to IEC 60947-2, EN 60947-2, JIS C 8201-2, AS/NZS 3947-2, NEMA

Quantity Units Condition


Maximum rated current In A 45/50 °C 125 160
Model E125 S125 H125 L125 S160 H160 L160
Number of poles 3, 4 1 3, 4 3, 4 3, 4 1 3, 4 3, 4 3, 4
Type NJ NF NJ GJ NJ NJ NF NJ GJ NJ NJ
Rated Breaking Icu kA 690 V AC - - 6 6 20 25 - 7.5 7.5 20 25
Capacity 440 V AC 15 - 25 50 85 125 - 25 50 85 125
380/415 V AC 25 25* 36 65 125 200 25* 36 65 125 200
220/240 V AC 35 25 50 85 150 200 25 65 85 150 200
250 V DC 25 - 25 40 40 40 - 40 40 40 40
Ics kA 690 V AC - - 6 6 15 20 - 7.5 7.5 15 20
440 V AC 12 - 25 25 65 100 - 25 25 65 100
380/415 V AC 19 13* 30 33 85 150 19* 36 36 85 150
220/240 V AC 27 13 50 85 150 150 19 65 85 150 150
250 V DC 19 - 19 40 40 40 - 40 40 40 40
Rated Breaking Capacity, kA 480 V AC 8 - 22 25 45 65 - 22 25 45 65
NEMA 240 V AC 35 25* 50 85 150 200 25 65 85 150 200

Outline Dimensions h mm 155 165 165 165 165


w mm 3 pole, (1 pole) 90, (30) 105 (35) 105 105
w mm 4 pole 120 140 140 140 140
d mm 68 103 68 103 103
Utilisation Category A A A A A A A A A A A
Available Protection Adjustable thermal, adjustable magnetic
Units Fixed thermal, fixed magnetic
Microprocessor

These characteristics are the same for all products


on this page.

Rated AC and DC insulation voltage Ui V 800


Rated impulse withstand voltage Uimp kV 8
Rated operational voltage Ue V AC 690
Suitable for isolation Yes
Direct opening action Yes
12 A to 125 A application

12 A to 250 A application
* Breaking capacity shown is at 1/√3 times the standard voltage.

TemBreak 2 switch-disconnectors are available with the same


frame dimensions as the MCCBs.

[4]
Innovators in Protection Technology

MOULDED CASE CIRCUIT BREAKERS

250 400 630


E250 S250 H250 L250 E400 S400 H400 L400 E630 S630
3, 4 3, 4 3, 4 3, 4 3, 4 3, 4 3, 4 3, 4 3, 4 3, 4
NJ NJ GJ PE NJ NJ NJ CJ NJ NE GJ GE NJ NE NJ NE NE CE GE
- 7.5 7.5 20 20 25 - 15 20 20 20 20 35 35 50 50 10 20 20
15 25 50 50 85 125 22 30 45 30 50 50 85 85 125 125 25 45 50
25 36 65 70 125 200 25 36 50 50 70 70 125 125 200 200 36 50 70
35 65 85 125 150 200 35 50 85 85 100 100 150 150 200 200 50 85 100
25 40 40 - 40 40 25 40 40 - 40 - 40 - 40 - - - -
- 7.5 7.5 15 15 20 - 15 15 15 15 15 35 35 50 50 10 15 15
12 25 25 50 65 100 22 30 45 45 45 45 65 65 100 100 25 45 45
19 36 36 70 85 150 25 36 50 50 50 50 85 85 150 150 36 50 50
27 65 85 125 150 150 35 50 85 85 85 85 150 150 150 150 50 85 85
19 40 40 - 40 40 19 40 40 - 40 - 40 - 40 - - - -
10 22 25 35 45 65 15 22 25 25 30 30 45 45 65 65 15 25 30
35 65 85 125 150 200 35 50 85 85 100 100 150 150 200 200 50 85 100

165 165 260 260


105 105 140 140
140 140 185 185
68 103 103 103
A A A A A A A A A A A A A A A A A A A

125 A to 630 A application

[5]
Innovators in Protection Technology

MOULDED CASE CIRCUIT BREAKERS

INTERNAL ACCESSORIES
One size fits all!

General purpose types

Auxiliary
Alarm

Heavy duty types

Auxiliary

Alarm

Shunt UVT

SMART ACCESSORIES

SIMPLY SAFE
• Common accessory range from 125AF to 630AF
• Double insulated MCCB allowing accessory fitting while “live”
• TemBreak 2 accessory types reduce part numbers, stock, make supply more customer friendly, reduce lead times
• All accessories meet IEC 60 947-5, AS/NZS 3947-5
• Endurance tested accessories - not normally done by many manufacturers

[6]
Innovators in Protection Technology

MOULDED CASE CIRCUIT BREAKERS

EXTERNAL ACCESSORIES
Simple to fit

TemPlug
A simple plug in method for
MCCBs 125 A to 630 A

Motor fitting
Transfer switch Transfer switch Simple, quick installation in
Link interlock Wire interlock seconds requiring no tools
on 125 A / 250 A MCCBs.
Allows for handles and Horizontal, vertical or diagonal Larger MCCBs only require
motors to be mounted MCCB mounting allows for handles a screwdriver
and motors to be mounted

Variable and fixed depth


handles
Terminal covers Plug in MCCB
Simple, quick installation in
seconds requiring no tools on 125 Slide-on and click into Safety interlock standard to
A / 250 A MCCBs. Larger MCCBs place, no tools required maximise safety
only require a screwdriver. IP 54
or IP 65 handles [7]
Innovators in Protection Technology

AUSTRALIA
www.nhp.com.au
VICTORIA NEW SOUTH WALES
MELBOURNE HEADQUARTERS SYDNEY
43-67 River Street 30-34 Day Street North
Richmond Victoria 3121 Silverwater New South Wales 2128
Telephone +61 3 9429 2999 Telephone +61 2 9748 3444
Fax +61 3 9429 1075 Fax +61 2 9648 4353
Email mel-sales@nhp.com.au Email syd-branch@nhp.com.au

NATIONAL DISTRIBUTION AND NEWCASTLE


MANUFACTURING CENTRE 575 Maitland Road
104-106 William Angliss Drive Mayfield West New South Wales 230
Laverton North Victoria 3026 Telephone +61 2 4960 2220
Telephone +61 3 9429 2999 Fax +61 2 4960 2203
Fax +61 3 9368 2997 Email ncl-branch@nhp.com.au
Email mel-sales@nhp.com.au
SOUTH AUSTRALIA
TASMANIA ADELAIDE
HOBART 36-38 Croydon Road
2/65 Albert Road Keswick South Australia 5035
Moonah Tasmania 7009 Telephone +61 8 8297 9055
Telephone +61 3 6228 9575 Fax +61 8 8371 0962
Fax +61 3 6228 9757 Email adl-branch@nhp.com.au
Email tas-sales@nhp.com.au
WESTERN AUSTRALIA
QUEENSLAND PERTH
BRISBANE 38 Belmont Ave
16 Riverview Place Rivervale Western Australia 6103
Murarrie Queensland 4172 Telephone +61 8 9277 1777
Telephone +61 7 3909 4999 Fax +61 8 9277 1700
Fax +61 7 3399 9712 Email per-branch@nhp.com.au
Email bris-branch@nhp.com.au
NORTHERN TERRITORY
TOWNSVILLE DARWIN
62 Leyland Street 3 Steele Street
Garbutt Queensland 4814 Winnellie Northern Territory 0820
Telephone +61 7 4779 0700 Telephone +61 8 8947 2666
Fax +61 7 4775 1457 Fax +61 8 8947 2049
Email tsv-branch@nhp.com.au Email dar-branch@nhp.com.au

ROCKHAMPTON
14 Robison Street
Rockhampton Queensland 4701
Telephone +61 7 4927 2277
Fax +61 7 4922 2947 NEW ZEALAND
Email rkh-branch@nhp.com.au www.nhp-nz.com
TOOWOOMBA AUCKLAND
Cnr Carroll St & Struan Crt 7 Lockhart Place
Toowoomba Queensland 4350 Mt Wellington Auckland
Telephone +61 7 4634 4799 Telephone +64 9 276 1967
Fax +61 7 4633 1796 Fax +64 9 276 1992
Email too-branch@nhp.com.au Email sales@nhp-nz.com

CAIRNS CHRISTCHURCH
2/1 Bramp Close 85 Gasson Street
Portsmith Queensland 4870 Sydenham Christchurch
Telephone +61 7 4035 6888 Telephone +64 3 377 4407
Fax +61 7 4035 6999 Fax +64 3 377 4405
Email cns-branch@nhp.com.au Email sales@nhp-nz.com

E L E C T R I C A L E N G I N E E R I N G P R O D U C T S P T Y LT D A.B.N 84 0 0 4 3 0 4 8 1 2

Catalogue - TB2-CAT 09/06


© Copyright NHP 2006

You might also like